FINTEK F75373

Fintek
Feature Integration Technology Inc.
F75373
F75373S/F75373SG
Fintek Hardware Monitor IC Datasheet
Release Date: July 2007
Revision: Version 0.25P
Fintek
Feature Integration Technology Inc.
F75373
F75373 Datasheet Revision History
Version
Date
Page
Revision History
0.20P
2003 Apr.
0.21P
2003 July
0.22P
2003 Dec
Add DC spec. in the datasheet
0.23P
2004 July
Revise application circuit
0.24P
2005 July
Add part no. F75373SG(Green package) and delete version ID
0.25P
2007 July
Company readdress
Original version
9~10
Update fan speed control mechanism description
LIFE SUPPORT APPLICATIONS
These products are not designed for use in life support appliances, devices, or systems where malfunction of these
products can reasonably be expected to result in personal injury. Customers using or selling these products for use in
such applications do so at their own risk and agree to fully indemnify Fintek for any damages resulting from such
improper use or sales.
Fintek
Feature Integration Technology Inc.
F75373
Table of Contents
1
GENERAL DESCRIPTION ........................................................................................................................................................ 1
2
FEATURE ..................................................................................................................................................................................... 1
3
PIN CONFIGURATION .............................................................................................................................................................. 2
4
PIN DESCRIPTION..................................................................................................................................................................... 2
5
FUNCTIONAL DESCRIPTION ................................................................................................................................................. 4
5.1
ANALOG INPUT......................................................................................................................................................................... 4
5.2
ACCESS INTERFACE .................................................................................................................................................................. 5
5.3
TEMPERATURE MEASUREMENT MACHINE ................................................................................................................................ 6
5.3.1
Monitor Temperature from thermistor.................................................................................................................................. 6
5.3.2
Over Temperature Signal (OVT#) ........................................................................................................................................ 7
5.4
5.4.1
Fan speed count ................................................................................................................................................................... 7
5.4.2
Fan speed control................................................................................................................................................................. 8
5.4.3
Fan speed control mechanism.............................................................................................................................................. 9
5.4.4
FAN_Fault#.........................................................................................................................................................................11
5.5
SMI#...................................................................................................................................................................................... 11
5.5.1
Temperature ........................................................................................................................................................................11
5.5.2
Voltage ............................................................................................................................................................................... 12
5.5.3
Fan ..................................................................................................................................................................................... 12
5.6
6
FAN .......................................................................................................................................................................................... 7
VOLT_FAULT# (VOLTAGE FAULT SIGNAL) .......................................................................................................................... 13
REGISTER DESCRIPTION ..................................................................................................................................................... 13
6.1
CONFIGURATION REGISTER  INDEX 00H ............................................................................................................................. 13
6.2
CONFIGURATION REGISTER  INDEX 01H ............................................................................................................................. 14
6.3
CONFIGURATION REGISTER  INDEX 02H ............................................................................................................................. 14
6.4
CONFIGURATION REGISTER  INDEX 03H ............................................................................................................................. 15
6.5
SERIAL BUS ADDRESS REGISTER  INDEX 04H ..................................................................................................................... 15
6.6
VALUE RAM  INDEX 10H- 2FH ........................................................................................................................................... 16
6.7
IRQ/SMI# ENABLE REGISTER 1  INDEX 30H.................................................................................................................... 17
6.8
INTERRUPT STATUS REGISTER 1  INDEX 31H ....................................................................................................................... 18
6.9
REAL TIME STATUS REGISTER 1  INDEX 32H ....................................................................................................................... 18
6.10
IRQ/SMI# ENABLE REGISTER 2  INDEX 33H ................................................................................................................ 19
6.11
INTERRUPT STATUS REGISTER 2  INDEX 34H ................................................................................................................... 19
Fintek
Feature Integration Technology Inc.
F75373
6.12
FAN_FAULT/VOLT_FAULT/OVT ENABLE REGISTER  INDEX 35H ........................................................................... 20
6.13
REAL TIME FAULT STATUS REGISTER 1  INDEX 36H ..................................................................................................... 20
6.14
5.1 CHIPID(1) REGISTER – INDEX 5AH .............................................................................................................................. 21
6.15
CHIPID(2) REGISTER – INDEX 5BH.................................................................................................................................... 21
6.16
VENDOR ID(1) REGISTER – INDEX 5DH ........................................................................................................................... 21
6.17
VENDOR ID(2) REGISTER – INDEX 5EH............................................................................................................................ 21
6.18
RESET TIMER CONTROL REGISTER -- INDEX 60H ................................................................................................................ 21
6.19
FAN FAULT TIME REGISTER -- INDEX 61H ........................................................................................................................... 22
6.20
RESET-TIMER TIME REGISTER -- INDEX 62H ..................................................................................................................... 23
6.21
FAN STEP TIME DEFINED REGISTER -- INDEX 63H............................................................................................................. 23
6.22
VT1 OFFSET REGISTER -- INDEX 64H ............................................................................................................................... 23
6.23
VT2 OFFSET REGISTER -- INDEX 65H ............................................................................................................................... 24
6.24
RESERVED REGISTER  INDEX 66H ~ 68H (FINTEK USE ONLY) ..................................................................................... 24
6.25
PWMOUT1 RAISE DUTY-CYCLE  INDEX 69H ........................................................................................................... 24
6.26
PWMOUT2 RAISE DUTY-CYCLE  INDEX 6AH .......................................................................................................... 25
6.27
PWMOUT1 DROP DUTY-CYCLE  INDEX 6BH ........................................................................................................... 25
6.28
PWMOUT2 DROP DUTY-CYCLE  INDEX 6CH ........................................................................................................... 25
6.29
RESERVED REGISTER  INDEX 6DH ~ 6FH (FINTEK USE ONLY) .................................................................................... 25
6.30
FAN1 FULL SPEED COUNT REGISTER 0  INDEX 70H........................................................................................................ 25
6.31
FAN1 FULL SPEED COUNT REGISTER 1 INDEX71H .......................................................................................................... 26
6.32
FAN1 EXPECT TIMEOUT SPEED REGISTER  INDEX 72H .................................................................................................... 26
6.33
FAN1 EXPECT TIMEOUT SPEED REGISTER  INDEX 73H .................................................................................................... 26
6.34
FAN1 EXPECT COUNT REGISTER-- INDEX 74H .................................................................................................................... 27
6.35
FAN1 EXPECT COUNT REGISTER-- INDEX 75H .................................................................................................................... 27
6.36
FAN1 PWM_DUTY -- INDEX 76H...................................................................................................................................... 27
6.37
FAN2 FULL SPEED REGISTER 0  INDEX 80H .................................................................................................................... 27
6.38
FAN2 FULL SPEED REGISTER 1 INDEX 81H ..................................................................................................................... 28
6.39
FAN2 EXPECT TIMEOUT SPEED REGISTER  INDEX 82H .................................................................................................... 28
6.40
FAN2 EXPECT TIMEOUT SPEED REGISTER  INDEX 83H .................................................................................................... 28
6.41
FAN2 EXPECT COUNT REGISTER-- INDEX 84H .................................................................................................................... 28
6.42
FAN2 EXPECT COUNT REGISTER-- INDEX 85H .................................................................................................................... 29
6.43
PWM_DUTY -- INDEX 86H ................................................................................................................................................ 29
6.44
GPIOX OUTPUT CONTROL REGISTER – INDEX 90H............................................................................................................. 29
6.45
GPIOX OUTPUT DATA REGISTER – INDEX 91H ................................................................................................................... 30
6.46
GPIO1X INPUT STATUS REGISTER – INDEX 92H.................................................................................................................. 30
6.47
VT1 BOUNDARY 1 TEMPERATURE – INDEX A0H ........................................................................................................ 30
Fintek
Feature Integration Technology Inc.
F75373
7
6.48
VT1 BOUNDARY 2 TEMPERATURE – INDEX A1H ........................................................................................................ 31
6.49
VT1 BOUNDARY 3 TEMPERATURE – INDEX A2H ........................................................................................................ 31
6.50
VT1 BOUNDARY 4 TEMPERATURE – INDEX A3H ........................................................................................................ 31
6.51
FAN1 SEGMENT 1 SPEED COUNT (MSB) – INDEX A4H ............................................................................................. 32
6.52
FAN1 SEGMENT 1 SPEED COUNT (LSB) – INDEX A5H .............................................................................................. 32
6.53
FAN1 SEGMENT 2 SPEED COUNT (MSB) – INDEX A6H ............................................................................................. 32
6.54
FAN1 SEGMENT 2 SPEED COUNT (LSB) – INDEX A7H .............................................................................................. 32
6.55
FAN1 SEGMENT 3 SPEED COUNT (MSB) – INDEX A8H ............................................................................................. 33
6.56
FAN1 SEGMENT 3 SPEED COUNT (LSB) – INDEX A9H .............................................................................................. 33
6.57
FAN1 SEGMENT 4 SPEED COUNT (MSB) – INDEX AAH ............................................................................................ 33
6.58
FAN1 SEGMENT 4 SPEED COUNT (LSB) – INDEX ABH.............................................................................................. 34
6.59
FAN1 SEGMENT 5 SPEED COUNT (MSB) – INDEX ACH ............................................................................................ 34
6.60
FAN1 SEGMENT 5 SPEED COUNT (LSB) – INDEX ADH ............................................................................................. 34
6.61
VT2 BOUNDARY 1 TEMPERATURE – INDEX B0H ........................................................................................................ 34
6.62
VT2 BOUNDARY 2 TEMPERATURE – INDEX B1H ........................................................................................................ 35
6.63
VT2 BOUNDARY 3 TEMPERATURE – INDEX B2H ........................................................................................................ 35
6.64
VT2 BOUNDARY 4 TEMPERATURE – INDEX B3H ........................................................................................................ 36
6.65
FAN2 SEGMENT 1 SPEED COUNT (MSB) – INDEX B4H ............................................................................................. 36
6.66
FAN2 SEGMENT 1 SPEED COUNT (LSB) – INDEX B5H .............................................................................................. 36
6.67
FAN2 SEGMENT 2 SPEED COUNT (MSB) – INDEX B6H ............................................................................................. 36
6.68
FAN2 SEGMENT 2 SPEED COUNT (LSB) – INDEX B7H .............................................................................................. 37
6.69
FAN2 SEGMENT 3 SPEED COUNT (MSB) – INDEX B8H ............................................................................................. 37
6.70
FAN2 SEGMENT 3 SPEED COUNT (LSB) – INDEX B9H ................................................................................................ 37
6.71
FAN2 SEGMENT 4 SPEED COUNT (MSB) – INDEX BAH .............................................................................................. 38
6.72
FAN2 SEGMENT 4 SPEED COUNT (LSB) – INDEX BBH ............................................................................................... 38
6.73
FAN2 SEGMENT 5 SPEED COUNT (MSB) – INDEX BCH .............................................................................................. 38
6.74
FAN2 SEGMENT 5 SPEED COUNT (LSB) – INDEX BDH ............................................................................................... 38
6.75
RESERVED REGISTER – INDEX F0H ~ FFH (FINTEK USE ONLY) .......................................................................................... 39
ELECTRON CHARACTERISTIC .......................................................................................................................................... 39
7.1
ABSOLUTE MAXIMUM RATINGS ............................................................................................................................................. 39
7.2
DC CHARACTERISTICS ........................................................................................................................................................... 40
7.3
AC CHARACTERISTICS ........................................................................................................................................................... 41
8
ORDERING INFORMATION .................................................................................................................................................. 42
9
ACKAGE DIMENSIONS (16SOP 150MIL) ............................................................................................................................ 42
Fintek
Feature Integration Technology Inc.
