TI DS100DF410SQE

DS100DF410
www.ti.com
SNLS399A – JANUARY 2012 – REVISED FEBRUARY 2013
DS100DF410 Low Power 10GbE Quad Channel Retimer
Check for Samples: DS100DF410
FEATURES
APPLICATIONS
•
•
1
2
•
•
•
•
•
•
•
•
•
•
•
•
•
•
Each channel independently locks to 10.3125
Gbps
Lock operation (typically under 15 ms)
Low latency (~300 ps)
Adaptive equalization up to 34 dB boost at 5
GHz
Adjustable transmit VOD : 600 to 1300 mVp-p
Adjustable transmit de-emphasis to -12 dB
Typical Power Dissipation (EQ+DFE+CDR+DE):
180 mW / channel
Programmable output polarity inversion
Input signal detection, CDR lock
detection/indicator
On-chip Eye Monitor (EOM), PRBS generator
Single 2.5 V ±5% power supply
SMBus/EEPROM configuration modes
Operating temperature range of -40 to 85°C
RHS 48-pin, 7 mm x 7 mm package
Easy pin compatible upgrade between
repeater and retimers
– DS100RT410 (EQ+CDR+DE): 10.3125 Gbps
– DS100DF410 (EQ+DFE+CDR+DE): 10.3125
Gbps
– DS110RT410 (EQ+CDR+DE): 8.5 - 11.3 Gbps
– DS110DF410 (EQ+DFE+CDR+DE): 8.5 - 11.3
Gbps
– DS125RT410 (EQ+CDR+DE): 9.8 - 12.5 Gbps
– DS125DF410 (EQ+DFE+CDR+DE): 9.8 - 12.5
Gbps
– DS100BR410 (EQ+DE): Up to 10.3125 Gbps
•
•
Front port SFF 8431 (SFP+) optical and direct
attach copper
Backplane reach extension, data retimer
Ethernet: 10GbE, 1GbE
For other data rates and data transmission
protocols, other pin-compatible devices in the
retimer family can be used.
DESCRIPTION
The DS100DF410 is four channel retimers with
integrated signal conditioning. Each channel can
independently lock to 10.3125 Gbps data rate to
support 10GbE. The device includes a fully adaptive
Continuous-Time Linear Equalizer (CTLE), Clock and
Data Recovery (CDR) and transmit De-Emphasis
(DE) driver. The DS100DF410 also includes a self
calibrating 5-tap Decision Feedback Equalizer (DFE)
to enable data transmission over long, lossy and
crosstalk-impaired highspeed serial links to achieve
BER < 1×10-15.
The programmable settings can be applied easily
using the SMBus (I2C) interface, or they can be
loaded via an external EEPROM. An on-chip eye
monitor and a PRBS generator allow real-time
measurement of high-speed serial data for system
bring-up or field tuning. Flow-through pinout and
single power supply make the DS100DF410 easy to
use.
The device is offered in a RHS 48-pin, 7 mm x 7 mm
package with flow-through pinout for the high speed
signals.
1
2
Please be aware that an important notice concerning availability, standard warranty, and use in critical applications of
Texas Instruments semiconductor products and disclaimers thereto appears at the end of this data sheet.
All trademarks are the property of their respective owners.
PRODUCTION DATA information is current as of publication date.
Products conform to specifications per the terms of the Texas
Instruments standard warranty. Production processing does not
necessarily include testing of all parameters.
Copyright © 2012–2013, Texas Instruments Incorporated
DS100DF410
SNLS399A – JANUARY 2012 – REVISED FEBRUARY 2013
www.ti.com
TYPICAL APPLICATION DIAGRAM
Line Card
Switch Fabric
Optical Modules
DS100DF410
x4
DS100DF410
ASIC
x4
Connector
DS100DF410
x4
ASIC
SFP+(SFF8431)
QSFP
10GbE
x4
10GbE
Back
Plane/
DS100DF410
Passive Copper
Mid
Plane
Clean Signal
2
Submit Documentation Feedback
Noisy Signal
Copyright © 2012–2013, Texas Instruments Incorporated
Product Folder Links: DS100DF410
DS100DF410
www.ti.com
SNLS399A – JANUARY 2012 – REVISED FEBRUARY 2013
VDD
LOCK_0/ADDR_0
READ_EN
INT
REFCLK_OUT
ALL_DONE
LOCK_1/ADDR_1
GND
LP F_CP_ 1
LP F_REF_1
45
44
43
42
41
40
39
38
37
LP F_CP_ 0
47
46
LP F_REF_0
48
Connection Diagram
RXP0
1
36
TXP0
RXN0
2
35
TXN0
VDD
3
34
GND
RXP1
4
33
TXP1
RXN1
5
32
TXN1
VDD
6
31
GND
VDD
7
7 mm x 7 mm, 0.5 mm pitch
30
GND
RXP2
8
TOP VIEW
29
TXP2
RXN2
9
DAP = GND
28
TXN2
VDD
10
27
GND
RXP3
11
26
TXP3
RXN3
12
25
TXN3
13
14
15
16
17
18
19
20
21
22
23
24
LP F_REF_3
LP F_CP_ 3
VDD
LOCK_3ADDR_3
SDC
SDA
REFCLK_IN
EN_SMB
LOCK_2/ADDR_2
GND
LP F_CP_ 2
LP F_REF_2
DS100DF410
Submit Documentation Feedback
Copyright © 2012–2013, Texas Instruments Incorporated
Product Folder Links: DS100DF410
3
DS100DF410
SNLS399A – JANUARY 2012 – REVISED FEBRUARY 2013
www.ti.com
Pin Descriptions
Pin Name
I/O, Type (1)
Pin #
Description
HIGH-SPEED DIFFERENTIAL I/O
RXP0
RXN0
1
2
I, CML
Inverting and non-inverting CML-compatible differential inputs to the equalizer.
Nominal differential input impedance = 100Ω.
RXP1
RXN1
4
5
I, CML
Inverting and non-inverting CML-compatible differential inputs to the equalizer.
Nominal differential input impedance = 100Ω.
RXP2
RXN2
8
9
I, CML
Inverting and non-inverting CML-compatible differential inputs to the equalizer.
Nominal differential input impedance = 100Ω.
RXP3
RXN3
11
12
I, CML
Inverting and non-inverting CML-compatible differential inputs to the equalizer.
Nominal differential input impedance = 100Ω.
TXP0
TXN0
36
35
O, CML
Inverting and non-inverting CML-compatible differential outputs from the driver.
Nominal differential output impedance = 100Ω.
TXP1
TXN1
33
32
O, CML
Inverting and non-inverting CML-compatible differential outputs from the driver.
Nominal differential output impedance = 100Ω.
TXP2
TXN2
29
28
O, CML
Inverting and non-inverting CML-compatible differential outputs from the driver.
Nominal differential output impedance = 100Ω.
TXP3
TXN3
26
25
O, CML
Inverting and non-inverting CML-compatible differential outputs from the driver.
Nominal differential output impedance = 100Ω.
LOOP FILTER CONNECTION PINS
LPF_CP_0
LPF_REF_0
47
48
I/O, analog
Loop filter connection
Place a 22 nF ± 10% Capacitor between LPF_CP_0 and LPF_REF_0
LPF_CP_1
LPF_REF_1
38
37
I/O, analog
Loop filter connection
Place a 22 nF ± 10% Capacitor between LPF_CP_1 and LPF_REF_1
LPF_CP_2
LPF_REF_2
23
24
I/O, analog
Loop filter connection
Place a 22 nF ± 10% Capacitor between LPF_CP_2 and LPF_REF_2
LPF_CP_3
LPF_REF_3
14
13
I/O, analog
Loop filter connection
Place a 22 nF ± 10% Capacitor between LPF_CP_3 and LPF_REF_3
REFCLK_IN
19
I, 2.5V analog
Input is 2.5 V, 25 MHz ± 100 ppm reference clock from external oscillator
No stringent phase noise requirement
REFCLK_OUT
42
O, 2.5V analog
Output is 2.5 V, buffered replica of reference clock input for connecting multiple
DS100DF410s on a board
45
40
21
16
O, 2.5V
LVCMOS
Output is 2.5 V, the pin is high when CDR lock is attained on the corresponding
channel
Note that these pins are shared with SMBus address strap input functions read
at startup.
REFERENCE CLOCK I/O
LOCK INDICATOR PINS
LOCK_0
LOCK_1
LOCK_2
LOCK_3
SMBus MASTER MODE PINS
ALL_DONE
41
O, 2.5V
LVCMOS
Output is 2.5 V, the pin goes low to indicate that the SMBus master EEPROM
read has been completed.
READ_EN
44
I, 2.5V
LVCMOS
Input is 2.5 V, a transition from high to low starts the load from the external
EEPROM. The READ_EN pin must be tied low when in SMBus slave mode
INTERRUPT OUTPUT
INT
43
O, 3.3V
Used to signal horizontal or vertical eye opening out of tolerance, loss of signal
LVCMOS, Open detect, or CDR unlock
Drain
External 2KΩ to 5KΩ pull-up resistor is required.
Pin is 3.3 V LVCMOS tolerant.
SERIAL MANAGEMENT BUS (SMBus) INTERFACE
EN_SMB
(1)
4
20
I, 2.5V analog
Input is 2.5 V, selects SMBus master mode or SMBus slave mode
EN_SMB = High for slave mode
EN_SMB = Float for master mode
Tie READ_EN pin low for SMBus slave mode. See Table 1
Notes:
I = Input, O = Output and 2.5V LVCMOS pins are 2.5 V levels only.
Only SMBus pins SDA and SDC and INT pin are 3.3 V tolerant. These three pins are open-drain and require external pull-up
resistors.
Submit Documentation Feedback
Copyright © 2012–2013, Texas Instruments Incorporated
Product Folder Links: DS100DF410
DS100DF410
www.ti.com
SNLS399A – JANUARY 2012 – REVISED FEBRUARY 2013
Pin Descriptions (continued)
Pin Name
I/O, Type (1)
Pin #
Description
SDA
18
I/O, 3.3V
Data Input / Open Drain Output
LVCMOS, Open External 2KΩ to 5KΩ pull-up resistor is required.
Drain
Pin is 3.3 V LVCMOS tolerant.
SDC
17
I/O, 3.3V
Clock Input / Open Drain Clock Output
LVCMOS, Open External 2KΩ to 5KΩ pull-up resistor is required.
Drain
Pin is 3.3 V LVCMOS tolerant.
ADDR_0
ADDR_1
ADDR_2
ADDR_3
45
40
21
16
I, 2.5V
LVCMOS
VDD
3, 6, 7,
10, 15, 46
Power
VDD = 2.5 V ± 5%
GND
22, 27,
30, 31,
34, 39
Power
Ground reference.
DAP
PAD
Power
Ground reference. The exposed pad at the center of the package must be
connected to ground plane of the board with at least 4 vias to lower the ground
impedance and improve the thermal performance of the package.
Input is 2.5 V, the ADDR_[3:0] pins set the SMBus address for the retimer.
These pins are strap inputs. Their state is read on power-up to set the SMBus
address in SMBus control mode.
High = 1KΩ to VDD, Low = 1KΩ to GND
Note that these pins are shared with the lock indicator functions. See Table 2
POWER
These devices have limited built-in ESD protection. The leads should be shorted together or the device placed in conductive foam
during storage or handling to prevent electrostatic damage to the MOS gates.
Absolute Maximum Ratings
(1)
Supply Voltage (VDD)
-0.5V to +2.75V
2.5 I/O Voltage
(LVCMOS and Analog)
-0.5V to +2.75V
3.3 LVCMOS I/O Voltage
(SDA, SDC, INT)
-0.5V to +4.0V
Signal Input Voltage (RXPn, RXNn)
-0.5V to +2.75V
Signal Output Voltage (TXPn, TXNn)
-0.5V to +2.75V
Junction Temperature
+150°C
Storage Temperature
ESD Rating
-65°C to +150°C
HBM, STD - JESD22-A114F
≥6 kV
MM, STD - JESD22-A115-A
≥250 V
≥1250 V
CDM, STD - JESD22-C101-D
Thermal Resistance
θJA, No Airflow,
4 layer JEDEC, 9 thermal vias
26.1 °C/W
For soldering specifications: see http://www.ti.com/lit/an/snoa549c/snoa549c.pdf
(1)
“Absolute Maximum Ratings” indicate limits beyond which damage to the device may occur, including inoperability and degradation of
device reliability and/or performance. Functional operation of the device and/or non-degradation at the Absolute Maximum Ratings or
other conditions beyond those indicated in the Recommended Operating Conditions is not implied.
Recommended Operating Conditions (1)
Supply Voltage (VDD to GND)
Ambient Temperature
(1)
Min
Typ
Max
Units
2.375
2.5
2.625
V
-40
25
+85
°C
The Recommended Operating Conditions indicate conditions at which the device is functional and the device should not be operated
outside these conditions.
Submit Documentation Feedback
Copyright © 2012–2013, Texas Instruments Incorporated
Product Folder Links: DS100DF410
5
DS100DF410
SNLS399A – JANUARY 2012 – REVISED FEBRUARY 2013
www.ti.com
Electrical Characteristics
Over recommended operating supply and temperature ranges with default register settings unless otherwise specified.
Symbol
Parameter
Conditions
Min
Typ
Max
(1)
Units
POWER
PD
Power Supply Consumption
NTPS
Supply Noise Tolerance
(4)
Average Power Consumption (2)
720
Max Transient Power Supply
Current (3)
500
50 Hz to 100 Hz
100
mVP-P
100 Hz to 10 MHz
40
mVP-P
10 MHz to 5.0 GHz
10
mVP-P
mW
610
mA
2.5V LVCMOS DC SPECIFICATIONS
VIH
High Level Input Voltage
1.75
VDD
V
VIL
Low Level Input Voltage
GND
0.7
V
VOH
High Level Output Voltage
IOH = -3mA
VOL
Low Level Output Voltage
IOL = 3mA
0.4
V
IIN
Input Leakage Current
VIN = VDD
+10
μA
VIN = GND
2.0
V
μA
-10
IIH
Input High Current (EN_SMB pin)
VIN = VDD
+55
μA
IIL
Input Low Current (EN_SMB pin)
VIN = GND
-110
μA
3.3 V LVCMOS DC SPECIFICATIONS (SDA, SDC, INT)
VIH
High Level Input Voltage
VDD = 2.5 V
1.75
3.6
V
VIL
Low Level Input Voltage
VDD = 2.5 V
GND
0.7
V
VOL
Low Level Output Voltage
IPULLUP = 3mA
IIH
Input High Current
VIN = 3.6 V, VDD = 2.5 V
IIL
Input Low Current
VIN = GND, VDD = 2.5 V
fSDC
SMBus clock rate
0.4
V
+20
+40
μA
-10
+10
μA
10
400
KHz
10.3125 Gbps Ethernet
10.1
10.6
Gbps
1.25 Gbps Ethernet
1.2
1.3
Gbps
DATA BIT RATES
RB
Bit Rate Range
SIGNAL DETECT
SDH
Signal Detect ON Threshold Level
Default differential input signal level
to assert signal detect, 10.3125
Gbps, PRBS-31
70
mVp-p
SDL
Signal Detect OFF Threshold Level Default differential input signal level
to de-assert signal detect, 10.3125
Gbps, PRBS-31
10
mVp-p
(1)
(2)
(3)
(4)
6
Typical values represent most likely parametric norms at VDD = 2.5V, TA = 25°C., and at the Recommended Operation Conditions at the
time of product characterization.
VDD= 2.5V, TA = 25°C. All four channels active and locked. DFE powered-up and enabled.
Maximum power supply current during lock acquisition. All four channels active, all four channels unlocked, all registers at default
settings.
Allowed supply noise (mVP-P sine wave) under typical conditions.
