ASM-SENSOR 3286-20

3286-20
CLAMP ON POWER HiTESTER
Power measuring instruments
All Powerful
Effective input current level
1.00 A to 1000 A
W
VA var
600.0kW max.(1ø)
COS
±1.000
±1.000 (±90.0º)
(±90.0º)
Harmonics
Up
Up to
to 20th
C A T III 6 0 0 V
http://www.hioki.co.jp/
1
Functionality
and Safety
80 mm ✕ 20 mm
busbar max.
Applications
ø 55
mm
max.
❏ Use as a single-phase power meter
RMS
V
Effective power/ voltage/ current
Load
AC
1ø Power meter mode
Source
Voltage
600 Vrms max.
Current
AC
RMS
A
1000 Arms max.
This displays the result of
vector calculations on
PT/CT conversion ratio settings are not possible. single-phase power.
Apparent/ reactive power
Power factor
(effective value
power factor)
Power
W
VA var
600.0kW max.(1ø)
Phase detection ❏ Measure phase on a single-phase line
RST
1ø Power Factor meter mode
The phase angle between the voltage waveform and the current
waveform is found, and the power factor (cos ø) and reactivity
(sin ø) are calculated and displayed.
Normal/ Reverse/ Missing
Power factor (cos ø)
Power factor
COS
ø
±1.000 (±90.0º)
Peak
Peak
Reactivity (sin ø)
Phase angle (ø)
value
1700 A peak max.
Frequency
Hz
1000 Hz max.
Harmonics
Harmonics
Up to 20th
The 3286-20 provides the following 2 types of power factor measurement. If
the waveform includes harmonic distortion, there will be a difference between
the two measurement values, and the method must be selected accordingly.
●Power factor derived by phase discrimination (cos ø):
1ø Power Factor meter and 3ø Power Factor meter mode
From the phase information for the fundamental frequency component, cos ø is
calculated. This is suitable for assessing the quality of a power supply.
●Power factor (effective value power factor)
derived from effective power ÷ apparent power: 1ø Power meter mode
This is calculated from the power value including harmonic components
(effective power ÷ apparent power). This is suitable for evaluating the
performance of standalone load equipment and similar cases.
* It is not possible to calculate the effective power factor of a three-phase line.
2
Packed into a Handheld Unit
Helpful battery capacity check
Whenever the unit is powered on, and
while the record function is operating, the
battery capacity can be checked to avoid
battery exhaustion during measurement.
❏ Simple checking of three-phase lines
❏ For harmonic suppression
3ø Power Factor meter mode
Load
Source
Power factor (cos ø)
Harmonic measurement function
Harmonics effective value/
total harmonic distortion
Harmonics effective value/
harmonic percentage
Phase angle (ø) Reactivity (sin ø)
Harmonic coefficients Total harmonic distortion
Ex. THD-R is 65.9%
Ex. Fundamental
Harmonic coefficients Harmonic percentage
Ex. 3rd order is 33.7 A
component is 40.3 A
Balanced three-phase power can also be displayed
Effective power/ voltage/ current
Apparent/ reactive
power
Phase detection
Ratio to case in which
fundamental component is
100%
The analysis values for coefficients for each of the harmonics
from 1 to 20 of voltage or current can be displayed.
❏ External output of data
Output to PC
(Optional 9636-01 required)
check
The 3286-20's three-phase power measurement method calculates and
displays the power values for a sine wave input at 50/60 Hz, assuming
it is balanced and there is no distortion. Accurate measurement is not
possible on a three-phase line if it is not balanced, for example when
controlled by an inverter or thyristor.
Cord length:
approx 2m
Since there is no integration function, it is not possible to measure total energy consumed (Wh).
❏ Check power supply fluctuations
Max. and min. value displays
Using the record function, it is
possible to check the amplitude of
fluctuations.
Record elapsed time
Example: 4 h 25 m
V
Waveform display is not available
Care must be taken with regard to battery life
Record peak value fluctuations
Easily check peak value fluctuations.
Please note that waveforms with amplitudes at or
less than 250ms cannot be detected accurately
+
Data output connector RS-232C
interface by optical insulating coupler
● OS:Windows 95, 98, NT4.0, 2000, Me*1
● Connector: D-sub 9 pin
● Fetch interval: 6s/30s/1m/5m/10m.
● Buffer size: 32,700 max.
Care must be taken with regard to battery life
*1. Windows is a registered trademark of Microsoft Corporation.
Printer output to 9442 (optional)
The output is sent
to the printer each
time the 3286-20
HOLD key is
pressed.
