Disconnects Section Contents Page RED indicates NEW information 307 Disconnects Safety Module™ fused disconnect switch . . . . . 308-309 Coordination Module™ fused lighting and appliance panelboard . . . . . . . . . . . . . . . . . . . . . . 310-311 Power Module™ — all-in-one elevator disconnect . . . . . . . . . . . . . . . . . . . . . . . 312-313 Fusible disconnects Overview for compact series . . . . . . . . . . . . . . . . . . . . . . . 314 30A Base & DIN rail mount compact series switches . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 315-316 60-100A Base & DIN rail mount compact series switches . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 317 Accessories for 60-100A compact series switches . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 318 200-800A Base & DIN rail mount compact series switches . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 319-320 30–800A, 600V 3-Pole compact series enclosed switches . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 321-322 30–800A 2-, 4- & 6-Pole compact series enclosed switches . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 323-324 Non-fusible disconnects Overview for compact series non-fusible switches 16-125A . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 325 Overview for compact series non-fusible switches 175-3150A . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 326 16-100A compact series Base & DIN rail mount switches . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 327-328 16-100A compact series door mounted switches . . . . . 329 400-800A compact series non-fusible switches . . . . . . . 330 Accessories for 400-800A compact series switches . . . . 331 16–80A, 600V 3-Pole compact series non-fusible enclosed switches . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 332 16A-3150A, 600V 3-Pole compact series non-fusible enclosed switches . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 333 16-400A 2-, 4- & 6-Pole compact series non-fusible enclosed switches . . . . . . . . . . . . . . . . . . . . . . . . . . . 334-335 A/C Disconnects — fused and non-fused . . . . . . . . . .336 Fused, dead front disconnect switches . . . . . . . . . . . 337 Disconnects Safety Module™ fused disconnect switch SM363 _ _ Cooper Bussmann® Safety Module™ Specifications Description: A fused disconnect featuring enhanced safety features and use of the Cooper Bussmann® CUBEFuse®. Optional rejection kits prevent overfusing 30 and 60 amp circuits. Padlockable handle and door interlock provide safety during maintenance procedures. Viewing window permits viewing CUBEFuse permanent fuse indication status without opening the door. Poles: 3 Enclosures: NEMA 1, 3R, 12 and 4X Ratings: Volts: — 600Vac Amps: — 0-100A SCCR: — 50kA Agency Information: CE, UL Listed and cUL Listed. Features and Benefits • easyID™ fuse viewing window allows maintenance personnel to quickly identify open fuses — without opening the enclosure. • Wide amp range in one unit provides installation flexibility — one Safety Module™ covers 1-100A applications. • Rejection kits prevent overfusing 30A and 60A circuits. • Optional internal safety barrier covers all energized parts to provide added protection against electrical hazards — even with the enclosure door open. • • • • Accessories Optional internal safety barriers Solid neutral terminal Auxiliary contacts Rejection kits for 30 and 60 amp applications Catalog Numbers Catalog Numbers* SM363FG SM363FR SM363FD SM363FX Amp Rating 100 100 100 100 NEMA Enclosure 1 3R 12 4XSS Max. Hp Rating 240V 480V 600V 20 40 50 20 40 50 20 40 50 20 40 50 Dimensions (in)** Height Width Depth 16 8 5 16 12 5 16 10 6 16 12 6 SCCR 50kA 50kA 50kA 50kA * For safety barrier/rejection plate, add the suffix “B” to the catalog number, then add either; 1 for 30A, 2 for 60A or 3 for 100A. Example: SM363FGB3. NEMA 1 enclosures also available in gray. To order, place suffix “G” to the end of catalog number. Example: SM363FGG. NEMA 3R & 12 only available in gray. ** Does not include mounting tabs or handle. See Data Sheet for full dimensional data. 308 For product data sheets, visit www.cooperbussmann.com/products/datasheet.asp Disconnects Safety Module™ fused disconnect switch High Visibility Safety Yellow Easy to locate and identify disconnect means. Also available in standard gray. Padlockable Handle With up to three padlocks to protect maintenance personnel. Door Interlock Prevents opening door while energized, but can be overridden for testing or inspection. Positive Opening Operation Contacts are opened and closed by a driven mechanism (not springs) so the switch cannot reach the “OFF” position unless the contacts are truly open. Optional Safety Barrier Covers energized parts to provide added protection against electrical hazards. CUBEFuse™ • Class J time-delay electrical performance. • easyID™ permanent replace fuse indication to quickly determine fuse condition. • Finger-safe test points allow testing voltage without exposure to energized conductors. Fuse Base Accepts 1-100A fuses (rejection kits available). NEMA 1, 3R, 12 & 4X Enclosures Meet most application requirements. Viewing Window Quick identification of fuse condition — without opening the door. Conduit Knockouts For easy installation. Field Installed Accessories • Solid Neutral terminal • Auxiliary contacts • Internal lockable handle • Rejection kit for 30 and 60 amp applications For product data sheets, visit www.cooperbussmann.com/products/datasheet.asp 309 Disconnects Coordination Module™ fused lighting and appliance panelboard Type EP Cooper Bussmann® Coordination Module™ Specifications Description: A fused lighting and appliance panelboard for branch circuit applications. Specifically designed to meet the 2005 NEC® Code requirements for selective coordination for Emergency, Legally Required Standby and Essential Electrical Systems per 700.27, 701.18, and 517.26 when properly coordinated with the upstream overcurrent protective device feeder. Circuits: 12, 24, 36, 42 Enclosure: NEMA 1 Ratings: Volts: — 120/208 or 277/480Vac Branch Circuit Amps: — 0-30A SCCR: — 100kA Agency Information: UL67, UL 50. Features and Benefits • Complies with the new 2005 NEC® Selective Coordination Requirements for Emergency, Legally Required Standby and Essential Electrical Systems per 700.27, 701.18, and 517.26 when properly coordinated with the upstream overcurrent protective device feeder. Per the 2005 NEC®: Coordination (Selective) is the localization of an overcurrent condition to restrict outages to the circuit or equipment affected, accomplished by the choice of overcurrent protective devices and their ratings or settings. • Ensures system uptime with the goal of safety of human life during emergencies or for essential health care functions. • Provides a fast and easy solution to meeting new coordination Code requirements. Simply utilize published fuse selective coordination ratios to select the correct upstream fuse ratings. • Offers significant savings compared to other fused panels and selectively coordinated circuit breaker systems. Typical Applications • Hospitals • Schools • Commercial and industrial facilities Catalog Numbers Catalog Numbers EP2M23012GCC EP2M23024GCC EP2M23036GCC EP2M23042GCC EP4M23012GCC EP4M23024GCC EP4M23036GCC EP4M23042GCC Coordination Module* Voltage Rating SCCR 120/208 100kA** 120/208 100kA** 120/208 100kA** 120/208 100kA** 277/480 100kA*** 277/480 100kA*** 277/480 100kA*** 277/480 100kA*** Dimensions (in) Height Width Depth 36 28 5 3⁄4 38 28 5 3⁄4 48 28 5 3⁄4 48 28 5 3⁄4 36 28 5 3⁄4 36 28 5 3⁄4 48 28 5 3⁄4 48 28 5 3⁄4 Type MLO MLO MLO MLO MLO MLO MLO MLO Main Device Amp Rating 200 200 200 200 200 200 200 200 * Meets UL 67 (Panelboards) and UL 50 (Cabinets and Boxes). ** When protected by upstream LPN-RK 100A max. LPJ 200A max. or JJN 200A max., otherwise 10kA. *** When protected by upstream LPN-RK 200A max. LPJ 200A max. or JJN 200A max., otherwise 14kA. 310 For product data sheets, visit www.cooperbussmann.com/products/datasheet.asp Branch Circuit Amp Number of Rating Circuits 30 12 30 24 30 36 30 42 30 12 30 24 30 36 30 42 Disconnects Coordination Module™ fused lighting and appliance panelboard NEMA Type 1 Enclosure With surface mount trim. Ground Bar Bolted with set screw terminations. 120/208V or 277/480V Main Lugs With AGW 6-300Kcmil terminations. Full-Sized Neutral Bar With set-screw terminations. Class CC Fuse Holders With easyID Neon Indicator Provides ease of coordination with superior overcurrent protection and open fuse indication. 12 to 42 Circuits Branch Circuit Breakers Provide circuit isolation. 