F75373
1 General Description
F75373S is a system hardware monitoring and automatic fan speed controlling IC specific designed for
graphic cards etc.. F75373S can monitor several critical hardware parameters of the system, including
voltages, temperatures and fan speeds which are very important for the system to work stably and properly.
An 8-bit analog-to-digital converter (ADC) was built inside F75373S. The chip can monitor up to 4 analog
voltage inputs, 2 fan tachometer inputs and 2 remote temperature sensors. The remote temperature sensor
is suggested to be performed by thermistor. The F75373S can provide automatic fan speed control so that
the system can operate at the minimum acoustic noise. Also the users can set up the upper and lower limits
(alarm thresholds) of all monitored parameters and this chip can also issue warning messages for system
protection when there is something wrong with monitored items.
Through the BIOS or application software, the users can read all the monitored parameters of system all the
time. And a pop-up warning can be also activated when the monitored item was out of the proper/pre-setting
range. The application software could be Fintek's application software MyGuardTM, or IntelTM LDCM
(LanDesk Client Management), or other management application software. The F75373S is in the package
of 150mil 16-pin SOP and powered by 3.3V.
2 Feature
z
4 voltage inputs
-- typical for Vcore, VDDQ, and VCC3V etc
z
Monitor up to 2 remote temperature sensor from remote thermistor
z
Up to 2 fan speed monitoring input and 2 automatic fan speed control
-- 3 flexible fan control mode: Manual mode, Speed mode and Temperature mode.
z
Programmable limited and setting points(alert threshold) for all monitored items
z
Issue FAN_FAULT# or VOLT_FAULT# or OVT# or SMI# signal to activate system protection
z
Up to 4 general purpose I/O support
z
2-wire SMBus interface
z
VCC3V operation and 16SOP package(150mil)
Noted: Patented TW207103 TW207104 TW220442 US6788131 B1
1
V0.25P
Fintek
Feature Integration Technology Inc.
F75373
3 Pin Configuration
FANIN1
FANIN2/GPIO0
1
2
16
15
VCC
VT1
PWMOUT1/ADDR_TRAP
3
VT2
PWMOUT2/GPIO1
FAN_FAULT#/SMI#/GPIO2
4
5
14
13
VOLT_FAULT#/OVT#GPIO3
SCLK
6
7
11
10
VIN2
VIN3
8
9
GND
SDATA
12
VREF
VIN1
4 Pin Description
O8
- TTL level output pin with 8 mA source-sink capability
INts/OD12 - TTL level bi-directional pin, can select to O.D or OUT by register, with 12mA source-sink
capability
I/OD8
- TTL level bi-directional pin, Open-drain outpu with 8 mA sink capability
I/OD16
- TTL level bi-directional pin, Open-drain outpu with 16 mA sink capability
AOUT
- Output pin(Analog)
OD16
- Open-drain output pin with 16 mA sink capability
INt
- TTL level input pin
INts
- TTL level input pin and schmitt trigger
INtsd100k
- TTL level input pin and schmitt trigger with internal pull down 100K ohm
AIN
- Input pin(Analog)
P
‹
- Power
Power Pin
Pin No.
Pin Name
Type
Description
16
VCC
P
3.3V power supply voltage input
9
GND
P
GND
2
V0.25P
Fintek
Feature Integration Technology Inc.
F75373
‹
Monitoring Items and Fan Speed Control
Pin No.
Pin Name
Type
Description
1
FANIN1
INt
0V to +3.3V amplitude fan tachometer input.
2
GPIO0
INts/OD8
(Default) General purpose I/O pin. Default Open drain
FANIN2
INt
0V to +3.3V amplitude fan tachometer input.
PWMOUT1
O12
Fan speed control pin.
ADDR_TRAP
INtsd100k
Address power on trapping pin. Internal pull down100k ohm
GPIO1
INts/OD12
(Default) General purpose I/O pin. Default Open drain
PWMOUT2
O12
Fan speed control pin.
10
VIN3
AIN
0V to 2.048V FSR Analog Inputs
11
VIN2
AIN
0V to 2.048V FSR Analog Inputs
12
VIN1
AIN
0V to 2.048V FSR Analog Inputs
14
VT2
AIN
Thermistor 2 terminal input
15
VT1
AIN
Thermistor 1 terminal input.
3
4
‹
Alert Signals and Others
Pin No.
Pin Name
Type
Description
5
GPIO2
INts/OD16
(Default) General purpose I/O function. Default pure open drain
SMI#
OD16
System management interrupt (Pure Open Drain)
FAN_FAULT#
OD16
This pin will be a logic LOW when the fan speed is abnormal.
GPIO3
INts/OD8
(Default) General purpose I/O function. Default Open drain
OVT#
OD8
Active-Low output. This pin will be a logic LOW when the temperature
6
exceeds its limit.
VOLT_FAULT#
OD8
Active-Low output. This pin will be a logic LOW when the voltage exceeds
its limit.
13
‹
VREF
AOUT
Reference Voltage. 2.304v
Serial Bus Control Pin
Pin No.
Pin Name
Type
Description
8
SDATA
INts/OD12
Serial Bus data.
7
SCLK
INt s
Serial Bus clock.
3
V0.25P
Fintek
Feature Integration Technology Inc.
F75373
5 Functional Description
F75373S is a system hardware monitoring and automatic fan speed controlling IC specific designed for
graphic cards. The chip can monitor up to 4 analog voltage inputs, 2 fan tachometer inputs and 2 remote
temperature sensors. The remote temperature sensor is suggested to be performed by thermistor. The
F75373S can provide automatic fan speed control so that the system can operate at the minimum acoustic
noise. Also the users can set up the upper and lower limits (alarm thresholds) of all monitored parameters and
this chip can also issue warning messages for system protection when there is something wrong with
monitored items.
5.1
Analog Input
For the 8-bit ADC has the 7.8125mv LSB, the maximum input voltage of the analog pin is 2V. Therefore the voltage under 2V
(ex:1.5V) can directly connected to these analog inputs. The voltage higher than 2V should be reduced by a factor with external
resistors so as to obtain the input range. Only 3VCC is an exception for it is main power of the F75373S. Therefore 3VCC can
directly connect to this chip and need no external resistors. There are two functions in this pin with 3.3V. The first function is to
supply internal analog power of the F75373S and the second function is that this voltage with 3.3V is connected to internal serial
resistors to monitor the +3.3V voltage. The internal serial resistors are two 50K ohm, so that the internal reduced voltage is half
+3.3V.
There are four voltage inputs in the F75373S and the voltage divided formula is shown as follows:
VIN = V+3.3V ×
R2
R1 + R2
where V+3.3V is the analog input voltage, for example.
If we choose R1=2K, R2=1K, the exact input voltage for V+3.3V will be 1.1V, which is within the tolerance.
As for application circuit, it can be refer to the figure shown as follows.
4
V0.25P
Fintek
Feature Integration Technology Inc.
F75373
3VCC
Voltage Inputs
50K
(directly connect to the chip)
VIN3.3
VIN (Lower than 2.048V)
50K
(directly connect to the chip)
VIN1(Max2.048V)
VIN(Higher than 2.048V)
R1
R2
8-bit ADC
with
7.8125mV LSB
R
10K, 1%
VREF
Typical Thermister
Connection
Pin 13
Pin 14/15
RTHM
10K, 25 C
Figure 5-3
5.2 Access Interface
The F75373S provides one serial access interface, Serial Bus, to read/write internal registers. The address of
Serial Bus is configurable by using power-on trapping. The pin 3 (PWMOUT1/ADDR_TRAP) is multi-function pin.
During power-on, this pin serves as input detection of logic high or logic low. This pin is default pull-down resistor with
100K ohms mapping the Serial Bus address 0x5A (0101_1010). Another Serial Bus address 0x5C (0101_1100) is
set when external pull-up resistor with 10K ohms is connected in this pin.
(a) Serial bus write to internal address register followed by the data byte
0
7
8
0
7
8
SCL
SDA
0
Start By
Master
1
0
1
1
0
1
R/W
D7
D6
Ack
by
373S
Frame 1
Serial Bus Address Byte
D5
D4
D3
D2
D1
D0
Ack
by
373S
Frame 2
Internal Index Register Byte
0
7
8
SCL (Continued)
SDA (Continued)
D7
D6
D5
D4
D3
D2
D1
D0
Stop
by
Master
Frame 3
Data Byte
Figure 1. Serial Bus Write to Internal Address Register followed by the Data Byte
5
V0.25P
Fintek
Feature Integration Technology Inc.
