NSC DP83257VF

October 1994
DP83256/56-AP/57
PLAYER a TM Device (FDDI Physical Layer Controller)
Y
General Description
The DP83256/56-AP/57 Enhanced Physical Layer Controller (PLAYER a device) implements one complete Physical
Layer (PHY) entity as defined by the Fiber Distributed Data
Interface (FDDI) ANSI X3T9.5 standard.
The PLAYER a device integrates state of the art digital
clock recovery and improved clock generation functions to
enhance performance, eliminate external components and
remove critical layout requirements.
FDDI Station Management (SMT) is aided by Link Error
Monitoring support, Noise Event Timer (TNE) support, Optional Auto Scrubbing support, an integrated configuration
switch and built-in functionality designed to remove all stringent response time requirements such as PCÐReact and
CFÐReact.
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Features
Y
Y
Y
Y
Single chip FDDI Physical Layer (PHY) solution
Integrated Digital Clock Recovery Module provides enhanced tracking and greater lock acquisition range
Integrated Clock Generation Module provides all necessary clock signals for an FDDI system from an external
12.5 MHz reference
Y
Y
Y
Y
Y
Alternate PMD Interface (DP83256-AP/57) supports
UTP twisted pair FDDI PMDs with no external clock recovery or clock generation functions required
No External Filter Components
Connection Management (CMT) Support (LEM, TNE,
PCÐReact, CFÐReact, Auto Scrubbing)
Full on-chip configuration switch
Low Power CMOS-BIPOLAR design using a single 5V
supply
Full duplex operation with through parity
Separate management interface (Control Bus)
Selectable Parity on PHY-MAC Interface and Control
Bus Interface
Two levels of on-chip loopback
4B/5B encoder/decoder
Framing logic
Elasticity Buffer, Repeat Filter, and Smoother
Line state detector/generator
Supports single attach stations, dual attach stations
and concentrators with no external logic
DP83256 for SAS/DAS single path stations
DP83257 for SAS/DAS single/dual path stations
DP83256-AP for SAS/DAS single path stations that require the alternate PMD interface
TL/F/11708 – 1
FIGURE 1-1. FDDI Chip Set Overview
TRI-STATEÉ is a registered trademark of National Semiconductor Corporation.
BMACTM , BSITM , CDDTM , CDLTM , CRDTM , CYCLONETM , MACSITM , PLAYERTM , PLAYER a TM and TWISTERTM are trademarks of National Semiconductor Corporation.
C1995 National Semiconductor Corporation
TL/F/11708
RRD-B30M115/Printed in U. S. A.
DP83256/56-AP/57 PLAYER a Device (FDDI Physical Layer Controller)
PRELIMINARY
Table of Contents
5.21 Current State Prescale Count Register (CSPCR)
1.0 FDDI CHIP SET OVERVIEW
1.1 FDDI 2-Chip Set
5.22 Link Error Threshold Register (LETR)
1.2 FDDI TP-PMD Solutions
5.23 Current Link Error Count Register (CLECR)
5.24 User Definable Register (UDR)
5.25 Device ID Register (DIR)
5.26 Current Injection Count Register (CIJCR)
5.27 Interrupt Condition Comparison Register (ICCR)
5.28 Current Transmit State Comparison Register
(CTSCR)
5.29 Receive Condition Comparison Register A (RCCRA)
5.30 Receive Condition Comparision Register B (RCCRB)
5.31 Mode Register 2 (MODE2)
5.32 CMT Condition Comparison Register (CMTCCR)
5.33 CMT Condition Register (CMTCR)
5.34 CMT Condition Mask Register (CMTCMR)
5.35 Reserved Registers 22H-23H (RR22H-RR23H)
5.36 Scrub Timer Threshold Register (STTR)
5.37 Scrub Timer Value Register (STVR)
2.0 ARCHITECTURE DESCRIPTION
2.1 Block Overview
2.2 Interfaces
3.0 FUNCTIONAL DESCRIPTION
3.1 Clock Recovery Module
3.2 Receiver Block
3.3 Transmitter Block
3.4 Configuration Switch
3.5 Clock Generation Module
3.6 Station Management Support
3.7 PHY-MAC Interface
3.8 PMD Interface
4.0 MODES OF OPERATION
5.38 Trigger Definition Register (TDR)
5.39 Trigger Transition Configuration Register (TTCR)
5.40 Reserved Registers 28H-3AH (RR28H-RR3AH)
5.41 Clock Generation Module Register (CGMREG)
5.42 Alternate PMD Register (APMDREG)
5.43 Gain Register (GAINREG)
5.44 Reserved Registers 3EH-3FH (RR3EH-RR3FH)
4.1 Run Mode
4.2 Stop Mode
4.3 Loopback Mode
4.4 Device Reset
4.5 Cascade Mode
5.0 REGISTERS
5.1 Mode Register (MR)
5.2 Configuration Register (CR)
5.3 Interrupt Condition Register (ICR)
5.4 Interrupt Condition Mask Register (ICMR)
5.5 Current Transmit State Register (CTSR)
5.6 Injection Threshold Register (IJTR)
5.7 Injection Symbol Register A (ISRA)
5.8 Injection Symbol Register B (ISRB)
5.9 Current Receive State Register (CRSR)
5.10 Receive Condition Register A (RCRA)
5.11 Receive Condition Register B (RCRB)
5.12 Receive Condition Mask Register A (RCMRA)
5.13 Receive Condition Mask Register B (RCMRB)
5.14 Noise Threshold Register (NTR)
5.15 Noise Prescale Threshold Register (NPTR)
5.16 Current Noise Count Register (CNCR)
5.17 Current Noise Prescale Count Register (CNPCR)
5.18 State Threshold Register (STR)
5.19 State Prescale Threshold Register (SPTR)
5.20 Current State Count Register (CSCR)
6.0 SIGNAL DESCRIPTIONS
6.1 DP83256VF Signal Descriptions
6.2 DP83256VF-AP Signal Descriptions
6.3 DP83257VF Signal Descriptions
7.0 ELECTRICAL CHARACTERISTICS
7.1 Absolute Maximum Ratings
7.2 Recommended Operating Conditions
7.3 DC Electrical Characteristics
7.4 AC Electrical Characteristics
8.0 CONNECTION DIAGRAMS
8.1 DP83256VF Connection Diagram/Pin Descriptions
8.2 DP83256VF-AP Connection Diagram/Pin Descriptions
8.3 DP83257VF Connection Diagram/Pin Descriptions
9.0 PACKAGE INFORMATION
9.1 Land Patterns
9.2 Mechanical Drawings
2
1.0 FDDI Chip Set Overview
DP83266 MACSI TM Device Media
Access Controller and System
Interface
National Semiconductor’s next generation FDDI 2-chip set
consists of two components as shown in Figure 1-1 . The
PLAYER a device integrates the features of the DP83231
CRDTM Clock Recovery Device, DP83241 CDDTM Clock
Distribution Device, and DP83251/55 PLAYERTM Physical
Layer Controller. In addition, the PLAYER a device contains
enhanced SMT support.
National Semiconductor’s FDDI TP-PMD Solutions consist
of two componentsÐthe DP83222 CYCLONETM Twisted
Pair FDDI Stream Cipher Device and the DP83223A
TWISTERTM Twisted Pair FDDI Transceiver Device.
For more information on the other devices of the chip set,
consult the appropriate datasheets and application notes.
