FERROXCUBE P66

FERROXCUBE
DATA SHEET
P66/56
P cores and accessories
Supersedes data of September 2004
2008 Sep 01
Ferroxcube
P cores and accessories
P66/56
CORE SETS
Effective core parameters
SYMBOL
PARAMETER
VALUE
UNIT
Σ(I/A)
core factor (C1)
0.172
mm−1
Ve
effective volume
88200
mm3
Ie
effective length
123
mm
Ae
effective area
717
mm2
Amin
minimum area
591
mm2
m
mass of set
≈ 550
g
7.26
± 0.25
54.51
± 1.02
66.29
± 1.19
28.19
± 0.61
6.5 ± 0.15
43.28
± 0.5
57.3
± 0.5
MGC156
Dimensions in mm.
Fig.1 P66/56 core set.
Core sets for general purpose transformers and power applications
Clamping force for AL measurements, 1000 ±300 N.
AL
(nH)
GRADE
AIR GAP
(µm)
µe
TYPE NUMBER
3C81
18200 ±25%
≈ 2490
≈0
P66/56-3C81
3C91
18200 ±25%
≈ 2490
≈0
P66/56-3C91
3F3
12350 ±25%
≈ 1690
≈0
P66/56-3F3
Properties of core sets under power conditions
B (mT) at
CORE LOSS (W) at
H = 250 A/m;
f = 25 kHz;
T = 100 °C
f = 25 kHz;
ˆ = 200 mT;
B
T = 100 °C
f = 100 kHz;
ˆ = 100 mT;
B
T = 100 °C
f = 100 kHz;
ˆ = 200 mT;
B
T = 100 °C
f = 400 kHz;
ˆ = 50 mT;
B
T = 100 °C
3C81
≥320
≤ 25
−
−
−
3C91
≥315
−
3F3
≥315
−
GRADE
≤
≤ 10
Note
1. Measured at 60 °C.
2008 Sep 01
4.7(1)
1031
≤
33(1)
−
−
≤ 20
Ferroxcube
P cores and accessories
P66/56
COIL FORMERS
General data CP-P66/56 coil former
PARAMETER
SPECIFICATION
Coil former material
phenolformaldehyde (PF), glass reinforced, flame retardant in accordance with
“UL 94V-0” ; UL file number E59481
Maximum operating temperature
180 °C, “IEC 60085”, class H
41.5
0
−0.3
1.4
∅29 +0.4
0
53 0
−0.5
5
∅31.9
± 0.2
MFP178
Dimensions in mm.
Fig.2 Coil former: CP-P66/56-1S-C.
Winding data for CP-P66/56 coil former
NUMBER OF
SECTIONS
WINDING
AREA
(mm2)
MINIMUM
WINDING
WIDTH
(mm)
AVERAGE
LENGTH OF
TURN
(mm)
1
400
38.4
130
2008 Sep 01
1032
TYPE NUMBER
CP-P66/56-1S-C
Ferroxcube
P cores and accessories
P66/56
DATA SHEET STATUS DEFINITIONS
DATA SHEET
STATUS
PRODUCT
STATUS
DEFINITIONS
Preliminary
specification
Development
This data sheet contains preliminary data. Ferroxcube reserves the right to
make changes at any time without notice in order to improve design and
supply the best possible product.
Product specification
Production
This data sheet contains final specifications. Ferroxcube reserves the right
to make changes at any time without notice in order to improve design and
supply the best possible product.
DISCLAIMER
Life support applications  These products are not designed for use in life support appliances, devices, or systems
where malfunction of these products can reasonably be expected to result in personal injury. Ferroxcube customers
using or selling these products for use in such applications do so at their own risk and agree to fully indemnify Ferroxcube
for any damages resulting from such application.
PRODUCT STATUS DEFINITIONS
STATUS
INDICATION
DEFINITION
Prototype
These are products that have been made as development samples for the purposes of
technical evaluation only. The data for these types is provisional and is subject to
change.
Design-in
These products are recommended for new designs.
Preferred
These products are recommended for use in current designs and are available via our
sales channels.
Support
These products are not recommended for new designs and may not be available
through all of our sales channels. Customers are advised to check for availability.
2008 Sep 01
1033