F75373
(b) Serial bus read form internal address register followed by the data byte
0
SCL
SDA
0
7
1
Start By
Master
0
1
1
0
1
8
0
R/W
D7
7
D6
ack
by
373S
Frame 1
Serial Bus Address Byte
D5
D4
D3
D2
D1
D0
ack
by
373S
Frame 2
Internal Index Register Byte
0
1
2
3
4
5
6
7
0
1
0
1
1
0
1
R/W
8
8
0
1
2
3
4
5
6
7
D7
D6
D5
D4
D3
D2
D1
D0
8
SCL(Continued)
SDA(Continued)
ack
by
373S
Frame 3
Serial Bus Byte
Frame 4
Data Byte
ack Stop by
Master
by
373S
Figure 2. Serial Bus read from Internal Address Register followed by the Data Byte
5.3
Temperature Measurement Machine
The temperature data format is 8-bit two-complement for thermal sensor. The 8-bit temperature data can be obtained by reading
through register. The format of the temperature data is show in Table 4-1.
Temperature
8-Bit Digital Output
8-Bit Binary
8-Bit Hex
+125°C
0111,1101
7Dh
+25°C
0001,1001
19h
+2°C
0000,0010
02h
+1°C
0000,0001
01h
+0°C
0000,0000
00h
-1°C
1111,1111
FFh
-2°C
1111,1110
FEh
-25°C
1110,0111
E7h
-50°C
1100,1110
CEh
Table 4-1.
5.3.1 Monitor Temperature from thermistor
The F75373S can connect two thermistors to measure environment temperature or remote temperature. The specification of
thermistor should be considered to (1) β value is 3435K (2) resistor value is 10K ohm at 25°C. In the Figure 4-3, the themistor is
6
V0.25P
Fintek
Feature Integration Technology Inc.
F75373
connected by a serial resistor with 10K Ohm, then connect to VREF (pin13).
5.3.2 Over Temperature Signal (OVT#)
The F75373S can provide two external thermal sensors to detect temperature. When monitored temperature exceeds the
over-temperature threshold value, OVT# will be asserted until the temperature goes below the hysteresis temperature.
To
THYST
OVT#
Figure 5-4
5.4 Fan
5.4.1 Fan speed count
Inputs are provided by the signals from fans equipped with tachometer outputs. The level of these signals should be set to TTL
level, and maximum input voltage cannot be over VCC. If the input signals from the tachometer outputs are over the VCC, the
external trimming circuit should be added to reduce the voltage to obtain the input specification. The normal circuit and
trimming circuits are shown as follows:
+12V
+12V
Pull-up resister
4.7K Ohms
Pull-up resister < 1K
or totem-pole output
+12V
FAN Out
22K~30K
Fan Input
+12V
FANIN 1
GND
10K
> 1K
FAN Out
Fan Input
FANIN 1
GND
3.3V Zener
F75373S
FAN
Connector
Figure 5-5 Fan with Tach Pull-Up to +12V, or Totern-Pole
Output and Register Attenuator
7
F75373S
Figure 5-6 Fan with Tach Pull-Up to +12V, or
Totem-Pole Putput and Zener Clamp
V0.25P
Fintek
Feature Integration Technology Inc.
F75373
+5V
+5V
Pull-up resister
4.7K Ohms
Pull-up resister < 1K
or totem-pole output
+5V
1K~2.7K
Fan Input
FAN Out
+5V
FANIN1
> 1K
FAN Out
GND
Fan Input
FANIN1
GND
10K
3.3V Zener
F75373S
FAN
Connector
F75373S
.Figure 5-8 Fan with Tach Pull-Up to +5V, or
Totem-Pole Putput and Zener Clamp
Figure 5-7. Fan with Tach Pull-Up to +5V, or Totern-Pole
Output and Register Attenuator
Determine the fan counter according to:
Count =
1.5 × 10 6
RPM
In other words, the fan speed counter has been read from register, the fan speed can be evaluated by the following equation. As
for fan, it would be best to use 2 pulses tachmeter output per round.
RPM =
5.4.2
1.5 × 10 6
Count
Fan speed control
The F75373S provides 2 fan PWM speed control. The duty cycle of PWM can be programmed by a 8-bit register which are
defined in the CR76h and CR86h. The default duty cycle is set to 100%, that is, the default 8-bit registers is set to FFh. The
expression of duty can be represented as follows.
Duty_cycle(%) =
Programmed 8 - bit Register Value
× 100%
255
+5V
+12V
R1
R1
R2
R2
PNP Transistor
D
G
PWM Clock Input
PNP Transistor
D
G
NMOS
S
PWM Clock Input
NMOS
S
+
C
+
C
FAN
-
FAN
-
Figure 5-9
Figure 5-10
8
V0.25P
Fintek
Feature Integration Technology Inc.
F75373
5.4.3
Fan speed control mechanism
There are 3 modes to control fan speed and they are manual, fan speed mode and temperature mode. For manual
mode, it generally acts as PWM fan speed control. As for speed mode and temperature mode, they are more
intelligent fan speed control and described as below:
5.4.3.1 Fan Speed mode
Fan speed mode is an intelligent method according to expected fan speed pre-setting by BIOS. In the beginning, fan speed
will operate at full speed and the F75373S will get the full speed count value. Then fan speed slows down to rotate
at about 72.5% (8/11) of full speed. After that, the fan speed will automatically rotate according to the expected fan
speed setting by BIOS. The register CR74h and CR75h are used for this mode.
5.4.3.2 Temperature mode
At this mode, F75373S provides the clever system to automatically control fan speed related to temperature of
GPU or the system. The F75373S can provide four temperature boundaries and five intervals, and each interval
has its related fan speed count. All these values should be set by BIOS first. Take figure 5-11 as example. When
temperature setting value is 45,55,65, and 75°C. There are five intervals and each interval is 10°C. The related
desired fan speed counts for each interval are 0500h, 0400h, 0300h, 0200h, 0100h. When the temperature is
within 55~65°C, the fan speed count 300h will be load into FAN EXPECT COUNTregisters(CR74h~CR75h,
CR84h~CR85h). Then, F75373S will adjust PWMOUT duty-cycle to make fan speed match the expected value. It
can be said that the fan will be turned on with a specific speed set by BIOS and automatically controlled with the
temperature varying. The F75373S will take charge of all the fan speed control and need no software support.
Desired Counts
0100h
75 Degree C
0200h
65 Degree C
0300h
55 Degree C
0400h
45 Degree C
0500h
Figure 5-11
9
V0.25P
Fintek
Feature Integration Technology Inc.
F75373
5.4.3.3 PWMOUT Duty-cycle operating process
In both “FAN SPEED” and “TEMPERATURE” modes, F75373S adjust PWMOUT duty-cycle according to current
fan count and expected fan count. It will operate as follows:
(1). When expected count is FFFFh, PWMOUT duty-cycle will be set to 00h to turn off fan.
(2). When expected count is 0000h, PWMOUT duty-cycle will be set to FFh to turn on fan with full speed.
(3). If both (1) and (2) are not true and KEEP_DROP_DUTY(see INDEX 60h) is set to 0,
(a). When PWMOUT duty-cycle decrease to DROP_DUTY(≠ 00h), obviously the duty-cycle will be 00h next,
F75373S will keep duty-cycle at 00h 3 seconds1. After that, F75373S starts to compare current fan count and
expected count in order to increase or decrease its duty-cycle. This ensures that if there is any glitch during the 3
seconds1 period, F75373S will ignore it.
(b). When PWMOUT duty-cycle increase from 00h to RAISE_DUTY(≠ 00h), F75373S also will keep duty-cycle
at RAISE-DUTY 3 seconds1. After that, F75373S starts to compare current fan count and expected count in order
to increase or decrease its duty-cycle. This ensures that if there is any glitch during the 3 seconds1 period,
F75373S will ignore it.
Note 1: The period can be programmed at INDEX 6Eh.
10
V0.25P
Fintek
Feature Integration Technology Inc.
F75373
5.4.4 FAN_Fault#
Fan_Fault will be aserted when the fan speed doesn’t meet the expected fan speed within a programmable period(default is 3
minutes) . There are two conditions may cause the FAN_FAULT#.
(1). When PWM_Duty reaches FFh, the fan speed count can’t reach the fan expected count in time. (Figure 5-12)
(2). When PWM_Duty reaches 00h, if the fan speed count can’t reach the fan expected count in time.(Figure 5-13)
3 min(default)
Current Fan Count
Expected Fan Count
100%
Duty-cycle
Fan_Fault#
Figure 5-12
3 min(default)
Expected Fan Count
Current Fan Count
Duty-cycle 0%
Fan_Fault#
Figure 5-13
5.5 SMI#
5.5.1 Temperature
SMI# interrupt for temperature is shown as figure 5-13. Temperature exceeding high limit or going below hystersis will
cause an interrupt if the previous interrupt has been reset by writing “1” all the interrupt Status Register.
11
V0.25P
Fintek
Feature Integration Technology Inc.
F75373
To
THYST
SMI#
(pulse mode)
*
*
*
(level mode
active low)
*
*Interrupt Reset when Interrupt Status Registers are written 1
Figure 5-13
5.5.2 Voltage
SMI# interrupt for voltage is shown as figure 5-14. Voltage exceeding or going below high limit will cause an interrupt if the
previous interrupt has been reset by writing “1” all the interrupt Status Register. Voltage exceeding or going below low limit will
result in the same condition as voltage exceeding or going below high limit.
5.5.3
Fan
SMI# interrupt for fan is shown as figure 5-15 . SMI# will be asserted when the fan speed count exceeds or goes below the fan
limit (Value RAM 2Ch~2Dh, 2Eh~2Fh).
Voltage High limit
Fan Count limit
Voltage Low limit
Fan Count limit
SMI#
SMI#
(pulse mode)
(level mode)
*
*
*
*
(pulse mode)
*
*
*
(level mode)
*
*
*
*
*
*Interrupt Reset when Interrupt Status Registers are written 1
Voltage SMI# Mode
FAN SMI# Mode
Figure 5-14
Figure 5-15
12
V0.25P
Fintek
Feature Integration Technology Inc.
