TO18 Plastic
IR Emitter
FEATURES
• Min/max radiated power density selection.
• Good optical to mechanical alignment
• High radiance level.
• Coloured body gives easy recognition
from Phototransistor.
MECHANICAL DATA
DESCRIPTION
The BOE100 is a 880nm
AlGaAs LED encapsulated in a
clear,purple tinted plastic TO46
package
Do Not Scale
4.67 ±0.15
5.59 ±0.25
REFERENCE SURFACE
0.76 NOM
CATHODE
20.3 MIN
ANODE
1.27 NOM
NOTES
1. DIMENSIONS mm
2. TOLERANCE +/- 0.25 UNLESS STATED
3. TAB DENOTES CATHODE
2.54 NOM
0.5 SQ NOM
5.46 ±0.25
45°
BEDFORD OPTO TECHNOLOGY LTD
1.BIGGAR BUSINESS PARK, BIGGAR,LANARKSHIRE, ML12 6FX
Tel: +44 (0) 1899 221221 Fax: +44 (0) 1899 221009
Website: bot.co.uk E-mail: [email protected]
PAGE 1
ISS A 15.4.02
R0.56
BOE100
TO18 Plastic
IR Emitter
ABSOLUTE MAXIMUM RATINGS (25oC unless otherwise noted)
STORAGE TEMP
-40 C TO +100oC
OPERATING TEMP
-40 C TO 100oC
100mA
CONTINUOUS FORWARD CURRENT
REVERSE VOLTAGE
5.0V
POWER DISSIPATION
200mW (1)
240oC for 5secs(2,3,5)
LEAD SOLDERING TEMPERATURE (Iron)
260oC for 10secs
LEAD SOLDERING TEMPERATURE9(Flow)
OPTO ELECTRONIC DATA(Ta=25oC unless stated)
PARAMETER
SYMBOL
MIN
TYP
MAX
UNITS
TEST CONDISTIONS
Forward Voltage
Vf
1.70
V
If = 20mA
Reverse leakage Current
Ir
10
μA
Vr=5.0V
Peak Emission Wavelength
λp
880
nm
If=20mA
Emission Angle at ½ Radiated Power
Density.
Θ
±35
deg
Radiant incidence
EΘ
16
26
mW/sqcm
If=100mA(6,7)
NOTES
o
BEDFORD OPTO TECHNOLOGY LTD
1,BIGGAR BUSINESS PARK, BIGGAR,LANARKSHIRE, ML12 6FX
Tel: +44 (0) 1899 221221 Fax: +44 (0) 1899 221009
Website: bot.co.uk E-mail: [email protected]
PAGE 2
ISS A 15.4.02
o
1. Derate power dissipation linearly at 2.7mW/ C above 25 C.
2. RMA flux is recommended.
3. Methonal or Isopropylalcohols are recommended as cleaning agents.
4. Solder iron tip 1.6mm minimum from housing.
5. Leads not to be under stress or tension.
6. Measurment taken at the end of a 100μS pulse.
7. EΘ is a measure of the average apertured radiant energy incident
upon a sensing area 6.35mm diameter perpendicular to and centred on
the mechanical axis of the lens and 10.7mm from the measurement surface.Eθis not necessarily uniform within the measurement area.