CPI 4CX250FG

The 4CX250FG/8621 has a maximum plate dissipation rating of 250 watts and a maximum input
power rating of 500 watts. The 4CX250FG/8621 is
designed for operation at a heater voltage of 26.5
volts.
Class of Operation
Characteristics
Plate Dissipation (Max.)
Screen Dissipation (Max.)
Grid Dissipation (Max.)
Frequency for Max. rating (CW)
Amplification Factor
Filament/Cathode
Voltage
Current
Capacitance
Input
Output
Feedthrough
Capacitance
Input
Output
Feedthrough
Cooling
Base
Air Socket
Air Chimney
Boiler
Length
Diameter
Weight
Maximum Ratings
Type of Service
Plate Voltage
(Volts)
Plate
Current
(Amps)
250 Watts
12 Watts
2 Watts
500 MHz
5
Oxide Coated
26.5 Volts
0.54 Amps
Grounded Cathode
15.7 pf
4.5 pf
.04 pf
Grounded Grid
13.0 pf
4.5 pf
.01 pf
Forced Air
9 Pin Special
SK-600A
SK-606
--2.46 in; 62.50 mm
1.64 in; 41.70 mm
4 oz; 113 gm
T ypical Operation
Plate
Screen
Voltage Voltage
(Volts)
(Volts)
Plate
Current
(Amps)
Drive
Output
Power Power
(Watts) (kiloWatts)
C
RF amplifier up to 175 MHz
2,000
0.25
2,000
300
.250
2.9
0.390
C
RF amplifier plate modulated up to 175 MHz
1,500
0.20
1,500
250
.200
1.7
0.235
AB1
RF linear amplifier up to 175 MHz
2,000
0.25
2,000
350
0.25
---
0.300
AB1
RF linear amplifier up to 175 MHz (AM service)
2,000
0.25
2,000
350
0.15
---
65.0
AB1
AF amplifier or modulator
2,000
0.25
2,000
350
0.50
---
0.600
The values listed above represent specified limits for the product and are subject to change. The data should be used for basic
information only. Formal, controlled specifications may be obtained from CPI for use in equipment design.
For information on this and other CPI products, visit our website at: www.cpii.com,
or contact: CPI MPP Division, Eimac Operations, 607 Hansen Way, Palo Alto, CA 94303
telephone : 1(800) 414-8823. fax : (650) 592-9988 | email : [email protected]
CPI | 4CX250FG/ 8621
CPI | 4CW50,000J
4CX250FG/8621