NI UES-3880

Industrial Ethernet Switches – Managed and Unmanaged
NI UES-3880, NI MES-3980 NEW!
Industrial Features
• -40 to 70 °C operating temperature
• Redundant dual 24 VDC power inputs
• Class I, Div 2; ATEX Class 1,
Zone 2 hazardous certifications
• Metal enclosure, IP30 rated
• DIN-rail or panel mount support
• Relay output warning for power failure
and port break alarm
Switching Features
•
•
•
•
Eight 10/100BASE-T(X) RJ45 connectors
Broadcast storm protection
IEEE 802.3/802.3u/802.3x support
10/100 M full-/half-duplex,
MDI/MDI-X autosensing
Overview and Applications
Managed Ethernet Switch
The National Instruments unmanaged Ethernet switch (UES) and
managed Ethernet switch (MES) provide the switching you need to
connect all NI Ethernet-based devices to distributed systems and
incorporate Ethernet-based devices and industrial protocols from
third-party suppliers into NI applications.
The eight-port NI MES-3980 is a fully managed switch for networking NI
Ethernet-based devices. The MES offers the same industrial
specifications as the unmanaged switch as well as additional network
management, network monitoring and security, network redundancy, and
system alarm functionality. The MES-3980 provides Web-based
configuration for easy management of these features and a Windows
utility for configuration. MES-3980 features include:
• Web-based and Windows configuration and management
• Ring recovery time <300 ms at full load with Turbo Ring technology
• RSTP/STP (IEEE 802.1D-2004) for Ethernet redundancy
• Quality of Service (QoS) IEEE 802.1p/1Q for network determinism
• IGMP snooping and GMRP for filtering multicast traffic
• Port trunking and LACP for optimum bandwidth limitation
• Port-based VLAN and GVRP for network planning
• RMON and SNMP v1/v2c/v3 for network monitoring
and management
• IEEE 802.1X port-based network access control, https/SSL secure Web
access, and port lock by MAC address for network security
• Configurable e-mail notifications
• Relay output for power failure, and port break alarms and digital
inputs to integrate control systems and sensors
• Automatic backup configurator support
Unmanaged Ethernet Switch
The eight-port NI UES-3880 is an unmanaged entry-level switch for
networking between NI Ethernet-based controllers and devices using
standard Ethernet protocols. The UES offers industrial features for
networking NI programmable automation controllers (PACs) including
-40 to 70 °C operating temperatures; Class I, Div 2, and ATEX
certifications for hazardous locations; and redundant dual 24 VDC
power inputs.
46.00 mm
(1.82 in.)
NATIONAL
INSTRUMENTS
PWR1
PWR2
FAULT
NI-UES-3880
44.00 mm
(1.73 in.)
Unmanaged Ethernet Switch
135.00 mm
(5.31 in.)
DIN-Rail
Kit
105.00 mm
(4.13 in.)
Side View
Rear View
53.60 mm
(2.11 in.)
Front View
Figure 1. NI UES-3880 Dimensional Drawings
18.20 mm
(0.72 in.)
Panel
Mounting Kit
Industrial Ethernet Switches – Managed and Unmanaged
Network Management
The MES-3980 provides port trunking, so you can group two or more
ports together for increased bandwidth and a backup communication
path. The managed switch implements the Link Aggregation Control
Protocol (LACP) based on IEEE 802.3ad to provide link aggregation.
It also offers port-based virtual LAN (VLAN) support for creating
independent logical networks across switches or on the same switching
hardware. The MES-3980 implements the Generic Attribute Registration
Protocol (GARP), and, to support VLANs, it uses the GARP VLAN
Registration Protocol (GVRP) based on IEEE 802.1Q. The NI managed
switch, configured for the VLAN in which it is incorporated, uses the
GVRP to spread necessary information and configure other switches
across VLANs.
MES-3980 supports RSTP and can be incorporated as part of a corporate
IT networking infrastructure.
When you need to implement a private subnet, Turbo Ring offers a
simple method of redundancy that the NI managed switch supports.
Figure 2 shows a ring system with the backup path. If any section
between two switches is broken, the ring can recover communication
within 300 ms with the backup path.
Network Monitoring and Security
Port mirroring allows one port on a switch to check the traffic sent and
received by another port for network monitoring. With remote monitoring
(RMON) support, network administrators can obtain network-fault
diagnosis, planning, and performance-tuning data from the NI managed
switch. Using these features, the MES-3980 provides a wide range of
industry-standard options for network monitoring.
