Performance Values
Hot Side Temperature (°C)
27°C
50°C
64
72
Qmax (watts):
0.90
1.0
Imax (amps):
1.8
1.8
Vmax (vdc):
0.8
0.9
AC Resistance (ohms):
0.40
---
Δ Tmax (°C-dry N2):
Mechanical Characteristics
P o s itiv e L e a d
.1 5 6
[3 .9 6 ]
L e a d s : 2 8 A W G (0 .3 2 ) B u s
S o lid T in n e d C o p p e r
N e g a tiv e L e a d
2 .0 0 + /- .2 5
[5 0 .8 0 + /-6 .3 5 ]
.1 5 6
[3 .9 6 ]
C o ld S id e
.0 0 3 [0 .0 8 ]
A
.0 0 1 [0 .0 3 ]
.0 8 5 + /-.0 0 5
[2 .1 5 + /-0 .1 3 ]
.0 0 1 [0 .0 3 ]
C e ra m ic M a te ria l: A lu m in a
M illim
(A
C ) e te rs a re in [ ]
A
Ordering Options
Features
Model Number
Description
•
•
NL1020T-01
both surfaces are metallized
NL1020T-02
hot side exterior is metallized
NL1020T-03
no metallization
Available Modifications
•
•
•
214-340-4900 (tel) ● 214-341-5212 (fax) ● www.marlow.com
RoHS 2002/95/EC compliant
For example, and NL1020T with only the hot side
metallized is specified as an NL1020T-02AC
Pretinned metallized ceramic surface(s) with 117°C
solder.
Thermistor mounted on edge of cold side ceramic.
(Calibration available.)
Elevated temperature burn-in with test data
provided.
Doc # 102-0294
Rev B
Page 1 of 2
marlow
industries
a global leader in thermoelectric solutions
Subsidiary of II-VI Incorporated
Performance Curves
Environment: One atmosphere dry nitrogen
Hot Side Temperature: 27°C
HEAT
LOAD
(WATTS)
0.00
0.10
0.20
0.30
0.40
0.50
0.60
0.70
0.80
0.90
60.0
40.0
20.0
0.0
HEAT
LOAD
(WATTS)
80.0
0.00
0.10
0.20
0.30
0.40
0.50
0.60
0.70
0.80
0.90
1.00
60.0
T (C)
80.0
T (C)
Hot Side Temperature: 50°C
40.0
20.0
0.6
0.4
Q=0
T=0
0.2
0.0
0.0
0.4
0.8
1.2
1.6
CURRENT (AMPS)
2.0
VOLTAGE (VDC)
VOLTAGE (VDC)
0.0
0.8
1.0
0.8
0.6
0.4
0.2
0.0
0.0
0.4
0.8
1.2
1.6
CURRENT (AMPS)
2.0
Q=0
T=0
For performance information in a vacuum or with hot side temperatures other than 27°C or 50°C, consult one of our Applications
Engineers.
Installation
Recommended mounting methods: Bonding with thermal epoxy or soldering with metallized ceramics. For
additional information, please refer to our TEC Installation Guide.
Operation Cautions
For maximum reliability, storage and operation below 85°C in a non-condensing environment is
recommended. To minimize thermal stress, use linear/proportional temperature control or a similar method
rather than an ON/OFF method.
Addresses
Marlow Industries, Inc.
10451 Vista Park Road
Dallas Texas 75238-1645
214-340-4900 (tel)
214-341-5212 (fax)
II-VI Japan Inc.
WBG Marive East 17F
2-6 Nakase, Mihama-ku
Chiba-Shi, Chiba 261-7117
Japan
81 43 297 2693 (tel)
81 43 297 3003 (fax)
[email protected]
www.ii-vi.co.jp
Marlow Industries Europe
Aberdeen House, South Road
Haywards Heath
West Sussex RH164NG UK
+44 (0)1444-443404 (tel)
+44 (0)1444-443334(fax)
II-VI Singapore Pte., Ltd.
Blk. 5012, Techplace II
#04-07 & 05-07/12, Ang Mo Kio Ave. 5
Singapore 569876
(65) 6481 8215 (tel)
(65) 6481 8702 (fax)
[email protected]
www.ii-vi.com.sg
214-340-4900 (tel) ● 214-341-5212 (fax) ● www.marlow.com
Marlow Industries China, II-VI
Technologies Beijing
A subsidiary of II-VI Incorporated
Rm 202, 1# Lize 2nd Middle Road
Wangjing, Chaoyang District
Beijing 100102 China
64391260 ext 105 (tel)
64399315 (fax)
[email protected]
Doc # 102-0294
Rev B