The DP83266 Media Access Controller and System Interface (MACSI) implements the ANSI X3T9.5 Standard Media
Access Control (MAC) protocol for operation in an FDDI
token ring and provides a comprehensive System Interface.
The MACSI device transmits, receives, repeats, and strips
tokens and frames. It produces and consumes optimized
data structures for efficient data transfer. Full duplex architecture with through parity allows diagnostic transmission
and self testing for error isolation in point-to-point connections.
The MACSI device includes the functionality of both the
DP83261 BMAC device and the DP83265 BSI-2 device with
additional enhancements for higher performance and reliability.
1.1 FDDI 2-CHIP SET
DP83256/56-AP/57 PLAYER a
Device Physical Layer Controller
Features
The PLAYER a device implements the Physical Layer
(PHY) protocol as defined by the ANSI FDDI PHY X3T9.5
standard.
Y
Y
Y
Features
Y
Single chip FDDI Physical Layer (PHY) solution
Y Integrated Digital Clock Recovery Module provides enhanced tracking and greater lock acquisition range
Y Integrated Clock Generation Module provides all necessary clock signals for an FDDI system from an external
12.5 MHz reference
Y Alternate PMD Interface (DP83256-AP/57) supports
UTP twisted pair FDDI PMDs with no external clock recovery or clock generation functions required
Y No External Filter Components
Y Connection Management (CMT) Support (LEM, TNE,
PCÐReact, CFÐReact, Auto Scrubbing)
Y Full on-chip configuration switch
Y Low Power CMOS-BIPOLAR design using a single 5V
supply
Y Full duplex operation with through parity
Y Separate management interface (Control Bus)
Y Selectable Parity on PHY-MAC Interface and Control
Bus Interface
Y Two levels of on-chip loopback
Y 4B/5B encoder/decoder
Y Framing logic
Y Elasticity Buffer, Repeat Filter, and Smoother
Y Line state detector/generator
Y Supports single attach stations, dual attach stations
and concentrators with no external logic
Y DP83256/56-AP for SAS/DAS single path stations
Y P83257 for SAS/DAS single/dual path stations
In addition, the DP83257 contains the additional PHYÐData.request and PHYÐData.indicate ports required for concentrators and dual attach, dual path stations.
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
3
Over 9 Kbytes of on-chip FIFO
5 DMA Channels (2 Output and 3 Input)
12.5 MHz to 33 MHz operation
Full duplex operation with through parity
Real-time VOID frame stripping indicator for bridges
On-chip Address bit swapping capability
32-bit wide Address/Data path with byte parity
Programmable transfer burst sizes of 4 or 8 32-bit
words
Receive frame filtering services
Frame-per-Page mode controllable on each DMA
channel
Demultiplexed Addresses supported on ABus
New multicast address matching
ANSI X3T9.5 MAC standard defined ring service options
Supports all FDDI Ring Scheduling Classes (Synchronous, Asynchronous, etc.)
Supports Individual, Group, Short, Long, and External
Addressing.
Generates Beacon, Claim, and Void frames
Extensive ring and station statistics gathering
Extension for MAC level bridging
Enhanced SBus compatibility
Interfaces to DRAMs or directly to system bus
Supports frame Header/Info splitting
Programmable Big or Little Endian alignment
DP83222 CYCLONE Twisted Pair
FDDI Stream Cipher Device
DP83223A TWISTER High Speed
Networking Transceiver Device
General Description
General Description
The DP83222 CYCLONE Stream Cipher Scrambler/Descrambler Device is an integrated circuit designed to interface directly with the serial bit streams of a Twisted Pair
FDDI PMD. The DP83222 is designed to be fully compatible
with the National Semiconductor FDDI Chip Sets, including
twisted pair FDDI Transceivers, such as the DP83223A
Twisted Pair Transceiver (TWISTER). The DP83222 requires a 125 MHz Transmit Clock and corresponding Receive Clock for synchronous data scrambling and descrambling. The DP83222 is compliant with the ANSI X3T9.5
TP-PMD standard and is required for the reduction of EMI
emission over unshielded media. The DP83222 is specified
to work in conjunction with existing twisted pair transceiver
signalling schemes and enables high bandwidth transmission over Twisted Pair copper media.
The DP83223A Twisted Pair Transceiver is an integrated
circuit capable of driving and receiving either binary or
(MLT-3) encoded datastreams. The DP83223A Transceiver
is designed to interface directly with standards compliant
FDDI, 100BASE-TX or STS-3c ATM chip sets, allowing low
cost data links over copper based media. The DP83223A
allows links of up to 100 meters over both Shielded Twisted
Pair (STP) and datagrade Unshielded Twisted Pair (UTP) or
equivalent. The electrical performance of the DP83223A
meets or exceeds all performance parameters specified
in the ANSI X3T9.5 TP-PMD standard, the IEEE 802.3
100BASE-TX Fast Ethernet Specification and the ATM Forum 155 Mbps Twisted Pair PMD Interface Specification.
The DP83223A also provides important features such as
baseline restoration, TRI-STATEÉ capable transmit outputs,
and controlled transmit output edge rates (to reduce EMI
radiation) for both binary and MLT-3 modes of operation.
Features
Y
Y
Y
Y
Y
Y
Y
Y
Y
Enables 100 Mbps FDDI signalling over Category 5
Unshielded Twisted Pair (UTP) cable and Type 1
Shielded Twisted Pair (STP)
Reduces EMI emissions over Twisted Pair media
Compatible with ANSI X3T9.5 TP-PMD standard
Requires a single a 5V supply
Transparent mode of operation
Flexible NRZ and NRZI format options
Advanced BiCMOS process
Signal Detect and Clock Detect inputs provided for enhanced functionality
Suitable for Fiber Optic PMD replacement applications
Features
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
4
Compliant with ANSI X3T9.5 TP-PMD standard
Compliant with IEEE 802.3 100BASE-TX Ethernet draft
standard
Compliant with ATM Forum 155 Mbps Twisted Pair
Specification
Integrated baseline restoration circuit
Integrated transmitter and receiver with adaptive equalization circuit
Programmable binary or MLT-3 operation
Isolated TX and RX power supplies for minimum noise
coupling
Controlled transmit output edge rates for reduced EMI
TRI-STATE capable current transmit outputs
Loopback feature for board diagnostics
Programmable transmit voltage amplitude
2.0 Architecture Description
The Receiver Block performs the following operations:
2.1 BLOCK OVERVIEW
The PLAYER a device is comprised of six blocks: Clock
# Optionally converts the incoming data stream from NRZI
Recovery, Receiver, Configuration Switch, Transmitter, Station Management (SMT) Support, and Clock Generation
Module as shown in Figure 2-1 .
# Decodes the data from 5B to 4B coding.
# Converts the serial bit stream into 10-bit bytes composed
to NRZ.
of 8 bits data, 1 bit parity, and 1 bit control information.
Clock Recovery
The Clock Recovery Module accepts a 125 Mbps NRZI data
stream from the external PMD receiver. It then provides the
extracted and synchronized data and clock to the Receiver
block.
The Clock Recovery Module performs the following operations:
# Compensates for the differences between the upstream
station clock and the local clocks.
# Decodes Line States.
# Detects link errors.
# Presents data symbol pairs (bytes) to the Configuration
Switch Block.
