HFX6015-xxx Fiber Optic LAN Components 660nm LED For Industrial Bus Systems FEATURES • Super bright LED for optical fiber communication • High accuracy by use of special plastic package with centered LED chip • High output at suitable peak wavelength (typ.) for plastic fiber • High frequency cut-off, most suited for high speed data transmissions (fc = typ. 7 MHz) HFX6015-200 only • Metal barrel for high mechanical stability • Separate grounding of barrel for optimum EMI/RFI shielding SERCOS HFX6015-210 (Fig.1) and HFX6015-200 Parameter Coupled Power (Fig.2) Test Conditions Symbol Min IF = 50mA *, 1mm fibre PC 700 Test Conditions Symbol Min PC –5.5 Test Conditions Symbol Min IF = 50mA *, 1mm fibre PC 300 Typ Max Units 1400 µW Max Units Note: Available for all products with date code 03.05 or later PROFIBUS HFX6015-4xx Parameter Coupled Power 1mm fibre Typ dbm GENERAL PURPOSE BUS APPLICATIONS Parameter Coupled Power Typ Note: * Derate Linearly from 25°C: 0.93mA/°C DC current Other receptacles available. For additional information see please “Mounted LEDs/Transmitters” Sensing and Control Max Units µW Fiber Optic LAN Components 660nm LED For Industrial Bus Systems Sensing and Control HFX6015-xxx Fiber Optic LAN Components HFX6015-xxx 660nm LED For Industrial Bus Systems ABSOLUTE MAXIMUM RATINGS (25° C free air temperature unless otherwise noted) Forward current....................................................................70mA Peak forward current.....................(1ms pulse, 1/20 duty) 300mA Reverse voltage.......................................................................+4V Power dissipation...............................................................140mW Operating temperature..........................................– 30°C to +85°C Storage temperature.......................................... – 30°C to +100°C Lead soldering time at 260°C................5 sec (3,0 mm from body) ELECTRO OPTICAL CHARACTERISTICS Parameter Test Conditions Peak Wavelength IF = 30mA * Symbol λP Min Typ 660 Spectral Line Half Width IF = 30mA * ∆λ 30 Forward Voltage IF = 30mA * VF 2.0 Reverse Current VR = 4V IR Capacitance IF = 30mA * Response Time Max Units nm nm 2.5 100 V µA Co 50 pF tr , tf 50 ns Note: * Derate Linearly from 25°C: 0.93mA/°C DC current WARRANTY / REMEDY Honeywell warrants goods of its manufacture as being free of defective material and faulty workmanship. Contact your local sales office for warranty information. If warranted goods are returned to Honeywell during that period of coverage, Honeywell will repair or replace without charge those items it finds defective. The foregoing is Buyer’s sole remedy and is in lieu of all other warranties, expressed or implied, including those of merchantability and fitness for a particular purpose. While we provide application assistance, personally, through our literature and the Honeywell web site, it is up to the customer to determine the suitability of the product in the application. Specifications may change at any time without notice. The information we supply is believed to be accurate and reliable as of this printing. However, we assume no responsibility for its use. SALES AND SERVICE Honeywell serves its customers through a worldwide network of sales offices and distributors. For application assistance, current specifications, pricing or name of the nearest Authorized Distributor, contact a nearby sales office or call: TELEPHONE Germany UK USA & Canada International INTERNET http://www.honeywell.com/sensing/ e-mail: info.sc @ honeywell.com © Honeywell 2005. All rights reserved. Sensing and Control Honeywell GmbH Stuttgarter Straße 5 D-80807 Munich Germany 02/05 + 49-89-35 81 33 10 + 44-1698-481 481 1-800-367-6945 1-815-235-6847 www.honeywell.com/sensing