MORNSUN D120909T-2W

D_T-2W Series
2W, FIXED INPUT, ISOLATED & UNREGULATED
TWIN OUTPUT ULTRAMINIATURE SMD PACKAGE
multi-country patent protection RoHS
FEATURES
PRODUCT PROGRAM
Efficiency up to 85%
Small Footprint
SMD Package
Twin Independent Output
Industry Standard Pinout
No Heat sink Required
1KVDC Isolation
High Power Density
Temperature Range: -40°C to +85°C
No External Component Required
Internal SMD construction
RoHS Compliance
Input
Part
Number
Output
Voltage (VDC)
Efficiency
(%, Typ)
Package
Style
20
82
SMD
12
83
SMD
84
9
84
SMD
67
7
85
SMD
5
200
20
82
SMD
Current (mA)
Voltage
(VDC)
Max
Min
D050505T-2W
5
200
D050909T-2W *
9
112
D051212T-2W *
12
D051515T-2W *
15
D120505T-2W
Nominal
D120909T-2W *
Range
5
4.5-5.5
9
112
12
83
SMD
D121212T-2W *
12
84
9
84
SMD
D121515T-2W *
15
67
7
85
SMD
12
10.8-13.2
APPLICATIONS
The D_T-2W Series are specially designed for
applications where a group of polar power supplies
are isolated from the input power supply in a
distributed power supply system on a circuit board.
Designing.
Note: The D_T-1W series also are available in our company.
These products apply to:
1) Where the voltage of the input power supply is
fixed (voltage variation ≤±10%);
ISOLATION SPECIFICATIONS
Item
2) Where isolation is necessary between input
Isolation voltage
and output (isolation voltage ≤1000VDC);
Isolation resistance
Such as: purely digital circuits, ordinary low
frequency analog circuits and IGBT power device
driven circuits, etc.
Min
Typ
Max
Units
VDC
Tested for 1 minute and 1 mA max(Vo1/Vo2) 1000
3) Where the regulation of the output voltage and
the output ripple and noise are not demanding.
Test condition
Tested for 1 minute and 1 mA max(Vin/Vout) 1000
Isolation
capacitance
Test at 500VDC(Vin/Vout)
1000
Test at 500VDC(Vo1/Vo2)
1000
MΩ
(Vin/Vout)
60
(Vo1/Vo2)
60
pF
OUTPUT SPECIFICATIONS
MODEL SELECTION
D050505T-2W
Item
Test condition
Min
Output power
Rated Power
Package Style
The 2nd Output Voltage
The 1st Output Voltage
Input Voltage
Product Series
Line regulation
Load regulation
Typ
0.2
Max
Units
2
W
±1.2
For Vin change of 1%
10% to 100% full load(5V Output)
12.8
15
10% to 100% full load(9V Output)
8.3
10
10% to 100% full load(12V Output)
6.8
10
10% to 100% full load(15V Output)
6.0
10
%
Output voltage accuracy See tolerance envelope graph
MORNSUN Science & Technology co.,Ltd.
Address: 2th floor 6th building, Huangzhou Industrial
District, Guangzhou, China
Tel: 86-20-38601850
Fax:86-20-38601272
Http://www.mornsun-power.com
MORNSUN reserves the copyright
Temperature drift
100% full load
Ripple & Noise
20MHz Bandwidth
75
Switching frequency
Full load, nominal input
100
0.03
%/°C
150
mVp-p
KHz
Note:
1. All specifications measured at TA=25°C, humidity<75%, nominal input voltage and rated output load
unless otherwise specified.
2. See below recommended circuits for more details.
Specifications subject to change without notice.
