FERROXCUBE P9-3D3-E40

FERROXCUBE
DATA SHEET
P9/5
P cores and accessories
Supersedes data of September 2004
2008 Sep 01
Ferroxcube
P cores and accessories
P9/5
CORE SETS
Effective core parameters
SYMBOL
PARAMETER
VALUE
UNIT
Σ(I/A)
core factor (C1)
1.24
mm−1
Ve
effective volume
126
mm3
Ie
effective length
12.5
mm
Ae
effective area
10.1
mm2
Amin
minimum area
7.9
mm2
m
mass of set
≈ 0.8
g
7.5
0.25
0
2
0.2
3.9
0
0
9.3
0.3
0.2
6.5 0.25
O 2.1 0.1
0
0.3
5.4 0.3
3.6 0
1.3
0.1
0.55
max
M1.4
MGC211
O 2.9
Dimensions in mm.
Fig.1 P9/5 core set.
Core sets for filter applications
Clamping force for AL measurements, 25 ±5 N.
GRADE
3D3
3H3
AL
(nH)
40 ±3%
µe
TOTAL AIR GAP
(µm)
TYPE NUMBER
(WITH NUT)
TYPE NUMBER
(WITHOUT NUT)
≈ 39
≈ 410
P9/5-3D3-E40/N
P9/5-3D3-A63/N
P9/5-3D3-A63
−
P9/5-3D3
P9/5-3H3-E40
P9/5-3D3-E40
63 ±3%
≈ 62
≈ 230
630 ±25%
≈ 620
≈0
40 ±3%
≈ 39
≈ 430
P9/5-3H3-E40/N
≈ 62
≈ 250
P9/5-3H3-A63/N
P9/5-3H3-A63
≈ 1080
≈0
−
P9/5-3H3
63 ±3%
1100 ±25%
Core sets for general purpose transformers and power applications
Clamping force for AL measurements, 10 ±5 N.
AL
(nH)
µe
3C81
1350 ±25%
≈ 1200
≈0
P9/5-3C81
3C91
1350 ±25%
≈ 1200
≈0
P9/5-3C91
3F3
1100 ±25%
≈ 1080
≈0
P9/5-3F3
GRADE
2008 Sep 01
AIR GAP
(µm)
928
TYPE NUMBER
Ferroxcube
P cores and accessories
P9/5
Core sets of high permeability grades
Clamping force for AL measurements, 25 ±5 N.
GRADE
3E27
AL
(nH)
µe
AIR GAP
(µm)
2300 ±25%
≈ 2020
≈0
TYPE NUMBER
P9/5-3E27
Properties of core sets under power conditions
B (mT) at
CORE LOSS (W) at
H = 250 A/m;
f = 25 kHz;
T = 100 °C
f = 25 kHz;
ˆ = 200 mT;
B
T = 100 °C
f = 100 kHz;
ˆ = 100 mT;
B
T = 100 °C
f = 100 kHz;
ˆ = 200 mT;
B
T = 100 °C
f = 400 kHz;
ˆ = 50 mT;
B
T = 100 °C
3C81
≥320
≤ 0.035
−
−
−
3C91
≥315
−
3F3
≥315
−
GRADE
≤
≤ 0.015
Note
1. Measured at 60 °C.
2008 Sep 01
0.008(1)
929
≤
0.06 (1)
−
−
≤ 0.03
Ferroxcube
P cores and accessories
P9/5
INDUCTANCE ADJUSTERS
General data
ITEM
handbook, halfpage
SPECIFICATION
Material of head
and thread
polypropylene (PP),
glass fibre reinforced
Maximum operating
temperature
125 °C
O 2.13
0.07
0
6.2
2.55
M1.4
0.5
1.5
min
MGC212
Dimensions in mm.
Fig.2 P9/5 inductance adjuster.
Inductance adjuster selection chart
GRADE
3D3
(applies to all types)
TYPES FOR MEDIUM
∆L/L(1)
ADJUSTMENT
TYPES FOR LOW
ADJUSTMENT
∆L/L(1)
40
−
−
ADJ-P9/P11-YELLOW
11
−
63
−
−
−
18
ADJ-P9/P11-BROWN
Note
1. Maximum adjustment range.
2008 Sep 01
TYPES FOR HIGH
ADJUSTMENT
AL
(nH)
930
∆L/L(1)
−
31
Ferroxcube
P cores and accessories
P9/5
COIL FORMERS
General data for coil former CP-P9/5-1S
PARAMETER
SPECIFICATION
Coil former material
polybutyleneterephtalate (PBT), glass reinforced, flame retardant in
accordance with “UL 94V-0” ; UL file number E45329 (R)
Maximum operating temperature
155 °C, “IEC 60085”, class F
3.5
handbook, full pagewidth
0
0.1
0
0
4.78 0.1 7.35 0.1
1.5
4
0.1
2.7 0
0.1
0
MGC213
Dimensions in mm.
Fig.3 Coil former: CP-P9/5-1S.
Winding data and area product for coil former CP-P9/5-1S
NUMBER OF
SECTIONS
WINDING
AREA
(mm 2)
MINIMUM
WINDING
WIDTH
(mm)
AVERAGE
LENGTH OF
TURN
(mm)
AREA
PRODUCT
Ae x Aw
(mm4)
1
3.1
2.5
18.9
31.3
2008 Sep 01
931
TYPE NUMBER
CP-P9/5-1S
Ferroxcube
P cores and accessories
P9/5
MOUNTING PARTS
General data
ITEM
REMARKS
Clamp
FIGURE
spring steel, tin plated
4
4
± 0.25
handbook, halfpage
8
± 0.25
9.75 ± 0.25
6.15
± 0.25
4.4 ± 0.5
0.25
10 ± 0.25
1.4
± 0.25
MGB606
Dimensions in mm.
Fig.4 Clamp: CLM/TP-P9/5.
2008 Sep 01
932
TYPE NUMBER
CLM/TP-P9/5
Ferroxcube
P cores and accessories
P9/5
DATA SHEET STATUS DEFINITIONS
DATA SHEET
STATUS
PRODUCT
STATUS
DEFINITIONS
Preliminary
specification
Development
This data sheet contains preliminary data. Ferroxcube reserves the right to
make changes at any time without notice in order to improve design and
supply the best possible product.
Product specification
Production
This data sheet contains final specifications. Ferroxcube reserves the right
to make changes at any time without notice in order to improve design and
supply the best possible product.
DISCLAIMER
Life support applications  These products are not designed for use in life support appliances, devices, or systems
where malfunction of these products can reasonably be expected to result in personal injury. Ferroxcube customers
using or selling these products for use in such applications do so at their own risk and agree to fully indemnify Ferroxcube
for any damages resulting from such application.
PRODUCT STATUS DEFINITIONS
STATUS
INDICATION
DEFINITION
Prototype
These are products that have been made as development samples for the purposes of
technical evaluation only. The data for these types is provisional and is subject to
change.
Design-in
These products are recommended for new designs.
Preferred
These products are recommended for use in current designs and are available via our
sales channels.
Support
These products are not recommended for new designs and may not be available
through all of our sales channels. Customers are advised to check for availability.
2008 Sep 01
933