FERROXCUBE DATA SHEET P9/5 P cores and accessories Supersedes data of September 2004 2008 Sep 01 Ferroxcube P cores and accessories P9/5 CORE SETS Effective core parameters SYMBOL PARAMETER VALUE UNIT Σ(I/A) core factor (C1) 1.24 mm−1 Ve effective volume 126 mm3 Ie effective length 12.5 mm Ae effective area 10.1 mm2 Amin minimum area 7.9 mm2 m mass of set ≈ 0.8 g 7.5 0.25 0 2 0.2 3.9 0 0 9.3 0.3 0.2 6.5 0.25 O 2.1 0.1 0 0.3 5.4 0.3 3.6 0 1.3 0.1 0.55 max M1.4 MGC211 O 2.9 Dimensions in mm. Fig.1 P9/5 core set. Core sets for filter applications Clamping force for AL measurements, 25 ±5 N. GRADE 3D3 3H3 AL (nH) 40 ±3% µe TOTAL AIR GAP (µm) TYPE NUMBER (WITH NUT) TYPE NUMBER (WITHOUT NUT) ≈ 39 ≈ 410 P9/5-3D3-E40/N P9/5-3D3-A63/N P9/5-3D3-A63 − P9/5-3D3 P9/5-3H3-E40 P9/5-3D3-E40 63 ±3% ≈ 62 ≈ 230 630 ±25% ≈ 620 ≈0 40 ±3% ≈ 39 ≈ 430 P9/5-3H3-E40/N ≈ 62 ≈ 250 P9/5-3H3-A63/N P9/5-3H3-A63 ≈ 1080 ≈0 − P9/5-3H3 63 ±3% 1100 ±25% Core sets for general purpose transformers and power applications Clamping force for AL measurements, 10 ±5 N. AL (nH) µe 3C81 1350 ±25% ≈ 1200 ≈0 P9/5-3C81 3C91 1350 ±25% ≈ 1200 ≈0 P9/5-3C91 3F3 1100 ±25% ≈ 1080 ≈0 P9/5-3F3 GRADE 2008 Sep 01 AIR GAP (µm) 928 TYPE NUMBER Ferroxcube P cores and accessories P9/5 Core sets of high permeability grades Clamping force for AL measurements, 25 ±5 N. GRADE 3E27 AL (nH) µe AIR GAP (µm) 2300 ±25% ≈ 2020 ≈0 TYPE NUMBER P9/5-3E27 Properties of core sets under power conditions B (mT) at CORE LOSS (W) at H = 250 A/m; f = 25 kHz; T = 100 °C f = 25 kHz; ˆ = 200 mT; B T = 100 °C f = 100 kHz; ˆ = 100 mT; B T = 100 °C f = 100 kHz; ˆ = 200 mT; B T = 100 °C f = 400 kHz; ˆ = 50 mT; B T = 100 °C 3C81 ≥320 ≤ 0.035 − − − 3C91 ≥315 − 3F3 ≥315 − GRADE ≤ ≤ 0.015 Note 1. Measured at 60 °C. 2008 Sep 01 0.008(1) 929 ≤ 0.06 (1) − − ≤ 0.03 Ferroxcube P cores and accessories P9/5 INDUCTANCE ADJUSTERS General data ITEM handbook, halfpage SPECIFICATION Material of head and thread polypropylene (PP), glass fibre reinforced Maximum operating temperature 125 °C O 2.13 0.07 0 6.2 2.55 M1.4 0.5 1.5 min MGC212 Dimensions in mm. Fig.2 P9/5 inductance adjuster. Inductance adjuster selection chart GRADE 3D3 (applies to all types) TYPES FOR MEDIUM ∆L/L(1) ADJUSTMENT TYPES FOR LOW ADJUSTMENT ∆L/L(1) 40 − − ADJ-P9/P11-YELLOW 11 − 63 − − − 18 ADJ-P9/P11-BROWN Note 1. Maximum adjustment range. 2008 Sep 01 TYPES FOR HIGH ADJUSTMENT AL (nH) 930 ∆L/L(1) − 31 Ferroxcube P cores and accessories P9/5 COIL FORMERS General data for coil former CP-P9/5-1S PARAMETER SPECIFICATION Coil former material polybutyleneterephtalate (PBT), glass reinforced, flame retardant in accordance with “UL 94V-0” ; UL file number E45329 (R) Maximum operating temperature 155 °C, “IEC 60085”, class F 3.5 handbook, full pagewidth 0 0.1 0 0 4.78 0.1 7.35 0.1 1.5 4 0.1 2.7 0 0.1 0 MGC213 Dimensions in mm. Fig.3 Coil former: CP-P9/5-1S. Winding data and area product for coil former CP-P9/5-1S NUMBER OF SECTIONS WINDING AREA (mm 2) MINIMUM WINDING WIDTH (mm) AVERAGE LENGTH OF TURN (mm) AREA PRODUCT Ae x Aw (mm4) 1 3.1 2.5 18.9 31.3 2008 Sep 01 931 TYPE NUMBER CP-P9/5-1S Ferroxcube P cores and accessories P9/5 MOUNTING PARTS General data ITEM REMARKS Clamp FIGURE spring steel, tin plated 4 4 ± 0.25 handbook, halfpage 8 ± 0.25 9.75 ± 0.25 6.15 ± 0.25 4.4 ± 0.5 0.25 10 ± 0.25 1.4 ± 0.25 MGB606 Dimensions in mm. Fig.4 Clamp: CLM/TP-P9/5. 2008 Sep 01 932 TYPE NUMBER CLM/TP-P9/5 Ferroxcube P cores and accessories P9/5 DATA SHEET STATUS DEFINITIONS DATA SHEET STATUS PRODUCT STATUS DEFINITIONS Preliminary specification Development This data sheet contains preliminary data. Ferroxcube reserves the right to make changes at any time without notice in order to improve design and supply the best possible product. Product specification Production This data sheet contains final specifications. Ferroxcube reserves the right to make changes at any time without notice in order to improve design and supply the best possible product. DISCLAIMER Life support applications These products are not designed for use in life support appliances, devices, or systems where malfunction of these products can reasonably be expected to result in personal injury. Ferroxcube customers using or selling these products for use in such applications do so at their own risk and agree to fully indemnify Ferroxcube for any damages resulting from such application. PRODUCT STATUS DEFINITIONS STATUS INDICATION DEFINITION Prototype These are products that have been made as development samples for the purposes of technical evaluation only. The data for these types is provisional and is subject to change. Design-in These products are recommended for new designs. Preferred These products are recommended for use in current designs and are available via our sales channels. Support These products are not recommended for new designs and may not be available through all of our sales channels. Customers are advised to check for availability. 2008 Sep 01 933