Submit Documentation Feedback
Copyright © 2012–2013, Texas Instruments Incorporated
Product Folder Links: DS100DF410
DS100DF410
www.ti.com
SNLS399A – JANUARY 2012 – REVISED FEBRUARY 2013
Electrical Characteristics (continued)
Over recommended operating supply and temperature ranges with default register settings unless otherwise specified. (1)
Symbol
Parameter
Conditions
Min
Typ
Max
Units
RECEIVER INPUTS (RXPn, RXNn)
VTX2, min
Minimum Source Transmit Launch
Signal Level (IN, diff)
See
(5)
VTX2, max
Maximum Source Transmit Launch
Signal Level (IN, diff)
See
(5)
VTX1, max
Maximum Source Transmit Launch
Signal Level (IN, diff)
See
(6)
VTX0, max
Maximum Source Transmit Launch
Signal Level (IN, diff)
See
(7)
600
mVP-P
1000
mVP-P
1200
mVP-P
1600
mVP-P
-15
dB
(8)
LRI
Maximum Differential Input Return
Loss - |SDD11|
100 MHz – 6 GHz
ZD
Differential Input Impedance
100 MHz – 6 GHz
100
Ω
ZS
Single-ended Input Impedance
100 MHz – 6 GHz
50
Ω
DRIVER OUTPUTS (TXPn, TXNn)
VOD0
VOD7
VOD_DE
tR, tF
LRO
tDP
TDE
Differential output voltage
Differential output voltage
De-emphasis level
(9)
Transition time (rise and fall
times) (9) (10)
Maximum Differential Output
Return Loss - |SDD22|
Propagation Delay
De-emphasis pulse duration
Differential measurement with
OUT+ and OUT- terminated by
50Ω to GND, AC-Coupled,
SMBus register VOD control
(Register 0x2d bits 2:0) set to 0,
minimum VOD
De-emphasis control set to
minimum (0 dB)
400
Differential measurement with
OUT+ and OUT- terminated by
50Ω to GND, AC-Coupled
SMBus register VOD control
(Register 0x2d bits 2:0) set to 7,
maximum VOD
De-emphasis control set to
minimum (0 dB)
1000
mVP-P
mVP-P
Differential measurement with
OUT+ and OUT- terminated by
50Ω to GND, AC-Coupled
Set by SMBus register control to
maximum de-emphasis setting
Relative to the nominal 0 dB deemphasis level set at the minimum
de-emphasis setting
-12
dB
Transition time control = Full Slew
Rate
39
ps
Transition time control = Limited
Slew Rate
50
ps
-15
dB
300
ps
75
ps
100 MHz – 6 GHz
Retimed data
(12)
675
(8)
(11)
Measured at VOD = 1000 mVP-P,
de-emphasis setting = -12 dB
Differential signal amplitude at the transmitter output providing < 1x10-12 bit error rate. Measured at 10.3125 Gbps with a PRBS-31 data
pattern. Input transmission channel is 40-inch long FR-4 stripline, 4-mil trace width.
(6) Differential signal amplitude at the transmitter output providing < 1x10-12 bit error rate. Measured at 10.3125 Gbps with a PRBS-31 data
pattern. Input transmission channel is 30-inch long FR-4 stripline, 4-mil trace width.
(7) Differential signal amplitude at the transmitter output providing < 1x10-12 bit error rate. Measured at 10.3125 Gbps with a PRBS-31 data
pattern. No input transmission channel.
(8) Measured with 10 MHz clock pattern output.
(9) Measured with clock-like {11111 00000} pattern.
(10) Slew rate is controlled by SMBus register settings.
(11) Typical at 10.3125 Gbps bit rate.
(12) De-emphasis pulse width varies with VOD and de-emphasis settings.
(5)
Submit Documentation Feedback
Copyright © 2012–2013, Texas Instruments Incorporated
Product Folder Links: DS100DF410
7
DS100DF410
SNLS399A – JANUARY 2012 – REVISED FEBRUARY 2013
www.ti.com
Electrical Characteristics (continued)
Over recommended operating supply and temperature ranges with default register settings unless otherwise specified. (1)
Symbol
Parameter
Conditions
-12 (13)
Min
Typ
Max
Units
TJ
Output total jitter
Measured at BER = 10
10
ps
TSKEW
Intra Pair Skew
Difference in 50% crossing
between TXPn and TXNn for any
output
3
ps
5
MHz
0.6
UI
-6
dB
15
ms
CLOCK AND DATA RECOVERY
BWPLL
PLL Bandwidth
-3 dB
Measured at 10.3125 Gbps
JTOL
Input sinusoidal jitter tolerance
10 kHz to 250 MHz sinusoidal jitter
frequency
Measured at BER = 10-15
Jitter Transfer
Sinusoidal jitter at 10 MHz jitter
frequency
Measured at BER = 10-15
CDR Lock Time
Measured at 10.3125 Gbps
JTRANS
TLOCK
(13) Typical with no output de-emphasis, minimum output transmission channel.
8
Submit Documentation Feedback
Copyright © 2012–2013, Texas Instruments Incorporated
Product Folder Links: DS100DF410
DS100DF410
www.ti.com
SNLS399A – JANUARY 2012 – REVISED FEBRUARY 2013
FUNCTIONAL DESCRIPTION
The DS100DF410 is a low-power 10GbE 4-channel retimer. Each of the four channels operates independently.
Each channel includes a Continuous-Time Linear Equalizer (CTLE) which compensates for the presence of a
dispersive transmission channel between the source and the DS100DF410's input.
Each channel of the DS100DF410 also includes a five-tap Decision Feedback Equalizer (DFE). This is a
nonlinear, symbol-spaced adaptive equalizer which compensates for signal impairments that are not properly
compensated by the CTLE. The DFE provides improved compensation for crosstalk and inter-symbol
interference (ISI).
Each channel includes an independent Voltage-Controlled Oscillator (VCO) and Phase-Locked Loop (PLL) which
produce a clean clock. The clean clock produced by the VCO and the PLL is phase-locked to the incoming data
clock, but the high-frequency jitter on the incoming data is attenuated by the PLL, producing a clean clock with
substantially reduced jitter. This clean clock is used to retime the incoming data, removing high-frequency jitter
from the data stream and producing a data output signal with reduced jitter.
Each channel of the DS100DF410 features an output driver with settable differential output voltage and settable
output de-emphasis. The output de-emphasis compensates for dispersion in the transmission channel at the
output of the DS100DF410.
These three functions together make up the data path for the DS100DF410.
EQ
OUTBUF
Retimer
IN_n+
OUT_n+
IN_n-
OUT_n100
SMBus
100
CDR
SMBus
Signal
Detect
SDC
SDA
EN_SMB
REF_CLK_IN
LOCK
SMBus
Figure 1. DS100DF410 Data Path Block Diagram — One of Four Channels
Device Data Path Operation
The data path operation of the DS100DF410 comprises three functional sections as shown in the data path block
diagram of Figure 1. The three functional sections are as follows.
• Channel Equalization
• Clock and Data Recovery
• Output Driver
Channel Equalization
Physical transmission media such as traces on printed circuit boards (PCBs) or copper cables exhibit a low-pass
frequency response characteristic. The magnitude of the high-frequency loss varies with the length of the
transmission media and with the loss of the materials which comprise it. This differential high-frequency loss and
the frequency-dependent group delay of the transmission media introduce inter-symbol interference in the highspeed broadband signals propagating through the transmission media.
The DS100DF410 applies a frequency-response equalization function to the incoming data stream. The
equalization function reduces the effect of the frequency-dependent loss in the transmission media between the
transmitter output and the input of the DS100DF410. The DS100DF410 includes a Continuous Time Linear
Equalizer or CTLE. The CTLE is designed to provide a controlled-amount of high-frequency boost to the signal in
the frequency domain to compensate for the frequency-dependent loss in the transmission media.
Submit Documentation Feedback
Copyright © 2012–2013, Texas Instruments Incorporated
Product Folder Links: DS100DF410
9
DS100DF410
SNLS399A – JANUARY 2012 – REVISED FEBRUARY 2013
www.ti.com
The CTLE is a four-stage variable boost high-gain amplifier with a quasi-high-pass characteristic. Each of the
four stages can be set to provide various amounts of high-frequency boost with the overall transfer function of
the CTLE set by the cascade of all four sections. The high-frequency boost of each CTLE stage is variable. The
optimum boost for each stage is one that causes the transfer function magnitude of the transmission channel and
the CTLE in cascade to be flat over a band of frequencies extending up to half the data rate which is commonly
referred to as the “Nyquist” frequency. In normal operation, the DS100DF410 sets the boost of the CTLE
automatically to approximate the optimum cascaded response.
In addition to the CTLE, the DS100DF410 includes a clock-based Decision-Feedback Equalizer or DFE. The
DFE operates as a symbol-spaced, discrete-time, nonlinear analog filter which provides additional discrimination
against signal impairments, both those arising from the dispersive transmission channel between the transmitter
and the DS100DF410 and those arising from noise in the system and crosstalk between transmission channels.
The DFE introduces an analog summing node between the CTLE output and the comparator, which makes the
“decision” whether the current bit is a 1 or a 0. At this summing node scaled versions of the previous five
decision results (bits) are added in an analog fashion to the input signal at the summing node, and the output of
the summing node is the input to the comparator. This is a well-known type of discrete-time nonlinear adaptive
filter.
The scaling or tap weight and the algebraic sign of each of the five taps of the DFE are variable. In normal
operation the DS100DF410 sets the tap weights and polarities automatically to approximate the optimum noiseand crosstalk-free response.
Clock and Data Recovery
The DS100DF410 performs its clock and data recovery function by detecting the bit transitions in the incoming
data stream and locking its internal VCO to the clock represented by the mean arrival times of these bit
transitions. This process produces a recovered clock with jitter which is greatly reduced for jitter frequencies
outside the bandwidth of the CDR Phase-Locked Loop (PLL). This is the primary benefit of using the
DS100DF410 in a system. It significantly reduces the jitter present in the data stream, in effect resetting the jitter
budget for the system.
10
Submit Documentation Feedback
Copyright © 2012–2013, Texas Instruments Incorporated
Product Folder Links: DS100DF410
DS100DF410
www.ti.com
SNLS399A – JANUARY 2012 – REVISED FEBRUARY 2013
Output Driver
Once the input data has been retimed by the DS100DF410 to the recovered, cleaned, clock, it is output to the
next device in the signal path using the output driver. The DS100DF410 is commonly used in applications where
lossy transmission media exist both at the input and the output of the DS100DF410. The CTLE and the DFE
compensate for lossy transmission media at the input to the DS100DF410. The output de-emphasis
compensates for the lossy transmission media at the output of the DS100DF410.
When there is a transition in the output data stream, the output differential voltage reaches its configured
maximum value within the configured rise/fall time of the output driver. Following this, the differential voltage
rapidly falls off until it reaches the configured VOD level minus the configured de-emphasis level. This “predistortion” of the output signal accentuates the high-frequency components of the output signal at the expense of
the low-frequency components. The pre-distorted signal, with its high-frequency components emphasized relative
to its low-frequency components, travels down the dispersive transmission media at the output of the
DS100DF410 with less inter-symbol interference than an undistorted signal would exhibit.
The output driver is capable of driving variable output voltages with variable amounts of analog de-emphasis.
The output voltage and de-emphasis level can be configured by writing registers over the SMBus. The
DS100DF410 cannot determine independently the appropriate output voltage or de-emphasis setting, so the user
is responsible for configuring these parameters. They can be set for each channel independently.
An idealized transmit waveform with analog de-emphasis applied is shown in Figure 2.
1.0
VOD (V)
0.5
0.0
-0.5
-1.0
0
1
2
3
4 5 6
TIME (UI)
7
8
9 10
Figure 2. Idealized De-Emphasis Waveform
Submit Documentation Feedback
Copyright © 2012–2013, Texas Instruments Incorporated
Product Folder Links: DS100DF410
11
DS100DF410
SNLS399A – JANUARY 2012 – REVISED FEBRUARY 2013
www.ti.com
DEVICE CONFIGURATION INFORMATION
The DS100DF410 can be configured by the user to optimize its operation. The four channels can be optimized
independently in SMBus master or SMBus slave mode. The operational settings available for user configuration
include the following.
• CTLE boost setting
• DFE tap weight and polarity setting
• Driver output voltage
• Driver output de-emphasis
• Driver output rise/fall time
Configuration of the DS100DF410 is accomplished by writing the appropriate values into various device registers
over the SMBus. This can either be done while the device is operating or upon initial power-up. When the
DS100DF410 is operating it behaves like an SMBus slave device, and its register contents can be read or written
over the SMBus. Optionally, when the DS100DF410 first powers up, it can behave like an SMBus master and
read its register contents autonomously from an external EEPROM.
CTLE Boost Setting
The CTLE is a four-stage amplifier with an adjustable, quasi-high-pass transfer function on each stage. The
overall frequency response of the CTLE is set by adjusting the boost of each stage independently. Each stage of
the CTLE can be set to one of four boost settings. The amount of high-frequency boost supplied by each stage
generally increases with increasing boost settings.
The CTLE can also be configured to adapt automatically to provide the optimum boost level for its input signal.
Automatic adaptation of the CTLE only is the default mode of operation for the DS100DF410.
DFE Tap Weight and Polarity Setting
The DS100DF410 includes a five-tap decision-feedback equalizer (DFE) which operates on the signal at the
output of the CTLE.
When the tap weights and polarities are properly set, the DFE approximates a matched filter for the input
transmission channel frequency response as modified by the CTLE frequency response. The CTLE and the DFE
work together to compensate for the input transmission channel response.
The DFE discriminates against input noise and random jitter as well as against crosstalk at the input to the
DS100DF410. When the DFE tap weights and polarities are properly set the DS100DF410 CDR operates at an
acceptable BER with more severe channel impairments than can be compensated with the CTLE alone.
It is possible to automatically or manually set the tap weights and polarities in the DS100DF410. Determining the
correct tap weights manually is difficult and time-consuming. The DS100DF410 automatically adapts the DFE tap
weights and polarities in normal operation. This automatic adaptation provides superior BER performance for
noisy channels and channels subject to crosstalk aggressors.
The DFE is powered down by default. In order for the DFE tap weights and polarities to be applied to the input
signal, bit 3 of register 0x1e, the dfe_PD bit, should be set to 0 to power up the DFE. Also the adapt mode
setting in register 0x31, bits[6:5] should be set to 2b'10 or 2b'11 so the device can automatically adapt the CTLE
and DFE.
Driver Output Voltage
The differential output voltage of the DS100DF410 can be configured from a nominal setting of 600 mV peak-topeak differential to a nominal setting of 1.3 V peak-to-peak differential, depending upon the application. The
driver output voltage as set is the typical peak-to-peak differential output voltage with no de-emphasis enabled.
12
Submit Documentation Feedback
Copyright © 2012–2013, Texas Instruments Incorporated
Product Folder Links: DS100DF410
DS100DF410
www.ti.com
SNLS399A – JANUARY 2012 – REVISED FEBRUARY 2013
Driver Output De-Emphasis
The output de-emphasis level of the DS100DF410 can be configured from a nominal setting of 0 dB to a nominal
setting of -12 dB depending upon the application. Larger absolute values of the de-emphasis setting provide
more pre-distortion of the output driver waveform, accentuating the high-frequency components of the output
driver waveform relative to the low-frequency components. Greater values of de-emphasis can compensate for
greater dispersion in the transmission media at the output of the DS100DF410. The output de-emphasis level as
set is the typical value to which the output signal will settle following the de-emphasis pulse interval in dB relative
to the output VOD.
Driver Output Rise/Fall Time
In some applications, a longer rise/fall time for the output signal is desired. This can reduce electromagnetic
interference (EMI) generated by fast switching waveforms. This is necessary in some applications for regulatory
compliance. In others, it can reduce the crosstalk in the system.