# Locks to and tracks the incoming NRZI data stream
# Extracts data stream and synchronized 125 MHz clock
Configuration Switch
An FDDI station may be in one of three configurations: Isolate, Wrap or Thru. The Configuration Switch supports these
configurations by switching the transmitted and received
data paths between PLAYER a devices and one or more
MACSI devices.
The configuration switch is integrated into the PLAYER a
device, therefore no external logic is required for this function.
Setting the Configuration switch can be done explicitly via
the Control Bus Interface or it can be set automatically with
the CFÐReact SMT Support feature.
Receiver
During normal operation, the Receiver Block accepts serial
data as inputs at the rate of 125 Mbps from the Clock Recovery Module. During the Internal Loopback mode of operation, the Receiver Block accepts data directly from the
Transmitter Block.
TL/F/11708 – 2
FIGURE 2-1. PLAYER a Device Block Diagram
5
2.0 Architecture Description (Continued)
Transmitter
PMD Interface
The Transmitter Block accepts 10-bit bytes composed of 8
bits data, 1 bit parity, and 1 bit control information from the
Configuration Switch.
The Transmitter Block performs the following operations:
The PMD Interface connects the PLAYER a device to a
standard FDDI Physical Media Connection such as a fiber
optic transceiver or a copper twisted pair transceiver. It is a
125 MHz full duplex serial connection.
The DP83256-AP and DP83257 PLAYER a devices contain
two PMD interfaces. The Primary PMD Interface should be
used for all PMD implementations that do not require an
external scrambler/descrambler function, clock recovery
function, or clock generation function, such as a Fiber Optic
or Shielded Twisted Pair (SDDI) PMD. The second, Alternate PMD Interface can be used to support Unshielded
Twisted Pair (UTP) PMDs that require external scrambling,
and allows implementation with no external clock recovery
or clock generation functions required.
# Encodes the data from 4B to 5B coding.
# Filters out code violations from the data stream.
# Generates Idle, Master, Halt, Quiet, or other user defined
symbol pairs upon request.
# Converts the data stream from NRZ to NRZI format for
transmission.
# Provides smoothing function when necessary.
During normal operation, the Transmitter Block presents serial data to the PMD transmitter. While in Internal Loopback
mode, the Transmitter Block presents serial data to the Receiver Block. While in the External Loopback mode, the
Transmitter Block presents serial data to the Clock Recovery Module.
PHY Port Interface
The PHY Port Interface connects the PLAYER a device to
one or more MAC devices and/or PLAYER a devices. Each
PHY Port Interface consists of two byte-wide interfaces, one
for PHY Request data input to the PLAYER a device and
one for the PHY Indicate data output of the PLAYER a device. Each byte-wide interface consists of a parity bit (odd
parity), a control bit, and two 4-bit symbols.
The DP83257 PLAYER a device has two PHY Port Interfaces while the DP83256 has one PHY Port Interface.
Clock Generation Module
The Clock Generation Module is an integrated phase locked
loop that generates all of the required clock signals for the
PLAYER a device and an FDDI system from a single
12.5 MHz reference.
The Clock Generation Module features:
Control Bus Interface
The Control Bus Interface connects the PLAYER a device
to a wide variety of microprocessors and microcontrollers.
The Control Bus is an asynchronous interface which provides access to 64 8-bit registers which monitor and control
the behavior of the PLAYER a device.
The Control Bus Interface allows a user to:
# Configure SMT features.
# Program the Configuration Switch.
# Enable/disable functions within the Transmitter and Receiver Blocks (i.e., NRZ/NRZI Encoder, Smoother, PHY
Request Data Parity, Line State Generation, Symbol pair
Injection, NRZ/NRZI Decoder, Cascade Mode, etc.).
The Control Bus Interface also can be used to perform the
following functions:
# Monitor Line States received.
# Monitor link errors detected by the Receiver Block.
# Monitor other error conditions.
# High precision clock timing generated from a single
12.5 MHz reference.
# Multiple precision phased (8 ns/16 ns) 12.5 MHz Local
Byte Clocks to eliminate timing skew in large multi-board
concentrator configurations.
# LBC timing which is insensitive to loading variations over
a wide range (20 pF to 70 pF) of LBC loads.
# A selectable dual frequency system clock.
# Low clock edge jitter, due to high VCO stability.
Station Management (SMT) Support
The Station Management Support Block provides a number
of useful features to simplify the implementation of the Connection Management (CMT) portion of SMT.
These features eliminate the time critical CMT response
time constraints imposed by PCÐReact and CFÐReact
times.
Integrated counters and timers eliminate the need for additional external devices.
The following are the CMT features supported:
#
#
#
#
#
#
Clock Interface
The Clock Interface is used to configure the Clock Generation Module and to provide the required clock signals for an
FDDI system.
The following clock signals are generated:
# 5 phase offset 12.5 MHz Local Byte Clocks
# 25 MHz Local Symbol Clock
# 15.625 or 31.25 MHz System Clock
PCÐReact
CFÐReact
Auto Scrubbing (TCF Timer)
Timer, Idle Detection (TID Timer)
Noise Event Counter (TNE Timer)
Link Error Monitor (LEM Counter)
Miscellaneous Interface
The Miscellaneous Interface consists of:
# A reset signal.
# User definable sense signals.
# User definable enable signals.
# Synchronization for cascading PLAYER a devices (a
high-performance non-FDDI mode).
# Device Power and Ground pins.
2.2 INTERFACES
The PLAYER a device connects to other devices via five
functional interfaces: PMD Interface, PHY Port Interface,
Control Bus Interface, Clock Interface, and the Miscellaneous Interface.
6
3.0 Functional Description
The PLAYER a device is comprised of six blocks: Clock
Recovery, Receiver, Transmitter, Configuration Switch,
Clock Generation, and Station Management Support.
DIGITAL PHASE DETECTOR
The Digital Phase Detector has two main functions: phase
error detection and data recovery.
Phase error detection is accomplished by a digital circuit
that compares the input data (PMID) to an internal phaselocked 125 MHz reference clock and generates a pair of
error signals. The first signal is a pulse whose width is equal
to the phase error between the input data and a reference
clock and the second signal is a 4 ns reference pulse.
These signals are fed into the Digital Phase Error Processor
block.
The data recovery function converts the incoming encoded
data stream (PMID) into synchronized data and clock signals. When the circuit is in lock the rising edge of the recovered clock is exactly centered in the recovered data bit cell.
The digital phase detector uses a common path for phase
error detection and data recovery so as to minimize clock
Static Alignment Error (SAE). Phase error averaging is also
included so that phase errors generated by positive and
negative PMID edges equally affect the clock recovery circuit. This greatly improves the immunity to Duty Cycle Distortion (DCD) in the data recovery circuit.
3.1 CLOCK RECOVERY MODULE
The Clock Recovery Module accepts a 125 Mbps NRZI data
stream from the external PMD receiver. It then provides the
extracted and synchronized data and clock to the Receiver
block.
The Clock Recovery Module performs the following operations:
# Locks onto and tracks the incoming NRZI data stream
# Extracts the data stream and the synchronized 125 MHz
clock
The Clock Recovery Module is implemented using an advanced digital architecture that replaces sensitive analog
blocks with digital circuitry. This allows the PLAYER a device to be manufactured to tighter tolerances since it is less
sensitive to processing variations that can adversely affect
analog circuits.
