LED Industrial Lighting - Filament Replacement LEDs MY REQUIREMENTS Faxback for notes and your requirements for the 238 Series: Quantity Required: Colour: Voltage: My Reference: Delivery Required: My Name: Company Name: Contact Telephone / Email: If you would like a quotation for the above requirements, please photocopy this sheet and fax it back to Marl International on: FAX: 01229 585155 for a prompt reply © MARL INTERNATIONAL LTD 2001 : DS 11/01 Issue 3 Fax: +44 (0)1229 585155 ISO 9001 : 1994 APPROVED • email: [email protected] • website: www.marl.co.uk • website: www.marl-leds.com • Telephone +44 (0)1229 582430 NEW PRODUCT DATA Signalling Panel & Console Filament Replacement LED Technology Fit and Forget LED Signalling Panel Indicators • • • MTBF: 100, 000 Hours (11 Years) Reliable: Flicker-free & shock resistant Railtrack Approved LEDs:- offer greatly extended life and reliability in comparison to filament bulbs, in addition to reduced heat generation and power consumption. They are readily available in all the main signal and status defined colours and base styles, for immediate retro-fit. LEDs FILAMENT REPLACEMENT LEDs - T6.8SB Bi-Polar • • • • • • Direct replacement for T6.8 SB Resistant to shock and vibration Bi-Polar: ac/dc operation Massive reductions in maintenance costs Railtrack Approved ^ Flat-topped version available for increased viewing angle 238 SERIES Pack Size = 20 Dimensions in mm (Typical) Not to Scale Ordering Information & Typical Technical Characteristics (Ta = 15 - 25°C) Mean Time Between Failure = 100,000 Hours. Luminous intensity figures refer to the unmodified discrete LED. PART NUMBER COLOUR LENS VOLTAGE AC/DC Vopr CURRENT lopr LUMINOUS INTENSITY Iv@20mA WAVE LENGTH λp VIEWING ANGLE OPERATING TEMP Topr STORAGE TEMP Tstg Narrow -20 ~ +50 -30 ~ +80 oC oC STANDARD INTENSITY HIGH INTENSITY 238-501-98 Red 24 17 2750 660 238-521-98 Yellow 24 17 4500 590 238-532-98 Green 24 16 6000 525 238-930-98 Blue 24 16 2000 470 238-997-98 White 24 16 3000 * 238-501-93 Red 28 17 2750 660 238-521-93 Yellow 28 17 4500 590 238-532-93 Green 28 16 6000 525 238-930-93 Blue 28 16 2000 470 238-997-93 White 28 16 3000 * Vdc mA mcd nm Water Clear UNITS * = Typical emission colour: x = 0.31, y = 0.32. Colour temperature 8000K. Intensities (Iv) and colour shades of white (x,y co-ordinates) may vary between LEDs within a batch. ^ Railtrack Approval: PA05/697 SAMPLES AVAILABLE Fax: +44 (0)1229 585155 • email: [email protected] • website: www.marl.co.uk • website: www.marl-leds.com • Telephone +44 (0)1229 582430 TECHNICAL INFORMATION OVERVIEW Product Description Filament replacement LEDs have been available for many years, and there has been a transition from the use of multi-LED products to the use of high performance, high reliability single LED products. Marl has always been at the forefront of designing and manufacturing LED indicators for harsh and difficult environments with demanding performance expectations. The new 238 series LED lamp replacement allows the user to exchange the standard tungsten filament bulb to BS1050 or black-tip as it is sometimes known, with a high brightness low current consumption cool, reliable alternative. This follows extensive trials by Railtrack on Westinghouse M3 and M5 signalling panels and consoles. Internal circuitry specifically designed for rail applications allows for operation at either AC or DC voltages allowing polarity free replacement, and while also providing the benefit of not producing a distracting flicker, like some lower specification LED replacement devices when used on AC voltage supplies. With an MTBF of 100,000 hours, routine maintenance costs are minimised and overall system reliability and safety enhanced. Samples and technical support are now available upon request. MATERIALS Contacts Extension Sleeve LED Lens Nickel Plated Brass Acetal Water Clear Epoxy APPLICATIONS Replacement tungsten filament bulbs with the approved Marl 238 series eliminates maintenance costs and improves signal indication recognition by the signaller, improving safety. This is due to the cool running of the LED, which does not deteriorate the panel filter, obscuring visibility, while also the enhanced brightness and colour definition of the LEDs also increases this recognition. When used on a console within operator buttons, again the low heat generation does not cause the button to become brittle, eliminating the possibility of a fracture. Signallers also can now operate buttons that are cool to the touch, compared with tungsten bulbs. The trials have clearly shown that for white signal indications, the use of yellow LEDs provides the best visual performance compared to true white LEDs. Marl provide the full range of approved colours for use within signalling panels and consoles for rail use. The 238 series forms part of a family of bulb replacements available from Marl. INTENSITY The small physical size of an LED chip means that it can be regarded as a point source to a very good approximation. The light output of an LED is therefore expressed in terms of luminous intensity, which is defined as the flux, in lumens (lm), emitted per unit solid angle in steradians (sr). The SI unit of luminous intensity is the candela (cd). RELATED DOCUMENTS These products are designed and manufactured in the UK to International Quality Standard BS EN ISO9001 : 1994. Telephone +44 (0)1229 582430 • Fax: +44 (0)1229 585155 • email: [email protected] • website: www.marl.co.uk • website: www.marl-leds.com