The DS100DF410 can be configured to operate with a nominal rise/fall time corresponding to the maximum slew
rate of the output drivers into the load capacitance. Alternatively, the DS100DF410 can be configured to operate
with a slightly greater rise/fall time if desired. For the typical specifications on rise/fall time, see Electrical
Characteristics
Ref_mode 0 Mode (reference clock not required)
The DS100DF410 can be used without using a reference clock and the input REFCLK_IN pin can be open.
When register 0x36, bits [5:4] are set to 2’b00, the device operates without using a reference clock at 10.3125
Gbps mode.
For 1GbE applications, it is required to bypass the CDR by setting the override bit 5 of register 0x09 to 1, and set
the data mux bits [7:5] to 3'b000 of register 0x1E.
Ref_mode 3 Mode (reference clock required)
When using ref_mode 3, the device uses an external 25 MHz clock. This mode of operation is set in register
0x36 bits [5:4] = 2'b11 and is the default setting. In ref_mode 3, the external reference clock is used to aid initial
phase lock, and to determine when its VCO is properly phase-locked. An external oscillator should be used to
generate a 2.5V, 25 MHz reference signal which is connected to the DS100DF410 on the reference clock input
pin (pin 19). The DS100DF410 does not include a crystal oscillator circuit, so a stand-alone external oscillator is
required.
The reference clock speeds up the initial phase lock acquisition. The DS100DF410 is set to phase lock to a
known data rate, or a constrained set of known data rates, and the digital circuitry in the DS100DF410 preconfigures the VCO frequency. This enables the DS100DF410 phase-lock to the incoming signal very quickly.
The reference clock is used to calibrate the VCO coarse tuning. However, the reference clock is not synchronous
to the data stream, and the quality of the reference clock does not affect the jitter on the output retimed data. The
retimed data clock for each channel is synchronous to the VCO internal to that channel of the DS100DF410.
The phase noise of the reference clock is not critical. Any commercially-available 25 MHz oscillator can provide
an acceptable reference clock. The reference clock can be daisy-chained from one retimer to another so that
only one reference oscillator is required in a system.
False Lock Detector Setting
The register 0x2F, bit 1 is set to 1 by default, which disables the false lock detector. This bit must be set to 0 to
enable the false lock detector function.
Reference Clock In
REFCLK_IN pin 19 is for reference clock input. A 25 MHz oscillator should be connected to pin 19. See Electrical
Characteristics for the requirements on the 25 MHz clock. The frequency of the reference clock should always be
25 MHz no matter what data rate or mode of operation is used.
Submit Documentation Feedback
Copyright © 2012–2013, Texas Instruments Incorporated
Product Folder Links: DS100DF410
13
DS100DF410
SNLS399A – JANUARY 2012 – REVISED FEBRUARY 2013
www.ti.com
Reference Clock Out
REFCLK_OUT pin 42 is the reference clock output pin. The DS100DF410 drives a buffered replica of the 25
MHz reference clock input on this output pin. If there are multiple DS100DF410 in the system, the REFCLK_OUT
pin can be directly connected to the REFCLK_IN pin of another DS100DF410 in a daisy chain connection. The
other option is to connect the external 25 MHz oscillator to a clock fanout buffer to distribute the 25 MHz clock to
each DS100DF410, which ensures there is a reference clock for the DS100DF410.
INT
The INT line is an open-drain, 3.3V tolerant, LVCMOS active-low output. The INT lines from multiple
DS100DF410s can be wired together and connected to an external controller.
The DS100DF410 generates an interrupt when it detects a loss of signal after previously detecting the presence
of a signal, or when it detects loss of lock after previously detecting phase lock. These interrupts are always
enabled. In addition, the Horizontal Eye Opening/Vertical Eye Opening (HEO/VEO) interrupt can be enabled
using SMBus control for each channel independently. This interrupt is disabled by default. The thresholds for
horizontal and vertical eye opening that will trigger the interrupt can be set using the SMBus control for each
channel.
If any interrupt occurs, registers in the DS100DF410 latch in information about the event that caused the
interrupt. This can then be read out by the controller over the SMBus.
LOCK_3, LOCK_2, LOCK_1, and LOCK_0
Each channel of the DS100DF410 has an independent lock indication pin. These lock indication pins, LOCK_3,
LOCK_2, LOCK_1, and LOCK_0, are pin 16, pin 21, pin 40, and pin 45 respectively. These pins are shared with
the SMBus address strap lines. After the address values have been latched in on power-up, these lines revert to
their lock indication function.
When the corresponding channel of the DS100DF410 is locked to the incoming data stream, the lock indication
pin goes high. This pin can be used to drive an LED on the board, giving a visual indication of the lock status, or
it can be connected to other circuitry which can interpret the lock status of the channel.
14
Submit Documentation Feedback
Copyright © 2012–2013, Texas Instruments Incorporated
Product Folder Links: DS100DF410
DS100DF410
www.ti.com
SNLS399A – JANUARY 2012 – REVISED FEBRUARY 2013
DEVICE CONFIGURATION MODES
The DS100DF410 can be configured using two different methods.
• SMBus Master Configuration Mode
• SMBus Slave Configuration Mode
The configuration mode is selected by the state of the EN_SMB pin (pin 20) when the DS100DF410 is poweredup. This pin should be either left floating or tied to the device VDD through an optional 1KΩ resistor. The effect of
each of these settings is shown in Table 1.
Table 1. SMBus Enable Settings
EN_SMB Pin Setting
Configuration Mode
Description
READ_EN Pin
Float
SMBus Master Mode
Device reads its configuration
from an external EEPROM on
power-up
Pull low to initiate reading
configuration data from external
EEPROM
High (1)
SMBus Slave Mode
Device is configured over the
SMBus by an external controller
Tie low to enable proper address
strapping on power-up
SMBus Master Mode and SMBus Slave Mode
In SMBus master mode the DS100DF410 reads its initial configuration from an external EEPROM upon powerup. A description of the operation of this mode appears in a separate application note.
Some of the pins of the DS100DF410 perform the same functions in SMBus master and SMBus slave mode.
Once the DS100DF410 has finished reading its initial configuration from the external EEPROM in SMBus master
mode it reverts to SMBus slave mode and can be further configured by an external controller over the SMBus.
Two device pins initiate reading the configuration from the external EEPROM and indicate when the configuration
read is complete.
• ALL_DONE
• READ_EN
These pins are meant to work together. When the DS100DF410 is powered up in SMBus master mode, it reads
its configuration from the external EEPROM. This is triggered when the READ_EN pin goes low. When the
DS100DF410 is finished reading its configuration from the external EEPROM, it drives its ALL_DONE pin low. In
this mode, as the name suggests, the DS100DF410 acts as an SMBus master during the time it is reading its
configuration from the external EEPROM. After the DS100DF410 has finished reading its configuration from the
EEPROM, it releases control of the SMBus and becomes a SMBus slave. In applications where there is more
than one DS100DF410 on the same SMBus, bus contention can result if more than one DS100DF410 tries to
take command of the SMBus as the SMBus master at the same time. The READ_EN and ALL_DONE pins
prevent this bus contention.
In a system where the DS100DF410s are meant to operate in SMBus master mode, the READ_EN pin of one
retimer should be wired to the ALL_DONE pin of the next. The system should be designed so that the READ_EN
pin of one (and only one) of the DS100DF410s in the system is driven low on power-up. This DS100DF410 will
take command of the SMBus on power-up and will read its initial configuration from the external EEPROM. When
it is finished reading its configuration, it will set its ALL_DONE pin low. This pin should be connected to the
READ_EN pin of another DS100DF410. When this DS100DF410 senses its READ_EN pin driven low, it will take
command of the SMBus and read its initial configuration from the external EEPROM, after which it will set its
ALL_DONE pin low. By connecting the ALL_DONE pin of each DS100DF410 to the READ_EN pin of the next
DS100DF410, each DS100DF410 can read its initial configuration from the EEPROM without causing bus
contention.
For SMBus slave mode, the READ_EN pin must be tied low. Do not leave it floating or tie it high.
A connection diagram showing several DS100DF410s along with an external EEPROM and an external SMBus
master is shown in Figure 3 below. The SMBus master must be prevented from trying to take control of the
SMBus until the DS100DF410s have finished reading their initial configurations from the EEPROM.
Submit Documentation Feedback
Copyright © 2012–2013, Texas Instruments Incorporated
Product Folder Links: DS100DF410
15
DS100DF410
SNLS399A – JANUARY 2012 – REVISED FEBRUARY 2013
www.ti.com
SDA
From External
SMBus Master
SDC
ALL_DONE_N
SDA
ADDR3
READ_EN_N
ADDR2
ADDR1
ADDR0
ADDR3
ADDR2
ADDR1
ADDR0
READ_EN_N
ADDR2
ADDR1
ADDR0
Set to unique
SMBus
address
Set to unique
SMBus
address
ALL_DONE_N
SDA
SDC
ALL_DONE_N
SDA
SDC
ALL_DONE_N
SDA
SDC
DS100DF410
DS100DF410
DS100DF410
ADDR3
READ_EN_N
ADDR1
ADDR2
Set to unique
SMBus
address
ADDR0
ADDR3
READ_EN_N
ADDR1
ADDR2
ADDR0
ADDR3
READ_EN_N
ADDR2
ADDR1
ADDR0
Set to unique
SMBus
address
DS100DF410
DS100DF410
One or both of these lines should
float for an EEPROM larger than
256 bytes
SDC
ALL_DONE_N
SDA
SDC
SDC
SDA
EEPROM
Set to unique
SMBus
address
Figure 3. Connection Diagram for Multiple DS100DF410s in SMBus Master Mode
In SMBus master mode after the DS100DF410 has finished reading its initial configuration from the external
EEPROM it reverts to SMBus slave mode. In either mode the SMBus data and clock lines, SDA and SDC, are
used. Also, in either mode, the SMBus address is latched in on the address strap lines on power-up. In SMBus
slave mode, if the READ_EN pin is not tied low, the DS100DF410 will not latch in the address on its address
strap lines. It will instead latch in an SMBus write address of 0x30 regardless of the state of the address strap
lines. This is a test feature. Obviously a system with multiple retimers cannot operate properly if all the retimers
are responding to the same SMBus address. Tie the READ_EN pin low when operating in SMBus slave mode to
avoid this condition.
The DS100DF410 reads its SMBus address upon power-up from the SMBus address lines.
Address Lines <ADDR_[3:0]>
In either SMBus master or SMBus slave mode the DS100DF410 must be assigned an SMBus address. A unique
address must be assigned to each device on the SMBus.
The SMBus address is latched into the DS100DF410 on power-up. The address is read in from the state of the
<ADDR_[3:0]> lines (pins 16, 21, 40, and 45 respectively) upon power-up. In either SMBus mode these address
lines are input pins on power-up.
16
Submit Documentation Feedback
Copyright © 2012–2013, Texas Instruments Incorporated
Product Folder Links: DS100DF410
DS100DF410
www.ti.com
SNLS399A – JANUARY 2012 – REVISED FEBRUARY 2013
The DS100DF410 can be configured with any of 16 SMBus addresses. The SMBus addressing scheme uses the
least-significant bit of the SMBus address as the Read/Write_N address bit. When an SMBus device is
addressed for writing, this bit is set to 0; for reading, to 1. Table 2 below shows the write address setting for the
DS100DF410 versus the values latched in on the address lines at power-up.
The address byte sent by the SMBus master over the SMBus is always 8 bits long. The least-significant bit
indicates whether the address is for a write operation, in which the master will output data to the SMBus to be
read by the slave, or a read operation, in which the slave will output data to the SMBus to be read by the master.
if the least-significant bit is a 0, the address is for a write operation. If it is a 1, the address is for a read
operation. Accordingly, SMBus addresses are sometimes referred to as seven-bit addresses. To produce the
write address for the SMBus, the seven-bit address is left-shifted by one bit. To produce the read address, it is
left shifted by one bit and the least-significant bit is set to 1. Table 2 shows the seven-bit addresses
corresponding to each set of address line values.
When the DS100DF410 is used in SMBus slave mode, the READ_EN pin must be tied low. If it is tied high or
floating, the DS100DF410 will not latch in its address from the address lines on power-up. When the READ_EN
pin is tied high in SMBus slave mode i.e. when the EN_SMB pin (pin 20) is tied high, the DS100DF410 will revert
to an SMBus write address of 0x30. This is a test feature. If there are multiple DS100DF410s on the same
SMBus, they will all revert to an SMBus write address of 0x30, which can cause SMBus collisions and failure to
access the DS100DF410s over the SMBus.
Table 2. DS100DF410 SMBus Write Address Assignment
ADDR_3
ADDR_2
ADDR_1
ADDR_0
SMBus Write
Address
Seven-bit SMBus
Address
0
0
0
0
0x30
0x18
0
0
0
1
0x32
0x19
0
0
1
0
0x34
0x1a
0
0
1
1
0x36
0x1b
0
1
0
0
0x38
0x1c
0
1
0
1
0x3a
0x1d
0
1
1
0
0x3c
0x1e
0
1
1
1
0x3e
0x1f
1
0
0
0
0x40
0x20
1
0
0
1
0x42
0x21
1
0
1
0
0x44
0x22
1
0
1
1
0x46
0x23
1
1
0
0
0x48
0x24
1
1
0
1
0x4a
0x25
1
1
1
0
0x4c
0x26
1
1
1
1
0x4e
0x27
Once the DS100DF410 has latched in its SMBus address, its registers can be read and written using the two
pins of the SMBus interface, Serial Data (SDA) and Serial Data Clock (SDC).
SDA and SDC
In both SMBus master and SMBus slave mode, the DS100DF410 is configured using the SMBus. The SMBus
consists of two lines, the SDA or Serial Data line (pin 18) and the SDC or Serial Data Clock line (pin 17). In the
DS100DF410 these pins are 3.3V tolerant. The SDA and SDC lines are both open-drain. They require a pull-up
resistor to a supply voltage, which may be either 2.5V or 3.3V. A pull-up resistor in the 2KΩ to 5KΩ range will
provide reliable SMBus operation.
The SMBus is a standard communications bus for configuring simple systems. For a specification of the SMBus
an description of its operation, see http://smbus.org/specs/.
Submit Documentation Feedback
Copyright © 2012–2013, Texas Instruments Incorporated
Product Folder Links: DS100DF410
17
DS100DF410
SNLS399A – JANUARY 2012 – REVISED FEBRUARY 2013
www.ti.com
REGISTER INFORMATION
There are two types of device registers in the DS100DF410. These are the control/shared registers and the
channel registers. The control/shared registers control or allow observation of settings which affect the operation
of all channels of the DS100DF410. They are also used to select which channel of the device is to be the target
channel for reads from and writes to the channel registers.
The channel registers are used to set all the configuration settings of the DS100DF410. They provide
independent control for each channel of the DS100DF410 for all the settable device characteristics.
Any registers not described in the tables that follow should be treated as reserved. The user should not try to
write new values to these registers. The user-accessible registers described in the tables that follow provide a
complete capability for customizing the operation of the DS100DF410 on a channel-by-channel basis.
Bit Fields in the Register Set
Many of the registers in the DS100DF410 are divided into bit fields. This allows a single register to serve multiple
purposes, which may be unrelated.
Often configuring the DS100DF410 requires writing a bit field that makes up only part of a register value while
leaving the remainder of the register value unchanged. The procedure for accomplishing this is to read in the
current value of the register to be written, modify only the desired bits in this value, and write the modified value
back to the register. Of course, if the entire register is to be changed, rather than just a bit field within the
register, it is not necessary to read in the current value of the register first.
In all the register configuration procedures described in the following sections, this procedure should be kept in
mind. In some cases, the entire register is to be modified. When only a part of the register is to be changed,
however, the procedure described above should be used.
Writing to and Reading from the Control/Shared Registers
Any write operation targeting register 0xff writes to the control/shared register 0xff. This is the only register in the
DS100DF410 with an address of 0xff.
