STMICROELECTRONICS IMSA110-G20S

IMSA110
IMAGE AND SIGNAL PROCESSING SUB–SYSTEM
1-D/2-D SOFTWARE CONFIGURABLE CONVOLVER/FILTER
ON-CHIP PROGRAMMABLE LINE DELAYS (0
— 1120 STAGES)
8-BIT DATA AND 8.5-BIT COEFFICIENT
SLICE
21 MULTIPLY-AND-ACCUMULATE STAGES
1-D (21) OR 2-D (3 x 7) CONVOLUTION WINDOW
ON-CHIP POST PROCESSOR FOR DATA
TRANSFORMATION
FULLY CASCADABLE IN WINDOW SIZE AND
ACCURACY
20 MHZ DATA THROUGHPUT (420 MOPS)
SIGNED/UNSIGNED DATA AND COEFFICIENTS
MICROPROCESSOR INTERFACE
HIGH SPEED CMOS IMPLEMENTATION
TTL COMPATIBLE
SINGLE +5V ± 10% SUPPLY
POWER DISSIPATION < 2.0 WATTS
100 PIN CERAMIC PGA
..
..
..
..
APPLICATIONS
1-D and 2-D digital convolution and correlation
Real time image processing and enhancement
Edge and feature detection
Data transformation and histogram equalisation
Computer vision and robotics
Template matching
Pulse compression
1-D or 2-D interpolation
July 1992
PGA100
(Ceramic Grid Array Package)
ORDERING INFORMATION
Part Number
Package
Clock
Speed
Military/
commercial
IMSA110-G20S
PGA100
20MHz
commercial
1/26
A110-01.TBL
.
.
.
..
.
.
..
..
..
..
IMSA110
Index 1
2
3
4
5
6
7
8
9
10
A
PSRIN
[6]
PSRIN
[4]
PSRIN
[2]
PSRIN
[1]
PSROUT PSROUT PSROUT
[1]
[2]
[5]
COUT
[0]
COUT
[1]
COUT
[6]
B
CIN
[3]
CLK
PSRIN
[7]
PSRIN
[3]
PSROUT
[0]
PSROUT
[6]
COUT
[2]
Vcc
COUT
[7]
C
CIN
[4]
CIN
[2]
CIN
[0]
PSRIN
[5]
GND
PSROUT PSROUT
[3]
[7]
COUT
[4]
GND
COUT
[9]
D
Vcc
GND
CIN
[5]
CIN
[1]
PSRIN
[0]
PSROUT
[4]
COUT
[3]
Vcc
COUT
[8]
COUT
[10]
E
CIN
[8]
CIN
[6]
CIN
[7]
GND
GND
COUT
[5]
COUT
[11]
COUT
[12]
COUT
[13]
COUT
[14]
F
CIN
[9]
CIN
[10]
CIN
[11]
CIN
[12]
Vcc
D[6]
COUT
[16]
Vcc
GND
COUT
[15]
G
CIN
[13]
CIN
[15]
CIN
[17]
GND
ADR
[5]
GND
GND
COUT
[19]
COUT
[18]
COUT
[17]
H
CIN
[14]
CIN
[19]
CIN
[21]
ADR
[2]
ADR
[7]
E2
GND
Vcc
Vcc
COUT
[20]
J
CIN
[16]
CIN
[20]
RESET
ADR
[3]
ADR
[6]
E1
D[2]
D[5]
D[7]
COUT
[21]
K
CIN
[18]
ADR
[0]
ADR
[1]
ADR
[4]
ADR
[8]
W
D[0]
D[1]
D[3]
D[4]
GND
Notes : 1. All VCC pins must be connected to the 5 Volt power supply.
2. All GND pins must be connected to ground.
1. INTRODUCTION
The IMSA110 is a single-chip reconfigurable and
cascadable subsystem suitable for many high
speed image and signal processing applications.
Apart from its powerful multiply-accumulate capability (420 MOPs), the strength of the IMSA110 lies
in its extensive programmable support for data
conditioning and transformation.
2/26
2. DESCRIPTION
The IMSA110 consists of a configurable array of
multiply-accumulators, three programmable length
1120 stage shift registers, a versatile post-processing unit and a microprocessor interface for configuration and control purposes. The comprehensive
on-chip facilities make a single device capable of
dealing with many image processing operations.
A110-01.EPS
PIN CONNECTIONS
IMSA110
Figure 1 : IMSA110 Users Model
ENABLE 1
Asynchronous Functions
ENABLE 2
WRITE
21 x 8-bit
Update coefficient registers
MEM
DATA
8
Decode
logic
21 x 8-bit
Current coefficient registers
9
Backend
look up table
256 x 8-bit data
transformation
look up RAM
USR
LSR
Configuration and
control registers
PCR0
PCR1
PCR2
SCR
ACR
BCR
MMB
OUB
TCR
ADDRESS
CLOCK
RESET
8
PSRIN
D
PSROUT
8
CASCADE
INPUT
1120 stage Programmable
shift register (PSRC)
7-stage
multiply-accumulate
array C
1120 stage Programmable
shift register (PSRB)
7-stage
multiply-accumulate
array B
1120 stage Programmable
shift register (PSRA)
7-stage
multiply-accumulate
array A
22
22
Backend
post-processing unit
(normalization, saturation,
and data transformation)
22
CASCADE
OUTPUT
A110-02.EPS
Control
logic
Synchronous Functions
The IMSA110 has five interfaces through which
data can be transferred, Figure 1. The microprocessor interface allows access to the coefficient
registers, the configuration and status registers,
and the data transformation tables. The remaining
four interfaces allow high speed data input and
output to the IMSA110 and the cascading of several
devices. A typical IMSA110 system is shown in
Figure 3. If N devices are used in the cascade, they
can be configured, entirely under software control,
as a 21N stage 1-D transversal filter or as a 7X by
3Y 2-D window, where X and Y are any integers
satisfying N ≤ XY. For example 4 cascaded devices
can be software configured as: an 84-stage 1-D
filter, a 7 by 12 2-D window, a 28 by 3 2-D window,
or a 14 by 6 2-D window.
The final output of the chip is 22 bits wide in twos
complement format.
Figure 2 shows the distribution of the delays inside
the part.
The latency between PSRin and COUT is dependent upon the length of PSRc. For example, with
PSRc set to 0, and all coefficients set to zero except
CR0c[6] (so the data passes through all MAC
stages), the COUT bus will correspond to the
PSRin bus delayed by 47 clock cycles.
The latency between PSRin and PSRout is 5 cycles
PLUS the lengths of PSRc, PSRb and PSRa. If the
shift registers are bypassed by setting SCR[1] to 1
then PSRout will be PSRin delayed by 2 clock
cycles.
The Latency between the cascade input (CIN) and
cascade output (COUT) is 6 cycles. This is shown
lumped at the cascade input and cascade output
pads in Figure 2. Figure 4 gives details of the data
pipelining through the backend datapath.
3/26
IMSA110
Figure 2 : Synchronous Functions of the IMSA110
PSRIN
CR1c coefficient registers 7 x 8 bits
CR0c coefficient registers 7 x 8 bits
1 D
Programmable PSRC
shift register
0 to 1120 stages
D
D
1
1
2
D
3
X
8
X
X
1
D
1
D
8
X
1
D
1
D
22
D
CR1b coefficient registers 7 x 8 bits
CR0b coefficient registers 7 x 8 bits
Programmable PSRB
shift register
0 to 1120 stages
D
D
1
1
2
D
3
X
X
X
1
D
1
D
8
X
1
D
1
D
22
D
CR1a coefficient registers 7 x 8 bits
CR0a coefficient registers 7 x 8 bits
Programmable PSRA
shift register
0 to 1120 stages
D
D
1
1
2
D
3
X
X
X
1
D
1
D
8
X
1
D
1
D
22
D
13
MUX
Backend processing unit
including cascade data path,
normalization, saturation units and
data transformation look up tables
1
2
PSROUT
4/26
D
CIN
cascade input
(see Figure 4 for detail)
22
D 5
1
2
COUT
cascade output
A110-03.EPS
1 D
IMSA110
Figure 3 : A Typical IMSA110 Based System
General purpose
microprocessor
PSRIN
PSROUT
IMSA110
Cascade
IN
Cascade
OUT
PSRIN
PSROUT
IMSA110
Cascade
IN
PSRIN
PSROUT
IMSA110
Cascade
OUT
Cascade
IN
Cascade
OUT
Output
A110-04.EPS
Input
Clock
3. PROGRAMMABLE SHIFT REGISTERS
The three shift registers are 8 bits wide and are
each programmable from 0 up to 1120 clock cycles
in length. The lengths are programmed into control
registers via the microprocessor interface.