200A Copper Main Bus Data Sheet: 1154 For product data sheets, visit www.cooperbussmann.com/products/datasheet.asp 311 Disconnects Power Module™ — all-in-one elevator disconnect PS Power Module™ Switch for single elevator applications PS & PMP Cooper Bussmann® Power Module™ Specifications Description: Fusible power switch with shunt trip and fire safety interface to allow for single point tie in with fire alarm system. Ratings: Volts: — 600Vac, 3Ø Amps: — 30-400A (PS) — 30-400A (PMP feeder switches) — 400-800A (PMP main switches*) SCCR: — 200,000A rms *Contact Cooper Bussmann for applications greater than 800A. Agency Information: Complies with NFPA 70 (NEC®; National Electrical Code®), ANSI/ASME A17.1 (Safety Code for Elevators and Escalators), NFPA 72 (National Fire Alarm Code®) — Power Module Switch; UL Listed (UL 98) Enclosed and Dead front switch Guide 96NK3917, File E182262, NEMA 1, UL 50 Listed enclosure**, ULc per Canadian Standards C22.2, No. 0-M91-CAN/CSA C22.2, No. 4-M89 Enclosed switch. PMP Power Module™ Panel for multiple elevator applications **NEMA 12, 3R, and 4 enclosures also available — Power Module Panel; UL Listed (UL 67) Panel Boards or (UL 891) Dead Front Switchboard, File E181664, ULc per Canadian Standards, Service Entrance Rated. Features and Benefits • Internally powered, relay activated shunt trip system. • Mechanically interlocked auxiliary contact. • Self-contained adherence to elevator consensus standards, NFPA 70 (NEC®). NFPA 72, ANSI/ASME 17.1. Typical Applications • Elevator Disconnects • Computer Room Shunt Trip Disconnect • Fire Safety Interface Relay Accessories • For added safety, use the Cooper Bussmann SAMI™ fuse covers to improve maintenance personnel protection (OSHA 1910.333, paragraph C). Ordering The Cooper Bussmann Power Module switch and panel are factory configured to the specific application. Contact your Cooper Bussmann representative to place your order. Have all relevant electrical and circuit information on hand. PS Data Sheet: 1145 312 PMP Data Sheet: 1146 For product data sheets, visit www.cooperbussmann.com/products/datasheet.asp Disconnects Power Module™ — all-in-one elevator disconnect The Power Module™ is the best choice for design engineers or electrical contractors that need to meet these requirements, Codes and standards: • Elevator Shutdown – ANSI/ASME A17.1 Rule 102.2(c)(3) • Shunt Trip Voltage Monitoring – NFPA 72-1999 3-9.4.4 • Integrity Monitoring – NFPA 72-1999 3-9.2.1 • Allows Elevator Shutdown – NEC® 620.51 • Selective Coordination – NEC® 620.62 • Auxiliary Contact (Hydraulic Elevator) – NEC® 620.91(C) • Orderly Shutdown – NEC® 240.12 With the Power Module You Get: • Shunt trip capability • Selective coordination • Fire safety signal interface • Shunt trip voltage monitoring • Component protection via Low-Peak® Class J fuses • UL 98 Listed for 200kA short-circuit current rating • Lockable in the open position with three lock capability • Optional key-test switch and optional pilot light for easy inspection • No annual calibration or testing of overcurrent protection required • Padlockable for service work safety and open door “override” for troubleshooting Notes: A lways follow established safety practices when wo rking on a electrically live equipment. Hydraulic Elevators need battery backup to help prevent stranding passengers. To keep the elevator from moving when it’s been manually shut down for maintenance, the NEC® requires battery backup be connected to the elevator disconnecting means through an auxillary contact. However, an unintended consequence can be passengers getting stranded because of devices that open automatically (circuit breakers and disconnects utilizing a Scenario Power failure Fire in shaft or machine room Disconnect manually opened Fault on loadside of disconnect Battery Lowering Required Yes No No molded case switch with a trailing fuse block) will operate with a fault on their loadside. That operation also disables the battery backup and strands passengers. That’s why the Power Module has a non-automatic fusible shunt trip switch. If the Power Module has a fault on its loadside, the fuses open and the battery stays enabled. Thus the Power Module ensures that battery power is enabled when the passengers need it to exit, and disabled to allow safe maintenance of the elevator and hoistway. Reason Need to lower elevator to allow passengers to exit Recall is initiated by smoke detector and lowers elevator to a safe floor. Battery not needed Worker to perform maintenance. Elevator must remain stationary to prevent injury Need to lower elevator to allow passengers to exit Offered By Power Module™ Yes Offered By Other Elevator Disconnects Yes Yes Yes Yes Yes Yes No Yes For product data sheets, visit www.cooperbussmann.com/products/datasheet.asp 313 Disconnects Hydraulic Elevators Power Module™ Panel (PMP) Disconnects Overview for compact series fusible disconnect switches CFD30CC3 to FD800L3 CFD60J3 FD400J3 CFD100J3 Agency Information: UL listed, CSA certified, IEC rated, CE marked. Catalog Numbers 3-pole CFD30CC3 CFD30J3 CFD60J3 CFD100J3 FD200J3 FD400J3 FD600J3 FD800L3 A 30 30 60 100 200 400 600 800 2-pole 3-pole 4-pole N/A UL98 & IEC UL98 & IEC N/A UL98 & IEC UL98 & IEC N/A UL98 & IEC UL98 & IEC UL98 & IEC UL98 & IEC UL98 & IEC UL98 & IEC UL98 & IEC UL98 & IEC UL98 & IEC UL98 & IEC UL98 & IEC UL98 & IEC UL98 & IEC UL98 & IEC UL98 & IEC UL98 & IEC UL98 & IEC 600 600 600 600 600 600 600 600 hp hp hp hp hp hp 5/7.5 7.5 15 20 2 3 CC 5/7.5 7.5 15 20 2 3 J 15 15 30 50 — — J 25 30 60 75 — — J 50 60 125 150 — — J,T 100/125 125 250 350 — — J,T 150 200 400 500 — — J,T 200 250 500 600 — — L kA A 200 30 J/CC 200 30 J 200 60 J/T 200 100 J/T 200 200 J/T 200 400 J/T 200 600 J/T 200 800 L General Purpose Amp Ratings Approvals(1) Technical Ratings (UL,CSA) Max operating voltage Max horsepower rating Three phase Single phase V 200-208V 240V 480V 600V 120V 240V UL fuse class Short-circuit rating with fuses UL fuse size UL fuse type Technical Ratings (IEC) Rated insulation and operational voltage. ac20 and dc20(2) Rated thermal current, Ith ac 20/dc 20 open ac 20/dc 20 enclosed ac 21A ≤500V ≤690V Rated operational power ac 23 400/415V 690V 1000 1000 750 750 1000 1000 1000 1000 A A A A 32 32 32 32 32 32 32 32 63 63 63 63 125 125 125 125 250 250 250 250 400 400 400 400 630 600 630 630 800 720 800 800 kW kW 14/15 25 14/15 25 30 60 80/90 132 132/140 230 210/230 330 315/340 540 350/380 600 lb lb H in W in D in 1.54 1.98 3.82 4.17 4.21 1.54 1.98 3.82 4.17 4.21 2.86 3.52 3.94 5.63 5.04 3.30 3.96 5.66 7.06 5.09 15.21 17.4 7.87 10.31 7.83 17.2 19.4 7.87 11.22 8.11 37.48 46.3 11.42 14.69 9.21 Physical Characteristics Weight Dimension 3-pole switch 4-pole 3-pole (1) UL listed switches are also CSA certified (2) 1000V IEC 408 314 For product data sheets, visit www.cooperbussmann.com/products/datasheet.asp 37.48 46.3 11.42 14.69 9.21 Disconnects 30A Base & DIN rail mount compact series fusible disconnect switches Handle - Selector 30A UL fuse Class J, CC For a complete assembly, please select one of each: • 1 switch • 1 shaft • 1 handle 30A/600V Switches Catalog Numbers CFD30J3 CFD30CC3 CFD30J4 CFD30CC4 UL General Purpose Poles Amp Rating 3 30 3 30 4 30 4 30 Fuse Type 600V J CC J CC Maximum Horsepower Rating Three Phase 200V 208V 240V 480V 600V 5 7.5 7.5 15 20 5 7.5 7.5 15 20 5 7.5 7.5 15 20 5 7.5 7.5 15 20 Terminal Lugs Wire Size/Type #18 – 8/CU #18 – 8/CU #18 – 8/CU #18 – 8/CU CFD30J3 Shafts — For use with CDH selector handles 0.20 x 0.20" ( 5 x 5 mm) Catalog Numbers CDS85S CDS105S CDS120S CDS130S CDS180S CDS250S CDS330S Shaft Length in (mm) 3.3 (85) 4.1 (105) 4.7 (120) 5.1 (130) 7.1 (180) 9.8 (250) 13.0 (330) Mounting Depth(1) in inches 5.5-5.7 5.5-6.5 5.5-7.1 5.5-7.5 6.3-9.4 9.1-12.2 12.2-15.4 (1) Mounting depth is the distance from the outside of the door to the disconnect switch mounting plate. Shaft can be cut to desired length. Catalog Numbers CDH3S CDH4S CDH5S CDH6S NEMA Type 1,3R,12 1,3R,12 1,3R,12 1,3R,12 IEC Type IP65 IP65 IP65 IP65 Color Black Red/Yellow Black Red/Yellow Defeatable — — Yes Yes CDS_ _S Disconnects Handle - Selector — For use with shafts 0.20 x 0.20" ( 5 x 5 mm) All marked both O/I & Off/On Padlockable Yes Yes Yes Yes CDH4S, 6S For product data sheets, visit www.cooperbussmann.com/products/datasheet.asp 315 Disconnects 30A Base & DIN rail mount compact series fusible disconnect switches Handle - Pistol 30A UL fuse Class J, CC For a complete assembly, please select one of each: • 1 switch • 1 shaft • 1 handle Switches 30A/600V Catalog Numbers CFD30J3 CFD30CC3 CFD30J4 CFD30CC4 UL General Purpose Poles Amp Rating 3 30 3 30 4 30 4 30 Fuse Type 600V J CC J CC Maximum Horsepower Rating Three Phase 200V 208V 240V 480V 600V 5 7.5 7.5 15 20 5 7.5 7.5 15 20 5 7.5 7.5 15 20 5 7.5 7.5 15 20 Terminal Lugs Wire Size/Type #18 – 8/CU #18 – 8/CU #18 – 8/CU #18 – 8/CU Shafts For use with pistol handles 0.20 x 0.20" ( 5 x 5 mm) Catalog Number CDS48P CDS67P CDS49P CDS50P CDS99P Shaft length in (mm) 5.9 (150) 6.7 (170) 10.4 (265) 15.8 (400) 19.7 (500) CFD30J3 Mounting Depth (1) in inches 4.9-8.9 5.9-9.7 9.5-13.4 15.0-18.7 20.5-22.6 (1) Mounting depth is the distance from the outside of the door to the disconnect switch mounting plate. Shaft can be cut to desired length. Handles - Pistol For use with shafts 0.20 x 0.20" ( 