The MES-3980 uses the Simple Network Management Protocol
(SNMP) so network management systems can access data from the
switch to describe system configuration. Network management systems
use SNMP to monitor devices attached to the network.
The most common concern with Ethernet is security. The NI managed
switch offers MAC filtering control so you can configure a table of
acceptable MAC addresses that the switch uses to filter traffic from
unauthorized devices.
The NI managed switch also supports Port Lock access by MAC
address so that locked ports such as those connected to the external
network are not able to learn other MAC addresses and only pass traffic
sent from preset MAC addresses. This helps to avoid inappropriate port
usage by external devices.
Network Redundancy and Industrial
Protocol Support
The MES-3980 supports the Spanning Tree Protocol (STP) and
Rapid STP (RSTP) developed by Cisco and now incorporated in the
IEEE 802.1D-2004 standard. In addition to STP and RSTP, the managed
switch works with Turbo Ring technology, which provides ring recovery
time <20 ms for Ethernet redundancy when an Ethernet network is
configured using a ring topology. IT administrators typically use STP
and RSTP to implement redundancy in corporate IT networks. The
Figure 2. Ring Configuration for Communication Redundancy
NI unmanaged and managed Ethernet switches work with PC-based
Ethernet standards based on the IEEE 802.3 application and transport
layers of the TCP/IP protocols. Both the UES-3880 and MES-3980 are
compatible with NI shared variables and industrial protocols that rely
on TCP/IP protocols, including Modbus TCP/IP, UDP, and TCP.
Additional industrial protocols, including Ethernet/IP and PROFINET,
add more requirements to the transport layers of TCP/IP and are
supported only by the MES-3980. The NI managed switch offers Internet
Group Management Protocol (IGMP) snooping and supports the GARP
Multicast Registration Protocol (GMRP) that allows the managed switch
to filter multicast traffic such as traffic generated from Ethernet/IP
networks. For applications involving NI Ethernet-based hardware on a
network with PROFINET I/O, the MES-3980 provides packet prioritization
based on the Quality of Service (QoS) IEEE 802.1p/1Q standard that
defines priority levels for individual packets routed on a network.
System Notification and
Backup Configuration
The NI managed switch offers several features for power failure and port
break detection. For system management, the MES-3980 delivers
configurable e-mail notifications when an exception is detected,
providing system managers with real-time alarm messages. For local
alarms and notifications, the MES-3980 offers two relay contacts with a
BUY ONLINE at ni.com or CALL 800 813 3693 (U.S.)
2
Industrial Ethernet Switches – Managed and Unmanaged
current capacity of 1 A at 24 V. These relay outputs can connect directly
to local sensors or to digital inputs on NI PACs such as CompactRIO and
Compact FieldPoint, so NI LabVIEW software can detect port failure or
switch power failure. The switch also provides two digital inputs with 8
A maximum input current and two output states. NI PACs can set these
digital inputs to alert the switch about events or alarm notifications.
The MES-3980 also supports backup configuration through an
automatic RJ45 cable and storage device. The backup configurator
stores IP address and switch management settings. Upon switch
replacement, simply reboot the switch and the backup configurator
updates IP address and system settings.
Web-Based Configuration
The MES-3980 is shipped with Web-based management software for
configuration. Simply log in using the switch IP address and navigate to
change settings and customize the switch. You can easily export or
import settings to replicate to other switches or to import existing files
of settings from an already configured switch.
Mechanical Dimensions
MES-3980 switch dimensions are shown in Figure 4. Each switch is
shipped with a DIN-rail mount bracket and power connectors for
redundant power inputs, relay outputs, and two digital lines.
46.00 mm
(1.82 in.)
NATIONAL
INSTRUMENTS
PWR1
PWR2
FAULT
70.00 mm
(2.77 in.)
MASTER
COUPLER
135.00 mm
(5.31 in.)
DIN-Rail
Kit
NI-MES-3980
Managed Ethernet Switch
105.00 mm
(4.13 in.)
Side View
Rear View
80.20 mm
(3.16 in.)
Front View
18.20 mm
(0.72 in.)
