© MARL INTERNATIONAL LTD 2001 : DS 11/01 Issue 3
Fax: +44 (0)1229 585155
ISO 9001 : 1994 APPROVED
• email: [email protected] • website: www.marl.co.uk • website: www.marl-leds.com • Telephone +44 (0)1229 582430
NEW PRODUCT DATA
Signalling Panel & Console
Filament Replacement
LED Technology
Fit and Forget LED
Signalling Panel Indicators
•
•
•
MTBF: 100, 000 Hours (11 Years)
Reliable: Flicker-free & shock resistant
Railtrack Approved
LEDs:- offer greatly extended life and
reliability in comparison to filament
bulbs, in addition to reduced heat
generation and power consumption.
They are readily available in all the main
signal and status defined colours and
base styles, for immediate retro-fit.
LEDs
FILAMENT REPLACEMENT LEDs - T6.8SB Bi-Polar
•
•
•
•
•
•
Direct replacement
for T6.8 SB
Resistant to shock
and vibration
Bi-Polar: ac/dc
operation
Massive
reductions in
maintenance costs
Railtrack
Approved ^
Flat-topped
version available
for increased
viewing angle
238 SERIES
Pack Size = 20
Dimensions in mm (Typical)
Not to Scale
Ordering Information & Typical Technical Characteristics (Ta = 15 - 25°C)
Mean Time Between Failure = 100,000 Hours. Luminous intensity figures refer to the unmodified discrete LED.
PART NUMBER
COLOUR
LENS
VOLTAGE
AC/DC
Vopr
CURRENT
lopr
LUMINOUS
INTENSITY
Iv@20mA
WAVE
LENGTH
λp
VIEWING
ANGLE
OPERATING
TEMP
Topr
STORAGE
TEMP
Tstg
Narrow
-20 ~ +50
-30 ~ +80
oC
oC
STANDARD INTENSITY
HIGH INTENSITY
238-501-98
Red
24
17
2750
660
238-521-98
Yellow
24
17
4500
590
238-532-98
Green
24
16
6000
525
238-930-98
Blue
24
16
2000
470
238-997-98
White
24
16
3000
*
238-501-93
Red
28
17
2750
660
238-521-93
Yellow
28
17
4500
590
238-532-93
Green
28
16
6000
525
238-930-93
Blue
28
16
2000
470
238-997-93
White
28
16
3000
*
Vdc
mA
mcd
nm
Water Clear
UNITS
* = Typical emission colour: x = 0.31, y = 0.32. Colour temperature 8000K.
Intensities (Iv) and colour shades of white (x,y co-ordinates) may vary between LEDs within a batch.
^ Railtrack Approval: PA05/697
SAMPLES AVAILABLE
Fax: +44 (0)1229 585155
•
email: [email protected]
•
website: www.marl.co.uk
•
website: www.marl-leds.com
• Telephone +44 (0)1229 582430
TECHNICAL INFORMATION
OVERVIEW
Product Description
Filament replacement LEDs have been available for many years, and there has been a transition from the use of multi-LED products to the use of high
performance, high reliability single LED products. Marl has always been at the forefront of designing and manufacturing LED indicators for harsh and difficult
environments with demanding performance expectations. The new 238 series LED lamp replacement allows the user to exchange the standard tungsten
filament bulb to BS1050 or black-tip as it is sometimes known, with a high brightness low current consumption cool, reliable alternative. This follows extensive
trials by Railtrack on Westinghouse M3 and M5 signalling panels and consoles. Internal circuitry specifically designed for rail applications allows for operation
at either AC or DC voltages allowing polarity free replacement, and while also providing the benefit of not producing a distracting flicker, like some lower
specification LED replacement devices when used on AC voltage supplies.
With an MTBF of 100,000 hours, routine maintenance costs are minimised and overall system reliability and safety enhanced.
Samples and technical support are now available upon request.
MATERIALS
Contacts
Extension Sleeve
LED Lens
Nickel Plated Brass
Acetal
Water Clear Epoxy
APPLICATIONS
Replacement tungsten filament bulbs with the approved Marl 238 series eliminates maintenance costs and improves signal indication recognition by the
signaller, improving safety. This is due to the cool running of the LED, which does not deteriorate the panel filter, obscuring visibility, while also the enhanced
brightness and colour definition of the LEDs also increases this recognition. When used on a console within operator buttons, again the low heat generation
does not cause the button to become brittle, eliminating the possibility of a fracture. Signallers also can now operate buttons that are cool to the touch,
compared with tungsten bulbs. The trials have clearly shown that for white signal indications, the use of yellow LEDs provides the best visual performance
compared to true white LEDs.
Marl provide the full range of approved colours for use within signalling panels and consoles for rail use. The 238 series forms part of a family of bulb
replacements available from Marl.
INTENSITY
The small physical size of an LED chip means that it can be
regarded as a point source to a very good approximation. The
light output of an LED is therefore expressed in terms of
luminous intensity, which is defined as the flux, in lumens (lm),
emitted per unit solid angle in steradians (sr). The SI unit of
luminous intensity is the candela (cd).
RELATED DOCUMENTS
These products are designed and manufactured in the UK to
International Quality Standard BS EN ISO9001 : 1994.
Telephone +44 (0)1229 582430 •
Fax: +44 (0)1229 585155
•
email: [email protected]
•
website: www.marl.co.uk
•
website: www.marl-leds.com