ETAL P2602

PRODUCT DATA SHEET
LINE MATCHING TRANSFORMER
Features
Applications
∗
∗
∗
∗
∗
∗
∗
∗
∗
∗
∗
∗
∗
∗
Industry Standard
Lead-free (Pb-free)
RoHS compliant
12.6mm (0.5") seated height
Vacuum encapsulated
IEC 60950 and UL 60950 Certified
UL Recognized Component
Centre-tap winding
P2602
V.32bis and V.22bis modems
Line Matching
Passive hybrids
Instrumentation
Fax / modems
Voice
DESCRIPTION
P2602 is a variant of industry standard P1200 with
one centre-tapped winding.
P2602 meets international safety standards, being
vacuum encapsulated and 100% tested to
withstand 6.5kV DC. The part is completely
lead-free, compliant with RoHS Directive
2002/95/EC, and suitable for lead-free and
conventional processing.
P2602 is specifically designed to be easily
matched to both 600 ohm and complex
impedance telephone lines, using a minimum of
external components.
P2602 is certified to IEC 60950 and UL 60950.
P2602 is a UL Recognized Component and is
supported by an IEC CB Test Certificate.
P2602 is ideal for voice telecommunications
applications and for data communications to
V.32 bis (14,400 bits/second) data rates. With care,
P2602 may be used for V.34 applications to 28,800
bits/second.
ETALDOC 258/8
Page 1 of 4
February 2006
P2602
SPECIFICATIONS
Electrical
At T = 25ºC and as circuit fig. 2 unless otherwise stated.
Parameter
Conditions
Min
Typ
Max
Units
Insertion Loss
f = 2kHz, RL = 560Ω
-
-
1.5
dB
Frequency response
LF-3dB cutoff
HF-3dB cutoff
200Hz - 4kHz
10
-
-
50
±0.2
Hz
kHz
dB
Return Loss
200Hz - 4kHz
18
-
-
dB
Third Harmonic
Distortion (1)
450Hz 0dBm
-
-72
-60
dBm
Balance
DC – 5kHz
Method TG25
80
-
-
dB
-
-
10
65
V rms
V peak
3.88
5.5
-
-
kVrms
kV
-25
-40
-
+85
+125
ºC
ºC
120
-
148
Ω
14.5
-
18
mH
Saturation
Excitation 50Hz
250V rms.
Output voltage
across line
Voltage
isolation (2)
50Hz
DC
Operating range:
Functional
Storage
Ambient temperature
Lumped equivalent circuit parameters as Fig. 1
DC resistance, RDC (3)(5)
Sum of windings
Leakage inductance ΔL
Shunt inductance Lp (4)
10mV 200Hz
10mV1kHz
2.8
-
8
2
-
H
H
Shunt loss Rp (4)
10mV 200Hz
10mV 1kHz
5
7
-
-
kΩ
kΩ
Notes
1. Third harmonic typically exceeds other
harmonics by 20dB.
2. Components are 100% tested at 6.5kV DC.
3. Caution: do not pass DC through windings.
Telephone line current, etc. must be diverted
using choke or semiconductor line hold
circuit.
4. At signal levels greater than 100mV, Lp will
increase and Rp will decrease slightly but the
effect is usually favourable to the return loss
characteristic.
5. Resistance imbalance between the two
ETALDOC 258/8
Page 2 of 4
Equivalent Circuit
Fig. 1
½ ΔL ½ RDC
½ RDC ½ ΔL
IDEAL
1:1
February 2006
P2602
halves of the tapped winding will not be
greater than 5Ω.
