MEANWELL RID-50A

RID-50
50W Dual Output Switching Power Supply
series
Features :
Isolated output & GND for CH1,CH2
Universal AC input / Full range
Protections: Short circuit / Overload / Over voltage
Cooling by free air convection
LED indicator for power on
100% full load burn-in test
All using 105
long life electrolytic capacitors
Withstand 300VAC surge input for 5 second
High operating temperature up to 70
Withstand 5G vibration test
High efficiency, long life and high reliability
3 years warranty
SPECIFICATION
MODEL
OUTPUT
INPUT
RID-50A
RID-50B
OUTPUT NUMBER
CH1
CH2
CH1
DC VOLTAGE
5V
12V
5V
CH2
24V
RATED CURRENT
6A
2A
4A
1.4A
CURRENT RANGE
0.3 ~ 6A
0.3 ~ 3A
0.3 ~ 6A
0.2 ~ 2A
RATED POWER
54W
53.6W
RIPPLE & NOISE (max.) Note.2 80mVp-p
120mVp-p
VOLTAGE ADJ. RANGE
CH1: 4.75 ~ 5.5V
VOLTAGE TOLERANCE Note.3 2.0%
8.0%
80mVp-p
150mVp-p
CH1: 4.75 ~ 5.5V
2.0%
+8,-4%
LINE REGULATION
Note.4
0.5%
1.5%
0.5%
1.5%
LOAD REGULATION
Note.5
0.5%
5.0%
0.5%
5.0%
SETUP, RISE TIME
500ms, 20ms/230VAC
HOLD UP TIME (Typ.)
60ms/230VAC
VOLTAGE RANGE
88 ~ 264VAC
FREQUENCY RANGE
47 ~ 63Hz
EFFICIENCY (Typ.)
80%
AC CURRENT (Typ.)
INRUSH CURRENT (Typ.)
1.3A/115VAC
0.8A/230VAC
COLD START 33A/230VAC
LEAKAGE CURRENT
1200ms, 30ms/115VAC at full load
14ms/115VAC at full load
125 ~ 373VDC (Withstand 300VAC surge for 5sec. Without damage)
81%
<2mA / 240VAC
110 ~ 150% rated output power
OVERLOAD
PROTECTION
OVER VOLTAGE
WORKING TEMP.
WORKING HUMIDITY
ENVIRONMENT STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
SAFETY STANDARDS
WITHSTAND VOLTAGE
SAFETY & ISOLATION RESISTANCE
EMC
(Note 6)
HARMONIC CURRENT
DIMENSION
PACKING
NOTE
Protection type : Hiccup mode, recovers automatically after fault condition is removed
-25 ~ +70
(Refer to output load derating curve)
20 ~ 90% RH non-condensing
-40 ~ +85 , 10 ~ 95% RH
0.03%/ (0 ~ 50 )on +5V output
10 ~ 500Hz, 5G 10min./1cycle, period for 60min. each along X, Y, Z axes
UL60950-1, TUV EN60950-1 approved
I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC
I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25
EMI CONDUCTION & RADIATION Compliance to EN55022 (CISPR22) Class B
EMS IMMUNITY
MTBF
OTHERS
Protection type : Hiccup mode, recovers automatically after fault condition is removed
CH1: 5.75 ~ 6.75V
/ 70% RH
Compliance to EN61000-3-2,-3
Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204, EN61000-6-2 (EN50082-2), heavy industry level, criteria A
172.6Khrs min. MIL-HDBK-217F (25
99*97*36mm (L*W*H)
0.41Kg; 45pcs/19.5Kg/0.9CUFT
)
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. Line regulation is measured from low line to high line at rated load.
5. Load regulation is measured from 0% to 100% rated load.
6. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets
EMC directives.
File Name:RID-50-SPEC 2008-12-30
RID-50
50W Dual Output Switching Power Supply
Mechanical Specification
2
3.5
51.5
1
9.5
Unit:mm
36
Case No. 905B
series
3
5.5
97
8.2
4
55.5
2-
M
3
5
6
7
20.5
55
3.5
4.5
89
99
6.5
87
74
18
Pin No.
1
2
3
4
36
3
3.5
28
2-M
17.5
7
Terminal Pin No. Assignment
3.5
Assignment
AC/L
AC/N
FG
DC OUTPUT G2
Assignment
Pin No.
DC OUTPUT +V2
5
DC OUTPUT G1
6
DC OUTPUT +V1
7
Block Diagram
fosc : 50KHz
RECTIFIERS
&
FILTER
EMI
FILTER
I/P
POWER
SWITCHING
RECTIFIERS
&
FILTER
+V2
RECTIFIERS
&
FILTER
+V1
COM
DETECTION
CIRCUIT
FG
O.L.P.
CONTROL
O.V.P.
Output Derating VS Input Voltage
Derating Curve
Ta=25
100
100
90
80
80
70
LOAD (%)
LOAD (%)
60
40
20
-25
-25
0
0
10
20
30
40
50
AMBIENT TEMPERATURE ( )
60
70 (VERTICAL)
60
50
40
88
95
100
115
120
140
160
180
200
220
240
264
INPUT VOLTAGE (VAC) 60Hz
File Name:RID-50-SPEC 2008-12-30