Bit 2 of register 0xff is used to select either the control/shared register set or a channel register set. If bit 2 of
register 0xff is cleared (written with a 0), then all subsequent read and write operations over the SMBus are
directed to the control/shared register set. This situation persists until bit 2 of register 0xff is set (written with a 1).
There is a register with address 0x00 in the control/shared register set, and there is also a register with address
0x00 in each channel register set. If you read the value in register 0x00 when bit 2 of register 0xff is cleared to 0,
then the value returned by the DS100DF410 is the value in register 0x00 of the control/shared register set. If you
read the value in register 0x00 when bit 2 of register 0xff is set to 1, then the value returned by the DS100DF410
is the value in register 0x00 of the selected channel register set. The channel register set is selected by bits 1:0
of register 0xff.
If bit 3 of register 0xff is set to 1 and bit 2 of register 0xff is also set to 1, then any write operation to any register
address will write all the channel register sets in the DS100DF410 simultaneously. This situation will persist until
either bit 3 of register 0xff or bit 2 of register 0xff is cleared. Note that when you write to register 0xff,
independent of the current settings in register 0xff, the write operation ALWAYS targets the control/shared
register 0xff. This channel select register, register 0xff, is unique in this regard.
Table 3 below shows the control/shared register set. Any register addresses or register bits in the control/shared
register set not shown in this table should be considered reserved. In this table, the mode is either R for ReadOnly, R/W for Read-Write, or R/W/SC for Read-Write-Self-Clearing. If you try to write to a Read-Only register, the
DS100DF410 will ignore it.
18
Submit Documentation Feedback
Copyright © 2012–2013, Texas Instruments Incorporated
Product Folder Links: DS100DF410
DS100DF410
www.ti.com
SNLS399A – JANUARY 2012 – REVISED FEBRUARY 2013
Table 3. Control/Shared Registers
Address (Hex)
Bits
Default Value (Hex)
Mode
Description
0x00
7:4
0x0
R
SMBus Address Strap
Observation <3:0>
0x01
7:5
0x6
R
Device Revision
4:0
0x10
R
Device ID
6
0x0
R/W/SC
Self-Clearing Reset for
Control/Shared Registers
5
0x0
R/W
Reset for SMBus Master
Mode
4
0x0
R/W
Force EEPROM
Configuration
7
0x0
R/W
Disable Master Mode
EEPROM Configuration
4
(1)
R
EEPROM Read Complete
3
0x0
R
Set on Channel 0 Interrupt
2
0x0
R
Set on Channel 1 Interrupt
1
0x0
R
Set on Channel 2 Interrupt
0x04
0x05
0
0x0
R
Set on Channel 3 Interrupt
0x06
3:0
0X0
R/W
Diagnostic Test Control
Set to 0xa to read SMBus
strap values from register
0x00
0xff
3
0x0
R/W
Selects All Channels for
Register Write
See Table 4
2
0x0
R/W
Enables Register Write to
One or All Channels and
Register Read from One
Channel
See Table 4
1:0
0x0
R/W
Selects Target Channel
for Register Reads and
Writes
See Table 4
(1)
There is no default value. This bit always indicates whether the EEPROM read is complete or not.
SMBus Strap Observation
Register 0x00, bits 7:4 and register 0x06, bits 3:0
In order to communicate with the DS100DF410 over the SMBus, it is necessary for the SMBus controller to know
the address of the DS100DF410 . The address strap observation bits in control/shared register 0x00 are primarily
useful as a test of SMBus operation. There is no way to get the DS100DF410 to tell you what its SMBus address
is unless you already know what it is.
In order to use the address strap observation bits of control/shared register 0x00, it is necessary first to set the
diagnostic test control bits of control/shared register 0x06. This four-bit field should be written with a value of 0xa.
When this value is written to bits 3:0 of control/shared register 0x06, then the value of the SMBus address straps
can be read in register 0x00, bits 7:4. The value read will be the same as the value present on the
ADDR3:ADDR0 lines when the DS100DF410 was powered up. For example, if a value of 0x1 is read from
control/shared register 0x00, bits 7:4, then at power-up the ADDR0 line was set to 1 and the other address lines,
ADDR3:ADDR1, were all set to 0. The DS100DF410 is set to an SMBus Write address of 0x32.
Submit Documentation Feedback
Copyright © 2012–2013, Texas Instruments Incorporated
Product Folder Links: DS100DF410
19
DS100DF410
SNLS399A – JANUARY 2012 – REVISED FEBRUARY 2013
www.ti.com
Device Revision and Device ID
Register 0x01
Control/shared register 0x01 contains the device revision and device ID. The device revision shown in Table 3 is
the current revision for the DS100DF410. The device ID will be different for the different devices in the retimer
family. The value shown in "For the DS100DF410, Register 0x01, bits 4:0 = 0x10" is the correct value for the
DS100DF410. This register is useful because it can be interrogated by software to determine the device variant
and revision installed in a particular system. The software might then configure the device with appropriate
settings depending upon the device variant and revision.
Control/Shared Register Reset
Register 0x04, bit 6
Register 0x04, bit 6, clears all the control/shared registers back to their factory defaults. This bit is self-clearing,
so it is cleared after it is written and the control/shared registers are reset to their factory default values.
Interrupt Channel Flag Bits
Register 0x05, bits 3:0
The operation of these bits is described in the section on interrupt handling later in this data sheet.
SMBus Master Mode Control Bits
Register 0x04, bits 5 and 4 and register 0x05, bits 7 and 4
Register 0x04, bit 5, can be used to reset the SMBus master mode. This bit should not be set if the
DS100DF410 is in SMBus slave mode. This is an undefined condition.
When this bit is set, if the EN_SMB pin is floating (meaning that the DS100DF410 is in SMBus master mode),
then the DS100DF410 will read the contents of the external EEPROM when the READ_EN pin is pulled low. This
bit is not self-clearing, so it should be cleared after it is set.
When the DS100DF410 EN_SMB pin is floating (meaning that the DS100DF410 is in SMBus master mode), it
will read from its external EEPROM when its READ_EN pin goes low. After the EEPROM read operation is
complete, register 0x05, bit 4 will be set. Alternatively, the DS100DF410 will read from its external EEPROM
when triggered by register 0x04, bit 4, as described below.
When register 0x04, bit 4, is set, the DS100DF410 reads its configuration from an external EEPROM over the
SMBus immediately. When this bit is set, the DS100DF410 does not wait until the READ_EN pin is pulled low to
read from the EEPROM. This EEPROM read occurs whether the DS100DF410 is in SMBus master mode or not.
If the read from the EEPROM is not successful, for example because there is no EEPROM present, then the
DS100DF410 may hang up and a power-up reset may be necessary to return it to proper operation. You should
only set this bit if you know that the EEPROM is present and properly configured.
If the EEPROM read has already completed, then setting register 0x04, bit 4, will not have any effect. To cause
the DS100DF410 to read from the EEPROM again it is necessary to set bit 5 of register 0x04, resetting the
SMBus master mode. If the DS100DF410 is not in SMBus master mode, do not set this bit. After setting this bit,
it should be cleared before further SMBus operations.
After SMBus master mode has been reset, the EEPROM read may be initiated either by pulling the READ_EN
pin low or by then setting register 0x04, bit 4.
Register 0x05, bit 7, disables SMBus master mode. This prevents the DS100DF410 from trying to take command
of the SMBus to read from the external EEPROM. Obviously this bit will have no effect if the EEPROM read has
already taken place. It also has no effect if an EEPROM read is currently in progress. The only situations in
which disabling EEPROM master mode read is valid are (1) when the DS100DF410 is in SMBus master mode,
but the READ_EN pin has not yet gone low, and (2) when register 0x04, bit 5, has been used to reset SMBus
master mode but the EEPROM read operation has not yet occurred.
Do not set this bit and bit 4 of register 0x04 simultaneously. This is an undefined condition and can cause the
DS100DF410 to hang up.
20
Submit Documentation Feedback
Copyright © 2012–2013, Texas Instruments Incorporated
Product Folder Links: DS100DF410
DS100DF410
www.ti.com
SNLS399A – JANUARY 2012 – REVISED FEBRUARY 2013
Channel Select Register
Register 0xff, bits 3:0
Register 0xff, as described above, selects the channel or channels for channel register reads and writes. It is
worth describing the operation of this register again for clarity. If bit 3 of register 0xff is set, then any channel
register write applies to all channels. Channel register read operations always target only the channel specified in
bits 1:0 of register 0xff regardless of the state of bit 3 of register 0xff. Read and write operations target the
channel register sets only when bit 2 of register 0xff is set.
Bit 2 of register 0xff is the universal channel register enable. This bit must be set in order for any channel register
reads and writes to occur. If this bit is set, then read operations from or write operations to register 0x00, for
example, target channel register 0x00 for the selected channel rather than the control/shared register 0x00. In
order to access the control/shared registers again, bit 2 of register 0xff should be cleared. Then the
control/shared registers can again be accessed using the SMBus. Write operations to register 0xff always target
the register with address 0xff in the control/shared register set. There is no other register, and specifically, no
channel register, with address 0xff.
The contents of the channel select register, register 0xff, cannot be read back over the SMBus. Read operations
on this register will always yield an invalid result. All eight bits of this register should always be set to the desired
values whenever this register is written. Always write 0x0 to the four MSBs of register 0xff. The register set target
selected by each valid value written to the channel select register is shown in Table 4
Table 4. Channel Select Register Values Mapped to Register Set Target
Register 0xff Value (hex) Shared/Channel
Register Selection
Broadcast Channel
Register Selection
Targeted Channel
Selection
Comments
0x00
Shared
N/A
N/A
All reads and writes target
shared register set
0x04
Channel
No
0
All reads and writes target
channel 0 register set
0x05
Channel
No
1
All reads and writes target
channel 1 register set
0x06
Channel
No
2
All reads and writes target
channel 2 register set
0x07
Channel
No
3
All reads and writes target
channel 3 register set
0x0c
Channel
Yes
0
All writes target all
channel register sets, all
reads target channel 0
register set
0x0d
Channel
Yes
1
All writes target all
channel register sets, all
reads target channel 1
register set
0x0e
Channel
Yes
2
All writes target all
channel register sets, all
reads target channel 2
register set
0x0f
Channel
Yes
3
All writes target all
channel register sets, all
reads target channel 3
register set
Reading to and Writing from the Channel Registers
Each of the four channels has a complete set of channel registers associated with it. The channel registers or the
control/shared registers are selected by channel select register 0xff. The settings in this register control the target
for subsequent register reads and writes until the contents of register 0xff are explicitly changed by a register
write to register 0xff. As noted, there is only one register with an address of 0xff, the channel select register.
Submit Documentation Feedback
Copyright © 2012–2013, Texas Instruments Incorporated
Product Folder Links: DS100DF410
21
DS100DF410
SNLS399A – JANUARY 2012 – REVISED FEBRUARY 2013
www.ti.com
Table 5. Channel Registers
Address (Hex)
Bits
Default Value (Hex)
Mode
Field Name
Description
0x00
2
0x0
R/W/SC
rst_regs
Reset Channel
Registers to Defaults
(Self-clearing)
0x01
4
0x0
R
cdr_lock_loss_int
CDR Lock Loss
Interrupt
0
0x0
R
signal_detect_loss_int Signal Detect Loss
Interrupt
7:6
0x0
R/W
eq_BST0[1:0]
CTLE Boost Stage 0
<1:0>
5:4
0x0
R/W
eq_BST1[1:0]
CTLE Boost Stage 1
<1:0>
3:2
0x0
R/W
eq_BST2[1:0]
CTLE Boost Stage 2
<1:0>
1:0
0x0
R/W
eq_BST3[1:0]
CTLE Boost Stage 3
<1:0>
0x08
4:0
0x00
R/W
cdr_cap_dac_start[4:
0]
Override Starting
VCO Cap DAC
Setting 0 <4:0>
0x09
7
0x0
R/W
reg_divsel_vco_cap_
ov
Enable Override VCO
Cap DAC (Registers
0x08 and 0x0b)
5
0x0
R/W
reg_bypass_pfd_ov
Enable Override
Output Mux (Register
0x1e)
2
0x0
R/W
reg_divsel_ov
Enable Override
Divider Select
(Register 0x18)
3
0x0
R/W
reg_cdr_reset_ov
Enable CDR Reset
Override (Register
0x0a)
2
0x0
R/W
reg_cdr_reset_sm
CDR Reset Override
Bit
0x0b
4:0
0x0f
R/W
cdr_cap_dac_start1[4 Override VCO Cap
:0]
DAC Setting 1 <4:0>
0x0d
5
0x0
R/W
PRBS_PATT_SHIFT_ PRBS Generator
EN
Clock Enable
0x11
7:6
0x0
R/W
eom_sel_vrange[1:0]
Eye Opening Monitor
Voltage Range <1:0>
5
0x1
R/W
eom_PD
Eye Opening Monitor
Power Down
3
0x0
R/W
dfe_tap2_pol
DFE Tap 2 Polarity
2
0x0
R/W
dfe_tap3_pol
DFE Tap 3 Polarity
1
0x0
R/W
dfe_tap4_pol
DFE Tap 4 Polarity
0
0x0
R/W
dfe_tap5_pol
DFE Tap 5 Polarity
7
0x1
R/W
dfe_tap1_pol
DFE Tap 1 Polarity
4:0
0x00
R/W
dfe_wt1[4:0]
DFE Tap 1 Weight
<4:0>
0x13
2
0x0
RW
eq_BST3[2]
CTLE Boost Stage 3,
Bit 2 (Limiting Bit)
0x14
7
0x0
R/W
eq_sd_preset
Force Signal Detect
On
6
0x0
R/W
eq_sd_reset
Force Signal Detect
Off
7
0x0
R/W
dfe_manual_tap_en
Enables manual DFE
tap settings
6
0x0
R/W
drv_dem_range
Driver De-emphasis
Range
0x03
0x0a
0x12
0x15
22
Submit Documentation Feedback
Copyright © 2012–2013, Texas Instruments Incorporated
Product Folder Links: DS100DF410
DS100DF410
www.ti.com
SNLS399A – JANUARY 2012 – REVISED FEBRUARY 2013
Table 5. Channel Registers (continued)
Address (Hex)
Bits
Default Value (Hex)
Mode
Field Name
Description
2:0
0x0
R/W
drv_dem[2:0]
Driver De-emphasis
Setting<2:0>
6:4
0x4
R/W
pdiq_sel_div[2:0]
VCO Divider Ratio
<2:0> (Enable from
Register 0x09, Bit 2)
2
0x0
R/W
drv_sel_slow
Enable Slow Rise/Fall
Time on Output
Driver
7:5
0x7
R/W
pfd_sel_data_mux[2:0 OutputMux <2:0>
]
(Enable from Register
0x09, Bit 5)
4
0x0
R/W
prbs_en
Enable PRBS
Generator
3
0x1
R/W
dfe_PD
DFE is powered down
by default. Must set
bit to 0 to power up
the DFE.