Data is clocked into the device via the PSRin bus
(Programmable Shift Register in) at a maximum
rate of 20MHz. On-chip, the input data is then fed
through a pipeline of the three shift registers. The
output of the first shift register passes to the first
7-stage mac array and also to the input of the
second shift register. Having passed through all
three shift registers the data is output on the
PSRout bus and can be used for cascading. Alternatively, as shown in Figure 2 the shift registers can
be bypassed and the input data transferred to the
PSRout bus after two delay stages. This mode can
be controlled via the on-chip control registers and
significantly simplifies software configuration of a
cascade arrangement.
4. MAC ARRAY
As shown in Figure 2, the processing core of the
device consists of a configurable array of multiplyaccumulators (macs). The mac array consists of
three 7-stage transversal filters which can be configured either as a 21-stage linear pipeline or as a
3 × 7 two-dimensional window. The input data is
8 bits wide and is fed to the mac array via three
programmable shift registers.
The output of each shift register is supplied as input
to one of the three 7-stage transversal filters. For
each of the three transversal filters the associated
input data is fed simultaneously to all 7 mac stages.
At each stage the input sample is multiplied by a
coefficient stored in memory, and added to the
output of the previous stage delayed by one clock
cycle. The output of each 7-stage mac is fed, via a
delay stage, to the first stage in the next transversal
filter.
The coefficient word width in the mac array is 8 bits
wide. Two banks of coefficients are provided. At any
instant one set of coefficients is in use within the
mac array. The set in use is defined by the state of
the ‘Current Bank’ bit, ACR[0]. The other set can be
altered via the microprocessor interface. Once a
new set of coefficients has been loaded, the activities of the two coefficient banks can be interchanged without interrupting the flow of data. Alternatively, by setting the ‘continous bank swap’ bit
SCR[0], the two coefficient banks are swapped
automatically after each data input. In this case the
‘Current Bank’ bit only determines which bank is
used first. Both data input and coefficients can be
programmed independently to support twos complement or positive unsigned formats allowing multiple devices to be used as a ‘slice’ in higher accuracy systems.
Within the mac array no truncation or rounding is
performed on the partial products. The mac array
output is fed to the backend post-processing unit
which is responsible for data transformation / normalisation and cascading function.
5. BACKEND POST-PROCESSOR — hardware
description
The Backend Post-Processor consists of four major blocks : The input block (shifter, cascade adder
and rectifier unit),a statistics monitor,the data conditioning unit which itself consists of the data transformation unit and the data normaliser, and the
output block (output adder and multiplexers).
A detailed diagram of the Backend Post-Processor
is given in Figure 4.
All operations performed in the backend are on
twos complement signed numbers unless otherwise stated.
5/26
IMSA110
5.1 Shifter, Cascade Adder and Rectifier
Data from the mac array enters the datapath via a
programmable shifter. The shifter is capable of
arithmetic right shifts (divides) of up to 8 bits with
rounding, and left shifts of up to 8 bits. The size of
this shift is controlled by the status bits BCR0[5-1].
The output of the shifter passes into the cascade
adder where it is added, along with any rounding
generated by the shifter, to either the cascade input
bus (BCR0[0] = 0), or a zero value (BCR[0] = 1).
If the result of this 22-bit signed addition is greater
than 221 - 1, (209715110) then the adder will generate a positive overflow. Likewise, if it is less than
-221, (-209715210) a negative overflow will be generated. In other words, a positive overflow is generated if the result of adding two positive numbers
(both MSBs = 0) is negative (resulting MSB = 1).
Conversely, a negative overflow is generated if the
result of adding two negative numbers (both
MSBs = 1) is positive (MSB = 0). Adding two numbers of different signs cannot cause the adder to
overflow.
The output of the cascade adder can optionally be
full-wave or half wave rectified under the control of
BCR0[7,6]. The output of the rectifier passes onto
the X bus. Overflows on the X bus are signalled to
both the statistics monitor and the data conditioner.
5.2 Statistics Monitor
The statistics monitor allows the user to set up
watch dogs on the dynamics of the data on the X
bus. It cannot affect the data on the X bus. The
statistics gathered provide information on the system behaviour which can be used to ensure correct
data scaling and normalisation. The information is
also useful in the control of the overall system’s
analogue frontend.
Hardware/Functions
The statistics monitor consists of a 24 bit Min/Max
register (MMR), a 24 bit Min/Max Buffer (MMB), a
22 bit Over/UnderShoot Counter (OUC), a 22 bit
Over/UnderShoot Buffer (OUB) and a 22 bit twos
complement comparator.
It can perform one of four functions :
• MAX REGISTER : Capture the maximum value
of data and store it in the MMR.
• MIN REGISTER : Capture the minimum value of
data and store it in the MMR.
6/26
• OVERSHOOT COUNTER : Increment the OUC
each time the data value exceeds the preset
value in the MMR.
• UNDERSHOOT COUNTER : Increment the OUC
each time the data value is less than the preset
value in the MMR.
The mode of operation is determined by the
Max/Min switch BCR1[0], and the Static Threshold
switch BCR1[1].
Operation
Each sample on the X bus is compared against the
threshold stored in the MMR.
If the unit is configured as an overshoot counter
and the data on the X bus exceeds the threshold in
the MMR, then the counter (OUC) is incremented.
If the data is less than or equal to the threshold, then
no action will occur. The OUC is unsigned and will
not wrap around. Thus it behaves as a saturating
counter with a maximum value of 222 - 1,
(3FFFFF16, 419430310). If there is a positive overflow on the X bus, then the counter will increment
since the correct X bus value must exceed the
threshold. Similarly a negative overflow on the X
bus will not increment the counter since the correct
X bus value cannot exceed the preset threshold.
If the unit is configured as an undershoot counter
then the counter will be incremented whenever the
sample is less than the preset threshold. In this
case a negative overflow will cause the counter to
increment.
If the unit is configured as a max register and the
X bus exceeds the current threshold in the MMR,
then the value on the Xbus is loaded into the MMR
and becomes the new threshold and the counter is
incremented. If the threshold is not exceeded then
no action occurs. Thus the value in the MMR is the
maximum value that has appeared on the X bus,
and the value in the OUC has been incremented by
the number of times that the threshold has been
updated.
If the unit is configured as a min register then the
threshold is updated and the counter incremented
whenever the X bus is less than the current threshold.
When operating as a min/max register, overflows
on the X bus can never cause the threshold to be
updated as this would load an erroneous value into
the MMR.
IMSA110
Figure 4 : Detailed Block Diagram of the Backend Post-processing Unit
Clock
cycle
Cascade input pads
From MAC array
22
1
22
Shifter [8:0]
MUX
22
22
2
negative overflow
1
positive overflow
1
1
Rounding
Cascade Adder
22
Rectifier
DATA TRANSFORMATION
UNIT
22
22
STATISTICS MONITOR
Prescaler
Min/max buffer
22
Min/max register
22
X bus
3
Over/under select
8
(Isbs) 2
6
Comparator GT/LT
USR
LSR
Control
Over/undershoot count
22
64 x 32 bit RAM
Over/undershoot buffer
Y bus
[26:22]
DATA NORMALIZER
5
MUX
32
[21:0]
Shifter -2 to 14
Zero data
32
4
from
BCR
Byte select
8
22
1
MUX
22
Rounding
22
Output Adder
22
5
[21:14]
8
8
[7:0]
6
MUX
MUX
[13:8]
8
[7:0]
22
A110-05.EPS
6
8
[21:14]
Cascade output pads
7/26
IMSA110
Overflows
Bit 22 of the MMR records the history of positive
overflows on the X bus. Similarly bit 23 records the
history of negative overflows. These bits in the
MMR are set to zero by writing to the MMR copy
location and are active independently of whether
the Static Threshold bit is set. When the MMR is
read, then bits 22 and 23 are interpreted as follows:
bit 23
0
bit 22
0
0
1
1
0
1
1
condition
No overflow has occured
One or more positive overflows
have occured
One or more negative overflows
have occured
Both postive and negative
overflows have occured
Detailed block diagram of the Backend Post-processing Unit
Access to registers
The MMR and OUC are accessed, through the
memory interface, only via their associated buffers
(MMB and OUB respectively) and are not accessible directly. In order to load the MMR with a value,
the host must first write the value to the MMB and
then transfer the data from the MMB to the MMR
by performing a WRITE to the copy MMR location,
0B416. To read the MMR the host must first perform
a READ cycle from location 0B416 (which transfers
the contents of the MMR into the MMB) and then
read the MMB. The OUB is accessed in the same
way except that the dummy writes and reads are
done to and from location 0BC16.
