MEANWELL SMA01L-05

SMA01
1W DC-DC Unregulated Single Output Converter
series
Features :
1500VDC I/O isolation
3000VDC I/O isolation(optional)
Operating temperature range of -40 ~ +85
Internal SMD technology
Built-in EMI filter
Cooling by free air convection
Non-conductive plastic case
Dual in line package
Industry standard pinout
100% burn-in test
Low cost / High reliability
2 years warranty
SELECTION GUIDE
ORDER NO.
SMA01N-05
SMA01M-05
SMA01L-05
SMA01M-09
SMA01N-09
77%
78%
75%
SMA01L-15
SMA01M-15
SMA01N-15
SMA01L-09
9V
DC OUTPUT VOLTAGE
5V
OUTPUT CURRENT RANGE
0 ~ 200mA
EFFICIENCY(Typ.)
77%
79%
77%
SMA01L-12
SMA01M-12
SMA01N-12
ORDER NO.
without derating
0 ~ 110mA
15V
DC OUTPUT VOLTAGE
12V
OUTPUT CURRENT RANGE
0 ~ 84mA
EFFICIENCY(Typ.)
78%
0 ~ 67mA
80%
78%
79%
79%
77%
21.6 ~ 26.4V
24V
4.5 ~ 5.5V
5V
10.8 ~ 13.2V
12V
21.6 ~ 26.4V
24V
57mA
SPECIFICATION
RATED POWER
OUTPUT
1W
RIPPLE & NOISE (max.) Note.2 100mVp-p
LINE REGULATION
Note.3 1.2% for 1% input variation
LOAD REGULATION
Note.4 8.0%
VOLTAGE ACCURACY
2.0%
SWITCHING FREQUENCY(Typ.) 100KHz
4.5 ~ 5.5V
5V
VOLTAGE RANGE
NORMAL VOLTAGE
Full load 265mA
No load 32mA
110mA
57mA
265mA
110mA
15mA
11mA
32mA
15mA
11mA
PROTECTION (FUSE RECOMMENDED) 500mA
250mA
150mA
500mA
250mA
150mA
INPUT CURRENT
INPUT
10.8 ~ 13.2V
12V
FILTER
Capacitor type
Momentary
OVERLOAD
Protection type : Broken
Momentary
PROTECTION
SHORT CIRCUIT
Protection type : Broken
WORKING TEMP.
-40 ~ +90
WORKING HUMIDITY
20% ~ 90% RH non-condensing
(Refer to output load derating curve)
ENVIRONMENT STORAGE TEMP., HUMIDITY -55 ~ +125 , 10 ~ 95% RH
0.05% / (0 ~ 50 )
TEMP. COEFFICIENT
10 ~ 500Hz, 2G 10min./1 cycle, period for 60min. each along X, Y, Z axes
VIBRATION
WITHSTAND VOLTAGE
I/P-O/P:1.5KVDC
I/P-O/P: 100M Ohms / 500VDC / 25 / 70% RH
ISOLATION RESISTANCE
SAFETY &
80pF max.
ISOLATION CAPACITANCE
EMC
EMI RADIATION
Compliance to EN55022 Class B, FCC part 15 Class B
Compliance to EN61000-4-2,3,4,5,6,8 light industry level, criteria A
EMS IMMUNITY
MTBF
DIMENSION (L*W*H)
700khrs min. MIL-HDBK-217F(25
WEIGHT
1.7g
Mechanical Specification
Unit: mm (inch)
12.7 (0.50)
7.62 (0.30)
10.16 (0.40)
7.1 (0.28)
7.62 (0.30)
SIDE VIEW
)
12.7*10.16*7.1mm or 0.50"*0.40"*0.28" inch for 5V,12V input ; 12.7*10.16*7.62mm or 0.50"*0.40"*0.30" inch for 24V input
1
4
BOTTON
VIEW
7
5
0.25 (0.01)
Derating Curve
Pin Configuration
Pin No.
Output
1
-Vin
4
5
+Vin
+Vout
7
-Vout
100
LOAD (%)
OTHERS
50
5.08 (0.2)
3.81 (0.15)
0.5 (0.02)
-40
NOTE
0
20
40
60
85 90 100
Ta (
)
1.All parameters are specified at normal input, rated load, 25 70% RH ambient.
2.Ripple & noise are measured at 20MHz by using a 12" twisted pair terminated with a 0.1uf & 47uf capacitor.
3.Line regulation is measured from low line to high line at rated load.
4.Load regulation is measured from 20% to 100% rated load.
File Name: SMA01-SPEC 2009-10-12