(For about 1 sec.)
● Printing method: Thermal serial
dot matrix ● Paper width: 112 mm
● Printing speed: 52.5cps ●
Power supply: 9443 AC
ADAPTER or supplied nickelhydride battery (capable of printing
about 3000 lines on full charge from
9443) ● Dimensions and mass:
160W ✕ 66.5H ✕ 170D mm; 580 g
9636
9443-02
RS-232C CABLE AC ADAPTER
(For the EU)
9443-03
(For the America)
0
-
Waveform display is not available
Cord length
approx 1.3m
Not for use with
Model 3286-20
3
■ Basic specifications
Measurement items : Voltage, current, voltage/current peak, effective/ reactive /
apparent power(Single-phase or 3-phase), power factor,
reactivity, phase angle, frequency, phase detection(3phase), voltage/current harmonic levels(up to 20th)
Measurable
conductor diameter : ø55mm (2.16"), 80 mm ✕ 20 mm busbar max.
: LCD, digital (6000 counts)
Display
Rectification method : RMS (true root mean square value)
Display update rate : NORMAL approx. 1 time/ sec, SLOW 1 time/ 3-sec
at HARM meas. approx. 1 time/ 2-sec
Analog response time : 4.0 seconds or less (when input is changed from 0% to 90% of range.)
[Voltage/ Current/ Power measurement]
AC Voltage
Range Table
150.0 V
Detection method :
Power factor (cos ø) :
:
Phase angle
Reactivity (sin ø) :
Phase discrimination by phase detection (zero crossing)
0.000 (lead) to 1.000 to 0.000 (lag)
90.0˚(lead) to 0.0˚to 90.0˚(lag)
0.000 (lead) to 1.000 to 0.000 (lag)
[Frequency measurement] Effective in the voltage and current functions
Measurement range : 30.0 Hz to 100 Hz (at 100.0 Hz range)
100 Hz to 1000Hz (at 1000 Hz range)
Min. input level : Voltage 10 Vrms-sine wave, Current 1 Arms-sine wave
[Wave peak measurement] Effective in the voltage and current functions
AC Current
20.00 A
200.0 A
1000 A
Single-phase 3.000 kW
*3-phase
(balanced load) 6.000 kW
30.00 kW
150.0 kW
60.00 kW
300.0 kW
300.0
Single phase 6.000 kW
60.00 kW 300.0 kW
V *3-phase
(balanced load) 6.000/12.00 kW 60.00/120.0 kW 600.0 kW
600
V
Single phase 12.00 kW
*3-phase
(balanced load) 24.00 kW
[Power factor/ Phase angle/ Reactivity measurement]
120.0 kW
600.0 kW
240.0 kW 600.0/1200 kW
*3-phase power is calculated and displayed on the basis of a balanced, 50/60 Hz, sine wave input.
For apparent power and reactive power, the unit of watts in the above table is replaced by VA and var respectively.
Effective value P.F. :
Max. allowable current :
Max. usable circuit voltage :
Effective input range :
0.000 (lead) to 1.000 to 0.000 (lag); 1ø only
1000 Arms cont.
600 Vrms (insulated conductor)
Voltage: 10 V to 600 V, Current: 1 A to 1000A,
Power: 80 V to 600 V and 1 A to 1000 A
Min. Display value : Voltage: 0.6 Vrms, Current: 0.06 Arms
Display indication range : 5 or less are zero-suppressed, and the upper limit is to 125%
of the range setting (to 100% for the 1000 A range)
(RMS value)
Circuit dynamic : 2.5 or less (1000 A and 600 V range is 1.7 or less)
Measurement range : 150 (375 peak) / 300 (750 peak) / 600 (1020 peak) V
20 (50 peak) / 200 (500 peak) / 1000 (1700 peak) A
Effective Input Range : Effective value of sine wave is within effective input
permissible in the range and within circuit dynamic
[Harmonic measurement] Effective in the voltage and current functions
Measurement items : Level of each order, percentage of each order and total
harmonic distortion (THD-F and THD-R)
Measurement range : Fundamental frequency 50 / 60 Hz
Window width : 1 cycle (50 / 60 Hz), Data points: 256 points
Window type : Rectangular
Orders analyzed : Up to 20th
[Other functions]
Phase detection : Normal/ reverse/ missing (at 3-phase balanced load)
: MAX. value and MIN. value (Effective in the voltage,
Record
current and effective / apparent power functions)
Battery capacity : Displayed in % when the unit is powered on
: Holds display
Data hold
Auto power off : Approx. 10 minutes, buzzer sounds just before power is
turned off, can be extended or cancelled
: RS-232C interface by optical insulating coupler
Data output
■ Measurement accuracy (23 ˚C±5 ˚C (73˚F ±9˚F), Less than 80%rh., sine wave input, power factor = 1)
30 Hz to 45 Hz 45 Hz to 66 Hz 66 Hz to 1 kHz
Voltage ±1.5 %rdg.±5 dgt. ±1.0 %rdg.±3 dgt.