F75373
5.6 VOLT_FAULT# (Voltage Fault Signal)
When voltage leaps from the security range setting by BIOS, the warning signal VOLT_FAULT# will be activated. Shown in figure
5-16
High limit
Low limit
VOLT_FAULT#
Figure 5-16
6 Register Description
6.1
Configuration Register  Index 00h
Power on default <7:0> = 01h
Bit
7
Name
INIT
Attribute
R/W
Description
Set one restores power on default value to all registers except the
Serial Bus Address register. This bit clears itself since the power on
default is zero.
6
5-1
0
SOFT_PWDN
R/W
Set this bit to 1 will power down A/D converter circuit. Default is 0
Reserved
RO
Read back will be 0
START
R/W
A one enables startup of monitoring operations; a zero puts the part
in standby mode.
13
V0.25P
Fintek
Feature Integration Technology Inc.
F75373
6.2
Configuration Register  Index 01h
Power on default <7:0> = 00h
Bit
Name
Attribute
Description
7-2
Reserved
RO
Read back will be 0
1
PIN4_MODE
R/W
Pin 4 mode select, set this bit to 1 will enable PWMOUT2 output, else
if set this bit to 0, pin 4 will be enable the GPIO1 function.(default)
This mode is trappable: When PIN3 trapped to high at power-on,
PIN4 is set to PWMOUT2. When PIN3 trapped to low at power-on,
PIN4 is set to GPIO1.
0
PIN2_MODE
R/W
Pin 2 mode select, set this bit to 1 will enable FANIN2 input, if set this
bit to 0 pin 2 will be enable the GPIO0 function.(default).
This mode is trappable: When PIN3 trapped to high at power-on,
PIN2 is set to FANIN2. When PIN3 trapped to low at power-on, PIN2
is set to GPIO0.
6.3
Configuration Register  Index 02h
Power on default <7:0> = 00h
Bit
Name
7-6
PIN5_MODE
Attribute
R/W
Description
00: pin5 function is GPIO2
01: pin5 is used as SMI
10: pin5 is used as Fan fault function
11: LED out(1Hz/0.5Hz select by bit2)
5
SMI_MODE
R/W
If set to 0, SMI will be level mode else if this bit set to 1, SMI will be
pulse mode.
4
SMI_LEVEL
R/W
When set this bit to 0 SMI is low active (default). if set to 1 SMI is high
active
3
Reserved
R/W
Reserved register
2
LED_FREQ
R/W
When set this bit to 1 fan fault LED output frequency will be 0.5HZ,
else is 1Hz(default)
1
F_FAULT_MOD
E
R/W
When set this bit to 0 the fan fault will be level mod, else if set to 1 the fan
fault will indicate by LED function(1Hz or 0.5Hz) the LED frequency can
set by REG02H bit2
14
V0.25P
Fintek
Feature Integration Technology Inc.
F75373
0
F_FAULT_LEVE
R/W
L
6.4
When set this bit to 0 fan fault is low active (default). if set to 1 fan
fault is high active
Configuration Register  Index 03h
Power on default <7:0> = 00h
Bit
7
Name
PIN6_MODE
Attribute
R/W
Description
00: pin6 function is GPIO3
01: pin6 is used as OVT
10: pin6 is used as Voltage fault function
11: Reserved
5
OVT_LEVEL
R/W
When set this bit to 0 OVT is low active (default), else if set to 1 OVT
is high active
3-4
OVT_QUEUE
R/W
OVT queue is use to filter the temperature noise, it define the times of
the event when OVT is asserted.
00: 1 times
01: 3 times
10: 5 times
11: 7 times
2
V_FAULT_LEVE
R/W
L
1-0
Voltage fault level. When set this bit to 0 voltage fault is low active
(default). if set to 1 fan fault is high active
V_FAULT_QUE
R/W
UE
Voltage fault queue. It is used to filter the voltage noise, the follow
define the times of the event when VOLT_FAULT is asserted.
00: 1 times
01: 3 times
10: 5 times
11: 7 times
6.5
Serial Bus Address Register  Index 04h
Power on default: 5Ah or 5Ch.
Bit
Name
Attribute
Description
15
V0.25P
Fintek
Feature Integration Technology Inc.
F75373
7-0
SERIAL_ADDR
RO
Serial Bus address. Power on default value depends on the status of
pin3(PWMOUT1/ADDR_TRAP) at the moment of power on. If the pin
status is 1, the value is 5Ch, otherwise is 5Ah.
To read or write registers of this chip, the serial address must match
this value.
This register can be written by a sequence value to this register :
A9h, C3h, XXh, in which XXh will be the value being written to this
register; this is to protect the register from being written by accident.
6.6
Value RAM  Index 10h- 2Fh
Address 10-3F
Attribute
Description
10h
RO
VCC reading. The unit of reading is 7.8125mV.
11h
RO
V1 reading. The unit of reading is 7.8125mV.
12h
RO
V2 reading. The unit of reading is 7.8125mV.
13h
RO
V3 reading. The unit of reading is 7.8125mV.
14h
RO
Temperature 1 reading. The unit of reading is 1ºC.
15h
RO
Temperature 2 reading. The unit of reading is 1ºC.
16h
RO
FAN1 count reading (MSB)
17h
RO
FAN1 count reading (LSB)
18h
RO
FAN2 count reading (MSB)
19h
RO
FAN2 count reading (LSB)
1Ah~1Eh
Reserved
20h
R/W
VCC High Limit. The unit is 7.8125mV.
21h
R/W
VCC Low Limit. The unit is 7.8125mV.
22h
R/W
V1 High Limit. The unit is 7.8125mV.
23h
R/W
V1 Low Limit. The unit is 7.8125mV.
24h
R/W
V2 High Limit. The unit is 7.8125mV.
25h
R/W
V2 Low Limit. The unit is 7.8125mV.
26h
R/W
V3 High Limit. The unit is 7.8125mV.
27h
R/W
V3 Low Limit. The unit is 7.8125mV.
28h
R/W
Temperature sensor 1 High Limit. The unit is 1ºC.
29h
R/W
Temperature sensor 1 Hysteresis Limit. The unit is 1ºC.
2A h
R/W
Temperature sensor 2 High Limit. The unit is 1ºC.
16
V0.25P
Fintek
Feature Integration Technology Inc.
F75373
2Bh
R/W
Temperature sensor 2 Hysteresis Limit. The unit is 1ºC.
2Ch
R/W
FAN1 Fan Count Limit
Note: It is the number of counts of the internal clock for the Low Limit
of the fan speed.
2Dh
R/W
FAN1 Fan Count Limit
Note: It is the number of counts of the internal clock for the Low Limit
of the fan speed.
2Eh
R/W
FAN2 Fan Count Limit
Note: It is the number of counts of the internal clock for the Low Limit
of the fan speed.
2Fh
R/W
FAN2 Fan Count Limit
Note: It is the number of counts of the internal clock for the Low Limit
of the fan speed.
Setting all ones to the high limits for voltages and fans (0111 1111 binary for temperature) means interrupts will never
be generated except the case when voltages go below the low limits.
6.7
IRQ/SMI# ENABLE Register 1  Index 30h
Power on default: 00h
Bit
7
Name
EN_FAN2_SMI
Attribute
R/W
Description
A one enables the corresponding interrupt status bit for SMI#
interrupt
6
EN_FAN1_SMI
R/W
A one enables the corresponding interrupt status bit for SMI#
interrupt.
5
EN_VT2_SMI
R/W
A one enables the corresponding interrupt status bit for SMI#
interrupt.
4
EN_VT1_SMI
R/W
A one enables the corresponding interrupt status bit for SMI#
interrupt.
3
EN_V3_SMI
R/W
A one enables the corresponding interrupt status bit for SMI#
interrupt.
2
EN_V2_SMI
R/W
A one enables the corresponding interrupt status bit for SMI#
interrupt.
1
EN_V1_SMI
R/W
A one enables the corresponding interrupt status bit for SMI#
interrupt.
0
EN_VCC_SMI
R/W
A one enables the corresponding interrupt status bit for SMI#
17
V0.25P
Fintek
Feature Integration Technology Inc.
F75373
interrupt.
6.8
Interrupt Status Register 1  Index 31h
Power on default: 00h
Bit
7
Name
FAN2_STS
Attribute
R/W
Description
A one indicates fan2 count limit has been exceeded. Write 1 to clear
this bit, write 0 will be ignored.
6
FAN1_STS
R/W
A one indicates fan1 count limit has been exceeded. Write 1 to clear
this bit, write 0 will be ignored.
5
VT2_STS
R/W
A one indicates a high limit of VT2 has been exceeded from
temperature sensor. Write 1 to clear this bit, write 0 will be ignored.
4
VT1_STS
R/W
A one indicates a high limit of VT1 has been exceeded from
temperature sensor. Write 1 to clear this bit, write 0 will be ignored.
3
V3_STS
R/W
A one indicates a high or low limit of VIN3 has been exceeded. Write
1 to clear this bit, write 0 will be ignored.
2
V2_STS
R/W
A one indicates a high or low limit of VIN2 has been exceeded. Write
1 to clear this bit, write 0 will be ignored.
1
V1_STS
R/W
A one indicates a high or low limit of VIN1 has been exceeded. Write
1 to clear this bit, write 0 will be ignored.
0
VCC_STS
R/W
A one indicates a high or low limit of VCC has been exceeded. Write
1 to clear this bit, write 0 will be ignored.
6.9
Real Time Status Register 1  Index 32h
Power on default: 00h
Bit
Name
7
FAN2EXC
Attribute
R/W
Description
A one indicates fan2 count limit has been exceeded. A zero indicates
fan2 count is in the safe region.
6
FAN1EXC
R/W
A one indicates fan1 count limit has been exceeded. A zero indicates
fan1 count is in the safe region.
5
VT2EXC
R/W
A one indicates a high limit of VT2 has been exceeded. A zero
indicates VT2 is below the hysteresis limit.