Copies from MMR to MMB and OUC to OUB
(reads) can be performed at any time giving a
snapshot of the contents of the MMR and OUC
respectively. Copies from MMB to MMR and OUB
to OUC (writes) can also be performed at any time
allowing the threshold and counter to be updated
dynamically.
5.3 Data transformation unit
The data transformation unit consists of a prescalar, an under/over select detector, a look up table
and a byte selector. It can be used in isolation to
perform abitrary data mappings, or in conjunction
with the data normaliser to implement sophisticated
dynamic range compression functions.
Prescalar
This allows an 8-bit field anywhere within the 22-bit
X bus to be selected as the address to the LUT. This
is performed by right shifting the X bus so that the
required 8 bits are at the least significant end. The
8/26
amount of right shift is programmed in BCR2[4-0]
and can have a value from 0 to 16.
Over/under select detector
With PosLUTAddr (SCR[6]) set to zero, this unit
monitors whether the amount of right shift performed by the prescalar is sufficient to include all
significant bits in, and maintain the sign of, the
selected 8 bit field (i.e. an over or under select is
generated if the most significant bit of the selected
8 bit field differs from any subsequent bit right up to
and including the most significant bit of the right
shifted X bus). This will be an overselect if the X
bus is positive (Bit 21 = 0), and an underselect if
the X bus is negative (Bit 21 = 1). In other words
the LUT address is always deemed to be signed
with an address range of -128 to 127.
If however the control bit PosLUTAddr (SCR[6]) is
set to one, the unit monitors whether the amount of
right shift performed by the prescaler is sufficient to
include all significant bits in the selected 8 bit field
AND that all unselected bits are zero (i.e. an over
or under select is generated if the first selected bit
(bit 9) is not zero OR differs from any subsequent
bit right up to and including the most significant bit
of the right shifted X bus). This will be an overselect
if the Xbus is positive and an underselect WHENEVER the Xbus is negative. Thus, in this mode, the
address range of the LUT is 0 to 255.
Prescalar under/over selects and X bus positive/negative overflows are passed to the LUT
along with the selected 8 bit address field.
Look up table (LUT) and byte select
The LUT consists of 64 words, 32 bits wide plus two
special 32 bit locations called the upper and lower
saturation registers (USR and LSR respectively).
Thus the LUT is actually 66 words by 32 bits. The
32 bit output of the LUT is called the Y bus.
The most significant 6 bits of the 8 bit address field
are used to address one of 64 words in the LUT.
The least significant pair of bits in the 8 bit field are
used to control a byte select on the output. Thus in
addition to operating as a 64+2 word look up table
of 32 bit words, it can be used as an 8 bit, 256+2
byte LUT providing 8bit — 8bit transformations.
Positive overflows on the X bus, and over selects
in the prescalar cause the LUT to access the USR
overriding the address given by the prescalar. Likewise negative overflows and under selects cause
the LUT to access the LSR. Any sort of overflow on
the X bus or prescalar will cause the byte select
control to be overridden and the most significant
byte (byte 3) of the appropriate Saturation Register
will appear on the byte wide output of the data
transformation unit.
IMSA110
If there are simultaneous overflows on the X bus
and in the prescalar then the overflow from the X
bus takes priority.
The USR and LSR can thus be used to model the
saturating behaviour of analogue circuits instead of
the usual ‘wrap around’ encountered in digital systems. Alternatively the USR and LSR could signal
error conditions within the backend directly on the
output pins via one of the output multiplexers.
The LUT is loaded via the memory interface. The
addressing for the LUT corresponds to the 8 bit
field, assuming that the byte selector is being used.
In order to access the look up table, USR and LSR
from the microprocessor interface, the LUT Access control bit ACR[1] must be set to zero. This
will force the Y bus to zero and the normaliser to be
controlled by BCR3[7-3] regardless of the setting of
the dynamic normalisation bit, BCR3[2]. The LUT,
USR and LSR can then be loaded with any arbitrary
value via the microprocessor interface. Setting the
LUT access control bit to one will then allow the LUT
to be used in the data transformation unit.
5.4 Data normaliser
This unit consists of a shifter capable of right shifts
of up to 14 bits and left shifts up to 2 bits, followed
by a zero data unit and an adder. The shifter is
controllable from one of two 5 bit sources : control
bits BCR3[7-3] or bits 26 to 22 of the Y bus. The
cont rol bit Enable Dynamic Normalisation
(BCR3[2]) determines which source is in control of
the normaliser. If this bit is set to zero the normaliser
is controlled by BCR3[7-3]. The five bit field is a
twos complement number between 14 and -2. This
indicates the amount of right shift (negative meaning left shift). Any value outside this range causes
the output of the shifter to be forced to zero. The
output of the shifter, with any rounding generated
by the shifter, goes into the output adder.
5.5 Output adder
This is a 22 bit adder with one of its inputs coming
from the data normaliser. The other input is either
bits 21 to 0 of the Y bus from the data transformation
unit, or set to zero under the control of BCR3[1].
Note that any overflow occuring due to left shifting
in the normaliser or the subsequent addition in the
output adder is not detected by the IMSA110.
5.6 Output multiplexers
These two multiplexers allow the currently selected
byte from the LUT to be optionally selected to drive
either the most significant byte and/or the least
significant byte of the Cascade Output pins. This is
controlled by the state of BCR2[5] and BCR2[6].
Enabling either of these multiplexers overrides the
state of the Cascade Output pins only on the relavent 8 pins. The remaining pins will continue to
represent the output of the output adder.
6. BACKEND POST-PROCESSOR — Modes of
Operation
The backend post-processing unit is capable of
performing many functions including data scaling,
transformation, dynamic range compression and
histogram equalisation.
6.1 Default mode (after Reset)
At power up or after reset the state of the backend
post-processor is such that data from the MAC
array and the cascade input are added and pass
straight through the datapath unaffected.
The default mode for the statistics monitor is min
register although the values in the OUB, OUC,
MMR and MMB will be undefined. Likewise the
contents of the LUT, USR and LSR will be undefined, the LUT Access control bit will be zero
forcing the Y bus to zero and allowing the microprocessor interface to access the LUT, USR and
LSR.
Note that the cascade output pins and the PSR
output pins are tristated.
6.2 Cascade adder / MAC data scalar
These units allow the cascading of IMS A110s
where the output of the MAC array may be scaled
before it is added to the cascade input data. The
shifter can also be used for combining devices to
obtain extended precision in input data, coefficient
word length or both.
The ability to zero the cascade input provides a
simple means of controlling the number of ‘active’
devices cascaded as well as a means of debugging
large systems.
6.3 Rectification
Rectification, the removal of negative results, is
needed in several image processing functions.
For example, edge detection using a Sobel operator usually requires full wave rectification due to the
different signs obtained at differing edge transitions. Edge detection using a Laplacian operator
produces a change of sign at an edge. In this case,
removing negative numbers using half wave rectification can produce better results as full wave
rectification can lead to some blurring of the edge
transition.
9/26
IMSA110
6.4 Static scaling
This can be performed using one of two units: the
MAC array output shifter (as above), and the data
normaliser. In the second case the data undergoes
a simple scaling operation (with rounding) within
the normaliser. The normaliser can be used to scale
(multiply) the data by the factors 0, 1/16384,
1/8192, 1/4096 ..., 1/2, 1, 2, 4. By controlling the
normaliser from the control bits BCR3[7-3], this
provides a means for simple scaling of the data
before it is output. Setting BCR3[1] and BCR2[6,7]
to zero ensures that the data transformation unit
takes no part in the operation and the output of the
normaliser is passed unchanged to the output pins.