Panel
Mounting Kit
Figure 4. NI MES-3980 Dimensional Drawings
Figure 3. NI Managed Ethernet Switch Web-Based Configuration Software
Ordering Information
NI UES-3880 ..........................................................................780038-01
NI MES-3980 ........................................................................780039-01
Accessory
NI PS-5 Power Supply ..........................................................778805-90
BUY NOW!
For complete product specifications, pricing, and accessory
information, call 800 813 3693 (U.S.) or go to ni.com/comm.
BUY ONLINE at ni.com or CALL 800 813 3693 (U.S.)
3
Industrial Ethernet Switches – Managed and Unmanaged
Power
Specifications
>> For complete specifications, see the NI MES-3980 User Manual
at ni.com/manuals.
Technology
UES-3880
Standards........................................
Processing type...............................
Flow control ....................................
MES-3980
Standards........................................
IEEE 802.3, 802.3u, 802.3x
Store and forward
IEEE 802.3x back pressure
IEEE 802.3, 802.3u, 802.3x,
802.1D, 802.1w, 802.1Q, 802.1p,
802.1X, 802.3ad
Protocols ......................................... IGMP v1/v2/v3 device, GVRP,
SNMP v1/v2c/v3, DHCP
Server/Client, DHCP Option 82,
BOOTP, TFTP, SNTP, SMTP, RARP,
GMRP, LACP, RMON
MIB ................................................. MIB-II; Ethernet-Like;
P-BRIDGE; Q-BRIDGE; Bridge;
RSTP; RMON groups 1, 2, 3, and 9
Flow control .................................... IEEE 802.3x back pressure
Interface
UES-3880
RJ45 ports....................................... 10/100BASE-T(X) autonegotiation
speed, F/H duplex mode, and
auto MDI/MDI-X connection
LED indicators................................. PWR1, PWR2, Fault, 10/100M
(TP port), and 100M (fiber port)
DIP switch....................................... Port break alarm mask
Alarm contact ................................. One relay output with current
carrying capacity of 1 A @ 24 VDC
MES-3980
RJ45 ports....................................... 10/100BASE-T(X) autonegotiation
speed, F/H duplex mode, and
auto MDI/MDI-X connection
LED indicators................................. PWR1, PWR2, Fault, Master,
Coupler, 10/100M
DIP switch....................................... Turbo Ring, Master,
Coupler, Reserve
Alarm contact ................................. Two relay outputs with current
carrying capacity of 1 A @ 24 VDC
Digital input ........................................ Two inputs with the same
ground but electrically isolated
from the electronics
+13 to +30 V for state “1”
-30 to +3 V for state “0”
Maximum input current ...................... 8 mA
UES-3880
Input voltage................................... 24 VDC (12 to 48 VDC),
redundant inputs
Input current ................................... 0.25 A @ 24 VDC
Connection...................................... Removable 6-pin terminal block
Overload current protection ........... 1.1 A
Reverse polarity protection ............ Present
MES-3980
Input voltage................................... 24 VDC (12 to 45 VDC),
redundant dual inputs
Input current ................................... 0.25 A @ 24 VDC
Connection...................................... 2 removable 6-pin
terminal blocks
Overload current protection ........... Present, can withstand 1.6 A
Reverse polarity protection ............ Present
Mechanical
UES-3880
Casing ............................................. IP30 protection, metal case
Dimensions (w by h by d) ............... 53.6 by 135 by 105 mm
(2.11 by 5.31 by 4.13 in.)
Weight ............................................ 630 g
Installation...................................... DIN-rail or panel mounting
(optional kit)
MES-3980
Casing ............................................. IP30 protection, aluminum case
Dimensions (w by h by d) ............... 80.5 by 135 by 105 mm
(3.17 by 5.31 by 4.13 in.)
Weight ............................................ 1040 g
Installation...................................... DIN-rail or panel mounting
(optional kit)
Environmental
UES-3880
Operating temperature ...................
Storage temperature ......................
Ambient relative humidity ..............
MES-3980
Operating temperature ...................
