MIC RL207

AXIAL SILASTIC GUARD JUNCTION STANDARD RECTIFIER
VOLTAGE RANGE
CURRENT
RL201 THRU RL207
FEATURES
•
•
•
•
•
DO-15
Low coat construction
Low forward voltage drop
Low reverse leakage
High forward surge current capability
High temperature soldering guaranteed:
260℃/10 secods/.375”(9.5mm)lead length at 5 lbs(2.3kg) tension
1.0(25.4)
MIN.
.300(7.6)
.230(5.8)
MECHANICAL DATA
•
•
•
•
•
•
.140(3.6)
DIA.
.104(2.6)
Case: Transfer molded plastic
Epoxy: UL94V-O rate flame retardant
Polarity: Color band denotes cathode end
Lead: Plated axial lead, solderable per MIL-STD-202E method 208C
Mounting position: Any
Weight: 0.014 ounce, 0.39 grams
1.0(25.4)
MIN.
.034(0.9)
DIA.
.028(0.7)
Dimensions in inches and (millimeters)
MAXIMUM RATINGS AND ELECTRICAL CHARACTERISTICS
•
•
•
50 to 1000 Volts
2.0 Amperes
Ratings at 25OC ambient temperature unless otherwise specified
Single Phase, half wave, 60Hz, resistive or inductive load
For capacitive load derate current by 20%
RL204 RL205 RL206 RL207
400
600
800
1000
280
420
560
700
400
600
800
1000
Volts
Volts
Volts
I(AV)
2.0
Amps
IFSM
30
Amps
VF
1.0
5.0
50
Volts
IR(AV)
30
µA
CJ
20
pF
Typical Thermal Resistance (Note 2)
RθJA
40
℃/W
Operating Junction Temperature Range
TJ
TSTG
-55 to +150
-55 to +150
℃
SYMBOLS
VRRM
VRMS
VDC
Maximum Repetitive Peak Reverse Voltage
Maximum RMS Voltage
Maximum DC Blocking Voltage
Maximum Average Forward Rectified Current
0.375”(9.5mm) lead length at T A= 50℃
Peak Forward Surge Current
8.3mS single half sine wave superimposed on
rated load (JEDEC method)
Maximum Instantaneous Forward Voltage @2.0A
Maximum DC Reverse Current at Rated
DC Blocking Voltage per element
TA = 25℃
TA = 100℃
Maximum Full Load Reverse Current, full cycle average
0.375”(9.5mm)lead length at TL=75℃
Typical Junction Capacitance (Note 1)
Storage Temperature Range
RL201
50
35
50
RL202
100
70
100
RL203
200
140
200
IR
Notes:
1. Measured at 1.0MHz and Applied Reverse Voltage of 4.0V DC.
2. Thermal Resistance from junction to Ambient at .375”(9.5mm)lead length, P.C.board mounted.
E-mail: [email protected]
Web Site: www.cnmic.com
UNIT
µA
℃
AXIAL SILASTIC GUARD JUNCTION STANDARD RECTIFIER
VOLTAGE RANGE
CURRENT
RL201 THRU RL207
50 to 1000 Volts
2.0 Amperes
RATING AND CHRACTERISTIC CURVES RL201 Thur RL207
FIG.2-MAXIMUM NON-REPETITIVE PEAK
FIG.1-TYPICAL FORWARD CURRENT
DERATING CURVE
FORWARD SURGE CURRENT
70
AVERAGE FORWARD CURRENT,
(A)
2.4
60
1.6
1.2
0.8
Single Phase
Half Wave 60Hz
0.4
Resistive or
50
CURRENT, (A)
PEAK FORW ARD SURGE
2.0
8.3ms Single Half Sine-Wave
(JEDEC Method)T j=Tjmax
40
30
20
10
Inductive Load
0
0
25
100
75
50
150
125
0
175
5
2
1
8
20
10
50
100
NUMBER OF CYCLES AT 60 Hz
AMBIENT TEMPERATURE, (° C)
FIG.3-TYPICAL INSTANTANEOUS
FIG.4-TYPICAL REVERSE
CHARACTERISTICS
FORWARD CHARACTERISTICS
10
0.1
T =25° C
j
Pulse Width=300us
1% Duty Cycle
0.01
0.6
0.8
1.0
1.2
1.4
1.6
1.8
2.0
Tj =100° C
1.0
(mA)
INSTANTANEOUS REVERSE CURRENT,
1
(A)
INSTANTANEOUS FORWARD CURRENT,
10
0.1
Tj =25° C
0.01
0
INSTANTANEOUS FORWARD VOLTAGE,(V)
20
40
60
80
PERCENT OF RATED PEAK
REVERSE VOLTAGE,(%)
FIG.5-TYPICAL JUNCTION CAPACITANCE
CAPACITANCE,(pF)
100
10
TJ=25° C F=1MHz
10
0.1
1.0
4.0
10.0
100
REVERSE VOLTAGE,(VOLTS)
E-mail: [email protected]
Web Site: www.cnmic.com
100
120
140