3.0 WATT MINIATURE SIP DC/DC CONVERTER Product Data Sheet HPR2XX FEATURES Four Channels Of Isolated Power High Output Power Density: > 9. 4 Watts/Inch3 Extended Temperature Range: -25°C To +85°C High Efficiency: To 84% Low Cost High Isolation Voltage: 750V Continuous Input-to-Output and Channel-to-Channel Single In-line Package (SIP) Internal Input and Output Filtering Non-Conductive Case The HPR2XX Series is designed for multiple channel applications that require small size and could benefit from a complete onepackage solution. The HPR2XX Series offers four isolated channels of output power in a footprint less than the size of many singular devices. This unregulated series of DC/DC converters provides three watts of total output power. Each isolated channel can supply up to 750mW. or "aliasing" in multiple channel applications. The HPR2XX Series uses advanced circuit design and packaging technology to realize superior reliability and performance. With only one switching converter on the board, the HPR2XX eliminates the possibility of separate converters creating beat frequencies, The HPR2XX Series offers the user low cost without sacrificing reliability. The use of surface mounted devices and manufacturing technologies make it possible to offer premium performance and low cost. The high efficiency of the HPR2XX Series means less internal power dissipation than comparable solutions. With reduced heat to dissipate, the HPR2XX Series can operate at higher temperatures with no degradation in reliablility. In addition, the high efficiency of the HPR2XX Series provides greater than 9 watts/inch3 output power density. MECHANICAL PIN CONNECTIONS 2.210+.010 (56.13) TOP VIEW 0.340+.010 (8.64) 1. -VOUT1 5.-VOUT2 9. +VIN 14. -VOUT3 18. -VOUT4 2. COM 1 6. COM2 10.-VIN 15. COM3 19. COM 4 16. +VOUT3 20. +VOUT4 3 +VOUT1 7.+VOUT2 0.340+.010 (8.64) FRONT VIEW RIGHT SIDE VIEW 0.400+.010 (10.16) 0.030+.010 (0.76) 0.140+.020 (0.25) 0.010+.002 (0.25) 0.020+.002 (0.51) 0.155+.015 (3.94) 0.050+.015 (1.27) All dimensions are in inches (millimeters). GRID: 0.100 inches (2.54 millimeters) PIN PLACEMENT TOLERANCE: ± 0.015" Marked with: specific model ordered, date code, and job code. BOTTOM VIEW 1 2 3 HPR2XX REV E MPS 12/08 5 6 7 9 10 14 15 16 18 19 20 Page 1 ELECTRICAL SPECIFICATIONS NOMINAL RATED INPUT VOLTAGE RATED OUTPUT VOLTAGE INPUT CURRENT OUTPUT CURRENT NO LOAD REFLECTED RIPPLE RATED LOAD CURRENT FICIENCY MODEL (VDC) (VDC) (mA) (mA) (mA) (mAp-p) (%) HPR203 HPR204 HPR205 5 5 5 ±5.2 ±12 ±15 ±73 ±30 ±25 70 75 75 820 750 750 35 35 35 74 80 80 HPR210 HPR211 12 12 ±12 ±15 ±30 ±25 30 30 305 300 15 15 82 84 HPR216 HPR217 15 15 ±12 ±15 ±30 ±25 20 20 240 240 15 20 83 84 HPR221 HPR223 24 24 ±5.0 ±15 ±75 ±25 20 20 170 155 20 20 74 81 MIN TYP MAX UNITS 4.5 10.8 13.5 21.6 5 12 15 24 5.5 13.2 16.5 26.4 1 VDC VDC VDC VDC V/μsec Amps Note: Other input to output voltage options may be available. Please consult factory. COMMON SPECIFICATIONS Specifications typical at TA = +25°C, nominal input voltage, rated output current unless otherwise specified. PARAMETER CONDITIONS INPUT Voltage Range Voltage Rise Time In Rush Current ISOLATION Rated Voltage Test Voltage Resistance Capacitance Leakage Current OUTPUT Total Rated Power Rated Power Each Channel Voltage Setpoint Accuracy Ripple & Noise Voltage At Startup Input to Output, Channel to Channel 60 Hz, 10 seconds 750 750 10 30 4 VISO= 240VAC, 60Hz 3 750 GENERAL Switching Frequency Package Weight Frequency Change MTTF per MIL-HDBK-217, Rev. E Ground Benign Fixed Ground Naval Sheltered Airborne Uninhabited Fighter Internal Power Dissipation............................................................................1.2W Short Circuit Protection.......................................................................