6.5 Dynamic scaling
In this mode the scaling is controlled by the data
itself. i.e. the scalar is controlled from the LUT
(Ybus bits 26-22) by setting BCR3[2] to one, the
Ybus input to the output adder being set to zero
either by setting BCR3[1] to zero or programming
the LUT accordingly. This mode can provide a
discontinuous non-linear transformation.
6.6 Simple transformation
This mode allows the user to apply arbitrary transformations to the data before it is output. Here the
LUT is treated as 256 by 8, addressed as either
-128 to 127 if PosLUTAddr is set to zero or 0 to 255
if PosLUTAddr is set to one. The 8 bit field selected
by the LUT prescalar is used to address a byte in
the LUT which is passed directly to the output pins
via one of the output multiplexers. Ybus control of
the data normaliser is disabled, BCR3[7-3] are set
out of range so as to zero the normaliser output and
the Ybus input to the output adder is set to zero by
BCR3[1]. One (or both) of the output multiplexers
are enabled and so the addressed byte from the
LUT passes straight to the cascade output pads.
Only the most significant byte of the USR and LSR
are applicable in this mode as overflows override
the byte select control and force it to select the most
significant byte.
6.7 Dynamic normalisation
In this mode the normaliser and transformation
units in the output conditioner are used together to
perform sophisticated non-linear dynamic range
compression and transformations. As in the simple
transformation case the prescalar selects an 8 bit
field anywhere within the X bus. The most significant 6 bits, and overflows, are fed as an address to
the LUT. In this case the look up table is treated as
64+2 by 32. Bits 26 to 22 of the Y bus are used to
control the normaliser block so that the input to the
normaliser is dynamically scaled. The output of the
normaliser is then added in the output adder to the
least significant 22 bits of the Y bus (Note that only
28 bits of the 32 bit Y bus are actually used).
Thus the data is scaled, rounded, and then an offset
is added to the scaled result. Each operation can
be viewed as
output = input × scale + offset
Where scale and offset are both programmable
functions of input. One way to view this operation
is to consider that the original data range is divided
into 64 equal sized levels and in each level a
different scale and offset is applied. The scale and
offset stored in the USR and LSR would be chosen
to give the desired behaviour under overflow conditions.
Note that in the case of cascade adder overflows,
the data on the X bus is invalid, so the scale here
would usually be set out of range so as to zero the
normaliser output. The offsets in the USR and LSR
would then provide the cascade output directly.
Note also that if the 5 bit scale field in the LUT is
programmed so that the normaliser always zeros
the data, then the output will correspond to the 22
bit offset field in the LUT. This can be viewed as a
coarse transformation with wide dynamic range
which is useful for applications such as image
contour emphasis and equalisation.
Figure 5 : Bit Format of Data Stored in LUT, USR and LSR
24 23
BYTE 3
scale if
BCR3 [2] = 1
10/26
16 15
BYTE 2
offset if BCR3 [0] = 1
8 7
BYTE 1
0
BYTE 0
A110-06.EPS
31
IMSA110
7. GLOSSARY
This section defines the meaning of terms used
elsewhere in this data sheet.
Arithmetic Shift
For a right shift, the most significant bit is always
copied into the most significant end of the result.
For example shifting right by 2:
→
→
01000101
11000101
00010001
11110001
For a left shift, the least significant bit will become
zero.
Note that left shifting can cause overflows and
these are not detected in the MAC output scalar or
the data normaliser.
Rounding
All rounding done within the IMS A110 is equivalent
to truncating after adding 1/2 LSB. (Rounding is
always applied in the positive direction). For example for 8 bit twos complement numbers undergoing
a two bit right shift:
00000011
00000010
11111110
00000001
11111101
→
→
→
→
→
00000000 + 1 = 00000001 (rounded up)
00000000 + 1 = 00000001 (rounded up)
11111111 + 1 = 00000000 (rounded up)
00000000
(no rounding)
11111111
(no rounding)
Left shifts do not generate rounding.
Transversal Filter
A transversal filter is a calculation consisting of the
sum of products of successive points of input data.
For input data xi, xi+1, ..., and a set of coefficients,
c6,c5, ..., the result, Y is:
6
Y=∑ci × x6−i
i=0
Two’s Complement
Two’s complement numbers allow both positive
and negative numbers. For example in 8 bit numbers the most positive number is 127, the most
negative is -128:
two’s complement
10000000
10000001
11111111
00000000
00000001
01111111
decimal
-128
-127
-1
0
1
127
Rectification
Rectification is a method of removing negative
numbers. There are two methods: Full wave and
Half wave. In either case all positive numbers and
zero are unaffected. In Full wave rectification, any
negative numbers are negated (i.e. multiplied by 1)
so that they become positive. In Half wave rectification, all negative numbers are replaced by zero.
Dynamic Range Compression
When Dynamic is used in this context, it is to
indicate a change of behaviour for each data point.
For example, a dynamic shift is one where the size
of the shift may change on each successive clock
cycle. Dynamic range compression is range compression making use of an offset and shift, which
can change depending on each data point. This
allows the essential non-linear transformations required in image processing to be implemented on
the IMS A110.
Bit Fields
Bits, words and addresses in this data sheet are
little-endian; The lowest order byte of a multiple
byte word is referred to as byte 0, and is addressed
in the same way. Similarly, the least significant bit
of any bit field is that with the lowest bit number. For
example, ‘bits 26-22’ refers to a 5 bit field where bit
22 is treated as the least significant, and bit 26 as
the most significant.
Latency
Within the IMSA110 the latency is the number of
clock cycles from an input to its corresponding
output. For instance, with the programmable shift
registers bypassed by setting SCR[1] to 1, the
latency from PSRin to PSRout will be 2 as shown
in Figure 6.
11/26
IMSA110
Figure 6
1
2
3
CLK
A110-07.EPS
PSRIN
PSROUT
PSRIN latched
PIN DESIGNATIONS
System services
Pin
In/out
VCC, GND
Function
Power supply and return
CLK
in
Input clock
RESET
in
System reset
Synchronous input/output
Pin
In/out
Function
PSRin[7-0]
in
Programmable shift register
input
out
Programmable shift register
output
PSRout[7-0]
Cin[21-0]
in
Cascade input port
Cout[21-0]
out
Cascade output port
Asynchronous input/output
Pin
In/out
Function
E1, E2
in
Memory interface enable
signals
W
in
Memory interface write
enable
ADR[8-0]
in
Memory interface adress bus
D[7-0]
in/out
Memory interface data bus
Note : Signal names are shown with an overbar if they are active
low, otherwise they are active high.
8.1 System services
System services include all the necessary logic to
start up and maintain the IMS A110.
Power
Power is supplied to the device via the VCC and
GND pins. Several of each are provided to mini12/26
mise inductance within the package. All supply pins
must be connected. The supply must be decoupled
close to the chip by at least one 100nF low inductance (e.g. ceramic) capacitor between VCC and
GND.
CLK
The clock signal CLK controls the timing of input
and the output on the four dedicated interfaces, and
controls the progress of data through the shift registers, multiply-accumulate array and post-processing unit. The A110 is fully static so the clock can
be slowed down or stopped in either state without
corrupting data.
RESET
If this pin is taken low for at least 2 clock cycles, the
control logic within the IMS A110 will be reset and
all of the control and configuration registers will be
initialised to their default values. All other register,
memory locations, datapath registers and shift registers will not be reset by this signal.
A reset is initiated automatically when power is first
applied to the device. This reset will be completed
once four cycles of CLK have occured after VCC is
valid.
8.2 Synchronous services
PSRin[7-0]
This 8-bit wide bus supplies input data to the device. The input data enters the first of the three shift
registers in the chain. The timing of this input is
controlled by the CLK signal. The data on the
PSRin port is sampled on the rising edge of the
clock. In a cascade arrangement, this bus will be
connected to the PSRout port of the previous device. In such an arrangement the PSRin port on the
first device will be the input to the overall cascaded
system.
