CS5532/34-BS 24-bit ∆Σ ADCs with Ultra-low-noise PGIA Features General Description Chopper-stabilized The CS5532/34 are highly integrated ∆Σ Analog-to-Digital Converters (ADCs) which use charge-balance techniques to achieve 24-bit performance. The ADCs are optimized for measuring low-level unipolar or bipolar signals in weigh scale, process control, scientific, and medical applications. PGIA (Programmable Gain Instrumentation Amplifier, 1x to 64x) – 6 nV/√Hz @ 0.1 Hz (No 1/f noise) at 64x – 1200 pA Input Current with Gains >1 Delta-sigma Analog-to-digital Converter – Linearity Error: 0.0007% FS – Noise-free Resolution: Up to 23 bits Two- or Four-channel Differential MUX Scalable Input Span via Calibration – ±5 mV to differential ±2.5V Scalable VREF Input: Up to Analog Supply Simple Three-wire Serial Interface – SPI™ and Microwire™ Compatible – Schmitt Trigger on Serial Clock (SCLK) R/W Calibration Registers Per Channel Selectable Word Rates: 6.25 to 3,840 Sps Selectable 50 or 60 Hz Rejection Power Supply Configurations – VA+ = +5 V; VA- = 0 V; VD+ = +3 V to +5 V – VA+ = +2.5 V; VA- = -2.5 V; VD+ = +3 V to +5 V – VA+ = +3 V; VA- = -3 V; VD+ = +3 V VA+ C1 AIN1+ C2 VREF+ PGIA 1,2,4,8,16 32,64 AIN1- To accommodate these applications, the ADCs come as either two-channel (CS5532) or four-channel (CS5534) devices and include a very low-noise, chopper-stabilized instrumentation amplifier (6 nV/√Hz @ 0.1 Hz) with selectable gains of 1×, 2×, 4×, 8×, 16×, 32×, and 64×. These ADCs also include a fourth-order ∆Σ modulator followed by a digital filter which provides twenty selectable output word rates of 6.25, 7.5, 12.5, 15, 25, 30, 50, 60, 100, 120, 200, 240, 400, 480, 800, 960, 1600, 1920, 3200, and 3840 Sps (MCLK = 4.9152 MHz). To ease communication between the ADCs and a microcontroller, the converters include a simple three-wire serial interface which is SPI™ and Microwire™ compatible with a Schmitt-trigger input on the serial clock (SCLK). High dynamic range, programmable output rates, and flexible power supply options makes these ADCs ideal solutions for weigh scale and process control applications. ORDERING INFORMATION See page 47 VREF- VD+ DIFFERENTIAL 4TH ORDER ∆Σ MODULATOR PROGRAMMABLE SINC FIR FILTER CS AIN2+ SCLK (CS5534 SHOWN) AIN3- CLOCK GENERATOR LATCH AIN4+ AIN4- VA- http://www.cirrus.com SDO MUX AIN2AIN3+ SDI SERIAL INTERFACE A0/GUARD A1 OSC1 OSC2 Copyright © Cirrus Logic, Inc. 2008 (All Rights Reserved) CALIBRATION SRAM/CONTROL LOGIC DGND OCT ‘08 DS755F3 CS5532/34-BS TABLE OF CONTENTS 1. CHARACTERISTICS AND SPECIFICATIONS ..........................................................4 ANALOG CHARACTERISTICS..........................................................................4 TYPICAL RMS NOISE (NV) ...............................................................................7 TYPICAL NOISE-FREE RESOLUTION(BITS) ...................................................7 5 V DIGITAL CHARACTERISTICS ....................................................................8 3 V DIGITAL CHARACTERISTICS ....................................................................8 DYNAMIC CHARACTERISTICS ........................................................................9 ABSOLUTE MAXIMUM RATINGS .....................................................................9 SWITCHING CHARACTERISTICS ..................................................................10 2. GENERAL DESCRIPTION .......................................................................................12 2.1. Analog Input ....................................................................................................12 2.1.1. Analog Input Span .................................................................................... 13 2.1.2. Multiplexed Settling Limitations ............................................................13 2.1.3. Voltage Noise Density Performance .....................................................13 2.1.4. No Offset DAC ......................................................................................14 2.2. Overview of ADC Register Structure and Operating Modes ............................14 2.2.1. System Initialization ..............................................................................15 2.2.2. Serial Port Interface ..............................................................................22 2.2.3. Reading/Writing On-Chip Registers ......................................................23 2.3. Configuration Register .....................................................................................23 2.3.1. Power Consumption .............................................................................23 2.3.2. System Reset Sequence ......................................................................23 2.3.3. Input Short ............................................................................................24 2.3.4. Guard Signal .........................................................................................24 2.3.5. Voltage Reference Select .....................................................................24 2.3.6. Output Latch Pins .................................................................................24 2.3.7. Offset and Gain Select ..........................................................................25 2.3.8. Filter Rate Select ..................................................................................25 2.4. Setting up the CSRs for a Measurement .........................................................27 2.5. Calibration ........................................................................................................30 2.5.1. Calibration Registers ............................................................................30 2.5.2. Performing Calibrations ........................................................................31 2.5.3. Self Calibration .....................................................................................31 2.5.4. System Calibration ................................................................................32 2.5.5. Calibration Tips .....................................................................................32 2.5.6. Limitations in Calibration Range ...........................................................33 2.6. Performing Conversions ..................................................................................33 2.6.1. Single Conversion Mode .......................................................................33 2.6.2. Continuous Conversion Mode ..............................................................34 2.6.3. Examples of Using CSRs to Perform Conversions and Calibrations ....35 2.7. Using Multiple ADCs Synchronously ...............................................................36 2.8. Conversion Output Coding ..............................................................................36 2.9. Digital Filter ......................................................................................................38 2.10. Clock Generator ...............................................................................................39 2.11. Power Supply Arrangements ...........................................................................39 2.12. Getting Started ................................................................................................43 2.13. PCB Layout .....................................................................................................43 3. PIN DESCRIPTIONS ...............................................................................................44 4. SPECIFICATION DEFINITIONS ...............................................................................46 5. ORDERING INFORMATION .....................................................................................47 6. ENVIRONMENTAL, MANUFACTURING, & HANDLING INFORMATION ..............47 7. PACKAGE DRAWINGS ...........................................................................................48 2 DS755F3 CS5532/34-BS LIST OF FIGURES Figure 1. SDI Write Timing (Not to Scale)............................................................................... 11 Figure 2. SDO Read Timing (Not to Scale)............................................................................. 11 Figure 3. Multiplexer Configuration ......................................................................................... 12 Figure 4. Input models for AIN+ and AIN- pins ....................................................................... 13 Figure 5. Measured Voltage Noise Density............................................................................. 13 Figure 6. CS5532/34 Register Diagram .................................................................................. 14 Figure 7. Command and Data Word Timing ........................................................................... 22 Figure 8. Guard Signal Shielding Scheme .............................................................................. 24 Figure 9. Input Reference Model when VRS = 1 .................................................................... 25 Figure 10. Input Reference Model when VRS = 0 .................................................................. 25 Figure 11. Self Calibration of Offset ........................................................................................ 32 Figure 12. Self Calibration of Gain .......................................................................................... 32 Figure 13. System Calibration of Offset .................................................................................. 32 Figure 14. System Calibration of Gain .................................................................................... 32 Figure 15. Synchronizing Multiple ADCs................................................................................. 36 Figure 16. Digital Filter Response (WR = 60 Sps) .................................................................. 38 Figure 18. 120 Sps Filter Phase Plot to 120 Hz ...................................................................... 38 Figure 17. 120 Sps Filter Magnitude Plot to 120 Hz ............................................................... 38 Figure 19. Z-Transforms of Digital Filters................................................................................ 38 Figure 20. On-chip Oscillator Model........................................................................................ 39 Figure 21. CS5532 Configured with a Single +5 V Supply ..................................................... 40 Figure 22. CS5532 Configured with ±2.5 V Analog Supplies.................................................. 41 Figure 23. CS5532 Configured with ±3 V Analog Supplies..................................................... 41 Figure 24. CS5532 Configured for Thermocouple Measurement ........................................... 42 Figure 25. Bridge with Series Resistors .................................................................................. 42 LIST OF TABLES Table 1. Conversion Timing – Single Mode ............................................................................ 34 Table 2. Conversion Timing – Continuous Mode .................................................................... 35 Table 3. Command Byte Pointer ............................................................................................. 35 Table 4. Output Coding for 24-bit CS5532 and CS5534......................................................... 37 DS755F3 3 CS5532/34-BS 1. CHARACTERISTICS AND SPECIFICATIONS ANALOG CHARACTERISTICS (VA+, VD+ = 5 V ±5%; VREF+ = 5 V; VA-, VREF-, DGND = 0 V; MCLK = 4.9152 MHz; OWR (Output Word Rate) = 60 Sps; Bipolar Mode; Gain = 32) (See Notes 1 and 2.) Parameter Accuracy Linearity Error No Missing Codes Bipolar Offset Unipolar Offset Offset Drift Bipolar Full-scale Error Unipolar Full-scale Error Full-scale Drift (Notes 3 and 4) (Note 4) Min Typ Max Unit 24 - ±0.0007 ±16 ±0.0015 ±32 %FS Bits LSB24 - ±32 ±64 LSB24 - 640/G + 5 ±8 ±16 2 ±31 ±62 - nV/°C ppm ppm ppm/°C Notes: 1. Applies after system calibration at any temperature within -40 °C ~ +85 °C. 2. Specifications guaranteed by design, characterization, and/or test. LSB is 24 bits. 3. This specification applies to the device only and does not include any effects by external parasitic thermocouples. The PGIA contributes 5 nV of offset drift, and the modulator contributes 640/G nV of offset drift, where G is the amplifier gain setting. 