5 x 5 mm) Catalog Numbers BDH104 BDH105 BDH106 BDH107 CDHXB65 CDHXY65 BDH106T BDH107T NEMA Type 1,3R,12 1,3R,12 1,3R,12 1,3R,12 1,3R,4,4X,12 1,3R,4,4X,12 1,3R,12 1,3R,12 IEC Type IP65 IP65 IP65 IP65 IP65 IP65 IP65 IP65 Color Black Red/Yellow Black Red/Yellow Black Red/Yellow Black Red/Yellow CDS__ __P Length in (mm) 1.8 (45) 1.8 (45) 2.6 (65) 2.6 (65) 2.6 (65) 2.6 (65) 2.6 (65) 2.6 (65) Marking O/I&Off/On O/I&Off/On O/I&Off/On O/I&Off/On O/I&Off/On O/I&Off/On Off/On/Test Off/On/Test Defeatable Yes Yes Yes Yes Yes Yes Yes Yes Padlockable Yes Yes Yes Yes Yes Yes Yes Yes Handle - Direct Mount Mounts directly to switch, no shaft necessary Catalog Number BDH79 NEMA Type 1 Color Black Marking O/I/Test Length in (mm) 5.2 (132) Padlockable Yes 5.20" BDH79 BDH79 Mounted 316 BDH104, 106 132mm 5.20"/132mm BDH79 Mounted Depth For product data sheets, visit www.cooperbussmann.com/products/datasheet.asp Disconnects 60-100A Base & DIN rail mount compact series fusible disconnect switches Handle - Pistol 60-100A UL fuse Class J • • • • For a complete assembly, please select one of each: 1 switch 1 shaft 1 handle 1 terminal lug kit Switches 60—100A/600V Catalog Number CFD60J3 CFD100J3 CFD60J4 CFD100J4 Poles 3 3 4 4 UL General UL Fuse Purpose Type Amp Rating 600V 60 J 100 J 60 J 100 J 200V 15 25 15 25 Maximum Horsepower Rating Three Phase 208V 240V 480V 600V 15 15 30 50 25 30 60 75 15 15 30 50 25 30 60 75 Shafts — 0.24 x 0.24" ( 6 x 6 mm) Catalog Numbers BDS150 BDS210 BDS290 BDS360 BDS430 Shaft Length in (mm) 5.9 (150) 8.3 (210) 11.4 (290) 14.2 (360) 16.9 (430) Mounting Depth (1) in inches 5.5-8.5 8.0-11.0 11.0-14.0 13.8-16.8 16.5-19.7 CFD60J (1) Mounting depth is the distance from the outside of the door to the disconnect switch mounting plate. Shaft can be cut to desired length. Shafts - Twisted Rotates handle 45° 0.24 x 0.24" ( 6 x 6 mm) Catalog Numbers BDST4 BDST25 BDST29 BDST30 Shaft Length in (mm) 5.1 (130 8.3 (210 11.4 (290 14.2 (360 Mounting Depth (1) in inches 4.8-7.8 8.0-11.0 11.0-14.0 13.8-16.8 (1) Mounting depth is the distance from the outside of the door to the disconnect switch mounting plate. Shaft can be cut to desired length. Disconnects BDS__ Handles - Pistol — 0.24 x 0.24" ( 6 x 6 mm) Catalog Numbers BDH58 BDH59 BDH60 BDH61 CDHXB86 CDHXY86 NEMA Type 1,3R,12 1,3R,12 1,3R,12 1,3R,12 1,3R,4,4X,12 1,3R,4,4X,12 IEC Type IP65 IP65 IP65 IP65 IP65 IP65 Color Black Red/Yel Black Red/Yel Black Red/Yel Length in (mm) 2.6 (65) 2.6 (65) 3.1 (80) 3.1 (80) 3.1 (80) 3.1 (80) Marking O/I & Off/On O/I & Off/On O/I & Off/On O/I & Off/On O/I & Off/On O/I & Off/On Defeatable Yes Yes Yes Yes Yes Yes Padlockable Yes Yes Yes Yes Yes Yes Direct Mount Handle Mounts directly to switch, no shaft necessary Catalog Number CDH4 NEMA Type 1 Color Black Marking O/I/Test Length(mm) 50 Padlockable Yes BDH59, 61 For product data sheets, visit www.cooperbussmann.com/products/datasheet.asp 317 Disconnects Accessories for 60-100A compact series fusible disconnect switches Terminal Lug Kit Catalog Numbers Integral BDTL24 For Use On: CFD60J_ CFD100J_ Wire Type CU CU/AL Wire Size #14-4 #14-2/0 Terminal Lugs Per Kit — 6 BDTL24 Auxiliary Contacts Catalog Numbers CDAUX10 CDAUX01K Description 1 NO 1 NC For Use On: CFD60 – CFD100 AC Thermal Amp Rating 10 10 AC Rated Voltage 600 600 CDAUX10 CDAUX01K Replacement Fuse Clip Catalog Number CFC60J Description Removable fuse carrier For Use On: CFD60 CFC60J Replacement Fuse Covers Catalog Number CFCVR100 Description Transparent fuse cover For Use On: CFD100 CFCVR100 Terminal Shroud Catalog Number CFTS100 Description Includes one terminal shroud for line or load side For Use On: CFD100, 1-Pole CFTS100 Terminal Poles Catalog Numbers CFZ1 CFZ2 Description Detachable neutral mounts on side of switch or DIN rail For Use On: CFD60 CFD100 AC Thermal AC Rated Amp Rating Voltage 63 600 125 CFZ1 DIN Rail Catalog Numbers NDNA100 Description 35mm Aluminum DIN Rail For Use On: CFD60 Length in(cm) 39.4 (100) NDNA100 “T” Type Fuse Adapter Kit Catalog Number BDTA1 Description 100A, 600V For Use On: CFD100 BDTA1 318 For product data sheets, visit www.cooperbussmann.com/products/datasheet.asp Disconnects 200-800A Base & DIN rail mount compact series fusible disconnect switches Handle - Pistol 200-800A UL fuse Class J, T, L • • • • For a complete assembly, please select one of each: 1 switch 1 shaft 1 handle 1 terminal lug kit Switches 200—800A, 600V Catalog Number FD200J2 FD400J2 FD600J2 FD800L2 FD200J3 FD400J3 FD600J3 FD800L3 FD200J4 FD400J4 FD600J4 FD800L4 Poles 2 2 2 2 3 3 3 3 4 4 4 4 UL General UL Fuse Purpose Type Amp Rating 600V 200 J(1) 400 J(1) 600 J(1) 800 L 200 J(1) 400 J(1) 600 J(1) 800 L 200 J(1) 400 J(1) 600 J(1) 800 L 200V — — — — 50 100 150 200 50 100 150 200 Maximum Horsepower Rating Three Phase 208V 240V 480V 600V — — — — — — — — — — — — — — — — 50 60 125 150 125 125 250 350 150 200 400 500 200 250 500 600 50 60 125 150 125 125 250 350 150 200 400 500 200 250 500 600 FD600J3 FD800L3 (1) J type fuse clips are standard. If 600V Type “T” clips are desired, please order a "T" type fuse adapter kit. Shafts — 0.47 x 0.47" ( 12 x 12 mm) Catalog Number Shaft Length in (mm) Mounting Depth(1) in inches For use on FD200J_ – FD400J_ BDS220 BDS250 BDS280 BDS325 BDS395 BDS465 BDS535 8.7 9.8 11.0 12.8 15.6 18.3 21.1 (220) (250) (280) (325) (395) (465) (535) 7.9-12.2 9.1-13.4 10.2-14.5 12.0-16.3 14.8-19.1 17.5-21.9 20.3-24.6 BDS_ Disconnects For use on FD600J_ – FD800J_ BDS250 BDS280 BDS325 BDS395 BDS465 BDS535 9.8 11.0 12.8 15.6 18.3 21.1 (250) (280) (325) (395) (465) (535) 10.0-12.8 11.2-14.0 13.0-15.8 15.8-18.6 18.5-21.3 21.1-24.1 (1) Mounting depth is the distance from the outside of the door to the disconnect switch mounting plate. Shaft can be cut to desired length. BDH114 Shafts - Twisted Rotates handle 45° 0.47 x 0.47" ( 12 x 12 mm) Catalog Number Shaft Length in (mm) Mounting Depth (1) in inches For use on FD200J_ – FD400J_ BDS28045 BDS32545 BDS46545 11.0 (280) 12.8 (325) 18.3 (465) 10.2-14.5 12.0-16.3 17.5-21.9 For use on FD600J_ – FD800J_ BDS28045 BDS32545 BDS46545 11.0 (280) 12.8 (325) 18.3 (465) 11.2-14.0 13.0-15.8 18.5-21.3 (1) Mounting depth is the distance from the outside of the door to the disconnect switch mounting plate. Shaft can be cut to desired length. BDTL25 For product data sheets, visit www.cooperbussmann.com/products/datasheet.asp 319 Disconnects 200-800A Base & DIN rail mount compact series fusible disconnect switches Handles - Pistol — 0.47 x 0.47" ( 12 x 12 mm) Catalog Numbers BDH112 BDH113 BDH114 BDH115 BDH116 BDH117 CDHXB12 CDHXY12 CDHXB22 CDHXY22 BDH8 NEMA Type 1,3R,12 1,3R,12 1,3R,12 1,3R,12 1,3R,12 1,3R,12 1,3R,4,4X,12 1,3R,4,4X,12 1,3R,4,4X,12 1,3R,4,4X,12 1,3R,4,4X,12 IEC Type IP65 IP65 IP65 IP65 IP65 IP65 IP65 IP65 IP65 IP65 IP65 Color Black Red/Yellow Black Red/Yellow Black Red/Yellow Black Red/Yellow Black Red/Yellow Metal Length in (mm) 4.9 (125) 4.9 (125) 5.7 (145) 5.7 (145) 6.9 (175) 6.9 (175) 5.7 (145) 5.7 (145) 6.9 (175) 6.9 (175) 8.7 (220) Marking O/I & Off/On O/I & Off/On O/I & Off/On O/I & Off/On O/I & Off/On O/I & Off/On O/I & Off/On O/I & Off/On O/I & Off/On O/I & Off/On Off/On Defeatable Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes — Padlockable Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes BDH112 Terminal Lug Kit Catalog Numbers BDTL25 BDTL175 BDTL26 BDTL175/400 BDTL27 For Use On: FD200J_ FD200J FD400J_ FD600J – FD800L FD600J_ & FD800L_ Wire Size #6 – 300 kcmil (6) #14 – 6 kcmil #2 – 600 kcmil (12) #14 – 16–600 kcmil (2) #2 – 600 kcmil Wire Type CU/AL CU/AL CU/AL CU/AL CU/AL Terminal Lugs Per Kit 6 3 6 3 6 BDTL175/400 “T” Type Fuse Adapter Kit Catalog Number BDTA2 BDTA4 BDTA6 BDTA8 Poles 3 3 3 3 For Use On: FD200J_ FD400J_ FD600J_ FD800J_ AC Thermal Amp Rating 200 400 600 800 AC Rated Voltage 600 600 600 600 BDTA Did You Know? Protect the Promise of Customer Satisfaction Our customer satisfaction team answers your calls 8:00 a.m. – 4:30 p.m. for all US time zones, receiving and responding to an average of 1600 calls and 700 emails every day. We also offer emergency after-hours service. Phone: 636-527-3877 email: [email protected] Toll-free fax: 800-544-2570 Emergency after-hour phone: 314-995-1342 320 For product data sheets, visit www.cooperbussmann.com/products/datasheet.asp Disconnects 30–800A, 600V 3-Pole enclosed compact series fusible disconnect switches Handle - Pistol NEMA 1, 3R, 4 and 4X, UL fuse Class J, CC EFJ30X-3PB6 Catalog Numbers UL General Purpose Amp Rating 30 30 60 100 200 400 600 800 Fuse Class/ Type J CC J(2) J(2) J(2) J(2) J(2) J(2) Catalog Numbers (1) NEMA/UL Enclosure Type 1 3R EFJ301-3PB6 EFJ303-3PB6 EFC301-3PB6 EFC303-3PB6 EFJ601-3PB6 EFJ603-3PB6 EFJ1001-3PB8 EFJ1003-3PB8 EFJ2001-3PB4 EFJ2003-3PB4 EFJ4001-3PB4 EFJ4003-3PB4 EFJ6001-3PB4 EFJ6003-3PB4 EFL8001-3PB4 EFL8003-3PB4 4 EFJ304-3PB6 EFC304-3PB6 EFJ604-3PB8 EFJ1004-3PB8 EFJ2004-3PB4 EFJ4004-3PB4 EFJ6004-3PB4 EFL8004-3PB4 4X Stainless EFJ30X-3PB6 EFC30X-3PB6 EFJ60X-3PB8 EFJ100X-3PB8 EFJ200X-3PB4 