IMSA110
PSRout[7-0]
This bus outputs the data from the last programmable shift register in the chain. The data on this bus
is synchronously clocked by the rising edge of CLK.
In a cascade arrangement this port will be connected to the PSRin port of the next device. At
power up, or after a reset, the PSRout pins are
tristated. They are enabled by SCR[5].
the Write Enable and the address inputs are ignored and the microprocessor interface Data signals are high impedance. When both Enable signals are low a read or write access is made to
registers or the RAMs within the IMSA110. Access
to the microprocessor interface can occur asynchronously to the synchronous pins (PSRin,
PSRout, Cin, Cout) of the device.
Cin[21-0]
The Cascade Input port allows IMSA110s to be
cascaded. It also can be used for combining an
external signal (e.g. a reference image or an offset)
with the processed result. In a cascade arrangement, this bus will be connected to the Cascade
Output of the previous device. The data on the Cin
bus is sampled on the rising edge of CLK.
W
Write Enable indicates whether the access to the
IMS A110 memory interface is to be a read or a
write. If W is low a write access is indicated.
Cout[21-0]
This bus outputs the processed result from the
IMSA110 and can also be used for cascading. The
22-bit result is synchronously clocked by the rising
edge of CLK. In a typical cascaded system this bus
will be connected to the Cascade Input port of the
next device. On the last device in the cascade, this
bus will be the output of the overall system. At
power up, or after a reset, the Cout pins are tristated. They are enabled by SCR[4].
8.3 Asynchronous input/output
E1, E2
If both of these signals are low, then the microprocessor interface is enabled. The operation of these
enable signals is very similar to those found on
static RAMs. When either of these signals are high
ADR[8-0]
The nine bit binary value applied to the address
inputs of the IMSA110 indicates which register or
RAM location within the device is to be accessed.
D[7-0]
During a write to the microprocessor interface an
8-bit word is applied to the Data pins which is
written to the appropriate location. During a read
cycle the contents of the location accessed are
placed on the Data pins. When either of the Enables are high the Data pins are high impedance.
9 REGISTER DESCRIPTION
Memory map
Within the IMSA110 addresses are fully decoded.
Reading from locations not defined in the memory
map will produce zero data. Data written to such
locations is ignored. This allows the part to be fully
programmed using a ROM with an address incremeter. In this case, for future compatibility, zero
should be written to all undefined locations.
13/26
IMSA110
Register
Address decimal
Address hex
Function
CR0a
0—6
000—006
Coefficient Registers Bank 0a
CR0b
16—22
010—016
Coefficient Registers Bank 0b
CR0c
32—38
020—026
Coefficient Registers Bank 0c
CR1a
64—70
040—046
Coefficient Registers Bank 1a
CR1b
80—86
050—056
Coefficient Registers Bank 1b
CR1c
96—102
060—066
Coefficient Registers Bank 1c
PCRA
128—129
080—081
PSRA Control Register
PCRB
130—131
082—083
PSRB Control Register
PCRC
132—133
084—085
PSRC Control Register
SCR
144
090
Static Control Register
ACR
146
092
Active Control Register
BCR
160—163
0A0—0A3
Backend Configuration Register
MMB
176—178
0B0—0B2
Maximum/Minimum Buffer
CMM
180
0B4
OUB
184—186
0B8—0BA
COU
188
0BC
Copy OUC
TCR
208
0D0
Test Control Register
USR
248—251
0F8—0FB
LSR
252—255
0FC—0FF
Lower Saturation Register
LUT
256-511
100—1FF
Look up Table
9.2 Registers
CR0a
Coefficient registers bank 0a
These seven 8-bit locations contain coefficients
which can be used by the third, of the three, 7-stage
mac arrays. CR0a(0) (address #000) corresponds
to the coefficient register of this mac array nearest
to its output. Similarly CR0a(6) (address #006)
corresponds to the coefficient register of this mac
nearest to its input. These Coefficient registers can
be written to provided that the other register bank
is in use. Whether the coefficient written is signed
or unsigned is determined by the ‘Unsigned Coefficient’ bit SCR[3]. Once a value is written to a
coefficient register, its value can be read back from
14/26
Copy MMR
Overshoot/Undershoot Buffer
Upper Saturation Register
an internal duplicate register. These registers will
be used by the mac array, when ACR[0], ‘Current
Bank’ is set to zero. Writing to these Coefficient
Registers while in use will result in an undefined
operation of the mac array.
CR0b
Coefficient registers bank 0b
These seven 8-bit locations contain coefficients
which can be used by the second, of the three,
7-stage mac arrays in the chain. CR0b(0) (address
#010) corresponds to the coefficient register of this
mac array nearest to its output. Similarly CR0b(6)
(address #016) corresponds to to the coefficient
register of this mac nearest to its input. Their behaviour is otherwise identical to CR0a.
IMSA110
Figure 7 : IMSA110 Memory Map
Address
(Hex)
Name
bit
7
6
5
4
3
2
1
0
Dynamic
normalisation
LUT to
output
adder
0
1FF
LUT
Look Up Table
100
0FC-0FF
LSR
Lower Saturation Register
0F8-0FB
USR
Upper Saturation Register
0D0
TCR
0BC
COU
Copy Over/UnderShoot Buffer
0B8-0BA
OUB
Over/UnderShoot Buffer
0B4
CMM
Copy Min/Max Buffer
0B0-0B2
MMB
Min/Max Buffer
0A3
BCR3
0A2
BCR2
0
LS
output
byte
MS
output
byte
0A1
BCR1
0
0
0
0A0
BCR0
Full
Wave
Half
Wave
092
ACR
0
0
0
0
0
0
Backend
LUT
Access
Current
Bank
090
SCR
0
PosLUT
Addr
PSR Out
Enable
Cascade
Enable
Unsigned
Coef
Load
Unsigned
Data
Bypass
PSRs
Cont
Swap
085
PCRC
0
0
0
0
0
0
0
0
0
0
0
084
PCRC
083
PCRB
Normaliser Control
Look Up Prescaler
0
0
0
Static
threshold
Greater
Than
Zero
Cascade
MAC Output Scaler
Shift Length (Upper Bits)
Shift Length (Lower Bits)
0
0
082
PCRB
081
PCRA
080
PCRA
Shift Length (Lower Bits)
066
...
060
CR1c
Bank 1 Coefficient Register
056
...
050
CR1b
Bank 1 Coefficient Register
046
...
040
CR1a
Bank 1 Coefficient Register
026
...
020
CR0c
Bank 0 Coefficient Register
016
...
010
CR0b
Bank 0 Coefficient Register
006
...
000
CR0a
Bank 0 Coefficient Register
Shift Length (Upper Bits)
Shift Length (Lower Bits)
0
0
Shift Length (Upper Bits)
15/26
IMSA110
CR0c
Coefficient registers bank 0c
These seven 8-bit locations contain coefficients
which can be used by the first, of the three, 7-stage
mac arrays in the chain. CR0c(0) (address #020)
corresponds to the coefficient register of this mac
array nearest to its output. Similarly CR0c(6) (address #026) corresponds to to the coefficient register of this mac nearest to its input. Their behaviour
is otherwise identical to CR0a.
CR1a
Coefficient registers bank 1a
These seven 8-bit locations contain coefficients
which can be used by the third, of the three, 7-stage
mac arrays in the chain. CR1a(0) (address #040)
corresponds to the coefficient register of this mac
array nearest to its output. Similarly CR1a(6) (address #046) corresponds to to the coefficient register of this mac nearest to its input. These registers
will be used provided that ACR[0], ‘Current Bank’ is
set to one, or continuous bank swap mode is in
operation (SCR[0] set to one).
CR1b
Coefficient registers bank 1b
These seven 8-bit locations contain coefficients
which can be used by the second, of the three,
7-stage mac arrays in the chain. CR1b(0) (address
#050) corresponds to the coefficient register of this
mac array nearest to its output. Similarly CR1b(6)
(address #056) corresponds to to the coefficient
register of this mac nearest to its input. Their behaviour is otherwise identical to CR1a.