4. Drift over specified temperature range after calibration at power-up at 25 °C. 4 DS755F3 CS5532/34-BS ANALOG CHARACTERISTICS (Continued) (See Notes 1 and 2.) Parameter Min Typ Analog Input Common Mode + Signal on AIN+ or AIN-Bipolar/Unipolar Mode Gain = 1 VAGain = 2, 4, 8, 16, 32, 64 (Note 5) VA- + 0.7 CVF Current on AIN+ or AINGain = 1 (Note 6, 7) 50 Gain = 2, 4, 8, 16, 32, 64 1200 Input Current Noise Gain = 1 200 Gain = 2, 4, 8, 16, 32, 64 1 Input Leakage for Mux when Off (at 25 °C) 10 Off-channel Mux Isolation 120 Open Circuit Detect Current 100 300 Common Mode Rejection dc, Gain = 1 90 dc, Gain = 64 130 50, 60 Hz 120 Input Capacitance 60 Guard Drive Output 20 Voltage Reference Input Range (VREF+) - (VREF-) 1 2.5 CVF Current (Note 6, 7) 50 Common Mode Rejection dc 120 50, 60 Hz 120 Input Capacitance 11 System Calibration Specifications Full-scale Calibration Range Bipolar/Unipolar Mode 3 Offset Calibration Range Bipolar Mode -100 Offset Calibration Range Unipolar Mode -90 - Max Unit VA+ VA+ - 1.7 - V V nA pA pA/√Hz pA/√Hz pA dB nA dB dB dB pF µA (VA+)-(VA-) 22 V nA dB dB pF 110 100 90 %FS %FS %FS Notes: 5. The voltage on the analog inputs is amplified by the PGIA, and becomes VCM ± Gain*(AIN+ - AIN-)/2 at the differential outputs of the amplifier. In addition to the input common mode + signal requirements for the analog input pins, the differential outputs of the amplifier must remain between (VA- + 0.1 V) and (VA+ - 0.1 V) to avoid saturation of the output stage. 6. See the section of the data sheet which discusses input models. 7. Input current on AIN+ or AIN- (with Gain = 1), or VREF+ or VREF- may increase to 250 nA if operated within 50 mV of VA+ or VA-. This is due to the rough charge buffer being saturated under these conditions. DS755F3 5 CS5532/34-BS ANALOG CHARACTERISTICS (Continued) (See Notes 1 and 2.) Parameter Min Typ Max Unit - 13 0.5 15 1 mA mA - 70 4 500 80 - mW mW µW - 115 115 - dB dB Power Supplies DC Power Supply Currents (Normal Mode) Power Consumption IA+, IAID+ Normal Mode Standby Sleep Power Supply Rejection (Notes 8 and 9) (Note 10) dc Positive Supplies dc Negative Supply 8. All outputs unloaded. All input CMOS levels. 9. Power is specified when the instrumentation amplifier (Gain ≥ 2) is on. Analog supply current is reduced by approximately 1/2 when the instrumentation amplifier is off (Gain = 1). 10. Tested with 100 mV change on VA+ or VA-. 6 DS755F3 CS5532/34-BS TYPICAL RMS NOISE (nV) (See notes 11, 12, 13 and 14) Output Word -3 dB Filter Rate (Sps) Frequency (Hz) 7.5 1.94 15 3.88 30 7.75 60 15.5 120 31 240 62 480 122 960 230 1,920 390 3,840 780 Notes: 11. 12. 13. 14. x64 8.5 12 17 24 34 80 113 159 260 1360 x32 9 13 18 25 36 136 194 274 470 2690 Instrumentation Amplifier Gain x16 x8 x4 10 15 26 15 21 37 21 30 52 29 42 73 42 59 103 260 514 1020 369 730 1450 523 1030 2060 912 1810 3620 5380 10800 21500 x2 50 70 99 140 198 2050 2900 4110 7230 43000 x1 99 139 196 277 392 4090 5810 8230 14500 86000 The -B devices provide the best noise specifications. Wideband noise aliased into the baseband. Referred to the input. Typical values shown for 25 °C. For Peak-to-Peak Noise multiply by 6.6 for all ranges and output rates. Word rates and -3dB points with FRS = 0. When FRS = 1, word rates and -3dB points scale by 5/6. TYPICAL NOISE-FREE RESOLUTION(BITS) (See Notes 15 and 16) Output Word -3 dB Filter Rate (Sps) Frequency (Hz) 7.5 1.94 15 3.88 30 7.75 60 15.5 120 31 240 62 480 122 960 230 1,920 390 3,840 780 x64 20 20 19 19 18 17 17 16 16 13 x32 21 21 20 20 19 17 17 16 16 13 Instrumentation Amplifier Gain x16 x8 x4 22 23 23 22 22 22 21 22 22 21 21 21 20 21 21 18 18 18 17 17 17 17 17 17 16 16 16 13 13 13 x2 23 22 22 21 21 18 17 17 16 13 x1 23 22 22 21 21 18 17 17 16 13 15. Noise-free resolution listed is for bipolar operation, and is calculated as LOG((Input Span)/(6.6xRMS Noise))/LOG(2) rounded to the nearest bit. For unipolar operation, the input span is 1/2 as large, so one bit is lost. The input span is calculated in the analog input span section of the data sheet. The noise-free resolution table is computed with a value of 1.0 in the gain register. Values other than 1.0 will scale the noise, and change the noise-free resolution accordingly. 16. “Noise-free resolution” is not the same as “effective resolution”. Effective resolution is based on the RMS noise value, while noise-free resolution is based on a peak-to-peak noise value specified as 6.6 times the RMS noise value. Effective resolution is calculated as LOG((Input Span)/(RMS Noise))/LOG(2). Specifications are subject to change without notice. DS755F3 7 CS5532/34-BS 5 V DIGITAL CHARACTERISTICS (VA+, VD+ = 5 V ±5%; VA-, DGND = 0 V; See Notes 2 and 17.) Parameter Symbol Min Typ Max Unit High-level Input Voltage All Pins Except SCLK SCLK VIH 0.6 VD+ (VD+) - 0.45 - VD+ VD+ V Low-level Input Voltage All Pins Except SCLK SCLK VIL 0.0 0.0 - 0.8 0.6 V High-level Output Voltage A0 and A1, Iout = -1.0 mA SDO, Iout = -5.0 mA VOH (VA+) - 1.0 (VD+) - 1.0 - - V Low-level Output Voltage A0 and A1, Iout = 1.0 mA SDO, Iout = 5.0 mA VOL - - (VA-) + 0.4 0.4 V Input Leakage Current Iin - ±1 ±10 µA SDO Tri-State Leakage Current IOZ - - ±10 µA Digital Output Pin Capacitance Cout - 9 - pF 3 V DIGITAL CHARACTERISTICS (TA = 25 °C; VA+ = 5V ±5%; VD+ = 3.0V±10%; VA-, DGND = 0V; See Notes 2 and 17.) Parameter Symbol Min Typ Max Unit High-level Input Voltage All Pins Except SCLK SCLK VIH 0.6 VD+ (VD+) - 0.45 - VD+ VD+ V Low-level Input Voltage All Pins Except SCLK SCLK VIL 0.0 0.0 - 0.8 0.6 V High-level Output Voltage A0 and A1, Iout = -1.0 mA SDO, Iout = -5.0 mA VOH (VA+) - 1.0 (VD+) - 1.0 - - V Low-level Output Voltage A0 and A1, Iout = 1.0 mA SDO, Iout = 5.0 mA VOL - - (VA-) + 0.4 0.4 V Input Leakage Current Iin - ±1 ±10 µA SDO Tri-State Leakage Current IOZ - - ±10 µA Digital Output Pin Capacitance Cout - 9 - pF 17. All measurements performed under static conditions. 8 DS755F3 CS5532/34-BS DYNAMIC CHARACTERISTICS Parameter Symbol Ratio Unit Modulator Sampling Rate fs MCLK/16 Sps Filter Settling Time to 1/2 LSB (Full Scale Step Input) Single Conversion mode (Notes 18, 19, and 20) Continuous Conversion mode, OWR < 3200 Sps Continuous Conversion mode, OWR ≥ 3200 Sps ts ts ts 1/OWRSC 5/OWRsinc5 + 3/OWR 5/OWR s s s 18. The ADCs use a Sinc5 filter for the 3200 Sps and 3840 Sps output word rate (OWR) and a Sinc5 filter followed by a Sinc3 filter for the other OWRs. OWRsinc5 refers to the 3200 Sps (FRS = 1) or 3840 Sps (FRS = 0) word rate associated with the Sinc5 filter. 19. The single conversion mode only outputs fully settled conversions. See Table 1 for more details about single conversion mode timing. OWRSC is used here to designate the different conversion time associated with single conversions. 20. The continuous conversion mode outputs every conversion. This means that the filter’s settling time with a full scale step input in the continuous conversion mode is dictated by the OWR. ABSOLUTE MAXIMUM RATINGS (DGND = 0 V; See Note 21.) Parameter Symbol Min Typ Max Unit (Notes 22 and 23) Positive Digital Positive Analog Negative Analog VD+ VA+ VA- -0.3 -0.3 +0.3 - +6.0 +6.0 -3.75 V V V (Notes 24 and 25) IIN - - ±10 mA IOUT - - ±25 mA (Note 26) PDN - - 500 mW VREF pins AIN Pins VINR VINA (VA-) -0.3 (VA-) -0.3 - (VA+) + 0.3 (VA+) + 0.3 V V VIND -0.3 - (VD+) + 0.3 V Ambient Operating Temperature TA -40 - 85 °C Storage Temperature Tstg -65 - 150 °C DC Power Supplies Input Current, Any Pin Except Supplies Output Current Power Dissipation Analog Input Voltage Digital Input Voltage Notes: 21. 22. 23. 24. 25. All voltages with respect to ground. VA+ and VA- must satisfy {(VA+) - (VA-)} ≤ +6.6 V. VD+ and VA- must satisfy {(VD+) - (VA-)} ≤ +7.5 V. Applies to all pins including continuous overvoltage conditions at the analog input (AIN) pins. Transient current of up to 100 mA will not cause SCR latch-up. Maximum input current for a power supply pin is ±50 mA. 26. Total power dissipation, including all input currents and output currents. WARNING: Operation at or beyond these limits may result in permanent damage to the device. Normal operation is not guaranteed at these extremes. DS755F3 9 CS5532/34-BS SWITCHING CHARACTERISTICS (VA+ = 2.5 V or 5 V ±5%; VA- = -2.5V±5% or 0 V; VD+ = 3.0 V ±10% or 5 V ±5%;DGND = 0 V; Levels: Logic 0 = 0 V, Logic 1 = VD+; CL = 50 pF; See Figures 1 and 2.) Parameter Min Typ Max Unit 1 4.9152 5 MHz 40 - 60 % - 50 1.0 100 - µs µs ns - 50 1.0 100 - µs µs ns tost - 20 - ms SCLK 0 - 2 MHz t1 t2 250 250 - - ns ns CS Enable to Valid Latch Clock t3 50 - - ns Data Set-up Time prior to SCLK rising t4 50 - - ns Data Hold Time After SCLK Rising t5 100 - - ns SCLK Falling Prior to CS Disable t6 100 - - ns CS to Data Valid t7 - - 150 ns SCLK Falling to New Data Bit t8 - - 150 ns CS Rising to SDO Hi-Z t9 - - 150 ns Master Clock Frequency Symbol (Note 27) External Clock or Crystal Oscillator MCLK Master Clock Duty Cycle Rise Times Fall Times (Note 28) Any Digital Input Except SCLK SCLK Any Digital Output trise (Note 28) Any Digital Input Except SCLK SCLK Any Digital Output tfall Start-up Oscillator Start-up Time XTAL = 4.9152 MHz (Note 29) Serial Port Timing Serial Clock Frequency Serial Clock Pulse Width High Pulse Width Low SDI Write Timing SDO Read Timing Notes: 27. Device parameters are specified with a 4.9152 MHz clock. 28. Specified using 10% and 90% points on waveform of interest. Output loaded with 50 pF. 29. Oscillator start-up time varies with crystal parameters. This specification does not apply when using an external clock source. 10 DS755F3 CS5532/34-BS CS t3 SDI M SB M S B -1 t4 LSB t5 t1 t6 SC LK t2 Figure 1. SDI Write Timing (Not to Scale) CS t7 SDO t9 MSB M S B -1 LS B t2 t8 SC LK t1 Figure 2. SDO Read Timing (Not to Scale) DS755F3 11 CS5532/34-BS 2. GENERAL DESCRIPTION The CS5532/34 are highly integrated ∆Σ Analogto-Digital Converters (ADCs) which use chargebalance techniques to achieve 24-bit performance. The ADCs are optimized for measuring low-level unipolar or bipolar signals in weigh scale, process control, scientific, and medical applications. To accommodate these applications, the ADCs come as either two-channel (CS5532) or four-channel (CS5534) devices and include a very-lownoise, chopper-stabilized, programmable-gain instrumentation amplifier (PGIA, 6 nV/√Hz @ 0.1 Hz) with selectable gains of 1×, 2×, 4×, 8×, 16×, 32×, and 64×. These ADCs also include a fourth-order ∆Σ modulator followed by a digital filter which provides twenty selectable output word rates of 6.25, 7.5, 12.5, 15, 25, 30, 50, 60, 100, 120, 200, 240, 400, 480, 800, 960, 1600, 1920, 3200, and 3840 Samples per second (MCLK = 4.9152 MHz). To ease communication between the ADCs and a microcontroller, the converters include a simple three-wire serial interface which is SPI and Mi- AIN2+ AIN2AIN1+ AIN1- CS5531/32 IN+ M U INX M U X XGAIN The instrumentation amplifier is chopper stabilized and operates with a chop-clock frequency of MCLK/128. The CVF (sampling) current into the VREF+ VREF- X1 X1 C1 PIN C2 PIN 22 nF X1 Differential 4 th Order ∆Σ Modulator 1000 Ω IN+ IN- The unity gain buffer is designed to accommodate rail-to-rail input signals. The common mode plus signal range for the unity gain buffer amplifier is VA- to VA+. Typical CVF (sampling) current for the unity gain buffer amplifier is about 50 nA (MCLK = 4.9152 MHz, see Figure 4). 1000 Ω IN- CS5533/34 2.1. Analog Input Figure 3 illustrates a block diagram of the CS5532/34. The front end consists of a multiplexer, a unity gain coarse/fine charge input buffer, and a programmable-gain, chopper-stabilized instrumentation amplifier. The unity gain buffer is activated any time conversions are performed with a gain of one and the instrumentation amplifier is activated any time conversions are performed with gain settings greater than one. X1 X1 IN+ AIN4+ AIN4* * * AIN1+ AIN1- crowire compatible with a Schmitt-trigger input on the serial clock (SCLK). 5 Sinc Digital Filter Programmable Sinc3 Digital Filter Serial Port X1 GAIN is the gain setting of the PGIA (i.e. 2, 4, 8, 16, 32, 64) Figure 3. Multiplexer Configuration 12 DS755F3 CS5532/34-BS instrumentation amplifier is typically 1200 pA over -40°C to +85°C (MCLK=4.9152 MHz). The common-mode plus signal range of the instrumentation amplifier is (VA-) + 0.7 V to (VA+) 1.7 V. Figure 4 illustrates the input models for the amplifiers. The dynamic input current for each of the pins can be determined from the models shown. Gain = 2, 4, 8, 16, 32, 64 AIN C = 3 .9 pF Vos ≤ 8 mV in = fVos C f= MCLK 128 Gain = 1 φ1 Fine φ1 Coarse AIN C = 14 pF Vos ≤ 12 mV in = fVos C f = MCLK 16 Figure 4. Input models for AIN+ and AIN- pins Note: The C=3.9pF and C = 14pF capacitors are for input current modeling only. For physical input capacitance see ‘Input Capacitance’ specification under Analog Characteristics. 