LIGITEK LG2040-HV12-O-W54

LIGITEK ELECTRONICS CO.,LTD.
Property of Ligitek Only
HIGH VOLTAGE LED LAMPS
Pb
Lead-Free Parts
LG2040/HV12-O-W54
DATA SHEET
DOC. NO : QW0905-LG2040/HV12-O-W54
REV.
:
A
DATE
:
26 - Dec. - 2006
LIGITEK ELECTRONICS CO.,LTD.
Property of Ligitek Only
LG2040/HV12-O-W54
Package Dimension
3.0
4.0
4.2
5.2
Page 1/2
Directivity Radiation
+Vcc
0°
Vcc=12Volts
□0.5
TYP
IF
17.0±0.5
-30 °
RL=1200ohms ±20%
RL
25.0MIN
-60 °
78.0±2.0
VF
Pyrocondensation Cannula
30 °
60°
IF= Vcc-VF
RL
100% 75% 50%
25%
0
25% 50% 75% 100%
3.0
+
-
Note:1.All dimension are in millimeter tolerance is ±0.25mm unless otherwise noted
2.Specifications are subject to change without notice
•Part Selection And Application Information (Ratings At 25℃ Ambient)
PART NO
MATERIAL
COLOR
Emitted
LG2040/HV12-O-W54 GaP
Green
Peak
wave
length
λPnm
Spectral
halfwidth
△λnm
Lens
Green Diffused
565
30
Forward
current
(mA)
@12V
Luminous
lntensity
(mcd)
@12V
Reverse
current
(μA)
VR=15V
Min. Max. Min. Typ.
Max.
6.0
100
12
8.0
20
Viewing
angle
2θ1/2
(deg)
36
•Absolute Maximum Rating (Ta=25℃)
GREEN
UNIT
PARAMETER
G
Forward voltage
12
V
Reverse voltage
15
V
Operating Temperature
Storage Temperature
-40℃ TO +85℃
-40℃ TO +100 ℃
Lead Soldering Temperature 260℃ For 5 Seconds(2.0mm From Body)
REMARK
LIGITEK ELECTRONICS CO.,LTD.
Property of Ligitek Only
Page 2/2
PART NO. LG2040/HV12-O-W54
Reliability Test:
Test Item
Test Condition
Description
Reference
Standard
Operating Life Test
1.Under Room Temperature
2.If=20mA
3.t=1000 hrs (-24hrs, +72hrs)
This test is conducted for the purpose
of detemining the resistance of a part
in electrical and themal stressed.
MIL-STD-750: 1026
MIL-STD-883: 1005
JIS C 7021: B-1
High Temperature
Storage Test
1.Ta=105 ℃±5℃
2.t=1000 hrs (-24hrs, +72hrs)
The purpose of this is the resistance of
the device which is laid under condition
of high temperature for hours.
MIL-STD-883:1008
JIS C 7021: B-10
Low Temperature
Storage Test
1.Ta=-40 ℃±5℃
2.t=1000 hrs (-24hrs, +72hrs)
The purpose of this is the resistance
of the device which is laid under
condition of low temperature for hours.
High Temperature
High Humidity Test
1.Ta=65 ℃±5℃
2.RH=90 %~95%
3.t=240hrs ±2hrs
The purpose of this test is the resistance
of the device under tropical for hours.
Thermal Shock Test
1.Ta=105 ℃±5℃ &-40 ℃±5 ℃
(10min) (10min)
2.total 10 cycles
The purpose of this is the resistance of
the device to sudden extreme changes
in high and low temperature.
MIL-STD-202: 107D
MIL-STD-750: 1051
MIL-STD-883: 1011
Solder Resistance
Test
1.T.Sol=260 ℃±5℃
2.Dwell time= 10 ±1sec.
This test intended to determine the
thermal characteristic resistance
of the device to sudden exposures
at extreme changes in temperature
when soldering the lead wire.
MIL-STD-202: 210A
MIL-STD-750: 2031
JIS C 7021: A-1
Solderability Test
1.T.Sol=230 ℃±5℃
2.Dwell time=5 ±1sec
This test intended to see soldering well
performed or not.
MIL-STD-202: 208D
MIL-STD-750: 2026
MIL-STD-883: 2003
JIS C 7021: A-2
JIS C 7021: B-12
MIL-STD-202:103B
JIS C 7021: B-11