marlow industries a global leader in thermoelectric solutions Subsidiary of II-VI Incorporated Thermoelectric Cooler SP1507 Performance Values Hot Side Temperature (°C) 27°C 50°C Δ Tmax (°C-dry N2): 64 72 Qmax (watts): 5.4 6.2 Imax (amps): 1.8 1.8 Vmax (vdc): 4.7 5.4 AC Resistance (ohms): 2.30 --- Mechanical Characteristics .158 [4.00] Thru Hole Red, Positive Lead Leads: 28 AWG (0.40) TFE Insulated Stranded Tinned Copper .564 .444 [14.33] [11.28] Blk, Negative Lead 3.00 ±.25 [76.20 ±6.35] .444 [11.28] +.004 -.008 [2.43 ±0.13] .096 .002 [0.05] Cold Side A .001 [0.03] .001 [0.03] Ceramic Material: Alumina (AC) Millimeters are in [ ] Ordering Options Model Number SP1507-03AC Description No exterior metallization A Features • • • 214-340-4900 (tel) ● 214-341-5212 (fax) ● www.marlow.com Pretinned metallized ceramic surface(s) with 96°C or 117°C solder. Thermistor mounted on edge of cold side ceramic. (Calibration available.) Elevated temperature burn-in with test data provided. Doc # 102-0018 Rev F Page 1 of 2 marlow industries a global leader in thermoelectric solutions Subsidiary of II-VI Incorporated Performance Curves Environment: One atmosphere dry nitrogen Hot Side Temperature: 27°C HEAT LOAD (WATTS) T (C) 60.0 40.0 20.0 0.0 5.0 4.0 3.0 2.0 Q=0 T=0 1.0 0.0 0.0 0.4 0.8 1.2 1.6 CURRENT (AMPS) 2.0 0.00 0.50 1.00 1.50 2.00 2.50 3.00 3.50 4.00 4.50 5.00 5.50 60.0 T (C) 0.00 0.50 1.00 1.50 2.00 2.50 3.00 3.50 4.00 4.50 5.00 HEAT LOAD (WATTS) 80.0 40.0 20.0 0.0 VOLTAGE (VDC) 80.0 VOLTAGE (VDC) Hot Side Temperature: 50°C 5.0 4.0 3.0 2.0 Q=0 T=0 1.0 0.0 0.0 0.4 0.8 1.2 1.6 CURRENT (AMPS) 2.0 For performance information in a vacuum or with hot side temperatures other than 27°C or 50°C, consult one of our Applications Engineers. Installation Recommended mounting methods: Bonding with thermal epoxy or soldering with metallized ceramics. For additional information, please refer to our TEC Installation Guide. Operation Cautions For maximum reliability, storage and operation below 85°C in a non-condensing environment is recommended. To minimize thermal stress, use linear/proportional temperature control or a similar method rather than an ON/OFF method. Addresses Marlow Industries, Inc. 10451 Vista Park Road Dallas Texas 75238-1645 214-340-4900 (tel) 214-341-5212 (fax) II-VI Japan Inc. WBG Marive East 17F 2-6 Nakase, Mihama-ku Chiba-Shi, Chiba 261-7117 Japan 81 43 297 2693 (tel) 81 43 297 3003 (fax) [email protected] www.ii-vi.co.jp Marlow Industries Europe Aberdeen House, South Road Haywards Heath West Sussex RH164NG UK +44 (0)1444-443404 (tel) +44 (0)1444-443334(fax) II-VI Singapore Pte., Ltd. Blk. 5012, Techplace II #04-07 & 05-07/12, Ang Mo Kio Ave. 5 Singapore 569876 (65) 6481 8215 (tel) (65) 6481 8702 (fax) [email protected] www.ii-vi.com.sg 214-340-4900 (tel) ● 214-341-5212 (fax) ● www.marlow.com Marlow Industries China, II-VI Technologies Beijing A subsidiary of II-VI Incorporated Rm 202, 1# Lize 2nd Middle Road Wangjing, Chaoyang District Beijing 100102 China 64391260 ext 105 (tel) 64399315 (fax) [email protected] Doc # 102-0018 Rev F Page 2 of 2