-40 to 70 °C (-40 to 158 °F)
-40 to 85 °C (-40 to 185 °F)
5 to 95% (noncondensing)
-40 to 70 °C (-40 to 158 °F)
for T models
Storage temperature ...................... -40 to 85 °C (-40 to 185 °F)
Ambient relative humidity .............. 5 to 95% (noncondensing)
Regulatory Approvals
UES-3880
Safety.............................................. UL60950-1, CSA C22.2
No. 60950-1, EN60950-1, TUV
Hazardous location ......................... UL/cUL Class I, Division 2,
Groups A, B, C, and D
EMI.................................................. FCC Part 15, CISPR (EN55022)
Class A
BUY ONLINE at ni.com or CALL 800 813 3693 (U.S.)
4
Industrial Ethernet Switches – Managed and Unmanaged
EMS ................................................ EN61000-4-2 (ESD) Level 3,
EN61000-4-3 (RS) Level 3,
EN61000-4-4 (EFT) Level 3,
EN61000-4-5 (Surge) Level 3,
EN61000-4-6 (CS) Level 3
MES-3980
Safety.............................................. UL60950-1, CSA C22.2
No. 60950-1, EN60950-1, TUV
Hazardous location ......................... UL/cUL Class I, Division 2,
Groups A, B, C, and D
Maritime ......................................... DNV, GL
EMI.................................................. FCC Part 15, CISPR (EN55022)
Class A
EMS ................................................ EN61000-4-2 (ESD), Level 3,
EN61000-4-3 (RS), Level 3,
EN61000-4-4 (EFT), Level 3,
EN61000-4-5 (Surge), Level 3,
EN61000-4-6 (CS), Level 3,
EN61000-4-8, EN61000-4-11
BUY ONLINE at ni.com or CALL 800 813 3693 (U.S.)
5
NI Services and Support
NI has the services and support to meet
your needs around the globe and through
the application life cycle – from planning
and development through deployment
and ongoing maintenance. We offer
services and service levels to meet
customer requirements in research,
design, validation, and manufacturing.
Visit ni.com/services.
Training and Certification
NI training is the fastest, most certain route to productivity with our
products. NI training can shorten your learning curve, save development
time, and reduce maintenance costs over the application life cycle. We
schedule instructor-led courses in cities worldwide, or we can hold a
course at your facility. We also offer a professional certification program
that identifies individuals who have high levels of skill and knowledge on
using NI products. Visit ni.com/training.
Professional Services
Our NI Professional Services team is composed of NI applications
and systems engineers and a worldwide National Instruments Alliance
Partner program of more than 600 independent consultants and
integrators. Services range
from start-up assistance to
turnkey system integration.
Visit ni.com/alliance.
OEM Support
We offer design-in consulting and product integration assistance if you
want to use our products for OEM applications. For information about
special pricing and services for OEM customers, visit ni.com/oem.
ni.com • 800 813 3693
National Instruments • [email protected]
Local Sales and Technical Support
In offices worldwide, our staff is local to the country, giving you access
to engineers who speak your language. NI delivers industry-leading
technical support through online knowledge bases, our applications
engineers, and access to 14,000 measurement and automation
professionals within NI Developer Exchange forums. Find immediate
answers to your questions at ni.com/support.
We also offer service programs that provide automatic upgrades to
your application development environment and higher levels of technical
support. Visit ni.com/ssp.
Hardware Services
NI Factory Installation Services
NI Factory Installation Services (FIS) is the fastest and easiest way to
use your PXI or PXI/SCXI combination systems right out of the box.
Trained NI technicians install the software and hardware and configure
the system to your specifications. NI extends the standard warranty by
one year on hardware components (controllers, chassis, modules)
purchased with FIS. To use FIS, simply configure your system online
with ni.com/pxiadvisor.
Calibration Services
NI recognizes the need to maintain properly calibrated devices for
high-accuracy measurements. We provide manual calibration
procedures, services to recalibrate your products, and automated
calibration software specifically designed for use by metrology
laboratories. Visit ni.com/calibration.
Repair and Extended Warranty
NI provides complete repair services for our products. Express repair
and advance replacement services are also available. We offer
extended warranties to help you meet project life-cycle requirements.
Visit ni.com/services.
*351533A-01*
351533A-01
2007-9140-161-101-D
© 2007 National Instruments Corporation. All rights reserved. CompactRIO, FieldPoint, LabVIEW, National Instruments, National Instruments Alliance Partner, NI, ni.com, and SCXI
are trademarks of National Instruments. Other product and company names listed are trademarks or trade names of their respective companies. A National Instruments Alliance Partner
is a business entity independent from NI and has no agency, partnership, or joint-venture relationship with NI.