The Clock Recovery Module is comprised of 5 main functional blocks:
Digital Phase Detector
Digital Phase Error Processor
Digital Loop Filter
Digital Phase to Frequency Converter
Frequency Controlled Oscillator
See Figure 3-1 , Clock Recovery Module Block Diagram.
DIGITAL PHASE ERROR PROCESSOR
The Digital Phase Error Processor is responsible for sampling the Phase Detector’s phase error outputs and producing two digital outputs that indicate to the digital loop filter
how to adjust for a difference between the data phase and
reference phases.
The Phase Error Processor is designed to eliminate the effects of different clock edge densities between data symbols and the various line state symbols on the PLL’s loop
gain.
TL/F/11708 – 3
FIGURE 3-1. Clock Recovery Module Block Diagram
7
3.0 Functional Description (Continued)
Each valid Up or Down signal causes a partial 7-bit counter
(using only 96 counts) to increment or decrement at the
O – F converter’s clock rate of 15.625 MHz (250 MHz/16).
When the Data Valid signal is not asserted, the counter
holds count.
The counter value is used to produce 3 triangle waves that
are offset in phase by 120 degrees. This is done with a
special Pulse Density Modulator waveform synthesizer
which takes the place of a traditional Digital-Analog converter. The frequency of the triangle waves tells the Frequency
Controlled Oscillator how much to adjust oscillation. The
phase relationships (leading or lagging) between the 3 signals indicates the direction of change.
The minimum frequency of the triangle waves is 0 and corresponds to the case when the PLL is in perfect lock with
the incoming signal.
The maximum frequency that the O – F converter can produce determines the locking range of the PLL. In this case
the maximum frequency of each triangle wave is 162.76
kHz, which is produced when the O – F converter gets a
continuous count in one direction that is valid every O –F
converter clock cycle of 15.625 MHz (250 MHz/16). The
triangle waves have an amplitude resolution of 48 digital
steps, so a full rising and falling period takes 96 counts
which produces a maximum frequency of 162.76 kHz
(1/(1/15.625 kHz * 96)).
The 96 digital counts of the triangle waves also lead to a
very fine PLL phase resolution of 42 ps (4 ns/96 counts).
This high phase resolution is achieved using very low frequency signals, in contrast to a standard PLL which must
operate at significantly higher frequencies than the data being tracked to achieve such high phase resolution.
Since the loop gain is held constant regardless of the incoming signal edge density, PLL characteristics such as jitter, acquisition rate, locking range etc., are deterministic and
show minimal spread under various operating environments.
The phase error processor also automatically puts the loop
in open-loop-mode when the incoming data stream contains
abnormal low edge rates. When the PLL is in open-loopmode, no update is made to the PLL’s filter variables in the
filter block. The PLL can then use the pretrained frequency
and phase contents to perform data recovery. Since the
loop is implemented digitally, these values (the frequency
and phase variables) are retained. The resolution of the frequency variable is about 1.3 ppm of the incoming frequency.
The resolution of the phase variable is about 40 ps.
DIGITAL LOOP FILTER
The digital loop filter emulates a 1-pole, 1-zero filter and
uses an automatic acquisition speed control circuit to dynamically adjust loop parameters.
The digital loop filter takes the phase error indicator signals
Data Valid and Up/Down from the Phase Error processor
and accumulates errors over a few cycles before passing on
the Data Valid and Up/Down signals to the Phase Error to
Frequency converter.
The filter has 4 sets of bandwidth and damping parameters
which are switched dynamically by an acquisition control
circuit. The input Signal Detect (SD) starts the sequence
and, thereafter, no user programming is required to finish
the sequence.
At the completion of the locking sequence, the loop has the
narrowest bandwidth such that the loop produces minimal
recovered clock jitter. The PLL can track an incoming frequency offset of approximately g 200 ppm. After the acquisition sequence, the equivalent natural frequency of the
loop is reduced to about 7 kHz ( g 56 ppm) of frequency
offset.
The automatic tracking mechanism allows the loop to quickly lock onto the initial data stream for data recovery (typically less than 10 ms) and yet produce very little recovered
clock jitter.
FREQUENCY CONTROLLED OSCILLATOR (FCO)
The frequency controlled oscillator produces a 250 MHz
clock that, when divided by 2, is phase locked to the incoming data’s clock.
The FCO uses three 250 MHz reference clock signals from
the Clock Generation Module and three 0 Hz to 162.76 kHz
error clock signals from the Phase Error to Frequency Converter as inputs. Each signal in a triplet is 120 degrees
phase shifted from the next.
Each corresponding pair (one 250 MHz and one error signal) of signals is mixed together using an amplitude switching modulator, with the error signal modulating the reference. All of the outputs are then summed together to produce the final 250 MHz a fm phase locked clock signal,
where fm is the error frequency.
PHASE ERROR TO FREQUENCY CONVERTER (O – F)
The Phase Error to Frequency Converter takes the Data
Valid and Up/Down signals modified by the Digital Loop
Filter and converts them to triangle waves. The frequency of
the triangle waves is then used to control the Frequency
Controlled Oscillator’s (FCO) 250 MHz oscillations.
8
3.0 Functional Description (Continued)
3.2 RECEIVER BLOCK
During normal operation, the Receiver Block accepts serial
data input at the rate of 125 Mbps from the Clock Recovery
Module. During the Internal Loopback mode of operation,
the Receiver Block accepts input data from the Transmitter
Block.
The Receiver Block performs the following operations:
NRZI TO NRZ DECODER
The NRZI to NRZ Decoder converts Non-Return-To-ZeroInvert-On-Ones data to Non-Return-To-Zero format.
NRZ format data is the natural data format that the receiver
block utilizes internally, so this function is required when the
standard NRZI format data is fed into the device. The receiver block can bypass this conversion function in the case
where an alternate data source outputs NRZ format data.
This function can be enabled and disabled through bit 7
(RNRZ) of the Mode Register (MR). When the bit is cleared,
it converts the incoming bit stream from NRZI to NRZ. This
is the normal configuration required. When the bit is set, the
incoming NRZ bit stream is passed unchanged.
# Optionally converts the incoming data stream from NRZI
to NRZ.
# Decodes the data from 5B to 4B coding.
# Converts the serial bit stream into the National byte-wide
code.
# Compensates for the differences between the upstream
SHIFT REGISTER
The Shift Register converts the serial bit stream into symbol-wide data for the 5B/4B Decoder.
The Shift Register also provides byte-wide data for the
Framing Logic.
station clock and the local clock.
# Decodes Line States.
# Detects link errors.
# Presents data symbol pairs to the Configuration Switch
Block.
The Receiver Block consists of the following functional
blocks:
NRZI to NRZ Decoder
Shift Register
Framing Logic
Symbol Decoder
Line State Detector
Elasticity Buffer
Link Error Detector
See Figure 3-2.
FRAMING LOGIC
The Framing Logic performs the Framing function by detecting the beginning of a frame or the Halt-Halt or Halt-Quiet
symbol pair.
The J-K symbol pair (11000 10001) indicates the beginning
of a frame during normal operation. The Halt-Halt (00100
00100) and Halt-Quiet (00100 00000) symbol pairs are detected for Connection Management (CMT).
TL/F/11708 – 4
FIGURE 3-2. Receiver Block Diagram
9
3.0 Functional Description (Continued)
TABLE 3-1. 5B/4B Symbol Decoding
Framing may be temporarily suspended (i.e. framing hold),
in order to maintain data integrity.