18
V0.25P
Fintek
Feature Integration Technology Inc.
F75373
4
VT1EXC
R/W
A one indicates a high limit of VT1 has been exceeded. A zero
indicates VT1 is below the hysteresis limit.
3
V3EXC
R/W
A one indicates a high or low limit of VIN3 has been exceeded. A zero
indicates VIN3 is in the safe region.
2
V2EXC
R/W
A one indicates a high or low limit of VIN2 has been exceeded. . A
zero indicates VIN2 is in the safe region.
1
V1EXC
R/W
A one indicates a high or low limit of VIN1 has been exceeded. . A
zero indicates VIN1 is in the safe region.
0
VCCEXC
R/W
A one indicates a high or low limit of VCC has been exceeded. . A
zero indicates VCC is in the safe region.
6.10 IRQ/SMI# ENABLE Register 2  Index 33h
Power on default: 00h
Bit
Name
7-2
Reserved
RO
EN_TARF2_SMI
R/W
1
Attribute
Description
Target fan2 SMI enable bit. A zero disables the corresponding
interrupt status bit for SMI# interrupt
0
EN_TARF1_SMI
R/W
Target fan1 SMI enable bit. A zero disables the corresponding
interrupt status bit for SMI# interrupt
6.11 Interrupt Status Register 2  Index 34h
Power on default: 00h
Bit
Name
7-2
Reserved
1
STS_TAR_FAN2
Attribute
R/W
Description
A one indicates fan2 reading count is over then fan2 expect count,
and the PWMOUT2 duty cycle is full more then the FAN FAULT
TIME. Write 1 to clear this bit, write 0 will be ignored.
0
STS_TAR_FAN1
R/W
A one indicates fan1 reading count is over then fan1 expect count,
and the PWMOUT1 duty cycle is full more then the FAN FAULT
TIME. Write 1 to clear this bit, write 0 will be ignored.
19
V0.25P
Fintek
Feature Integration Technology Inc.
F75373
6.12 FAN_FAULT/VOLT_FAULT/OVT ENABLE Register  Index 35h
Power on default: 00h
Bit
7
Name
EN_F2_FAULT
Attribute
R/W
Description
A one enables the fan2 fault status to be indicated in pin
FAN_FUALT.
6
EN_ F1_FAULT
R/W
A one enables the fan1 fault status to be indicated in pin
FAN_FUALT.
5
EN_T2_OVT
R/W
A one enables the VT2 fault status to be indicated in pin OVT.
4
EN_T1_OVT
R/W
A one enables the VT1 fault status to be indicated in pin OVT.
3
EN_V3_FAULT
R/W
A one enables the V3 fault status to be indicated in pin VOLT_FUALT
pin.
2
EN_V2_FAULT
R/W
A one enables the V2 fault status to be indicated in pin VOLT
_FUALT.
1
EN_V1_FAULT
R/W
A one enables the V1 fault status to be indicated in pin VOLT
_FUALT.
0
EN_VCC_FAULT
R/W
A one enables the VCC fault status to be indicated in pin VOLT
_FUALT.
6.13 REAL TIME Fault Status Register 1  Index 36h
Power on default: 00h
Bit
Name
Attribute
Description
7
FAN2_FAULT
RO
A one indicates fan2 count limit exceeding.
6
FAN1_FAULT
RO
A one indicates fan1 count limit exceeding.
5
VT2_OVT
RO
This bit will set to 1 from high limit of VT2 is exceeded until the
temperature2 is under the VT2 hysteresis Limit
4
VT1_OVT
RO
This bit will set to 1 from high limit of VT1 is exceeded until the
temperature1 is under the VT1 hysteresis Limit
3
V3_FAULT
RO
A one indicates a high or low limit of V3 exceeding.
2
V2_FAULT
RO
A one indicates a high or low limit of V2 exceeding.
1
V1_FAULT
RO
A one indicates a high or low limit of V1 exceeding.
0
VCC_FAULT
RO
A one indicates a high or low limit of VCC exceeding.
20
V0.25P
Fintek
Feature Integration Technology Inc.
F75373
6.14 5.1 CHIPID(1) Register – Index 5Ah
Power-on default [7:0] =0000_0010b
Bit
7-0
Name
Attribute
CHIPID
RO
Description
Chip ID, High byte (8’h02).
6.15 CHIPID(2) Register – Index 5Bh
Power-on default [7:0] =0000_0100b
Bit
7-0
Name
Attribute
CHIPID
RO
Description
Chip ID, Low byte (8’h04).
6.16 VENDOR ID(1) Register – Index 5Dh
Power-on default [7:0] =0001_1001b
Bit
7-0
Name
Attribute
VENDOR1
RO
Description
Vendor ID, 8’h19
6.17 VENDOR ID(2) Register – Index 5Eh
Power-on default [7:0] =0011_0100b
Bit
7-0
Name
VENDOR2
Attribute
RO
Description
Vendor ID, 8h34
6.18 Reset Timer Control Register -- Index 60h
Power on default: 00h
Bit
7-6
Name
FAN2_MODE
Attribute
R/W
Description
00: FAN2 operates in SPEED mode. PWMOUT2 duty-cycle is
21
V0.25P
Fintek
Feature Integration Technology Inc.
F75373
automatically adjusted according to FAN2 EXPECT register.
01: FAN2 operates in TEMPERATURE mode. PWMOUT2 duty-cycle
is automatically adjusted according to FAN2 EXPECT register, which
will be automatically loaded into preset values according to the
current temperature. (When PIN3 power-on trapped to 1, this mode
is selected after power-on.)
1X: FAN2 operates in MANUAL mode. Software set the PWMOUT2
duty-cycle directly.
5-4
FAN1_MODE
R/W
00: FAN1 operates in SPEED mode. PWMOUT1 duty-cycle is
automatically adjusted according to FAN1 EXPECT register.
01: FAN1 operates in TEMPERATURE mode. PWMOUT1 duty-cycle
is automatically adjusted according to FAN1 EXPECT register, which
will be automatically loaded into preset values according to the
current temperature. (When PIN3 power-on trapped to 1, this mode
is selected after power-on.)
1X: FAN1 operates in MANUAL mode. Software set the PWMOUT1
duty-cycle directly.
3
Reserved
2
KEEP_DROP_DU
R/W
TY2
1
hold.
KEEP_DROP_DU
R/W
TY1
0
Set to 1, keep PWMOUT2 duty-cycle decrease to DROP duty and
Set to 1, keep PWMOUT1 duty-cycle decrease to DROP duty and
hold.
EN_RESET_TIME
R/W
R
Set to 1, enable interface_idle timer. Set to 0, disable the timer.
When the timer is enabled, if software doesn’t access the this chip
through GP_CLK and GP_DATA, the reset timer starts to count down
according to the value set in INDEX 62H. When it counts down to
zero, INDEX[72H, 73H] will be loaded into INDEX[74H,75H].
6.19 Fan Fault Time Register -- Index 61h
Power on default: B4h
Bit
7-0
Name
F_FAULT_TIME
Attribute
R/W
Description
This register determines the time of fan fault. Two conditions cause
fan fault event:
22
V0.25P
Fintek
Feature Integration Technology Inc.
F75373
(1). When PWM_Duty reaches FFh, if the fan speed count can’t
reach the fan expect count in the time.
(2). When PWM_Duty reaches 00h, if the fan speed count can’t
reach the fan expect count in the time.
The unit of this register is 1 second. The default value is 180
seconds.
6.20 RESET-Timer Time Register -- Index 62h
Power on default: 09h
Bit
7-0
Name
F_RESET_TIME
Attribute
R/W
Description
Interface idle time. The unit of this register is 1 minute. The default
value is 10 minute. More details in INDEX 60H.
6.21 FAN STEP Time defined Register -- Index 63h
Power on default: 00h
Bit
Name
Attribute
Description
7-4
Reserved
RO
Read back will be 0
3:0
TIME_STEP
R/W
This value determines the increasing or decreasing speed of
PWM_Duty The smaller value, the faster speed.
6.22 VT1 OFFSET Register -- Index 64h
Power on default: 09h
Bit
Name
7-0
T1OFFSET
Attribute
R/W
Description
VT1 temperature offset register. The offset value is representative in
2’s complement. The real temperature value will be added by this
offset and then will be put into temperature reading ( Value RAM
14h). The offset ranges from -128ºC to +127ºC.
7Fh : +127ºC.
23
V0.25P
Fintek
Feature Integration Technology Inc.
F75373
01h : +5ºC.
00h : +0ºC.
FFh : -1ºC.
FEh : -2ºC.
80h : -128ºC.
6.23 VT2 OFFSET Register -- Index 65h
Power on default: 09h
Bit
7-0
Name
T2OFFSET
Attribute
R/W
Description
VT2 temperature offset register. The offset value is representative in
2’s complement. The real temperature value will be added by this
offset and then will be put into temperature reading ( Value RAM
15h). The offset ranges from -128ºC to +127ºC.
7Fh : +127ºC.
01h : +5ºC.
00h : +0ºC.
FFh : -1ºC.
FEh : -2ºC.
80h : -128ºC.
6.24 Reserved Register  Index 66h ~ 68h (FINTEK Use ONLY)
6.25 PWMOUT1 RAISE DUTY-CYCLE  Index 69h
Power on default: 30h
Bit
7-0
Name
FAN1_RAISE_DUT
Attribute
R/W
Description
PWMOUT1 will increasing duty-cycle from 0 to this value rapidly.
Y
24
V0.25P
Fintek
Feature Integration Technology Inc.
F75373
6.26 PWMOUT2 RAISE DUTY-CYCLE  Index 6Ah
Power on default: 30h
Bit
7-0
Name
FAN2_RAISE_DUT
Attribute
R/W
Description
PWMOUT2 will increasing duty-cycle from 0 to this value rapidly
Y
6.27 PWMOUT1 DROP DUTY-CYCLE  Index 6Bh
Power on default: 25h
Bit
7-0
Name
FAN1_DROP_DUT
Attribute
Description
R/W
PWMOUT1 will decreasing duty-cycle to 0 from this value rapidly or
Y
keep duty-cycle in this value when CR60 bit1 set to 1.
