ALLEN-BRADLEY 440P

Position Interlock Switches
Safety Limit Switches
Imp
Specifications
Standards
Category
Approvals
Imp 1
Imp 2
NRTL/C
Description
The Imp offers safety switch performance of bigger units in the
most compact case available. Designed with two mounting hole
options and a choice of actuator positions, the Imp will fit in the
most confined spaces.
Guardmaster limit switches can be used in other applications other
than guard doors, for example on moving machine beds, crane arms,
etc.
Operation of these limit switches is achieved by the sliding action of
the guard or other moving object deflecting the plunger or lever. It is
important that upon actuation, the guard or other moving objects
should not pass completely over the switch and allow the plunger or
lever to return to its original position.
Features
• Positive operation, forced disconnection of contacts
• Contacts, 1 N.C. & 1 N.O.
7-18
Safety Contacts
Utilization Category
AC (Ue)
(le)
DC
Max. Switched Current/
Voltage/Load
Thermal Current (lth)
Minimum Current
Safety Contact Gap
Rtd. Insulation Voltage
Rtd. Impulse Withstand
Voltage
Auxiliary Contacts
Pollution Degree
Actuator Travel for Positive
Opening
Break Contact Min. Force
Maximum Actuator Travel
Maximum Actuation Speed
Max. Actuation Frequency
Case Material
Actuator Material
Protection
Conduit Entry
Operating Temperature
Mounting
Mechanical Life
Electrical Life
Colour
EN954-1, ISO13849-1, IEC/EN60204-1,
NFPA79, EN1088, ISO14119, IEC/
EN60947-5-1, ANSI B11.19, AS4024.1
Cat. 1 Device per EN954-1
Dual channel interlocks suitable for Cat.
3 or 4 systems
CE marked for all applicable directives
and CSA NRTL/C
1 N.C. positive break
AC 15
500V 250V 100V
1A 2A
5A
250V 0.5A, 24V 2A
500V/500VA
10A
5V 5mA DC
>2 x 2mm (0.079in)
(Ui) 500V
(Uimp) 2500V
1 N.O.
3
2.5mm (0.098in)
10N (2.25lb)
5mm (0.197in)
160mm (6.29in) per sec
2 Cycle per sec
UL approved glass filled polyester
Acetal
IP30
3x break-outs
-25°C to +80°C (-13°F to +176°F)
2 x M3 front or 2 x M4 top
10,000,000 operations
1,000,000 operations
Red
Position Interlock Switches
Safety Limit Switches
Imp
Product Selection
Contact Action
Operator Type
Top Push
Roller
Top Push
Cross
Roller
Contact Open
Contact
Slow
break
before
make
1 N.O.
& 1 N.C.
Contact Closed
0mm 1
11/12
Conduit
5
3x breakouts
23/24
2.5
Type
Catalogue
Number
Imp 1
(roller parallel
to switch front)
440P-M18001
Imp 2
(roller perpendicular
to switch front)
440P-M18002
Dimensions—mm (inches)
10.3 (0.41)
Ø11 (0.43)
2.4 (0.09)
2xM3
5mm Roller Travel
20
(0.79)
37.7 (1.48)
4 (0.16)
54 (2.13)
2xM4
15
(0.59)
4
(0.16)
15.2
(0.6)
25 (0.98)
23.3 (0.92)
Connections
11
12
23
24
1 N.O. & 1 N.C.
7-19