MURATA-PS OKL2-T/3-W12N-C

This data sheet contains core information only. Please click here for the full data sheet.
OKL-T/3-W12 Series
www.murata-ps.com
Programmable Output 3-Amp iLGA SMT PoLs
PRODUCT OVERVIEW
The OKL-T/3 series are miniature non-isolated
Point-of-Load (PoL) DC/DC power converters for
embedded applications. Featuring iLGA inspectable
Land Grid Array (LGA) format, the OKL measures
only 0.48 x 0.48 x 0.25 inches (12.2 x 12.2 x 6.35
mm).
The wide input range is 4.5 to 14 Volts DC. The
maximum output current is 3 Amps (T/3 models).
Based on fixed-frequency synchronous buck converter switching topology, the high power conver-
Typical unit
sion efficient Point of Load (PoL) module features
programmable output voltage and On/Off control.
These converters also include under voltage lock
out (UVLO), output short circuit protection, overcurrent and over temperature protections.
An optional sequence/tracking feature on OKL2
models allows power sequencing of PoL’s. These
units are designed to meet all standard UL/EN/IEC
60950-1 safety certifications and RoHS-6 hazardous substance compliance.
FEATURES
■
iLGA inspectable Land Grid Array
■
4.5-14Vdc input voltage range
■
Programmable output voltage from 0.591-5.5Vdc
■
Drives up to 200 μF ceramic capacitive loads
■
High power conversion efficiency at 93%
■
Outstanding thermal derating performance
■
Over temperature and over current protection
■
On/Off control and Power Good signal
■
Optional Sequence/Tracking operation (OKL2
models)
■
Designed to meet UL/EN/IEC 60950-1 safety
(pending)
■
RoHS-6 hazardous substance compliance
Contents of full data sheet
Description, Connection Diagram, Photograph
Ordering Guide, Model Numbering, Product Label
Mechanical Specifications, Input/Output Pinout
Detailed Electrical Specifications
Output Voltage Adjustment, Application Notes
Soldering Guidelines
Performance Data and Oscillograms
Tape and Reel Information
Page
1
2
3
4
5
7
8
15
Connection Diagram
+Vin
F1
On/Off
Control
+Vout
t4XJUDIJOH
Controller
Sense
t'JMUFST
t$VSSFOU4FOTF
External
DC
Power
Source
Trim
Open = On
Closed = Off
(Positive
On/Off)
Reference and
Error Amplifier
Common
Sequence/Tracking
(OKL2 Models)
Common
Power Good out
Figure 1. OKL-T/3
Note: Murata Power Solutions strongly recommends an external input fuse, F1.
See specifications.
For full details go to
www.murata-ps.com/rohs
www.murata-ps.com
Technical enquiries email: [email protected], tel: +1 508 339 3000
MDC_MDC_OKL-T/3-W12 Series.A05 Page 1 of 4
This data sheet contains core information only. Please click here for the full data sheet.
OKL-T/3-W12 Series
Programmable Output 3-Amp iLGA SMT PoLs
Performance Specifications and Ordering Guide
ORDERING GUIDE
Model Number
Output
Input
Package - Pinout P83
Efficiency On/Off Seq/
Regulation
(max.)
Vout
Iout (Amps, Power R/N (mV p-p)
Vin nom. Range Iin, no load Iin, full load
Case C83
Polarity Track
(Volts) ➀
max.)
(Watts)
Max. ➃
(Volts) (Volts) (mA) ➃ (Amps) ➁ Min. Typ.
inches (mm)
Line
Load
OKL-T/3-W12P-C
0.591-5.5
3
15.0
37
±0.25% ±0.25%
12
4.5-14
20
1.34
91% 93%
Pos.
no
0.48x0.48x0.25
12.2x12.2x6.35
OKL-T/3-W12N-C 0.591-5.5
3
15.0
37
±0.25% ±0.25%
12
4.5-14
20
1.34
91% 93%
Neg.
no
0.48x0.48x0.25
12.2x12.2x6.35
OKL2-T/3-W12P-C 0.591-5.5
3
15.0
Pos.
yes
0.48x0.48x0.25
12.2x12.2x6.35
OKL2-T/3-W12N-C 0.591-5.5
3
15.0
Neg.
yes
0.48x0.48x0.25
12.2x12.2x6.35
Please contact Murata Power Solutions for further information.
➀
➁
The output range is limited by Vin. See detailed specs.
All specifications are at nominal line voltage, Vout=nominal (5V for W12 models) and full load,
+25 deg.C. unless otherwise noted.
➂ Use adequate ground plane and copper thickness adjacent to the converter.
fRipple and Noise (R/N) and no-load input current are shown at Vout=1V. See specs for details.
Output capacitors are 10 μF ceramic. Input cap is 22 μF. See detailed specifications.
I/O caps are necessary for our test equipment and may not be needed for your application.
PART NUMBER STRUCTURE
OK L 2 - T / 3 - W12 N - C
Okami Non-isolated PoL
LGA Surface Mount
Sequence/tracking
Blank = Not installed
2 = Installed
Trimmable Output
Voltage Range
0.591-5.5Vdc
RoHS Hazardous
Substance Compliance
C = RoHS-6 (does not claim EU RoHS exemption
7b–lead in solder)
On/Off Polarity
P = Positive Polarity
N = Negative Polarity
Input Voltage Range
4.5-14Vdc
Maximum Rated Output
Current in Amps
Product Label
Because of the small size of these products, the product label contains a
character-reduced code to indicate the model number and manufacturing date
code. Not all items on the label are always used. Please note that the label
differs from the product photograph. Here is the layout of the label:
Mfg.
date
code
XXXXXX
Product code
YMDX Rev.