EFJ400X-3PB4 EFJ600X-3PB4 EFL800X-3PB4 (1) Fusible switches are UL listed to the UL98 standard. (2) 600V T type fuse clips may be substituted at no charge. Please change the second character of the catalog number from "J" to "T." Disconnects NEMA 4X, 12 and 7&9, UL fuse Class J, CC Catalog Numbers UL General Purpose Amp Rating 30 30 60 100 200 400 600 800 Fuse Class Type J CC J(2) J(2) J(2) J(2) J(2) J(2) Catalog Numbers (1) NEMA/UL Enclosure Type 4X Plastic 12 EFJ30P-3PB6 EFJ302-3PB6 EFC30P-3PB6 EFC302-3PB6 EFJ60P-3PB8 EFJ602-3PB6 EFJ100P-3PB8 EFJ1002-3PB8 EFJ200P-3PB4 EFJ2002-3PB4 EFJ400P-3PB4 EFJ4002-3PB4 EFJ600P-3PB4 EFJ6002-3PB4 EFL800P-3PB4 EFL8002-3PB4 7&9 EFJ307-3PB EFC307-3PB EFJ607-3PB EFJ1007-3PB EFJ2007-3PB EFJ4007-3PB EFJ6007-3PB EFL8007-3PB CFD30J3 (1) Fusible switches are UL listed to the UL98 standard. (2) 600V T type fuse clips may be substituted at no charge. Please change the second character of the catalog number from "J" to "T." For product data sheets, visit www.cooperbussmann.com/products/datasheet.asp 321 Disconnects 30–800A, 600V 3-Pole enclosed compact series fusible disconnect switches Switch Ratings UL General Maximum Purpose Single Phase Amp Rating 120V 200V 240V 30 2 3 5 60 3 7.5 10 100 5 10 15 200 — — — 400 — — — 600 — — — 800 — — — Horsepower Rating Three Phase 200V 208V 5 7.5 15 15 25 25 50 50 100 125 150 150 200 200 240V 7.5 15 30 60 125 200 250 480V 15 30 60 125 250 400 500 600V 20 50 75 150 350 500 600 Wire Size For Terminal Lugs #18 – 8 #14 – 4 #14 – 2/0 #6 – 300 kcmil #2 – 600 kcmil (2) #2 – 600 kcmil (2) #2 – 600 kcmil For Wire Type CU CU CU/AL CU/AL CU/AL CU/AL CU/AL Approval(1) CSA, UL CSA, UL CSA, UL CSA, UL CSA, UL CSA, UL CSA, UL (1) Fusible switches are UL listed to the UL98 standard. Handle Ratings Catalog Numbers CDH5S CDH6S BDH106 BDH107 CDHXB65 CDHXY65 BDH58 BDH59 BDH60 BDH61 CDHXB86 CDHXY86 BDH114 BDH115 BDH116 BDH117 CDHXB12 CDHXY12 CDHXB22 CDHXY22 BDH8 Catalog No. Suffix BJ YJ B6 Y6 B6 Y6 B6 Y6 B8 Y8 B8 Y8 B4 Y4 B7 Y7 B4 Y4 B7 Y7 8 Amp Range 30 30 30 30 30 30 60-100 60-100 60-100 60-100 60-100 60-100 200-800 200-800 200-800 200-800 200-800 200-800 200-800 200-800 200-800 Handle Type Selector Selector Pistol Pistol Pistol Pistol Pistol Pistol Pistol Pistol Pistol Pistol Pistol Pistol Pistol Pistol Pistol Pistol Pistol Pistol Pistol NEMA Rating 1,3R,12 1,3R,12 1,3R,12 1,3R,12 1,3R,4,4X,12 1,3R,4,4X,12 1,3R,12 1,3R,12 1,3R,12 1,3R,12 1,3R,4,4X,12 1,3R,4,4X,12 1,3R,12 1,3R,12 1,3R,12 1,3R,12 1,3R 4,4X,12 1,3R 4,4X,12 1,3R 4,4X,12 1,3R 4,4X,12 1,3R 4,4X,12 Color Black Red/Yel Black Red/Yel Black Red/Yel Black Red/Yel Black Red/Yel Black Red/Yel Black Red/Yel Black Red/Yel Black Red/Yel Black Red/Yel Metal Marking 0/I & Off/On 0/I & Off/On 0/I & Off/On 0/I & Off/On 0/I & Off/On 0/I & Off/On 0/I & Off/On 0/I & Off/On 0/I & Off/On 0/I & Off/On 0/I & Off/On 0/I & Off/On 0/I & Off/On 0/I & Off/On 0/I & Off/On 0/I & Off/On 0/I & Off/On 0/I & Off/On 0/I & Off/On 0/I & Off/On 0/I & Off/On Defeatable Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes No Padlockable Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Did You Know? Easy Internet Access to Product and Technical Information All of the following functions are available on-line at www.cooperbussmann.com: • Product cross-reference • Product catalogs • Technical specification sheets • Current events/news releases • Training seminar schedule • Training modules • Technical software solutions 322 For product data sheets, visit www.cooperbussmann.com/products/datasheet.asp Disconnects 30–800A 2-, 4- and 6-Pole enclosed compact series fusible disconnect switches NEMA 1, 3R and 4X for Transfer, Bypass and Mechanical Interlock Applications Catalog Numbers UL General Purpose Amp Rating 30 (Class J fuses) 30 (Class CC fuses) 60 100 200 400 800 1 EFJ301-4PB6 EFJ301-6PB6 EFJ301-3TB8 EFJ301-3BB6 EFJ301-3MB6 EFC301-4PB6 EFC301-6PB6 EFC301-3TB8 EFC301-3BB6 EFC301-3MB6 EFJ601-4PB6 EFJ601-6PB4 EFJ601-3TB8 EFJ601-3MB6 EFJ1001-2PB8 EFJ1001-4PB8 EFJ1001-6PB4 EFJ1001-3TB8 EFJ1001-3MB8 EFJ2001-2PB8 EFJ2001-4PB4 EFJ2001-6P8 EFJ2001-3TB4 EFJ2001-3B6 EFJ2001-3MB4 EFJ4001-2PB4 EFJ4001-4PB4 EFJ4001-6P8 EFJ4001-3TB4 EFJ4001-3B6 EFJ4001-3MB4 EFJ6001-2PB4 EFJ6001-4PB4 EFJ6001-6P8 EFJ6001-3TB4 EFJ6001-3B6 EFJ6001-3MB4 EFL8001-2PB4 EFL8001-4PB4 EFL8001-6P8 EFL8001-3TB4 EFL8001-3B6 EFL8001-3MB4 Catalog Numbers NEMA Enclosure Type 3R 4 EFJ303-4PB6 EFJ304-4PB6 EFJ303-6PB6 EFJ304-6PB6 EFJ303-3TB8 EFJ304-3TB8 EFJ303-3BB6 EFJ304-3BB6 EFJ303-3MB6 EFJ304-3MB6 EFC303-4PB6 EFC304-4PB6 EFC303-6PB6 EFC304-6PB6 EFC303-3TB8 EFC304-3TB8 EFC303-3BB6 EFC304-3BB6 EFC303-3MB6 EFC304-3MB6 EFJ603-4PB6 EFJ604-4PB6 EFJ603-6PB4 EFJ604-6PB4 EFJ603-3TB8 EFJ604-3TB8 EFJ603-3MB6 EFJ604-3MB6 EFJ1003-2PB8 EFJ1004-2PB8 EFJ1003-4PB8 EFJ1004-4PB8 EFJ1003-6PB4 EFJ1004-6PB4 EFJ1003-3TB8 EFJ1004-3TB8 EFJ1003-3MB8 EFJ1004-3MB8 EFJ2003-2PB8 EFJ2004-2PB8 EFJ2003-4PB4 EFJ2004-4PB4 EFJ2003-6P8 EFJ2004-6P8 EFJ2003-3TB4 EFJ2004-3TB4 EFJ2003-3B6 EFJ2004-3B6 EFJ2003-3MB4 EFJ2004-3MB4 EFJ4003-2PB4 EFJ4004-2PB4 EFJ4003-4PB4 EFJ4004-4PB4 EFJ4003-6P8 EFJ4004-6P8 EFJ4003-3TB4 EFJ4004-3TB4 EFJ4003-3B6 EFJ4004-3B6 EFJ4003-3MB4 EFJ4004-3MB4 EFJ6003-2PB4 EFJ6004-2PB4 EFJ6003-4PB4 EFJ6004-4PB4 EFJ6003-6P8 EFJ6004-6P8 EFJ6003-3TB4 EFJ6004-3TB4 EFJ6003-3B6 EFJ6004-3B6 EFJ6003-3MB4 EFJ6004-3MB4 EFL8003-2PB4 EFL8004-2PB4 EFL8003-4PB4 EFL8004-4PB4 EFL8003-6P8 EFL8004-6P8 EFL8003-3TB4 EFL8004-3TB4 EFL8003-3B6 EFL8004-3B6 EFL8003-3MB4 EFL8004-3MB4 4X Stainless EFJ30X-4PB6 EFJ30X-6PB EFJ30X-3TB8 EFJ30X-3BB6 EFJ30X-3MB6 EFC30X-4PB6 EFC30X-6PB6 EFC30X-3TB8 EFC30X-3BB6 EFC30X-3MB6 EFJ60X-4PB6 EFJ60X-6PB4 EFJ60X-3TB8 EFJ60X-3MB6 EFJ100X-2PB8 EFJ100X-4PB8 EFJ100X-6PB4 EFJ100X-3TB8 EFJ100X-3MB8 EFJ200X-2PB8 EFJ200X-4PB4 EFJ200X-6P8 EFJ200X-3TB4 EFJ200X-3B6 EFJ200X-3MB4 EFJ400X-2PB4 EFJ400X-4PB4 EFJ400X-6P8 EFJ400X-3TB4 EFJ400X-3B6 EFJ400X-3MB4 EFJ600X-2PB4 EFJ600X-4PB4 EFJ600X-6P8 EFJ600X-3TB4 EFJ600X-3B6 EFJ600X-3MB4 EFL800X-2PB4 EFL800X-4PB4 EFL800X-6P8 EFL800X-3TB4 EFL800X-3B6 EFL800X-3MB4 2-Pole 4-Pole 6-Pole Disconnects 600 Switch Type 4-Pole(1) 6-Pole Transfer Bypass Mech. interlock 4-Pole(1) 6-Pole Transfer Bypass Mech. interlock 4-Pole(1) 6-Pole Transfer Mech. interlock 2-Pole(1) 4-Pole(1) 6-Pole Transfer Mech. interlock 2-Pole(1) 4-Pole(1) 6-Pole Transfer Bypass Mech. interlock 2-Pole(1) 4-Pole(1) 6-Pole Transfer Bypass Mech. interlock 2-Pole(1) 4-Pole(1) 6-Pole Transfer Bypass Mech. interlock 2-Pole(1) 4-Pole(1) 6-Pole Transfer Bypass Mech. interlock (2) (1) IEC rated only. (2) = Three-poles For product data sheets, visit www.cooperbussmann.com/products/datasheet.asp 323 Disconnects 30–800A 2-, 4- and 6-Pole enclosed compact series fusible disconnect switches NEMA 4X, 12 and 7&9 for Transfer, Bypass and Mechanical Interlock Applications Catalog Numbers UL General Purpose Switch Amp Rating Type 30 (Class J fuses) 4-Pole(1) 6-Pole Transfer Bypass Mech. interlock 30 (Class CC fuses) 4-Pole(1) 6-Pole Transfer Bypass Mech. interlock 60 4-Pole(1) 6-Pole Transfer Mech. interlock 100 2-Pole(1) 4-Pole(1) 6-Pole Transfer Mech. interlock 200 2-Pole(1) 4-Pole(1) 6-Pole Transfer Bypass Mech. interlock 400 2-Pole(1) 4-Pole(1) 6-Pole Transfer Bypass Mech. interlock 600 2-Pole(1) 4-Pole(1) 6-Pole Transfer Bypass Mech. interlock 800 2-Pole(1) 4-Pole(1) 6-Pole Transfer Bypass Mech. interlock Catalog Numbers NEMA Enclosure Type 4X Plastic 12 EFJ30P-4PB6 EFJ302-4PB6 EFJ30P-6PB6 EFJ302-6PB6 EFJ30P-3TB8 EFJ302-3TB8 EFJ30P-3BB6 EFJ302-3BB6 EFJ30P-3MB6 EFJ302-3MB6 EFC30P-4PB6 EFC302-4PB6 EFC30P-6PB6 EFC302-6PB6 EFC30P-3TB8 EFC302-3TB8 EFC30P-3BB6 EFC302-3BB6 EFC30P-3MB6 EFC302-3MB6 EFJ60P-4PB6 EFJ602-4PB6 EFJ60P-6PB4 EFJ602-6PB4 EFJ60P-3TB8 EFJ602-3TB8 EFJ60P-3MB6 EFJ602-3MB6 EFJ100P-2PB8 EFJ1002-2PB8 EFJ100P-4PB8 EFJ1002-4PB8 EFJ100P-6PB4 EFJ1002-6PB4 EFJ100P-3TB8 EFJ1002-3TB8 EFJ100P-3MB8 EFJ1002-3MB8 EFJ200P-2PB8 EFJ2002-2PB8 EFJ200P-4PB4 EFJ2002-4PB4 EFJ200P-6P8 EFJ2002-6P8 EFJ200P-3TB4 EFJ2002-3TB4 EFJ200P-3B6 EFJ2002-3B6 EFJ200P-3MB4 EFJ2002-3MB4 EFJ400P-2PB4 EFJ4002-2PB4 EFJ400P-4PB4 EFJ4002-4PB4 EFJ400P-6P8 EFJ4002-6P8 EFJ400P-3TB4 EFJ4002-3TB4 EFJ400P-3B6 EFJ4002-3B6 EFJ400P-3MB4 EFJ4002-3MB4 EFJ600P-2PB4 EFJ6002-2PB4 EFJ600P-4PB4 EFJ6002-4PB4 EFJ600P-6P8 EFJ6002-6P8 EFJ600P-3TB4 EFJ6002-3TB4 EFJ600P-3B6 EFJ6002-3B6 EFJ600P-3MB4 EFJ6002-3MB4 EFL800P-2PB4 EFL8002-2PB4 EFL800P-4PB4 EFL8002-4PB4 EFL800P-6P8 EFL8002-6P8 EFL800P-3TB4 EFL8002-3TB4 EFL800P-3B6 EFL8002-3B6 EFL800P-3MB4 EFL8002-3MB4 7&9 (2) Transfer (3) (2) (2) Bypass (3) (2) (2) (2) Mechanical Interlock (3) (2) (2) (1) IEC rated only. (2) Consult factory for pricing and availability. (3) = Three-poles 324 For product data sheets, visit www.cooperbussmann.com/products/datasheet.asp Disconnects Overview for compact series non-fusible disconnect switches CDNF16 to CDNF160 CDNF16 CDNF160 CDNF30 Agency Information: UL listed, CSA certified, IEC rated, CE marked Catalog Number 3-pole CDNF16 CDNF25 CDNF32 CDNF45 CDNF63 CDNF30 CDNF60 CDNF100 CDNF160 General Purpose Amp Rating A 