D_T-2W
A/0-2008
Page 1 of 2
COMMON SPECIFICATIONS
Item
APPLICATION NOTE
Test Conditions
Min
Typ
Storage humidity
Max
Units
95
%
Operating temperature
-40
85
Storage temperature
-55
125
Temp. rise at full load
15
Lead temperature
1.5mm from case for 10 seconds
DC/DC converter in addition to a maximum load
°C
specified range of input voltage is not exceeded, the
minimum output load is not less than 10% of the full
S
please connect a resistor with proper resistance at the
Plastic (UL94-V0)
3500
Weight
output end in parallel to increase the load, or use our
K hours
2.1
load, and that this product should never be operated
under no load! If the actual output power is very small,
Free air convection
MTBF
(namely full load). During operation, make sure the
260
1
package material
reliably, a minimum load is specified for this kind of
25
Short circuit protection*
Cooling
Requirement On Output Load
To ensure this module can operate efficiently and
g
*Supply voltage must be discontinued at the end of short circuit duration.
company’s products with a lower rated output power
(D_T –1W).
Recommended testing circuit
If you want to further decrease the input/output ripple,
an “LC” filtering network may be connected to the input
TYPICAL CHARECTERISTICS
and output ends of the DC/DC converter, see (Figure1).
L
+Vo1
L
C
Vin
DC DC
C
0V1
+Vo2
L
GND
C
0V2
(Figure 1)
It should also be noted that the inductance and the
frequency of the “LC” filtering network should be
Ambient Temperature ( C )
staggered with the DC/DC frequency to avoid mutual
interference. However, the capacitance of the output
RECOMMENDED REFLOW SOLDERING PROFILE
o
Te mp eratu r e ( C)
1 0 S ec M ax
output, provided the safe and reliable operation is
22 0o C
200
filter capacitor must be proper. If the capacitance is too
big, a startup problem might arise. For every channel of
o
26 0 C
250
ensured, the greatest capacitance of its filter capacitor
sees (Table 1).
150
EXTERNAL CAPACITOR TABLE (TABLE 1)
90 Sec Ma x
( >220 o C )
100
Vin
(VDC)
5
12
-
50
0
Time ( sec . )
OUTLINE DIMENSIONS& RECOMMENDED FOOTPRINT
Cin
(uF)
4.7
2.2
-
Vout
(VDC)
5
9
12
15
Cout
(uF)
4.7
2.2
1
0.74
It’s not recommended to connect any external capacitor in the
application field with less than 0.5 watt output.
6.00
(0.236)
5.75
(0.2 2 6)
First Angle Projection
2.75 (0.10 8)
1.27
(0.05 0)
RECOMMENDED FOOTPRINT
Top view,grid :2.54mm(0 .1inch)
0.25
(0.01 0)
Output Voltage Regulation and Over-voltage
Protection Circuit
The simplest device for output voltage regulation,
over-voltage and over-current protection is a linear
10 9 8
voltage regulator with overheat protection that is
1413 12
12.70( 0.500)
17.78(0.700)
14 13 12
10 9 8
connected to the input or output end in series (Figure2).
Vo1
Vin
REG
0V1
DC
2.0
1 2 3
5 6 7
DC
Vo2
GND
0V2
1 2 3
5 6 7
15.24 (0.600)
17.78 (0.700)
Vo1
REG
1.0
(0.039)
Vin
0V1
DC
DC
Vo2
REG
GND
A
0V2
FOOTPRINT DETAILS
(Figure2)
Function
0.25
A
1.30 0.13
(0.051 0.005 )
0.50 (0.02 0)
5. 00
。
Note:
Unit:mm(inch)
Pin sectio n:0.60*0.25mm(0.024 *0.010inch)
Pin sectio n tolera nces: 0.10mm( 0.004inch)
General tolera nces: 0.1 5mm( 0.006 in ch)
1
2
5
6
GND
Vin
0V1
Vo1
Vo2
9
10
0V2
Others
NC
NC:No connection
Overload Protection
Under normal operating conditions, the output circuit
of these products has no protection against overload.
The simplest method is to connect a self-recovery fuse
in series at the input end or add a circuit breaker to the
circuit.
No parallel connection or plug and play.