Cooper-Wheelock E Series Low-Profile Speakers & Speaker Strobes Features • ADA/NFPA/UFC/ANSI compliant • Complies with OSHA 29 Part 1910.165 • Wall mount models are available with Description E90 Series Speaker Strobe Cooper-Wheelock’s Series E Low Profile Speakers and Speaker Strobes are designed for high efficiency sound output, with dual voltage (25/70 VRMS) capability and field selectable taps from 1/8 to 2 watts. The low profile design incorporates a speaker mounting plate for faster and easier installation. Each model has a built-in level adjustment feature and an aesthetic two (2) screw grille cover. The Series E Speaker Strobe models incorporate the Low Current draw Series RSS Strobes. E70 Series Speaker Strobe Strobe options for wall mount models include 15/75 or Cooper-Wheelock’s patented MCW multi-candela strobe with field selectable candela settings of 15/30/75/110cd or the high intensity MCWH strobe with field selectable 135/185cd. Ceiling mount models are available in Cooper-Wheelock’s patented MCC multi-candela ceiling strobe with field selectable intensities Multi-Candela Indicator of 15/30/75/95cd or the high intensity MCCH (bottom of Strobe Lens) strobe with field selectable 115/177cd. Series E Speakers and Speaker Strobes provide high audio output with clear audibility and are designed to meet the critical needs of the life safety industry for effective emergency voice communications, tone signaling and visible signaling to alert the hearing impaired. The strobe portion of all Series E Speaker Strobes may be synchronized when used in conjunction with the Cooper-Wheelock SM, DSM Sync Modules or a power supply with Patented Cooper-Wheelock Sync Protocol. CooperWheelock’s synchronized strobes offer an easy way to comply with ADA recommendations concerning photosensitive epilepsy. Series E Speaker Strobes are UL Listed for indoor use under Standard 1971 (Signaling Devices for the Hearing-Impaired) and Standard 1480 (Speaker Appliances), and use a Xenon flashtube with solid state circuitry enclosed in a rugged Lexan® lens to provide maximum reliability for effective visual signaling. All inputs are supervised and employ IN/OUT wiring terminals for fast installation using #12 to #18 AWG wiring. Color options for the E Series Speakers and Speaker Strobes offered are colored red or white. E Low Profile Speakers & Strobes CS-2242 09/01/06 Page 1 of 4 Field Selectable Candela Settings of 15/30/75/110cd or 135/185cd (MultiCandela models), or 15/75cd (Single Candela model) • Ceiling mount models are available with field selectable candela settings of 15/30/75/95cd or 115/177cd (multicandela models) • Strobes produce 1 flash per second over the regulated voltage range • 24 VDC with wide UL “Regulated Voltage” using filtered DC or unfiltered VRMS input voltage • Synchronize with Cooper-Wheelock SM, DSM or a power supply with built-in Cooper-Wheelock sync protocol • Field selectable taps for 25 or 70 VRMS operation from 1/8 watt up to 2 watts • High efficiency design for maximum output at minimum wattage across a frequency range of 400 to 4000 HZ • Fast installation with IN/OUT screw terminals using #12 to #18 AWG wires Listings Listings and approvals below apply to the basic E Series Low Profile Speakers and Speaker Strobes. In some cases, certain modules may not be listed by certain approval agencies, or listing may be in process. Consult factory for latest listing status. • UL Listed: files S2652 (Speakers), S2652/ S5391 (Strobe/Speakers) • MEA Listed. file 151-92-E Vol. XXI • CSFM approved: files 7320-0785:134, (Speakers), 7125-0785:146 (Strobes/Speakers), 7125-0785:152 General Notes • Strobes are designed to flash once per second minimum over their “Regulated Voltage Range”. Note that NFPA-72 specifies a flash rate of 1 to 2 flashes per second and ADA Guidelines specify a flash rate of 1 to 3 flashes per second. • All candela ratings represent min. effective Strobe intensity per UL Standard 1971. • Series E Speaker Strobes and Series E Speakers are listed under UL Standard 1971 for indoor use with a temperature range of 32°F to 120°F (0°C to 49°C) and maximum humidity of 85%. • “Regulated Voltage Range” is the newest terminology used by UL to identify voltage range. Prior to this change, UL used the term, “Listed Voltage Range”. WARNING: CONTACT COOPER-WHEELOCK FOR THE CURRENT “INSTALLATION INSTRUCTIONS” AND “GENERAL INFORMATION” SHEET (P82380) ON THESE PRODUCTS. THESE DOCUMENTS UNDERGO PERIODIC CHANGES. IT IS IMPORTANT THAT YOU HAVE CURRENT INFORMATION ON THESE PRODUCTS. THESE MATERIALS CONTAIN IMPORTANT INFORMATION THAT SHOULD BE READ PRIOR TO SPECIFYING OR INSTALLING THESE PRODUCTS, INCLUDING: Engineer’s Specifications • TOTAL CURRENT REQUIRED BY ALL APPLIANCES CONNECTED TO SYSTEM SECONDARY POWER SOURCES. • FUSE RATINGS ON NOTIFICATION APPLIANCE CIRCUITS TO HANDLE PEAK CURRENTS FROM ALL APPLIANCES ON THOSE CIRCUITS. • COMPOSITE FLASH RATE FROM MULTIPLE STROBES WITHIN A PERSON’S FIELD OF VIEW. • ADDING, REPLACING OR CHANGING APPLIANCES OR CHANGING CANDELA SETTINGS WILL AFFECT CURRENT DRAW. RECALCULATE CURRENT DRAW TO ENSURE THAT THE TOTAL AVERAGE CURRENT AND TOTAL PEAK REQUIRED BY ALL APPLIANCES DO NOT EXCEED THE RATED CAPACITY OF THE POWER SOURCES OR FUSES. • THE VOLTAGE APPLIED TO THESE PRODUCTS MUST BE WITHIN THEIR “REGULATED VOLTAGE RANGE”. • INSTALLATION OF 110 CANDELA STROBE PRODUCTS IN SLEEPING AREAS. • INSTALLATION IN OFFICE AREAS AND OTHER SPECIFICATION AND INSTALLATION ISSUES. • USE STROBES ONLY ON CIRCUITS WITH CONTINUOUSLY APPLIED OPERATING VOLTAGE. DO NOT USE STROBES ON CODED OR INTERRUPTED CIRCUITS IN WHICH THE APPLIED VOLTAGE IS CYCLED ON AND OFF AS THE STROBES MAY NOT FLASH. • FAILURE TO COMPLY WITH THE INSTALLATION INSTRUCTIONS OR GENERAL INFORMATION SHEETS COULD RESULT IN IMPROPER INSTALLATION, APPLICATION, AND/OR OPERATION OF THESE PRODUCTS IN AN EMERGENCY SITUATION, WHICH COULD RESULT IN PROPERTY DAMAGE AND SERIOUS INJURY OR DEATH TO YOU AND/OR OTHERS. • CONDUCTOR SIZE (AWG), LENGTH AND AMPACITY SHOULD BE TAKEN INTO CONSIDERATION PRIOR TO DESIGN AND INSTALLATION OF THESE PRODUCTS, PARTICULARLY IN RETROFIT INSTALLATIONS. The speaker appliances shall be Cooper-Wheelock Series E Speakers and speaker strobe appliances shall be Cooper-Wheelock Series E Speaker Strobes or approved equals. The speakers shall be UL Listed under Standard 1480 for Fire Protective Service and speakers equipped with strobes shall be listed under UL Standard 1971 for Signaling Devices for the Hearing-Impaired. In addition, the strobes shall be certified to meet the requirements of FCC Part 15, Class B. All speakers shall be designed for a field selectable input of either 25 or 70 VRMS, with selectable power taps from 1/8 watt to 2 watts. All models shall have listed sound output of up to 87 dB at 10 feet and a listed frequency response of 400 to 4000 Hz. The speaker shall also incorporate a sealed back construction. All inputs shall employ terminals that accept #12 to #18 AWG wire sizes. The strobe portion of the appliance shall produce a flash rate of one (1) flash per second over the Regulated Voltage Range and shall incorporate a Xenon flashtube enclosed in a rugged Lexan® lens. The strobe shall be of low current design. Where, Multi-Candela Speaker Strobes are specified, the strobe intensity has field selectable settings and shall be rated per UL Standard 1971 at 15/30/75/110cd or 135/185cd for wall mount and 15/30/75/95cd or 115/177cd for ceiling mount. The selector switch for selecting the candela shall be tamper resistant. The 15/75 candela strobe shall be specified when 15 candela UL Standard 1971 listing with 75 candela on-axis is required (ADA compliance). When synchronization is required, the strobe portion of the appliance shall be compatible with Cooper-Wheelock’s SM, DSM sync modules or the power supply with built-in Patented Cooper-Wheelock Sync Protocol. The strobes shall not drift out of synchronization at any time during operation. If the sync module or Power Supply fails to operate, (i.e., contacts remain closed), the strobe shall revert to a nonThe speaker and speaker strobe appliances shall be designed for indoor surface or flush mounting. The speaker and speaker strobe shall incorporate a speaker mounting plate with a grille cover which is secured with two screws for a level, aesthetic finish and shall mount to standard electrical hardware requiring no additional trimplate or adapter. The finish of the Series E speakers and speaker strobes shall be white, red or nickel plate. All speakers and speaker strobe appliances shall be backward compatible. Cooper-Wheelock products must be used within their published specifications and must be PROPERLY specified, applied, installed, operated, maintained and operationally tested in accordance with their installation instructions at the time of installation and at least twice a year or more often and in accordance with local, state and federal codes, regulations and laws. Specification, application, installation, operation, maintenance and testing must be performed by qualified personnel for proper operation in accordance with all of the latest National Fire Protection Association (NFPA), Underwriters’ Laboratories (UL), National Electrical Code (NEC), Occupational Safety and Health Administration (OSHA), local, state, county, province, district, federal and other applicable building and fire standards, guidelines, regulations, laws and codes including, but not limited to, all appendices and amendments and the requirements of the local authority having jurisdiction (AHJ). E Low Profile Speakers & Strobes CS-2242 09/01/06 Page 2 of 4 FROM PRECEDING APPLIANCE OR VOICE EVACUATION PANEL + Wiring Diagram SERIES E SPEAKER & STROBE OPERATE INDEPENDENTLY (NON-SYNC OR SYNC) + - + - FROM PRECEDING STROBE, SYNC MODULE, POWER SUPPLY OR FACP NEXT +TO STROBE OR - EOLR +- +- STROBE SPEAKER Audible NAC Cir. Strobe NAC Cir. SERIES E SPEAKER STROBES SYNCHRONIZED WITH MULTIPLE DSM MODULES Note: Figure shows interconnection to strobe through sync module. Speaker portion requires 2 separate conductors to FACP. F A C P TO NEXT APPLIANCE OR EOLR Audible NAC Cir. DSM #1 Sync + - E E E E E DSM #2 Strobe NAC Cir. Sync Audible NAC Cir. DSM #3 + Sync Strobe NAC Cir. E + - DSM Interconnecting wiring shown. Maximum of twenty (20) STROBE NAC CIRCUIT OUT DSM SYNC + - +OUT 1 + IN 1 SERIES E SPEAKER STROBE APPLIANCES SYNCHRONIZED WITH DSM MODULE SINGLE CLASS “A” E E E E + AUDIBLE MINUS 2 + IN 2 CS-2242 09/01/06 E MINUS 1 FACP STROBE NAC CIRCUIT RETURN E Low Profile Speakers & Strobes E + OUT 2 Page 3 of 4 NOTE: All