6.28 PWMOUT2 DROP DUTY-CYCLE  Index 6Ch
Power on default: 25h
Bit
7-0
Name
FAN2_DROP_DUT
Attribute
Description
R/W
PWMOUT2 will decreasing duty-cycle to 0 from this value rapidly or
Y
keep duty-cycle in this value when CR60 bit2 set to 1.
6.29 Reserved Register  Index 6Dh ~ 6Fh (FINTEK Use ONLY)
6.30 FAN1 Full Speed Count Register 0  Index 70h
Power on default: 0000_0000b
Bit
7-0
Name
FAN1_FULL(MSB)
Attribute
RO
Description
When power on, the PWMOUT1 will output full duty cycle (FFh) to
enable system FAN. After 10 seconds when detecting FANIN1
signal, assuming the fan has been fully turned on, the fan speed
count detected will be recorded in the register. If there is no signal on
25
V0.25P
Fintek
Feature Integration Technology Inc.
F75373
FANIN1 after power on, the PWMOUT1 will keep outputting FFh duty
cycle.
6.31 FAN1 full speed Count Register 1 Index71h
Power on default: 1111_1111b
Bit
7-0
Name
FAN1_FULL
Attribute
RO
(LSB)
Description
When power on, the PWMOUT1 will output full duty cycle (FFh) to
enable system FAN. After 10 seconds when detecting FANIN1
signal, assuming the fan has been fully turned on, the fan speed
count detected will be recorded in the register. If there is no signal on
FANIN1 after power on, the PWMOUT1 will keep outputting FFh duty
cycle.
6.32 FAN1 expect timeout speed Register  Index 72h
Power on default: 0000_0001b
Bit
7-0
Name
FAN1_TSPEED
Attribute
R/W
(MSB)
Description
The fan1 timeout count, when software idle timeout is happen, this
count will be load to FAN1 expect register. The default count is 11/8
of FAN1_FULL reg. ( 73% of full speed).
This register is only valid at HALF-AUTOMATIC(SPEED) mode.
6.33 FAN1 expect timeout speed Register  Index 73h
Power on default: 0101_1101b
Bit
Name
7-0
FAN1_TSPEED
(LSB)
Attribute
R/W
Description
The fan1 timeout count, when software idle timeout is happen, this
count will be load to FAN1 expect register. The default count is 11/8
of FAN1_FULL reg. ( 73% of full speed).
This register is only valid at HALF-AUTOMATIC(SPEED) mode.
26
V0.25P
Fintek
Feature Integration Technology Inc.
F75373
6.34 FAN1 expect count Register-- Index 74h
Power on default [7:0] = 0000_0001b
Bit
7-0
Name
Attribute
FAN1_EXPECT
R/W
(MSB)
Description
User expect fan1 count value, program this register to control the
expect fan1 speed
6.35 FAN1 expect count Register-- Index 75h
Power on default [7:0] = 0101_1101b
Bit
7-0
Name
FAN1_EXPECT
Attribute
R/W
(LSB)
Description
User expect fan1 count value, program this register to control the
expect fan1 speed.
6.36 FAN1 PWM_duty -- Index 76h
Power on default: 1111_1111b
Bit
7-0
Name
PWM_DUTY1
Attribute
R/W
Description
PWMOUT1 duty cycle. This register is programmable at Manual
mode. At SPEED or TEMPERATURE mode, this register reflects
current PWMOUT duty-cycle.
6.37 FAN2 Full speed Register 0  Index 80h
Power on default: 0000_0000b
Bit
7-0
Name
FAN2_FULL(MSB)
Attribute
R/W
Description
While PIN4 is set to PWMOUT mode, the PWMOUT2 will output full
duty cycle (FFh) to enable system FAN. After 10 seconds when
detecting FANIN1 signal, assuming the fan has been fully turned
on, the fan speed count detected will be recorded in the register. If
there is no signal on FANIN2 after power on, the PWMOUT2 will
keep outputting FFh duty cycle.
27
V0.25P
Fintek
Feature Integration Technology Inc.
F75373
6.38 FAN2 full speed Register 1 Index 81h
Power on default: 1111_1111b
Bit
7-0
Name
Attribute
FAN2_FULL
R/W
(LSB)
Description
While PIN4 is set to PWMOUT mode, the PWMOUT2 will output full
duty cycle (FFh) to enable system FAN. After 15 seconds, assuming
the fan has been fully turned on, the fan speed count detected will be
recorded in the register.
6.39 FAN2 expect timeout speed Register  Index 82h
Power on default: 0000_0001b
Bit
7-0
Name
Attribute
FAN2_TSPEED
R/W
Description
The fan2 timeout count, when software idle timeout is happen, this
count will be load to FAN1 expect register. The default count is 11/8
of FAN2_FULL reg. ( 73% of full speed).
This register is only valid at HALF-AUTOMATIC(SPEED) mode.
6.40 FAN2 expect timeout speed Register  Index 83h
Power on default: 0101_1101b
Bit
7-0
Name
Attribute
FAN2_TSPEED
R/W
(LSB)
Description
The fan2 timeout count, when software idle timeout is happen, this
count will be load to FAN2 expect register. The default count is 11/8
of FAN2_FULL reg. ( 73% of full speed).
This register is only valid at HALF-AUTOMATIC(SPEED) mode.
6.41 FAN2 expect count Register-- Index 84h
Power on default [7:0] = 0000_0001b
Bit
Name
Attribute
Description
28
V0.25P
Fintek
Feature Integration Technology Inc.
F75373
7-0
FAN2_EXPECT
R/W
(MSB)
User expect fan2 count value, program this register to control the
expect fan2 speed
6.42 FAN2 expect count Register-- Index 85h
Power on default [7:0] = 0101_1101b
Bit
7-0
Name
FAN2_EXPECT
Attribute
R/W
(LSB)
Description
User expect fan2 count value, program this register to control the
expect fan2 speed
6.43 PWM_duty -- Index 86h
Power on default: 1111_1111b
Bit
7-0
Name
PWM_DUTY2
Attribute
R/W
Description
PWMOUT2 duty cycle. This register is programmable at MANUAL
mode. At SPEED or TEMPERATURE mode, this register reflects
current PWMOUT duty-cycle.
6.44 GPIOx Output Control Register – Index 90h
Power-on default [7:0] =0000_0000b
Bit
Name
Attribute
Description
7-4
Reserved
RO
Read back will be 0;
3
GPIO3_OCTRL
R/W
GPIO3 output control. Set to 1 for output function. Set to 0 for input
function(default).
2
GPIO2_OCTRL
R/W
GPIO2 output control. If this pin serves as IRQ/SMI#, this bit has no
effect. Set to 1 for output function. Set to 0 for input function(default).
1
GPIO1_OCTRL
R/W
GPIO1 output control. Set to 1 for output function. Set to 0 for input
function(default).
0
GPIO0_OCTRL
R/W
GPIO0 output control. Set to 1 for output function. Set to 0 for input
function(default).
29
V0.25P
Fintek
Feature Integration Technology Inc.
F75373
6.45 GPIOx Output Data Register – Index 91h
Power-on default [7:0] =0000_0000b
Bit
Name
Attribute
Description
7-4
Reserved
RO
Read back will be 0;
3
GPIO3_ODATA
R/W
GPIO3 output data.
2
GPIO2_ODATA
R/W
GPIO2 output data.
1
GPIO1_ODATA
R/W
GPIO1 output data.
0
GPIO0_ODATA
R/W
GPIO0 output data.
6.46 GPIO1x Input Status Register – Index 92h
Power-on default [7:0] = N.A.
Bit
Name
Attribute
Description
7-4
Reserved
RO
Read back will be 0
3
GPIO3_PSTS
RO
Read the GPIO3 data on the pin.
2
GPIO2_PSTS
RO
Read the GPIO2 data on the pin. If this pin serves as IRQ/SMI#, this
bit always indicates 0, that is, read will return 0.
1
GPIO1_PSTS
RO
Read the GPIO1 data on the pin.
0
GPIO0_PSTS
RO
Read the GPIO0 data on the pin.
INDEX A0 -- AD registers – FAN1 CONTROL v.s. TEMPERATURE 1
6.47 VT1 BOUNDARY 1 TEMPERATURE – Index A0h
Power-on default [7:0] =0011_1100b
Bit
7-0
Name
BOUND1TMP
Attribute
R/W
Description
The 1st BOUNDARY temperature for VT1 in temperature mode.
When VT1 temperature is exceed this boundary, FAN1 segment 1
speed count registers(INDEX A4h, A5h) will be loaded into FAN1
expect count registers(INDEX 74h,75h).
When VT1 temperature is below this boundary, FAN1 segment 2
speed count registers(INDEX A6h, A7h) will be loaded into FAN1
30
V0.25P
Fintek
Feature Integration Technology Inc.
F75373
expect count registers(INDEX 74h,75h).
6.48 VT1 BOUNDARY 2 TEMPERATURE – Index A1h
Power-on default [7:0] =0011_0010b
Bit
7-0
Name
BOUND2TMP
Attribute
R/W
Description
nd
The 2 BOUNDARY temperature for VT1 in temperature mode.
When VT1 temperature is exceed this boundary, FAN1 segment 2
speed count registers(INDEX A6h, A7h) will be loaded into FAN1
expect count registers(INDEX 74h,75h).
When VT1 temperature is below this boundary, FAN1 segment 3
speed count registers(INDEX A8h, A9h) will be loaded into FAN1
expect count registers(INDEX 74h,75h).
6.49 VT1 BOUNDARY 3 TEMPERATURE – Index A2h
Power-on default [7:0] =0010_1000b
Bit
7-0
Name
BOUND3TMP
Attribute
R/W
Description
rd
The 3 BOUNDARY temperature for VT1 in temperature mode.
When VT1 temperature is exceed this boundary, FAN1 segment 3
speed count registers(INDEX A8h, A9h) will be loaded into FAN1
expect count registers(INDEX 74h,75h).
