FERROXCUBE P18-3F3-A630

FERROXCUBE
DATA SHEET
P18/11/I
P cores and accessories
Supersedes data of September 2004
2008 Sep 01
Ferroxcube
P cores and accessories
P18/11/I
CORE SETS
Effective core parameters
SYMBOL
PARAMETER
VALUE
UNIT
Σ(I/A)
core factor (C1)
0.560
mm−1
Ve
effective volume
1270
mm3
Ie
effective length
26.7
mm
Ae
effective area
47.5
mm2
Amin
minimum area
37.5
mm2
m
mass of set
≈7
g
13.4 ± 0.3
handbook, halfpage
7.4
3.8
± 0.15 ± 0.6
15.1 17.9
± 0.25 ± 0.3
0.5
± 0.13
7.2
10.6
+0.4/−0 ± 0.15
MGB573
Dimensions in mm.
Fig.1 P18/11/I core set.
Core sets for general purpose transformers and power applications
Clamping force for AL measurements, 30 ±10 N.
GRADE
3C81
3C91
3F3
AL
(nH)
TYPE NUMBER
160 ±3%
≈ 72
≈ 450
P18/11/I-3C81-A160
250 ±3%
≈ 112
≈ 260
P18/11/I-3C81-A250
315 ±3%
≈ 141
≈ 200
P18/11/I-3C81-A315
400 ±3%
≈ 179
≈ 150
P18/11/I-3C81-A400
630 ±5%
≈ 282
≈ 90
P18/11/I-3C81-A630
4200 ±25%
≈ 1880
≈0
P18/11/I-3C81
4200 ±25%
≈ 1880
≈0
P18/11/I-3C91
160 ±3%
≈ 72
≈ 450
P18/11/I-3F3-A160
250 ±3%
≈ 112
≈ 260
P18/11/I-3F3-A250
315 ±3%
≈ 141
≈ 200
P18/11/I-3F3-A315
400 ±3%
≈ 179
≈ 150
P18/11/I-3F3-A400
630 ±5%
≈ 282
≈ 90
P18/11/I-3F3-A630
≈ 1390
≈0
3110 ±25%
2008 Sep 01
AIR GAP
(µm)
µe
976
P18/11/I-3F3
Ferroxcube
P cores and accessories
P18/11/I
Properties of core sets under power conditions
B (mT) at
CORE LOSS (W) at
H = 250 A/m;
f = 25 kHz;
T = 100 °C
f = 25 kHz;
ˆ = 200 mT;
B
T = 100 °C
f = 100 kHz;
ˆ = 100 mT;
B
T = 100 °C
f = 100 kHz;
ˆ = 200 mT;
B
T = 100 °C
f = 400 kHz;
ˆ = 50 mT;
B
T = 100 °C
3C81
≥320
≤ 0.3
−
−
−
3C91
≥315
−
3F3
≥315
−
GRADE
≤
≤
0.08(1)
−
0.5 (1)
≤ 0.14
−
≤ 0.24
Note
1. Measured at 60 °C.
BOBBINS AND ACCESSORIES
Coil formers, winding data and mounting parts are equal to those of “P18/11”, but “area product” is different.
Winding data and area product (for P18/11/I) for CP-P18/11 coil former
NUMBER OF
SECTIONS
WINDING
AREA
(mm2)
MINIMUM
WINDING
WIDTH
(mm)
AVERAGE
LENGTH OF
TURN
(mm)
AREA
PRODUCT
Ae x Aw
(mm4)
1
17.1
5.7
36.6
812
CP-P18/11-1S
2
2 × 7.95
2 × 2.65
36.6
2 x 378
CP-P18/11-2S
3
3 × 4.95
3 × 1.6
36.6
3 x 235
CP-P18/11-3S
TYPE NUMBER
Winding data and area product (for P18/11/I) for 6-pins P18/11 coil former for PCB mounting
NUMBER
OF
SECTIONS
MINIMUM
WINDING
AREA
(mm2)
NOMINAL
WINDING
WIDTH
(mm)
AVERAGE
LENGTH OF
TURN
(mm)
LENGTH
OF PINS
(mm)
AREA
PRODUCT
Ae x Aw
(mm4)
1
16.8
6.0
36.7
4.4
798
CPV-P18/11-1S-6PD
1
16.8
6.0
36.7
6.8
798
CPV-P18/11-1S-6PDL
2
2 × 7.61
2 × 2.8
36.7
4.4
2 x 361
CPV-P18/11-2S-6PD
2
2 × 7.61
2 × 2.8
36.7
6.8
2 x 361
CPV-P18/11-2S-6PDL
3
3 × 4.58
3 × 1.7
36.7
4.4
3 x 218
CPV-P18/11-3S-6PD
3
3 × 4.58
3 × 1.7
36.7
6.8
3 x 218
CPV-P18/11-3S-6PDL
2008 Sep 01
977
TYPE NUMBER
Ferroxcube
P cores and accessories
P18/11/I
DATA SHEET STATUS DEFINITIONS
DATA SHEET
STATUS
PRODUCT
STATUS
DEFINITIONS
Preliminary
specification
Development
This data sheet contains preliminary data. Ferroxcube reserves the right to
make changes at any time without notice in order to improve design and
supply the best possible product.
Product specification
Production
This data sheet contains final specifications. Ferroxcube reserves the right
to make changes at any time without notice in order to improve design and
supply the best possible product.
DISCLAIMER
Life support applications  These products are not designed for use in life support appliances, devices, or systems
where malfunction of these products can reasonably be expected to result in personal injury. Ferroxcube customers
using or selling these products for use in such applications do so at their own risk and agree to fully indemnify Ferroxcube
for any damages resulting from such application.
PRODUCT STATUS DEFINITIONS
STATUS
INDICATION
DEFINITION
Prototype
These are products that have been made as development samples for the purposes of
technical evaluation only. The data for these types is provisional and is subject to
change.
Design-in
These products are recommended for new designs.
Preferred
These products are recommended for use in current designs and are available via our
sales channels.
Support
These products are not recommended for new designs and may not be available
through all of our sales channels. Customers are advised to check for availability.
2008 Sep 01
978