LUMINIS NT125C

NAUTILUX
Ceiling surface mount
L U M I N IS
NT100C . NT110C . NT125C
Specification
All exposed cast aluminum components are made of non corrosive
pure aluminum copper free (Aluminum is less than .1% copper
content.#356 alloy.)
Finish: All polyester powder baked coatings preceded with
a 5 baths preparation process. Meets military grade
MIL-C781706 with a 2000 hours salt spray test.
1
- Pulse rated medium base porcelain socket.
- 75W/600V thermoplastic compact fluorescent socket.
- One-piece molded silicone gasket with memory retention.
- High power factor CWA ballast. Or 98% P.F.electronic smart
ballast with end of life detection for compact fluorescent.
- All stainless steel hardware.
- All Moving and removable parts are sealed with a
memory retention silicone gasket.
2
1- Closed cast aluminum housing.
2- Semi-specular aluminum reflector, with vertical lamp position
to provide uniform light on the diffuser.
(Side lamp mount for H100 source.)
3
3- Borosilicate frosted glass diffuser with internal concentric
reinforcement prismatic pattern.
4
4- Selection of two glass ring and glass shield.
NT100C: One piece cast aluminum cross cage.
NT110C: Full glass lens with cast aluminum retainer ring.
NT125C: One piece heavy cast aluminum star cage.
Photometry
Cross view
NT100C
NT110C
NT125C
9 1/2”
Separate updated technical
sheets with related
Plane view specification
models and light sources with
I.E.S formatted photometry are
available on
90 www.luminis.com.
60
9 1/2”
Certification
Mounting
Max. Max. weight: 19 lbs. Installation: Mounts over a standard
4” octagonal electrical box with 3 1/2” c/c mounting holes.
UL. Wet Location.
Model#
Light source selection
MH (ED17)
M50
NT100C
NT110C
NT125C
30
HPS (ED17)
H50
INC. (A19)
A100
CF (Gx24q)
Single lamp
F118
F126
F132
F142
120 V Standard factory
prewired
(If no voltage is specified)
For other voltages, please
specify with catalog number.
H.I.D.
208 V
240 V
277 V
347 V
Note: 50W.HPS
is available with
120/277V only.
CF (Gx24q)
Two lamps
(Lamps by others)
Voltage
F218
F226
F232
COMP. FLUO.
Smart ballast 120/277
347 V (To specify)
For options details and specifications,
please refer to page 72
Finish
(Refer to color chart)
Standard selection
WHT:Snow white
BKT: Jet black
BZT: Bronze
GRT: Titanium gray
DGT: Gun metal
CHT: Champagne
MST: Matte silver
GNT: Forest green
Optional colors
CS: Custom color
RAL: RAL# color
Options
Accessories
Polycarbonate lens
diffuser. (Max.50W)
Surface mount
connection box.
PC1:
SWK:
EM42S:
FS:
QS:
QRS:
Electrical
1 lamp (26/32/42W)
Fuse
Standby lamp socket.
H.I.D. lamp restrike
Note: EM optional battery
test switch and pilot lamp are
remotely installed.
Luminaires may be altered for design improvements or discontinued without prior notice.
LUMINIS [ USA ] - 3555 NW 53rd Court, Fort Lauderdale, FL.33309
LUMINIS [ Canada ] - 87 C Brunswick D.D.O. Q.C. Canada H9B 2J5
Tel: 954 .717 .4155 Fax: 954 . 717.4157
Toll free: 888 .401 .6999
Page 57
Web: www.luminis.com
Sept. 2006 Rev. Feb.2007
L U M IN I S
NAUTILUX
OPTIONAL ACCESSORIES
General notes:
Please specify selected option as a suffix to the specified model number. ex:NT100-M100-WHT-PC1
Each model is provided with a listing of compatible options.Some options may not be compatible
when used in the same luminaire. This information is indicated when it is applicable.
Square lens Diffuser.
Surface connection box
Option: PC6
High impact acrylic lens diffuser.
Max: 50W
Quartz lamp restrike
Option: QRS
Quartz restrike
standby lamp kit
max.100w DC
bayonet type
White translucent round
diffuser.
Option: SWK
Alternate regressed
reflector.
Option: PC1
Option: R2
Polycarbonate
lens diffuser
Max: 50W
1 1/2" deep luminaire matching
connection box for surface conduit
feed. (2) 7/8" dia. K.O. @ 180 deg.
Ceiling surface mounting
White translucent round
diffuser.
Option: C
Satin anodized
corrugated
reflector
surface.
White translucent oblong
diffuser.
Option: PC2
Option: PCO
In line fuse
Option: FS
3 Amps. in line protection fuse,
factory installed with the pole
or inside fixture when pole is
not required.
Light photo sensor
Option: PH1 -120V
PH2 - 208/277V
Photo electric sensor,
factory installed with the pole
or inside fixture when pole is
not required.
s
ens
0W)
Emergency battery back-up
.
One lamp:
l
2W)
26w: 450 Lmns..
32w: 575 Lmns.
42w: 750 Lmns.
o cell
ocket.
rike
Time: 90 Mnts -120/277V / T 0º C
Ceiling surface mount conversion kit.
Maximum wattage 2x32w compact
fluorescent. (factory installed.)
High impact acrylic lens diffuser.
Max: 50W
Polycarbonate
lens diffuser
Max: 50W
Emergency line quartz lamp
Option: QS
Quartz lamp socket for
separate emergency
line. Max.100w DC
bayonet type
EM42 wiring
EM42 / EM42S
Note:
EM42S wiring
HOT
BLK
WHT
EM Ballast wiring
diagram for 120V
factory connection.
WHT
AC ballast
EM42 option is supplied
with integral test switch and
pilot light.
EM
ballast
EM42S is supplied with
additional wiring for
external remotely installed
test switch and pilot light.
Black/120V (Factory wired)
Orange/277V
(Cap unused lead.)
COM
For 57w & 70w:
(Remote installation only) Consult factory
Please refer to luminaire
specification sheet option
listing.
Single pole test switch (Breaking the connection)
Luminaires may be altered for design improvements or discontinued without prior notice.
LUMINIS [ USA ] - 3555 NW 53rd Court, Fort Lauderdale, FL.33309
LUMINIS [ Canada ] - 87 C Brunswick D.D.O. Q.C. Canada H9B 2J5
Tel: 954 .717 .4155 Fax: 954 . 717.4157
Toll free: 888 .401 .6999
Page 72