AZETTLER SGX-41F1D380A4PSG

SGX-41F
SOLID STATE RELAY
4 AMPS
48 TO 400 VRMS
FEATURES
•
•
•
•
•
•
•
•
Photo isolation
Up to 800V blocking voltage
Both zero cross or random turn-on
High surge capability
Built-in snubber
UL, CUR file E43203
SCR or Triac Output Circuitry
RoHS compliant
INPUT
Type
Control Voltage Range
Turn On Voltage
Turn Off Voltage
Max. Input Current
Max. Reverse Voltage
1D
2D
3 to 15 VDC
15 to 32 VDC
3 VDC max.
15 VDC max.
1 VDC min.
1 VDC min.
40 mA at 15 VDC
20 mA at 32 VDC
-15 VDC
-32 VDC
OUTPUT
Type
Output Voltage Range
Blocking Voltage
Max. Leakage Current (off)
240
380
48 to 264 VAC
48 to 400 VAC
600 Vpk
800 Vpk
5 mA
5 mA
Max. Voltage Drop (at rated current)
1.7 VRMS
Min. Load Current
100 mA
Max. Turn-On Time
Random Turn On (DC input): 1 ms
Zero Cross Turn On (DC input): 1/2 cycles + 1 ms
AC Input: 20 ms
Max. Turn-Off Time
DC Input: 1/2 cycle + 1 ms
AC Input: 40 ms
Min. Off-State (dv/dt)
Triac: 200 V/us / SCR: 500 V/us
GENERAL
Dielectric Strength
4000 Vrms min. (at 50/60 Hz, 1 min.)
Insulation Resistance
1000 Min. (at 500 VDC)
Ambient Temperature
Operating: -30°C (-22°F) to 80°C (176°F)
Storage: -30°C (122°F) to 100°C (212°F)
Termination
PCB
Weight
15g
3/29/06W
SGX-41F
RELAY ORDERING DATA
SGX-41F
1D
MODEL
240
INPUT
VOLTAGE
1D: 3 TO 15 Vdc
2D: 15 to 32 Vdc
A
4
OPERATING
VOLTAGE RANGE
LOAD
TYPE
240:48 TO 264 Vac
380: 48 to 400 Vac
A: AC LOAD
Z
LOAD
CURRENT
4: 4A
S
ZERO CROSS OUTPUT DEVICE
OR RANDOM
Z: Zero cross
turn on
P: Random
turn on
S: SCR
Nil: Triac
G
PACKAGE
G: epoxy
MECHANICAL DATA
Outline Dimensions
PC Board Layout
1.724MAX
[43.8]
.374MAX
[9.5]
Ø0.047
[1.2]
.200
[5.08]
1.043MAX
[26.5MAX]
.118MAX
[3.0]
.100
[2.54]
0.200
[5.1]
.370
[9.4]
Ø.039
[1.0]
.201
[5.1]
1.100
[27.9]
.098MAX
[2.5]
.701
[17.8]
1.098
[27.9]
0.700
[17.8]
Wiring Diagram
-4
+3
2
1
Load
Input control
Power supply
Dimensions in inches with metric equivalents in parentheses. Tolerance: ± .010"
INSTALLATION
PRECAUTIONS
1.
1.
Before connecting a load that generates a high surge current,
such as a lamp load to the SSR, make sure that the SSR can
withstand the surge current of the load.
2.
The product data sheet shows the non-repetitive peak value of
the surge current that flows through the SSR. Normally, use 1/2
of the non-repetitive peak surge current as the standard value. If
a surge current exceeding that value is expected, connect a
quick-blowing fuse to protect the SSR.
When mounting the relays side by side, provide a space equivalent
to the width of a single SSR between two adjacent SSRs.
Otherwise, reduce the load current flow to 1/2 to 1/3 of the rated current.
3/29/06W
SGX-41F
CHARACTERISTIC CURVES
Figure 1 Maximum load current
vs. ambient temperature
3/29/06W