LF198,LF198A,LF298,LF398,LF398A LF198/LF298/LF398, LF198A/LF398A Monolithic Sample-and-Hold Circuits Literature Number: SNOSBI3A LF198/LF298/LF398, LF198A/LF398A Monolithic Sample-and-Hold Circuits General Description Features The LF198/LF298/LF398 are monolithic sample-and-hold circuits which utilize BI-FET technology to obtain ultra-high dc accuracy with fast acquisition of signal and low droop rate. Operating as a unity gain follower, dc gain accuracy is 0.002% typical and acquisition time is as low as 6 µs to 0.01%. A bipolar input stage is used to achieve low offset voltage and wide bandwidth. Input offset adjust is accomplished with a single pin, and does not degrade input offset drift. The wide bandwidth allows the LF198 to be included inside the feedback loop of 1 MHz op amps without having stability problems. Input impedance of 1010Ω allows high source impedances to be used without degrading accuracy. P-channel junction FET’s are combined with bipolar devices in the output amplifier to give droop rates as low as 5 mV/min with a 1 µF hold capacitor. The JFET’s have much lower noise than MOS devices used in previous designs and do not exhibit high temperature instabilities. The overall design guarantees no feed-through from input to output in the hold mode, even for input signals equal to the supply voltages. n Operates from ± 5V to ± 18V supplies n Less than 10 µs acquisition time n TTL, PMOS, CMOS compatible logic input n 0.5 mV typical hold step at Ch = 0.01 µF n Low input offset n 0.002% gain accuracy n Low output noise in hold mode n Input characteristics do not change during hold mode n High supply rejection ratio in sample or hold n Wide bandwidth n Space qualified, JM38510 Logic inputs on the LF198 are fully differential with low input current, allowing direct connection to TTL, PMOS, and CMOS. Differential threshold is 1.4V. The LF198 will operate from ± 5V to ± 18V supplies. An “A” version is available with tightened electrical specifications. Typical Connection and Performance Curve Acquisition Time DS005692-32 DS005692-16 Functional Diagram DS005692-1 © 2000 National Semiconductor Corporation DS005692 www.national.com LF198/LF298/LF398, LF198A/LF398A Monolithic Sample-and-Hold Circuits July 2000 LF198/LF298/LF398, LF198A/LF398A Absolute Maximum Ratings (Note 1) Hold Capacitor Short Circuit Duration Lead Temperature (Note 4) H package (Soldering, 10 sec.) N package (Soldering, 10 sec.) M package: Vapor Phase (60 sec.) Infrared (15 sec.) Thermal Resistance (θJA) (typicals) H package 215˚C/W (Board mount in still air) 85˚C/W (Board mount in 400LF/min air flow) N package 115˚C/W M package 106˚C/W θJC (H package, typical) 20˚C/W If Military/Aerospace specified devices are required, please contact the National Semiconductor Sales Office/ Distributors for availability and specifications. ± 18V Supply Voltage Power Dissipation (Package Limitation) (Note 2) 500 mW Operating Ambient Temperature Range LF198/LF198A −55˚C to +125˚C LF298 −25˚C to +85˚C LF398/LF398A 0˚C to +70˚C Storage Temperature Range −65˚C to +150˚C Input Voltage Equal to Supply Voltage Logic To Logic Reference Differential Voltage (Note 3) +7V, −30V Output Short Circuit Duration Indefinite 10 sec 260˚C 260˚C 215˚C 220˚C Electrical Characteristics The following specifcations apply for −VS + 3.5V ≤ VIN ≤ +VS − 3.5V, +VS = +15V, −VS = −15V, TA = Tj = 25˚C, Ch = 0.01 µF, RL = 10 kΩ, LOGIC REFERENCE = 0V, LOGIC HIGH = 2.5V, LOGIC LOW = 0V unless otherwise specified. Parameter Conditions LF198/LF298 Min Input Offset Voltage, (Note 5) Tj = 25˚C Max 1 3 5 25 Full Temperature Range Input Bias Current, (Note 5) Min Max 2 7 mV 10 mV 50 nA 100 nA 0.01 % 10 75 10 Input Impedance Tj = 25˚C 10 Gain Error Tj = 25˚C, RL = 10k 0.002 Full Temperature Range 10 0.005 86 96 Ω 10 0.004 0.02 Tj = 25˚C, Ch = 0.01 µF Units Typ 5 Tj = 25˚C Full Temperature Range Feedthrough Attenuation Ratio LF398 Typ 0.02 80 90 % dB at 1 kHz Output Impedance Tj = 25˚C, “HOLD” mode 0.5 Full Temperature Range 2 0.5 4 4 Ω 6 Ω “HOLD” Step, (Note 6) Tj = 25˚C, Ch = 0.01 µF, VOUT = 0 0.5 2.0 1.0 2.5 mV Supply Current, (Note 5) Tj≥25˚C 4.5 5.5 4.5 6.5 mA Logic and Logic Reference