JQX-105F-4 MINIATURE HIGH POWER RELAY Features • 30A File No.:E134517 switching capabilities • 2.5KV dielectric coil to contacts • Heavy • Class load up to 7,200VA B, Class F insulation available File No.:CH0023315-2002A COIL CONTACT DATA Contact Arrangement Initial Contact Resistance 1A 1B 1C (NO) 1C (NC) 50m (at 1A 24VDC) Contact Material General Purpose Power Relays JQX-105F-4 Max. Switching Capacity Max. Switching Voltage Max. Switching Current AgCdO JQX-105F-4 Rating 277VAC/28VDC 30A 15A 30A 28VDC 20A 10A 20A 277VAC 10A 277VAC 15A 277VAC 20A 28VDC Pick-up Voltage VDC Drop-out Voltage VDC Coil Resistance 5 3.75 0.5 27 10% 6 4.50 0.6 40 10% 10A 240VAC 20A 28VDC 10A 28VDC 25A 240VAC 15A 240VAC 20A 240VAC 10A 240VAC 20A 28VDC 10A 28VDC 10A 28VDC 20A 28VDC 10A 28VDC 1 x 107 OPS 1 x 105 OPS Dielectric Between coil and Contacts Strength Between open contacts 1000M , 500VDC 1500VAC 1min. 15ms Release time (at nomi. Volt.) Class B Ambient temperature Class F Shock Resistance Vibration Resistance 9 6.75 0.9 97 10% 12 9.00 1.2 155 10% 15 11.25 1.5 256 10% 18 13.50 1.8 380 10% 24 18.00 2.4 660 10% 48 36.00 4.8 2560 10% 70 52.50 7.0 5500 10% 110 82.50 11 13450 10% Nominal Voltage VAC Pick-up Voltage VAC Drop-out Voltage VAC 2500VAC 1min. Operate time (at nomi. Volt.) 10ms DC:-55 AC:-55 DC:-55 AC:-55 Functional Destructive Coil Resistance to 85 to 60 12 9.6 2.4 25 10% to 105 to 85 24 19.2 4.8 100 10% 120 96.0 24.0 2500 10% 208 166.4 41 11000 10% 220/240 192 48 13490 10% 277 220 54 15000 10% 98 m/s2 980 m/s2 DA: 1.5mm, 10 to 55Hz 98%, +40 PCB & QC Approx. 36g Sealed & Dust Cover HONGFA RELAY ISO9001/QS9000/ISO14000 CERTIFIED 114 Nominal Voltage VDC 1HP 250VAC 1/2HP 125VAC Initial Insulation Resistance Construction COIL DATA 10A 28VDC CHARACTERISTICS Unit weight See table below 1HP 125VAC Mechanical life Electrical life Termination Coil Resistance 12 to 277VAC 2HP 250VAC 1/4HP 250VAC 20A 28VDC Humidity 5 to 110VDC 2HP 250VAC 30A 240VAC 15A 240VAC 20A 240VAC JQX-105F-4L Rating Coil Voltage AC:2VA 7200VA/560W 3600VA/280W 4800VA/560W 2400VA/280W 30A 277VAC UL/CUR rating DC:0.9W Coil power Note:When require pick-up voltage < 80% of nominal voltage, special order allowed. ORDERING INFORMATION JQX-105F-4 / 018 Type D K 1H S F JQX-105F-4: 30A JQX-105-4L: 25A Coil voltage Coil Input DC:5 to 110VDC AC:12 to 277VAC D: DC A: AC Coil terminal width K: 4.8mm Nil: 2.8mm Contact arrangement 1H:1A(SPST-NO) 1D:1B(SPST-NC) 1Z:1C(SPDT) Structure S: Sealed Nil: Cover Insulation Standard F: Class F Nil: Class B OUTLINE DIMENSIONS, WIRING DIAGRAM AND PC BOARD LAYOUT Outline Dimensions Wiring Diagram General Purpose Power Relays JQX-105F-4 3-0.8 3-6.4 2-0.5 JQX-105F-4/ - - - 2.8mm Coil terminal width 2-2.8 3-0.8 3-6.4 2-0.5 JQX-105F-4/ - -K- - 4.8mm Coil terminal width 2-4.8 CHARACTERISTICS CURVE COIL TEMPERATURE RISE MAXIMUM SWITCHING POWER 100 100 30 20 Temperature( ) Contact Current (A) 120 90 80 30A 70 10 FORM A FORM C NO FORM B FORM C NC AC LOAD DC LOAD 1 60 0A 0 80 90 100 110 120 130 140 150 Percentage Of Nominal Coil Voltage 160 170 180 10 100 300 1000 Contact Voltage (V) 115