16 25 40 60 80 30 60 100 125 N/A UL508 UL508 N/A UL508 UL508 N/A UL508 UL508 N/A UL508 UL508 N/A UL508 UL508 N/A UL98 UL98 N/A UL98 UL98 N/A UL98 UL98 UL98 UL98 UL98 V 600 600 600 600 600 600 600 600 600 hp hp hp hp 3 5 10 10 7.5 7.5 15 20 10 10 20 25 15 15 30 30 20 20 40 40 10 10 20 30 20 20 40 40 25 30 50 50 30 30 75 100 3/4 2 1 3 2 5 2 5 2 5 Approvals(1) 2-pole 3-pole 4-pole Technical Ratings UL,CSA Max operating voltage Max horsepower rating Three phase 200 – 208V 240V 480V 600V Single phase 120V 240V kA kA kA kA kA kA kA A 1/2 1.5 10 10 10 10 5 — — 30 — 10 10 — 5 — — 60 10 10 10 10 5 — — 30 — 10 10 — 5 — — 60 10 10 10 10 5 — — 30 — 10 10 — 5 — — 60 — 100 100 — — — — 100 — — — — 5 — 5 150 — 100 100 — 10 — — 100 — — — — 5 — 5 150 — 50 50 — — — — 60 3 7.5 — — — — — — — — — 50 50 — — — — 60 — 25 25 — — — — 100 5 15 — 50 50 — — — — 60 7.5 20 — 25 25 — — — — 100 — 100 — — — — — 200 Technical Ratings IEC Rated insulation and operational voltage ac20 and dc20 Rated thermal current, Ith ac 20/dc 20 open ac 20/dc 20 enclosed ac 21A 500V 690V Rated operational power ac23 400/415V kW 690V kW V 750 750 750 750 750 750 750 750 750 A A A A 25 25 16 16 32 32 25 25 40 40 32 32 63 63 63 63 80 80 80 80 40 40 40 40 63 63 63 63 115 115 100 100 200 160 160 160 7.5 7.5 9 9 11 11 22 15 37 18.5 15 15 18.5 15 37 37 75 75 0.24 2.68 1.38 2.20 0.24 2.68 1.38 2.20 Physical Characteristics Weight Dimension 3-pole 3-pole lb H in W in D in 0.24 2.68 1.38 2.20 0.59 3.60 2.07 2.85 0.59 3.60 2.07 2.85 0.79 3.94 2.76 2.95 0.79 3.94 2.76 2.95 0.79 3.94 2.76 2.95 2.42 5.00 4.96 2.93 (1) UL listed switches are also CSA certified. For product data sheets, visit www.cooperbussmann.com/products/datasheet.asp 325 Disconnects Short-circuit rating with fuse Fuse type CC Fuse type J Fuse type T Fuse type RK1 Fuse type RK5 Fuse type L Fuse type H Fuse size hp hp Disconnects Overview for compact series non-fusible disconnect switches BDNF175A to BDNF3150 BDNF400A BDNF175A BDNF800A BDNF1600 Agency Information: UL listed, CSA certified, IEC rated, CE marked Catalog Number 3-pole BDNF175A BDNF200A BDNF400 BDNF600A BDNF800A BDNF1200 BDNF1600 BDNF2000 BDNF3150 200 600 General Purpose Amp Rating A 175 400 800 1200 1600 2000 3150 Approvals(1) 2-pole 3-pole 4-pole UL508 & IEC UL98 & IEC UL98 & IEC UL98 & IEC UL98 & IEC UL98 & IEC UL98 & IEC UL98 & IEC IEC UL508 & IEC UL98 & IEC UL98 & IEC UL98 & IEC UL98 & IEC UL98 & IEC UL98 & IEC UL98 & IEC IEC IEC IEC UL98 & IEC UL98 & IEC IEC IEC IEC IEC IEC Technical Ratings UL, CSA Max operating voltage Max horsepower rating Three phase 200 – 208V 240V 480V 600V Single phase 120V 240V Short-circuit rating with fuse Fuse type CC Fuse type J Fuse type T Fuse type RK1 Fuse type RK5 Fuse type L Fuse type H Fuse size V 600 600 600 600 600 600 600 600 600 hp hp hp hp 30 40 75 100 60 75 150 200 100 125 250 350 150 200 400 500 200 250 500 600 — — — — — — — — — — — — — — — — hp hp — — — — — — — — — — — — — — — — — — kA kA kA kA kA kA kA A — 100 — — 100 — — 200 — — — — 100 — — 200 — — — — 100 — — 600 — — — — 100 — — 600 — — — — — — — 1200 — — — — — 100 — 1200 — — — — — 100 — 2000 — — — — — 100 — 2000 — — — — — — — — 1000 1000 1000 1000 1000 1000 1000 1000 1000 A A A A 200 200 200 200 315 270 250 250 630 630 630 630 800 720 800 800 1250 1250 1250 1250 1600 1600 1600 1600 2500 2300 2500 2500 2500 2300 2500 2500 3150 2600 3150 3150 kW kW 90 170 132 200 315 355 355 355 400 — 400 — 400 — 400 — 400 — 127.7 25.04 18.43 10.67 127.7 25.04 18.43 10.67 127.7 25.04 18.43 10.67 Technical Ratings IEC Rated insulation and operational voltage. ac20 and dc20 V Rated thermal current, Ith ac 20/dc 20open ac 20/dc 20 enclosed ac 21A 500V 690V Rated operational power ac23 400/415V 690V Physical Characteristics Weight Dimension 3-pole 3-pole lb H in W in D in 6.61 8.35 7.83 4.55 6.61 8.35 8.62 4.55 13.66 11.81 10.24 5.12 13.66 11.77 11.93 5.12 35.9 19.09 14.29 4.92 38.55 19.09 14.29 4.92 (1) UL listed switches are also CSA certified. 326 For product data sheets, visit www.cooperbussmann.com/products/datasheet.asp Disconnects 16-100A Base & DIN rail mount compact series non-fusible disconnect switches Handle - Selector 16-100A 3-Pole For a complete assembly, please select one of each: • 1 switch • 1 shaft • 1 handle 16—100A/600V 3 Pole(1) Switches Catalog Numbers CDNF16 CDNF25 CDNF32 CDNF45 CDNF63 CDNF30 CDNF60 CDNF100 UL General Maximum Horsepower Rating Purpose IEC AC21 Single Phase Three Phase Amp Rating Amp Rating 120V 240V 240V 480V 600V 1 16 16 ⁄2 1.5 5 10 10 3 25 25 ⁄4 2 7.5 15 20 40 40 1 3 10 20 25 60 63 2 5 15 30 30 80 80 2 5 20 40 40 30 40 2 5 10 20 30 60 63 3 7.5 20 40 40 100 115 5 15 30 50 50 Terminal Lugs Wire Size/Type #18-8/CU #18-8/CU #18-8/CU #14-4/CU #14-4/CU #14-4/CU #14-4/CU #8-1/0/CU (1) A snap-on fourth pole may be added. CDNF16 CDNF25 CDNF32 Shafts — For use with CDH selector handles 0.20 x 0.20" ( 5 x 5 mm) Mounting Depth(2) in inches Catalog Numbers CDS85S CDS105S CDS120S CDS130S CDS180S CDS250S CDS330S Shaft Length in (mm) 3.3 (85) 4.1 (105) 4.7 (120) 5.1 (130) 7.1 (180) 9.8 (250) 13 (330) CDNF16 CDNF25 CDNF32 CDH1S CDH2S CDH15S CDH16S 4.2-5.0 5.0-5.8 5.6-6.4 6.0-6.7 7.1-8.7 10.7-11.5 13.8-14.6 CDH3S CDH4S CDH5S CDH6S 3.6-4.3 4.4-5.1 5.0-5.8 5.4-6.1 7.4-8.1 10.1-10.8 13.3-14.0 CDNF45 CDNF63 CDH1S CDH2S CDH15S CDH16S 4.9-5.6 5.7-6.4 6.3-7.0 6.7-7.4 8.6-9.4 11.4-12.1 14.6-15.3 CDH3S CDH4S CDH5S CDH6S 4.4-5.0 5.1-5.8 5.7-6.4 6.1-6.8 8.1-8.7 10.9-11.5 14.0-14.7 CDNF30 CDNF60 CDNF100 CDH3S CDH4S CDH5S CDH6S 3.9-4.9 4.7-5.7 5.3-6.3 5.6-6.7 7.6-8.6 10.4-11.4 13.5-14.5 (2) Mounting depth is the distance from the outside of door to the disconnect switch mounting plate. Shaft can be cut to desired length. Handle - Selector — For use with shafts 0.20 x 0.20" ( 5 x 5 mm) IEC Type IP54 IP54 IP54 IP54 IP65 IP65 IP65 IP65 Color Black Red/Yellow Black Red/Yellow Black Red/Yellow Black Red/Yellow Defeatable — — — — — — Yes Yes CDS_ S Disconnects All marked both O/I & Off/On Catalog Numbers NEMA Type CDH1S(3) 1 CDH2S(3) 1 CDH15S(3) 1 CDH16S(3) 1 CDH3S 1,3R,12 CDH4S 1,3R,12 CDH5S 1,3R,12 CDH6S 1,3R,12 Padlockable — — Yes Yes Yes Yes Yes Yes (3) Not suitable for use with CDNF30, 60, 100. Knob - Replacement Mounts directly to Catalog Numbers OPMRH CDBY68306(3) CDBY68419/1(3) CDMC1 CDSWM5X8 switch; no shaft necessary NEMA Type Color For Use On: 1 Red CDNF16, 25, 32 1 Red CDNF30, 45, 60, 63,100 1 Red CDNF30, 45, 60, 63,100 Metal collar — CDNF16 – CDNF100 Set screw — CDNF16, 25, 30, 32, 45, 60, 63, 100 (4) 0.1875" (3/16") diameter shackle required. (5) Set screw CDSWM5X8 needed with replacement knobs CDBY__. Length (inches) Padlockable 1.0 — 1.4 — 1.6 Yes(5) — — — — CDH15S For product data sheets, visit www.cooperbussmann.com/products/datasheet.asp 327 Disconnects 16-100A Base & DIN rail mount compact series non-fusible disconnect switches Handle - Pistol 16-100A 3-Pole For a complete assembly, please select one of each: • 1 switch • 1 shaft • 1 handle 16—100A/600V 3-Pole(1) Switches Catalog Numbers CDNF16 CDNF25 CDNF32 CDNF45 CDNF63 CDNF30 CDNF60 CDNF100 UL General Maximum Horsepower Rating Purpose IEC AC21 Single Phase Three Phase Amp Rating Amp Rating 120V 240V 240V 480V 600V 1 16 16 ⁄2 1.5 5 10 10 3 25 25 ⁄4 2 7.5 15 20 40 40 1 3 10 20 25 60 63 2 5 15 30 30 80 80 2 5 20 40 40 30 40 2 5 10 20 30 60 63 3 7.5 20 40 40 100 115 5 15 30 50 50 Terminal Lugs Wire Size/Type #18-8/CU #18-8/CU #18-8/CU #14-4/CU #14-4/CU #14-4/CU #14-4/CU #8-1/0/CU (1) A snap-on fourth pole may be added. CDNF30 CDNF60 CDNF100 Shafts — For use with pistol handles 0.20 x 0.20" ( 5 x 5 mm) Catalog Numbers CDS48P CDS67P CDS49P CDS50P CDS99P Shaft Length in (mm) 5.9 (150) 6.7 (170) 10.4 (265) 15.8 (400) 19.7 (500) Mounting Depth(1) in inches CDNF16 CDNF25 CDNF45 CDNF32 CDNF63 6.2-6.7 6.9-7.4 7.0-7.5 7.7-8.1 10.7-11.3 11.4-11.9 16.0-16.6 16.8-17.2 20.0-20.5 20.7-21.1 CDNF30 CDNF60 CDNF100 6.4-7.4 7.2-8.1 10.9-11.9 16.2-17.2 20.1-21.1 (1) Mounting depth is the distance from the outside of door to the disconnect switch mounting plate. Shaft can be cut to desired length. Shafts - Twisted — Rotates handle 45° 0.20 x 0.20" ( 5 x 5 mm) Catalog Numbers CDS48T CDS67T CDS49T CDS50T Shaft Length in (mm) 5.9 (150) 6.7 (170) 10.4 (265) 15.8 (400) CDS_P Mounting Depth(1) in inches CDNF16 CDNF30 CDNF25 CDNF45 CDNF60 CDNF32 CDNF63 CDNF100 6.2-6.7 6.9-7.4 6.4-7.4 7.0-7.5 7.7-8.1 7.2-8.1 10.7-11.3 11.4-11.9 10.9-11.9 16.0-16.6 16.8-17.2 16.2-17.2 (1) Mounting depth is the distance from the outside of door to the disconnect switch mounting plate. Shaft can be cut to desired length. Handle - Pistol — For use with shafts 0.20 x 0.20" ( 5 x 5 mm) Catalog Number BDH104 BDH105 BDH106 BDH107 CDHXB65 CDHXY65 NEMA Type 1,3R,12 1,3R,12 1,3R,12 1,3R,12 1,3R,12,4,4X 1,3R,12,4,4X IEC Type IP65 IP65 IP65 IP65 IP66 IP66 Color Black Red/Yel Black Red/Yel Black Red/Yel Marking O/I & Off/On O/I & Off/On O/I & Off/On O/I & Off/On O/I & Off/On O/I & Off/On Length in (mm) 1.8 (45) 1.8 (45) 2.6 (65) 2.6 (65) 2.6 (65) 2.6 (65) Defeatable Yes Yes Yes Yes Yes Yes Padlockable Yes Yes Yes Yes Yes Yes BDH107 328 For product data sheets, visit www.cooperbussmann.com/products/datasheet.asp Disconnects 16-100A door mounted compact series non-fusible disconnect switches Handle - Selector 16-100A 3-Pole For a complete assembly, please select one of each: • 1 switch • 1 handle Note: Door mounted switches do not provide door interlock. 