Input Tj = 25˚C 2 10 2 10 µA Leakage Current into Hold Tj = 25˚C, (Note 7) 30 100 30 200 pA Capacitor (Note 5) Hold Mode Acquisition Time to 0.1% ∆VOUT = 10V, Ch = 1000 pF 4 4 Current µs Ch = 0.01 µF 20 20 µs Hold Capacitor Charging Current VIN−VOUT = 2V 5 5 mA Supply Voltage Rejection Ratio VOUT = 0 80 110 80 110 dB Differential Logic Threshold Tj = 25˚C 0.8 1.4 2.4 0.8 1.4 2.4 V Input Offset Voltage, (Note 5) Tj = 25˚C 1 1 2 2 mV 3 mV 5 25 10 25 nA 50 nA Full Temperature Range Input Bias Current, (Note 5) 2 Tj = 25˚C Full Temperature Range www.national.com 75 2 Parameter Conditions LF198A Min Input Impedance Gain Error Typ Tj = 25˚C 1010 Tj = 25˚C, RL = 10k 0.002 Full Temperature Range Feedthrough Attenuation Ratio LF398A Max Min Units Typ Max Ω 1010 0.005 0.004 0.005 0.01 Tj = 25˚C, Ch = 0.01 µF 86 96 0.01 86 90 % % dB at 1 kHz Output Impedance Tj = 25˚C, “HOLD” mode 0.5 Full Temperature Range “HOLD” Step, (Note 6) 1 0.5 4 1 Ω 6 Ω Tj = 25˚C, Ch = 0.01µF, VOUT = 0 0.5 1 1.0 1 mV Supply Current, (Note 5) Tj≥25˚C 4.5 5.5 4.5 6.5 mA Logic and Logic Reference Input Tj = 25˚C 2 10 2 10 µA Tj = 25˚C, (Note 7) 30 100 30 100 pA Current Leakage Current into Hold Capacitor (Note 5) Hold Mode Acquisition Time to 0.1% ∆VOUT = 10V, Ch = 1000 pF 4 6 4 6 µs Ch = 0.01 µF 20 25 20 25 µs Hold Capacitor Charging Current VIN−VOUT = 2V Supply Voltage Rejection Ratio VOUT = 0 90 110 Differential Logic Threshold Tj = 25˚C 0.8 1.4 5 5 2.4 90 110 0.8 1.4 mA dB 2.4 V Note 1: “Absolute Maximum Ratings” indicate limits beyond which damage to the device may occur. Operating Ratings indicate conditions for which the device is functional, but do not guarantee specific performance limits. Note 2: The maximum power dissipation must be derated at elevated temperatures and is dictated by TJMAX, θJA, and the ambient temperature, TA. The maximum allowable power dissipation at any temperature is PD = (TJMAX − TA)/θJA, or the number given in the Absolute Maximum Ratings, whichever is lower. The maximum junction temperature, TJMAX, for the LF198/LF198A is 150˚C; for the LF298, 115˚C; and for the LF398/LF398A, 100˚C. Note 3: Although the differential voltage may not exceed the limits given, the common-mode voltage on the logic pins may be equal to the supply voltages without causing damage to the circuit. For proper logic operation, however, one of the logic pins must always be at least 2V below the positive supply and 3V above the negative supply. Note 4: See AN-450 “Surface Mounting Methods and their effects on Product Reliability” for other methods of soldering surface mount devices. Note 5: These parameters guaranteed over a supply voltage range of ± 5 to ± 18V, and an input range of −VS + 3.5V ≤ VIN ≤ +VS − 3.5V. Note 6: Hold step is sensitive to stray capacitive coupling between input logic signals and the hold capacitor. 1 pF, for instance, will create an additional 0.5 mV step with a 5V logic swing and a 0.01µF hold capacitor. Magnitude of the hold step is inversely proportional to hold capacitor value. Note 7: Leakage current is measured at a junction temperature of 25˚C. The effects of junction temperature rise due to power dissipation or elevated ambient can be calculated by doubling the 25˚C value for each 11˚C increase in chip temperature. Leakage is guaranteed over full input signal range. Note 8: A military RETS electrical test specification is available on request. The LF198 may also be procured to Standard Military Drawing #5962-8760801GA or to MIL-STD-38510 part ID JM38510/12501SGA. Typical Performance Characteristics Aperture Time (Note 9) Dielectric Absorption Error in Hold Capacitor Dynamic Sampling Error DS005692-19 DS005692-17 DS005692-18 Note 9: See Definition of Terms 3 www.national.com LF198/LF298/LF398, LF198A/LF398A Electrical Characteristics The following specifcations apply for −VS + 3.5V ≤ VIN ≤ +VS − 3.5V, +VS = +15V, −VS = −15V, TA = Tj = 25˚C, Ch = 0.01 µF, RL = 10 kΩ, LOGIC REFERENCE = 0V, LOGIC HIGH = 2.5V, LOGIC LOW = 0V unless otherwise specified. LF198/LF298/LF398, LF198A/LF398A Typical Performance Characteristics Output Droop Rate (Continued) Hold Step “Hold” Settling Time (Note 10) DS005692-21 DS005692-20 