Symbol
Detecting JK
The JK symbol pair can be used to detect the beginning of a
frame during Active Line State (ALS) and Idle Line State
(ILS) conditions.
While the Line State Detector indicates Idle Line State the
receiver ‘‘reframes’’ upon detecting a JK symbol pair and
enters the Active Line State.
During Active Line State, acceptance of a JK symbol (reframing) is allowed for any on-boundary JK which is detected at least 1.5 byte times after the previous JK.
During Active Line State, once reframed on a JK, a subsequent off-boundary JK is ignored, even if it is detected beyond 1.5 byte times after the previous JK.
During Active Line State, an Idle or Ending Delimiter (T)
symbol will allow reframing on any subsequent JK, if a JK is
detected at least 1.5 byte times after the previous JK.
0
1
2
3
4
5
6
7
8
9
A
B
C
D
E
F
Detecting HALT-HALT AND HALT-QUIET
During Idle Line State, the detection of a Halt-Halt, or HaltQuiet symbol pair will still allow the reframing of any subsequent on-boundary JK.
Once a JK is detected during Active Line State, off-boundary Halt-Halt, or Halt-Quiet symbol pairs are ignored until the
Elasticity Buffer (EB) has an opportunity to recenter. They
are treated as violations.
After recentering on a Halt-Halt, or Halt-Quiet symbol pair,
all off boundary Halt-Halt or Halt-Quiet symbol pairs are ignored until the EB has a chance to recenter during a line
state other than Active Line State (which may be as long as
2.8 byte times).
I (Idle)
H (Halt)
JK (Starting
Delimiter)
T (Ending
Delimiter)
R (Reset)
S (Set)
Q (Quiet)
V (Violation)
V
V
V
V
V
V
V
SYMBOL DECODER
The Symbol Decoder is a two level system. The first level is
a 5-bit to 4-bit converter, and the second level is a 4-bit
symbol pair to byte-wide code converter.
The first level latches the received 5-bit symbols and decodes them into 4-bit symbols. Symbols are decoded into
two types: data and control. The 4-bit symbols are sent to
the Line State Detector and the second level of the Symbol
Decoder. See Table 3-1 for the 5B/4B Symbol Decoding
list.
The second level translates two symbols from the 5B/4B
converter and the line state information from the Line State
Detector into the National byte-wide code.
Incoming 5B
Decoded 4B
11110
01001
10100
10101
01010
01011
01110
01111
10010
10011
10110
10111
11010
11011
11100
11101
0000
0001
0010
0011
0100
0101
0110
0111
1000
1001
1010
1011
1100
1101
1110
1111
11111
00100
11000 and
10001
01101
1010
0001
1101
00111
11001
00000
00001
00010
00011
00101
00110
01000
01100
10000
0110
0111
0010
0010
0010
0010
0010
0010
0010
0010
0010
0101
Note: VÊ denotes PHY Invalid or an Elasticity Buffer stuff byte
IÊ denotes Idle symbol in ILS or an Elasticity Buffer stuff byte
LINE STATES DESCRIPTION
Active Line State
The Line State Detector recognizes the incoming data to be
in the Active Line State upon the reception of the Starting
Delimiter (JK symbol pair).
The Line State Detector continues to indicate Active Line
State while receiving data symbols, Ending Delimiter (T
symbols), and Frame Status symbols (R and S) after the JK
symbol pair.
Idle Line State
The Line State Detector recognizes the incoming data to be
in the Idle Line State upon the reception of 2 Idle symbol
pairs nominally (plus up to 9 bits of 1 in start up cases).
Idle Line State indicates the preamble of a frame or the lack
of frame transmission during normal operation. Idle Line
State is also used in the handshake sequence of the PHY
Connection Management process.
LINE STATE DETECTOR
The ANSI X3T9.5 FDDI Physical Layer (PHY) standard
specifies eight Line States that the Physical Layer can
transmit. These Line States are used in the Connection
Management process. They are also used to indicate data
within a frame during normal operation.
The Line States are reported through the Current Receive
State Register (CRSR), Receive Condition Register A
(RCRA), and Receive Condition Register B (RCRB).
10
3.0 Functional Description (Continued)
The Elasticity Buffer will support a maximum clock skew of
50 ppm with a maximum packet length of 4500 bytes.
Super Idle Line State
The Line State Detector recognizes the incoming data to be
in the Super Idle Line State upon the reception of 8 consecutive Idle symbol pairs nominally (plus 1 symbol pair).
The Super Idle Line State is used to insure synchronization
of PCM signalling.
No Signal Detect
The Line State Detector recognizes the incoming data to be
in the No Signal Detect state upon the deassertion of the
Signal Detect signal or lack of internal clock detect from the
Clock Recovery Module, and reception of 8 Quiet symbol
pairs nominally. No Signal Detect indicates that the incoming link is inactive. This is the same as receiving Quiet Line
State (QLS).
Master Line State
The Line State Detector recognizes the incoming data to be
in the Master Line State upon the reception of eight consecutive Halt-Quiet symbol pairs nominally (plus up to 2 symbol
pairs in start up cases).
The Master Line State is used in the handshaking sequence
of the PHY Connection Management process.
Halt Line State
The Line State Detector recognizes the incoming data to be
in the Halt Line State upon the reception of eight consecutive Halt symbol pairs nominally (plus up to 2 symbol pairs in
start up cases).
The Halt Line State is used in the handshaking sequence of
the PHY Connection Management process.
Quiet Line State
The Line State Detector recognizes the incoming data to be
in the Quiet Line State upon the reception of eight consecutive Quiet symbol pairs nominally (plus up to 9 bits of 0 in
start up cases).
The Quiet Line State is used in the handshaking sequence
of the PHY Connection Management process.
Noise Line State
The Line State Detector recognizes the incoming data to be
in the Noise Line State upon the reception of 16 noise symbol pairs without entering any known line state.
The Noise Line State indicates that data is not being received correctly.
Line State Unknown
The Line State Detector recognizes the incoming data to be
in the Line State Unknown state upon the reception of 1
inconsistent symbol pair (i.e. data that is not expected). This
may signify the beginning of a new line state.
Line State Unknown indicates that data is not being received correctly. If the condition persists the Noise Line
State (NLS) may be entered.
To make up for the accumulation of frequency disparity between the two clocks, the Elasticity Buffer will insert or delete Idle symbol pairs in the preamble. Data is written into
the byte-wide registers of the Elasticity Buffer with the Receive Clock, while data is read from the registers with the
Local Byte Clock.
The Elasticity Buffer will recenter (i.e. set the read and write
pointers to a predetermined distance from each other) upon
the detection of a JK or every four byte times during PHY
Invalid (i.e. MLS, HLS, QLS, NLS, NSD) and Idle Line State.
The Elasticity Buffer is designed such that a given register
cannot be written and read simultaneously under normal operating conditions. To avoid metastability problems, the EB
overflow event is flagged and the data is tagged before the
over/under run actually occurs.
LINK ERROR DETECTOR
The Link Error Detector provides continuous monitoring of
an active link (i.e. during Active and Idle Line States) to
insure that it does not exceed the maximum Bit Error Rate
requirement as set by the ANSI standard for a station to
remain on the ring.
