CRYDOM DR-ODC5

DR OUTPUT MODULES
• DIN-Rail Mountable Single Point Output Modules (35mm DIN)
• Plug into mounting boards for 0.6" modules
• Zero Voltage Turn-On for AC Modules
• 4kV Optical isolation with LED Indicator
• UL Recognized, CSA Certified, CE Compliant
• Industry standard Color Coding Black (AC Output) Red (DC Output)
• Barrier Strips Accept 14 to 28 AWG Wire.
SPECIFICATIONS (1)
Input
Part Number
Nominal Voltage VDC
Minimum Voltage VDC
Maximum Voltage VDC
Drop-out Voltage
Maximum Current (2)
Resistance (3)
DR-OAC
DR-ODC5
DR-ODC24
5-24
3.7
32
1.0
18
NA
5.0
3.5
8.0
1.0
18
250
24.0
18.0
32.0
1.0
13
2000
240 VAC
12 VAC
280 VAC
600 Vpeak
0.1mArms
200 V/usec
5.0 Arms
50 mArms
250 Apeak
1.6 V
1/2 H.P.
8.33
8.33
4000
8
-30 to 80°C
-40 to 80°C
47 to 63
1.1 oz. (31.2g)
5-48 VDC
3 VDC
60 VDC
60 VDC
10 uA
N/A
3.0 A
10 mA
5.0 A
1.6 V
N/A
0.1
0.75
4000
8
-30 to 80°C
-40 to 80°C
DC
1.1 oz. (31.2g)
5-48 VDC
3 VDC
60 VDC
60 VDC
10 uA
N/A
3.0 A
10 mA
5.0 A
1.6 V
N/A
0.1
0.75
4000
8
-30 to 80°C
-40 to 80°C
DC
1.1 oz. (31.2g)
Output
Nominal Line Voltage
Minimum Line Voltage
Maximum Line Voltage
Max Off-State Voltage (4)
Max Off-State Leakage (5)
Static Off-State dv/dt (6)
Maximum Rated On-State Current (7)
Minimum On-State Current
Max Surge Current (8)
On-State Voltage Drop or Resistance (9)
Horse POwer Rating (13)
Maximum Turn-On Time [msec] (13)
Maximum Turn-Off Time [msec] (13)
Input/Output Isolation Voltage (14)
Input/Output Capacitance
Operating Temperature Range
Storage Temperature Range
Line Frequency Range
Weight
General Notes:
(1)
(2)
(3)
(4)
(5)
(6)
(7)
(8)
(9)
(10)
(11)
(12)
.
Specifications apply to an ambient temperat ure of -30 to 80 °C unless otherwise noted.
At nominal input voltage, wit hout external LED status indicator.
+/-10% at 25°C.
Maximum 1 minute duration for OAC modules when applied as a DC v oltage rather than a peek AC voltage.
At maximum line voltage, 25°C for OAC modules, and 80°C for OD C modules.
Minimum DV/DT per EIA/NARM RS433, method RS397, DV/DT ratings do not apply to DC output models
At 40°C, derate OAC modules 58 mA/°C to 80°C, derate ODC. ODCxMC and ODC xML modules 50 mA/°C
to 80°C. CSA rati ng of OAC modules is 3.0 Arms at 40°C.
At 25°C for 1 second maxi mum duration: 1 AC cy cle for AC modules, 1 second for DC modules.
At maximum rated on-s tate current and 25°C.
At maximum line voltage, maximum rated output current, nominal input v oltage and 25°C. Switching speed
of OAC modules is based upon 60 Hz line f requency.
At 25°C for 1 second maxi mum duration.
1/3 H.P. at 240 VAC, 1/8 H.P. at 120 VAC.
For Contact information visit our web
site.
www.crydom.com
©2008 Crydom, Inc.
Specifications subject to change without notice.
MECHANICAL SPECIFICATIONS
AGENCY APPROVALS
UL E46203
CSA 38595
Rev. 072808
For Contact information visit our web
site.
www.crydom.com
©2008 Crydom, Inc.
Specifications subject to change without notice.
For Contact information visit our web
site.
www.crydom.com
©2008 Crydom, Inc.
Specifications subject to change without notice.
For Contact information visit our web
site.
www.crydom.com
©2008 Crydom, Inc.
Specifications subject to change without notice.