DS005692-22 Leakage Current into Hold Capacitor Phase and Gain (Input to Output, Small Signal) DS005692-25 DS005692-23 Power Supply Rejection DS005692-24 Output Short Circuit Current DS005692-27 DS005692-26 Note 10: See Definition www.national.com Gain Error 4 Output Noise DS005692-28 Input Bias Current (Continued) Feedthrough Rejection Ratio (Hold Mode) Hold Step vs Input Voltage DS005692-31 DS005692-29 DS005692-30 Output Transient at Start of Sample Mode Output Transient at Start of Hold Mode DS005692-12 DS005692-13 Logic Input Configurations TTL & CMOS 3V ≤ VLOGIC (Hi State) ≤ 7V DS005692-33 Threshold = 1.4V DS005692-34 Threshold = 1.4V *Select for 2.8V at pin 8 5 www.national.com LF198/LF298/LF398, LF198A/LF398A Typical Performance Characteristics LF198/LF298/LF398, LF198A/LF398A Logic Input Configurations (Continued) CMOS 7V ≤ VLOGIC (Hi State) ≤ 15V DS005692-35 Threshold = 0.6 (V+) + 1.4V DS005692-36 Threshold = 0.6 (V+) − 1.4V Op Amp Drive DS005692-37 Threshold ≈ +4V DS005692-38 Threshold = −4V Application Hints Hold Capacitor Hold step, acquisition time, and droop rate are the major trade-offs in the selection of a hold capacitor value. Size and cost may also become important for larger values. Use of the curves included with this data sheet should be helpful in selecting a reasonable value of capacitance. Keep in mind that for fast repetition rates or tracking fast signals, the capacitor drive currents may cause a significant temperature rise in the LF198. A significant source of error in an accurate sample and hold circuit is dielectric absorption in the hold capacitor. A mylar cap, for instance, may “sag back” up to 0.2% after a quick change in voltage. A long sample time is required before the circuit can be put back into the hold mode with this type of capacitor. Dielectrics with very low hysteresis are polystyrene, polypropylene, and Teflon. Other types such as mica and polycarbonate are not nearly as good. The advantage of polypropylene over polystyrene is that it extends the maximum ambient temperature from 85˚C to 100˚C. Most ceramic capacitors are unusable with > 1% hysteresis. Ceramic “NPO” or “COG” capacitors are now available for 125˚C operation and also have low dielectric absorption. For more exact data, see the curve Dielectric Absorption Error. The hysteresis numbers on the curve are final values, taken after full relaxation. The hysteresis error can be significantly www.national.com reduced if the output of the LF198 is digitized quickly after the hold mode is initiated. The hysteresis relaxation time constant in polypropylene, for instance, is 10 — 50 ms. If A-to-D conversion can be made within 1 ms, hysteresis error will be reduced by a factor of ten. DC and AC Zeroing DC zeroing is accomplished by connecting the offset adjust pin to the wiper of a 1 kΩ potentiometer which has one end tied to V+ and the other end tied through a resistor to ground. The resistor should be selected to give ≈0.6 mA through the 1k potentiometer. AC zeroing (hold step zeroing) can be obtained by adding an inverter with the adjustment pot tied input to output. A 10 pF capacitor from the wiper to the hold capacitor will give ± 4 mV hold step adjustment with a 0.01 µF hold capacitor and 5V logic supply. For larger logic swings, a smaller capacitor ( < 10 pF) may be used. Logic Rise Time For proper operation, logic signals into the LF198 must have a minimum dV/dt of 1.0 V/µs. Slower signals will cause excessive hold step. If a R/C network is used in front of the 6 LF198/LF298/LF398, LF198A/LF398A Application Hints (Continued) Guarding Technique logic input for signal delay, calculate the slope of the waveform at the threshold point to ensure that it is at least 1.0 V/µs. Sampling Dynamic Signals Sample error to moving input signals probably causes more confusion among sample-and-hold users than any other parameter. The primary reason for this is that many users make the assumption that the sample and hold amplifier is truly locked on to the input signal while in the sample mode. In actuality, there are finite phase delays through the circuit creating an input-output differential for fast moving signals. In