FERROXCUBE DATA SHEET E80/38/20 E cores and accessories Supersedes data of September 2004 2008 Sep 01 Ferroxcube E cores and accessories E80/38/20 CORE SETS Effective core parameters 80 ±1.6 handbook, halfpage SYMBOL PARAMETER VALUE 59.1 min. 19.8 ±0.4 UNIT Σ(I/A) core factor (C1) 0.470 mm−1 Ve effective volume 72300 mm3 Ie effective length 184 mm Ae effective area 392 mm2 Amin minimum area 392 mm2 m mass of core half ≈ 180 g 28.2 ±0.3 38.1 ±0.3 19.8 ±0.4 CBW078 Dimensions in mm. Fig.1 E80/38/20 core half. Core halves AL measured in combination with a non-gapped core half, clamping force for AL measurements 60 ±20 N, unless stated otherwise. TOTAL AIR GAP (µm) AL (nH) µe 100 ±5%(1) ≈ 37 ≈ 10800 E80/38/20-3C90-E100 160 ±5%(1) ≈ 60 ≈ 5540 E80/38/20-3C90-E160 250 ±5%(1) ≈ 93 ≈ 2900 E80/38/20-3C90-E250 315 ±5%(1) ≈ 118 ≈ 2120 E80/38/20-3C90-E315 400 ±8%(1) ≈ 149 ≈ 1540 E80/38/20-3C90-E400 ≈ 235 ≈ 860 E80/38/20-3C90-E630 5070 ±25% ≈ 1890 ≈0 E80/38/20-3C90 3C92 3600 ±25% ≈ 1350 ≈0 E80/38/20-3C92 3C94 5070 ±25% ≈ 1890 ≈0 E80/38/20-3C94 3C95 6730 ±25% ≈ 2510 ≈0 E80/38/20-3C95 100 ±5%(1) ≈ 37 ≈ 10800 E80/38/20-3F3-E100 160 ±5%(1) ≈ 60 ≈ 5540 E80/38/20-3F3-E160 250 ±5%(1) ≈ 93 ≈ 2900 E80/38/20-3F3-E250 315 ±5%(1) ≈ 118 ≈ 2120 E80/38/20-3F3-E315 400 ±8%(1) ≈ 149 ≈ 1540 E80/38/20-3F3-E400 630 ±10%(1) ≈ 235 ≈ 860 E80/38/20-3F3-E630 ≈ 1710 ≈0 GRADE 3C90 630 ±10%(1) 3F3 4590 ±25% 2008 Sep 01 2 TYPE NUMBER E80/38/20-3F3 Ferroxcube E cores and accessories E80/38/20 Note 1. Measured in combination with an equal gapped core half. Properties of core sets under power conditions B (mT) at CORE LOSS (W) at H = 250 A/m; f = 25 kHz; T = 100 °C f = 25 kHz; ˆ B = 200 mT; T = 100 °C f = 100 kHz; ˆ = 100 mT; B T = 100 °C f = 100 kHz; ˆ = 200 mT; B T = 25 °C f = 100 kHz; ˆ = 200 mT; B T = 100 °C f = 400 kHz; ˆ = 50 mT; B T = 100 °C 3C90 ≥320 ≤ 7.2 ≤ 10 − − − 3C92 ≥370 − ≤ 7.5 − ≤ 45 − 3C94 ≥320 − ≤ 7.5 − ≤ 45 − 3C95 ≥320 − − ≤ 45.5 ≤ 43.4 − 3F3 ≥320 − ≤ 9.0 − − ≤ 15.4 GRADE 2008 Sep 01 3 Ferroxcube E cores and accessories E80/38/20 DATA SHEET STATUS DEFINITIONS DATA SHEET STATUS PRODUCT STATUS DEFINITIONS Preliminary specification Development This data sheet contains preliminary data. Ferroxcube reserves the right to make changes at any time without notice in order to improve design and supply the best possible product. Product specification Production This data sheet contains final specifications. Ferroxcube reserves the right to make changes at any time without notice in order to improve design and supply the best possible product. DISCLAIMER Life support applications These products are not designed for use in life support appliances, devices, or systems where malfunction of these products can reasonably be expected to result in personal injury. Ferroxcube customers using or selling these products for use in such applications do so at their own risk and agree to fully indemnify Ferroxcube for any damages resulting from such application. PRODUCT STATUS DEFINITIONS STATUS INDICATION DEFINITION Prototype These are products that have been made as development samples for the purposes of technical evaluation only. The data for these types is provisional and is subject to change. Design-in These products are recommended for new designs. Preferred These products are recommended for use in current designs and are available via our sales channels. Support These products are not recommended for new designs and may not be available through all of our sales channels. Customers are advised to check for availability. 2008 Sep 01 4