Revision level
Model Number
Product Code
OKL-T/3-W12N-C
L00103
OKL-T/3-W12P-C
L01103
OKL2-T/3-W12N-C
L20103
OKL2-T/3-W12P-C
L21103
The manufacturing date code is four characters:
Figure 2. Label Artwork Layout
The label contains three rows of information:
First row – Murata Power Solutions logo
Second row – Model number product code (see table)
Third row – Manufacturing date code and revision level
www.murata-ps.com
First character – Last digit of manufacturing year, example 2009
Second character – Month code (1 through 9 and O through D)
Third character – Day code (1 through 9 = 1 to 9, 10=O and
11 through 31 = A through Z)
Fourth character – Manufacturing information
Technical enquiries email: [email protected], tel: +1 508 339 3000
MDC_MDC_OKL-T/3-W12 Series.A05 Page 2 of 4
This data sheet contains core information only. Please click here for the full data sheet.
OKL-T/3-W12 Series
Programmable Output 3-Amp iLGA SMT PoLs
MECHANICAL SPECIFICATIONS
Top View
INPUT/OUTPUT CONNECTIONS
0.043 (1.09)
NOM. PCB
THK
0.48
(12.19)
Bottom View
0.48
(12.19)
Side View
NOTE:
In case of solder-wicking, this
terminal is connected to Vout.
Pin
1
2
3
4
5
6
7
8
9
10
11
12
Function
On/Off Control*
VIN
Ground
VOUT
Sense
Trim
Ground
NC
Sequence/Tracking†
Power Good out
NC
NC
*The Remote On/Off can be provided with
either positive (P suffix) or negative (N
suffix) polarity
†
OKL2 Models
0.25
(6.35)
End View
Recommended Footprint
-through the Board-
2
2
Vin
Gnd
Vout
0.375 (9.53)
5
11
0.150 (3.81)
6
Trim
Vin
Sense
On/Off
NC
PGood
NC
Gnd
NC
1
10
CL
CL
0.090
(2.29)
9
NC
PG
NC Gnd
8
7
NC
11
0.180 (4.57)
Trim
12
0.090
(2.29)
0.180 0.090
(4.57) (2.29)
0.420 (10.67)
0.180 (4.57)
0.135 (3.43)
5
6
9
8
0.330 (8.38)
0.240 (6.10)
0.150 (3.81)
7
Sense
10
Seq
12
4
Gnd
1 On/Off
Seq
0.060 (1.52)
0
0.480 REF (12.19)
0.420 (10.67)
0.240 (6.10)
3
0.070 x 0.160 x3
(1.77 x 4.07)
Vout
3
4
0.480 (12.19)
0.135
0.180
(3.43)
(4.57)
0.045
(1.14)
0.375 (9.53)
0.195 (4.95)
0
0.060 (1.52)
Bottom View
Dimensions are in inches (mm shown for ref. only).
Third Angle Projection
0.040 x 0.040 x9
(1.01 x 1.01)
Tolerances (unless otherwise specified):
.XX ± 0.02 (0.5)
.XXX ± 0.010 (0.25)
Angles ± 1˚
Figure 3. OKL-T/3 Mechanical Outline
www.murata-ps.com
Components are shown for reference only.
Technical enquiries email: [email protected], tel: +1 508 339 3000
MDC_MDC_OKL-T/3-W12 Series.A05 Page 3 of 4
This data sheet contains core information only. Please click here for the full data sheet.
OKL-T/3-W12 Series
Programmable Output 3-Amp iLGA SMT PoLs
USA:
Murata Power Solutions, Inc.
11 Cabot Boulevard, Mansfield, MA 02048-1151 U.S.A.
Tel: (508) 339-3000 (800) 233-2765 Fax: (508) 339-6356
www.murata-ps.com email: [email protected] ISO 9001 and 14001 REGISTERED
Toronto, Tel: (866) 740-1232, email: [email protected]
UK:
Milton Keynes, Tel: +44 (0)1908 615232, email: [email protected]
France:
Montigny Le Bretonneux, Tel: +33 (0)1 34 60 01 01, email: [email protected]
Germany:
München, Tel: +49 (0)89-544334-0, email: [email protected]
Japan:
Tokyo, Tel: 81-3-3779-1031, email: [email protected]
Kyoto, Tel: 81-75-955-7269, email: [email protected]
China:
Shanghai, Tel: +86 215 027 3678, email: [email protected]
Guangzhou, Tel: +86 208 221 8066, email: [email protected]
Singapore:
Parkway Centre, Tel: +65 6348 9096, email: [email protected]
07/31/09
Murata Power Solutions, Inc. makes no representation that the use of its products in the circuits described herein, or the use of other
technical information contained herein, will not infringe upon existing or future patent rights. The descriptions contained herein do not imply
the granting of licenses to make, use, or sell equipment constructed in accordance therewith. Specifications are subject to change without
notice.
© 2009 Murata Power Solutions, Inc.
www.murata-ps.com
Mansfield (MA), Tel: (508) 339-3000, email: [email protected]