R LBTV Self-regulating heating cables Electrical freeze protection for long pipelines in both nonhazardous and hazardous (classified) locations The LBTV self-regulating heating cables provide freeze protection and low-temperature maintenance for longline applications. The LBTV heating cables maintain process temperatures up to 150°F (65°C) and can withstand intermittent exposure to temperatures up to 185°F (85°C). The cables are configured for use in nonhazardous and hazardous (classified) locations, including areas where corrosives may be present. The LBTV heating cables provide long circuit length capability. They can be used for continuous circuit lengths up to 1125 feet powered from a single source. LBTV cables are especially well suited for tracing long pipelines containing temperature-sensitive fluids or where high reliability is required. Raychem® LBTV cables meet the requirements of the U.S. National Electrical Code and the Canadian Electrical Code. For additional information, contact your Tyco Thermal Controls representative or call Tyco Thermal Controls at (800) 545-6258. Heating cable construction Fluoropolymer outer jacket (-CT) Tinned-copper braid Modified polyolefin inner jacket Self-regulating conductive core Nickel-plated copper bus wire (10 AWG) Application Area classification Traced surface type Chemical resistance Supply voltage Nonhazardous and hazardous (classified) locations Metal and plastics Organic and aqueous inorganic chemicals and corrosives 200–277 Vac Temperature rating Maximum maintain or continuous exposure temperature (power on) Maximum intermittent exposure temperature, 1000 hours (power on or off) 150°F (65°C) 185°F (85°C) Temperature ID number (T-rating) T6, 185°F (85°C) Temperature ID numbers are consistent with North America national electrical codes. Approvals Hazardous Locations Class I, Div. 2, Groups A, B, C, D Class II, Div. 2, Groups F, G Class III Zone Approvals CLI, ZN1, AEx e II Class I, Div. 1 and 2, Groups A, B, C, D Class II, Div. 1 and 2, Groups E, F, G Class III Class I, Div. 2, Groups A, B, C, D Class II, Div. 2, Groups F, G Design and installation For proper design and installation, use TraceCalc® Pro software or the Design section of the Industrial Product Selection and Design Guide. Literature is available through the Tyco Thermal Controls Fax-on-Demand system and via the Tyco Thermal Controls Web site, www.tycothermal.com. H52424 (800) 545-6258 01/02 www.tycothermal.com Tyco Thermal Controls 1 of 2 LBTV Nominal power output rating on metal pipes Adjustment factors Power output Circuit length 0.93 0.88 1.08 1.11 208 V 277 V 10 LBTV2-CT 8 W/ft 6 To choose the correct heating cable for your application, use the Design section of the Industrial Product Selection and Design Guide. For more detailed information, use TraceCalc Pro design software. 4 2 0 30 (–1) 40 (4) 50 (10) 60 (15) 70 80 90 100 (21) (27) (32) (38) Pipe temperature 110 (43) 120 (49) 130 (54) 140 (60) 150 °F (65) (°C) Maximum circuit lengths based on circuit-breaker sizes Ambient temperature at start-up 40°F 20°F 0°F –20°F –40°F LBTV2-CT Maximum continuous circuit length (in feet) per circuit breaker 240 V 15 A 20 A 30 A 40 A 50 A 60 A 70 A 305 410 630 875 1125 1125 1125 250 335 510 700 915 1125 1125 210 280 425 585 755 955 1125 180 240 365 500 645 810 995 160 210 320 440 560 700 855 Note: Tyco Thermal Controls and national electrical codes require both ground-fault protection of equipment and a grounded metallic covering on all heating cables. Following are some of the ground-fault breakers that satisfy this equipment protection requirement: Square D Type QOB-EPD or QO-EPD; Raychem/Square D Type GFPD EHB-EPD (277 Vac); Cutler Hammer (Westinghouse) Type QBGFEP. Product characteristics Minimum bend radius Weight (lb per 10 ft, nominal) Bus wire size Outer jacket color Heating cable dimensions Components LBTV2-CT @68˚F (20˚C): 1/2 in (12.7 mm) 1.7 10 AWG Black 0.705 x 0.330 in These components must be used to ensure proper functioning of the product and compliance with warranty, code, and approvals requirements. JBM-100-LBTV2 Power connection/splice H52424 01/02 (800) 545-6258 www.tycothermal.com E-100-LBTV2 End seal Tyco Thermal Controls 2 of 2