2.1.1. Analog Input Span The full-scale input signal that the converter can digitize is a function of the gain setting and the reference voltage connected between the VREF+ and VREF- pins. The full-scale input span of the converter is ((VREF+) - (VREF-))/(GxA), where G is the gain of the amplifier and A is 2 for VRS = 0, or A is 1 for VRS = 1. VRS is the Voltage Reference DS755F3 Select bit, and must be set according to the differential voltage applied to the VREF+ and VREF- pins on the part. See section 2.3.5 for more details. After reset, the unity gain buffer is engaged. With a 2.5 V reference this would make the full-scale input range default to 2.5 V. By activating the instrumentation amplifier (i.e. a gain setting other than 1) and using a gain setting of 32, the full-scale input range can quickly be set to 2.5/32 or about 78 mV. Note that these input ranges assume the calibration registers are set to their default values (i.e. Gain = 1.0 and Offset = 0.0). 2.1.2. Multiplexed Settling Limitations The settling performance of the CS5532/34 in multiplexed applications is affected by the single-pole, low-pass filter which follows the instrumentation amplifier (see Figure 3). To achieve data sheet settling and linearity specifications, it is recommended that a 22 nF C0G capacitor be used. Capacitors as low as 10 nF or X7R type capacitors can also be used with some minor increase in distortion for AC signals. 2.1.3. Voltage Noise Density Performance Figure 5 illustrates the measured voltage noise density versus frequency from 0.025 Hz to 10 Hz of a CS5532-BS. The device was powered with ±2.5 V supplies, using 30 Sps OWR, the 64x gain range, bipolar mode, and with the input short bit enabled. 1000 100 10 1 0.025 0.10 1.00 Frequency (Hz) 10.00 Figure 5. Measured Voltage Noise Density, 64x 13 CS5532/34-BS An offset DAC was not included in the CS553X family because the high dynamic range of the converter eliminates the need for one. The offset register can be manipulated by the user to mimic the function of a DAC if desired. 2.2. Overview of ADC Register Structure and Operating Modes The CS5532/34 ADCs have an on-chip controller, which includes a number of user-accessible registers. The registers are used to hold offset and gain calibration results, configure the chip's operating modes, hold conversion instructions, and to store conversion data words. Figure 6 depicts a block diagram of the on-chip controller’s internal registers. Each of the converters has 32-bit registers to function as offset and gain calibration registers for each channel. The CS5532 has two offset and two gain calibration registers, the CS5534 has four offset and four gain calibration registers. These registers Offset Registers (4 x 32) Gain Registers (4 x 32) hold calibration results. The contents of these registers can be read or written by the user. This allows calibration data to be off-loaded into an external EEPROM. The user can also manipulate the contents of these registers to modify the offset or the gain slope of the converter. The converters include a 32-bit configuration register which is used for setting options such as the power down modes, resetting the converter, shorting the analog inputs, and enabling diagnostic test bits like the guard signal. A group of registers, called Channel Setup Registers, are used to hold pre-loaded conversion instructions. Each channel setup register is 32 bits wide, and holds two 16-bit conversion instructions referred to as Setups. Upon power up, these registers can be initialized by the system microcontroller with conversion instructions. The user can then instruct the converter to perform single or multiple Channel Setup Registers (4 x 32) Offset 1 (1 x 32) Gain 1 (1 x 32) Setup 1 (1 x 16) Setup 2 (1 x 16) Offset 2 (1 x 32) Gain 2 (1 x 32) Setup 3 (1 x 16) Setup 4 (1 x 16) Offset 3 (1 x 32) Gain 3 (1 x 32) Setup 5 (1 x 16) Setup 6 (1 x 16) Offset 4 (1 x 32) Gain 4 (1 x 32) Setup 7 (1 x 16) Setup 8 (1 x 16) Conversion Data Register (1 x 32) Data (1 x 32) Read Only 2.1.4. No Offset DAC Configuration Register (1 x 32) Power Save Select Reset System Input Short Guard Signal Voltage Reference Select Output Latch Output Latch Select Offset/Gain Select Filter Rate Select CS SDI SDO SCLK W rite Only Serial Interface Channel Select Gain W ord Rate Unipolar/Bipolar Output Latch Delay Time Open Circuit Detect Offset/Gain Pointer Com mand Register (1 × 8) Figure 6. CS5532/34 Register Diagram 14 DS755F3 CS5532/34-BS conversions or calibrations with the converter in the mode defined by one of these Setups. Using the single conversion mode, an 8-bit command word can be written into the serial port. The command includes pointer bits which ‘point’ to a 16-bit command in one of the Channel Setup Registers which is to be executed. The 16-bit Setups can be programmed to perform a conversion on any of the input channels of the converter. More than one of the 16-bit Setups can be used for the same analog input channel. This allows the user to convert on the same signal with either a different conversion speed, a different gain range, or any of the other options available in the channel setup registers. Alternately, the user can set up the registers to perform different conversion conditions on each of the input channels. The ADCs also include continuous conversion capability. The ADCs can be instructed to continuously convert, referencing one 16-bit command Setup. In the continuous conversions mode, the conversion data words are loaded into a shift register. The converter issues a flag on the SDO pin when a conversion cycle is completed so the user can read the register, if need be. See “Performing Conversions” on page 33 for more details. The following pages document how to initialize the converter, perform offset and gain calibrations, and how to configure the converter for the various conversion modes. Each of the bits of the configuration register and of the Channel Setup Registers is described. A list of examples follows the description section. Also the Command Register Quick Reference can be used to decode all valid commands (the first 8 bits into the serial port). 2.2.1. System Initialization The CS5532/34 provide no power-on-reset function. To initialize the ADCs, the user must perform a software reset by resetting the ADC’s serial port with the Serial Port Initialization sequence. This sequence resets the serial port to the command mode DS755F3 and is accomplished by transmitting at least 15 SYNC1 command bytes (0xFF hexadecimal), followed by one SYNC0 command (0xFE hexadecimal). Note that this sequence can be initiated at anytime to reinitialize the serial port. To complete the system initialization sequence, the user must also perform a system reset sequence which is as follows: Write a logic 1 into the RS bit of the configuration register. This will reset the calibration registers and other logic (but not the serial port). A valid reset will set the RV bit in the configuration register to a logic 1. After writing the RS bit to a logic 1, wait 20 microseconds, then write the RS bit back to logic 0. While this involves writing an entire word into the configuration register, the RV bit is a read-only bit, therefore a write to the configuration register will not overwrite the RV bit. After clearing the RS bit back to logic 0, read the configuration register to check the state of the RV bit as this indicates that a valid reset occurred. Reading the configuration register clears the RV bit back to logic 0. Completing the reset cycle initializes the on-chip registers to the following states: Configuration Register: Offset Registers: Gain Registers: Channel Setup Registers: Note: 00000000(H) 00000000(H) 01000000(H) 00000000(H) Previous datasheets stated that the RS bit would clear itself back to logic 0 and therefore the user was not required to write the RS bit back to logic 0. The current data sheet instruction that requires the user to write into the configuration register to clear the RS bit has been added to insure that the RS bit is cleared. Characterization across multiple lots of silicon has indicated some chips do not automatically reset the RS bit to logic 0 in the configuration register, although the reset function is completed. This occurs only on small number of chips when the VA- supply is negative with respect to DGND. This has not caused an operational issue for customers because their start-up sequence includes 15 CS5532/34-BS writing a word (with RS=0) into the configuration register after performing a reset. The change in the reset sequence to include writing the RS bit back to 0 insures the clearing of the RS bit in the event that a user does not write into the configuration register after the RS bit has been set. The RV bit in the Configuration Register is set to indicate a valid reset has occurred. The RS bit should be written back to logic 0 to complete the reset cycle. After a system initialization or reset, the 16 on-chip controller is initialized into command mode where it waits for a valid command (the first 8 bits written into the serial port are shifted into the command register). Once a valid command is received and decoded, the byte instructs the converter to either acquire data from or transfer data to an internal register(s), or perform a conversion or a calibration. The Command Register Descriptions section can be used to decode all valid commands. DS755F3 CS5532/34-BS 2.2.2. Command Register Quick Reference D7(MSB) D6 D5 D4 D3 D2 D1 D0 0 ARA CS1 CS0 R/W RSB2 RSB1 RSB0 BIT NAME D7 Command Bit, C VALUE FUNCTION 0 1 Must be logic 0 for these commands. These commands are invalid if this bit is logic 1. D6 Access Registers as Arrays, ARA 0 1 Ignore this function. Access the respective registers, offset, gain, or channel-setup, as an array of registers. The particular registers accessed are determined by the RS bits. The registers are accessed MSB first with physical channel 0 accessed first followed by physical channel 1 next and so forth. D5-D4 Channel Select Bits, CS1-CS0 00 01 10 11 CS1-CS0 provide the address of one of the two (four for CS5534) physical input channels. These bits are also used to access the calibration registers associated with the respective physical input channel. Note that these bits are ignored when reading data register. D3 Read/Write, R/W 0 1 Write to selected register. Read from selected register. D2-D0 Register Select Bit, RSB3-RSB0 000 001 010 011 101 110 111 Reserved Offset Register Gain Register Configuration Register Channel-Setup Registers Reserved Reserved D7(MSB) D6 D5 D4 D3 D2 D1 D0 1 MC CSRP2 CSRP1 CSRP0 CC2 CC1 CC0 BIT NAME D7 Command Bit, C 0 1 These commands are invalid if this bit is logic 0. Must be logic 1 for these commands. D6 Multiple Conversions, MC 0 1 Perform fully settled single conversions. Perform conversions continuously. D5-D3 Channel-Setup Register Pointer Bits, CSRP 000 ... 111 These bits are used as pointers to the channel-setup registers. Either a single conversion or continuous conversions are performed on the channel setup register pointed to by these bits. D2-D0 Conversion/Calibration Bits, CC2-CC0 000 001 010 011 100 101 110 111 Normal Conversion Self-Offset Calibration Self-Gain Calibration Reserved Reserved System-Offset Calibration System-Gain Calibration Reserved DS755F3 VALUE FUNCTION 17 CS5532/34-BS 2.2.3. Command Register Descriptions READ/WRITE ALL OFFSET CALIBRATION REGISTERS D7(MSB) 0 Function: D6 1 D5 0 D4 0 D3 R/W D2 0 D1 0 D0 1 D1 1 D0 0 D1 0 D0 1 These commands are used to access the offset registers as arrays. R/W (Read/Write) 0 Write to selected registers. 1 Read from selected registers. READ/WRITE ALL GAIN CALIBRATION REGISTERS D7(MSB) 0 Function: D6 1 D5 0 D4 0 D3 R/W D2 0 These commands are used to access the gain registers as arrays. R/W (Read/Write) 0 Write to selected registers. 1 Read from selected registers. READ/WRITE ALL CHANNEL-SETUP REGISTERS D7(MSB) 0 Function: D6 1 D5 0 D4 0 D3 R/W D2 1 These commands are used to access the channel-setup registers as arrays. R/W (Read/Write) 0 Write to selected registers. 1 Read from selected registers. READ/WRITE INDIVIDUAL OFFSET REGISTER D7(MSB) 0 Function: D6 0 D5 CS1 D4 CS0 D3 R/W D2 0 D1 0 D0 1 These commands are used to access each offset register separately. CS1 - CS0 decode the registers accessed. R/W (Read/Write) 0 Write to selected register. 