FERROXCUBE RM4-3H3-A63

FERROXCUBE
DATA SHEET
RM4
RM, RM/I, RM/ILP cores and
accessories
Supersedes data of September 2004
2008 Sep 01
Ferroxcube
RM, RM/I, RM/ILP cores and accessories
RM4
CORE SETS
handbook, halfpage
Effective core parameters
SYMBOL
PARAMETER
VALUE
UNIT
Σ(I/A)
core factor (C1)
1.94
mm−1
Ve
effective volume
230
mm3
Ie
effective length
21.3
mm
Ae
effective area
11.0
mm2
Amin
minimum area
8.1
mm2
m
mass of set
≈ 1.5
g
0
9.8 0.4
M1.4
0
4.6 0.2 2.5
5.8 min
0
11 0.5
0
O 3.9 0.2
9
0.14
0.06
O 2.04 0
0.4 10.4
7 0
0.1
2
MBE082
0.4
O 7.95 0
Dimensions in mm.
Fig.1 RM4 core set.
Core sets for filter applications
Clamping force for AL measurements, 20 ±10 N.
GRADE
3D3
3H3
AL
(nH)
40 ±3%
TOTAL AIR GAP
(µm)
TYPE NUMBER
(WITH NUT)
TYPE NUMBER
(WITHOUT NUT)
≈ 62
≈ 470
RM4-3D3-E40/N
RM4-3D3-A63/N
RM4-3D3-A63
−
RM4-3D3
RM4-3D3-E40
63 ±3%
≈ 97
≈ 250
400 ±25%
≈ 616
≈0
63 ±3%
≈ 97
≈ 280
RM4-3H3-A63/N
RM4-3H3-A63
100 ±3%
≈ 154
≈ 160
RM4-3H3-A100/N
RM4-3H3-A100
≈ 247
≈ 85
RM4-3H3-A160/N
RM4-3H3-A160
≈ 1390
≈0
−
RM4-3H3
160 ±3%
900 ±25%
2008 Sep 01
µe
1164
Ferroxcube
RM, RM/I, RM/ILP cores and accessories
RM4
INDUCTANCE ADJUSTERS
General data
handbook, halfpage
PARAMETER
O 2.13
SPECIFICATION
Material of head
and thread
polypropylene (PP),
glass fibre reinforced
Maximum operating
temperature
125 °C
0.07
0
7.8
3.05
M 1.4
0.5
1.5
min
MBE079
Dimensions in mm.
Fig.2 RM4 inductance adjuster.
Inductance adjuster selection chart
(applies to all types)
∆L/L
%(1)
GRADE
AL
(nH)
3H3; 3D3
63
−
−
−
100
−
−
ADJ-RM4/RM5-RED
TYPES FOR LOW
ADJUSTMENT
TYPES FOR MEDIUM
ADJUSTMENT
−
17
TYPES FOR HIGH
ADJUSTMENT
∆L/L
%(1)
ADJ-RM4/RM5-RED
27
ADJ-RM4/RM5-BROWN
25
160
ADJ-RM4/RM5-GREEN
5
ADJ-RM4/RM5-BROWN
14
ADJ-RM4/RM5-GREY
26
250
ADJ-RM4/RM5-RED
5
ADJ-RM4/RM5-GREY
12
ADJ-RM4/RM5-BLACK
17
Note
1. Maximum adjustment range.
2008 Sep 01
∆L/L
%(1)
1165
Ferroxcube
RM, RM/I, RM/ILP cores and accessories
RM4
COIL FORMER
General data
PARAMETER
SPECIFICATION
Coil former material
polyester (UP), glass-reinforced, flame retardant in accordance with
“UL 94V-0”; UL file number E61040(M)
Pin material
copper-tin alloy (CuSn), tin (Sn) plated
Maximum operating temperature
180 °C, “IEC 60085”, class H
Resistance to soldering heat
“IEC 60068-2-20”, Part 2, Test Tb, method 1B, 350 °C, 3.5 s
Solderability
“IEC 60068-2-20”, Part 2, Test Ta, method 1
handbook, full pagewidth
0
−0.1
5.55
min.
0.45
6.85
7.62
2.54
3
4
0.8
2.54
0
−0.1
0.65
∅0.5
5
4.0 +0.15
0
0
0
∅7.9 −0.2 ∅4.9 −0.1
1.0 +0.15
0
2
4.65 min
1
6
0.44 ± 0.1
0.7
4.4
Dimensions in mm.
CBW610
Fig.2 RM4 coil former.
Winding data and area product for RM4 coil former
NUMBER
OF
SECTIONS
NUMBER
OF
PINS
PIN
POSITIONS
USED
AVERAGE
LENGTH
OF TURN
(mm)
WINDING
AREA
(mm2)
WINDING
WIDTH
(mm)
AREA
PRODUCT
Ae x Aw
(mm4)
1
6
all
20
7.4
5.55
81.4
CSV-RM4-1S-6P(1)
1
5
1, 2, 3, 5, 6
20
7.4
5.55
81.4
CSV-RM4-1S-5P(1)
2
5
1, 2, 3, 5, 6
20
7
2 x 2.55
77.0
CSV-RM4-2S-5P
Note
1. Also available with post-inserted pins.
2008 Sep 01
1166
TYPE NUMBER
Ferroxcube
RM, RM/I, RM/ILP cores and accessories
MOUNTING PARTS
RM4
2.0
handbook, halfpage
General data
1.3
ITEM
SPECIFICATION
Clamping force
≈10 N
Clip material
steel
Clip plating
silver (Ag)
Solderability
“IEC 60 068-2-20”,
Part 2, Test Ta, method 1
Type number
CLI/P-RM4/5
10.1
4
0.7
MBE080
Dimensions in mm.
Fig.3 Mounting clip for RM4.
2008 Sep 01
1167
8.5
Ferroxcube
RM, RM/I, RM/ILP cores and accessories
RM4
DATA SHEET STATUS DEFINITIONS
DATA SHEET
STATUS
PRODUCT
STATUS
DEFINITIONS
Preliminary
specification
Development
This data sheet contains preliminary data. Ferroxcube reserves the right to
make changes at any time without notice in order to improve design and
supply the best possible product.
Product specification
Production
This data sheet contains final specifications. Ferroxcube reserves the right
to make changes at any time without notice in order to improve design and
supply the best possible product.
DISCLAIMER
Life support applications  These products are not designed for use in life support appliances, devices, or systems
where malfunction of these products can reasonably be expected to result in personal injury. Ferroxcube customers
using or selling these products for use in such applications do so at their own risk and agree to fully indemnify Ferroxcube
for any damages resulting from such application.
PRODUCT STATUS DEFINITIONS
STATUS
INDICATION
DEFINITION
Prototype
These are products that have been made as development samples for the purposes of
technical evaluation only. The data for these types is provisional and is subject to
change.
Design-in
These products are recommended for new designs.
Preferred
These products are recommended for use in current designs and are available via our
sales channels.
Support
These products are not recommended for new designs and may not be available
through all of our sales channels. Customers are advised to check for availability.
2008 Sep 01