0x1f
7
0x0
R/W
drv_sel_inv
Select Output Polarity
Inverted
0x20
7:4
0x0
R/W
dfe_wt5[3:0]
DFE Tap 5 Weight
<3:0>
3:0
0x0
R/W
dfe_wt4[3:0]
DFE Tap 4 Weight
<3:0>
7:4
0x0
R/W
dfe_wt3[3:0]
DFE Tap 3 Weight
<3:0>
3:0
0x0
R/W
dfe_wt2[3:0]
DFE Tap 2 Weight
<3:0>
0x23
6
0x1
R/W
dfe_ov
DFE Override
0x24
7
0x0
R/W
fast_eom
Enable Fast Eye
Opening Monitor
Mode
2
0x0
R/W/SC
dfe_adapt
Start DFE Adaptation
(Self-Clearing)
0
0x0
R/W/SC
eom_start
Start Eye Opening
Monitor Counter
(Self-Clearing)
0x25
7:0
0x0
R
eom_count[15:8]
Eye Opening Monitor
Count <15:8>
0x26
7:0
0x0
R
eom_count[7:0]
Eye Opening Monitor
Count <7:0>
0x27
7:0
0x0
R
heo[7:0]
HEO Value <7:0>
0x28
7:0
0x0
R
veo[7:0]
VEO Value <7:0>
0x29
6:5
0x0
R
eom_vrange_setting[
1:0]
Eye Opening Monitor
Voltage Range
Setting <1:0>
0x2a
7:0
0x30
R/W
eom_timer_thr[7:0]
Eye Opening Monitor
Timer Threshold
<7:0>
0x2c
5:4
0x3
R/W
dfe_sm_fom[1:0]
DFE Adaptation
Figure of Merit Type
<1:0>
3:0
0x2
R/W
dfe_adapt_counter[3:
0]
Counter Used in
Adaptation for LookBeyond when Figure
of Merit Decreases
2:0
0x0
R/W
drv_sel_vod[2:0]
Driver VOD <2:0>
0x18
0x1e
0x21
0x2d
Submit Documentation Feedback
Copyright © 2012–2013, Texas Instruments Incorporated
Product Folder Links: DS100DF410
23
DS100DF410
SNLS399A – JANUARY 2012 – REVISED FEBRUARY 2013
www.ti.com
Table 5. Channel Registers (continued)
Address (Hex)
Bits
Default Value (Hex)
Mode
Field Name
Description
0x2f
7:6
0x0
R/W
RATE[1:0]
Rate <1:0>
5:4
0x0
R/W
SUBRATE[1:0]
Subrate <1:0>
3
0x0
R/W
index_ov
CTLE Adaptation
Index Override
(Register 0x13)
2
0x1
R/W
en_ppm_check
Enable Frequency
Counter for Lock
Detect
1
0x1
R/W
en_fld_check
False Lock Detector
for lock detect is
disabled by default.
Must set bit to 0 to
enable the FLD.
0
0x0
R/W
ctle_adapt
Start CTLE
Adaptation
4
0x0
R
heo_veo_interrupt
Goes High if Interrupt
from CDR Goes High
3
0x0
R/W
prbs_en_dig_clk
PRBS Generator
Enable
1:0
0x0
R/W
prbs_pattern_sel[1:0]
PRBS Generator
Pattern Select <1:0>
6:5
0x1
R/W
adapt_mode[1:0]
Adaptation Mode
<1:0>
4:3
0x0
R/W
eq_sm_fom[1:0]
CTLE Adaptation
Figure of Merit Type
<1:0>
7:4
0x1
R/W
heo_int_thresh[3:0]
HEO Interrupt
Threshold <3:0>
3:0
0x1
R/W
veo_int_thresh[3:0]
VEO Interrupt
Threshold <3:0>
7:4
0x8
R/W
heo_thresh[3:0]
HEO Threshold for
CTLE Adaptation
Handoff to DFE
Adaptation <3:0>
3:0
0x8
R/W
veo_thresh[3:0]
VEO Threshold for
CTLE Adaptation
Handoff to DFE
Adaptation <3:0>
0x34
3:0
0xf
R/W
dfe_max_tap_2_5[3:0 Maximum DFE Tap
]
Absolute Value for
Taps 2–5 <3:0>
0x35
4:0
0x1f
R/W
dfe_max_tap_1[4:0]
Maximum DFE Tap
Absolute Value for
Tap 1 <4:0>
0x36
6
0x0
R/W
heo_veo_int_enable
Enable HEO/VEO
Interrupt
5:4
0x3
R/W
ref_mode[1:0]
Reference Clock
Mode <1:0>
2
0x0
R/W
mr_cdr_cap_dac_rng
_ov
Enable Override for
VCO Cap DAC
Range
1:0
0x1
R/W
mr_cdr_cap_dac_rng[ Cap DAC Range
1:0]
<1:0>
4:0
0x0
R/W
start_index[4:0]
0x30
0x31
0x32
0x33
0x39
24
Submit Documentation Feedback
Start Index for CTLE
Adaptation <4:0>
(Enable from Register
0x2f, Bit 3)
Copyright © 2012–2013, Texas Instruments Incorporated
Product Folder Links: DS100DF410
DS100DF410
www.ti.com
SNLS399A – JANUARY 2012 – REVISED FEBRUARY 2013
Table 5. Channel Registers (continued)
Address (Hex)
Bits
Default Value (Hex)
Mode
Field Name
Description
0x3a
7:6
0x2
R/W
fixed_eq_BST0[1:0]
Fixed CTLE Stage 0
Boost Setting for
Lower Data Rates
<1:0>
5:4
0x2
R/W
fixed_eq_BST1[1:0]
Fixed CTLE Stage 1
Boost Setting for
Lower Data Rates
<1:0>
3:2
0x1
R/W
fixed_eq_BST2[1:0]
Fixed CTLE Stage 2
Boost Setting for
Lower Data Rates
<1:0>
1:0
0x1
R/W
fixed_eq_BST3[1:0]
Fixed CTLE Stage 3
Boost Setting for
Lower Data Rates
<1:0>
0x3e
7
0x1
R/W
HEO_VEO_LOCKMO Enable HEO/VEO
N_EN
Lock Monitoring
0x40 – 0x5f
CTLE Settings for Adaptation – see Table 12
0x6a
7:4
0x4
R/W
veo_lck_thrsh[3:0]
Vertical Eye Opening
Lock Threshold <3:0>
3:0
0x4
R/W
heo_lck_thrsh[3:0]
Horizontal Eye
Opening Lock
Threshold <3:0>
0x6b
7:0
0x0
R/W
fom_a[7:0]
Adaptation Figure of
Merit Term a<7:0>
0x6c
7:0
0x0
R/W
fom_b[7:0]
Adaptation Figure of
Merit Term b<7:0>
0x6d
7:0
0x0
R/W
fom_c[7:0]
Adaptation Figure of
Merit Term c<7:0>
0x6e
7
0x0
R/W
en_new_fom_ctle
Enable Alternate
Figure of Merit for
CTLE Adaptation
6
0x0
R/W
en_new_fom_dfe
Enable Alternate
Figure of Merit for
DFE Adaptation
0x70
2:0
0x3
R/W
eq_lb_cnt[2:0]
CTLE Adaptation
Look-Beyond Count
<2:0>
0x71
5
0x0
R
dfe_pol_1_obs
DFE Tap 1 Polarity
(Read Only)
4:0
0x00
R
dfe_wt1_obs[4:0]
DFE Tap 1 Weight
(Read Only) <4:0>
4
0x0
R
dfe_pol_2_obs
DFE Tap 2 Polarity
(Read Only)
3:0
0x0
R
dfe_wt2_obs[3:0]
DFE Tap 2 Weight
(Read Only) <3:0>
4
0x0
R
dfe_pol_3_obs
DFE Tap 3 Polarity
(Read Only)
3:0
0x0
R
dfe_wt3_obs[3:0]
DFE Tap 3 Weight
(Read Only) <3:0>
4
0x0
R
dfe_pol_4_obs
DFE Tap 4 Polarity
(Read Only)
3:0
0x0
R
dfe_wt4_obs[3:0]
DFT Tap 4 Weight
(Read Only) <3:0>
0x72
0x73
0x74
Submit Documentation Feedback
Copyright © 2012–2013, Texas Instruments Incorporated
Product Folder Links: DS100DF410
25
DS100DF410
SNLS399A – JANUARY 2012 – REVISED FEBRUARY 2013
www.ti.com
Table 5. Channel Registers (continued)
Address (Hex)
Bits
Default Value (Hex)
Mode
Field Name
Description
0x75
4
0x0
R
dfe_pol_5_obs
DFE Tap 5 Polarity
(Read Only)
3:0
0x0
R
dfe_wt5_obs[3:0]
DFE Tap 5 Weight
(Read Only) <3:0>
Resetting Individual Channels of the Retimer
Register 0x00, bit 2, and register 0x0a, bits 3:2
Bit 2 of channel register 0x00 are used to reset all the registers for the corresponding channel to their factory
default settings. This bit is self-clearing. Writing this bit will clear any register changes you have made in the
DS100DF410 since it was powered-up.
To reset just the CDR state machine without resetting the register values, which will re-initiate the lock and
adaptation sequence for a particular channel, use channel register 0x0a. Set bit 3 of this register to enable the
reset override, then set bit 2 to force the CDR state machine into reset. These bits can be set in the same
operation. When bit 2 is subsequently cleared, the CDR state machine will resume normal operation. If a signal
is present at the input to the selected channel, the DS100DF410 will attempt to lock to it and will adapt its CTLE
and its DFE according to the currently configured adapt mode for the selected channel. The adapt mode is
configured by channel register 0x31, bits 6:5.
Interrupt Status
Control/Shared Register 0x05, bits 3:0, Register 0x01, bits 4 and 0, Register 0x30, bit 4, Register 0x32, and
Register 0x36, bit 6
Each channel of the DS100DF410 will generate an interrupt under several different conditions. The DS100DF410
will always generate an interrupt when it loses CDR lock or when a signal is no longer detected at its input. If the
HEO/VEO interrupt is enabled by setting bit 6 of register 0x36, then the retimer will generate an interrupt when
the horizontal or vertical eye opening falls below the preset values even if the retimer remains locked. When one
of these interrupt conditions occurs, the retimer alerts the system controller via hardware and provides additional
details via register reads over the SMBus.
First, the open-drain interrupt line INT is pulled low. This indicates that one or more of the channels of the retimer
has generated an interrupt. The interrupt lines from multiple retimers can be wire-ANDed together so that if any
retimer generates an interrupt the system controller can be notified using a single interrupt input.
if the interrupt has occurred because the horizontal or vertical eye opening has dropped below the pre-set
threshold, which is set in channel register 0x32, then bit 4 of register 0x30 will go high. This indicates that the
source of the interrupt was the HEO or VEO.
If the interrupt has occurred because the CDR has fallen out of lock, or because the signal is no longer detected
at the input, then bit 4 and/or bit 0 of register 0x01 will go high, indicating the cause of the interrupt.
In either case, the control/shared register set will indicate which channel caused the interrupt. This is read from
bits 3:0 of control/shared register 0x05.
When an interrupt is detected by the controller on the interrupt input, the controller should take the following
steps to determine the cause of the interrupt and clear it.
1. The controller detects the interrupt by detecting that the INT line has been pulled low by one of the retimers
to which it is connected.
2. The controller reads control/shared register 0x05 from all the DS100DF410s connected to the INT line. For at
least one of these devices, at least one of the bits 3:0 will be set in this register.
3. For each device with a bit set in bits 3:0 of control/shared register 0x05, the controller determines which
channel or channels produced an interrupt. Refer to Table 3 for a mapping of the bits in this bit field to the
channel producing the interrupt.
4. When the controller detects that one of the retimers has a 1 in one of the four LSBs of this register, the
controller selects the channel register set for that channel of that retimer by writing to the channel select
register, 0xff, as previously described.
5. For each channel that generated an interrupt, the controller reads channel register 0x01. If bit 4 of this
26
Submit Documentation Feedback
Copyright © 2012–2013, Texas Instruments Incorporated
Product Folder Links: DS100DF410
DS100DF410
www.ti.com
6.
7.
8.
9.
SNLS399A – JANUARY 2012 – REVISED FEBRUARY 2013
register is set, then the interrupt was caused by a loss of CDR lock. If bit 0 is set, then the interrupt was
caused by a loss of signal. it is possible that both bits 0 and 4 could be set. Reading this register will clear
these bits.
Optionally, for each channel that generated an interrupt, the controller reads channel register 0x30. If bit 4 of
this register is set, then the interrupt was caused by HEO and/or VEO falling out of the configured range.
This interrupt will only occur if bit 6 of channel register 0x36 is set, enabling the HEO/VEO interrupt. Reading
register 0x30 will clear this interrupt bit.
Once the controller has determined what condition caused the interrupt, the controller can then take the
appropriate action. For example, the controller might reset the CDR to cause the retimer to re-adapt to the
incoming signal. If there is no longer an incoming signal (indicated by a loss of signal interrupt, bit 0 of
channel register 0x01), then the controller might alert an operator or change the channel configuration. This
is system dependent.
Reading the interrupt status registers will clear the interrupt. if this does not cause the interrupt input to go
high, then another device on the same input has generated an interrupt. The controller can address the next
device using the procedure above.
Once all the interrupt registers for all channels for all DS100DF410s that generated interrupts have been
read, clearing all the interrupt indications, the INT line should go high again. This indicates that all the
existing interrupt conditions have been serviced.
The channel registers referred to above, registers 0x01, 0x30, 0x32, and 0x36, are described in the channel
registers table, Table 5.
Overriding the CTLE Boost Setting
Register 0x03, Register 0x13, bit 2, and Register 0x3a
To override the CTLE boost settings, register 0x03 is used. This register contains the currently-applied CTLE
boost settings. The boost values can be overridden by using the two-bit fields in this register as shown in the
table.
The final stage of the CTLE has an additional control bit which sets it to a limiting mode. For some channels, this
additional setting improves the bit error rate performance. This bit is bit 2 of register 0x13.
If the DS100DF410 loses lock because of a change in the CTLE settings, the DS100DF410 will initiate its lock
and adaptation sequence again. Thus, if you write new CTLE boost values to register 0x03 and 0x13 which
cause the DS100DF410 to drop out of lock, the DS100DF410 may, in the process of reacquiring the CDR lock,
reset the CTLE settings to different values than those you set in register 0x03 and 0x13. If this behavior is not
understood, it can appear that the DS100DF410 did not accept the values you wrote to the CTLE boost registers.
What's really happening, however, is that the lock and adaptation sequence is overriding the CTLE values you
wrote to the CTLE boost registers. This will not happen unless the DS100DF410 drops out of lock.
if the adapt mode is set to 0 (bits 6:5 of channel register 0x31), then the CTLE boost values will not be
overridden, but the DS100DF410 may still lose lock. If this happens, the DS100DF410 will attempt to reacquire
lock. if the reference mode is set correctly, and if the rate/subrate code is set to permit it, the DS100DF410 will
begin searching for CDR lock at the highest allowable VCO divider ratio – that is, at the lowest configured bit
rate. At this lowest bit rate, the CTLE boost settings used will come not from the values in register 0x03, and
0x13, but rather from register 0x3a, the fixed CTLE boost setting for lower data rates. This setting will be written
into boost setting register 0x03 during the lock search process. This value may be different from the value you
set in register 0x03, so, again, it may appear that the DS100DF410 has not accepted the CTLE boost settings
you set in registers 0x03 and 0x13. The interactions of the lock and adaptation sequences with the manually-set
CTLE boost settings can be difficult to understand.
To manually override the CTLE boost under all conditions, perform the following steps.
1. Set the DS100DF410 channel adapt mode to 0 by writing 0x0 to bits 6:5 of channel register 0x31.
2. Set the desired CTLE boost setting in register 0x3a. If the DS100DF410 loses lock and attempts to lock to a
lower data rate, it will use this CTLE boost setting.
3. Set the desired CTLE boost setting in register 0x03. This may cause the DS100DF410 to lose lock.
4. If desired, set the CTLE stage 3 limiting bit, bit 2 of register 0x13.
If the DS100DF410 loses lock when the CTLE boost settings are set according to the sequence above, the
DS100DF410 will try to reacquire lock, but it will not change the CTLE boost settings in order to do so.