addition, although the output may have settled, the hold capacitor has an additional lag due to the 300Ω series resistor on the chip. This means that at the moment the “hold” command arrives, the hold capacitor voltage may be somewhat different than the actual analog input. The effect of these delays is opposite to the effect created by delays in the logic which switches the circuit from sample to hold. For example, consider an analog input of 20 Vp-p at 10 kHz. Maximum dV/dt is 0.6 V/µs. With no analog phase delay and 100 ns logic delay, one could expect up to (0.1 µs) (0.6V/µs) = 60 mVerror if the “hold” signal arrived near maximum dV/dt of the input. A positive-going input would give a +60 mV error. Now assume a 1 MHz (3 dB) bandwidth for the overall analog loop. This generates a phase delay of 160 ns. If the hold capacitor sees this exact delay, then error due to analog delay will be (0.16 µs) (0.6 V/µs) = −96 mV. Total output error is +60 mV (digital) −96 mV (analog) for a total of −36 mV. To add to the confusion, analog delay is proportioned to hold capacitor value while digital delay remains constant. A family of curves (dynamic sampling error) is included to help estimate errors. A curve labeled Aperture Time has been included for sampling conditions where the input is steady during the sampling period, but may experience a sudden change nearly coincident with the “hold” command. This curve is based on a 1 mV error fed into the output. A second curve, Hold Settling Time indicates the time required for the output to settle to 1 mV after the “hold” command. DS005692-5 Use 10-pin layout. Guard around Chis tied to output. Digital Feedthrough Fast rise time logic signals can cause hold errors by feeding externally into the analog input at the same time the amplifier is put into the hold mode. To minimize this problem, board layout should keep logic lines as far as possible from the analog input and the Ch pin. Grounded guarding traces may also be used around the input line, especially if it is driven from a high impedance source. Reducing high amplitude logic signals to 2.5V will also help. 7 www.national.com LF198/LF298/LF398, LF198A/LF398A Typical Applications X1000 Sample & Hold Sample and Difference Circuit (Output Follows Input in Hold Mode) DS005692-40 VOUT = VB + ∆VIN(HOLD MODE) DS005692-39 *For lower gains, the LM108 must be frequency compensated Ramp Generator with Variable Reset Level Integrator with Programmable Reset Level DS005692-42 DS005692-43 www.national.com 8 LF198/LF298/LF398, LF198A/LF398A Typical Applications (Continued) Output Holds at Average of Sampled Input Increased Slew Current DS005692-46 DS005692-47 Reset Stabilized Amplifier (Gain of 1000) Fast Acquisition, Low Droop Sample & Hold DS005692-49 DS005692-50 9 www.national.com LF198/LF298/LF398, LF198A/LF398A Typical Applications (Continued) Synchronous Correlator for Recovering Signals Below Noise Level 2–Channel Switch DS005692-53 A B Gain 1 ± 0.02% 1 ± 0.2% ZIN 1010Ω 47 kΩ BW . 1 MHz . 400 kHz Crosstalk −90 dB −90 dB ≤ 6 mV ≤ 75 mV @ 1 kHz Offset DS005692-52 DC & AC Zeroing Staircase Generator DS005692-59 DS005692-55 *Select for step height 50k → ≅ 1V Step www.national.com 10 LF198/LF298/LF398, LF198A/LF398A Typical Applications (Continued) Differential Hold Capacitor Hysteresis Compensation DS005692-56 DS005692-57 **Adjust for amplitude Definition of Terms Hold Settling Time: The time required for the output to settle within 1 mV of final value after the “hold” logic command. Dynamic Sampling Error: The error introduced into the held output due to a changing analog input at the time the hold command is given. Error is expressed in mV with a given hold capacitor value and input slew rate. Note that this error term occurs even for long sample times. Aperture Time: The delay required between “Hold” command and an input analog transition, so that the transition does not affect the held output. Hold Step: The voltage step at the output of the sample and hold when switching from sample mode to hold mode with a steady (dc) analog input voltage. Logic swing is 5V. Acquisition Time: The time required to acquire a new analog input