MATCHING RECOMMENDATIONS
600Ω MATCH
EUROPEAN CTR21 COMPLEX MATCH
Recommended Circ uit
Recommended Circ uit
Fig. 2
Fig. 3
600
+ 50%
6.8μF _ 20% *
150nF
270
27nF
+_ 5%
LINE
33nF
+_ 5%
560
+_ 2%
750
2.2μF
(150nF)
100nF
56nF
750
(680)
150
(220)
LINE
* If return loss > 16dB, 300Hz - 4kHz is ac ceptable, bloc king
capacitor may be relaxed to 4.7μF +_ 50%
20%
Figure 3 gives flat RX and TX responses against the
CTR21 complex reference impedance (typically
around ±0.5dB 300Hz - 3.4kHz). Return loss is
typically better than 20dB. The circuit values in
parentheses give optimum flatness at a small
sacrifice in return loss.
For circuits with existing board drillings, figure 4
gives good return loss (>20dB) and RX flatness
against the CTR21 complex reference impedance,
but TX flatness is degraded by the use of this
topology.
Fig. 4
150nF
270
750
LINE
2.2μF
68nF
330
27nF
820
CONSTRUCTION
e2
ETALDOC 258/8
Page 3 of 4
February 2006
P2602
Dimensions shown are in millimetres (inches).
Geometric centres of outline and pin grid coincide within a tolerance circle of 0.6mm
ETALDOC 258/8
Page 4 of 4
February 2006
P2602
SAFETY
CERTIFICATION
Constructed in accordance with IEC 60950-1:2001,
EN 60950-1:2001 and UL 60950-1 First Edition,
supplementary insulation, 250Vrms maximum
working voltage, flammability class V-0.
Distances through solid insulation 0.4mm
minimum.
Certified under the IEC CB scheme (Certificate
DK-9431) to IEC 60950-1:2001, sub-clauses 1.5,
1.5.1, 1.5.2, 1.7, 1.7.1, 2, 2.9, 2.9.1, 2.9.2, 2.9.3,
2.10, 2.10.1, 2.10.2, 2.10.3, 2.10.3.1, 2.10.3.3,
2.10.4, 2.10.5, 2.10.5.1, 2.10.5.4, 4, 4.7, 4.7.1,
4.7.3, 4.7.3.1, 4.7.3.4, 5, 5.2, 5.2.1, and 5.2.2 for a
maximum working voltage of 250Vrms, nominal
mains supply voltage not exceeding 300Vrms and
a maximum operating temperature of 85ºC in
Pollution Degree 2 environments, supplementary
insulation, including national differences for
Denmark, Finland, Germany, Norway, Sweden,
Switzerland, USA, Canada and UK.
Recognized under the Component Recognition
Program of Underwriters Laboratories Inc. to US and
Canadian
requirements
CAN/CSA
C22.2
No. 60950-1-03/UL60950-1, First Edition, based on
IEC 60950-1, First Edition, maximum working voltage
250Vrms, Pollution Degree 2, reinforced insulation.
UL File number E203175.
Additionally, ETAL certifies all transformers as providing
voltage isolation of 3.88kVrms, 5.5kV DC minimum.
All shipments are supported by a certificate of
conformity to current applicable safety standards.
ABSOLUTE MAXIMUM RATINGS
COPYRIGHT
(Ratings of components independent of circuit).
Short term isolation voltage (1s)
4.6kVrms,
6.5kV DC
DC polarizing current
100μA
Storage temperature
-40ºC to
+125ºC
Lead temperature, 10s
260ºC
E203175
ETALDOC 258/8
ETAL, P1200 and P2602 are Trade Marks of
Profec Technologies Ltd.
The Trade Mark ETAL is registered at the UK
Trade Marks Registry.
Profec Technologies Ltd. is the owner of the
design right under the Copyright Designs and
Patents Act 1988 and no rights or licences are
hereby granted or implied to any third party.
© 1996 - 2006 Profec Technologies Ltd.
Reproduction prohibited.
ETAL Group Oy, Kuormatie 14, FIN-03101, Nummela
Telephone: +358 (0)20 7500 330
Fax: +358 (0)20 7500 333
Website: www.etalgroup.com
Email: [email protected]
Page 5 of 4
ISO 9001
FM 25326
February 2006