MINIATURE HIGH POWER RELAY
Features
• 30A
File No.:E134517
switching capabilities
• 2.5KV
dielectric coil to contacts
• Heavy
• Class
load up to 7,200VA
B, Class F insulation available
File No.:CH0023315-2002A
COIL
CONTACT DATA
Contact
Arrangement
Initial Contact
Resistance
1A
1B
1C (NO)
1C (NC)
50m (at 1A 24VDC)
Contact Material
General Purpose Power Relays JQX-105F-4
Max. Switching
Capacity
Max. Switching
Voltage
Max. Switching
Current
AgCdO
JQX-105F-4
Rating
277VAC/28VDC
30A
15A
30A 28VDC
20A
10A
20A 277VAC 10A 277VAC
15A 277VAC
20A 28VDC
Pick-up
Voltage
VDC
Drop-out
Voltage
VDC
Coil
Resistance
5
3.75
0.5
27
10%
6
4.50
0.6
40
10%
10A 240VAC
20A 28VDC
10A 28VDC
25A 240VAC 15A 240VAC 20A 240VAC
10A 240VAC
20A 28VDC
10A 28VDC
10A 28VDC
20A 28VDC
10A 28VDC
1 x 107 OPS
1 x 105 OPS
Dielectric Between coil and Contacts
Strength Between open contacts
1000M , 500VDC
1500VAC 1min.
15ms
Release time (at nomi. Volt.)
Class B
Ambient temperature
Class F
Shock Resistance
Vibration Resistance
9
6.75
0.9
97
10%
12
9.00
1.2
155
10%
15
11.25
1.5
256
10%
18
13.50
1.8
380
10%
24
18.00
2.4
660
10%
48
36.00
4.8
2560
10%
70
52.50
7.0
5500
10%
110
82.50
11
13450
10%
Nominal
Voltage
VAC
Pick-up
Voltage
VAC
Drop-out
Voltage
VAC
2500VAC 1min.
Operate time (at nomi. Volt.)
10ms
DC:-55
AC:-55
DC:-55
AC:-55
Functional
Destructive
Coil
Resistance
to 85
to 60
12
9.6
2.4
25
10%
to 105
to 85
24
19.2
4.8
100
10%
120
96.0
24.0
2500
10%
208
166.4
41
11000
10%
220/240
192
48
13490
10%
277
220
54
15000
10%
98 m/s2
980 m/s2
DA: 1.5mm, 10 to 55Hz
98%, +40
PCB & QC
Approx. 36g
Sealed & Dust Cover
HONGFA RELAY
ISO9001/QS9000/ISO14000 CERTIFIED
114
Nominal
Voltage
VDC
1HP 250VAC 1/2HP 125VAC
Initial Insulation Resistance
Construction
COIL DATA
10A 28VDC
CHARACTERISTICS
Unit weight
See table below
1HP 125VAC
Mechanical life
Electrical life
Termination
Coil Resistance
12 to 277VAC
2HP 250VAC 1/4HP 250VAC
20A 28VDC
Humidity
5 to 110VDC
2HP 250VAC
30A 240VAC 15A 240VAC 20A 240VAC
JQX-105F-4L
Rating
Coil Voltage
AC:2VA
7200VA/560W 3600VA/280W 4800VA/560W 2400VA/280W
30A 277VAC
UL/CUR rating
DC:0.9W
Coil power
Note:When require pick-up voltage < 80% of nominal voltage, special order allowed.
ORDERING INFORMATION
JQX-105F-4 / 018
Type
D
K
1H
S
F
JQX-105F-4: 30A JQX-105-4L: 25A
Coil voltage
Coil Input
DC:5 to 110VDC AC:12 to 277VAC
D: DC A: AC
Coil terminal width K: 4.8mm
Nil: 2.8mm
Contact arrangement 1H:1A(SPST-NO) 1D:1B(SPST-NC) 1Z:1C(SPDT)
Structure
S: Sealed
Nil: Cover
Insulation Standard
F: Class F
Nil: Class B
OUTLINE DIMENSIONS, WIRING DIAGRAM AND PC BOARD LAYOUT
Outline Dimensions
Wiring Diagram
General Purpose Power Relays JQX-105F-4
3-0.8
3-6.4
2-0.5
JQX-105F-4/ - - - 2.8mm Coil terminal width
2-2.8
3-0.8
3-6.4
2-0.5
JQX-105F-4/ - -K- - 4.8mm Coil terminal width
2-4.8
CHARACTERISTICS CURVE
COIL TEMPERATURE RISE
MAXIMUM SWITCHING POWER
100
100
30
20
Temperature(
)
Contact Current (A)
120
90
80
30A
70
10
FORM A
FORM C NO
FORM B
FORM C NC
AC LOAD
DC LOAD
1
60
0A
0
80
90
100
110
120
130
140
150
Percentage Of Nominal Coil Voltage
160
170
180
10
100 300
1000
Contact Voltage (V)