FERROXCUBE E80-3C90-E400

FERROXCUBE
DATA SHEET
E80/38/20
E cores and accessories
Supersedes data of September 2004
2008 Sep 01
Ferroxcube
E cores and accessories
E80/38/20
CORE SETS
Effective core parameters
80 ±1.6
handbook, halfpage
SYMBOL
PARAMETER
VALUE
59.1 min.
19.8
±0.4
UNIT
Σ(I/A)
core factor (C1)
0.470
mm−1
Ve
effective volume
72300
mm3
Ie
effective length
184
mm
Ae
effective area
392
mm2
Amin
minimum area
392
mm2
m
mass of core half
≈ 180
g
28.2
±0.3
38.1
±0.3
19.8
±0.4
CBW078
Dimensions in mm.
Fig.1 E80/38/20 core half.
Core halves
AL measured in combination with a non-gapped core half, clamping force for AL measurements 60 ±20 N, unless stated
otherwise.
TOTAL AIR GAP
(µm)
AL
(nH)
µe
100 ±5%(1)
≈ 37
≈ 10800
E80/38/20-3C90-E100
160 ±5%(1)
≈ 60
≈ 5540
E80/38/20-3C90-E160
250
±5%(1)
≈ 93
≈ 2900
E80/38/20-3C90-E250
315
±5%(1)
≈ 118
≈ 2120
E80/38/20-3C90-E315
400
±8%(1)
≈ 149
≈ 1540
E80/38/20-3C90-E400
≈ 235
≈ 860
E80/38/20-3C90-E630
5070 ±25%
≈ 1890
≈0
E80/38/20-3C90
3C92
3600 ±25%
≈ 1350
≈0
E80/38/20-3C92
3C94
5070 ±25%
≈ 1890
≈0
E80/38/20-3C94
3C95
6730 ±25%
≈ 2510
≈0
E80/38/20-3C95
100
±5%(1)
≈ 37
≈ 10800
E80/38/20-3F3-E100
160
±5%(1)
≈ 60
≈ 5540
E80/38/20-3F3-E160
250
±5%(1)
≈ 93
≈ 2900
E80/38/20-3F3-E250
315 ±5%(1)
≈ 118
≈ 2120
E80/38/20-3F3-E315
400
±8%(1)
≈ 149
≈ 1540
E80/38/20-3F3-E400
630
±10%(1)
≈ 235
≈ 860
E80/38/20-3F3-E630
≈ 1710
≈0
GRADE
3C90
630 ±10%(1)
3F3
4590 ±25%
2008 Sep 01
2
TYPE NUMBER
E80/38/20-3F3
Ferroxcube
E cores and accessories
E80/38/20
Note
1. Measured in combination with an equal gapped core half.
Properties of core sets under power conditions
B (mT) at
CORE LOSS (W) at
H = 250 A/m;
f = 25 kHz;
T = 100 °C
f = 25 kHz;
ˆ
B = 200 mT;
T = 100 °C
f = 100 kHz;
ˆ = 100 mT;
B
T = 100 °C
f = 100 kHz;
ˆ = 200 mT;
B
T = 25 °C
f = 100 kHz;
ˆ = 200 mT;
B
T = 100 °C
f = 400 kHz;
ˆ = 50 mT;
B
T = 100 °C
3C90
≥320
≤ 7.2
≤ 10
−
−
−
3C92
≥370
−
≤ 7.5
−
≤ 45
−
3C94
≥320
−
≤ 7.5
−
≤ 45
−
3C95
≥320
−
−
≤ 45.5
≤ 43.4
−
3F3
≥320
−
≤ 9.0
−
−
≤ 15.4
GRADE
2008 Sep 01
3
Ferroxcube
E cores and accessories
E80/38/20
DATA SHEET STATUS DEFINITIONS
DATA SHEET
STATUS
PRODUCT
STATUS
DEFINITIONS
Preliminary
specification
Development
This data sheet contains preliminary data. Ferroxcube reserves the right to
make changes at any time without notice in order to improve design and
supply the best possible product.
Product specification
Production
This data sheet contains final specifications. Ferroxcube reserves the right
to make changes at any time without notice in order to improve design and
supply the best possible product.
DISCLAIMER
Life support applications  These products are not designed for use in life support appliances, devices, or systems
where malfunction of these products can reasonably be expected to result in personal injury. Ferroxcube customers
using or selling these products for use in such applications do so at their own risk and agree to fully indemnify Ferroxcube
for any damages resulting from such application.
PRODUCT STATUS DEFINITIONS
STATUS
INDICATION
DEFINITION
Prototype
These are products that have been made as development samples for the purposes of
technical evaluation only. The data for these types is provisional and is subject to
change.
Design-in
These products are recommended for new designs.
Preferred
These products are recommended for use in current designs and are available via our
sales channels.
Support
These products are not recommended for new designs and may not be available
through all of our sales channels. Customers are advised to check for availability.
2008 Sep 01
4