16—100A/600V 3 Pole(1)(2)(3) Switches Catalog Number CDNF16D CDNF25D CDNF32D CDNF45D CDNF63D CDNF30D CDNF60D CDNF100D (1) (2) (3) (4) UL General Maximum Horsepower Rating Purpose IEC AC21 Single Phase Three Phase Amp Rating Amp Rating 120V 240V 240V 480V 600V 1 16 16 ⁄2 1.5 5 10 10 3 25 25 ⁄4 2 7.5 15 20 40 40 1 3 10 20 25 60(4) 63 2 5 15 30 30 80(4) 80 2 5 20 40 40 30(4) 40 2 5 10 20 30 60(4) 63 3 7.5 20 40 40 100(4) 115 5 15 30 50 50 Terminal Lugs Wire Size/Type #18-8/CU #18-8/CU #18-8/CU #14-4/CU #14-4/CU #14-4/CU #14-4/CU #8-1/0/CU A snap-on fourth pole may be added. Door mounted switches do not require shafts. CDNF16, 25, 32, 45 & 63 door mounted switches will not accept pistol handles. CDNF45 & 63 door mounted switches can only use screw mounted handles. CDNF16D CDNF25D CDNF32D Handles - Selector All marked both O/I & Off/On Catalog NEMA Numbers Type IEC Type Color Defeatable Padlockable Snap-on mounting — for use on CDNF16, 25, 32D CDH7S CDH8S CDH19S CDH20S CDH9S CDH10S 1 1 1 1 1,3R,12 1,3R,12 IP54 IP54 IP54 IP54 IP65 IP65 Black Red/Yellow Black Red/Yellow Black Red/Yellow — — — — — — — — Yes Yes Yes Yes Screw mounting — for use on CDNF16, 32, 45 & 63D 1 1 1 1 1,3R,12 1,3R,12 IP54 IP54 IP54 IP54 IP65 IP65 Black Red/Yellow Black Red/Yellow Black Red/Yellow — — — — — — — — Yes Yes Yes Yes Disconnects CDH11S CDH12S CDH17S CDH18S CDH13S CDH14S CDH9S CDH13S Handle Adapter - Pistol Grip Catalog Number CDHZX6 Description Adapter piece for pistol grip handle For Use On: CDNF30D, CDNF60D, CDNF100D NOTE: The model pistol grip handles used on the non-door mounted switches shown on the bottom of page 321, are the available handles. For product data sheets, visit www.cooperbussmann.com/products/datasheet.asp 329 Disconnects 400-800A non-fusible compact series disconnect switches Handle - Pistol 400-800A 2-, 3- and 4-Pole • • • • For a complete assembly, please select one of each: 1 switch 1 handle 1 shaft 1 terminal lug kit Switches 400-800A/600V Catalog Number BDNF4002 BDNF600A2 BDNF800A2 BDNF400 BDNF600A BDNF800A BDNF4004 BDNF600A4 BDNF800A4 Poles 2 2 2 3 3 3 4 4 4 UL General Purpose Amp Rating 400 600 800 400 600 800 400 600 — IEC AC21 Amp Rating 630 800 1250 630 800 1250 630 800 1250 Maximum Horsepower Rating 200V 208V 240V 480V — — — — — — — — — — — — 100 100 125 250 150 150 200 400 200 200 250 500 100 100 125 250 150 150 200 400 200 200 250 500 600V — — — 350 500 600 350 500 600 BDNF600A Shafts — for use with pistol handles 0.47 x 0.47" ( 12 x 12 mm) Catalog Numbers BDS280 BDS325 BDS395 BDS465 BDS535 Shaft Length in (mm) 11.0 (280) 12.8 (325) 15.6 (395) 18.3 (465) 21.1 (535) Mounting Depth(1) in Inches 10.2-14.5 12.0-16.3 14.8-19.1 17.5-21.9 20.3-24.6 (1) Mounting depth is the distance from the outside of the door to the disconnect switch mounting plate. Shaft can be cut to desired length. Shafts - Twisted — Rotates handle 45° 0.47 x 0.47" ( 12 x 12 mm) Catalog Numbers BDS28045 BDS32545 BDS46545 Shaft Length in (mm) 11.0 (280) 12.8 (325) 18.3 (465) BDS280 Mounting Depth(1) in Inches 10.2-14.5 12.0-16.3 17.5-21.9 (1) Mounting depth is the distance from the outside of the door to the disconnect switch mounting plate. Shaft can be cut to desired length. Handles - Pistol — for use with shafts 0.47 x 0.47” ( 12 x 12 mm) Catalog Number BDH112 BDH113 BDH114 BDH115 BDH116 BDH117 CDHXB12 CDHXY12 CDHXB22 BDH8 NEMA type IEC type 1,3R,12 IP65 1,3R,12 IP65 1,3R,12 IP65 1,3R,12 IP65 1,3R,12 IP65 1,3R,12 IP65 1,3R,4,4X,12 IP66 1,3R,4,4X,12 IP66 1,3R,4,4X,12 IP66 1,3R,4,4X,12 IP65 Color Blk R/Y Blk R/Y Blk R/Y Blk R/Y Blk Metal Length in (mm) 4.9 (125) 4.9 (125) 5.7 (145) 5.7 (145) 6.9 (175) 6.9 (175) 5.7 (145) 5.7 (145) 6.9 (175) 8.7 (220) Marking O/I & Off/On O/I & Off/On O/I & Off/On O/I & Off/On O/I & Off/On O/I & Off/On O/I & Off/On O/I & Off/On O/I & Off/On Off/On Defeatable Yes Yes Yes Yes Yes Yes Yes Yes Yes — Padlockable Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Lug Kits - Terminal Catalog Numbers BDTL26 BDTL262 BDTL27 BDTL30 BDTL32 BDTL175/400 For Use On: BDNF400 BDNF400 BDNF600A BDNF800A BDNF800A1 BDNF400-BDNF600A(1) Wire Size/Type #2-600 kcmil/CU/AL (2) #2-500 kcmil/CU/AL (2) #2-600 kcmil/CU/AL (2) #2-600 kcmil/CU/AL (8) 2/0 + (2)#2 600 kcmil/CU/AL (12) #14-6/CU/AL Lugs Per Kit 6 6 6 6 3 3 (1) A load side distribution lug eliminates the need to purchase, install and wire a separate distribution block. BDTL175/400 330 For product data sheets, visit www.cooperbussmann.com/products/datasheet.asp Disconnects Accessories for 400-800A compact series non-fusible disconnect switches Auxiliary Contacts (2) Catalog Numbers BDAUX1 BDAUX2 BDAUX3 BDAUX4 BDAUX5 BDAUX6 Description 1 NO + 1 NC 2 NO + 2 NC 4 NO + 4 NC 2 NO 4 NO 8 NO For Use On: BDNF400 – BDNF800A BDNF800A BDNF800A BDNF800A BDNF800A AC Thermal AC Rated Amp Rating 10 10 10 10 10 10 Voltage 600 600 600 600 600 600 BDAUX1-6 (2) UL File E57057 Terminal Poles Catalog Number Description BDZX85 Detachable neutral mounts on side of switch or DIN rail AC Thermal For Use On: Amp Rating BDNF400 – 400 BDNF600A 400 AC Rated Voltage 600 600 BDZX85 Terminal Shrouds Catalog Numbers BDTS4 BDTS6A BDTS8A Description Includes one shroud for line or load side For Use On: BDNF400 BDNF600A BDNF800A BDTS Disconnects Handle Support Bracket Catalog Numbers BDZX73 BDZX71 Description Allows handle to be directly mounted to switch behind the door For Use On: BDNF400 – BDNF600A BDNF800A BDZX71 For product data sheets, visit www.cooperbussmann.com/products/datasheet.asp 331 Disconnects 16–80A, 600V 3-Pole enclosed compact series non-fusible disconnect switches Selector Handle NEMA 1, 3R, 4 & 4X Catalog Numbers UL General Purpose Amp Rating 16 25 40 60 80 1 ENF161-3PBJ ENF251-3PBJ ENF321-3PBJ ENF451-3PBJ ENF631-3PBJ Catalog Numbers NEMA Enclosure Type (1) 3R 4 ENF163-3PBJ ENF164-3PBJ ENF253-3PBJ ENF254-3PBJ ENF323-3PBJ ENF324-3PBJ ENF453-3PBJ ENF454-3PBJ ENF633-3PBJ ENF634-3PBJ 4X Stainless ENF16X-3PBJ ENF25X-3PBJ ENF32X-3PBJ ENF45X-3PBJ ENF63X-3PBJ ENF321-3PBJ (1) Enclosures are rated as listed, selector handles are only NEMA rated 1, 3R, 12. The overall NEMA rating of an enclosed switch with a selector handle is 1, 3R, 12. Selector Handle NEMA 4X and 12, IEC IP65 Catalog Numbers UL General Purpose Amp Rating 16 25 40 60 80 Catalog Numbers NEMA Enclosure Type 4X Plastic(1) 12(1) ENF16P-3PBJ ENF162-3PBJ ENF25P-3PBJ ENF252-3PBJ ENF32P-3PBJ ENF322-3PBJ ENF45P-3PBJ ENF452-3PBJ ENF63P-3PBJ ENF632-3PBJ IEC Enclosure Type IP65 Plastic ENF16E-3PBJ ENF25E-3PBJ ENF32E-3PBJ ENF45E-3PBJ ENF63E-3PBJ (1) Enclosures are rated as listed, selector handles are only NEMA rated 1, 3R, 12. The overall NEMA rating of an enclosed switch with a selector handle is 1, 3R, 12. ENF252-3PYJ ENF16E-3PBJ ENF45E-3PBJ Selector Handle Ratings, 600V Amp Rating 16-100 16-100 NEMA Rating 1, 3R, 12 1, 3R, 12 Color Black Red/Yel Marking O/I & OFF/ON O/I & OFF/ON Detachable Yes Yes Padlockable Yes Yes Cat. No. Suffix BJ YJ Catalog Number CDH5S CDH6S NOTE: All enclosed switches come with a black handle. However, most handles can be substituted with a red/yellow handle. Please substitute the handle suffix code (1st and 2nd from last characters) with the red/yellow handle catalog number suffix listed in the table to the left. There is no additional cost for a red/yellow handle of equal rating and style. EXAMPLE: A red/yellow selector handle for an ENF161-3PBJ can be substituted for the black selector handle by using the "YJ" suffix instead of the "BJ" suffix, new catalog #ENF161-3PYJ. 332 For product data sheets, visit www.cooperbussmann.com/products/datasheet.asp Disconnects 16A-3150A, 600V 3-Pole enclosed compact series non-fusible disconnect switches Pistol Handle NEMA 1, 3R, 4 & 4X Catalog Numbers UL General Purpose Amp Rating 16 25 40 60 80 30 60 100 125 200 400 600 800 1200 1600 2000 3150(2) Agency Listing UL 508 UL 508 UL 508 UL 508 UL 508 UL98 UL98 UL98 UL98 UL98 UL98 UL98 UL98 UL98 UL98 UL98 UL98 1 ENF161-3PB6 ENF251-3PB6 ENF321-3PB6 ENF451-3PB6 ENF631-3PB6 ENF301-3PB6 ENF601-3PB6 ENF1001-3PB6 ENF1251-3PB6 ENF2001-3PB8 ENF4001-3PB4 ENF6001-3PB4 ENF8001-3PB4 ENF12001-3PB4 ENF16001-3P8 ENF20001-3P8 ENF31501-3P8 Catalog Numbers NEMA Enclosure Type 3R 4 ENF163-3PB6 ENF164-3PB6 ENF253-3PB6 ENF254-3PB6 ENF323-3PB6 ENF324-3PB6 ENF453-3PB6 ENF454-3PB6 ENF633-3PB6 ENF634-3PB6 ENF303-3PB6 ENF304-3PB6 ENF603-3PB6 ENF604-3PB6 ENF1003-3PB6 ENF1004-3PB6 ENF1253-3PB6 ENF1254-3PB6 ENF2003-3PB8 ENF2004-3PB8 ENF4003-3PB4 ENF4004-3PB4 ENF6003-3PB4 ENF6004-3PB4 ENF8003-3PB4 ENF8004-3PB4 ENF12003-3PB4 ENF12004-3PB4 ENF16003-3P8 ENF16004-3P8 ENF20003-3P8 ENF20004-3P8 