voltage with an output step of 10V. Note that acquisition time is not just the time required for the output to settle, but also includes the time required for all internal nodes to settle so that the output assumes the proper value when switched to the hold mode. Gain Error: The ratio of output voltage swing to input voltage swing in the sample mode expressed as a per cent difference. Connection Diagrams Dual-In-Line Package Small-Outline Package Metal Can Package DS005692-15 DS005692-11 Order Number LF398N or LF398AN See NS Package Number N08E Order Number LF298M or LF398M See NS Package Number M14A DS005692-14 Order Number LF198H, LF198H/883, LF298H, LF398H, LF198AH or LF398AH See NS Package Number H08C (Note 8) 11 www.national.com LF198/LF298/LF398, LF198A/LF398A Physical Dimensions inches (millimeters) unless otherwise noted Metal Can Package (H) Order Number LF198H, LF298H, LF398H, LF198AH or LF398AH NS Package Number H08C Molded Small-Outline Package (M) Order Number LF298M or LF398M NS Package Number M14A www.national.com 12 inches (millimeters) unless otherwise noted (Continued) Molded Dual-In-Line Package (N) Order Number LF398N or LF398AN NS Package Number N08E LIFE SUPPORT POLICY NATIONAL’S PRODUCTS ARE NOT AUTHORIZED FOR USE AS CRITICAL COMPONENTS IN LIFE SUPPORT DEVICES OR SYSTEMS WITHOUT THE EXPRESS WRITTEN APPROVAL OF THE PRESIDENT AND GENERAL COUNSEL OF NATIONAL SEMICONDUCTOR CORPORATION. As used herein: 1. Life support devices or systems are devices or systems which, (a) are intended for surgical implant into the body, or (b) support or sustain life, and whose failure to perform when properly used in accordance with instructions for use provided in the labeling, can be reasonably expected to result in a significant injury to the user. National Semiconductor Corporation Americas Tel: 1-800-272-9959 Fax: 1-800-737-7018 Email: [email protected] www.national.com National Semiconductor Europe Fax: +49 (0) 180-530 85 86 Email: [email protected] Deutsch Tel: +49 (0) 69 9508 6208 English Tel: +44 (0) 870 24 0 2171 Français Tel: +33 (0) 1 41 91 8790 2. A critical component is any component of a life support device or system whose failure to perform can be reasonably expected to cause the failure of the life support device or system, or to affect its safety or effectiveness. National Semiconductor Asia Pacific Customer Response Group Tel: 65-2544466 Fax: 65-2504466 Email: [email protected] National Semiconductor Japan Ltd. Tel: 81-3-5639-7560 Fax: 81-3-5639-7507 National does not assume any responsibility for use of any circuitry described, no circuit patent licenses are implied and National reserves the right at any time without notice to change said circuitry and specifications. LF198/LF298/LF398, LF198A/LF398A Monolithic Sample-and-Hold Circuits Physical Dimensions IMPORTANT NOTICE Texas Instruments Incorporated and its subsidiaries (TI) reserve the right to make corrections, modifications, enhancements, improvements, and other changes to its products and services at any time and to discontinue any product or service without notice. Customers should obtain the latest relevant information before placing orders and should verify that such information is current and complete. All products are sold subject to TI’s terms and conditions of sale supplied at the time of order acknowledgment. TI warrants performance of its hardware products to the specifications applicable at the time of sale in accordance with TI’s standard warranty. Testing and other quality control techniques are used to the extent TI deems necessary to support this warranty. Except where mandated by government requirements, testing of all parameters of each product is not necessarily performed. TI assumes no liability for applications assistance or customer product design. Customers are responsible for their products and applications using TI components. To minimize the risks associated with customer products and applications, customers should provide adequate design and operating safeguards. TI does not warrant or represent that any license, either express or implied, is granted under any TI patent right, copyright, mask work right, or