When VT1 temperature is below this boundary, FAN1 segment 4
speed count registers(INDEX AAh, ABh) will be loaded into FAN1
expect count registers(INDEX 74h,75h).
6.50 VT1 BOUNDARY 4 TEMPERATURE – Index A3h
Power-on default [7:0] =0001_1110b
Bit
Name
7-0
BOUND4TMP
Attribute
R/W
Description
The 4th BOUNDARY temperature for VT1 in temperature mode.
When VT1 temperature is exceed this boundary, FAN1 segment 4
speed count registers(INDEX AAh, ABh) will be loaded into FAN1
31
V0.25P
Fintek
Feature Integration Technology Inc.
F75373
expect count registers(INDEX 74h,75h).
When VT1 temperature is below this boundary, FAN1 segment 5
speed count registers(INDEX ACh, ADh) will be loaded into FAN1
expect count registers(INDEX 74h,75h).
6.51 FAN1 SEGMENT 1 SPEED COUNT (MSB) – Index A4h
Power-on default [7:0] =0000_0000b
Bit
7-0
Name
SEC1SPEED
Attribute
R/W
(MSB)
Description
st
The MSB of 1 expected fan speed for FAN1 in temperature mode.
After detecting FAN1 full speed, 00h will be loaded into this register.
6.52 FAN1 SEGMENT 1 SPEED COUNT (LSB) – Index A5h
Power-on default [7:0] =0000_0000b
Bit
7-0
Name
SEC1SPEED
Attribute
R/W
(LSB)
Description
st
The LSB of 1 expected fan speed for FAN1 in temperature mode.
After detecting FAN1 full speed, 00h will be loaded into this register.
6.53 FAN1 SEGMENT 2 SPEED COUNT (MSB) – Index A6h
Power-on default [7:0] =0000_0000b
Bit
7-0
Name
SEC2SPEED
Attribute
R/W
(MSB)
Description
nd
The MSB of 2 expected fan speed for FAN1 in temperature mode.
After detecting FAN1 full speed count, the high byte of 112.5% FAN1
FULL SPEED COUND will be loaded into this register. (ie. 88% of
FULL SPEED RPM)
6.54 FAN1 SEGMENT 2 SPEED COUNT (LSB) – Index A7h
Power-on default [7:0] =0000_0000b
Bit
Name
Attribute
Description
32
V0.25P
Fintek
Feature Integration Technology Inc.
F75373
7-0
SEC2SPEED
R/W
(LSB)
nd
The LSB of 2 expected fan speed for FAN1 in temperature mode.
After detecting FAN1 full speed count, the low byte of 112.5% FAN1
FULL SPEED COUND will be loaded into this register.
6.55 FAN1 SEGMENT 3 SPEED COUNT (MSB) – Index A8h
Power-on default [7:0] =0000_0000b
Bit
7-0
Name
SEC3SPEED
Attribute
R/W
(MSB)
Description
rd
The MSB of 3 expected fan speed for FAN1 in temperature mode.
After detecting FAN1 full speed count, the high byte of 131.25% FAN1
FULL SPEED COUND will be loaded into this register. (ie. 76% of
FULL SPEED RPM)
6.56 FAN1 SEGMENT 3 SPEED COUNT (LSB) – Index A9h
Power-on default [7:0] =0000_0000b
Bit
7-0
Name
SEC3SPEED
Attribute
R/W
(LSB)
Description
The LSB of 3rd expected fan speed for FAN1 in temperature mode.
After detecting FAN1 full speed count, the low byte of 131.25% FAN1
FULL SPEED COUND will be loaded into this register. (ie. 76% of
FULL SPEED RPM)
6.57 FAN1 SEGMENT 4 SPEED COUNT (MSB) – Index AAh
Power-on default [7:0] =0000_0000b
Bit
7-0
Name
SEC4SPEED
(MSB)
Attribute
R/W
Description
The MSB of 4th expected fan speed for FAN1 in temperature mode.
After detecting FAN1 full speed count, the high byte of 156.25% FAN1
FULL SPEED COUND will be loaded into this register. (ie. 64% of
FULL SPEED RPM)
33
V0.25P
Fintek
Feature Integration Technology Inc.
F75373
6.58 FAN1 SEGMENT 4 SPEED COUNT (LSB) – Index ABh
Power-on default [7:0] =0000_0000b
Bit
7-0
Name
SEC4SPEED
Attribute
R/W
(LSB)
Description
th
The LSB of 4 expected fan speed for FAN1 in temperature mode.
After detecting FAN1 full speed count, the low byte of 156.25% FAN1
FULL SPEED COUND will be loaded into this register. (ie. 64% of
FULL SPEED RPM)
6.59 FAN1 SEGMENT 5 SPEED COUNT (MSB) – Index ACh
Power-on default [7:0] =0000_0000b
Bit
7-0
Name
SEC5SPEED
R/W
R/W
(MSB)
Description
th
The MSB of 5 expected fan speed for FAN1 in temperature mode.
After detecting FAN1 full speed count, FFh will be loaded into this
register.
6.60 FAN1 SEGMENT 5 SPEED COUNT (LSB) – Index ADh
Power-on default [7:0] =0000_0000b
Bit
7-0
Name
SEC5SPEED
Attribute
R/W
(LSB)
Description
th
The LSB of 5 expected fan speed for FAN1 in temperature mode.
After detecting FAN1 full speed count, FFh will be loaded into this
register.
INDEX B0 -- BD registers – FAN2 CONTROL v.s. TEMPERATURE 2
6.61 VT2 BOUNDARY 1 TEMPERATURE – Index B0h
Power-on default [7:0] =0000_0000b
Bit
Name
Attribute
Description
34
V0.25P
Fintek
Feature Integration Technology Inc.
F75373
7-0
BOUND1TMP
R/W
st
The 1 BOUNDARY temperature for VT2 in temperature mode.
When VT2 temperature is exceed this boundary, FAN2 segment 1
speed count registers(INDEX B4h, B5h) will be loaded into FAN1
expect count registers(INDEX 84h,85h).
When VT2 temperature is below this boundary, FAN2 segment 2
speed count registers(INDEX B6h, B7h) will be loaded into FAN2
expect count registers(INDEX 84h,85h).
6.62 VT2 BOUNDARY 2 TEMPERATURE – Index B1h
Power-on default [7:0] =0000_0000b
Bit
7-0
Name
BOUND2TMP
Attribute
R/W
Description
nd
The 2 BOUNDARY temperature for VT2 in temperature mode.
When VT2 temperature is exceed this boundary, FAN2 segment 2
speed count registers(INDEX B6h, B7h) will be loaded into FAN2
expect count registers(INDEX 84h,85h).
When VT2 temperature is below this boundary, FAN2 segment 3
speed count registers(INDEX B8h, B9h) will be loaded into FAN2
expect count registers(INDEX 84h,85h).
6.63 VT2 BOUNDARY 3 TEMPERATURE – Index B2h
Power-on default [7:0] =0000_0000b
Bit
7-0
Name
BOUND3TMP
Attribute
R/W
Description
rd
The 3 BOUNDARY temperature for VT2 in temperature mode.
When VT2 temperature is exceed this boundary, FAN2 segment 3
speed count registers(INDEX B8h, B9h) will be loaded into FAN2
expect count registers(INDEX 84h,85h).
When VT2 temperature is below this boundary, FAN2 segment 4
speed count registers(INDEX BAh, BBh) will be loaded into FAN2
expect count registers(INDEX 84h,85h).
35
V0.25P
Fintek
Feature Integration Technology Inc.
F75373
6.64 VT2 BOUNDARY 4 TEMPERATURE – Index B3h
Power-on default [7:0] =0000_0000b
Bit
7-0
Name
BOUND4TMP
Attribute
R/W
Description
th
The 4 BOUNDARY temperature for VT2 in temperature mode.
When VT2 temperature is exceed this boundary, FAN2 segment 4
speed count registers(INDEX BAh, BBh) will be loaded into FAN2
expect count registers(INDEX 84h,85h).
When VT2 temperature is below this boundary, FAN2 segment 5
speed count registers(INDEX BCh, BDh) will be loaded into FAN2
expect count registers(INDEX 84h,85h).
6.65 FAN2 SEGMENT 1 SPEED COUNT (MSB) – Index B4h
Power-on default [7:0] =0000_0000b
Bit
Name
7-0
SEC1SPEED
Attribute
R/W
(MSB)
Description
The MSB of 1st expected fan speed for FAN2 in temperature mode.
After detecting FAN2 full speed, 00h will be loaded into this register.
6.66 FAN2 SEGMENT 1 SPEED COUNT (LSB) – Index B5h
Power-on default [7:0] =0000_0000b
Bit
7-0
Name
SEC1SPEED
Attribute
R/W
(LSB)
Description
st
The LSB of 1 expected fan speed for FAN2 in temperature mode.
After detecting FAN2 full speed, 00h will be loaded into this register.
6.67 FAN2 SEGMENT 2 SPEED COUNT (MSB) – Index B6h
Power-on default [7:0] =0000_0000b
Bit
7-0
Name
SEC2SPEED
Attribute
R/W
Description
nd
The MSB of 2 expected fan speed for FAN2 in temperature mode.
36
V0.25P
Fintek
Feature Integration Technology Inc.
F75373
(MSB)
After detecting FAN2 full speed count, the high byte of 112.5% FAN2
FULL SPEED COUND will be loaded into this register. (ie. 88% of
FULL SPEED RPM)
6.68 FAN2 SEGMENT 2 SPEED COUNT (LSB) – Index B7h
Power-on default [7:0] =0000_0000b
Bit
7-0
Name
SEC2SPEED
Attribute
R/W
(LSB)
Description
nd
The LSB of 2 expected fan speed for FAN2 in temperature mode.
After detecting FAN2 full speed count, the low byte of 112.5% FAN2
FULL SPEED COUND will be loaded into this register. (ie. 88% of
FULL SPEED RPM)
6.69 FAN2 SEGMENT 3 SPEED COUNT (MSB) – Index B8h
Power-on default [7:0] =0000_0000b
Bit
Name
7-0
SEC3SPEED
Attribute
R/W
(MSB)
Description
The MSB of 3rd expected fan speed for FAN2 in temperature mode.