ENF31503-3P8 ENF31504-3P8 4X Stainless ENF16X-3PB6 ENF25X-3PB6 ENF32X-3PB6 ENF45X-3PB6 ENF63X-3PB6 ENF30X-3PB6 ENF60X-3PB6 ENF100X-3PB6 ENF125X-3PB6 ENF200X-3PB8 ENF400X-3PB4 ENF600X-3PB4 ENF800X-3PB4 ENF1200X-3PB4 ENF1600X-3P8 ENF2000X-3P8 ENF3150X-3P8 ENF63X-3PB6 (2) IEC rated only. Pistol Handle NEMA 4X, 12 and 7 & 9, IEC IP65 Catalog Numbers Agency Listing UL 508 UL 508 UL 508 UL 508 UL 508 UL 98 UL 98 UL 98 UL 98 UL 98 UL 98 UL 98 UL 98 UL 98 UL 98 UL 98 UL 98 4X Plastic ENF16P-3PB6 ENF25P-3PB6 ENF32P-3PB6 ENF45P-3PB6 ENF63P-3PB6 ENF30P-3PB6 ENF60P-3PB6 ENF100P-3PB6 ENF125P-3PB6 ENF200P-3PB8 ENF400P-3PB4 ENF600P-3PB4 ENF800P-3PB4 ENF1200P-3PB4 ENF1600P-3P8 ENF2000P-3P8 ENF3150P-3P8 Catalog Numbers NEMA Enclosure Type 12 7&9 ENF162-3PB6 ENF167-3P ENF252-3PB6 ENF257-3P ENF322-3PB6 ENF327-3P ENF452-3PB6 ENF457-3P ENF632-3PB6 ENF637-3P ENF302-3PB6 ENF307-3P ENF602-3PB6 ENF607-3P ENF1002-3PB6 ENF1007-3P ENF1252-3PB6 — ENF2002-3PB8 — ENF4002-3PB4 — ENF6002-3PB4 — ENF8002-3PB4 — ENF12002-3PB4 — ENF16002-3P8 — ENF20002-3P8 — ENF31502-3P8 — IEC Enclosure Type IP65 Plastic ENF16E-3PB4 ENF25E-3PB4 ENF32E-3PB4 ENF45E-3PB4 ENF63E-3PB4 ENF30E-3PB6 ENF60E-3PB6 ENF100E-3PB6 ENF125E-3PB6 — — — — — — — — ENF25P-3PY6 (2) IEC rated only. Pistol Handle Ratings: 16-3150A, 600V Amp Rating 16-100 125 200 400-3150 NEMA Rating 1, 3R, 12 1, 3R, 12 1, 3R, 4, 4X, 1, 3R, 4, 4X, 1, 3R, 12 1, 3R, 12 1, 3R, 4, 4X, 1, 3R, 4, 4X, 1, 3R, 12 1, 3R, 12 1, 3R, 4, 4X, 1, 3R, 4, 4X, 1, 3R, 12 1, 3R, 12 1, 3R, 12 1, 3R, 12 1, 3R, 4, 4X, 1, 3R, 4, 4X, 1, 3R, 4, 4X, 1, 3R, 4, 4X, 1, 3R, 4, 4X, 12 12 12 12 12 12 12 12 12 12 12 Color Black Red/Yel Black Red/Yel Black Red/Yel Black Red/Yel Black Red/Yel Black Red/Yel Black Red/Yel Black Red/Yel Black Red/Yel Black Red/Yel Metal Marking O/I & OFF/ON O/I & OFF/ON O/I & OFF/ON O/I & OFF/ON O/I & OFF/ON O/I & OFF/ON O/I & OFF/ON O/I & OFF/ON O/I & OFF/ON O/I & OFF/ON O/I & OFF/ON O/I & OFF/ON O/I & OFF/ON O/I & OFF/ON O/I & OFF/ON O/I & OFF/ON O/I & OFF/ON O/I & OFF/ON O/I & OFF/ON O/I & OFF/ON O/I & OFF/ON Detachable Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes No Cat. No. Padlockable Suffix Yes B6 Yes Y6 Yes B6 Yes Y6 Yes B6 Yes Y6 Yes B8 Yes Y8 Yes B8 Yes Y8 Yes B8 Yes Y8 Yes B4 Yes Y4 Yes B7 Yes Y7 Yes B4 Yes Y4 Yes B7 Yes Y7 Yes 8 Catalog Number BDH106 BDH107 CDHXB65 CDHXY65 BDH120 BDH121 CDHXB86 CDHXY86 BDH110 BDH111 CDHXB88 CDHXY88 BDH114 BDH115 BDH116 BDH117 CDHXB12 CDHXY12 CDHXB22 CDHXY22 BDH8 NOTE: All enclosed switches come with a black handle. However, most handles can be substituted with a red/yellow handle. Please substitute the handle suffix code (1st and 2nd from last characters) with the red/yellow handle catalog number suffix listed in the table to the left. There is no additional cost for a red/yellow handle of equal rating and style. EXAMPLE: A red/yellow pistol handle for an ENF1613PBJ can be substituted for the black selector handle by using the "YJ" suffix instead of the "BJ" suffix, new catalog #ENF161-3PYJ. For product data sheets, visit www.cooperbussmann.com/products/datasheet.asp 333 Disconnects UL General Purpose Amp Rating 16 25 40 60 80 30 60 100 125 200 400 600 800 1200 1600 2000 3150(2) Disconnects 16-400A 2-, 4- and 6-Pole enclosed compact series non-fusible disconnect switches NEMA 4X, 12 and 7&9 for Transfer, Bypass and Mechanical Interlock Applications Catalog Numbers UL General Purpose Amp Rating 16 25 40 60 80 30 60 100 125 200 400 (3) 334 Switch Type 4-Pole 6-Pole Transfer Bypass Mech. interlock 4-Pole 6-Pole Transfer Bypass Mech. interlock 4-Pole 6-Pole Transfer Bypass Mech. interlock 4-Pole 6-Pole Transfer Bypass Mech. interlock 4-Pole 6-Pole Transfer Bypass Mech. interlock 4-Pole 6-Pole Transfer Bypass Mech. interlock 4-Pole 6-Pole Transfer Bypass Mech. interlock 4-Pole 6-Pole Transfer Bypass Mech. interlock 2-Pole 4-Pole 6-Pole Transfer Bypass Mech. interlock 2-Pole 4-Pole 6-Pole Transfer Bypass Mech. interlock 2-Pole 4-Pole 6-Pole Transfer Bypass Mech. interlock 1 ENF161-4PB6 ENF161-6PB6 ENF161-3TB8 ENF161-3BB8 ENF161-3MB6 ENF251-4PB6 ENF251-6PB6 ENF251-3TB8 ENF251-3BB8 ENF251-3MB6 ENF321-4PB6 ENF321-6PB6 ENF321-3TB8 ENF321-3BB8 ENF321-3MB6 ENF451-4PB6 ENF451-6PB6 ENF451-3TB8 ENF451-3BB8 ENF451-3MB6 ENF631-4PB6 ENF631-6PB6 ENF631-3TB8 ENF631-3BB8 ENF631-3MB6 ENF301-4PB6 ENF301-6PB6 ENF301-3TB8 ENF301-3BB8 ENF301-3MB6 ENF601-4PB6 ENF601-6PB6 ENF601-3TB8 ENF601-3BB8 ENF601-3MB6 ENF1001-4PB6 ENF1001-6PB6 ENF1001-3TB8 ENF1001-3BB8 ENF1001-3MB6 ENF1251-2PB6 ENF1251-4PB6 ENF1251-6PB2 ENF1251-3TB8 — ENF1251-3MB6 ENF2001-2PB8 ENF2001-4PB8 ENF2001-6PB4 ENF2001-3TB4 ENF2001-3BB4 ENF2001-3MB8 ENF4001-2PB4 ENF4001-4PB4 ENF4001-6P8 ENF4001-3TB4 ENF4001-3B6 ENF4001-3MB4 Catalog Numbers NEMA Enclosure Type 3R 4 ENF163-4PB6 ENF164-4PB6 ENF163-6PB6 ENF164-6PB6 ENF163-3TB8 ENF164-3TB8 ENF163-3BB8 ENF164-3BB8 ENF163-3MB6 ENF164-3MB6 ENF253-4PB6 ENF254-4PB6 ENF253-6PB6 ENF254-6PB6 ENF253-3TB8 ENF254-3TB8 ENF253-3BB8 ENF254-3BB8 ENF253-3MB6 ENF254-3MB6 ENF323-4PB6 ENF324-4PB6 ENF323-6PB6 ENF324-6PB6 ENF323-3TB8 ENF324-3TB8 ENF323-3BB8 ENF324-3BB8 ENF323-3MB6 ENF324-3MB6 ENF453-4PB6 ENF454-4PB6 ENF453-6PB6 ENF454-6PB6 ENF453-3TB8 ENF454-3TB8 ENF453-3BB8 ENF454-3BB8 ENF453-3MB6 ENF454-3MB6 ENF633-4PB6 ENF634-4PB6 ENF633-6PB6 ENF634-6PB6 ENF633-3TB8 ENF634-3TB8 ENF633-3BB8 ENF634-3BB8 ENF633-3MB6 ENF634-3MB6 ENF303-4PB6 ENF304-4PB6 ENF303-6PB6 ENF304-6PB6 ENF303-3TB8 ENF304-3TB8 ENF303-3BB8 ENF304-3BB8 ENF303-3MB6 ENF304-3MB6 ENF603-4PB6 ENF604-4PB6 ENF603-6PB6 ENF604-6PB6 ENF603-3TB8 ENF604-3TB8 ENF603-3BB8 ENF604-3BB8 ENF603-3MB6 ENF604-3MB6 ENF1003-4PB6 ENF1004-4PB6 ENF1003-6PB6 ENF1004-6PB6 ENF1003-3TB8 ENF1004-3TB8 ENF1003-3BB8 ENF1004-3BB8 ENF1003-3MB6 ENF1004-3MB6 ENF1253-2PB6 ENF1254-2PB6 ENF1253-4PB6 ENF1254-4PB6 ENF1253-6PB2 ENF1254-6PB4 ENF1253-3TB8 ENF1254-3TB8 — — ENF1253-3MB6 ENF1254-3MB8 ENF2003-2PB8 ENF2004-2PB8 ENF2003-4PB8 ENF2004-4PB8 ENF2003-6PB4 ENF2004-6PB4 ENF2003-3TB4 ENF2004-3TB4 ENF2003-3BB4 ENF2004-3BB4 ENF2003-3MB8 ENF2004-3MB8 ENF4003-2PB4 ENF4004-2PB4 ENF4003-4PB4 ENF4004-4PB4 ENF4003-6P8 ENF4004-6P8 ENF4003-3TB4 ENF4004-3TB4 ENF4003-3B6 ENF4004-3B6 ENF4003-3MB4 ENF4004-3MB4 4X Stainless ENF16X-4PB6 ENF16X-6PB6 ENF16X-3TB8 ENF16X-3BB8 ENF16X-3MB6 ENF25X-4PB6 ENF25X-6PB6 ENF25X-3TB8 ENF25X-3BB8 ENF25X-3MB6 ENF32X-4PB6 ENF32X-6PB6 ENF32X-3TB8 ENF32X-3BB8 ENF32X-3MB6 ENF45X-4PB6 ENF45X-6PB6 ENF45X-3TB8 ENF45X-3BB8 ENF45X-3MB6 ENF63X-4PB6 ENF63X-6PB6 ENF63X-3TB8 ENF63X-3BB8 ENF63X-3MB6 ENF30X-4PB6 ENF30X-6PB6 ENF30X-3TB8 ENF30X-3BB8 ENF30X-3MB6 ENF60X-4PB6 ENF60X-6PB6 ENF60X-3TB8 ENF60X-3BB8 ENF60X-3MB6 ENF100X-4PB6 ENF100X-6PB6 ENF100X-3TB8 ENF100X-3BB8 ENF100X-3MB6 ENF125X-2PB6 ENF125X-4PB6 ENF125X-6PB4 ENF125X-3TB8 — ENF125X-3MB8 ENF200X-2PB8 ENF200X-4PB8 ENF200X-6PB4 ENF200X-3TB4 ENF200X-3BB4 ENF200X-3MB8 ENF400X-2PB4 ENF400X-4PB4 ENF400X-6P8 ENF400X-3TB4 ENF400X-3B6 ENF400X-3MB4 = Three-poles For product data sheets, visit www.cooperbussmann.com/products/datasheet.asp Transfer (3) Bypass (3) Mechanical Interlock (3) Disconnects 16-400A 2-, 4- and 6-Pole enclosed compact series non-fusible disconnect switches NEMA 4X, 12 and 7&9, and IEC IP65 for Transfer, Bypass and Mechanical Interlock Applications Catalog Numbers UL General Purpose Amp Rating 16 25 40 60 80 30 60 125 200 400 4X Plastic ENF16P-4PB6 ENF16P-6PB6 ENF16P-3TB8 ENF16P-3BB8 ENF16P-3MB6 ENF25P-4PB6 ENF25P-6PB6 ENF25P-3TB8 ENF25P-3BB8 ENF25P-3MB6 ENF32P-4PB6 ENF32P-6PB6 ENF32P-3TB8 ENF32P-3BB8 ENF32P-3MB6 ENF45P-4PB6 ENF45P-6PB6 ENF45P-3TB8 ENF45P-3BB8 ENF45P-3MB6 ENF63P-4PB6 ENF63P-6PB6 ENF63P-3TB8 ENF63P-3BB8 ENF63P-3MB6 ENF30P-4PB6 ENF30P-6PB6 ENF30P-3TB8 ENF30P-3BB8 ENF30P-3MB6 ENF60P-4PB6 ENF60P-6PB6 ENF60P-3TB8 ENF60P-3BB8 ENF60P-3MB6 ENF100P-4PB6 ENF100P-6PB6 ENF100P-3TB8 ENF100P-3BB8 ENF100P-3MB6 ENF125P-2PB6 ENF125P-4PB6 ENF125P-6PB2 ENF125P-3TB8 — ENF125P-3MB6 ENF200P-2PB8 ENF200P-4PB8 ENF200P-6PB4 ENF200P-3TB4 ENF200P-3BB4 ENF200P-3MB8 ENF400P-2PB4 ENF400P-4PB4 ENF400P-6P8 ENF400P-3TB4 ENF400P-3B6 ENF400P-3MB4 Catalog Numbers NEMA Enclosure Type 12 7&9 ENF162-4PB6 ENF167-4P ENF162-6PB6 ENF167-6P ENF162-3TB8 ENF167-3T ENF162-3BB8 ENF167-3B ENF162-3MB6 — ENF252-4PB6 ENF257-4P ENF252-6PB6 ENF257-6P ENF252-3TB8 ENF257-3T ENF252-3BB8 ENF257-3B ENF252-3MB6 — ENF322-4PB6 ENF327-4P ENF322-6PB6 ENF327-6P ENF322-3TB8 ENF327-3T ENF323-3BB8 ENF327-3B ENF322-3MB6 — ENF452-4PB6 ENF457-4P ENF452-6PB6 ENF457-6P ENF452-3TB8 ENF457-3T ENF452-3BB8 ENF457-3B ENF452-3MB6 — ENF632-4PB6 ENF637-4P ENF632-6PB6 ENF637-6P ENF632-3TB8 ENF637-3T ENF632-3BB8 ENF637-3B ENF632-3MB6 — ENF302-4PB6 ENF307-4P ENF302-6PB6 ENF307-6P ENF302-3TB8 ENF307-3T ENF302-3BB8 ENF307-3B ENF302-3MB6 — ENF602-4PB6 ENF607-4P ENF602-6PB6 ENF607-6P ENF602-3TB8 ENF607-3T ENF602-3BB8 ENF607-3B ENF602-3MB6 — ENF1002-4PB6 ENF1007-4P ENF1002-6PB6 ENF1007-6P ENF1002-3TB8 ENF1007-3T ENF1002-3BB8 ENF1007-3B ENF1002-3MB6 — ENF1252-2PB6 ENF1257-2P ENF1252-4PB6 ENF1257-4P ENF1252-6PB2 ENF1257-6P ENF1252-3TB8 ENF1257-3T — — ENF1252-3MB6 — ENF2002-2PB8 ENF2007-2P