CLAIREX CLR131W

®
CLR130W,CLR131W,CLR132W
NPN Silicon Photodarlingtons

Technologies, Inc.
CLR130W, CLR131W, and CLRW132 are
exact replacements for obsolete part numbers
CLR2049, CLR2050 and CLR2060.
0.190 (4.83)
0.176 (4.47)
Clairex
April, 2002
0.500 (12.7) min
0.210 (5.33)
0.190 (4.83)
0.215 (5.46)
0.205 (5.21)
COLLECTOR
0.160 (4.06)
0.150 (3.81)
BASE
EMITTER
0.100 (2.54) dia
0.010 (0.25)
max
0.025 (0.64)
max
0.147 (3.73)
0.137 (3.48)
0.019 (0.48)
0.016 (0.41)
ALL DIMENSIONS ARE IN INCHES
(MILLIMETERS)
Case
18
features
absolute maximum ratings (TA = 25°C unless otherwise stated)
storage temperature........................................................................-65°C to +150°C
• high sensitivity
operating temperature ....................................................................-65°C to +125°C
• ±35° acceptance angle
lead soldering temperature(1) ..........................................................................260°C
• TO-18 hermetically sealed package
collector-emitter voltage .................................................................................... 15V
• transistor base is bonded
continuous collector current ........................................................................... 50mA
• RoHS compliant
continuous power dissipation(2) ....................................................................250mW
description
The CLR130W-CLR132W series are notes:
1. 0.06” (1.5mm) from the header for 5 seconds maximum
NPN silicon photodarlingtons
2. Derate linearly 2.0mW/°C from 25°C free air temperature to TA = +125°C.
mounted in TO-18 flat window
packages. The wide acceptance
angle provided by the flat window
enables even reception over a
relatively large area.
Photodarlingtons allow high
sensitivity at low irradiance levels
These devices are mechanically
and spectrally matched to the
CLE130-CLE133 series IREDs. For
additional information, call Clairex.
electrical characteristics (TA = 25°C unless otherwise noted)
symbol
parameter
min
typ
max
units
Collector dark current
0.2
0.6
1.4
-
-
100
mA
mA
mA
nA
Collector-emitter breakdown
15
-
-
V
IC=100µA
Output rise time
-
100
-
µs
VCE=5V, RL=100Ω.
Output fall time
-
150
-
µs
VCE=5V, RL=100Ω.
Total angle at half sensitivity points
-
70
-
deg.
Light current(1)
IL
ICEO
V(BR)CEO
tr
tf
θHP
CLR130W
CLR131W
CLR132W
test conditions
VCE=5V, Ee=0.06mW/cm2
VCE=10V, Ee=0
note: 1. Radiation source for all light current testing is a 940nm IRED.
Clairex reserves the right to make changes at any time to improve design and to provide the best possible product.
Clairex Technologies, Inc.
Phone: 972-265-4900
1301 East Plano Parkway
Fax: 972-265-4949
Revised 3/13/06
Plano, Texas 75074-8524
www.clairex.com