1 Read from selected register. CS[1:0] (Channel Select Bits) 00 18 Offset Register 1 01 Offset Register 2 10 Offset Register 3 (CS5534 only) 11 Offset Register 4 (CS5534 only) DS755F3 CS5532/34-BS READ/WRITE INDIVIDUAL GAIN REGISTER D7(MSB) 0 Function: D6 0 D5 CS1 D4 CS0 D3 R/W D2 0 D1 1 D0 0 These commands are used to access each gain register separately. CS1 - CS0 decode the registers accessed. R/W (Read/Write) 0 Write to selected register. 1 Read from selected register. CS[1:0] (Channel Select Bits) 00 Gain Register 1 01 Gain Register 2 10 Gain Register 3 (CS5534 only) 11 Gain Register 4 (CS5534 only) READ/WRITE INDIVIDUAL CHANNEL-SETUP REGISTER D7(MSB) 0 Function: D6 0 D5 CS1 D4 CS0 D3 R/W D2 1 D1 0 D0 1 These commands are used to access each channel-setup register separately. CS1 - CS0 decode the registers accessed. R/W (Read/Write) 0 Write to selected register. 1 Read from selected register. CS[1:0] (Channel Select Bits) 00 Channel-Setup Register 1 01 Channel-Setup Register 2 10 Channel-Setup Register 3 11 Channel-Setup Register 4 READ/WRITE CONFIGURATION REGISTER D7(MSB) 0 Function: D6 0 D5 0 D4 0 D3 R/W D2 0 D1 1 D0 1 These commands are used to read from or write to the configuration register. R/W (Read/Write) DS755F3 0 Write to selected register. 1 Read from selected register. 19 CS5532/34-BS PERFORM CONVERSION D7(MSB) 1 Function: D6 MC D5 CSRP2 D4 CSRP1 D3 CSRP0 D2 0 D1 0 D0 0 These commands instruct the ADC to perform either a single, fully-settled conversion or continuous conversions on the physical input channel pointed to by the pointer bits (CSRP2 CRSP0) in the channel-setup register. MC (Multiple Conversions) 0 Perform a single conversion. 1 Perform continuous conversions. CSRP [2:0] (Channel Setup Register Pointer Bits) 20 000 Setup 1 001 Setup 2 010 Setup 3 011 Setup 4 100 Setup 5 101 Setup 6 110 Setup 7 111 Setup 8 DS755F3 CS5532/34-BS PERFORM CALIBRATION D7(MSB) 1 Function: D6 0 D5 CSRP2 D4 CSRP1 D3 CSRP0 D2 CC2 D1 CC1 D0 CC0 These commands instruct the ADC to perform a calibration on the physical input channel selected by the setup register which is chosen by the command byte pointer bits (CSRP2 CSRP0). CSRP [2:0] (Channel Setup Register Pointer Bits) 000 Setup 1 001 Setup 2 010 Setup 3 011 Setup 4 100 Setup 5 101 Setup 6 110 Setup 7 111 Setup 8 CC [2:0] (Calibration Control Bits) 000 Reserved 001 Self-Offset Calibration 010 Self-Gain Calibration 011 Reserved 100 Reserved 101 System-Offset Calibration 110 System-Gain Calibration 111 Reserved SYNC1 D7(MSB) 1 Function: D6 1 D5 1 D4 1 D3 1 D2 1 D1 1 D0 1 D2 1 D1 1 D0 0 D2 0 D1 0 D0 0 Part of the serial port re-initialization sequence. SYNC0 D7(MSB) 1 Function: D6 1 D5 1 D4 1 D3 1 End of the serial port re-initialization sequence. NULL D7(MSB) 0 Function: DS755F3 D6 0 D5 0 D4 0 D3 0 This command is used to clear a port flag and keep the converter in the continuous conversion mode. 21 CS5532/34-BS 2.2.4. Serial Port Interface The CS5532/34’s serial interface consists of four control lines: CS, SDI, SDO, SCLK. Figure 7 details the command and data word timing. CS, Chip Select, is the control line which enables access to the serial port. If the CS pin is tied low, the port can function as a three wire interface. SDI, Serial Data In, is the data signal used to transfer data to the converters. SDO, Serial Data Out, is the data signal used to transfer output data from the converters. The SDO output will be held at high impedance any time CS is at logic 1. SCLK, Serial Clock, is the serial bit-clock which controls the shifting of data to or from the ADC’s serial port. The CS pin must be held low (logic 0) before SCLK transitions can be recognized by the port logic. To accommodate optoisolators SCLK is designed with a Schmitt-trigger input to allow an optoisolator with slower rise and fall times to directly drive the pin. Additionally, SDO is capable of sinking or sourcing up to 5 mA to directly drive an optoisolator LED. SDO will have less than a 400 mV loss in the drive voltage when sinking or sourcing 5 mA. CS SCLK SDI LSB MSB Command Time 8 SCLKs Data Time 32 SCLKs Write Cycle CS SCLK SDI Command Time 8 SCLKs SDO LSB MSB Data Time 32 SCLKs Read Cycle CS SCLK SDI Command Time 8 SCLKs SDO MCLK /OWR Clock Cycles td* 8 SCLKs Clear SDO Flag Data Conversion Cycle MSB LSB Data Time 32 SCLKs * td is the time it takes the ADC to perform a conversion. See the Single Conversion and Continuous Conversion sections of the data sheet for more details about conversion timing. Figure 7. Command and Data Word Timing 22 DS755F3 CS5532/34-BS 2.2.5. Reading/Writing On-Chip Registers 2.3.1. Power Consumption The CS5532/34’s offset, gain, configuration, and channel-setup registers are readable and writable while the conversion data register is read only. The CS5532/34 accommodate three power consumption modes: normal, standby, and sleep. The default mode, “normal mode”, is entered after power is applied. In this mode, the CS5532/34-BS devices typically consume 70 mW. The other two modes are referred to as the power save modes. They power down most of the analog portion of the chip and stop filter convolutions. The power save modes are entered whenever the power down (PDW) bit of the configuration register is set to logic 1. The particular power save mode entered depends on state of the PSS (Power Save Select) bit. If PSS is logic 0, the converter enters the standby mode reducing the power consumption to 4 mW. The standby mode leaves the oscillator and the onchip bias generator for the analog portion of the chip active. This allows the converter to quickly return to the normal mode once PDW is set back to a logic 1. If PSS and PDW are both set to logic 1, the sleep mode is entered reducing the consumed power to around 500 µW. Since this sleep mode disables the oscillator, approximately a 20 ms oscillator start-up delay period is required before returning to the normal mode. If an external clock is used, there will be no delay. Further note that when the chips are used in the Gain = 1 mode, the PGIA is powered down. With the PGIA powered down, the power consumed in the normal power mode is reduced by approximately 1/2. Power consumption in the sleep and standby modes is not affected by the amplifier setting. As shown in Figure 7, to write to a particular register the user must transmit the appropriate write command and then follow that command by 32 bits of data. For example, to write 0x80000000 (hexadecimal) to physical channel one’s gain register, the user would first transmit the command byte 0x02 (hexadecimal) followed by the data 0x80000000 (hexadecimal). Similarly, to read a particular register the user must transmit the appropriate read command and then acquire the 32 bits of data. Once a register is written to or read from, the serial port returns to the command mode. In addition to accessing the internal registers one at a time, the gain and offset registers as well as the channel setup registers can be accessed as arrays (i.e. the entire register set can be accessed with one command). In the CS5532, there are two gain and offset registers, and in the CS5534, there are four gain and offset registers. There are four channel setup registers in both devices. As an example, to write 0x80000000 (hexadecimal) to all four gain registers in the CS5534, the user would transmit the command 0x42 (hexadecimal) followed by four iterations of 0x80000000 (hexadecimal), (i.e. 0x42 followed by 0x80000000, 0x80000000, 0x80000000, 0x80000000). The registers are written to or read from in sequential order (i.e, 1, followed by 2, 3, and 4). Once the registers are written to or read from, the serial port returns to the command mode. 2.3. Configuration Register To ease the architectural design and simplify the serial interface, the configuration register is thirtytwo bits long, however, only eleven of the thirtytwo bits are used. The following sections detail the bits in the configuration register. DS755F3 2.3.2. System Reset Sequence The reset system (RS) bit permits the user to perform a system reset. A system reset can be initiated at any time by writing a logic 1 to the RS bit in the configuration register. After the RS bit has been set, the internal logic of the chip will be initialized to a reset state. The reset valid (RV) bit is set indicating that the internal logic was properly reset. The RV bit is cleared after the configuration regis- 23 CS5532/34-BS ter is read. The on-chip registers are initialized to the following default states: Configuration Register: Offset Registers: Gain Registers: Channel Setup Registers: 00000000(H) 00000000(H) 01000000(H) 00000000(H) After reset, the RS bit should be written back to logic 0 to complete the reset cycle. The ADC will return to the command mode where it waits for a valid command. Also, the RS bit is the only bit in the configuration register that can be set when initiating a reset (i.e. a second write command is needed to set other bits in the Configuration Register after the RS bit has been cleared). 2.3.3. Input Short The input short bit allows the user to internally ground all the inputs of the multiplexer. This is a useful function because it allows the user to easily test the grounded input performance of the ADC and eliminate the noise effects due to the external system components. 2.3.4. Guard Signal The guard signal bit modifies the function of A0. When set, this bit outputs the common mode voltage of the instrumentation amplifier on A0. This feature is useful when the user wants to connect an external shield to the common mode potential of the instrumentation amplifier to protect against leakage. Figure 8 illustrates a typical connection diagram for the guard signal. buffer which reduces the dynamic current demand of the external reference. The reference’s input buffer is designed to accommodate rail-to-rail (common-mode plus signal) input voltages. The differential voltage between the VREF+ and VREF- can be any voltage from 1.0 V up to the analog supply (depending on how VRS is configured), however, the VREF+ cannot go above VA+ and the VREF- pin can not go below VA-. Note that the power supplies to the chip should be established before the reference voltage. 2.3.6. Output Latch Pins The A1-A0 pins of the ADCs mimic the D21D20/D5-D4 bits of the channel-setup registers if the output latch select (OLS) bit is logic 0 (default). If the OLS bit is logic 1, A1-A0 mimic the output latch bit settings in the configuration register. These two options give the user a choice of allowing the latch outputs to change anytime a different CSR is selected for a conversion, or to allow the latch bits to remain latched to a fixed state (determined by the configuration register bit) for all CSR selections. In either case, A1-A0 can be used to control external multiplexers and other logic functions outside the converter. The A1-A0 outputs can sink or source at least 1 mA, but it is recommended to limit drive currents to less than 20 µA to reduce self-heating of the chip. These outputs are powered C S 5 5 3 1 /3 2 /3 3 /3 4 A 0 /G U A R D +5 V A + A IN + 2.3.5. Voltage Reference Select The voltage reference select (VRS) bit selects the size of the sampling capacitor used to sample the voltage reference. The bit should be set based upon the magnitude of the reference voltage to achieve optimal performance. Figures 9 and 10 model the effects on the reference’s input impedance and input current for each VRS setting. As the models show, the reference includes a coarse/fine charge 24 out p V IN + c e n te r C o m m o n M o d e = 2 .5 V x1 V IN - A IN - out m Figure 8. Guard Signal Shielding Scheme DS755F3 CS5532/34-BS φ1 Fine φ1 Fine φ2 Coarse VREF C = 14pF Vos ≤ 8 mV in = fVos C MCLK 16 VRS = 1; 1 V ≤ VREF ≤ 2.5 V f= Figure 9. Input Reference Model when VRS = 1 from VA+ and VA-. Their output voltage will be limited to the VA+ voltage for a logic 1 and VAfor a logic 0. 