CR1c
Coefficient registers bank 1c
These seven 8-bit locations contain coefficients
which can be used by the second, of the three,
7-stage mac arrays in the chain. CR1c(0) (address
#060) corresponds to the coefficient register of this
mac array nearest to its output. Similarly CR1c(6)
(address #066) corresponds to to the coefficient
register of this mac nearest to its input. Their behaviour is otherwise identical to CR1a.
PCRA
PSRA Control register
This is a 16-bit register, with least significant byte
at location #080, and is used to set up the length of
the last shift register in the chain. Programmed
lengths outside the range 0 to 1120 will cause
undefined behaviour of the shift register.
PCRB
PSRB Control register
This is a 16-bit register, with least significant byte
at location #082, and is used to set up the length of
the second shift register in the chain. Programmed
lengths outside the range 0 to 1120 will cause
undefined behaviour of the shift register.
16/26
PCRC
PSRC Control register
This is a 16-bit register, with least significant byte
at location #084, and is used to set up the length of
the first shift register in the chain. Programmed
lengths outside the range 0 to 1120 will cause
undefined behaviour of the shift register.
SCR
Static control register
The Static Control Register contains the control bits
which set up parts of the IMS A110 which are likely
to not need reconfiguration during processing. The
contents of this register are not affected by the IMS
A110 and can be read at any time. Modifying the
Static Control register during processing will result
in undefined behaviour. Normal operation will start
to occur between 0 and 3 clock cycles after the
completion of the write cycle.
ACR
Active control register
The Active Control Register contains status and
control bits which are likely to be accessed during
normal operation of the IMS A110.
BCR
Backend configuration register
The Backend Configuration Registers consist of
four byte-wide registers BCR0, BCR1, BCR2, and
BCR3 which are located at addresses #0A0, #0A1,
#0A2, and #0A3 respectively. These four registers
are used to control the backend post-processing
unit. None of the control bits in these registers can
be modified by the IMS A110. Modification of the
values in these registers during processing may
result in undefined behaviour. Normal operation will
start to occur between 0 and 3 clock cycles after the
completion of the write cycle.
MMB
Maximum/minimum buffer
These three locations hold a 24-bit wide word, with
the least significant byte at the lowest address, and
act as a buffer between the MMR and the microprocessor interface. All the transactions between
the MMR and the host processor must take place
through this register. When the MMR is not in use,
the value of this buffer is undefined.
CMM
Copy MMR
This location is used to enable the data transfer
between the MMB and MMR. A write to this location
causes the contents of MMB to be copied into the
MMR and bits 23 and 22 of the MMR (the cascade
adder overflow flags) to be set to zero. A read from
this location causes the reverse, i.e the contents of
the MMR are copied into the MMB. The value
written to this location is ignored, the value read
back is undefined.
IMSA110
OUB
Overshoot/undershoot buffer
These three memory locations hold a 22-bit word,
with the least significant byte at the lowest address,
and act as a buffer between the OUC and the
microprocessor interface. All the transactions between the OUC and the host processor must take
place through this register. When the OUC is not in
use, the value of this buffer is undefined.
COU
Copy OUC
This location in the memory is used to enable the
data transfer between the OUB and OUC. A write
to this location causes the contents of OUB to be
copied into the OUC. A read from this location
causes the reverse, i.e the contents of the OUC are
copied into the OUB. The value written to this
location is ignored, the value read back will be
undefined.
TCR
Test control register
This register is used for testing, and should be
loaded with zero for normal operation.
USR
Upper saturation register
This is a 32-bit value with the least significant byte
at the lowest address. Its contents are used to
replace the LUT output if positive overflow(s) occur
in the look up prescaler and / or in the cascade
adder. Accesses from the microprocessor interface
can only be made while ACR[1] is set to zero.
LSR
Lower saturation register
This is a 32-bit value with the least significant byte
at the lowest address. Its contents are used to
replace the LUT output if negative overflow(s) occur
in the look up prescaler and / or in the cascade
adder. Accesses from the microprocessor interface
can only be made while ACR[1] is set to zero.
LUT
Look up table
These locations are for the 256-byte look up table
which is used for data mapping and transformation
operations. From the microprocessor interface,
these locations are addressed in the same way as
that seen by the 8-bit output of look up prescaler.
When used in 32 bit mode, the locations are treated
in the same way as other 32 registers: Word 0 has
its most significant byte at #103, its least significant
byte at #100, Word 12 has its most significant byte
at #133, its least significant byte at #130. Accesses
from the microprocessor interface can only be
made while ACR[1] is set to zero.
10. REGISTERS — BIT ALLOCATION
This section describes the register details bit by bit.
Each section commences with the name of the
register with the bit number(s) followed by the default value, in the general format:
Name
REGISTER [MSB—LSB] Default : MSB...LSB
The least significant bit of a register is bit 0.
* in the tables indicates the default state of the
register bit(s).
10.1 PSR control registers (PCR)
PSRA control
PCRA[10-0]
Default: 0…
…0
These eleven least significant bits of the PCRA are
used to specify the length of the last Programmable
Shift Register (PSRA). The length of the shift register will be numerically equal to the binary value
loaded in these bits. The value loaded in must be
in the range of 0 to 1120 decimal. If a value outside
this range is written to these bits the behaviour of
the shift register will be undefined. After updating
this register, the behaviour of the delay is undefined
for 22 clock cycles. Hence changing the length from
1000 to 1001 delays, will result in correct output
only after 1023 cycles. This will also have to propagate through the backend before the cascade output values will be correct.
Reserved
PCRA[15-11]
Default: 00000
These 5 most significant bits of the PCRA are
reserved. The user should write zero to these locations to maintain compatibility with future products.
The value read from these locations will be zero.
17/26
IMSA110
PSRB control
PCRB[10-0]
Default: 0…
…0
These eleven least significant bits of the PCRB are
used to specify the length of the second Programmable Shift Register (PSRB). The length of the shift
register will be numerically equal to the binary value
loaded in these bits. The value loaded in must be
in the range of 0 to 1120 decimal. If a value outside
this range is written to these bits the behaviour of
the shift register will be undefined. After updating
this register will also have to propagate through
PSRA and the backend before the cascade output
values will be correct
Reserved
PCRB[15-11]
Default: 00000
These 5 most significant bits of the PCRB are
reserved. The user should write zero to these locations to maintain compatibility with future products.
The value read from these locations will be zero.
PSRC control
PCRC[10-0]
Default: 0…
…0
These eleven least significant bits of the PCRC are
used to specify the length of the first Programmable
Shift Register (PSRC). The length of the shift register will be numerically equal to the binary value
loaded in these bits. The value loaded in must be
in the range of 0 to 1120 decimal. If a value outside
this range is written to these bits the behaviour of
the shift register will be undefined. After updating
this register will also have to propagate through
PSRB, PSRA and the backend before the cascade
output values will be correct
Reserved
PCRC[15-11]
Default: 00000
These 5 most significant bits of the PCRC are
reserved. The user should write zero to these locations to maintain compatibility with future products.
The value read from these locations will be zero.
10.2 Static control register (SCR)
Reserved
SCR[7]
Default: 0
This location is reserved. The user should write
zero to this location to maintain compatibility with
future products. The value read from this location
will be zero.
Positive Look up
table address
SCR[6]
Default: 0
This bit affects the way in which the over/under
select detector checks the LUT address. It determines whether the address range of the LUT is
signed (-128 to 127) or positive (0 to 255). A one at
this location indicates a positive LUT address.
PSR out Enable
SCR[5]
Default: 0
A zero at this location will force the PSR Output pins
into the tristate mode.
18/26
Cascade Enable
SCR[4]
Default: 0
A zero at this location will force the Cascade Output
pins into the tristate mode.
Unsigned coefficient
load
SCR[3]
Default: 0
If this bit is set to one, the format of subsequently
loaded coefficients become unsigned, with coefficient value assuming a range between 0 and 255
decimal. An 8-bit coefficient with all its bits set to
one will represent +255 decimal. When this bit is
zero the format of subsequently loaded coefficients
will be twos complement and the corresponding
numerical value will have a range between -128
and +127. By changing this bit whilst coefficients
are being loaded, coefficients between -128 and
+255 can be used. The unsigned format on all
coefficients is suitable when IMS A110s are combined to obtain wider coefficients for extended precision.