other TI intellectual property right relating to any combination, machine, or process in which TI products or services are used. Information published by TI regarding third-party products or services does not constitute a license from TI to use such products or services or a warranty or endorsement thereof. Use of such information may require a license from a third party under the patents or other intellectual property of the third party, or a license from TI under the patents or other intellectual property of TI. Reproduction of TI information in TI data books or data sheets is permissible only if reproduction is without alteration and is accompanied by all associated warranties, conditions, limitations, and notices. Reproduction of this information with alteration is an unfair and deceptive business practice. TI is not responsible or liable for such altered documentation. Information of third parties may be subject to additional restrictions. Resale of TI products or services with statements different from or beyond the parameters stated by TI for that product or service voids all express and any implied warranties for the associated TI product or service and is an unfair and deceptive business practice. TI is not responsible or liable for any such statements. TI products are not authorized for use in safety-critical applications (such as life support) where a failure of the TI product would reasonably be expected to cause severe personal injury or death, unless officers of the parties have executed an agreement specifically governing such use. Buyers represent that they have all necessary expertise in the safety and regulatory ramifications of their applications, and acknowledge and agree that they are solely responsible for all legal, regulatory and safety-related requirements concerning their products and any use of TI products in such safety-critical applications, notwithstanding any applications-related information or support that may be provided by TI. Further, Buyers must fully indemnify TI and its representatives against any damages arising out of the use of TI products in such safety-critical applications. TI products are neither designed nor intended for use in military/aerospace applications or environments unless the TI products are specifically designated by TI as military-grade or "enhanced plastic." Only products designated by TI as military-grade meet military specifications. Buyers acknowledge and agree that any such use of TI products which TI has not designated as military-grade is solely at the Buyer's risk, and that they are solely responsible for compliance with all legal and regulatory requirements in connection with such use. TI products are neither designed nor intended for use in automotive applications or environments unless the specific TI products are designated by TI as compliant with ISO/TS 16949 requirements. Buyers acknowledge and agree that, if they use any non-designated products in automotive applications, TI will not be responsible for any failure to meet such requirements. Following are URLs where you can obtain information on other Texas Instruments products and application solutions: Products Applications Audio www.ti.com/audio Communications and Telecom www.ti.com/communications Amplifiers amplifier.ti.com Computers and Peripherals www.ti.com/computers Data Converters dataconverter.ti.com Consumer Electronics www.ti.com/consumer-apps DLP® Products www.dlp.com Energy and Lighting www.ti.com/energy DSP dsp.ti.com Industrial www.ti.com/industrial Clocks and Timers www.ti.com/clocks Medical www.ti.com/medical Interface interface.ti.com Security www.ti.com/security Logic logic.ti.com Space, Avionics and Defense www.ti.com/space-avionics-defense Power Mgmt power.ti.com Transportation and Automotive www.ti.com/automotive Microcontrollers microcontroller.ti.com Video and Imaging RFID www.ti-rfid.com OMAP Mobile Processors www.ti.com/omap Wireless Connectivity www.ti.com/wirelessconnectivity TI E2E Community Home Page www.ti.com/video e2e.ti.com Mailing Address: Texas Instruments, Post Office Box 655303, Dallas, Texas 75265 Copyright © 2011, Texas Instruments Incorporated