2.3.7. Offset and Gain Select The Offset and Gain Select bit (OGS) is used to select the source of the calibration registers to use when performing conversions and calibrations. When the OGS bit is set to ‘0’, the offset and gain registers corresponding to the desired physical channel (CS1-CS0 in the selected Setup) will be accessed. When the OGS bit is set to ‘1’, the offset and gain registers pointed to by the OG1-OG0 bits in the selected Setup will be accessed. This feature allows multiple calibration values (e.g. for different gain settings) to be used on a single physical channel without having to re-calibrate or manipulate the calibration registers. DS755F3 φ2 Coarse VREF C = 7 pF Vos ≤ 16 mV i n = fV os C MCLK 16 VRS = 0; 2.5 V < VREF ≤ VA+ f= Figure 10. Input Reference Model when VRS = 0 2.3.8. Filter Rate Select The Filter Rate Select bit (FRS) modifies the output word rates of the converter to allow either 50 Hz or 60 Hz rejection when operating from a 4.9152 MHz crystal. If FRS is cleared to logic 0, the word rates and corresponding filter characteristics can be selected (using the Channel Setup Registers) from 7.5, 15, 30, 60, 120, 240, 480, 960, 1920, or 3840 Sps when using a 4.9152 MHz clock. If FRS is set to logic 1, the word rates and corresponding filter characteristics scale by a factor of 5/6, making the selectable word rates 6.25, 12.5, 25, 50, 100, 200, 400, 800, 1600, and 3200 Sps when using a 4.9152 MHz clock. When using other clock frequencies, these selectable word rates will scale linearly with the clock frequency that is used. 25 CS5532/34-BS 2.3.9. Configuration Register Descriptions D31(MSB) D30 PSS PDW D15 D14 NU NU D29 RS D13 NU D28 RV D12 NU D27 IS D11 NU D26 GB D10 NU D25 VRS D9 NU D24 A1 D8 NU D23 A0 D7 NU D22 OLS D6 NU D21 NU D5 NU D20 OGS D4 NU D19 FRS D3 NU D18 NU D2 NU D17 NU D1 NU D16 NU D0 NU PSS (Power Save Select)[31] 0 Standby Mode (Oscillator active, allows quick power-up). 1 Sleep Mode (Oscillator inactive). PDW (Power Down Mode)[30] 0 Normal Mode 1 Activate the power save select mode. RS (Reset System)[29] 0 Normal Operation. 1 Activate a Reset cycle. See System Reset Sequence in the datasheet text. RV (Reset Valid)[28] 0 Normal Operation 1 System was reset. This bit is read only. Bit is cleared to logic zero after the configuration register is read. IS (Input Short)[27] 0 Normal Input 1 All signal input pairs for each channel are disconnected from the pins and shorted internally. GB (Guard Signal Bit)[26] 0 Normal Operation of A0 as an output latch. 1 A0’s output is modified to output the common mode output voltage of the instrumentation amplifier (typically 2.5 V). The output latch select bit is ignored when the guard buffer is activated. VRS (Voltage Reference Select)[25] 0 2.5 V < VREF ≤ [(VA+) - (VA-)] 1 1 V ≤ VREF ≤ 2.5V A1-A0 (Output Latch bits)[24:23] The latch bits (A0 and A1) will be set to the logic state of these bits upon command word execution if the output latch select bit (OLS) is set. Note that these logic outputs are powered from VA+ and VA-. 00 A0 = 0, A1 = 0 01 A0 = 0, A1 = 1 10 A0 = 1, A1 = 0 11 A0 = 1, A1 = 1 Output Latch Select, OLS[22] 0 When low, uses the Channel-Setup Register as the source of A1 and A0. 1 When set, uses the Configuration Register as the source of A1 and A0. NU (Not Used)[21] 0 Must always be logic 0. Reserved for future upgrades. Offset and Gain Select OGS[20] 26 0 Calibration registers used are based on the CS1-CS0 bits of the referenced Setup. 1 Calibration registers used are based on the OG1-OG0 bits of the referenced Setup. DS755F3 CS5532/34-BS Filter Rate Select, FRS[19] 0 Use the default output word rates. 1 Scale all output word rates and their corresponding filter characteristics by a factor of 5/6. NU (Not Used)[18:0] 0 Must always be logic 0. Reserved for future upgrades. 2.4. Setting up the CSRs for a Measurement The CS5532/34 have four Channel-Setup Registers (CSRs). Each CSR contains two 16-bit Setups which are programmed by the user to contain data conversion information such as: 1) which physical channel will be converted, 2) at what gain will the channel be converted, 3) at what word rate will the channel be converted, 4) will the output conversion be unipolar or bipolar, 5) what will be the state of the output latch during the conversion, 6) will the converter delay the start of a conversion to allow time for the output latch to settle before the conversion is begun, and 7) will the open circuit detect current source be activated for that Setup. In addition, when the OGS bit in the Configuration Register is set, the Setup selects which set of offset and gain registers to use when performing conversions or calibrations. Note that a particular physical input channel can be represent- DS755F3 ed in more than one Setup with different output rates, gain ranges, etc. (i.e. each Setup is independently defined). Refer to section 2.4.1 for more details about the Channel Setup Registers. Each 32-bit CSR is individually accessible and contains two 16-bit Setups. As an example, to configure Setup 1 in the CS5532/34 with the write individual channel-setup register command (0x05 hexadecimal), bits 31 to 16 of CSR 1 contains the information for Setup 1 and bits 15 to 0 contain the information for Setup 2. Note that while reading/writing CSRs, two Setups are accessed in pairs as a single 32-bit CSR register. Even if one of the Setups isn’t used, it must be written to or read. Examples detailing the power of the CSRs are provided in section 2.6.3. 27 CS5532/34-BS 2.4.1. Channel-Setup Register Descriptions CSR #1 Setup 1 Bits <127:112> Setup 2 Bits <111:96> #4 Setup 7 Bits <31:16> Setup 8 Bits <15:0> D31(MSB) CS1 D15 CS1 D30 CS0 D14 CS0 D29 G2 D13 G2 D28 G1 D12 G1 D27 G0 D11 G0 D26 WR3 D10 WR3 D25 WR2 D9 WR2 D24 WR1 D8 WR1 D23 WR0 D7 WR0 D22 U/B D6 U/B D21 OL1 D5 OL1 D20 OL0 D4 OL0 D19 DT D3 DT D18 OCD D2 OCD D17 OG1 D1 OG1 D16 OG0 D0 OG0 CS1-CS0 (Channel Select Bits) [31:30] [15:14] 00 Select physical channel 1 01 Select physical channel 2 10 Select physical channel 3 (CS5534 only) 11 Select physical channel 4 (CS5534 only) G2-G0 (Gain Bits) [29:27] [13:11] For VRS = 0, A = 2; For VRS = 1, A = 1; Bipolar input span is twice the unipolar input span. 000 Gain = 1, (Input Span = [(VREF+)-(VREF-)]/1*A for unipolar). 001 Gain = 2, (Input Span = [(VREF+)-(VREF-)]/2*A for unipolar). 010 Gain = 4, (Input Span = [(VREF+)-(VREF-)]/4*A for unipolar). 011 Gain = 8, (Input Span = [(VREF+)-(VREF-)]/8*A for unipolar). 100 Gain = 16, (Input Span = [(VREF+)-(VREF-)]/16*A for unipolar). 101 Gain = 32, (Input Span = [(VREF+)-(VREF-)]/32*A for unipolar). 110 Gain = 64, (Input Span = [(VREF+)-(VREF-)]/64*A for unipolar). WR3-WR0 (Word Rate) [26:23] [10:7] The listed Word Rates are for continuous conversion mode using a 4.9152 MHz clock. All word rates will scale linearly with the clock frequency used. The very first conversion using continuous conversion mode will last longer, as will conversions done with the single conversion mode. See the section on Performing Conversions and Tables 1 and 2 for more details. Bit WR (FRS = 0) WR (FRS = 1) 0000 120 Sps 100 Sps 0001 60 Sps 50 Sps 0010 30 Sps 25 Sps 0011 15 Sps 12.5 Sps 0100 7.5 Sps 6.25 Sps 1000 3840 Sps 3200 Sps 1001 1920 Sps 1600 Sps 1010 960 Sps 800 Sps 1011 480 Sps 400 Sps 1100 240 Sps 200 Sps All other combinations are not used. 28 DS755F3 CS5532/34-BS U/B (Unipolar / Bipolar) [22] [6] 0 Select Bipolar mode. 1 Select Unipolar mode. OL1-OL0 (Output Latch Bits) [21:20] [5:4] The latch bits will be set to the logic state of these bits upon command word execution when the output latch select bit (OLS) in the configuration register is logic 0. Note that the logic outputs on the chip are powered from VA+ and VA-. 00 A0 = 0, A1 = 0 01 A0 = 0, A1 = 1 10 A0 = 1, A1 = 0 11 A0 = 1, A1 = 1 DT (Delay Time Bit) [19] [3] When set, the converter will wait for a delay time before starting a conversion. This allows settling time for A0 and A1 outputs before a conversion begins. The delay time will be 1280 MCLK cycles when FRS = 0, and 1536 MCLK cycles when FRS = 1. 0 Begin Conversions Immediately. 1 Wait 1280 MCLK cycles (FRS = 0) or 1536 MCLK cycles (FRS = 1) before starting conversion. OCD (Open Circuit Detect Bit) [18] [2] When set, this bit activates a 300 nA current source on the input channel (AIN+) selected by the channel select bits. Note that the 300 nA current source is rated at 25°C. At -55°C, the current source doubles to approximately 600 nA. This feature is particularly useful in thermocouple applications when the user wants to drive a suspected open thermocouple lead to a supply rail. 0 Normal mode. 1 Activate current source. OG1-OG0 (Offset / Gain Register Pointer Bits) [17:16] [1:0] These bits are only used when OGS in the Configuration Register is set to ‘1’. They allow the user to select the offset and gain register to use while performing a conversion or calibration. When the OGS bit in the Configuration Register is set to ‘0’, the offset and gain register for the referenced physical channel (CS1CS0 bits of the Setup) will be used. DS755F3 00 Use offset and gain register from physical channel 1 01 Use offset and gain register from physical channel 2 10 Use offset and gain register from physical channel 3 11 Use offset and gain register from physical channel 4 29 CS5532/34-BS 2.5. Calibration Calibration is used to set the zero and gain slope of the ADC’s transfer function. The CS5532/34 offer both self calibration and system calibration. Note: After the ADCs are reset, they are functional and can perform measurements without being calibrated (remember that the VRS bit in the configuration register must be properly configured). In this case, the converter will utilize the initialized values of the on-chip registers (Gain = 1.0, Offset = 0.0) to calculate output words. Any initial offset and gain errors in the internal circuitry of the chip will remain. tion of the input span (bipolar span is 2 times the unipolar span, gain register = 1.000...000 decimal). The MSB in the offset register determines if the offset to be trimmed is positive or negative (0 positive, 1 negative). Note that the magnitude of the offset that is trimmed from the input is mapped through the gain register. The converter can typically trim ±100 percent of the input span. As shown in the Gain Register section, the gain register spans from 0 to (64 - 2-24). The decimal equivalent meaning of the gain register is 29 D = b 2.5.1. Calibration Registers 5 D29 2 +b 4 D28 2 +b 3 D27 2 +…+b D0 2 – 24 ∑ bDi 2 ) = ( – 24 + i ) i=0 The CS5532/34 converters have an individual offset and gain register for each channel input. The gain and offset registers, which are used during both self and system calibration, are used to set the zero and gain slope of the converter’s transfer function. As shown in Offset Register section, one LSB in the offset register is 1.835007966 X 2-24 propor- where the binary numbers have a value of either zero or one (bD29 is the binary value of bit D29). While gain register settings of up to 64 - 2-24 are available, the gain register should never be set to values above 40. 2.5.2. Gain Register MSB NU D30 NU D29 D28 D27 D26 D25 D24 D23 D22 D21 D20 D19 D18 D17 D16 25 24 23 22 21 20 2-1 2-2 2-3 2-4 2-5 2-6 2-7 0 0 0 0 0 0 0 1 0 0 0 0 0 0 0 2-8 0 D15 D14 D13 D12 D11 D10 D9 D8 D7 D6 D5 D4 D3 D2 D1 LSB 2-9 0 2-10 0 2-11 0 2-12 0 2-13 0 2-14 0 2-15 0 2-16 0 2-17 0 2-18 0 2-19 0 2-20 0 2-21 0 222 0 2-23 0 2-24 0 The gain register span is from 0 to (64-2-24). After Reset D24 is 1, all other bits are ‘0’. 2.5.3. Offset Register MSB Sign D30 D29 D28 D27 D26 D25 D24 D23 D22 D21 D20 D19 D18 D17 D16 2-4 2-5 2-6 2-7 2-8 2-9 2-10 2-11 2-12 2-13 2-14 2-15 0 2 0 2-3 0 0 0 0 0 0 0 0 0 0 0 0 0 2-16 0 D15 D14 D13 D12 D11 D10 D9 D8 2-17 0 2-18 0 2-19 0 2-20 0 2-21 0 2-22 0 2-23 0 2-24 0 D7 NU D6 NU D5 NU D4 NU D3 NU D2 NU D1 NU LSB NU 0 0 0 0 0 0 0 0 -2 One LSB represents 1.835007966 X 2-24 proportion of the input span (bipolar span is 2 times unipolar span). Offset and data word bits align by MSB. After reset, all bits are ‘0’. The offset register is stored as a 32-bit, two’s complement number, where the last 8 bits are all 0. 30 DS755F3 CS5532/34-BS 2.5.4. Performing Calibrations To perform a calibration, the user must send a command byte with its MSB=1, its pointer bits (CSRP2-CSRP0) set to address the desired Setup to calibrate, and the appropriate calibration bits (CC2CC0) set to choose the type of calibration to be performed. Note that calibration assumes that the CSRs have been previously initialized because the information concerning the physical channel, its filter rate, gain range, and polarity, comes from the channel-setup register addressed by the pointer bits in the command byte. Once the CSRs are initialized, a calibration can be performed with one command byte. The length of time it takes to do a calibration is slightly less than the amount of time it takes to do a single conversion (see Table 1 for single conversion timing). Offset calibration takes 608 clock cycles less than a single conversion when FRS = 0, and 729 clock cycles less when FRS = 1. Gain calibration takes 128 clock cycles less than a single conversion when FRS = 0, and 153 clock cycles less when FRS = 1. Once a calibration cycle is complete, SDO falls and the results are automatically stored in either the gain or offset register for the physical channel being calibrated when the OGS bit in the Configuration Register is set to ‘0’. If the OGS bit is set to ‘1’, the results will be stored in the register specified by the OG1-OG0 bits of the selected Setup. See the OGS bit description for more details (Section 2.3.7). SDO will remain low until the next command word is begun. If additional calibrations are performed while referencing the same calibration DS755F3 registers, the last calibration results will replace the effects from the previous calibration as only one offset and gain register is available per physical channel. Only one calibration is performed with each command byte. To calibrate all the channels, additional calibration commands are necessary. 