EXTECH DV40

EXTECH INSTRUMENTS CORPORATION (A FLIR COMPANY) warrants this
instrument to be free of defects in parts and workmanship for one year from
date of shipment (a six month limited warranty applies on sensors and cables).
If it should become necessary to return the instrument for service during or
beyond the warranty period, contact the Customer Service Department at
(781) 890-7440 ext. 210 for authorization or visit our website at
www.extech.com (click on ‘Contact Extech’ and go to ‘Service Department’ to
request an RA number). A Return Authorization (RA) number must be issued
before any product is returned to Extech. The sender is responsible for
shipping charges, freight, insurance and proper packaging to prevent damage
in transit. This warranty does not apply to defects resulting from action of the
user such as misuse, improper wiring, operation outside of specification,
improper maintenance or repair, or unauthorized modification. Extech
specifically disclaims any implied warranties or merchantability or fitness for a
specific purpose and will not be liable for any direct, indirect, incidental or
consequential damages. Extech's total liability is limited to repair or
replacement of the product. The warranty set forth above is inclusive and no
other warranty, whether written or oral, is expressed or implied.
Warranty
1. Access the battery compartment by gently pressing the pocket
clip release latch and sliding the cover down.
2. Insert three LR44 button batteries (observe polarity).
3. Replace and latch the cover
NOTE: If your meter does not work properly, check the battery to
make sure that it still good and that it is properly
inserted.
BATTERY INSTALLATION
Double insulation
This symbol, adjacent to a terminal, indicates that, under normal use,
hazardous voltages may be present
This symbol, adjacent to another symbol or terminal, indicates the user
the user must refer to the manual for further information.
CAUTION: Read, understand and follow Safety Rules and Operating
Instructions in this manual before using this product.
Do not attempt to repair this unit. There are no user serviceable parts.
Do not expose the unit to extreme temperatures or high humidity
Do not use the unit if it is wet or damaged
Do not apply more than the rated voltage between the probe tip and ground.
Do not operate with the case open
WARNING: Risk of Electrocution. Keep hands and fingers on the body of the
probe and away from the probe tip
1.
2.
3.
4.
5.
6.
7.
8.
WARNING: Risk of Electrocution. Before use, always test the Voltage Detector
on a known live circuit to verify proper operation
The cone tip will light up for approximately 2 seconds and then turn off,
ensuring that the LED is working correctly. Continue holding the NCV button.
Place the probe tip near the hot conductor or next to the hot side of the
electrical outlet.
If AC voltage is present, the detector cone will produce a steady constant
glow.
2.
3.
4.
Release the MEASURE button, “HOLD” will appear and the last measured
value will remain in the display until the meter turns off (approximately 30
seconds).
Displaying °F or °C
The temperature units selection switch
is located in the battery compartment.
The meter will turn ON, “SCAN” will flash in the display and the measured
surface temperature will appear in the display.
4.
PRESS and HOLD the IR button.
3.
Point the IR sensor toward object to be measured,
2.
1.
NOTE: The IR thermometer has a distance to target ratio of 1:1. For the most
accurate readings position the meter as close as possible to the target..
IR TEMPERATURE MEASUREMENTS
NOTE: The detector is designed with high sensitivity. Static electricity or other
sources of energy will randomly trip the sensor. This is normal operation.
NOTE: The conductors in electrical cord sets are often twisted. For best results, rub
the probe tip along a length of the cord to assure placing the tip in close proximity
to the live conductor.
PRESS and HOLD the NCV button.
1.
WARNING: Risk of Electrocution. Before use, always test the Voltage Detector
on a known live circuit to verify proper operation
AC VOLTAGE DETECTION
.IRT measure button
LCD display.
IRT port
Battery compartment
NCV detector
NCV indicator cone
NCV measurement button
Battery compartment release latch.
Operating Instructions
Safety
Non-Contact
Voltage Detector and IR Thermometer
User’s Guide DV40
0.95 fixed
1:1
Resolution
Emissivity settings
Distance to Target Ratio
Support Hotline (781) 890-7440
Tech support: Ext. 200; Email: [email protected]
Repair/Returns: Ext. 210; Email: [email protected]
Specifications subject to change without notice
Extech Instruments Corporation : www.extech.com
285 Bear Hill Rd. Waltham, MA 02451
For indoor use and in accordance with
Overvoltage Category IV-600V, Category
III 1000V, Pollution Degree 2.
V3.0 6/08
Copyright © 2008 Extech Instruments Corporation
All rights reserved including the right of reproduction in whole or in part in any form
Safety
Operating below 2000 meters
6.25x1” (159x25mm) / 1.25oz / 35.5g
Weight
Dimensions/Weight
1.25oz. / 35.5g
Power Supply
Altitude
3 LR44 or A76 button batteries
Operating Humidity
14 to 140°F (-10 to 60°C)
10% to 80% RH
Operating Temperature
Storage Temperature
9999 count LCD display
32 to 122°F (0 to 50°C)
Display
Voltage Sensitivity
Bandwidth
Detection distance
General
50V to 1000V AC
50/60Hz
1” @ 105V
±8ºF/4ºC
-20 to -8°F (-30 to -10°C)
Non-Contact Voltage Detector
± 2.0% of reading or ±4ºF/2ºC
whichever is greater
-8 to 445°F (-10 to 230°C)
Accuracy
-20 to 445°F (-30 to 230°C)
0.1°F/C
Range
IR Thermometer
Specifications