CAUTIONS and WARNINGS are identified by the symbol . All warnings are printed in bold capital letters. PLEASE READ THESE SPECIFICATIONS AND ASSOCIATED INSTALLATION INSTRUCTIONS CAREFULLY BEFORE USING, SPECIFYING OR APPLYING THIS PRODUCT. FAILURE TO COMPLY WITH ANY OF THESE INSTRUCTIONS, CAUTIONS OR WARNINGS COULD RESULT IN IMPROPER APPLICATION, INSTALLATION AND/OR OPERATION OF THESE PRODUCTS IN AN EMERGENCY SITUATION, WHICH COULD RESULT IN PROPERTY DAMAGE, AND SERIOUS INJURY OR DEATH TO YOU AND/OR OTHERS. S Y N C M O D E LS / P O W E R S UP P LY M OD EL N UM B E R IN P U T V O LT A G E (VD C ) A VER A GE M EA N C UR R E N T @ 24 VD C M O U N T IN G O P T IO N S SM -12/ 24-R 24 .028 W D SM -12/24-R 24 .035 W SM Sync Module is rated for 3.0 amperes @ 24 VDC. DSM Sync Module is rated for 3.0 amperes per circuit. The maximum number of interconnected DSM modules is twenty (20). Refer to Data Sheet S3000 or Installation Instructions P83123 for SM and P83177 for DSM. Ordering Information S T RO BE C A NDEL A NO NS Y NC E7 0 - 2 4 MCW - FR 1 5 /3 0 /7 5 /1 1 0 X X E7 0 - 2 4 MCW - FW 1 5 /3 0 /7 5 /1 1 0 X X M O DEL E7 0 - 2 4 1 5 7 5 W - FR S Y NC M O DEL W /S M , C O L O R WALL/ C EIL ING M O UNT ING O P T IO NS *** UL A G ENC Y A P P RO V A L S M EA C S FM FM BFP Re d W a ll L ,O ,P,Q ,U,Y X X X * X W h ite W a ll L ,O ,P,Q ,U,Y X X X * X 1 5 ( 7 5 o n A x is ) X X Re d W a ll L ,O ,P,Q ,U,Y X X X * X E7 0 - R - - - Re d W a ll/Ce ilin g Q ,V X X X * X E7 0 - W - - - W h ite W a ll/Ce ilin g Q ,V X X X * X * E7 0 - 2 4 MCW H- FR 1 3 5 /1 8 5 X X Re d W a ll L ,O ,P,Q ,U,Y X * * * E7 0 - 2 4 MCW H- FW 1 3 5 /1 8 5 X X W h ite W a ll L ,O ,P,Q ,U,Y X * * * * 1 5 /3 0 /7 5 /9 5 X X W h ite Ce ilin g Q ,V X * X * * E9 0 - W - - - W h ite W a ll/Ce ilin g Q ,V X X X * X E9 0 - R - - - Re d W a ll/Ce ilin g Q ,V X X X * X 1 1 5 /1 7 7 X X W h ite Ce ilin g Q ,V X * * * * E9 0 - 2 4 MCC- FW E9 0 - 2 4 MCCH- FW T A BL E 1: A V ERA GE RM S C URRENT * E70/E90 SPEA KER ST ROBES 16 v dc 24 v dc 33 v dc E70 ST ROBE C URRENT - WA L L M OUNT 241575W 15/75c d 0.101 0.064 0.047 24M C W 15c d 0.062 0.041 0.032 30c d 0.102 0.065 0.047 75c d 0.192 0.116 0.081 E90 ST ROBE C URRENT - C EIL ING M OUNT 24M C WH 110c d 0.265 0.155 0.107 135c d 0.300 0.195 0.145 24M C C 185c d 0.420 0.270 0.190 15c d 0.068 0.045 0.035 30c d 0.112 0.072 0.052 24M C C H 75c d 0.211 0.128 0.089 95c d 0.292 0.171 0.118 115c d 0.300 0.195 0.145 177c d 0.420 0.270 0.190 * Average RMS Current is per UL average RMS method and Average Mean Current is per UL average mean method. For rate In Rush and Peak current across the UL Listed voltage range for both filtered DC and unfiltered VRMS (FWR), see installation instructions. ** Refer to mounting options data sheet. TABLE 2: E70/E90 UL REVERBERANT dBA @ 10 Feet** w atts Gamewell-FCI 12 Clintonville Road Northford, CT 06472-1610 Phone: 203-484-7161 Fax: 203-484-7118 www.gamewell-fci.com A Honeywell Company © 2006 Gamewell-FCI 1/8 1/4 1/2 1 2 E Speaker 78.1 80.8 83.8 86.0 88.8 E Speaker Strobe 77.5 80.4 83.2 85.7 87.8 ** dBA ratings based on UL testing under UL Standard 1480 Specifications and wiring information are provided for information only and are believed to be accurate. Gamewell-FCI assumes no responsibility for their use. Data and design are subject to change without notice. Installation and wiring instructions shipped with the product shall always be used for actual installation. For more information, contact Gamewell-FCI. Page 4 of 4 E Low Profile Speakers & Strobes CS-2242 09/01/06