2.5.5. Self Calibration The CS5532/34 offer both self-offset and self-gain calibrations. For the self calibration of offset, the converters internally tie the inputs of the 1x amplifier together and routes them to the AIN- pin as shown in Figure 11. For accurate self calibration of offset to occur, the AIN pins must be at the proper common-mode voltage as specified in the Analog Characteristics section. Self-offset calibration uses the 1x gain amplifier, and is therefore not valid in the 2x-64x gain ranges. A self-offset calibration of these gain ranges can be performed by setting the IS bit in the configuration register to a ‘1’, and performing a system offset calibration. The IS bit must be returned to ‘0’ afterwards for normal operation of the device. For self calibration of gain, the differential inputs of the modulator are connected to VREF+ and VREF- as shown in Figure 12. Self calibration of gain will not work with (VREF+ - VREF-) > 2.5V. Self calibration of gain is performed in the GAIN = 1x mode without regard to the setup register’s gain setting. Gain errors in the PGIA gain steps 2x to 64x are not calibrated as this would require an accurate low-voltage source other than the reference voltage. A system calibration of gain should be performed if accurate gains are to be achieved on the ranges other than 1x, or when (VREF+ – VREF-) > 2.5V. 31 CS5532/34-BS 2.5.6. System Calibration For the system calibration functions, the user must supply the converter’s calibration signals which represent ground and full scale. When a system offset calibration is performed, a ground-referenced signal must be applied to the converters. Figure 13 illustrates system offset calibration. As shown in Figure 14, the user must input a signal representing the positive full-scale point to perform a system gain calibration. In either case, the calibration signals must be within the specified calibration limits for each specific calibration step (refer to the System Calibration Specifications). 2.5.7. Calibration Tips Calibration steps are performed at the output word rate selected by the WR2-WR0 bits of the channel setup registers. Due to limited register lengths in the faster word-rate filters (240 Sps and higher), channels that are used at these rates should also be calibrated in one of these word rates, and channels used in the lower word rates (120 Sps and lower) should be calibrated at one of these lower rates. Since higher word rates result in conversion words with more peak-to-peak noise, calibration should be performed at the lowest possible output word rate for maximum accuracy. For the 7.5 Sps to 120 Sps word rate settings, calibrations can be performed at 7.5 Sps, and for 240 Sps and higher, calibration can be performed at 240 Sps. To minimize digital noise near the device, the user should wait for each calibration step to be completed before reading or writing to the serial port. Reading the calibration registers and averaging multiple calibrations together can produce a more accurate calibration result. Note that accessing the ADC’s serial port before a calibration has finished may result in the loss of synchronization between the mi- OPEN AIN+ AIN+ + + + XGAIN 1X GAIN AIN- _ _ AIN- + - - OPEN VREF+ Reference + - VREF- CLOSED CLOSED Figure 12. Self Calibration of Gain Figure 11. Self Calibration of Offset External Connections External Connections + + + AIN+ 0V +AIN- Figure 13. System Calibration of Offset 32 Full Scale +- XGAIN - CM +- + AIN+ XGAIN - - CM +- AIN- Figure 14. System Calibration of Gain DS755F3 CS5532/34-BS crocontroller and the ADC, and may prematurely halt the calibration cycle. For maximum accuracy, calibrations should be performed for both offset and gain (selected by changing the G2-G0 bits of the channel-setup registers). Note that only one gain range can be calibrated per physical channel when the OGS bit in the Configuration Register is set to ‘0’. Multiple gain ranges can be calibrated for a single channel by manipulating the OGS bit and the OG1-OG0 bits of the selected Setup (see Section 2.3.7 for more details). If factory calibration of the user’s system is performed using the system calibration capabilities of the CS5532/34, the offset and gain register contents can be read by the system microcontroller and recorded in non-volatile memory. These same calibration words can then be uploaded into the offset and gain registers of the converter when power is first applied to the system, or when the gain range is changed. When the device is used without calibration, the uncalibrated gain accuracy is about ±1% and the gain tracking from range to range (2x to 64x) is approximately ±0.3 percent. Note that the gain from the offset register to the output is 1.83007966 decimal, not 1. If a user wants to adjust the calibration coefficients externally, they will need to divide the information to be written to the offset register by the scale factor of 1.83007966. (This discussion assumes that the gain register is 1.000...000 decimal. The offset register is also multiplied by the gain register before being applied to the output conversion words). 2.5.8. Limitations in Calibration Range System calibration can be limited by signal headroom in the analog signal path inside the chip as discussed under the Analog Input section of this data sheet. For gain calibration, the full-scale input signal can be reduced to 3% of the nominal fullscale value. At this point, the gain register is approximately equal to 33.33 (decimal). While the DS755F3 gain register can hold numbers all the way up to 64 - 2-24, gain register settings above a decimal value of 40 should not be used. With the converter’s intrinsic gain error, this minimum full-scale input signal may be higher or lower. In defining the minimum Full Scale Calibration Range (FSCR) under Analog Characteristics, margin is retained to accommodate the intrinsic gain error. Inversely, the input full-scale signal can be increased to a point in which the modulator reaches its 1’s density limit of 86 percent, which under nominal conditions occurs when the full-scale input signal is 1.1 times the nominal full-scale value. With the chip’s intrinsic gain error, this maximum full-scale input signal maybe higher or lower. In defining the maximum FSCR, margin is again incorporated to accommodate the intrinsic gain error. 2.6. Performing Conversions The CS5532/34 offers two distinctly different conversion modes. The three sections that follow detail the differences and provide examples illustrating how to use the conversion modes with the channelsetup registers. 2.6.1. Single Conversion Mode Based on the information provided in the channelsetup registers (CSRs), after the user transmits the conversion command, a single, fully settled conversion is performed. The command byte includes a pointer address to the Setup register to be used during the conversion. Once transmitted, the serial port enters data mode where it waits until the conversion is complete. When the conversion data is available, SDO falls to logic 0. Forty SCLKs are then needed to read the conversion data word. The first 8 SCLKs are used to clear the SDO flag. During the first 8 SCLKs, SDI must be logic 0. The last 32 SCLKs are needed to read the conversion result. Note that the user is forced to read the conversion in single conversion mode as SDO will remain low (i.e. the serial port is in data mode) until SCLK transitions 40 times. After reading the data, the se- 33 CS5532/34-BS rial port returns to the command mode, where it waits for a new command to be issued. The single conversion mode will take longer than conversions performed in the continuous conversion mode. The number of clock cycles a single conversion takes for each Output Word Rate (OWR) setting is listed in Table 1. The ±8 (FRS = 0) or ±10 (FRS = 1) clock ambiguity is due to internal synchronization between the SCLK input and the oscillator. Note: In the single conversion mode, more than one conversion is actually performed, but only the final, fully settled result is output to the conversion data register. Table 1. Conversion Timing – Single Mode (WR3-WR0) Clock Cycles FRS = 0 FRS = 1 0000 171448 ± 8 205738 ± 10 0001 335288 ± 8 402346 ± 10 0010 662968 ± 8 795562 ± 10 0011 1318328 ± 8 1581994 ± 10 0100 2629048 ± 8 3154858 ± 10 1000 7592 ± 8 9110 ± 10 1001 17848 ± 8 21418 ± 10 1010 28088 ± 8 33706 ± 10 1011 48568 ± 8 58282 ± 10 1100 89528 ± 8 107434 ± 10 2.6.2. Continuous Conversion Mode Based on the information provided in the channelsetup registers (CSRs), continuous conversions are performed using the Setup register contents pointed to by the conversion command. The command byte includes a pointer address to the Setup register to be used during the conversion. Once transmitted, the serial port enters data mode where it waits until a conversion is complete. After the conversion is 34 done, SDO falls to logic 0. Forty SCLKs are then needed to read the conversion. The first 8 SCLKs are used to clear the SDO flag. The last 32 SCLKs are needed to read the conversion result. If ‘00000000’ is provided to SDI during the first 8 SCLKs when the SDO flag is cleared, the converter remains in this conversion mode and continues to convert the selected channel using the same CSR Setup. In continuous conversion mode, not every conversion word needs to be read. The user needs only to read the conversion words required for the application as SDO rises and falls to indicate the availability of new conversion data. Note that if a conversion is not read before the next conversion data becomes available, it will be lost and replaced by the new conversion data. To exit this conversion mode, the user must provide ‘11111111’ to the SDI pin during the first 8 SCLKs after SDO falls. If the user decides to exit, 32 SCLKs are required to clock out the last conversion before the converter returns to command mode. The number of clock cycles a continuous conversion takes for each Output Word Setting is listed in Table 2. The first conversion from the part in continuous conversion mode will be longer than the following conversions due to start-up overhead. The ± 8 (FRS = 0) or ± 10 (FRS = 1) clock ambiguity is due to internal synchronization between the SCLK input and the oscillator. Note: When changing channels, or after performing calibrations and/or single conversions, the user must ignore the first three (for OWRs less than 3200 Sps, MCLK = 4.9152 MHz) or first five (for OWR ≥ 3200 Sps) conversions in continuous conversion mode, as residual filter coefficients must be flushed from the filter before accurate conversions are performed. DS755F3 CS5532/34-BS Table 2. Conversion Timing – Continuous Mode FRS (WR3-WR0) 0 0 0 0 0 0 0 0 0 0 1 1 1 1 1 1 1 1 1 1 0000 0001 0010 0011 0100 1000 1001 1010 1011 1100 0000 0001 0010 0011 0100 1000 1001 1010 1011 1100 Clock Cycles Clock Cycles (First Conversion) (All Other Conversions) 89528 ± 8 40960 171448 ± 8 81920 335288 ± 8 163840 662968 ± 8 327680 1318328 ± 8 655360 2472 ± 8 1280 12728 ± 8 2560 17848 ± 8 5120 28088 ± 8 10240 48568 ± 8 20480 107434 ± 10 49152 205738 ± 10 98304 402346 ± 10 196608 795562 ± 10 393216 1581994 ± 10 786432 2966 ± 10 1536 15274 ± 10 3072 21418 ± 10 6144 33706 ± 10 12288 58282 ± 10 24576 2.6.3. Examples of Using CSRs to Perform Conversions and Calibrations Any time a calibration or conversion command is issued (C, MC, and CC2-CC0 bits must be properly set), the CSRP2-CSRP0 bits in the command byte are used as pointers to address one of the Setups in the channel-setup registers (CSRs). Table 3 details the address decoding of the pointer the bits. Table 3. Command Byte Pointer (CSRP2-CSRP0) CSR