Jumbo-LED ELJ-650-637 14.01.2008 rev. 01 Radiation Type Technology Case Red 3W AlInGaP/GaAs Plastic lens, metal case High-power deep-red LED in an aluminium case, with thread socket for easy handling and heat sink mounting 1,5 Ø11 Ø1,7 Ø16 Ø12,5 Description 4,5 5,08 7,9 Outline: 2 H = 12.4 mm (± 0.5) Medical appliances, remote control and optical communications, light barriers, measurement systems 8 D = 16 mm (± 0.5) 13 Thread M10 1 2 Applications Pin 1 – cathode Pin 2 – anode M10 Absolute Maximum Ratings at Tamb = 25°C, on heat sink (S ≥ 200 cm²), unless otherwise specified Parameter Test сonditions Symbol Value Unit on heat sink IF 700 mA tp≤100 µs, D = 0,05 IFM 1.6 A Power dissipation on heat sink P 3,2 W Operating temperature range on heat sink Tamb -25 to +100 °C Storage temperature range on heat sink Tstg -40 to +100 °C Junction temperature on heat sink Tj 100 °C Typ Max Unit 2.6 V DC forward current Peak forward current Electrical Characteristics Tamb = 25°C, unless otherwise specified Parameter Test conditions Symbol Min Forward voltage IF = 350 mA VF 2.2 Forward voltage* IF = 700 mA VF 2.5 V Switching time IF = 350 mA tr , t f 55/65 ns Reverse voltage IR = 10 µA VR 10 K/W Thermal resistance junction-case *only recommended on optimal heat sink RthJC 5 We reserve the right to make changes to improve technical design and may do so without further notice. Parameters can vary in different applications.All operating parameters must be validated for each customer application by the customer. EPIGAP Optoelektronik GmbH, D-12555 Berlin, Köpenicker Str.325 b, Haus 201 1 of 5 Tel.: +49-30-6576 2543, Fax : +49-30-6576 2545 Jumbo-LED ELJ-650-637 14.01.2008 rev. 01 Optical Characteristics at Tamb = 25°C, on heat sink (S ≥ 200 cm²), unless otherwise specified Test Symbol Min Parameter conditions Radiant power IF = 350 mA Φe Radiant power* IF = 700 mA Radiant intensity 30 Typ Max Unit 45 mW Φe 75 mW IF = 350 mA Ιe 130 mW/sr Radiant intensity* IF = 700 mA Ιe 220 mW/sr Luminous intensity IF = 350 mA Ιv 10 cd Luminous intensity* IF = 700 mA Ιv 15 cd Peak wavelength IF = 350 mA λp Spectral bandwidth at 50% IF = 350 mA ∆λ0.5 20 nm Viewing angle IF = 350 mA ϕ 26 deg 640 650 660 nm *only recommended on optimal heat sink Note: All measurements carried out with EPIGAP equipment, on blank aluminium heat sink, S = 180 cm², passive cooling. Measurement results and curve characteristics obtained with other heat sinks may differ. We reserve the right to make changes to improve technical design and may do so without further notice. Parameters can vary in different applications.All operating parameters must be validated for each customer application by the customer. EPIGAP Optoelektronik GmbH, D-12555 Berlin, Köpenicker Str.325 b, Haus 201 2 of 5 Tel.: +49-30-6576 2543, Fax : +49-30-6576 2545 Jumbo-LED ELJ-650-637 14.01.2008 rev. 01 We reserve the right to make changes to improve technical design and may do so without further notice. Parameters can vary in different applications.All operating parameters must be validated for each customer application by the customer. EPIGAP Optoelektronik GmbH, D-12555 Berlin, Köpenicker Str.325 b, Haus 201 3 of 5 Tel.: +49-30-6576 2543, Fax : +49-30-6576 2545 Jumbo-LED ELJ-650-637 14.01.2008 rev. 01 Remarks concerning optical radiation safety* Up to nominal forward current (<700mA) and continuous operation, this LED may be classified as LED product Class 2 , according to standard IEC 60825-1:A2. Class 2 products emit in the visible region, damaging exposure is usually prevented through avert reactions including blink reflex. It can be expected that these reactions provide sufficient protection under reasonably predictable conditions. This also implicates a direct observation of the light beam by means of optical instruments. *Note: Safety classification of an optical component mainly depends on the intended application and the way the component is being used. Furthermore, all statements made to classification are based on calculations and are only valid for this LED "as it is", and at continuous operation. Using pulsed current or altering the light beam with additional optics may lead to different safety classifications. Therefore these remarks should be taken as recommendation and guideline only. VISIBLE RADIATION Do not stare into the beam LED Class 2 accord. DIN EN/IEC 60825-1:2001-11 We reserve the right to make changes to improve technical design and may do so without further notice. Parameters can vary in different applications.All operating parameters must be validated for each customer application by the customer. EPIGAP Optoelektronik GmbH, D-12555 Berlin, Köpenicker Str.325 b, Haus 201 4 of 5 Tel.: +49-30-6576 2543, Fax : +49-30-6576 2545 Jumbo-LED ELJ-650-637 14.01.2008 rev. 01 Handling precautions To prevent damage to the LED during soldering and assembly, following precautions have to be taken into account. a) The bending point of the lead frame should be located at least 2.5 mm away from the body. b) While bending, the base of the lead frame has to be fixed with radio pliers or similar. c) To ensure an adequate strain relief, the lead frames have to be firmly fixed during soldering. d) Avoid any torsion or tensile loading of the lead frames, especially when they have been heated after being soldered. e) LEDs are static sensitive devices, so adequate handling precautions have to be taken, e.g. wearing grounding wrist straps. We reserve the right to make changes to improve technical design and may do so without further notice. Parameters can vary in different applications.All operating parameters must be validated for each customer application by the customer. EPIGAP Optoelektronik GmbH, D-12555 Berlin, Köpenicker Str.325 b, Haus 201 5 of 5 Tel.: +49-30-6576 2543, Fax : +49-30-6576 2545