NAUTILUX Ceiling surface mount L U M I N IS NT100C . NT110C . NT125C Specification All exposed cast aluminum components are made of non corrosive pure aluminum copper free (Aluminum is less than .1% copper content.#356 alloy.) Finish: All polyester powder baked coatings preceded with a 5 baths preparation process. Meets military grade MIL-C781706 with a 2000 hours salt spray test. 1 - Pulse rated medium base porcelain socket. - 75W/600V thermoplastic compact fluorescent socket. - One-piece molded silicone gasket with memory retention. - High power factor CWA ballast. Or 98% P.F.electronic smart ballast with end of life detection for compact fluorescent. - All stainless steel hardware. - All Moving and removable parts are sealed with a memory retention silicone gasket. 2 1- Closed cast aluminum housing. 2- Semi-specular aluminum reflector, with vertical lamp position to provide uniform light on the diffuser. (Side lamp mount for H100 source.) 3 3- Borosilicate frosted glass diffuser with internal concentric reinforcement prismatic pattern. 4 4- Selection of two glass ring and glass shield. NT100C: One piece cast aluminum cross cage. NT110C: Full glass lens with cast aluminum retainer ring. NT125C: One piece heavy cast aluminum star cage. Photometry Cross view NT100C NT110C NT125C 9 1/2” Separate updated technical sheets with related Plane view specification models and light sources with I.E.S formatted photometry are available on 90 www.luminis.com. 60 9 1/2” Certification Mounting Max. Max. weight: 19 lbs. Installation: Mounts over a standard 4” octagonal electrical box with 3 1/2” c/c mounting holes. UL. Wet Location. Model# Light source selection MH (ED17) M50 NT100C NT110C NT125C 30 HPS (ED17) H50 INC. (A19) A100 CF (Gx24q) Single lamp F118 F126 F132 F142 120 V Standard factory prewired (If no voltage is specified) For other voltages, please specify with catalog number. H.I.D. 208 V 240 V 277 V 347 V Note: 50W.HPS is available with 120/277V only. CF (Gx24q) Two lamps (Lamps by others) Voltage F218 F226 F232 COMP. FLUO. Smart ballast 120/277 347 V (To specify) For options details and specifications, please refer to page 72 Finish (Refer to color chart) Standard selection WHT:Snow white BKT: Jet black BZT: Bronze GRT: Titanium gray DGT: Gun metal CHT: Champagne MST: Matte silver GNT: Forest green Optional colors CS: Custom color RAL: RAL# color Options Accessories Polycarbonate lens diffuser. (Max.50W) Surface mount connection box. PC1: SWK: EM42S: FS: QS: QRS: Electrical 1 lamp (26/32/42W) Fuse Standby lamp socket. H.I.D. lamp restrike Note: EM optional battery test switch and pilot lamp are remotely installed. Luminaires may be altered for design improvements or discontinued without prior notice. LUMINIS [ USA ] - 3555 NW 53rd Court, Fort Lauderdale, FL.33309 LUMINIS [ Canada ] - 87 C Brunswick D.D.O. Q.C. Canada H9B 2J5 Tel: 954 .717 .4155 Fax: 954 . 717.4157 Toll free: 888 .401 .6999 Page 57 Web: www.luminis.com Sept. 2006 Rev. Feb.2007 L U M IN I S NAUTILUX OPTIONAL ACCESSORIES General notes: Please specify selected option as a suffix to the specified model number. ex:NT100-M100-WHT-PC1 Each model is provided with a listing of compatible options.Some options may not be compatible when used in the same luminaire. This information is indicated when it is applicable. Square lens Diffuser. Surface connection box Option: PC6 High impact acrylic lens diffuser. Max: 50W Quartz lamp restrike Option: QRS Quartz restrike standby lamp kit max.100w DC bayonet type White translucent round diffuser. Option: SWK Alternate regressed reflector. Option: PC1 Option: R2 Polycarbonate lens diffuser Max: 50W 1 1/2" deep luminaire matching connection box for surface conduit feed. (2) 7/8" dia. K.O. @ 180 deg. Ceiling surface mounting White translucent round diffuser. Option: C Satin anodized corrugated reflector surface. White translucent oblong diffuser. Option: PC2 Option: PCO In line fuse Option: FS 3 Amps. in line protection fuse, factory installed with the pole or inside fixture when pole is not required. Light photo sensor Option: PH1 -120V PH2 - 208/277V Photo electric sensor, factory installed with the pole or inside fixture when pole is not required. s ens 0W) Emergency battery back-up . One lamp: l 2W) 26w: 450 Lmns.. 32w: 575 Lmns. 42w: 750 Lmns. o cell ocket. rike Time: 90 Mnts -120/277V / T 0º C Ceiling surface mount conversion kit. Maximum wattage 2x32w compact fluorescent. (factory installed.) High impact acrylic lens diffuser. Max: 50W Polycarbonate lens diffuser Max: 50W Emergency line quartz lamp Option: QS Quartz lamp socket for separate emergency line. Max.100w DC bayonet type EM42 wiring EM42 / EM42S Note: EM42S wiring HOT BLK WHT EM Ballast wiring diagram for 120V factory connection. WHT AC ballast EM42 option is supplied with integral test switch and pilot light. EM ballast EM42S is supplied with additional wiring for external remotely installed test switch and pilot light. Black/120V (Factory wired) Orange/277V (Cap unused lead.) COM For 57w & 70w: (Remote installation only) Consult factory Please refer to luminaire specification sheet option listing. Single pole test switch (Breaking the connection) Luminaires may be altered for design improvements or discontinued without prior notice. LUMINIS [ USA ] - 3555 NW 53rd Court, Fort Lauderdale, FL.33309 LUMINIS [ Canada ] - 87 C Brunswick D.D.O. Q.C. Canada H9B 2J5 Tel: 954 .717 .4155 Fax: 954 . 717.4157 Toll free: 888 .401 .6999 Page 72 Web: www.luminis.com Sept. 2006 Rev. Feb.2008