Upon detecting a link error, the internal 8-bit Link Error Monitor Counter is decremented. The start value for the Link
Error Monitor Counter is programmed through the Link Error
Threshold Register (LETR). When the Link Error Monitor
Counter reaches zero, bit 4 (LEMT) of the Interrupt Condition Register (ICR) is set to 1. The current value of the Link
Error Monitor Counter can be read through the Current Link
Error Count Register (CLECR). For higher error rates the
current value is an approximate count because the counter
rolls over.
There are two ways to monitor Link Error Rate: polling and
interrupt.
Polling
The Link Error Monitor Counter can be set to a large value,
like FF. This will allow for the greatest time between polling
the register. This start value is programmed through the Link
Error Threshold Register (LETR).
Upon detecting a link error, the Line Error Monitor Counter
is decremented.
The Host System reads the current value of the Link Error
Monitor Counter via the Current Link Error Count Register
(CLECR). The Counter is then reset to FF.
Interrupt
The Link Error Monitor Counter can be set to a small value,
like 5 to 10. This start value is programmed through the Link
Error Threshold Register (LETR).
Upon detecting a link error, the Line Error Monitor Counter
is decremented. When the counter reaches zero, bit 4
(LEMT) of the Interrupt Condition Register (ICR) is set to 1,
and the interrupt signal goes low, interrupting the Host System.
Miscellaneous Items
When bit 0 (RUN) of the Mode Register (MR) is set to zero,
or when the PLAYER a device is reset through the Reset
pin ( E RST), the internal signal detect line is internally
forced to zero and the Line State Detector is set to Line
State Unknown and No Signal Detect.
ELASTICITY BUFFER
The Elasticity Buffer performs the function of a ‘‘variable
depth’’ FIFO to compensate for phase and frequency clock
skews between the Receive Clock (RXC g ) and the Local
Byte Clock (LBC).
Bit 5 (EBOU) of the Receive Condition Register B (RCRB) is
set to 1 to indicate an error condition when the Elasticity
Buffer cannot compensate for the clock skew.
11
3.0 Functional Description (Continued)
While in Internal Loopback mode, the Transmitter Block
presents serial data to the Receiver Block. While in the External Loopback mode, the Transmitter Block presents serial data to the Clock Recovery Module.
The Transmitter Block consists of the following functional
blocks:
Data Registers
Parity Checker
4B/5B Encoder
Repeat Filter
Smoother
Line State Generator
Injection Control Logic
Shift Register
NRZ to NRZI Encoder
See Figure 3-3 , Transmitter Block Diagram.
3.3 TRANSMITTER BLOCK
The Transmitter Block accepts 10-bit bytes consisting of
8 bits data, 1 bit parity, and 1 bit control information, from
the Configuration Switch.
The Transmitter Block performs the following operations:
# Encodes the data from 4B to 5B coding.
# Filters out code violations from the data stream.
# Is capable of generating Idle, Master, Halt, Quiet, or other user defined symbol pairs.
# Converts the data stream from NRZ to NRZI for transmission.
# Serializes data.
During normal operation, the Transmitter Block presents serial data to a PMD transmitter.
TL/F/11708 – 5
FIGURE 3-3. Transmitter Block Diagram
12
3.0 Functional Description (Continued)
TABLE 3-2. 4B/5B Symbol Encoding
DATA REGISTERS
Data from the Configuration Switch is stored in the Data
Registers. The 10-bit byte-wide data consists of a parity bit,
a control bit, and two 4-bit data symbols as shown below.
b9
b8
Parity Bit Control Bit
b7
b0
Data Bits
FIGURE 3-4. Byte-Wide Data
The parity is odd parity. The control bit determines whether
the Data bits represent Data or Control information. When
the control bit is 0 the Data field is interpreted as data and
when it is 1 the field is interpreted as control information
according to the National Semiconductor control codes.
PARITY CHECKER
The Parity Checker verifies that the parity bit in the Data
Register represents odd parity (i.e. odd number of 1s).
The parity is enabled and disabled through bit 6 (PRDPE) of
the Current Transmit State Register (CTSR).
If a parity error occurs, the Parity Checker will set bit 0 (DPE)
in the Interrupt Condition Register (ICR) and report the error
to the Repeat Filter.
4B/5B ENCODER
The 4B/5B Encoder converts the two 4-bit data symbols
from the Configuration Switch into their respective 5-bit
codes.
See Table 3-2 for the Symbol Encoding list.
Symbol
4B Code
5B Code
0
1
2
3
4
5
6
7
8
9
A
B
C
D
E
F
0000
0001
0010
0011
0100
0101
0110
0111
1000
1001
1010
1011
1100
1101
1110
1111
11110
01001
10100
10101
01010
01011
01110
01111
10010
10011
10110
10111
11010
11011
11100
11101
N
0000
JK (Starting
Delimiter)
T (Ending
Delimiter)
R (Reset)
1101
11110 or
11111
11000 and
10001
01101
0100 or
0101
0110
00111
Note: The upper group of symbols are sent with the Control/Data pin set to
Data, while the bottom grouping of symbols are sent with the Control/Data
pin set to Control.
REPEAT FILTER
The Repeat Filter is used to prevent the propagation of
code violations to the downstream station.
Upon receiving violations in data frames, the Repeat Filter
replaces them with two Halt symbol pairs followed by Idle
symbols. Thus the code violations are isolated and recovered at each link and will not be propagated throughout the
entire ring.
13
3.0 Functional Description (Continued)
TL/F/11708 – 6
FIGURE 3-5. Repeat Filter State Diagram
Note: Inputs to the Repeat Filter state machine are shown above the transition lines, while outputs from the state machine are shown below the transition lines.
Note: Abbreviations used in the Repeat Filter State Diagram are shown in Table 3-3.
14
3.0 Functional Description (Continued)
1. In Repeat State, violations cause transitions to Halt State
and two Halt symbol pairs are transmitted (unless JK or Ix
occurs) followed by transition to Idle State.
TABLE 3-3. Abbreviations used in the
Repeat Filter State Diagram
2. When Ix is encountered, the Repeat Filter goes to the Idle
State, during which Idle symbol pairs are transmitted until
a JK is encountered.
3. The Repeat Filter goes to the Repeat State following a JK
from any state.
The END State, which is not part of the FDDI PHY standard,
allows an R or S prior to a T within a frame to be recognized
as a violation. It also allows NT to end a frame as opposed
to being treated as a violation.
FÐIDLE:
Force IdleÐtrue when not in Active
Transmit Mode.
W:
Represents the symbols R, or S, or T
E TPARITY: Parity error
nn :
Data symbols (for C e 0 in the PHY-MAC
interface)
N:
X:
VÊ :
IÊ :
Data portion of a control and data symbol
mixture
Any symbol (i.e. don’t care)
SMOOTHER
The Smoother is used to keep the preamble length of a
frame to a minimum of 6 Idle symbol pairs.
Idle symbols in the preamble of a frame may have been
added or deleted by each station to compensate for the
difference between the Receive Clock and its Local Clock.
The preamble needs to be maintained at a minimum length
to allow stations enough time to complete processing of one
frame and prepare to receive another. Without the Smoother function, the minimum preamble length (6 Idle symbol
pairs) cannot be maintained as several stations may consecutively delete Idle symbols.
The Smoother attempts to keep the number of Idle symbol
pairs in the preamble at 7 by:
Violation symbols or symbols inserted by
the Receiver Block
Idle symbols or symbols inserted by the
Receiver Block
ALSZILSZ:
Active Line State or Idle Line State (i.e.
