HOPERF HB4404DSIP5D

Approved by:
Checked by:
Issued by:
SPECIFICATION
PRODUCT: SAW FILTER
MODEL:
HB4404D (X6941D)
SIP5D
HOPE MICROELECTRONICS CO.,LIMITED
Tel:+86-755-82973806
Fax:+86-755-82973550
E-mail: [email protected] http://www.hoperf.com
Page 1 of 1
1.Construction
1.1 Dimension and materials
Type : B4404D
1.2. Circuit construction, measurement circuit
2.Characteristics
Standard atmospheric conditions
Unless otherwise specified , the standard rang of atmospheric conditions for making
measurements and tests is as follows;
Ambient temperature : 15℃ to 35℃
Relative humidity
: 25% to 85%
Air pressure
: 86kPa to 106kPa
1
Operating temperature rang
Operating temperature rang is the rang of ambient temperatures in which the filter
can be
operated continuously. -10℃ ~ +60℃
Storage temperature rang
Storage temperature rang is the rang of ambient temperatures at which the filter can
be stored
without damage.
Conditions are as specified elsewhere in these specifications. -40℃ ~ +70℃
Reference temperature
+25℃
2.1 Maximum Rating
DC voltage
VDC
12
V
Between any terminals
AC voltage
Vpp
10
V
Between any terminals
2.2 Electrical Characteristics
Source impedance
Zs=50Ω
Load impedance
ZL=2kΩ//3pF and matching network TA=25℃
Item
Freq
min
typ
max
Center frequency
Fo
44.00
MHz
Insertion attenuation
44.00MHz
17.7
19.7
21.7
dB
Reference level
Amplitude ripple (p-p)
0.5
dB
41.60 ... 46.40 MHz
40.75MHz
25.0
32.0
-
dB
41.31MHz
0.6
1.6
2.6
dB
41.43MHz
-0.9
0.3
1.5
dB
41.60MHz
-0.7
0.1
0.8
dB
46.40MHz
-0.7
0.1
0.8
dB
46.57MHz
46.69MHz
47.25MHz
35.00~39.10MHz
39.10~40.35MHz
Sidelobe
47.65~48.65MHz
48.65~55.00MHz
Temperature coefficient
-0.7
0.8
25.0
32.0
26.0
24.0
30.0
0.6
2.0
36.0
40.0
32.0
30.0
37.0
-18
1.5
3.2
-
dB
dB
dB
dB
dB
dB
dB
ppm/k
Relative attenuation
2
2.3 Environmental Performance Characteristics
Item Test condition
Allowable change of absolute
Level at center frequency(dB)
High temperature test
< 1.0
70℃ 1000H
Low temperature test
< 1.0
-40℃ 1000H
Humidity test
< 1.0
40℃ 90-95% 1000H
Thermal shock
< 1.0
-20℃==25℃==80℃ 20 cycle
30M
10M
30M
Solder temperature test
< 1.0
Sold temp.260℃ for 10 sec.
Soldering
More then 95% of total
Immerse the pins melt solder
area of the pins should
be covered with solder
at 260℃+5/-0℃ for 5 sec.
2.4 Mechanical Test
Item
Test condition
Vibration test
600-3300rpm amplitude 1.5mm
3 directions 2 H each
Drop test
On maple plate from 1 m high 3 times
Lead pull test
Pull with 1 kg force for 30 seconds
Lead bend test
90o bending with 500g weigh 2 times
2.5 Voltage Discharge Test
Item
Test condition
Surge test
Between any two electrode
Allowable change of absolute
Level at center frequency(dB)
<1.0
<1.0
<1.0
<1.0
Allowable change of absolute
Level at center frequency(dB)
<1.0
3