CT CTDD2010DLF-1205-SU1K-1

DC/DC Converters
ctparts.com
CTDD2010DLF-SU1K-1 Series
Fixed Input Isolated & Unregulated
1W Output, Single Output
Not shown at actual size.
RoHS
Compliant
SPECIFICATIONS
Part
Number
Vin
Nom.
(VDC)
Vout
(VDC)
Iout
Max.
(mA)
Iout
Min.
(mA)
Effi.
Typ.
(%)
CTDD2010DLF-0303-SU1K-1
CTDD2010DLF-0305-SU1K-1
3.3
3.3
3.0-3.6
3.0-3.6
3.3
5
300
200
30
20
72
73
CTDD2010DLF-0503-SU1K-1
CTDD2010DLF-0505-SU1K-1
CTDD2010DLF-0509-SU1K-1
CTDD2010DLF-0512-SU1K-1
CTDD2010DLF-0515-SU1K-1
5
5
5
5
5
4.5-5.5
4.5-5.5
4.5-5.5
4.5-5.5
4.5-5.5
3.3
5
9
12
15
300
200
111
83
67
30
20
12
9
7
74
78
79
80
78
CTDD2010DLF-1203-SU1K-1
CTDD2010DLF-1205-SU1K-1
CTDD2010DLF-1209-SU1K-1
CTDD2010DLF-1212-SU1K-1
CTDD2010DLF-1215-SU1K-1
12
12
12
12
12
10.8-13.2
10.8-13.2
10.8-13.2
10.8-13.2
10.8-13.2
3.3
5
9
12
15
300
200
111
83
67
30
20
12
9
7
75
78
80
81
79
CTDD2010DLF-2403-SU1K-1
CTDD2010DLF-2405-SU1K-1
CTDD2010DLF-2409-SU1K-1
CTDD2010DLF-2412-SU1K-1
CTDD2010DLF-2415-SU1K-1
24
24
24
24
24
21.6-26.4
21.6-26.4
21.6-26.4
21.6-26.4
21.6-26.4
3.3
5
9
12
15
300
200
111
83
67
30
20
12
9
7
76
79
80
81
79
Input Range
(VDC)
ISOLATION SPECIFICATIONS
Item
Test Condition
MIN
Isolation Voltage
Tested for 1 minute
1000
VDC
Isolation Resistance
Test at 500VDC
1000
MΩ
FEATURES
Efficiency: To 81%
Temperature Range: -40°C to 85°C
Isolation: 1KVDC
Package: UL94-V0
Miscellaneous: Single Output. Extremely slim with 4.5mm height.
Fixed input voltage. No heat sink required. No external component
required. Industry standard pinout. Compatible with “BB” DCP01
series. Unregulated output voltage. Custom service available.
Samples available.
TYP
MAX
Units
OUTPUT SPECIFICATIONS
Item
Test Condition
MIN
Output Power
TYP
MAX
Units
1
W
0.1
Line regulation
For Vin change of 1%
Load regulation
10% to 100% full load
10
Output voltage accuracy
See tolerance envelope graph
Temperature drift
100% full load
Output ripple & noise
20MHz bandwidth
50
Switching frequency
Full load, nominal input
100
1.2
%
15
%
0.03
%/°C
75
mVp-p
KHz
Note:
1. All specifications measured at TA=25°C, humidity<75%, nominal input voltage and rated output load
unless otherwise specified.
CHARACTERISTICS
TYPICAL CHARACTERISTICS
Temperature Derating Graph
+10%
+5%
Nominal
Voltage
Typic
a
l Load
Line
+2.5%
-2.5%
-7.5%
10%
50%
100%
Output Current(%)
CENTRAL
Technologies
01.11.07
Manufacturer of Inductors, Chokes, Coils, Beads, Transformers & Toroids
800-684-5322 Inside US
949-453-1811 Outside US
Copyright © 2006 by CT Magnetics, DBA Central Technologies. All rights reserved.
CT Magnetics reserves the right to make improvements or change specifications without notice
Output Power(%)
Tolerance Envelope Graph
Output Voltage(%)
Short Circuit Protection: 1 second
Temperature Rise at Full Load: 25°C Max. 15°C Typ.
Cooling: Free air convection
Operating Temperature Range: -40°C to +85°C
Storage Temperature Range: -55°C to +125°C
Lead Temperature: 300°C (1.5mm from case for 10 seconds)
Storage Humidity Range: < 95%
Case Material: Plastic (UL94-V0)
MTBF: >3,500,000 hours
Miscellaneous: RoHS Compliant.
120
100
80
60
Safe Operating Area
40
20
0
-40
0
40
80
120
Ambient Temperature(°C)
DC/DC Converters
ctparts.com
CTDD2010DLF-SU1K-1 Series
Fixed Input Isolated & Unregulated
1W Output, Single Output
OUTLINE DIMENSIONS & RECOMMENDED FOOTPRINT DETAILS
CTDD2010DLF-SU1K-1 Package
20.40
Side View
4.50
4.10
15.24
1 2
5 6 7
7.62
10.0
Bottom View
8
14
CTDD2010DLF-SU1K-1 Footprint
ø1.00+0.15/-0
2.54
2.54
8
14
1 2
5
6 7
Note: All pins on a 2.54mm pitch; All pin diameters are 0.50mm; all dimensions in mm
PIN CONNECTIONS
Pin
1
2
5
6
7,8
14
Function
Vin
GND
0V
+Vo
NC
NC
14
1 2
8
5 6 7
CENTRAL
Technologies
01.11.07
Manufacturer of Inductors, Chokes, Coils, Beads, Transformers & Toroids
800-684-5322 Inside US
949-453-1811 Outside US
Copyright © 2006 by CT Magnetics, DBA Central Technologies. All rights reserved.
CT Magnetics reserves the right to make improvements or change specifications without notice