NIEC PHA15DW2RP

PHA15DW2RP PHA15DW2RPS
SSR
240V 15 / 25A (RMS)
PHA25DW2RP PHA25DW2RPS
Function
* Single Pole, Single Throw Normally Open
* With Zero Crossing Voltage Switching Circuit
* Equipped Heat Sink Standard
Futures
* Easy Installation with DIN Rail Mounting
* Low Noise Switching and Rush Current
* Space Save Mounting
* High Voltage Isolation
Characteristics and Ratings
Parameter
Symbol
Characteristics / Ratings
PHA15DW2RP PHA15DW2RPS PHA25DW2RP PHA25DW2RPS
Unit
Output
Rated Voltage
V(RMS)
240
V
A.C. Line Voltage Range
V(RMS)
60 to 280
V
f
47 to 63
HZ
Operating Frequency
Maximum Load Current
Non-repetitive One Cycle Surge Current
IT(RMS)
15
25
A
ITSM
150
250
A
Minimum Operating Current
Iop(RMS)
100
mA
Maximum off-state Leakage Current
Maximum on-sate Voltage Drop
Ileak(RMS)
9.0
mA
VT(RMS)
1.6
V
T(rps)
1/2 Cycle + 1mS
-
Control Signal Voltage Range
IIN(DC)
4.5 to 30
V
Input Current
IF(DC)
10
mA
Pick-up Voltage
PUV
4.5
V
Drop-out Voltage
DOV
1.0
V
Response Time
Input
Input/Output
AC Isolation Voltage (Between Input ,
Output Terminals and Base)
Capacitance (Between input and output
Viso(RMS)
C(i-o)
2500
4000 *1
2500
4000 *1
V
pF
100
Operating Temperature Range
Top
-30 to
+80
°C
Storage Temperature Range
Tstg
-35 to +100
°C
*1: When the maximum insulation characteristic is necessary , we recommended the use of the insulation sheet.
(Typical)
PHA15DW2RP
/
(Typical)
PHA15DW2RPS
(Maximum)
(Maximum)
PHA25DW2RP / PHA25DW2RPS
(Maximum)
(Maximum)
PHA15DW2RP OUT LINE DRAWING
PHA25DW2RP OUTLINE DRAWING
PHA15DW2RPS OUT LINE DRAWING
PHA25DW2RP S OUTLINE DRAWING