Submit Documentation Feedback
Copyright © 2012–2013, Texas Instruments Incorporated
Product Folder Links: DS100DF410
27
DS100DF410
SNLS399A – JANUARY 2012 – REVISED FEBRUARY 2013
www.ti.com
Overriding the VCO CAP DAC Values
Register 0x08, bits 4:0, Register 0x09, bit 7, Register 0x0b, bits 4:0, Register 0x36, bits 5:4, and Register 0x2f,
bits 7:6 and 5:4
Registers 0x08 and 0x0b contain CAP DAC override values. Normally, when bits 5:4 of register 0x36 are set to
2'b11, then the DS1010DF410 performs an initial search to determine the correct CAP DAC setting (coarse VCO
tuning) for the selected rate and subrate. The rate and subrate settings (bits 7:6 and 5:4 of register 0x2f)
determine the frequency range to be searched, with the 25 MHz reference clock used as the frequency reference
for the frequency search.
The CAP DAC value can be overridden by writing new values to bits 4:0 of register 0x08 (for CAP DAC setting 1)
and bits 4:0 of 0x0b (for CAP DAC setting 2). The override bit, bit 7 of register 0x09 must be set for the override
CAP DAC values to take effect. Since the valid rate and subrate setting for 10 GbE and 1 GbE applies to multiple
data rates, there are two CAP DAC values for this rate. The first is in register 0x08, bits 4:0, and the second is in
register 0x0b, bits 4:0. The DS100DF410 will use the CAP DAC value in register 0x08 for the larger divide ratio
(8) associated with the selected rate and subrate to try and acquire lock. If it fails to acquire lock, it will use the
CAP DAC value in register 0x0b with the smaller divide ratio (higher VCO frequency) associated with the
selected rate and subrate (1). It will continue to try to acquire lock in this way until it either succeeds or the
override bit (bit 7 of register 0x09) is cleared.
Overriding the Output Multiplexer
Register 0x09, bit 5, Register 0x14, bits 7:6, and Register 0x1e, bits 7:5
By default, the DS100DF410 output for each channel will be as shown in Table 6.
Table 6. Default Output Status Description
Input Signal Status
Channel Status
Output Status
Not Present
No Signal Detected
Muted
Present
Not Locked
Muted
Present
Locked
Retimed Data
This default behavior can be modified by register writes.
Register 0x1e, bits 7:5, contain the output multiplexer override value. The values of this three-bit field and the
corresponding meanings of each are shown in
Table 7. Output Multiplexer Override Settings
Bit Field Value
Output Multiplexer Setting
Comments
0x7
Mute
Default when no signal is present or when
the retimer is unlocked
0x6
N/A
Invalid Setting
0x5
10 MHz Clock
Internal 10 MHz clock
Clock frequency may not be precise
0x4
PRBS Generator
PRBS Generator must be enabled to output
PRBS sequence
0x3
VCO Q-Clock
Register 0x09, bit 4, and register 0x1e, bit 0,
must be set to enable the VCO Q-Clock
0x2
VCO I-Clock
0x1
Retimed Data
0x0
Raw Data
Default when the retimer is locked
If the output multiplexer is not overridden, that is, if bit 5 of register 0x09 is not set, then the value in register
0x1e, bits 7:5, controls the output produced when the retimer has a signal at its input, but is not locked to it. The
default value for this bit field, 0x7, causes the retimer output to mute when the retimer is not locked to an input
signal. Writing a value of 0x0 to this bit field, for example, will cause the retimer to output raw data when it is not
locked to its input signal.
Setting the override bit, bit 5 of register 0x09, will cause the retimer to output the value selected by the bit field in
register 0x1e, bits 7:5, even when the retimer is locked.
28
Submit Documentation Feedback
Copyright © 2012–2013, Texas Instruments Incorporated
Product Folder Links: DS100DF410
DS100DF410
www.ti.com
SNLS399A – JANUARY 2012 – REVISED FEBRUARY 2013
When no signal is present at the input to the selected channel of the DS100DF410 the signal detect circuitry will
power down the channel. This includes the output driver which is therefore muted when no signal is present at
the input. If you want to get an output when no signal is present at the input, for example to enable a freerunning PRBS sequence, the first step is to override the signal detect. In order to force the signal detect on, set
bit 7 and clear bit 6 of channel register 0x14. Even if there is no signal at the input to the channel, the channel
will be enabled. If the channel was disabled before, the current drain from the supply will increase by 100–150
mA depending upon the other channel settings in the device. This increased current drain indicates that the
channel is now enabled.
The second step is to override the output multiplexer setting. This is accomplished by setting bit 5 of register
0x09, the output multiplexer override. Once this bit is set, the value of register 0x1e, bits 7:5 will control the
output of the channel. Note that if either retimed or raw data is selected, the output will just be noise. The device
output may saturate to a static 1 or 0.
If there is no signal, the VCO clock will be free-running. Its frequency will depend upon the divider and CAP DAC
settings and it will vary from part to part and over temperature.
If the PRBS generator is enabled, the PRBS generator output can be selected. This can either be at a data rate
determined by the free-running VCO or at a data rate determined by the input signal, if one is present. If a signal
is present at the input and the DS100DF410 can lock to it, the output of the PRBS generator will be synchronous
with the input signal, but the bit stream output will be determined by the PRBS generator selection.
The 10 MHz clock is always available at the output when the output multiplexer is overridden. The 10 MHz clock
is a free-running oscillator in the DS100DF410 and is not synchronous to the input or to anything else in the
system. The clock frequency will be approximately 10 MHz, but this will vary from part to part.
If there is a signal present at the input, it is not necessary to override the signal detect. Clearing bits 7 and 6 of
register 0x14 will return control of the signal detect to the DS100DF410. Normally, when the retimer is locked to
a signal at its input, it will output retimed data. However, if desired, the output multiplexer can be overridden in
this condition to output raw data. It can also be set to output any of the other signals shown in Table 7. If there is
an input signal, and if the DS100DF410 is locked to it, the VCO I-Clock, the VCO Q-Clock, and the output of the
PRBS generator, if it is enabled, will be synchronous to the input signal.
When a signal is present at the input, it might be desired to output the raw data in order to see the effects of the
CTLE and the DFE without the CDR. It might also be desired to enable the PRBS generator and output this
signal, replacing the data content of the input signal with the internally-generated PRBS sequence.
Overriding the VCO Divider Selection
Register 0x09, bit 2, and Register 0x18, bits 6:4
In normal operation, the DS100DF410 sets its VCO divider to the correct divide ratio, either 1, 2, 4, 8, or 16,
depending upon the bit rate of the signal at the channel input. It is possible to override the divider selection. This
might be desired if the VCO is set to free-run, for example, to output a signal at a sub-harmonic of the actual
VCO frequency.
In order to override the VCO divider settings, first set bit 2 of register 0x09. This is the VCO divider override
enable. Once this bit is set, the VCO divider setting is controlled by the value in register 0x18, bits 6:4. The valid
values for this three-bit field are 0x0 to 0x4. The mapping of the bit field values to the divider ratio is shown in
Table 8.
Table 8. Divider Ratio Mapping to Register 0x18, Bits 6:4
Bit Field Value
Divider Ratio
0
1
1
2
2
4
3
8
4
16
Submit Documentation Feedback
Copyright © 2012–2013, Texas Instruments Incorporated
Product Folder Links: DS100DF410
29
DS100DF410
SNLS399A – JANUARY 2012 – REVISED FEBRUARY 2013
www.ti.com
In normal operation, the DS100DF410 will determine the required VCO divider ratio automatically. The most
common application for overriding the divider ratio is when the VCO is set to free-run. Normally the divider ratio
should not be overridden except in this case.
Using the PRBS Generator
Register 0x0d, bit 5, Register 0x1e, bit 4, and Register 0x30, bit 3 and bits 1:0
The DS100DF410 includes an internal PRBS generator which can generate standard PRBS-9 and PRBS-31 bit
sequences. The PRBS generator can produce a PRBS sequence that is synchronous to the incoming data
signal, or it can generate a PRBS sequence using the internal free-running VCO as a clock. Both modes of
operation are described in the paragraphs that follow.
To produce a PRBS sequence that is synchronized to the incoming data signal, the DS100DF410 must be
locked to the incoming signal. When this is true, the signal detect is set and the channel is active. In addition, the
VCO is locked to the incoming signal The VCO will remain locked to the incoming signal regardless of the state
of the output multiplexer.
To activate the PRBS generator, first set bit 4 of register 0x1e. This bit enables the PRBS generator digital
circuitry. Then reset the PRBS clock by clearing bit 3 of register 0x30. Select either PRBS-9 or PRBS-31 by
setting bits 1:0 of register 0x30. Set this bit field to 0x0 for PRBS-9 and to 0x2 for PRBS-31. Then load the PRBS
clock by setting bit 3 of register 0x30. Finally, enable the PRBS clock by setting bit 5 of register 0x0d. This
sequence of register writes will enable the internal PRBS generator.
As described above, to select the PRBS generator as the output for the selected channel, set bit 5 of register
0x09, the output multiplexer override. Then write 0x4 to bits 7:5 of register 0x1e. This selects the PRBS
generator for output.
For the case described above, the output PRBS sequence will be synchronous to the incoming data. There are
two other cases of interest. The first is when there is an input signal but the PRBS sequence should not be
synchronous to it. In other words, in this case it is desired that the VCO should free-run. The second case is
when there is no input signal, but the PRBS sequence should still be output. Again, in this case, the VCO is freerunning.
The register settings for these two cases are almost the same. The only difference is that, if there is no input
signal, then the channel will be disabled and powered-down by default. In order to force enable the channel,
write a 1 to bit 7 and a 0 to bit 6 of register 0x14. This forces the signal detect to be active and enables the
selected channel.
The remainder of the register write sequence is designed to disable the phase-locked loop so that the VCO can
free run.
First write a 1 to bit 3 of register 0x09, then 0x0 to bits 1:0 of register 0x1b. This disables the charge pump for
the phase-locked loop.
Next write a 1 to bit 2 of register 0x09. This enables the VCO divider override. Then set the VCO divider ratio by
writing to register 0x18 as shown in Table 8. For an output frequency of approximately 10.3125 GHz, set the
divider ratio to 1 by writing 0x0 to bits 6:4 of register 0x18. Do not clear bit 3 when you write a 1 to bit 2 of
register 0x09.
Now write a 1 to bit 7 of register 0x09. This enables the VCO CAP DAC override. Write the desired VCO cap
count to register 0x08, bits 4:0. The mapping of VCO frequencies to cap count will vary somewhat from part to
part. The VCO cap count should be set to 0x0c to yield an output VCO frequency of approximately 10.3125 GHz.
Do not clear bits 3 and 2 when you write a 1 to bit 7 of register 0x09.
Now write a 1 to bit 6 of register 0x09. This enables the VCO LPF DAC which can generate a VCO control
voltage internally to the DS100DF410. Once the LPF DAC is enabled, write the desired value of the LPF DAC
output in register 0x1f, bits 4:0. For an output VCO frequency of approximately 10.3125 GHz, set the LPF DAC
setting to 0x12. Do not clear the remaining bits of register 0x09 when you write a 1 to bit 6.
Now, as above, enable the PRBS generator and set it to the desired bit sequence, then select the output to be
the PRBS generator by setting the output multiplexer. Notice that when this entire sequence has been
completed, bits 7:2 of register 0x09 will all be set. The default value of register 0x09 is 0x00, so you can clear all
the overrides when you are ready to return to normal operation by writing 0x00 to register 0x09.
30
Submit Documentation Feedback
Copyright © 2012–2013, Texas Instruments Incorporated
Product Folder Links: DS100DF410
DS100DF410
www.ti.com
SNLS399A – JANUARY 2012 – REVISED FEBRUARY 2013
The VCO frequency in free-run will vary somewhat from part to part. In order to determine exact values of the
CAP DAC and LPF DAC settings, it will be necessary to directly measure the VCO frequency using some sort of
frequency-measurement device such as a frequency counter or a spectrum analyzer. When the VCO is set to
free-run mode as above, you can select the VCO I-clock (in-phase clock) to be the output as shown in Table 7.
You can measure the frequency of the VCO I-clock while adjusting the CAP DAC and LPF DAC values until the
VCO I-clock frequency is acceptable for your application. Then you can once again select the PRBS generator
as the output using the output multiplexer selection field.
Using the Internal Eye Opening Monitor
Register 0x11, bits 7:6 and bit 5, Register 0x22, bit 7, Register 0x24, bit 7 and bit 0, Register 0x25, Register
0x26, Register 0x27, Register 0x28, and Register 0x2a
The DS100DF410 includes an internal eye opening monitor. The eye opening monitor is used by the retimer to
compute a figure of merit for automatic adaptation of the CTLE and the DFE. It can also be controlled and
queried through the SMBus by a system controller.
The eye opening monitor produces error hit counts for settable phase and voltage offsets of the comparator in
the retimer. This is similar to the way many Bit Error Rate Test Sets measure eye opening. At each phase and
amplitude offset setting, the eye opening monitor determines the nominal bit value (“0” or “1”) using its primary
comparator. This is the bit value that is resynchronized to the recovered clock and presented at the output of the
DS100DF410. The eye opening monitor also determines the bit value detected by the offset comparator. This
information yields an eye contour. Here's how this works.
If the offset comparator is offset in voltage by an amount larger than the vertical eye opening, for example, then
the offset comparator will always decide that the current bit has a bit value of “0”. When the bit is really a “1”, as
determined by the primary comparator, this is considered a bit error. The number of bit errors is counted for a
settable interval at each setting of the offset phase and voltage of the offset comparator. These error counts can
be read from registers 0x25 and 0x26 for sequential phase and voltage offsets. These error counts for each
phase and voltage offsets form a 64 X 64 point array. A surface or contour plot of the error hit count versus
phase and voltage offset produces an eye diagram, which can be plotted by external software.
The eye opening monitor works in two modes. In the first, only the horizontal and vertical eye openings are
measured. The eye opening monitor first sweeps its variable-phase clock through one unit interval with the
comparison voltage set to the mid point of the signal. This determines the midpoint of the horizontal eye opening.
The eye opening monitor then sets its variable phase clock to the midpoint of the horizontal eye opening and
sweeps its comparison voltage. These two measurements determine the horizontal and vertical eye openings.
The horizontal eye opening value is read from register 0x27 and the vertical eye opening from register 0x28.
Both values are single byte values.
The measurement of horizontal and vertical eye opening is very fast. The speed of this measurement makes it
useful for determining the adaptation figure of merit. In normal operation, the HEO and VEO are automatically
measured periodically to determine whether the DS100DF410 is still in lock. Reading registers 0x27 and 0x28
will yield the most-recently measured HEO and VEO values.
In normal operation, the eye monitor circuitry is powered down most of the time to save power. When the eye is
to be measured under external control, it must first be enabled by writing a 0 to bit 5 of register 0x11. The default
value of this bit is 1, which powers down the eye monitor except when it is powered-up periodically by the CDR
state machine and used to test CDR lock. The eye monitor must be powered up to measure the eye under
external SMBus control.
Bits 7:6 of register 0x11 are also used during eye monitor operation to set the EOM voltage range. This is
described below. A single write to register 0x11 can set both bit 5 and bits 7:6 in one operation.
Register 0x3e, bit 7, enables horizontal and vertical eye opening measurements as part of the lock validation
sequence. When this bit is set, the CDR state machine periodically uses the eye monitor circuitry to measure the
horizontal and vertical eye opening. If the eye openings are too small, according to the pre-determined
thresholds in register 0x6a, then the CDR state machine declares lock loss and begins the lock acquisition
process again. For SMBus acquisition of the internal eye, this lock monitoring function must be disabled. Prior to
overriding the EOM by writing a 1 to bit 0 of register 0x24, disable the lock monitoring function by writing a 0 to
bit 7 of register 0x3e. Once the eye has been acquired, you can reinstate HEO and VEO lock monitoring by once
again writing a 1 to bit 7 of register 0x3e.
Submit Documentation Feedback
Copyright © 2012–2013, Texas Instruments Incorporated
Product Folder Links: DS100DF410
31
DS100DF410
SNLS399A – JANUARY 2012 – REVISED FEBRUARY 2013
www.ti.com
Under external SMBus control, the eye opening monitor can be programmed to sweep through all its 64 states of
phase and voltage offset autonomously. This mode is initiated by setting register 0x24, bit 7, the fast_eom mode
bit. Register 0x22, bit 7, the eom_ov bit, should be cleared in this mode.