After detecting FAN2 full speed count, the high byte of 131.25% FAN2
FULL SPEED COUND will be loaded into this register. (ie. 76% of
FULL SPEED RPM)
6.70 FAN2 SEGMENT 3 SPEED COUNT (LSB) – Index B9h
Power-on default [7:0] =0000_0000b
Bit
Name
7-0
SEC3SPEED
(LSB)
Attribute
R/W
Description
The LSB of 3rd expected fan speed for FAN2 in temperature mode.
After detecting FAN2 full speed count, the low byte of 131.25% FAN2
FULL SPEED COUND will be loaded into this register. (ie. 76% of
FULL SPEED RPM)
37
V0.25P
Fintek
Feature Integration Technology Inc.
F75373
6.71 FAN2 SEGMENT 4 SPEED COUNT (MSB) – Index BAh
Power-on default [7:0] =0000_0000b
Bit
7-0
Name
SEC4SPEED
Attribute
R/W
(MSB)
Description
th
The MSB of 4 expected fan speed for FAN2 in temperature mode.
After detecting FAN2 full speed count, the high byte of 156.25% FAN2
FULL SPEED COUND will be loaded into this register. (ie. 64% of
FULL SPEED RPM)
6.72 FAN2 SEGMENT 4 SPEED COUNT (LSB) – Index BBh
Power-on default [7:0] =0000_0000b
Bit
7-0
Name
SEC4SPEED
Attribute
R/W
(LSB)
Description
th
The LSB of 4 expected fan speed for FAN2 in temperature mode.
After detecting FAN2 full speed count, the low byte of 156.25% FAN2
FULL SPEED COUND will be loaded into this register. (ie. 64% of
FULL SPEED RPM)
6.73 FAN2 SEGMENT 5 SPEED COUNT (MSB) – Index BCh
Power-on default [7:0] =0000_0000b
Bit
Name
7-0
SEC5SPEED
Attribute
R/W
(MSB)
Description
The MSB of 5th expected fan speed for FAN2 in temperature mode.
After detecting FAN2 full speed count, FFh will be loaded into this
register.
6.74 FAN2 SEGMENT 5 SPEED COUNT (LSB) – Index BDh
Power-on default [7:0] =0000_0000b
Bit
Name
Attribute
Description
38
V0.25P
Fintek
Feature Integration Technology Inc.
F75373
7-0
SEC5SPEED
R/W
(LSB)
th
The LSB of 5 expected fan speed for FAN2 in temperature mode.
After detecting FAN2 full speed count, FFh will be loaded into this
register.
6.75 Reserved Register – Index F0h ~ FFh (Fintek Use Only)
7 Electron Characteristic
7.1
Absolute Maximum Ratings
PARAMETER
RATING
UNIT
Power Supply Voltage
-0.5 to 4.0
V
Input Voltage
-0.5 to 5.5
V
Operating Temperature
0 to +70
°C
Storage Temperature
-55 to +150
°C
Note: Exposure to conditions beyond those listed under Absolute Maximum Ratings may adversely affect
the life and reliability of the device.
39
V0.25P
Fintek
Feature Integration Technology Inc.
F75373
7.2
DC Characteristics
(Ta = 0° C to 70°C, VDD = 3.3V ± 10%, VSS = 0V, Tja = 0.73 + Ta (air flow = 0 LPF), Tja(max) = 150°C )
PARAMETER
SYM.
MIN.
TYP.
MAX.
UNIT
CONDITIONS
I/O12t - TTL level bi-directional pin with source-sink capability of 12 mA
Input Low Voltage
VIL
Input High Voltage
VIH
Output Low Voltage
VOL
Output High Voltage
VOH
Input High Leakage
ILIH
Input Low Leakage
ILIL
0.8
2.0
V
V
0.4
V
IOL = 12 mA
V
IOH = - 12 mA
+10
µA
VIN = VDD
-10
µA
VIN = 0V
2.4
I/O12ts - TTL level bi-directional pin with source-sink capability of 12 mA and schmitt-trigger level
input
Input Low Threshold Voltage
Vt-
0.5
0.8
Input High Threshold Voltage
Vt+
1.6
2.0
Hysteresis
VTH
0.5
1.2
Output Low Voltage
VOL
Output High Voltage
VOH
Input High Leakage
ILIH
Input Low Leakage
ILIL
1.1
V
VDD = 3.3 V
V
VDD = 3.3 V
V
VDD = 3.3 V
V
IOL = 12 mA
V
IOH = - 12 mA
+10
µA
VIN = VDD
-10
µA
VIN = 0V
2.4
0.4
2.4
40
V0.25P
Fintek
Feature Integration Technology Inc.
F75373
7.2 DC Characteristics, continued
PARAMETER
SYM.
MIN.
TYP.
MAX.
UNIT
CONDITIONS
OUT12t - TTL level output pin with source-sink capability of 12 mA
Output Low Voltage
VOL
Output High Voltage
VOH
0.4
V
IOL = 12 mA
V
IOH = -12 mA
V
IOL = 8 mA
V
IOL = 12 mA
0.4
V
IOL = 16 mA
0.8
V
2.4
OD8 - Open-drain output pin with sink capability of 8 mA
Output Low Voltage
VOL
0.4
OD12 - Open-drain output pin with sink capability of 12 mA
Output Low Voltage
VOL
0.4
OD16 - Open-drain output pin with sink capability of 16 mA
Output Low Voltage
VOL
INt - TTL level input pin
Input Low Voltage
VIL
Input High Voltage
VIH
Input High Leakage
ILIH
+10
µA
VIN = VDD
Input Low Leakage
ILIL
-10
µA
VIN = 0 V
2.0
V
INts - TTL level Schmitt-triggered input pin
Input Low Threshold Voltage
Vt-
0.5
0.8
1.1
V
VDD = 3.3V
Input High Threshold Voltage
Vt+
1.6
2.0
2.4
V
VDD = 3.3V
Hysteresis
VTH
0.5
1.2
V
VDD = 3.3 V
Input High Leakage
ILIH
+10
µA
VIN = VDD
Input Low Leakage
ILIL
-10
µA
VIN = 0 V
7.3
AC Characteristics
t
SCL
t
t
R
R
SCL
t HD;SDA
t
HD;DAT
t
SU;STO
SDA IN
VALID DATA
t
SU;DAT
SDA OUT
Serial Bus Timing Diagram
41
V0.25P
Fintek
Feature Integration Technology Inc.
F75373
Serial Bus Timing
PARAMETER
SYMBOL
MIN.
-
MAX.
UNIT
SCL clock period
t SCL
10
uS
Start condition hold time
tHD;SDA
4.7
uS
Stop condition setup-up time
tSU;STO
4.7
uS
DATA to SCL setup time
tSU;DAT
120
nS
DATA to SCL hold time
tHD;DAT
5
nS
SCL and SDA rise time
tR
1.0
uS
SCL and SDA fall time
tF
300
nS
8 Ordering Information
Part Number
Package Type
Production Flow
F75373S
16 PIN SOP
Commercial, 0°C to +70°C
F75373SG
16 PIN SOP (Green Package)
Commercial, 0°C to +70°C
9 Package Dimensions (16SOP 150mil)
42
V0.25P
Fintek
Feature Integration Technology Inc.
F75373
Feature Integration Technology Inc.
Headquarters
Taipei Office
3F-7, No 36, Tai Yuan St.,
Bldg. K4, 7F, No.700, Chung Cheng Rd.,
Chupei City, Hsinchu, Taiwan 302, R.O.C.
Chungho City, Taipei, Taiwan 235, R.O.C.
TEL : 886-3-5600168
TEL : 866-2-8227-8027
FAX : 886-3-5600166
FAX : 866-2-8227-8037
www: http://www.fintek.com.tw
Please note that all datasheet and specifications are subject to change without notice. All the trade
marks of products and companies mentioned in this datasheet belong to their respective owner
43
V0.25P
Fintek
Feature Integration Technology Inc.
F75373
VOLTAGE MONITOR
ADDRESS SELECT
R2
VCC3V
100K
VIN1
R3
PWMOUT1 R1
VDD1
(2.0V)
VDD2
(2.5V)
VDD3
(1.5V)
100K
10K
R28
100K
R4
R1 ON
ADDRESS=0x5Ch
R1 OFF ADDRESS=0X5Ah
R28 optional
VCC3V
VCC3V
C1
R6
R7
R8
R9
R10
R11
4.7K
4.7K
4.7K
4.7K
4.7K
4.7K
SCLK
SDATA
0.1U
R5
FANIN1
FANIN2/GPIO0
PWMOUT1/ADDR_TRAP
PWMOUT2/GPIO1
FAN_FAULT#/SMI#/GPIO2
VOLT_FAULT#/OVT#/GPIO3
SCLK
SDATA
VCC
VT1
VT2
VREF
VIN1
VIN2
VIN3
GND
16
15
14
13
12
11
10
9
100K
C2
4.7U
R12
U1
FANIN1 1
2
PWMOUT1
3
4
5
6
SCLK
7
SDATA 8
150K
VIN2
47K
VIN3
T1
T2
VREF
VIN1
VIN2
VIN3
R13
100K
VIN1,VIN2,VIN3 SIGNALS BEST INPUT LEVEL IS ABOUT 1V
F75373S
R16 4.7K
R17 4.7K
VREF
D1
1N4148
Q1
3906
PWMOUT1
R20
100
Q2
2N7002
<PCB Footprint>
JP1
3
2
1
4.7K
R14
10K THERMISTOR
RT2
VREF
R19
FANIN1
27K
R21
R15
RT1
10K 1%
T2
R18
C3
47U
TEMPERATURE MONITOR
t
T1
+12V
10K 1%
t
FAN CONTROL
10K THERMISTOR
10K
CON3
Title
Feature Integration Technology Inc.
Size
A
Date:
1
Document Number
F75373S
Monday , April 14, 2003
Rev
0.1
Sheet
1
of
1
V0.25P