PHY Invalid)
E ALSZILSZ: Not in Active Line State nor in Idle Line
State (i.e. PHY Valid)
H:
Halt Symbol
R:
Reset Symbol
S:
Set Symbol
T:
Frame ending delimiter
JK:
I:
V:
# Deleting an Idle symbol pair in preambles which have
Frame start delimiter
Idle symbol (Preamble)
Code violations
more than 7 Idle symbol pairs
and/or
# Inserting an idle symbol pair in preambles which have
The Repeat Filter complies with the FDDI standard by observing the following (see Figure 3-5 ):
less than 7 idle symbol pairs (i.e. Extend State).
The Smoother Counter starts counting upon detecting an
Idle symbol pair. It stops counting upon detecting a JK symbol pair.
Figure 3-6 describes the Smoother state diagram.
15
3.0 Functional Description (Continued)
TABLE 3-4. Transmit Modes
LINE STATE GENERATOR
The Line State Generator allows the transmission of the
PHY Request data and can also generate and transmit Idle,
Master, Halt, or Quiet symbol pairs which can be used to
implement the Connection Management procedures as
specified in the FDDI Station Management (SMT) standard
document.
The Line State Generator is programmed through Transmit
bits 0 to 2 (TMk2:0l) of the Current Transmit State Register (CTSR).
Based on the setting of these bits, the Transmitter Block
operates in a Transmit Mode where the Line State Generator overwrites the Repeat Filter and Smoother outputs.
See INJECTION CONTROL LOGIC section for a listing of
the injection Transmit Modes.
Table 3-4 describes the Transmit Modes.
Transit Mode
Behavior
Active Transmit Mode
Transmit data that comes
from Configuration Switch
Off Transmit Mode
Transmit Quiet symbol
pairs and disable the PMD
Transmitter
Idle Transmit Mode
Transmit Idle symbol pairs
Master Transmit Mode
Transmit Halt-Quiet
symbol pairs
Quiet Transmit Mode
Transmit Quiet symbol
pairs
Reserved Transmit Mode
Reserved for future use. If
Mode selected, Quiet
symbol pairs will be
transmitted.
Halt Transmit Mode
Transmit Halt Symbol
pairs
Notes:
TL/F/11708 – 7
SE: Smoother Enable
C: Preamble Counter
FÐIDLE: ForceÐIdle (Stop or ATM)
Xn: Current Byte
Xn–1: Previous Byte
W: RST
FIGURE 3-6. Smoother State Diagram
16
3.0 Functional Description (Continued)
In the One Shot mode, ISRA and ISRB are injected once on
the nth byte after a JK, where n is the programmed value
specified in the Injection Threshold Register.
INJECTION CONTROL LOGIC
The Injection Control Logic replaces the data stream with a
programmable symbol pair. This function is used to transmit
data other than the normal data frame or Line States. The
injection modes can be used for station diagnostic software.
The Injection Symbols overwrite the Line State Generator
(Transmit Modes) and the Repeat Filter and Smoother outputs.
These programmable symbol pairs are stored in the Injection Symbol Register A (ISRA) and Injection Symbol Register B (ISRB). The Injection Threshold Register (IJTR) determines where the Injection Symbol pair will replace the data
symbols.
The Injection Control Logic is programmed through the bits
0 and 1 (ICk1:0l) of the Current Transmit State Register
(CTSR) to one of the following Injection Modes (see Figure
3-7 ):
1. No Injection (i.e. normal operation)
2. One Shot
3. Periodic
4. Continuous
In the No Injection mode, the data stream is transmitted
unchanged.
In the Periodic mode, ISRA and ISRB are injected every nth
symbol.
In the Continuous mode, all data symbols are replaced with
the content of ISRA and ISRB. This is the same as periodic
mode with IJTR e 0.
SHIFT REGISTER
The Shift Register converts encoded parallel data to serial
data. The parallel data is clocked into the Shift Register by
the Local Byte Clock (LBC1), and clocked out by the Transmit Bit Clock (TXC g ) (externally available on the DP83257.)
NRZ TO NRZI ENCODER
The NRZ to NRZI Encoder converts the serial Non-ReturnTo-Zero data to Non-Return-To-Zero-Invert-On-One format.
This function can be enabled and disabled through bit 6
(TNRZ) of the Mode Register (MR). When programmed to
‘‘0’’, it converts the bit stream from NRZ to NRZI. When
programmed to ‘‘1’’, the bit stream is transmitted NRZ.
One Shot (Notes 1,3)
TL/F/11708 – 8
Periodic (Notes 2,3)
TL/F/11708 – 9
Continuous (Note 3)
TL/F/11708 – 10
Note 1: In one shot, when n e 0, the JK is replaced
Note 2: In periodic, when n e 0, all symbols are replaced.
Note 3: Max value on n e 255.
FIGURE 3-7. Injection Modes
17
3.0 Functional Description (Continued)
respective data path. The first two are PHY Port interface
output data paths, AÐIndicate and BÐIndicate, that can
drive output data paths of the external PHY Port interface.
The third output data path is connected internally to the
Transmit Block.
The Configuration Switch is the same on the DP83256 device, the DP83256-AP device, and the DP83257 device.
However, the DP83257 has two PHY Port interfaces connected to the Configuration Switch, whereas the DP83256
and DP83256-AP have one set of PHY port interfaces. The
DP83257 uses the AÐRequest and AÐIndicate paths as
one PHY Port interface and the BÐRequest and BÐIndicate paths as the other PHY Port interface (See Figure 3-8 ).
The DP83256 and DP83256-AP, having one port interface,
use the BÐRequest and AÐIndicate paths as its external
port. The AÐRequest and BÐIndicate paths of the
DP83256 and DP83256-AP are null connections and are not
used by the device (See Figure 3-9 ).
3.4 CONFIGURATION SWITCH
The Configuration Switch consists of a set of multiplexers
and latches which allow the PLAYER a device to configure
the data paths without any external logic. The Configuration
Switch is controlled through the Configuration Register
(CR).
The Configuration Switch has four internal buses: the
AÐRequest bus, the BÐRequest bus, the Receive bus, and
the PHYÐInvalid bus. The two Request buses can be driven by external input data connected to the external PHY
Port interface. The Receive bus is internally connected to
the Receive Block of the PLAYER a device, while the
PHYÐInvalid bus has a fixed 10-bit SMT PHY Invalid connection (LSU) pattern (1 0011 1010), which is useful during
the connection process.
The configuration switch also has three internal multiplexers, each can select any of the four buses to connect to its
TL/F/11708 – 12
FIGURE 3-9. Configuration Switch
Block Diagram for DP83256
and DP83256-AP
TL/F/11708–11
FIGURE 3-8. Configuration Switch
Block Diagram for DP83257
18
3.0 Functional Description (Continued)
Dual Attach Station(DAS)
STATION CONFIGURATIONS
Single Attach Station (SAS)
A Dual Attach Station can be connected directly to the dual
ring, or, optionally to a concentrator. There are two types of
Dual Attach Stations: DAS with a single MAC and DAS with
two MAC layers. See Figure 3-12 and Figure 3-13 .
Two DP83256 or DP83256-AP parts can be connected together to build a Dual Attach Station, however this configuration does not support the optional ThruÐB configuration.
When the optional ThruÐB configuration is desired, it is recommended that the DP83257 be used.
