DESCRIPTION
P1200 is the transformer of choice in medium-speed
applications where good performance in a robust
resin encapsulated package is required at a most
competitive price.
P1200 is specifically designed to be easily
matched to both 600 ohm and complex
impedance telephone lines, using a minimum of
external components.
P1200 meets international safety standards, being
vacuum encapsulated and 100% tested to
withstand 6.5kV DC. The part is completely
lead-free, compliant with RoHS Directive
2002/95/EC, and suitable for lead-free and
conventional processing.
P1200 is certified to IEC 60950 and UL60950.
P1200 is a UL Recognized Component and is
supported an IEC CB Test Certificate.
P1200 is ideal for voice telecommunications
applications and for data communications to
V.32 bis (14,400 bits/second) data rates. With care,
P1200 may be used for V.34 applications to 28,800
bits/second.
ETALDOC 71/17
Page 1 of 4
April 2005
P1200
SPECIFICATIONS
Electrical
At T = 25ºC and as circuit fig. 2 unless otherwise stated.
Parameter
Conditions
Min
Typ
Max
Units
Insertion Loss
f = 2kHz, RL = 560Ω
-
-
1.5
dB
Frequency response
LF-3dB cutoff
HF-3dB cutoff
200Hz - 4kHz
10
-
-
50
±0.2
Hz
kHz
dB
Return Loss
200Hz - 4kHz
18
-
-
dB
Third Harmonic
Distortion (1)
450Hz 0dBm
-
-72
-60
dBm
Balance
DC – 5kHz
Method TG25
80
-
-
dB
-
-
10
65
V rms
V peak
3.88
5.5
-
-
kVrms
kV
0
-40
-
+70
+125
ºC
ºC
120
-
148
Ω
14.5
-
18
mH
Saturation
Excitation 50Hz
250V rms.
Output voltage
across line
Voltage
isolation (2)
50Hz
DC
Operating range:
Functional
Storage
Ambient temperature
Lumped equivalent circuit parameters as Fig. 1
DC resistance, RDC (3)
Sum of windings
Leakage inductance ΔL
Shunt inductance Lp (4)
10mV 200Hz
10mV 1kHz
2.8
-
4
2
7
-
H
H
Shunt loss Rp (4)
10mV 200Hz
10mV 1kHz
5
7
-
-
kΩ
kΩ
Notes
Equivalent Circuit
1. Third harmonic typically exceeds other
harmonics by 20dB.
2. Components are 100% tested at 6.5kV DC.
3. Caution: do not pass DC through windings.
Telephone line current, etc. must be diverted
using choke or semiconductor line hold
circuit.
4. At signal levels greater than 100mV, Lp will
increase and Rp will decrease slightly but the
effect is usually favourable to the return loss
characteristic.
ETALDOC 71/17
Page 2 of 4
Fig. 1
½ L ½R
LINE
½R
½ L
IDEAL
1:1
EQUIPMENT
April 2005
P1200
MATCHING RECOMMENDATIONS
600Ω MATCH
EUROPEAN CTR21 COMPLEX MATCH
Recommended Circ uit
Recommended Circ uit
Fig. 2
Fig. 3
600
+ 50%
6.8μF _ 20% *
150nF
270
27nF
+_ 5%
LINE
33nF
+_ 5%
560
+_ 2%
2.2μF
(150nF)
100nF
56nF
750
(680)
750
150
(220)
LINE
* If return loss > 16dB, 300Hz - 4kHz is ac ceptable, bloc king
capacitor may be relaxed to 4.7μF +_ 50%
20%
Figure 3 gives flat RX and TX responses against the
CTR21 complex reference impedance (typically
around ±0.5dB 300Hz - 3.4kHz). Return loss is
typically better than 20dB. The circuit values in
parentheses give optimum flatness at a small
sacrifice in return loss.
For circuits with existing board drillings, figure 4
gives good return loss (>20dB) and RX flatness
against the CTR21 complex reference impedance,
but TX flatness is degraded by the use of this
topology.
Fig. 4
150nF
270
750
2.2μF
68nF
330
27nF
820
LINE
CONSTRUCTION
e2
Dimensions shown are in millimetres (inches).
Geometric centres of outline and pin grid coincide within a tolerance circle of 0.6mm
ETALDOC 71/17
Page 3 of 4
April 2005
P1200
Windings may be used interchangeably as primary or secondary.
ETALDOC 71/17
Page 4 of 4
April 2005
P1200
SAFETY
CERTIFICATION
Constructed in accordance with IEC 60950-1,
EN 60950-1, supplementary insulation, and
UL 60950-1, reinforced insulation, 250Vrms
maximum working voltage, flammability class V-0.
Distances through solid insulation 0.4mm
minimum.
Certified under the IEC CB scheme (Certificate
DK-8570) to IEC 60950-1-2001, sub-clauses 1.5, 1.5.1,
1.5.2, 1.7.1, 2.9, 2.9.1, 2.9.2, 2.9.3, 2.10, 2.10.1, 2.10.2,
2.10.3, 2.10.3.1, 2.10.3.3, 2.10.4, 2.10.5, 2.10.5.1,
2.10.5.2, 2.10.5.4, 4.7, 4.7.1 (classV-1), 4.7.3, 4.7.3.1,
4.7.3.4, 5.2, 5.2.1, 5.2.2, 6.1.2.1 (Finland, Norway,
Sweden national deviations) for a maximum working
voltage of 250Vrms, nominal mains supply voltage not
exceeding 300Vrms and a maximum operating
temperature of 70ºC in Pollution Degree 2
environments, supplementary insulation.
Recognized under the Component Recognition
Program of Underwriters Laboratories Inc. to US and
Canadian
requirements
CAN/CSA
C22.2
No. 60950-1-03/UL60950-1, First Edition, based on
IEC 60950-1, First Edition, maximum working voltage
250Vrms, Pollution Degree 2, reinforced insulation.
UL File number E203175.
Additionally, Profec Technologies certifies all
transformers as providing voltage isolation of
3.88kVrms, 5.5kV DC minimum. All shipments are
supported by a certificate of conformity to current
applicable safety standards.
ABSOLUTE MAXIMUM RATINGS
COPYRIGHT
(Ratings of components independent of circuit).
Short term isolation voltage (1s)
4.6kVrms,
6.5kV DC
DC current
100μA
Storage temperature
-40ºC to
+125ºC
Lead temperature, 10s
260ºC
E203175
ETALDOC 71/17
ETAL, P1200, are Trade Marks of Profec
Technologies Ltd.
The Trade Mark ETAL is registered at the UK
Trade Marks Registry.
Profec Technologies Ltd. is the owner of the
design right under the Copyright Designs and
Patents Act 1988 and no rights or licences are
hereby granted or implied to any third party.
© 1996-2005 Profec Technologies Ltd.
Reproduction prohibited.
ETAL Group Oy, Kuormatie 14, FIN-03101, Nummela
Telephone: +358 (0)20 7500 330
Fax: +358 (0)20 7500 333
Website: www.etalgroup.com
Email: [email protected]
Page 5 of 4
ISO 9001
FM 25326
April 2005