When the fast_eom bit is set, the eye opening monitor operation is initiated by setting bit 0 of register 0x24,
which is self-clearing. As soon as this bit is set, the eye opening monitor begins to acquire eye data. The results
of the eye opening monitor error counter are stored in register 0x25 and 0x26. In this mode the eye opening
monitor results can be obtained by repeated multi-byte reads from register 0x25. It is not necessary to read from
register 0x26 for a multi-byte read. As soon as the eight most significant bits are read from register 0x25, the
eight least significant bits for the current setting are loaded into register 0x25 and they can be read immediately.
As soon as the read of the eight most significant bits has been initiated, the DS100DF410 sets its phase and
voltage offsets to the next setting and starts its error counter again. The result of this is that the data from the eye
opening monitor is available as quickly as it can be read over the SMBus with no further register writes required.
The external controller just reads the data from the DS100DF410 over the SMBus as fast as it can. When all the
data has been read, the DS100DF410 clears the eom_start bit.
If multi-byte reads are not used, meaning that the device is addressed each time a byte is read from it, then it is
necessary to read register 0x25 to get the MSB (the eight most significant bits) and register 0x26 to get the LSB
(the eight least significant bits) of the current eye monitor measurement. Again, as soon as the read of the MSB
has been initiated, the DS100DF410 sets its phase and voltage offsets to the next setting and starts its error
counter again. In this mode both registers 0x25 and 0x26 must be read in order to get the eye monitor data. The
eye monitor data for the next set of phase and voltage offsets will not be loaded into registers 0x25 and 0x26
until both registers have been read for the current set of phase and voltage offsets.
In all eye opening monitor modes, the amount of time during which the eye opening monitor accumulates eye
opening data can be set by the value of register 0x2a. In general, the greater this value the longer the
accumulation time. When this value is set to its maximum possible value of 0xff, the maximum number of
samples acquired at each phase and amplitude offset is approximately 218. Even with this setting, the eye
opening monitor values can be read from the SMBus with no delay. The eye opening monitor operation is
sufficiently fast that the SMBus read operation cannot outrun it.
The eye opening is measured at the input to the data comparator. At this point in the data path, a significant
amount of gain has been applied to the signal by the CTLE. In many cases, the vertical eye opening as
measured by the EOM will be on the order of 400 to 500 mV peak-to-peak. The secondary comparator, which is
used to measure the eye opening, has an adjustable voltage range from ±100 mV to ±400 mV. The EOM voltage
range is normally set by the CDR state machine during lock and adaptation, but the range can be overridden by
writing a two-bit code to bits 7:6 of register 0x11. The values of this code and the corresponding EOM voltage
ranges are shown in Table 9.
Table 9. EOM Voltage Range vs. Bits 7:6 of Register 0x11
Value in Bits 7:6 of Register 0x11
EOM Voltage Range (± mV)
0x0
±100
0x1
±200
0x2
±300
0x3
±400
Note that the voltage ranges shown in Table 9 are the voltage ranges of the signal at the input to the data path
comparator. These values are not directly equivalent to any observable voltage measurements at the input to the
DS100DF410 . Note also that if the EOM voltage range is set too small the voltage sweep of the secondary
comparator may not be sufficient to capture the vertical eye opening. When this happens the eye boundaries will
be outside the vertical voltage range of the eye measurement.
Overriding the DFE Tap Weights and Polarities
Register 0x11, bits 3:0, Register 0x12, bit 7 and bits 4:0, Register 0x15, bit 7, Register 0x1e, bit 3, Register 0x20,
Register 0x21, Register 0x23, bit 6, Register 0x24, bit 2, Register 0x2f, bit 0, and Registers 0x71–0x75
For the DS100DF410 the DFE tap weights and polarities are normally set automatically by the adaptation
procedure. These values can be overridden by the user if desired.
32
Submit Documentation Feedback
Copyright © 2012–2013, Texas Instruments Incorporated
Product Folder Links: DS100DF410
DS100DF410
www.ti.com
SNLS399A – JANUARY 2012 – REVISED FEBRUARY 2013
Prior to overriding the DFE tap weights and polarities, the dfe_ov bit, bit 6 of register 0x23, should be set. This bit
is set by default. In order for the DFE tap weights and polarities to be applied to the input signal, bit 3 of register
0x1e, the dfe_PD bit, must be set to 0. It is necessary to change the default settings of these registers, because
the DFE is powered down by default.
It is also necessary to set bit 7 of register 0x15 in order to manually set the DFE tap weights. This bit is cleared
by default.
Bits 4:0 of register 0x12 set the five-bit weight for DFE tap 1. The first DFE tap has a five-bit setting, while the
other taps are set using four bits. Often the first DFE tap has the largest effect in improving the bit error rate of
the system, which is why this tap has a five-bit weight setting.
The polarity of the tap weight for tap 1 is set using bit 7 of the same register, register 0x12. The polarity is set to
0 by default, which corresponds to a negative algebraic sign for the tap.
The other four taps are set using four-bit fields in registers 0x20 and 0x21. The polarities of these taps are set by
bits 3:0 in register 0x11. These tap polarities are all set to 0 by default.
As is the case for the CTLE settings, if changing the DFE tap weights or polarities causes the DS100DF410 to
lose lock, it may readapt its CTLE in order to reacquire lock. If this occurs, the CTLE settings may appear to
change spontaneously when the DFE tap weights are changed. The mechanism is the same as that described
above for the CTLE boost settings.
When the DS100DF410 is set to adapt mode 2 or 3 using bits 6:5 of register 0x31, it will automatically adapt its
DFE whenever its CDR state machine is reset. This occurs when the user manually resets the CDR state
machine using bits 3:2 of register 0x0a, or when a signal is first presented at the input to the channel when the
channel is in an unlocked state.
Regardless of the adapt mode, DFE adaptation can be initiated under SMBus control. Because the DFE tap
weight registers are used by the DFE state machine during adaptation, they may be reset prior to adaptation,
which can cause the adaptation to fail. The DFE tap observation registers can be used to prevent this.
Prior to initiating DFE adaptation under SMBus control, write the starting values of the DFE tap settings into the
DFE tap weight registers, registers 0x11, 0x12, 0x20, and 0x21. The values can be read from the observation
registers, registers 0x71 through 0x75. For each DFE tap, read the current value in the observation register. Both
the polarities and the tap weights are contained in the observation registers as shown in Table 3. For each DFE
tap, write the current tap polarity and tap weight into the DFE tap register. Once all these values have been
written, DFE adaptation can be initiated and it will proceed normally. If the DS100DF410 fails to find a set of DFE
tap weights producing a better adaptation figure of merit than the starting tap weights, the starting tap weights
will be retained and used.
CTLE adaptation can also be initiated manually. Setting and then clearing bit 0 of register 0x2f will initiate
adaptation of the CTLE. As with the DFE, if the DS100DF410 fails to find a set of CTLE settings that produce a
better adaptation figure of merit than the starting CTLE values, the starting CTLE values will be retained and
used.
Enabling Slow Rise/Fall Time on the Output Driver
Register 0x18, bit 2
Normally the rise and fall times of the output driver of the DS100DF410 are set by the slew rate of the output
transistors. By default, the output transistors are biased to provide the maximum possible slew rate, and hence
the minimum possible rise and fall times. In some applications, slower rise and fall times may be desired. For
example, slower rise and fall times may reduce the amplitude of electromagnetic interference (EMI) produced by
a system.
Setting bit 2 of register 0x18 will adjust the output driver circuitry to increase the rise and fall times of the signal.
Setting this bit will approximately double the nominal rise and fall times of the DS100DF410 output driver. This bit
is cleared by default.
Inverting the Output Polarity
Register 0x1f, bit 7
In some systems, the polarity of the data does not matter. In systems where it does matter, it is sometimes
necessary, for the purposes of trace routing, for example, to invert the normal polarities of the data signals.
Submit Documentation Feedback
Copyright © 2012–2013, Texas Instruments Incorporated
Product Folder Links: DS100DF410
33
DS100DF410
SNLS399A – JANUARY 2012 – REVISED FEBRUARY 2013
www.ti.com
The DS100DF410 can invert the polarity of the data signals by means of a register write. Writing a 1 to bit 7 of
register 0x1f inverts the polarity of the output signal for the selected channel. This can provide additional flexibility
in system design and board layout.
Overriding the Figure of Merit for Adaptation
Register 0x2c, bits 5:4, Register 0x31, bits 6:5, Register 0x6b, Register 0x6c, Register 0x6d, and Register 0x6e,
bits 7 and 6
The default figure of merit for both the CTLE and DFE adaptation is simple. The horizontal and vertical eye
openings are measured for each CTLE boost setting or set of DFE tap weights and polarities. The vertical eye
opening is scaled to a constant reference vertical eye opening and the smaller of the horizontal or vertical eye
opening is taken as the figure of merit for that set of equalizer settings. The objective is to adapt the equalizer to
a point where the horizontal and vertical eye openings are both as large as possible. This usually provides
optimum bit error rate performance for most transmission channels.
In some systems the adaptation can reach a better setting if only the horizontal or vertical eye opening is used to
compute the figure of merit rather than using both. This will be system-dependent and the user must determine
through experiment whether this provides better adaptation in the user's system. For the DS100DF410, the DFE
figure of merit type can be set using register 0x2c, bits 5:4. The value of this two-bit field versus the configured
figure of merit type is shown in Table 10.
Table 10. Figure of Merit Type Setting
Register 0x2c, bits 5:4
Figure of Merit Type
0x0
Both HEO and VEO are used
0x1
Only HEO is used
0x2
Only VEO is used
0x3
Both HEO and VEO are used (default)
The CTLE figure of merit type is selected using the two-bit field in register 0x31, bits 6:5, with the same effect as
in Table 10.
For some transmission media the adaptation can reach a better setting if a different figure of merit is used. The
DS100DF410 includes the capability of adapting based on a configurable figure of merit. The configurable figure
of merit is structured as shown in the equation below.
FOM = (HEO – b) X a + (VEO – c) x (1 – a)
In this equation, HEO is horizontal eye opening, VEO is vertical eye opening, FOM is the figure of merit, and the
factors a, b, and c are set using registers 0x6b, 0x6c, and 0x6d respectively.
In order to use the configurable figure of merit, the enable bits must be set. To use the configurable figure of
merit for the CTLE adaptation, set bit 7 of register 0x6e, the en_new_fom_ctle bit. To use the configurable figure
of merit for the DFE adaptation set bit 6 of register 0x6e, the en_new_fom_dfe bit. The same scaling factors are
used for both CTLE and DFE adaptation when the configurable figure of merit is enabled.
Setting the Rate and Subrate for Lock Acquisition
Register 0x2f, bits 7:6 and 5:4
The rate and subrate settings, which configure the set of VCO frequencies to which the VCO coarse tuning is to
be calibrated are set using channel register 0x2f. Bits 7:6 are RATE<1:0>, and bits 5:4 are SUBRATE<1:0>.
Setting the Adaptation/Lock Mode
Register 0x31, bits 6:5, and Register 0x33, bits 7:4 and 3:0, Register 0x34, bits 3:0, Register 0x35, bits 4:0,
Register 0x3e, bit 7, and Register 0x6a
There are four adaptation modes available in the DS100DF410.
• Mode 0: The user is responsible for setting the CTLE and DFE values. this mode is used if the transmission
channel response is fixed.
• Mode 1: Only the CTLE is adapted to equalize the transmission channel. The DFE is enabled but the tap
weights are all set to 0. This mode is primarily used for smoothly-varying high-loss transmission channels
34
Submit Documentation Feedback
Copyright © 2012–2013, Texas Instruments Incorporated
Product Folder Links: DS100DF410
DS100DF410
www.ti.com
•
•
SNLS399A – JANUARY 2012 – REVISED FEBRUARY 2013
such as cables and simple PCB traces.
Mode 2: In this mode, both the CTLE and the DFE are adapted to compensate for additional loss, reflections,
and crosstalk in the input transmission channel.
– The maximum DFE tap weights can be constrained using register 0x34, bits 3:0, and register 0x35, bits
4:0 as shown in Table 5.
Mode 3: In this mode, both the CTLE and DFE are adapted as in mode 2. However, in mode 3, more
emphasis is placed on the DFE setting. This mode may give better results for high crosstalk transmission
channels.
Bits 6:5 of register 0x31 determine the adaptation mode to be used. The mapping of these register bits to the
adaptation algorithm is shown in Table 5.
Table 11. DS100DF410 Adaptation Algorithm Settings
Register 0x31, Bit 6
adapt_mode[1]
Register 0x31, Bit 5
adapt_mode[0]
Adapt Mode Setting <1:0>
Adaptation Algorithm
0
0
00
No Adaptation
0
1
01
Adapt CTLE Until Optimum
(Default)
1
0
10
Adapt CTLE Until Optimum then
DFE, then CTLE Again
1
1
11
Adapt CTLE Until Lock, then
DFE, the CTLE Again
By default the DS100DF410 requires that the equalized internal eye exhibit horizontal and vertical eye openings
greater than a pre-set minimum in order to declare a successful lock. The minimum values are set in register
0x6a.
The DS100DF410 continuously monitors the horizontal and vertical eye openings while it is in lock. If the eye
opening falls below the threshold set in register 0x6a, the DS100DF410 will declare a loss of lock.
The continuous monitoring of the horizontal and vertical eye openings may be disabled by clearing bit 7 of
register 0x3e.
Initiating Adaptation
Register 0x24, bit 2, and Register 0x2f, bit 0
When the DS100DF410 becomes unlocked, it will automatically try to acquire lock. If an adaptation mode is
selected using bits 6:5 in register 0x31, the DS100DF410 will also try to adapt its CTLE and its DFE.
Adaptation can also be initiated by the user. CTLE adaptation can be initiated by setting and then clearing
register 0x2f, bit 0. DFE adaptation can be initiated by setting and then clearing bit 2 of register 0x24.
Setting the Reference Enable Mode
Register 0x36, bits 5:4
Register 0x36, bits 5:4, are the ref_mode<1:0> bits. These bits should be set to a value of 2'b11. Note that this is
not the default. The reference mode must be set prior to using the DS100DF410.
A 25 MHz reference clock signal must be provided on the reference in pin (pin 19). The use of the reference
clock in the DS100DF410 is explained below.
First, the reference clock allows the DS100DF410 to calibrate its VCO frequency at power-up and upon reset.
This enables the DS100DF410 to determine the optimum coarse VCO tuning setting a-priori, which makes phase
lock much faster. The DS100DF410 is not required to tune through the available coarse VCO tuning settings as it
tries to acquire lock to an input signal. It can select the correct setting immediately.
Second, if the DS100DF410 loses lock for some reason and the VCO drifts from its phase-locked frequency, the
DS1010DF410 can detect this very quickly using the reference clock. Detecting an out-of-lock condition quickly
allows the DS100DF410 to raise an interrupt indicating that it has lost lock quickly, which the system controller
can then service to correct the problem quickly.
Submit Documentation Feedback
Copyright © 2012–2013, Texas Instruments Incorporated
Product Folder Links: DS100DF410
35
DS100DF410
SNLS399A – JANUARY 2012 – REVISED FEBRUARY 2013
www.ti.com
Finally, some data signals with large jitter spurs in their frequency spectra can cause the DS1100DF410 to false
lock. This occurs when the data pattern exhibits strong discrete frequency components in its frequency spectrum,
or when the data pattern has a lot of periodic jitter imposed on it. If you look at such a signal in the frequency
domain using a spectrum analyzer, it will clearly show “spurs” close in to the fundamental data rate frequency.
These spurs can cause the DS100DF410 to false lock.
