CPI 8930

The 8930 is electrically identical to the
4CX250R/7580W but the larger anode radiator assembly allows higher dissipation with low air flow
and pressure drop characteristics. The tube has
rugged internal construction features for reliable
operation under heavy shock or vibration conditions.
Characteristics
Plate Dissipation (Max.)
Screen Dissipation (Max.)
Grid Dissipation (Max.)
Frequency for Max. rating (CW)
Amplification Factor
Filament/Cathode
Voltage
Current
Capacitance
Input
Output
Feedthrough
Capacitance
Input
Output
Feedthrough
Cooling
Base
Air Socket
Air Chimney
Boiler
Length
Diameter
Weight
350 Watts
12 Watts
2 Watts
500 MHz
5
Oxide Coataed
6.0 Volts
2.6 Amps
Grounded Cathode
17.5 pf
4.9 pf
.03 pf
N/A
N/A
N/A
N/A
Forced Air
9-Pin Special
SK-600A
SK-646
N/A
2.46 in; 62.60 mm
2.08 in; 52.80 mm
5.5 oz; 156 gm
Maximum RatingsTypical Operation
Class of Type of ServicePlate PlatePlateScreenPlate
Operation
VoltageCurrent
Voltage VoltageCurrent
(Volts)
(Amps)
(Volts)
(Volts)
(Amps)
AB1
RF Linear Amplifier
AB1
RF Linear Amplifier AM Service
AB1AF Amplifier or Modulator
2,400
2,000
2,000
0.25
0.25
0.25
2,000
2,000
2,000
350
400
350
0.29
0.17
0.50
Drive
Output
PowerPower
(Watts) (kiloWatts)
---
4
---
0.350
0.65
0.595
The values listed above represent specified limits for the product and are subject to change. The data should be used for basic
information only. Formal, controlled specifications may be obtained from CPI for use in equipment design.
For information on this and other CPI MPP products, visit our website at: www.cpii.com,
or contact: CPI Microwave Products Division, Eimac Operation,607 Hansen Way, Palo Alto, CA 94303
telephone :
1(800) 414-8823.
fax :
(650) 592-9988 |
email :
[email protected]
CPI | 8930
4CW50,000J
8930