Current
not rated
±1.5%rdg.±5 dgt.
±1.3 %rdg.±3 dgt. ±2.0 %rdg.±5 dgt.
Accuracy guaranteed only for 50/60 Hz (COS ø=1)
Power
: ±0.3 % rdg.±1 dgt. (at 100.0Hz range)
±1.0 % rdg.±1 dgt. (at 1000Hz range)
: ±3.0 %rdg.±5 dgt. (45 Hz to 1 kHz)
Wave peak
Thermal coefficient : Voltage and current: within ±0.1✕Accuracy/ ˚C (0 to 40˚C)
Phase: within ±2˚ (0 to 40˚C)
Conductor position : Within ±0.7 % in any direction from the center of sensor
External magneticfield : 400A/m corresponds to 1.00 A max.
Power factor influence : ±10.0 % f.s. (cos ø=0.5)
: Order
Harmonics
Order
Accuracy
Accuracy
Frequency
[Voltage/ Current/ Power measurement]
Single-phase: ±2.3 %rdg.±5 dgt.
3-phase: ±3.0 %rdg.±10 dgt.(at balanced load)
1
: ±3˚
Phase angle
Power factor (cos ø) : ±3˚±2 dgt.
2 to 6
7, 8
■ General Specifications
±3.0 %rdg.±10 dgt.
±3.5 %rdg.±10 dgt.
±4.5 %rdg.±10 dgt.
9, 10
11 to 15
16 to 20
±5.0 %rdg.±10 dgt.
±7.0 %rdg.±10 dgt.
±10.0 %rdg.±10 dgt.
Applicable standards : Safety
EN61010-1:1992+A2:1995 CAT III 600V
EN61010-2-031:1996, EN61010-2-032:1995
EN60529:1991 IP40
: EMC
EN61326-1:1997+A1:1998+A2:2001
Withstand voltage : 5.55 kV AC between clamp and frame, between
(50/60 Hz, 1 minute) clamp and circuitry
Measurement method : Digital sampling method
Operating temperature : 0ºC to 40ºC, 80%rh or less, no condensation
Storage temperature : -10ºC to 50ºC, no condensation
Power supply : 6LR61 alkaline battery✕1 (continuous operation max. 25 hours)
(9V battery)
6F22 manganese battery✕1 (continuous operation max. 10 hours)
Dimensions, mass : Approx 100 W ✕ 287 H ✕ 39 D mm, Approx 650g
3286-20 CLAMP ON POWER HiTESTER
Options
9635-01 VOLTAGE CORD
9636-01 RS-232C PACKAGE
9442
PRINTER
(Includes 9635 VOLTAGE CORD, 9245 CARRYING CASE, HAND STRAP)
(Approx 3.94″(W )11.3″ (H)1.54″ (D), Approx 22.6 oz.)
9636
9443-02
9443-03
1196
Cord length
approx 3m
9635-01
RS-232C CABLE (For 9442 printer)
AC ADAPTER (For 9442 printer, EU)
AC ADAPTER (For 9442 printer, America)
RECORDING PAPER (For printer, 10 rolls)
Cord length
approx 3m
When ordering the 9442 PRINTER, also order the 9636 RS-232C CABLE required for
connection to the 3286-20, and 9443 AC ADAPTER.
DISTRIBUTED BY
HEAD OFFICE :
81 Koizumi, Ueda, Nagano, 386-1192, Japan
TEL +81-268-28-0562 / FAX +81-268-28-0568
E-mail: os-com@ hioki.co.jp
HIOKI USA CORPORATION :
6 Corporate Drive, Cranbury, NJ 08512 USA
TEL +1-609-409-9109 / FAX +1-609-409-9108
E-mail: hioki@ hiokiusa.com
Shanghai Representative Office :
1704 Shanghai Times Square Office
93 Huaihai Zhong Road
Shanghai, 200021, P.R.China
TEL +86-21-6391-0090, 0092
FAX +86-21-6391-0360
E-mail: [email protected]
All information correct as of Oct. 3, 2003. All specifications are subject to change without notice.
328620E2-3XB-05K
Printed in Japan