ARCH AEC60-24S

VER : A_3
update : 98.06.09
AC-DC Medical
AEC60 SERIES
60 Watts
KEY FEATURES
„ Switching Power Module for PCB Mountable
„ Universal Input: 85-265 VAC
„ Single Output
„ 5 VDC to 48 VDC Output
„ -40OC Starting
„ 4000 VAC Input to Output Isolation
„ CE, UL, Approval
„ 2-Years Product Warranty
ELECTRICAL SPECIFICATIONS
Model No.
AEC60-5S
Max Output Wattage (W)
Voltage
50W
Output
Isolation
2 A max. (115 VAC) / 1 A max. (230 VAC)
30 A max. (115 VAC) / 50 A max. (230 VAC)
Leakage Current
0.5 mA max.
Voltage (V.DC.)
5V
Voltage Accuracy
±2%
AEC60-24S
AEC60-48S
60W
60W
60W
Current (mA) max
10,000
Line Regulation (LL-HL) (typ.)
±1%
Load Regulation (5-100%) (typ.)
±1%
9V
12V
15V
24V
48V
6,660
5,000
4,000
2,500
1,250
86%
86%
86%
86%
Minimum Load
1%
Maximum Capacitive Load
470-23,000µF depending on model
Ripple
<0.2% Vout +40mV max (Vp-p)
Noise
<0.5% Vout +50mV max (Vp-p)
82%
Trim
±10%
Hold-up Time
10 ms min.
Switching Frequency
100 kHz
Over Power Protection
Auto recovery
Over Voltage Protection
Zener diode clamp
Short Circuit Protection
Auto recovery
Input-Output (V.AC)
3000V
Input-FG
(V.AC)
1500V
Output-FG
.(V.AC)
84%
500V
-40°C…+70°C (with derating)
Storage Temperature
-50°C…+85°C
Temperature coefficient
±0.02%/°C
Humidity
95% RH
MTBF
>130,000 h @ 25°C (MIL-HDBK-217F)
Dimension (L x W x H)
4.3 x 2.3 x 1.18 Inches
Weight
310 g
Cooling Method
Free air convection
Safety
Agency Approvals
EMI
CE, UL60950
EMC
(Conducted & Radiated Emission)
Physical
AEC60-15S
47-63 Hz
Inrush Current (<2ms)
Operating Temperature
Environment
60W
Current (Full load)
Efficiency (at 230V)
Protection
AEC60-12S
60W
85-265 VAC or 100-370 VDC
Frequency (Hz)
Input
AEC60-9S
EMS (Noise Immunity)
( 109.0 x 58.5 x 30 mm ) Tolerance ±0.5 mm
EN 55022 class B
EN 55024
All specifications valid at nominal input voltage, full load and +25°C after warm-up time unless otherwise stated.
http://www.archcorp.com.tw
TEL: +886-2-26989508 FAX: +886-2-26981319
-1-
VER : A_3
update : 98.06.09
AC-DC Medical
AEC60 SERIES
60 Watts
Measured with 0.1μ 50V // 47μ 50V Ceramic Cap. Cross to output
MECHANICAL DIMENSION
( Top View )
PIN#
SINGLE
1
AC IN (N)
2
AC IN (L)
3
FG
4
+DC OUT
5
-DC OUT
6
Trim
DERATING
BLOCK DIAGRAM
http://www.archcorp.com.tw
TEL: +886-2-26989508 FAX: +886-2-26981319