Location 000 CSR #1 001 010 011 100 101 110 111 DS755F3 CSR #1 CSR #2 CSR #2 CSR #3 CSR #3 CSR#4 CSR #4 Setup 1 2 3 4 5 6 7 8 The examples that follow detail situations that a user might encounter when acquiring a conversion or calibrating the converter. These examples assume that the CSRs are programmed with the following physical channel order: 4, 1, 1, 2, 4, 3, 4, 4. A physical channel is defined as the actual input channel (AIN1 to AIN4) to which an external signal is connected. Example 1: Single conversion using Setup 1. The command issued is ‘10000000’. This instructs the converter to perform a single conversion referencing Setup 1 (CSRP2 - CSRP0 = ‘000’) In this example, Setup 1 points to physical channel 4. After the command is received and decoded, the ADC performs a conversion on physical channel 4 and SDO falls to indicate that the conversion is complete. To read the conversion, 40 SCLKs are then required. Once the conversion data has been read, the serial port returns to the command mode. Example 2: Continuous conversions using Setup 3. The command issued is ‘11010000’. This instructs the converter to perform continuous conversions referencing Setup 3 (CSRP2 - CSRP0 = ‘010’). In this example, Setup 3 points to physical channel 1. After the command is received and decoded, the ADC performs a conversion on physical channel 1 and SDO falls to indicate that the conversion is complete. The user now has three options. The user can acquire the conversion and remain in this mode, acquire the conversion and exit this mode, or ignore the conversion and wait for a new conversion at the next update interval, as detailed in the continuous conversion section. Example 3: Calibration using Setup 4. This example assumes that the OGS bit in the Configuration Register is set to ‘0’. The command issued is ‘10011001’. This instructs the converter to perform a self offset calibration referencing Setup 4 (CSRP2 - CSRP0 = ‘011’). In this example, Setup 4 points to physical channel 2. After the command is received and decoded, the ADC performs a self 35 CS5532/34-BS offset calibration on physical channel 2 and SDO falls to indicate that the calibration is complete. To perform additional calibrations, more commands must be issued. An example of a synchronous system using two CS5532 parts is shown in Figure 15. CS5532 SDO SDI Note: The CSRs need not be written. If they are not initialized, all the Setups point to their default settings irrespective of the conversion or calibration mode (i.e conversions can be performed, but only physical channel 1 will be converted). Further note that filter convolutions are reset (i.e. flushed) if consecutive conversions are performed on two different physical channels. If consecutive conversions are performed on the same physical channel, the filter is not reset. This allows the ADCs to more quickly settle full scale step inputs. 2.7. Using Multiple ADCs Synchronously Some applications require synchronous data outputs from multiple ADCs converting different analog channels. Multiple CS5532/34 parts can be synchronized in a single system by using the following guidelines: 1) All of the ADCs in the system must be operated from the same oscillator source. 2) All of the ADCs in the system must share common SCLK and SDI lines. 3) A software reset must be performed at the same time for all of the ADCs after system power-up (by selecting all of the ADCs using their respective CS pins, and writing the reset sequence to all parts, using SDI and SCLK). 4) A start conversion command must be sent to all of the ADCs in the system at the same time. The ±8 clock cycles of ambiguity for the first conversion (or for a single conversion) will be the same for all ADCs, provided that they were all reset at the same time. 5) Conversions can be obtained by monitoring SDO on only one ADC, (bring CS high for all but one part) and reading the data out of each part individually, before the next conversion data words are ready. 36 SCLK CS OSC2 µC CS5532 SDO SDI SCLK CS OSC2 CLOCK SOURCE Figure 15. Synchronizing Multiple ADCs 2.8. Conversion Output Coding The CS5532/34 output 24-bit data conversion words. To read a conversion word the user must read the conversion data register. The conversion data register is 32 bits long and outputs the conversions MSB first. The last byte of the conversion data register contains data monitoring flags. The channel indicator (CI) bits keep track of which physical channel was converted and the overrange flag (OF) monitors to determine if a valid conversion was performed. Refer to the Conversion Data Output Descriptions section for more details. The CS5532/34 output data conversions in binary format when operating in unipolar mode and in two's complement format when operating in bipolar mode. Table 4 shows the code mapping for both unipolar and bipolar mode. VFS in the tables refers to the positive full-scale voltage range of the converter in the specified gain range, and -VFS refers to the negative full-scale voltage range of the converter. The total differential input range (between AIN+ and AIN-) is from 0 to VFS in unipolar mode, and from -VFS to VFS in bipolar mode. DS755F3 CS5532/34-BS Table 4. Output Coding for 24-bit CS5532 and CS5534 Unipolar Input Voltage Offset Binary Bipolar Input Voltage >(VFS-1.5 LSB) FFFFFF >(VFS-1.5 LSB) 7FFFFF VFS-1.5 LSB FFFFFF -----FFFFFE VFS-1.5 LSB 7FFFFF -----7FFFFE 800000 -----7FFFFF -0.5 LSB 000000 -----FFFFFF 000001 -----000000 -VFS+0.5 LSB 800001 -----800000 000000 <(-VFS+0.5 LSB) 800000 VFS/2-0.5 LSB +0.5 LSB <(+0.5 LSB) Two's Complement 2.8.1. Conversion Data Output Descriptions D31(MSB) D30 MSB 22 D15 D14 7 6 D29 21 D13 5 D28 20 D12 4 D27 19 D11 3 D26 18 D10 2 D25 17 D9 1 D24 16 D8 LSB D23 15 D7 0 D22 14 D6 0 D21 13 D5 0 D20 12 D4 0 D19 11 D3 0 D18 10 D2 OF D17 9 D1 CI1 D16 8 D0 CI0 Conversion Data Bits [31:8] These bits depict the latest output conversion. NU (Not Used) [7:3] These bits are masked logic zero. OF (Over-range Flag Bit) [2] 0 Bit is clear when over-range condition has not occurred. 1 Bit is set when input signal is more positive than the positive full scale, more negative than zero (unipolar mode) or when the input is more negative than the negative full scale (bipolar mode). CI (Channel Indicator Bits) [1:0] These bits indicate which physical input channel was converted. DS755F3 00 Physical Channel 1 01 Physical Channel 2 10 Physical Channel 3 11 Physical Channel 4 37 CS5532/34-BS 2.9. Digital Filter The CS5532/34 have linear phase digital filters which are programmed to achieve a range of output word rates (OWRs) as stated in the Channel-Setup Register Descriptions section. The ADCs use a Sinc5 digital filter to output word rates at 3200 Sps and 3840 Sps (MCLK = 4.9152 MHz). Other output word rates are achieved by using the Sinc5 filter followed by a Sinc3 filter with a programmable decimation rate. Figure 16 shows the magnitude response of the 60 Sps filter, while Figures 17 and 18 show the magnitude and phase response of the filter at 120 Sps. The Sinc3 is active for all output word rates except for the 3200 Sps and 3840 Sps Sin x 3 x (MCLK = 4.9152 MHz) rate. The Z-transforms of the two filters are shown in Figure 19. For the Sinc3 filter, “D” is the programmable decimation ratio, which is equal to 3840/OWR when FRS = 0 and 3200/OWR when FRS = 1. The converter’s digital filters scale with MCLK. For example, with an output word rate of 120 Sps, the filter’s corner frequency is at 31 Hz. If MCLK is increased to 5.0 MHz, the OWR increases by 1.0175% and the filter’s corner frequency moves to 31.54 Hz. Note that the converter is not specified to run at MCLK clock frequencies greater than 5 MHz. ( ) 0 -40 Gain (dB) Gain (dB) 0 -80 Flatness Frequency dB 2 -0.01 4 -0.05 6 -0.11 8 -0.19 10 -0.30 12 -0.43 14 -0.59 16 -0.77 19 -1.09 32 -3.13 -40 -80 -120 -120 0 60 120 180 240 0 300 40 80 120 Frequency (Hz) Frequency (Hz) Figure 16. Digital Filter Response (WR = 60 Sps) Figure 17. 120 Sps Filter Magnitude Plot to 120 Hz Phase (Degrees) 180 90 0 ( 1 – z –80 ) 5 ( 1 – z – 16 ) 3- ----------------------( 1 – z –4 ) 2 ----------------------( 1 – z –2 ) 3 × × Sinc 5 = -------------------------5- × ------------------------3 2 – 16 – 4 – 2 (1 – z ) (1 – z ) (1 – z ) ( 1 – z –1 ) 3 -90 ( 1 – z –D ) 3 Sinc 3 = ------------------------3( 1 – z –1 ) -180 0 30 60 90 120 Frequency (Hz) Figure 18. 120 Sps Filter Phase Plot to 120 Hz 38 Note: See the text regarding the Sinc3 filter’s decimation ratio “D”. Figure 19. Z-Transforms of Digital Filters DS755F3 CS5532/34-BS 2.10. Clock Generator The CS5532/34 include an on-chip inverting amplifier which can be connected with an external crystal to provide the master clock for the chip. Figure 20 illustrates the on-chip oscillator. It includes loading capacitors and a feedback resistor to form a Pierce oscillator configuration. The chips are designed to operate using a 4.9152 MHz crystal; however, other crystals with frequencies between 1 MHz to 5 MHz can be used. One lead of the crystal should be connected to OSC1 and the other to OSC2. Lead lengths should be minimized to reduce stray capacitance. Note that while using the on-chip oscillator, neither OSC1 or OSC2 is capable of directly driving any off-chip logic. When the on-chip oscillator is used, the voltage on OSC2 is typically 0.5 V peak-to-peak. This signal is not compatible with external logic unless additional external circuitry is added. The OSC2 output should be used if the on-chip oscillator output is used to drive other circuitry. The designer can use an external CMOS compatible oscillator to drive OSC2 with a 1 MHz to 5 MHz clock for the ADC. The external clock into OSC2 must overdrive the 60 µA output of the onchip amplifier. This will not harm the on-chip circuitry. In this scheme, OSC1 should be left unconnected. 2.11. Power Supply Arrangements The CS5532/34 are designed to operate from single or dual analog supplies and a single digital supply. The following power supply connections are possible: VA+ = +5 V; VA- = 0 V; VD+ = +3 V to +5 V VA+ = +2.5 V; VA- = -2.5 V; VD+ = +3 V to +5 V VA+ = +3 V; VA- = -3 V; VD+ = +3 V A VA+ supply of +2.5 V, +3.0 V, or +5.0 V should be maintained at ±5% tolerance. A VA- supply of -2.5 V or -3.0 V should be maintained at ±5% tolerance. VD+ can extend from +2.7 V to +5.5 V with the additional restriction that [(VD+) – (VA-)] < 7.5 V. Figure 21 illustrates the CS5532 connected with a single +5.0 V supply to measure differential inputs relative to a common mode of 2.5 V. Figure 22 illustrates the CS5532 connected with ±2.5 V bipolar analog supplies and a +3 V to +5 V digital supply to measure ground referenced bipolar signals. Figures 23 and 24 illustrate the CS5532 connected with ±3 V analog supplies and a +3 V digital supply to measure ground referenced bipolar signals. Figure 25 illustrates alternate bridge configurations which can be measured with the converter. Voltage V1 can be measured with the PGIA gain set to 1x as the input amplifier on this gain setting can go rail-to-rail. Voltage V2 should be measured with the PGIA gain set at 2x or higher as the instrumen- 1 MΩ ~~ 60 µA VTH + 20 pF OSC1 20 pF OSC2 MCLK NOTE: 20 pF capacitors are on chip and should not be added externally. Figure 20. On-chip Oscillator Model DS755F3 39 CS5532/34-BS tation amplifier used on these gain ranges achieves lower noise. 