SCR[3]
Coefficient type
0
Signed coefficients *
1
Unsigned coefficients
Unsigned data
SCR[2]
Default: 0
If this bit is set to one, the IMS A110 input data
format will become unsigned, with input data value
assuming a range between 0 and 255 decimal. An
8-bit value with all its bits set to one will represent
+255 decimal. When this bit is zero the input data
format will be twos complement and the corresponding numerical value will have a range between -128 and +127. Unlike SCR[3], this bit cannot
be used to dynamically alter the data format. The
unsigned format is suitable when IMS A110s are
combined to obtain wider input data for extended
precision.
SCR[2]
Data type
0
Signed data *
1
Unsigned data
Bypass shift registers SCR[1]
Default: 0
This bit is used to program the path between the
PSRin and PSRout ports. A zero at this location will
cause the output from the last programmable shift
register to be sent to PSRout port. Writing a one to
this bit will cause the three programmable shift
registers to be bypassed, and the data entering the
port PSRin to be fed directly, via a delay of 2 clock
cycles, to the port PSRout. This bit allows full programmability of a cascade arrangement so that the
same hardware can be operated in a variety of
ways.
IMSA110
Continous bank swap SCR[0]
Default: 0
The continuous bank Swap bit selects whether the
the two banks of coefficient registers are used
alternately after each data input or if this is controlled solely by the state of the ‘Current Bank’ bit in the
Active Control Register ACR[0].
SCR[0]
Swap mode
0
Swap on asserting ACR[0] *
1
Swap after end of each input cycle
10.3 Active control register (ACR)
Reserved
ACR[7-2]
Default: 00000
These 6 most significant bits of the ACR are reserved. The user should write zero to these locations to maintain compatibility with future products.
The value read from these locations will be zero.
Enable look up table
ACR[1]
Default: 0
Writing a zero into this control bit allows the memory
interface to access the Look up table; the output to
the data transformation unit will be zero. The normaliser will be controlled by BCR3[7-3], regardless
of the state of BCR3[2]. Writing a one to ACR[1]
allows the IMS A110 to use the Look up Table. After
changing this bit, 2 clock cycles must occur before
the Look up Table can be accessed.
ACR[1]
LUT mode
0
Memory interface access *
1
Data transformation unit
Current bank
ACR[0]
Default: 0
When the ‘Continuous Bank Swap’ bit is set to zero,
writing a zero into this control bit instructs the IMS
A110 to use the set of coefficient registers at addresses 0 to #X26. Setting a one to this bit instructs
the IMS A110 to use the set of coefficient registers
at addresses #40 to #X66. If the ‘Continuous Bank
Swap’ bit is set to one, then this bit only indicates
the bank selected for the first cycle of the continuous swap mode. Writing to this bit whilst in continuous bank swap mode (SCR[0]=1) will result in
undefined behaviour of the mac array.
full-wave rectified (absolute value operation) before it is fed to the remainder of the backend. This
bit will override the function of the BCR0[6].
Enable half-wave
rectification
Coefficient bank
0
Use coefficient registers at 0 to #X26 *
1
Use coefficient registers at #40 to #X66
10.4 Backend control register 0 (BCR0)
Enable full-wave
rectification
BCR0[7]
Default: 0
If this bit is set the output of the cascade adder is
Default: 0
Writing a one in this bit will cause the negative
values from the cascade adder to be replaced with
zero. Note that writing a one into BCR0[7] will
override the function of this control bit.
BCD0[7-6]
Rectifier mode
00
Straight through *
01
Half wave rectification
10
Full wave rectification
11
Full wave rectification
Mac array output
scaler
BCR0[5-1]
Default: 00000
The contents of these five bits control the amount
of right or left shift applied to the data at the output
of the mac array. This field is interpreted as a two’s
complement number. A positive number represents a right shift (divide). Any shift in the range -8
(11000) to +8 (01000) is legal. Values outside this
range will result in undefined behaviour of the mac
output scaler.
Zero cascade input
BCR0[0]
Default: 0
This bit controls the Cascade Input Multiplexer.
Writing a one to this bit will cause a zero, instead of
the cascade input data, to be fed to the cascade
adder.
BCR[0]
Cascade input mode
0
Cascade data *
1
Zero
10.5 Backend control register 1 (BCR1)
Reserved
BCR1[7-2]
Default: 00000
These locations are reserved. The user should
write zero to these locations to maintain compatibility with future products. The values read from
these locations will be zero.
Static threshold
ACR[0]
BCR0[6]
BCR1[1]
Default: 0
If this bit is set to one, the signals from the comparator will be used to increment the Over / Undershoot Counter only. If this bit is zero, the signals
from the comparator will be used to latch the output
of the Cascade Adder into the Maximum / Minimum
Register (MMR), and to increment the counter. In
this case the counter will have been incremented
by the number of times that the threshold has been
updated.
19/26
IMSA110
Enable greater than
BCR1[0]
Default: 0
This control bit determines whether the comparator
in the statistics monitor behaves as a ‘greater than’,
or as a ‘less than’ comparator. The signal from this
comparator is used to drive the Over / Undershoot
Counter and the Max / Min Register. A one at this
location selects ‘greater than’.
BCR1[1-0]
Statistics monitor mode
00
Min. register *
01
Max. register
10
Undershoot counter
11
Overshoot counter
10.7 Backend control register 3 (BCR3)
Normalizer control
10.6 Backend control register 2 (BCR2)
Reserved
BCR2[7]
Default: 0
This location is reserved. The user should write
zero to this location to maintain compatibility with
future products. The value read from this location
will be zero.
Pass LUT data to
least significant
output
BCR2[6]
Default: 0
This bit controls the output multiplexer. If this bit is
set to one, the selected byte from the LUT is output
on the least significant byte (bits 7 to 0) of the
Cascade Output pins.
Pass LUT data to most
significant output
BCR2[5]
Default: 0
This bit controls the output multiplexer. If this bit is
set to one, the selected byte from the LUT is output
on the most significant byte (bits 21 to 14) of the
Cascade Output pins.
Look up prescaler
BCR2[4-0]
Default: 00000
The contents of these five bits control the amount
20/26
of (arithmetic) right shift applied to the data, by the
Look up Prescaler. Writing a numerical value between 0 and 16 (binary 10000) into these bits, will
cause the data to be right-shifted by a corresponding number of places. For example, if the bit pattern
00101 is written to these five bit positions, a right
shift of 5 places will occur. Writing any value outside
the range (0 to 16) will result in undefined behaviour
of the look up Prescaler.
BCR3[7-3]
Default: 00000
These five bits control the number of places, that
the normaliser shifts the data to the right or to the
left. This field is interpreted as a twos complement
number. A positive number is taken to be a right
shift. Any shift in the range -2 (11110) to +14 (01110)
is legal. Any other value will cause the number zero
to be output from the normaliser.
Enable dynamic
normalization
BCR3[2]
Default: 0
If this bit is set to one, the normaliser will be controlled by bits 26 to 22 from the output of the look
up table, instead of BCR3[7-3].
Feed LUT data to
output adder
BCR3[1]
Default: 0
One of the inputs of the Output Adder can be either
supplied by the Look up Table or forced to zero.
Setting this control bit to zero selects zero. Setting
this control bit to one selects bits 21 to 0 of the Look
up Table.
Reserved
BCR3[0]
Default: 0
This location is reserved. The user should write
zero to this location to maintain compatibility with
future products. The value read from this location
will be zero.
IMSA110
11. ELECTRICAL SPECIFICATION
11.1 DC electrical characteristics
ABSOLUTE MAXIMUM RATINGS
Symbol
VCC
VI, VO
TA
Tstg
PDmax
Parameter
DC supply voltage
Voltage on any other pin
Temperature under bias
Storage temperature
Power dissipation
Min.
0
-1.0
-40
-65
Typ.
Max.
7.0
VCC+0.5
85
150
2.0
Units
V
V
°C
°C
W
Notes (1,2)
3
3
Notes : 1. All voltages are with respect to GND.
2. This is a stress rating only and functional operation of the device at these or any other conditions above those indicated in the
operational sections of this specification is not implied. Stresses greater than those listed may cause permanent damage to the
device. Exposure to absolute maximum rating conditions for extended periods may affect reliability.