ENF2002-4PB8 ENF2007-4P ENF2002-6PB4 ENF2007-6P ENF2002-3TB4 ENF2007-3T ENF2002-3BB4 ENF2007-3B ENF2002-3MB8 — ENF4002-2PB4 ENF4007-2P ENF4002-4PB4 ENF4007-4P ENF4002-6P8 ENF4007-6P ENF4002-3TB4 ENF4007-3T ENF4002-3B6 ENF4007-3B ENF4002-3MB4 — IEC Enclosure Type IP65 ENF16E-4PBJ ENF16E-6PBJ — — — ENF25E-4PBJ ENF25E-6PBJ — — — ENF32E-4PBJ ENF32E-6PBJ — — — ENF45E-4PBJ ENF45E-6PBJ — — — ENF63E-4PBJ ENF637-6PBJ — — — ENF30E-4PB4 ENF30E-6PB6 — — — ENF60E-4PB4 ENF60E-6PB6 — — — ENF100E-4PB4 ENF100E-6PB6 — — — — — — — — — — — — — — — — — — — — — For product data sheets, visit www.cooperbussmann.com/products/datasheet.asp Disconnects 100 Switch Type 4-pole 6-pole Transfer Bypass Mech. interlock 4-pole 6-pole Transfer Bypass Mech. interlock 4-Pole 6-Pole Transfer Bypass Mech. interlock 4-Pole 6-Pole Transfer Bypass Mech. interlock 4-Pole 6-Pole Transfer Bypass Mech. interlock 4-Pole 6-Pole Transfer Bypass Mech. interlock 4-Pole 6-Pole Transfer Bypass Mech. interlock 4-Pole 6-Pole Transfer Bypass Mech. interlock 2-Pole 4-Pole 6-Pole Transfer Bypass Mech. interlock 2-Pole 4-Pole 6-Pole Transfer Bypass Mech. interlock 2-Pole 4-Pole 6-Pole Transfer Bypass Mech. interlock 335 Disconnects A/C Disconnects — fused and non-fused Series B22__ Specifications Description: Fused and non-fused rainproof air conditioner pullout units. Dimensions: See Catalog Numbers table. Construction: NEMA 3R rainproof metal housing with weather resistant coating. Wire Range: 14-3 AWG, AL/CU Ratings: Phase: — Single, 2-wire Volts: — 240Vac Amps: — 30-60A Agency Information: UL Listed to UL 1429, C-UL Certified, UL Guide WGEW Metallic Non-Fused Disconnect Metallic Fused Disconnect Metallic Non-Fused Disconnect with GFCI receptacle. Features and Benefits • A/C disconnects meet NEC® Code Requirements under articles 440.14. GFCI units meet NEC® Code Requirements under articles 210.63, 210.8, and 406.8(B)(1). • NEMA 3R rainproof enclosures withstand outdoor environment. • Padlockable with two-position pullout handle to lock safety shield when in the ON position. (Not available on GF or NA units.) For added safety, pullout handle can be stored in the compartment in the off position. • Easy installation: knockouts on back, bottom and both sides, Cable whip versions save labor. Typical Applications • Residential, light industrial/commercial A/C and heat pump service. • Spas/whirlpools, swimming pools, pump houses • Suitable for service entrance equipment applications with field installable ground bar, kit number DPFG. B222-60NF34W non-fused with cable whip Catalog Numbers Fused Catalog Numbers B221-30F B221-30FGF B222-60F B222-60FGF Description 30A, Pullout 30A, Pullout w/ GFCI 60A, Pullout 60A, Pullout w/ GFCI Disconnect Rating 30A 30A 60A 60A Max Hp Rating 120V 240V 1.5 3 1.5 3 3 10 3 10 60A, Pullout 60A, Pullout w/ GFCI 60A, Switch 60A 60A 60A 3 3 * 60A* 60A** 3 3 Wire Range 60 or 75°C CU/AL #14-3 #14-3 #14-3 #14-3 Enclosure Type NEMA 3R NEMA 3R NEMA 3R NEMA 3R Fuse Class H or R H or R H or R H or R Approx. Dimensions (in) Height Width Depth 5 3⁄8 2 7⁄8 8 3⁄4 13 7 1⁄2 4 3⁄4 8 3⁄4 5 3⁄8 2 7⁄8 13 7 1⁄2 4 3⁄4 10 10 10 #14-3 #14-3 #14-3 NEMA 3R NEMA 3R NEMA 3R * * * 8 3⁄4 11 3⁄4 8 3⁄4 5 3⁄8 6 1⁄2 5 3⁄8 2 7⁄8 4 1⁄2 3 5⁄8 10 10 #14-3 #14-3 NEMA 3R NEMA 3R * * 14 3⁄4 14 3⁄4 12 1⁄2 12 1⁄2 4 4 Non-Fused B222-60NF B222-60NFGF B222-60NFNA Non-Fused Cable Whip B222-60NF12W B222-60NF34W 60A, Pullout w/ 1⁄2" Cable Whip 60A, Pullout w/ 3⁄4" Cable Whip Cable Whip Specifications Catalog Numbers Description B222-60NF12W 60A, Pullout w/ 1⁄2" Cable Whip B222-60NF34W 60A, Pullout w/ 3⁄4" Cable Whip Pullout Rating 60A 60A Max UpstreamWire Overcurrent Harness Protection Device Diameter 1 30A ⁄2" 3 50A ⁄4" Ground Hot Flexible Conduit Wire Size Wire Size Length (ft) #10 #10 6 #8 #10 6 * Upstream overcurrent protection device (OCPD) not to exceed 30 Amps. **Upstream overcurrent protection device (OCPD) not to exceed 50 Amps. Data Sheet: 1143 336 For product data sheets, visit www.cooperbussmann.com/products/datasheet.asp Non-Metallic Fittings 1 - 90°, 1 - Straight 1 - 90°, 1 - Straight Disconnects Fused, dead front disconnect switches 15149 Series Did You Know? All-Inclusive Elevator Disconnect Simplifies Installation Plus a Multitude of Codes and Standards Specifications Description: Fused, dead front disconnect switches Ratings: Volts: — 600Vac Amps: — 0-30A SCCR: — 200,000A RMS Sym. Dielectric SCCR: 2200V Motor Rating: 5hp Poles: 2 to 3 Agency Information: UL Recognized, file E116716 for General Industrial installations. Guide WFXV2. CSA certified, file LR37129-6. Examined under the new proposed standard UL 1429 which imparts a stricter set of test conditions than the former program that combined the applicable portions for UL 512 (Fuse Holders) and UL 98 (Enclosed Switches). Ordering Information To order, specify: 15149 + number of poles. Example: 15149-2 = 2-pole device. The contractor faced a unique situation when the luxury hotel chain chose to revamp the old warehouse versus tearing the structure down and rebuilding. The hotel complex consists of four buildings interconnected with walkways. A total of eight elevators were installed with eight Power Module switches, two per building. Each 30 HP passenger elevator is fused with Cooper Bussmann® Low-Peak® Class J LPJ-70SP fuses while each 40HP service elevator uses the Class J LPJ-90SP fuses. Data Sheet: 1141 For product data sheets, visit www.cooperbussmann.com/products/datasheet.asp 337 Disconnects Features and Benefits • Fuse holders in the pull-out head eliminate possibility of electric shock while changing fuse. • Accepts Class J fuses When the Westin Hotel chain renovated the historic Cupples Station in downtown St. Louis, the hotel’s design-and-build electrical contractor specified the Cooper Bussmann® Power Module™ elevator shunt trip disconnect. The primary reason was the savings in man-hours with everything in one box: the fire alarm, control wiring and power wiring; all the parts needed to interface with a fire alarm system in a UL 98 Listed assembly. In addition, all the codes and standards surrounding the elevator disconnecting means – electrical, elevator, fire alarm and the sprinkler system – are met, including ANSI/ASME A17.1, NFPA 72, NEC® 620.62. ELIMINATE THE GUESSWORK IN ASSEMBLY SCCR CALCULATIONS Cooper Bussmann® Services provide productivity through protection with a focus on critical issues related to enhancing the bottom line: • Downtime reduction; • Workplace safety; and • Code compliance. You can easily avoid costly shutdowns and delays that noncompliance issues cause when you have the right information. The Cooper Bussmann innovative OSCAR™ (Online ShortCircuit Current UL508A Rating) Compliance Software is the company’s most recent offering to help you comply with the new Code and standards requirements for short-circuit current ratings. Underwriters Laboratories (UL) now requires all electrical panels and assemblies manfactured to standard 508A to be marked with their SCCR. Article 409 of the 2005 National Electrical Code also mandates that industrial control panels be marked with an assembly SCCR. Getting the assembly SCCR correct can be daunting. But the company’s OSCAR compliance software easily guides users through the steps of entering the panel’s components for supply, feeder, sub-feeder and branch circuits. Based upon the component types or part numbers entered, the software determines the assembly SCCR per UL508A Supplement SB. It includes the following features. • It’s Automatic. The software determines the assembly SCCR of industrial control panel assemblies per UL508A SB based upon component types or part numbers. • It’s Simple. Just use the assembly parts list – the OSCAR compliance software is backed by a database containing more than 50,000 line item part numbers with their component SCCR. • Available Online. It’s available 24/7, 365 days a year with a one-year subscription. • Printed Documentation is Available. The OSCAR compliance software generates a spreadsheet for assembly 338 documentation of components and assembly SCCR. • It’s Continually Updated. The OSCAR compliance software is regularly updated with new part numbers, their component SCCRs, and any changes that may occur to code requirements and agency standards. • It’s Customizable. The custom device option allows users to enter specialized information not usually encountered in most assembly components. Once you have calculated your shortcircuit current rating and you find it’s too low for the application, Cooper Bussmann Services now offers SCCR design-engineering assistance to raise your rating to required levels. In an ever-changing regulatory environment, Cooper Bussmann Services can help you stay in compliance and focused on what you do best. For more information and to purchase an annual, open-ended use of the Cooper Bussmann OSCAR Compliance Software, visit www.cooperbussmann.com/SCCR or contact your Cooper Bussmann representative.