10 Ω +5 V Analog Supply 0.1 µF 0.1 µF 5 VA+ 18 VREF+ 15 VD+ OSC2 9 17 VREF3 C1 - + OSC1 10 Optional Clock Source 4.9152 MHz 22 nF CS5532 4 1 2 20 19 7 8 C2 AIN1+ AIN1AIN2+ AIN2A0 A1 VA 6 CS SDI SDO SCLK 14 13 12 11 Serial Data Interface DGND 16 Figure 21. CS5532 Configured with a Single +5 V Supply 40 DS755F3 CS5532/34-BS +2.5 V Analog Supply +3 V ~ +5 V Digital 0.1 µF Supply 0.1 µF 5 VA+ - + 15 VD+ 18 VREF+ OSC2 17 VREF3 C1 OSC1 9 10 Optional Clock Source 4.9152 MHz 22 nF CS5532 4 1 2 20 19 7 8 -2.5 V Analog Supply C2 AIN1+ AIN1AIN2+ AIN2A0 A1 VA 6 CS SDI SDO SCLK 14 13 12 11 Serial Data Interface DGND 16 Figure 22. CS5532 Configured with ±2.5 V Analog Supplies 10 Ω +3 V Analog Supply 0.1 µF 0.1 µF 5 VA+ - + 18 VREF+ OSC2 17 VREF3 C1 OSC1 9 10 Optional Clock Source 4.9152 MHz 22 nF CS5532 4 1 2 20 19 7 8 -3 V Analog Supply 15 VD+ C2 AIN1+ AIN1AIN2+ AIN2A0 A1 VA 6 CS SDI SDO SCLK 14 13 12 11 Serial Data Interface DGND 16 Figure 23. CS5532 Configured with ±3 V Analog Supplies DS755F3 41 CS5532/34-BS 10 Ω +3 V Analog Supply 0.1 µF 0.1 µF 5 VA+ 1 AIN1+ 15 VD+ OSC2 2 AIN13 C1 OSC1 CS5532 4 C2 18 VREF+ 22 nF 2.5V 17 20 19 7 8 Cold Junction -3 V Analog Supply VREFAIN2+ AIN2A0 A1 VA 6 CS SDI SDO SCLK 9 10 14 13 12 11 Optional Clock Source 4.9152 MHz Serial Data Interface DGND 16 Figure 24. CS5532 Configured for Thermocouple Measurement V+ V+ V1 V2 V1 V2 (a) (b) Figure 25. Bridge with Series Resistors 42 DS755F3 CS5532/34-BS 2.12. Getting Started This A/D converter has several features. From a software programmer’s prospective, what should be done first? To begin, a 4.9152 MHz or 4.096 MHz crystal takes approximately 20 ms to start. To accommodate for this, it is recommended that a software delay of approximately 20 ms start the processor’s ADC initialization code. Next, since the CS5532/34 do not provide a power-on-reset function, the user must first initialize the ADC to a known state. This is accomplished by resetting the ADC’s serial port with the Serial Port Initialization sequence. This sequence resets the serial port to the command mode and is accomplished by transmitting 15 SYNC1 command bytes (0xFF hexadecimal), followed by one SYNC0 command (0xFE hexadecimal). Once the serial port of the ADC is in the command mode, the user must reset all the internal logic by performing a system reset sequence (see 2.3.2 System Reset Sequence). The next action is to initialize the voltage reference mode. The voltage reference select (VRS) bit in the DS755F3 configuration register must be set based upon the magnitude of the reference voltage between the VREF+ and the VREF- pins. After this, the channel-setup registers (CSRs) should be initialized, as these registers determine how calibrations and conversions will be performed. Once the CSRs are initialized, the user has three options in calibrating the ADC: 1) don’t calibrate and use the default settings; 2) perform self or system calibrations; or 3) upload previously saved calibration results to the offset and gain registers. At this point, the ADC is ready to perform conversions. 2.13. PCB Layout For optimal performance, the CS5532/34 should be placed entirely over an analog ground plane. All grounded pins on the ADC, including the DGND pin, should be connected to the analog ground plane that runs beneath the chip. In a split-plane system, place the analog-digital plane split immediately adjacent to the digital portion of the chip. 43 CS5532/34-BS 3. PIN DESCRIPTIONS DIFFERENTIAL ANALOG INPUT AIN1+ 1 DIFFERENTIAL ANALOG INPUT AIN1- 2 AMPLIFIER CAPACITOR CONNECT C1 AMPLIFIER CAPACITOR CONNECT 20 AIN2+ DIFFERENTIAL ANALOG INPUT 19 AIN2- DIFFERENTIAL ANALOG INPUT 3 18 VREF+ VOLTAGE REFERENCE INPUT C2 4 17 VREF- VOLTAGE REFERENCE INPUT POSITIVE ANALOG POWER VA+ 5 16 DGND DIGITAL GROUND 15 CS5532 NEGATIVE ANALOG POWER VA- 6 VD+ POSITIVE DIGITAL POWER LOGIC OUTPUT (ANALOG)/GUARD A0 7 14 CS CHIP SELECT LOGIC OUTPUT (ANALOG)/GUARD A1 8 13 SDI SERIAL DATA INPUT MASTER CLOCK OSC2 9 12 SDO SERIAL DATA OUT MASTER CLOCK OSC1 10 11 SCLK SERIAL CLOCK INPUT 24 AIN2+ DIFFERENTIAL ANALOG INPUT 23 AIN2- DIFFERENTIAL ANALOG INPUT DIFFERENTIAL ANALOG INPUT AIN1+ 1 DIFFERENTIAL ANALOG INPUT DIFFERENTIAL ANALOG INPUT AIN1- 2 AIN4+ 3 22 AIN3+ DIFFERENTIAL ANALOG INPUT DIFFERENTIAL ANALOG INPUT AIN4- 4 21 AIN3- DIFFERENTIAL ANALOG INPUT AMPLIFIER CAPACITOR CONNECT C1 5 20 VREF+ VOLTAGE REFERENCE INPUT AMPLIFIER CAPACITOR CONNECT C2 6 19 VREF- VOLTAGE REFERENCE INPUT POSITIVE ANALOG POWER VA+ 7 18 DGND DIGITAL GROUND 17 CS5534 NEGATIVE ANALOG POWER VA- 8 VD+ POSITIVE DIGITAL POWER LOGIC OUTPUT (ANALOG)/GUARD A0 9 16 CS CHIP SELECT LOGIC OUTPUT (ANALOG)/GUARD A1 10 15 SDI SERIAL DATA INPUT MASTER CLOCK OSC2 11 14 SDO SERIAL DATA OUT MASTER CLOCK OSC1 12 13 SCLK SERIAL CLOCK INPUT Clock Generator OSC1; OSC2 - Master Clock. An inverting amplifier inside the chip is connected between these pins and can be used with a crystal to provide the master clock for the device. Alternatively, an external (CMOS compatible) clock (powered relative to VD+) can be supplied into the OSC2 pin to provide the master clock for the device. Control Pins and Serial Data I/O CS - Chip Select. When active low, the port will recognize SCLK. When high the SDO pin will output a high impedance state. CS should be changed when SCLK = 0. 44 DS755F3 CS5532/34-BS SDI - Serial Data Input. SDI is the input pin of the serial input port. Data will be input at a rate determined by SCLK. SDO - Serial Data Output. SDO is the serial data output. It will output a high impedance state if CS = 1. SCLK - Serial Clock Input. A clock signal on this pin determines the input/output rate of the data for the SDI/SDO pins respectively. This input is a Schmitt trigger to allow for slow rise time signals. The SCLK pin will recognize clocks only when CS is low. A0 - Logic Output (Analog)/Guard, A1 - Logic Output (Analog). The logic states of A1-A0 mimic the OL1-OL0 bits in the selected Setup, or the A1-A0 bits in the Configuration Register, depending on the state of the OLS bit in the Configuration Register. Logic Output 0 = VA-, and Logic Output 1 = VA+. Alternately, A0 can be used as a guard drive for the instrumentation amplifier with proper setting of the GB bit in the Configuration Register. Measurement and Reference Inputs AIN1+, AIN1-, AIN2+, AIN2- AIN3+, AIN3-, AIN4+, AIN4- - Differential Analog Input. Differential input pins into the device. VREF+, VREF- - Voltage Reference Input. Fully differential inputs which establish the voltage reference for the on-chip modulator. C1, C2 - Amplifier Capacitor Inputs. Connections for the instrumentation amplifier’s capacitor. Power Supply Connections VA+ - Positive Analog Power. Positive analog supply voltage. VD+ - Positive Digital Power. Positive digital supply voltage (nominally +3.0 V or +5 V). VA- - Negative Analog Power. Negative analog supply voltage. DGND - Digital Ground. Digital Ground. DS755F3 45 CS5532/34-BS 4. SPECIFICATION DEFINITIONS Linearity Error The deviation of a code from a straight line which connects the two endpoints of the ADC transfer function. One endpoint is located 1/2 LSB below the first code transition and the other endpoint is located 1/2 LSB beyond the code transition to all ones. Units in percent of fullscale. Differential Nonlinearity The deviation of a code's width from the ideal width. Units in LSBs. Full Scale Error The deviation of the last code transition from the ideal [{(VREF+) - (VREF-)} - 3/2 LSB]. Units are in LSBs. Unipolar Offset The deviation of the first code transition from the ideal (1/2 LSB above the voltage on the AINpin.). When in unipolar mode (U/B bit = 1). Units are in LSBs. Bipolar Offset The deviation of the mid-scale transition (111...111 to 000...000) from the ideal (1/2 LSB below the voltage on the AIN- pin). When in bipolar mode (U/B bit = 0). Units are in LSBs. 46 DS755F3 CS5532/34-BS 5. ORDERING INFORMATION Model Number Bits Channels Linearity Error (Max) Temperature Range Package CS5532-BS 24 2 ±0.0015% -40°C to +85°C 20-pin 0.2" Plastic SSOP CS5532-BSZ 24 2 ±0.0015% -40°C to +85°C 20-pin 0.2" Plastic SSOP, Lead Free CS5534-BS 24 4 ±0.0015% -40°C to +85°C 24-pin 0.2" Plastic SSOP CS5534-BSZ 24 4 ±0.0015% -40°C to +85°C 24-pin 0.2" Plastic SSOP, Lead Free 6. ENVIRONMENTAL, MANUFACTURING, & HANDLING INFORMATION Model Number Peak Reflow Temp MSL Rating* Max Floor Life CS5532-BS 240 °C 2 365 Days CS5532-BSZ 260 °C 3 7 Days CS5534-BS 240 °C 2 365 Days CS5534-BSZ 260 °C 3 7 Days * MSL (Moisture Sensitivity Level) as specified by IPC/JEDEC J-STD-020. DS755F3 47 CS5532/34-BS 7. PACKAGE DRAWINGS 20 PIN SSOP PACKAGE DRAWING N D E11 A2 E e b2 SIDE VIEW A1 A ∝ L END VIEW SEATING PLANE 1 2 3 TOP VIEW INCHES DIM A A1 A2 b D E E1 e L ∝ MIN -0.002 0.064 0.009 0.272 0.291 0.197 0.024 0.025 0° MAX 0.084 0.010 0.074 0.015 0.295 0.323 0.220 0.027 0.040 8° MILLIMETERS MIN MAX -2.13 0.05 0.25 1.62 1.88 0.22 0.38 6.90 7.50 7.40 8.20 5.00 5.60 0.61 0.69 0.63 1.03 0° 8° NOTE 2,3 1 1 Notes: 1. “D” and “E1” are reference datums and do not included mold flash or protrusions, but do include mold mismatch and are measured at the parting line, mold flash or protrusions shall not exceed 0.20 mm per side. 2. Dimension “b” does not include dambar protrusion/intrusion. Allowable dambar protrusion shall be 0.13 mm total in excess of “b” dimension at maximum material condition. Dambar intrusion shall not reduce dimension “b” by more than 0.07 mm at least material condition. 3. These dimensions apply to the flat section of the lead between 0.10 and 0.25 mm from lead tips. 48 DS755F3 CS5532/34-BS 24 PIN SSOP PACKAGE DRAWING N D E11 A2 E e b2 SIDE VIEW A1 A ∝ L END VIEW SEATING PLANE 1 2 3 TOP VIEW INCHES DIM A A1 A2 b D E E1 e L ∝ MIN -0.002 0.064 0.009 0.311 0.291 0.197 0.024 0.025 0° MAX 0.084 0.010 0.074 0.015 0.335 0.323 0.220 0.027 0.040 8° MILLIMETERS MIN MAX -2.13 0.05 0.25 1.62 1.88 0.22 0.38 7.90 8.50 7.40 8.20 5.00 5.60 0.61 0.69 0.63 1.03 0° 8° NOTE 2,3 1 1 Notes: 1. “D” and “E1” are reference datums and do not included mold flash or protrusions, but do include mold mismatch and are measured at the parting line, mold flash or protrusions shall not exceed 0.20 mm per side. 2. Dimension “b” does not include dambar protrusion/intrusion. Allowable dambar protrusion shall be 0.13 mm total in excess of “b” dimension at maximum material condition. Dambar intrusion shall not reduce dimension “b” by more than 0.07 mm at least material condition. 3. These dimensions apply to the flat section of the lead between 0.10 and 0.25 mm from lead tips. DS755F3 49 CS5532/34-BS Revisions REVISION DATE CHANGES F1 Nov 2006 Initial Release. F2 MAY 2007 Corrected title to include 24-bit devices only. F3 OCT 2008 Changed Input Current to 1200 pA. Contacting Cirrus Logic Support For all product questions and inquiries contact a Cirrus Logic Sales Representative. To find the one nearest to you go to www.cirrus.com IMPORTANT NOTICE Cirrus Logic, Inc. and its subsidiaries ("Cirrus") believe that the information contained in this document is accurate and reliable. However, the information is subject to change without notice and is provided "AS IS" without warranty of any kind (express or implied). Customers are advised to obtain the latest version of relevant information to verify, before placing orders, that information being relied on is current and complete. All products are sold subject to the terms and conditions of sale supplied at the time of order acknowledgment, including those pertaining to warranty, indemnification, and limitation of liability. No responsibility is assumed by Cirrus for the use of this information, including use of this information as the basis for manufacture or sale of any items, or for infringement of patents or other rights of third parties. This document is the property of Cirrus and by furnishing this information, Cirrus grants no license, express or implied under any patents, mask work rights, copyrights, trademarks, trade secrets or other intellectual property rights. Cirrus owns the copyrights associated with the information contained herein and gives consent for copies to be made of the information only for use within your organization with respect to Cirrus integrated circuits or other products of Cirrus. This consent does not extend to other copying such as copying for general distribution, advertising or promotional purposes, or for creating any work for resale. CERTAIN APPLICATIONS USING SEMICONDUCTOR PRODUCTS MAY INVOLVE POTENTIAL RISKS OF DEATH, PERSONAL INJURY, OR SEVERE PROPERTY OR ENVIRONMENTAL DAMAGE ("CRITICAL APPLICATIONS"). CIRRUS PRODUCTS ARE NOT DESIGNED, AUTHORIZED OR WARRANTED FOR USE IN PRODUCTS SURGICALLY IMPLANTED INTO THE BODY, AUTOMOTIVE SAFETY OR SECURITY DEVICES, LIFE SUPPORT PRODUCTS OR OTHER CRITICAL APPLICATIONS. INCLUSION OF CIRRUS PRODUCTS IN SUCH APPLICATIONS IS UNDERSTOOD TO BE FULLY AT THE CUSTOMER'S RISK AND CIRRUS DISCLAIMS AND MAKES NO WARRANTY, EXPRESS, STATUTORY OR IMPLIED, INCLUDING THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR PARTICULAR PURPOSE, WITH REGARD TO ANY CIRRUS PRODUCT THAT IS USED IN SUCH A MANNER. IF THE CUSTOMER OR CUSTOMER'S CUSTOMER USES OR PERMITS THE USE OF CIRRUS PRODUCTS IN CRITICAL APPLICATIONS, CUSTOMER AGREES, BY SUCH USE, TO FULLY INDEMNIFY CIRRUS, ITS OFFICERS, DIRECTORS, EMPLOYEES, DISTRIBUTORS AND OTHER AGENTS FROM ANY AND ALL LIABILITY, INCLUDING ATTORNEYS' FEES AND COSTS, THAT MAY RESULT FROM OR ARISE IN CONNECTION WITH THESE USES. Cirrus Logic, Cirrus, and the Cirrus Logic logo designs are trademarks of Cirrus Logic, Inc. All other brand and product names in this document may be trademarks or service marks of their respective owners. SPI is a trademark of Motorola, Inc. Microwire is a trademark of National Semiconductor Corporation. 50 DS755F3