3. This device contains circuitry to protect the inputs against damage caused by high static voltages or electrical fields. However,
it is advised that normal precautions be taken to avoid application of any voltage higher than the absolute maximum rated
voltages to this high impedence circuit. Unused inputs should be tied to an appropriate logic level such as VCC or GND.
DC OPERATING CONDITIONS
Symbol
VCC
VIH
VIL
TA
Parameter
Supply Voltage
Input Logic ‘1’ Voltage CLK
Input Logic ‘1’ Voltage other pins
Input Logic ‘0’ Voltage CLK
Input Logic ‘0’ Voltage other pins
Ambient Operating Temperature
Min.
4.5
4.0
2.0
-0.5
-0.5
0
Typ.
5.0
Max.
5.5
VCC+0.5
VCC+0.5
0.5
0.8
70
Units
V
V
V
V
V
°C
Notes (1)
2
2
2
2
3
Notes : 1. All voltages are with respect to GND.
2. Input signal transients, up to 10ns wide, are permitted in the voltage ranges (GND - 0.5V) to (GND - 1.0V)
and VCC + 0.5V to VCC + 1.0V.
3. 400 linear ft/min transverse air flow.
DC CHARACTERISTICS
Symbol
VOH
VOL
IIN
IOZ
IDD
Notes : 1.
2.
3.
4.
5.
Parameter
Output Logic ‘1’ Voltage
Output Logic ‘0’ Voltage
Input leakage current(any input current)
Min.
2.4
0
Typ.
Off state output leakage current
Average power supply current
Max.
VCC
0.4
± 10
Units
V
V
µA
Notes (1,2)
4
5
3
± 10
350
µA
mA
3
Max.
Units
pF
pF
Notes
1,2
1,2
All voltages are with respect to GND.
Parameters measured over full voltage and temperature operating range.
VCC = VCC(max), GND ≤ VIN ≤ VCC
IOut ≤ -4.4 mA
IOut ≤ 4.4 mA
CAPACITANCE
Pin
Min.
CLK
All other pins
Typ.
12
5
Notes : 1. This parameter is supplied for engineering guidance and is not guaranteed.
2. TA= 25°C , F= 1 MHz.
21/26
IMSA110
11.2 Thermal Characteristics
PIN GRID ARRAY THERMAL CHARACTERISTICS
Symbol
θ JA
Parameter
Junction to ambient thermal resistance
Min
Nom
Max
35
Units
°C/W
Notes
1,2
Notes : 1. Measured at 400 linear ft/min transverse air flow.
2. This parameter is sampled and not 100% tested.
11.3 AC timing characteristics
AC test conditions
OUTPUT LOADS (except output turn-off tests) : 30pF for all outputs.
Figure 8 : Output Load (output turn-off tests)
DUT pin
I sink
V REF
I source
= 1mA
= 1.5V
= 1mA
A110-08.EPS
30pF
TIMING REFERENCE LEVELS
Pin
Reference levels
INPUTS
1
CLK
0.5V, 4.0V
OUTPUTS
0.4V, 2.4V
OUTPUTS
±100mV change from previous steady output voltage
Notes : 1.
2.
3.
4.
Notes
0.8V, 2.0V
2,3
4
Except CLK.
Output continously driven.
Timings are tested using VOL=0.8V and with a suitable allowance for the time taken for the output to fall from 0.8V to 0.4V.
Output turn-off tests.
11.4 Timing diagrams
CLOCK REQUIREMENTS
Symbol
Parameter
Min
Typ.
Max
Units
Notes
2
tCHCL
Clock Pulse High Width
20
ns
tCLCH
Clock Pulse Low Width
20
ns
2
tCHCH
Clock Period
50
ns
2
tR
Clock rise time
0
50
ns
1
tF
Clock fall time
0
50
ns
1
Notes : 1. Clock input transitions should be monotonic between the input thresholds of 0.5 V and 4.0 V.
2. For Rev.A parts tCHCL, tCLCH and tCHCH have maximum values of 50 000ns, 50 000ns and 100 000ns respectively.
(A minimum clock frequency of 10kHz.)
22/26
IMSA110
Figure 9
t CHCL
tF
tR
4.0V
CLK
0.5V
A110-09.EPS
t CLCH
t CHCH
MICROPROCESSOR INTERFACE READ CYCLE
Symbol
Parameter
Min
Max
Units
tAVEL
Address setup
0
ns
tEHAX
Address hold
0
ns
tWHEL
Read Command Setup
0
ns
tEHWX
Read Command Hold
0
ns
tELQX
Output turn-on
0
ns
tELQV
Read data access
tEHQX
Read data hold
tEHQZ
Output turn off
100
ns
25
ns
0
Notes
ns
Figure 10
E1
E2
t AVEL
t EHAX
ADDRESS
t WHEL
t EHWX
W
t ELQV
t EHQX
t ELQX
A110-10.EPS
DATA
t EHQZ
23/26
IMSA110
MICROPROCESSOR INTERFACE WRITE CYCLE
Symbol
Parameter
tELEH
Enable Width Low
tAVEL
Min
Max
Units
100
ns
Address setup
0
ns
tEHAX
Address hold
0
ns
tWLEL
Write Command Setup
0
ns
tEHWX
Write Command Hold
0
ns
tDVEH
Write data Set up
50
ns
tEHDX
Write data hold
0
ns
Notes
Figure 11
E1
t ELEH
E2
t AVEL
t EHAX
ADDRESS
t WHEL
t EHWX
W
DATA
24/26
t EHDX
A110-11.EPS
t DVEH
IMSA110
SYNCHRONOUS INPUT AND OUTPUT
Symbol
Parameter
Min
Max
Units
40
ns
tCHQV
CLK high to Output Valid
tCHQX
Output hold time after CLK
tDVCH
Input setup time to CLK high
8
ns
tCHDX
Input hold time to CLK high
0
ns
2
Notes
ns
Figure 12
INPUT
t DVCH
t CHDX
CLK
t CHQX
A110-12.EPS
t CHQV
OUTPUT
25/26
IMSA110
PACKAGE MECHANICAL DATA
100 PINS - GRID ARRAY PACKAGE
M
index
E
10
9
8
7
6
5
4
3
2
1
A
F
B
C
D
A B1
E
K
F
G
H
J
K
G
L
Millimetres
PMPGA100.EPS
A
DIM
L
K
D
Inches
Notes
Nom
Tol
Nom
Tol
A
26.924
± 0.254
1.060
± 0.010
B1
17.019
± 0.127
0.670
± 0.005
B2
18.796
± 0.127
0.740
± 0.005
C
2.456
± 0.278
0.097
± 0.011
D
4.572
± 0.127
0.180
± 0.005
E
3.302
± 0.127
0.130
± 0.005
F
0.457
± 0.051
0.018
± 0.002
Pin diameter
G
1.143
± 0.127
0.045
± 0.005
Flange diameter
K
22.860
± 0.127
0.900
± 0.005
L
2.540
± 0.127
0.100
± 0.005
M
0.508
0.020
Chamfer
Information furnished is believed to be accurate and reliable. However, SGS-THOMSON Microelectronics assumes no responsibility
for the consequences of use of such information nor for any infringement of patents or other rights of third parties which may result
from its use. No licence is granted by implication or otherwise under any patent or patent rights of SGS-THOMSON Microelectronics.
Specifications mentioned in this publication are subject to change without notice. This publication supersedes and replaces all
information previously supplied. SGS-THOMSON Microelectronics products are not authorized for use as critical components in life
support devices or systems without express written approval of SGS-THOMSON Microelectronics.
© 1994 SGS-THOMSON Microelectronics - All Rights Reserved
Purchase of I2C Components of SGS-THOMSON Microelectronics, conveys a license under the Philips
I2C Patent. Rights to use these components in a I2C system, is granted provided that the system conforms to
the I2C Standard Specifications as defined by Philips.
SGS-THOMSON Microelectronics GROUP OF COMPANIES
Australia - Brazil - China - France - Germany - Hong Kong - Italy - Japan - Korea - Malaysia - Malta - Morocco
The Netherlands - Singapore - Spain - Sweden - Switzerland - Taiwan - Thailand - United Kingdom - U.S.A.
26/26
PGA100.TBL