Using the 25 MHz reference clock, the DS100DF410 can detect when it is locked to a jitter spur. When this
happens, the DS100DF410 will re-initiate the adaptation and lock sequence until it locks to the correct data rate.
This provides immunity to false lock conditions.
The reference clock mode is set by a two-bit field, register 0x36, bits 5:4. This field should always be set to a
value of 3 or 2'b11.
Overriding the CTLE Settings Used for CTLE Adaptation
Register 0x2c, bits 3:0, Register 0x2f, bit 3, Register 0x39, bits 4:0, and Registers 0x50-0x5f
The CTLE adaptation algorithm operates by setting the CTLE boost stage controls to a set of pre-determined
boost settings, each of which provides progressively more high-frequency boost. At each stage in the adaptation
process, the DS100DF410 attempts to phase lock to the equalized signal. If the phase lock succeeds, the
DS100DF410 measures the horizontal and vertical eye openings using the internal eye monitor circuit. The
DS100DF410 computes a figure of merit for the eye opening and compares it to the previous best value of the
figure of merit. While the figure of merit continues to improve, the DS100DF410 continues to try additional values
of the CTLE boost setting until the figure of merit ceases to improve and begins to degrade. When the figure of
merit starts to degrade, the DS100DF410 still continues to try additional CTLE settings for a pre-determined trial
count called the “look-beyond” count, and if no improvement in the figure of merit results, it resets the CTLE
boost values to those that produced the best figure of merit. The resulting CTLE boost values are then stored in
register 0x03. The “look-beyond” count is configured by the value in register 0x2c, bits 3:0. The value is 0x2 by
default.
The set of boost values used as candidate values during CTLE adaptation are stored as bit fields in registers
0x40-0x5f. The default values for these settings are shown in Table 12. These values may be overridden by
setting the corresponding register values over the SMBus. If these values are overridden, then the next time the
CTLE adaptation is performed the set of CTLE boost values stored in these registers will be used for the
adaptation. Resetting the channel registers by setting bit 2 of channel register 0x00 will reset the CTLE boost
settings to their defaults. So will power-cycling the DS100DF410.
Table 12. CTLE Settings for Adaptation
Register (Hex)
Bits 7:6 (CTLE
Stage 0)
Bits 5:4 (CTLE
Stage 1)
Bits 3:2 (CTLE
Stage 2)
Bits 1:0 (CTLE
Stage 3)
CTLE Boost
String
CTLE Adaptation
Index
40
0
0
0
0
0000
0
41
0
0
0
1
0001
1
42
0
0
1
0
0010
2
43
0
1
0
0
0100
3
44
1
0
0
0
1000
4
45
0
0
2
0
0020
5
46
0
0
0
2
0002
6
47
2
0
0
0
2000
7
48
0
0
0
3
0003
8
49
0
0
3
0
0030
9
4A
0
3
0
0
0300
10
4B
1
0
0
1
1001
11
4C
1
1
0
0
1100
12
4D
3
0
0
0
3000
13
4E
1
2
0
0
1200
14
4F
2
1
0
0
2100
15
50
2
0
2
0
2020
16
51
2
0
0
2
2002
17
36
Submit Documentation Feedback
Copyright © 2012–2013, Texas Instruments Incorporated
Product Folder Links: DS100DF410
DS100DF410
www.ti.com
SNLS399A – JANUARY 2012 – REVISED FEBRUARY 2013
Table 12. CTLE Settings for Adaptation (continued)
Register (Hex)
Bits 7:6 (CTLE
Stage 0)
Bits 5:4 (CTLE
Stage 1)
Bits 3:2 (CTLE
Stage 2)
Bits 1:0 (CTLE
Stage 3)
CTLE Boost
String
CTLE Adaptation
Index
52
2
2
0
0
2200
18
53
1
0
1
2
1012
19
54
1
1
0
2
1102
20
55
2
0
3
0
2030
21
56
2
3
0
0
2300
22
57
3
0
2
0
3020
23
58
1
1
1
3
1113
24
59
1
1
3
1
1131
25
5A
1
2
2
1
1221
26
5B
1
3
1
1
1311
27
5C
3
1
1
1
3111
28
5D
2
1
2
1
2121
29
5E
2
1
1
2
2112
30
5F
2
2
1
1
2211
31
As an alternative to, or in conjunction with, writing the CTLE boost setting registers 0x40 through 0x5f, it is
possible to set the starting CTLE boost setting index. To override the default setting, which is 0, set bit 3 of
register 0x2f. When this bit is set, the starting index for adaptation comes from register 0x39, bits 4:0. This is the
index into the CTLE settings table in registers 0x40 through 0x5f. When this starting index is 0, which is the
default, CTLE adaptation starts at the first setting in the table, the one in register 0x40, and continues until the
optimum FOM is reached.
Setting the Output Differential Voltage
Register 0x2d, bits 2:0
There are eight levels of output differential voltage available in the DS100DF410, from 0.6 V to 1.3 V in 0.1 V
increments. The values drv_sel_vod[2:0] in bits 2:0 of register 0x2d set the output VOD. The available VOD
settings and the corresponding values of this bit field are shown in Table 13.
Table 13. VOD Settings
Bit 2, drv_sel_vod[2]
Bit 1, drv_sel_vod[1]
Bit 0, drv_sel_vod[0]
Selected VOD (V, peak-to-peak,
differential)
0
0
0
0.6
0
0
1
0.7
0
1
0
0.8
0
1
1
0.9
1
0
0
1.0
1
0
1
1.1
1
1
0
1.2
1
1
1
1.3
Setting the Output De-emphasis Setting
Register 0x15, bits 2:0 and bit 6
Fifteen output de-emphasis settings are available in the DS100DF410, ranging from 0 dB to -12 dB. The deemphasis values come from register 0x15, bits 2:0, which make up the bit field dvr_dem<2:0>, and register 0x15,
bit 6, which is the de-emphasis range bit.
The available driver de-emphasis settings and the mapping to these bits are shown in Table 14.
Submit Documentation Feedback
Copyright © 2012–2013, Texas Instruments Incorporated
Product Folder Links: DS100DF410
37
DS100DF410
SNLS399A – JANUARY 2012 – REVISED FEBRUARY 2013
www.ti.com
Table 14. Driver De-Emphasis Settings
Register 0x15, Bit 2,
dvr_dem[2]
Register 0x15, Bit 1,
drv_dem[1]
Register 15, Bit 0,
drv_dem[0]
Register 0x15, Bit 6,
drv_dem_range
De-emphasis Setting
(dB)
0
0
0
X
0.0
0
0
1
1
-0.9
0
0
1
0
-1.5
0
1
0
1
-2.0
0
1
1
1
-2.8
1
0
0
1
-3.3
0
1
0
0
-3.5
1
0
1
1
-3.9
1
1
0
1
-4.5
0
1
1
0
-5.0
1
1
1
1
-5.6
1
0
0
0
-6.0
1
0
1
0
-7.5
1
1
0
0
-9.0
1
1
1
0
-12.0
38
Submit Documentation Feedback
Copyright © 2012–2013, Texas Instruments Incorporated
Product Folder Links: DS100DF410
PACKAGE OPTION ADDENDUM
www.ti.com
21-Mar-2013
PACKAGING INFORMATION
Orderable Device
Status
(1)
Package Type Package Pins Package Qty
Drawing
Eco Plan
Lead/Ball Finish
(2)
MSL Peak Temp
Op Temp (°C)
Top-Side Markings
(3)
(4)
DS100DF410SQ/NOPB
ACTIVE
WQFN
RHS
48
1000
Green (RoHS
& no Sb/Br)
CU SN
Level-3-260C-168 HR
100DF410
DS100DF410SQE/NOPB
ACTIVE
WQFN
RHS
48
250
Green (RoHS
& no Sb/Br)
CU SN
Level-3-260C-168 HR
100DF410
(1)
The marketing status values are defined as follows:
ACTIVE: Product device recommended for new designs.
LIFEBUY: TI has announced that the device will be discontinued, and a lifetime-buy period is in effect.
NRND: Not recommended for new designs. Device is in production to support existing customers, but TI does not recommend using this part in a new design.
PREVIEW: Device has been announced but is not in production. Samples may or may not be available.
OBSOLETE: TI has discontinued the production of the device.
(2)
Eco Plan - The planned eco-friendly classification: Pb-Free (RoHS), Pb-Free (RoHS Exempt), or Green (RoHS & no Sb/Br) - please check http://www.ti.com/productcontent for the latest availability
information and additional product content details.
TBD: The Pb-Free/Green conversion plan has not been defined.
Pb-Free (RoHS): TI's terms "Lead-Free" or "Pb-Free" mean semiconductor products that are compatible with the current RoHS requirements for all 6 substances, including the requirement that
lead not exceed 0.1% by weight in homogeneous materials. Where designed to be soldered at high temperatures, TI Pb-Free products are suitable for use in specified lead-free processes.
Pb-Free (RoHS Exempt): This component has a RoHS exemption for either 1) lead-based flip-chip solder bumps used between the die and package, or 2) lead-based die adhesive used between
the die and leadframe. The component is otherwise considered Pb-Free (RoHS compatible) as defined above.
Green (RoHS & no Sb/Br): TI defines "Green" to mean Pb-Free (RoHS compatible), and free of Bromine (Br) and Antimony (Sb) based flame retardants (Br or Sb do not exceed 0.1% by weight
in homogeneous material)
(3)
MSL, Peak Temp. -- The Moisture Sensitivity Level rating according to the JEDEC industry standard classifications, and peak solder temperature.
(4)
Only one of markings shown within the brackets will appear on the physical device.
Important Information and Disclaimer:The information provided on this page represents TI's knowledge and belief as of the date that it is provided. TI bases its knowledge and belief on information
provided by third parties, and makes no representation or warranty as to the accuracy of such information. Efforts are underway to better integrate information from third parties. TI has taken and
continues to take reasonable steps to provide representative and accurate information but may not have conducted destructive testing or chemical analysis on incoming materials and chemicals.
TI and TI suppliers consider certain information to be proprietary, and thus CAS numbers and other limited information may not be available for release.
In no event shall TI's liability arising out of such information exceed the total purchase price of the TI part(s) at issue in this document sold by TI to Customer on an annual basis.
Addendum-Page 1
Samples
PACKAGE MATERIALS INFORMATION
www.ti.com
26-Mar-2013
TAPE AND REEL INFORMATION
*All dimensions are nominal
Device
Package Package Pins
Type Drawing
SPQ
Reel
Reel
A0
Diameter Width (mm)
(mm) W1 (mm)
B0
(mm)
K0
(mm)
P1
(mm)
W
Pin1
(mm) Quadrant
DS100DF410SQ/NOPB
WQFN
RHS
48
1000
330.0
16.4
7.3
7.3
1.3
12.0
16.0
Q1
DS100DF410SQE/NOPB
WQFN
RHS
48
250
178.0
16.4
7.3
7.3
1.3
12.0
16.0
Q1
Pack Materials-Page 1
PACKAGE MATERIALS INFORMATION
www.ti.com
26-Mar-2013
*All dimensions are nominal
Device
Package Type
Package Drawing
Pins
SPQ
Length (mm)
Width (mm)
Height (mm)
DS100DF410SQ/NOPB
WQFN
RHS
48
1000
367.0
367.0
38.0
DS100DF410SQE/NOPB
WQFN
RHS
48
250
213.0
191.0
55.0
Pack Materials-Page 2
MECHANICAL DATA
RHS0048A
SQA48A (Rev B)
www.ti.com
IMPORTANT NOTICE
Texas Instruments Incorporated and its subsidiaries (TI) reserve the right to make corrections, enhancements, improvements and other
changes to its semiconductor products and services per JESD46, latest issue, and to discontinue any product or service per JESD48, latest
issue. Buyers should obtain the latest relevant information before placing orders and should verify that such information is current and
complete. All semiconductor products (also referred to herein as “components”) are sold subject to TI’s terms and conditions of sale
supplied at the time of order acknowledgment.
TI warrants performance of its components to the specifications applicable at the time of sale, in accordance with the warranty in TI’s terms
and conditions of sale of semiconductor products. Testing and other quality control techniques are used to the extent TI deems necessary
to support this warranty. Except where mandated by applicable law, testing of all parameters of each component is not necessarily
performed.
TI assumes no liability for applications assistance or the design of Buyers’ products. Buyers are responsible for their products and
applications using TI components. To minimize the risks associated with Buyers’ products and applications, Buyers should provide
adequate design and operating safeguards.
TI does not warrant or represent that any license, either express or implied, is granted under any patent right, copyright, mask work right, or
other intellectual property right relating to any combination, machine, or process in which TI components or services are used. Information
published by TI regarding third-party products or services does not constitute a license to use such products or services or a warranty or
endorsement thereof. Use of such information may require a license from a third party under the patents or other intellectual property of the
third party, or a license from TI under the patents or other intellectual property of TI.
Reproduction of significant portions of TI information in TI data books or data sheets is permissible only if reproduction is without alteration
and is accompanied by all associated warranties, conditions, limitations, and notices. TI is not responsible or liable for such altered
documentation. Information of third parties may be subject to additional restrictions.
Resale of TI components or services with statements different from or beyond the parameters stated by TI for that component or service
voids all express and any implied warranties for the associated TI component or service and is an unfair and deceptive business practice.
TI is not responsible or liable for any such statements.
Buyer acknowledges and agrees that it is solely responsible for compliance with all legal, regulatory and safety-related requirements
concerning its products, and any use of TI components in its applications, notwithstanding any applications-related information or support
that may be provided by TI. Buyer represents and agrees that it has all the necessary expertise to create and implement safeguards which
anticipate dangerous consequences of failures, monitor failures and their consequences, lessen the likelihood of failures that might cause
harm and take appropriate remedial actions. Buyer will fully indemnify TI and its representatives against any damages arising out of the use
of any TI components in safety-critical applications.
In some cases, TI components may be promoted specifically to facilitate safety-related applications. With such components, TI’s goal is to
help enable customers to design and create their own end-product solutions that meet applicable functional safety standards and
requirements. Nonetheless, such components are subject to these terms.
No TI components are authorized for use in FDA Class III (or similar life-critical medical equipment) unless authorized officers of the parties
have executed a special agreement specifically governing such use.
Only those TI components which TI has specifically designated as military grade or “enhanced plastic” are designed and intended for use in
military/aerospace applications or environments. Buyer acknowledges and agrees that any military or aerospace use of TI components
which have not been so designated is solely at the Buyer's risk, and that Buyer is solely responsible for compliance with all legal and
regulatory requirements in connection with such use.
TI has specifically designated certain components as meeting ISO/TS16949 requirements, mainly for automotive use. In any case of use of
non-designated products, TI will not be responsible for any failure to meet ISO/TS16949.
Products
Applications
Audio
www.ti.com/audio
Automotive and Transportation
www.ti.com/automotive
Amplifiers
amplifier.ti.com
Communications and Telecom
www.ti.com/communications
Data Converters
dataconverter.ti.com
Computers and Peripherals
www.ti.com/computers
DLP® Products
www.dlp.com
Consumer Electronics
www.ti.com/consumer-apps
DSP
dsp.ti.com
Energy and Lighting
www.ti.com/energy
Clocks and Timers
www.ti.com/clocks
Industrial
www.ti.com/industrial
Interface
interface.ti.com
Medical
www.ti.com/medical
Logic
logic.ti.com
Security
www.ti.com/security
Power Mgmt
power.ti.com
Space, Avionics and Defense
www.ti.com/space-avionics-defense
Microcontrollers
microcontroller.ti.com
Video and Imaging
www.ti.com/video
RFID
www.ti-rfid.com
OMAP Applications Processors
www.ti.com/omap
TI E2E Community
e2e.ti.com
Wireless Connectivity
www.ti.com/wirelessconnectivity
Mailing Address: Texas Instruments, Post Office Box 655303, Dallas, Texas 75265
Copyright © 2013, Texas Instruments Incorporated