FF-1170-20 This filter is intended to provide very good insertion loss and transient potection. Mechanically the filter is Intended to operate in severe temperature and vibration environments. This filter can be used in transportation vehicles such as buses, trucks, and trains. Operating Voltage = 100 VDC Operating Current (Max) = 20 Amp @ 50oC 15 Amp @ 70oC Temperature Range = -40 TO 50o C Diel. Withstand (Line - Case)= 1500 VAC For 1 Min Transient Protection = 130 VDC Nominal Transient Clamp = 123 - 137 VDC Leakage Current = NIL Discharge Volt. After 1 Sec= 31 Volts Max. Order Part number: FF-1170-20 USA JMK Inc 15 Caldwell Dr. Amherst, NH 03031 EUR JMK Inc Glasgow G13 1DN Scotland UK PH: 603 886-4100 FX: 603 886-4115 email: [email protected] PH: 44-(0) 7785310729 Fax: 44-(0) 141 589 1884