< 1 second Page 2 %/%VIN % % 300 7 5 20 kHz g % % 1.8 450 270 45 MHr kHr kHr kHr 8 17 20 Rated Load to 1mA Load High Line to Low Line Circuit Stress Method TA = +25°C TA = +35°C TA = +35°C TA = +35°C ABSOLUTE MAXIMUM RATINGS 1 10 3 40 7 High Line to Low Line Rated Load to 1mA Load Rated Load to 1mA Load TEMPERATURE Specification Operation Storage .05 W mW % mVp-p mVrms VDC VDC VDC %/Deg C ±5 Rated Load, Nominal VIN BW = DC to 10MHz BW =10Hz to 2MHz IL=1mA, VOUT = 5V IL=1mA, VOUT = 12V IL=1mA, VOUT = 15V Temperature Coefficent REGULATION Line Regulation Load Regulation (5V out only) Load Regulation (All other Models) VDC Vpk G7 pF μArms -25 -40 -40 +25 ORDERING INFORMATION Device Family HPR Indicates DC/DC Converter Model Number Selected From Table Above Screening Option +85 +100 +110 °C °C °C HPR 2XX /H HPR2XX REV E MPS 12/08 EF- 420 375 390 High Line 360 Nominal Line 325 330 4.75 5.0 5.25 5.5 0 Channel 2-4 6.2 13.4 VOUT (VDC) 14.0 5.0 Channel 1 .75 1.5 2.25 0 3.0 6 12 18 Pout (Watts) Input Channel 1 (mA) LOAD REGULATION LOAD REGULATION 26 VOUT (VDC) LOAD REGULATION 6.6 5.4 29.5 29.0 Vin (VDC) 5.8 30.0 Low Line 300 4.5 12.8 12.2 11.6 0 20 40 60 80 0 8 16 24 32 -0 Iout (mA sum of all Outputs) Iout (mA sum of all Outputs) REFLECTED RIPPLE CURRENT vs. Pout 50.0 EFFICIENCY vs OUTPUT POWER 90.0 +15Vout +12Vout Efficiency (Pout/Pin) 37.5 25.0 12.5 0 67.5 +5Vout 45.0 22.5 0 0 0.8 1.7 2.6 3.4 0 .85 Pout (Watts) 1.7 2.6 3.5 Pout (Watts) 6.25 12.50 18.75 25 Iout (mA sum of all Outputs) LINE REGULATION 12 Change from Nom Vout (%) VOUT (VDC) 30.5 +VOUT (VDC) 350 300 Reflected Ripple Current (mA p-p) CROSS REGULATION HPR205 31.0 400 Frequency (kHZ) Frequency (kHZ) TYPICAL PERFORMANCE CURVES 6 0 -6 -12 -10 -5 0 5 10 Pout (Watts) The information provided herein is believed to be reliable; however, MuraTA POWER SOLUTIONS assumes no responsibility for inaccuracies or omissions. MuraTA POWER SOLUTIONS assumes no responsibility for the use of this information, and all use of such information shall be entirely at the user’s own risk. Prices and specifications are subject to change without notice. No patent rights or licenses to any of the circuits described herein are implied or granted to any third party. MuraTA POWER SOLUTIONS does not authorize or warrant any MuraTA POWER SOLUTIONS product for use in life support devices/systems or in aircraft control applications. Murata Power Solutions, Inc. 11 Cabot Boulevard, Mansfield, MA 02048-1151 U.S.A. Tel: (508) 339-3000 (800) 233-2765 Fax: (508) 339-6356 USA: Mansfield (MA), Tel: (508) 339 3000, email: [email protected] Canada: Toronto, Tel: (866) 740 1232, email: [email protected] UK: Milton Keynes, Tel: +44 (0)1908 615232, email: [email protected] France: Montigny Le Bretonneux, Tel: +33 (0)1 34 60 01 01, email: [email protected] Germany: München, Tel: +49 (0)89-544334-0, email: [email protected] Japan: Tokyo, Tel: 3-3779-1031, email: [email protected] Osaka, Tel: 6-6354-2025, email: [email protected] China: Shanghai, Tel: +86 215 027 3678, email: [email protected] Guangzhou, Tel: +86 208 221 8066, email: [email protected] www.murata-ps.com email: [email protected] ISO 9001 & ISO 14001 REGISTERED Murata Power Solutions, Inc. makes no representation that the use of its products in the circuits described herein, or the use of other technical information contained herein, will not infringe upon existing or future patent rights. The descriptions contained herein do not imply the granting of licenses to make, use, or sell equipment constructed in accordance therewith. Specifications are subject to change without notice. © 2008 Murata Power Solutions, Inc. HPR2XX REV E MPS 12/08 Singapore: Parkway Centre, Tel: +65 6348 9096, email: [email protected] Page 3