OENINDIA 63D-12-1AE

63
HEAV Y DUTY POWER RELAY
•
•
•
•
•
•
•
Upto 30 A Switching
High Performance
Spade Terminals for Power Output
High Reliability
AC & DC Versions
Sealed
UL Approved
SPECIFICATIONS
COIL DATA
Rated Voltage
: 230 VAC/24 VDC
Ma ximum Voltage
: 250 VAC
Ma ximum Continuous
Current @ 230 VAC/24VDC
: 30A
Motor Load
: 2HP/230VAC
1 Form C
: 30 / 20 A
Ma ximum Power Rating
Nominal Coil Power
3.75
0.6
27
6
4.50
0.9
40
12
9.00
1.2
160
18
13.50
1.8
380
24
18.00
2.4
660
DC
: 2VA
: 0.5W (approx)
Life Expectancy
: 10 operations
Electrical
: 10 operations
Contact Resistance
VAC
VAC
Ohms
230
190
23
13,490
2 x Ø1.2±0.1
: 50 milli Ohms (Initial)
: 2500 VRMS
: 1500 VAC
Insulation Resistance
Specialities
if any
Sealed
D : DC Coil
A : AC Coil
Contact arrangement
1A - Form A
1C -1 Form C
Coil Voltage
(Refer coil data)
CIRCUIT DIAGRAMS
5
1
3
2
Limiting Curve for Power Load
100
30
20
NO
NC
10
AC
Resistive
DC Resistive
1
1
3.80
Between Contacts & Coil
XXX
14.00
Dielectric Strength
Between Contacts
E
4
VAC
5
12 - 1A
View : Terminal Side
DRILLING PATTERN
7
Mechanical
-
Product
Series
AC Coil Data
DC
AC
D
: 7500VA (SPST)
: 0.93W (approx)
Operating Power
5
63
Contact Current (A)
1 Form A
Coil Resistance
Ohms ± 10%
Contact Rating
Drop-out Voltage
VDC (Min)
: Silver Alloy
Pick-up Voltage
VDC (Ma x)
: 1 Form A/1 Form C
Nominal Voltage
VDC
Contact Arrangement
Contact Material
HOW TO ORDER
: 1000 Meg.Ohms at
500VDC,
20
100
200
Contact Voltage(V)
0
25 C,RH50
DIMENSIONS
: 10 milli sec.(Typ)
27.5
: 8 milli sec.(Typ)
Ambient Temperature
: –55 C to +100 C
Weight
: 35gms (approx)
0
cleaning.
Typical applications
Air Conditioning Systems, Ventilation, Heater,
Domestic Appliances, Automotive.
28.0
*
0
* The tab on the cover should be removed af ter PCB
0.8
6.4
Release time
at Nominal Voltage
32.4
Operate time
at Nominal Voltage
0.5
All dimensions are in mm. Specifications subject to change
without notice. Tolerance unless otherwise specified is ± 10%
* Vent hole to be opened after PCB Soldering & Cleaning
3.3±0.05
1000