A DAS with a single MAC and two paths can be configured
as follows (see Figure 3-12 ):
The Single Attach Station can be connected to either the
Primary or Secondary ring via a Concentrator. Only 1 MAC
is needed in a SAS.
The DP83256, DP83256-AP, and DP83257 can be used in a
Single Attach Station. The DP83256 and DP83256-AP can
be connected to the MAC via its only PHY Port interface.
The DP83257 can be connected to the MAC via either one
of its 2 PHY Port Interfaces.
See Figure 3-10 and Figure 3-11 .
# B Indicate data of PHYÐA is connected to A Request
input of PHYÐB. BÐRequest input of PHYÐA is connected to A Indicate output of PHYÐB.
# The MAC can be connected to either the A Request input and the A Indicate output of PHYÐA or the B Request input and the B Indicate output of PHYÐB.
A DAS with a single MAC and one path using the DP83256
or DP83256-AP can be configured as follows (see Figure 313 ):
# BÐRequest input of PHYÐA is connected to A Indicate
output of PHYÐB.
# The MAC is connected to the B Request input of
PHYÐB and the AÐIndicate output of PHYÐA.
A DAS with dual MACs can be configured as follows (see
Figure 3-14 ):
# B Indicate data of PHYÐA is connected to A Request
input of PHYÐB. BÐRequest input of PHYÐA is connected to A Indicate output of PHYÐB.
TL/F/11708 – 13
FIGURE 3-10. Single Attach Station
Using the DP83256 or DP83256-AP
# MACÐ1 is connected to the BÐIndicate output and the
BÐRequest Input of PHYÐB.
# MACÐ2 is connected to the AÐIndicate output and the
AÐRequest Input of PHYÐA.
TL/F/11708 – 14
FIGURE 3-11. Single Attachment Station (SAS)
Using the DP83257
19
3.0 Functional Description (Continued)
TL/F/11708 – 15
FIGURE 3-12. Dual Attachment Station (DAS), Single MAC (DP83257)
TL/F/11708 – 16
FIGURE 3-13. Dual Attachment Station (DAS), Single MAC (DP83256/56-AP)
TL/F/11708 – 17
FIGURE 3-14. Dual Attachment Station (DAS), Dual MACs
20
3.0 Functional Description (Continued)
This may require external multiplexers, if used in conjunction with two other MAC layers.
CONCENTRATOR CONFIGURATIONS
There are 2 types of concentrators: Single Attach and Dual
Attach. These concentrators can be designed with or without MAC(s). The configuration is determined based upon its
type and the number of active MACs in the concentrator.
Using the PLAYER a device, a concentrator can be built
with many different configurations without any external logic.
The DP83256, DP83256-AP, and DP83257 can be used to
build a Single Attach concentrator.
See Application Note AN-675, Designing FDDI concentrators and Application Note AN-741, Differentiating FDDI concentrators for further information.
Concepts
A concentrator is comprised of 2 parts: the Dual Ring Connect portion and the Master Ports.
The Dual Ring Connection portion connects the concentrator to the dual ring directly or to another concentrator. If the
concentrator is connected directly to the dual ring, it is a
part of the ‘‘Dual Ring of Trees’’. If the concentrator is connected to another concentrator, it is a ‘‘Branch’’ of the
‘‘Dual Ring of Trees’’.
The Master Ports connect the concentrator to its ‘‘Slaves’’,
or S-class, Single Attach connections. A slave could be a
Single Attach Station or another concentrator (thus forming
another Branch of the Dual Ring Tree).
When a MAC in a concentrator is connected to the primary
or secondary ring, it is required to be situated at the exit port
of that ring (i.e. its PHÐIND is connected to the IND Interface of the last Master Port in the concentrator (PHYÐM n)
that is connected to that ring).
A concentrator can have two MACs, one connected to the
primary ring and one to the secondary ring. In addition, roving MACs can be included in the concentrator configuration.
A roving MAC can be used to test the stations connected to
the concentrator before allowing them to join the dual ring.
Single Attach Concentrator
A Single Attach concentrator is a concentrator that has only
one PHY at the dual ring connect side. It cannot, therefore,
be connected directly to the dual ring. A Single Attach concentrator is a branch to the dual ring tree. It is connected to
the ring as a slave of another concentrator.
Multiple Single Attach concentrators can be connected together hierarchically to build a multiple levels of branches in
a dual ring.
The Single Attach concentrator can be connected to either
the primary or secondary ring depending on the connection
with its concentrator (the concentrator that it is connected
to as a slave).
Figure 3-15 shows a Single Attach concentrator with a single MAC.
Dual Attach Concentrator
A Dual Attach concentrator is a concentrator that has two
PHYs on the dual ring connect side. It is connected directly
to the dual ring and is a part of the dual ring tree.
The Dual Attach concentrator is connected to both the primary and secondary rings.
Dual Attach Concentrator with Single MAC
Figure 3-16 shows a Dual Attach concentrator with a single
MAC.
Because the concentrator has one MAC, it can only transmit
and receive frames on the ring to which the MAC is connected. The concentrator can only repeat frames on the
other ring.
Dual Attach Concentrator with Dual MACs
Figure 3-17 shows a Dual Attach concentrator with dual
MACs.
Because the concentrator has two MACs, it can transmit
and receive frames on both the primary and secondary
rings.
21
3.0 Functional Description (Continued)
TL/F/11708 – 18
FIGURE 3-15. Single Attach Concentrator (SAC), Single MAC
TL/F/11708 – 19
FIGURE 3-16. Dual Attach Concentrator (DAC), Single MAC
TL/F/11708 – 20
FIGURE 3-17. Dual Attach Concentrator (DAC), Dual MACs
22
3.0 Functional Description (Continued)
Another reference clock source option is a local 12.5 MHz
crystal circuit. An example crystal circuit with component
values is shown in Figure 3-19. This circuit is designed to
operate with a crystal that has a CL of 15 pF. The capacitor
values may need to be slightly adjusted for an individual
application to accomodate differences in parasitic loading.
The REFÐSEL signal selects between the two references.
3.5 CLOCK GENERATION MODULE
The Clock Generation Module is an integrated phase locked
loop that generates all of the required clock signals for the
PLAYER a device and the rest of an FDDI system from a
single 12.5 MHz reference.
The Clock Generation Module features:
# High precision clock timing generated from a single
12.5 MHz reference.
# Multiple precision phased (8 ns/16 ns) 12.5 MHz Local
Component Values
Byte Clocks to eliminate timing skew in large multi-board
concentrator configurations.
Crystal:
R:
CISO:
CIN:
COUT:
# LBC timing which is insensitive to loading variations over
a wide range (20 pF to 70 pF) of LBC loads.
12.50000 MHz
270X 5%
56 pF (1%)
54 pF (1%)
54 pF (1%)
# A selectable dual frequency system clock.
# Low clock edge jitter, due to high VCO stability.
The Clock Generation Module is comprised of 6 main functional blocks:
Reference Selector
Phase Comparator
Loop Filter
250 MHz Voltage Controlled Oscillator
Output Phasing and Divide by 10
See Figure 3-18 , Clock Generation Module Block Diagram.
TL/F/11708 – 22
FIGURE 3-19. Crystal Circuit
PHASE COMPARATOR
The Phase Comparator uses two signal inputs: the selected
12.5 MHz reference from the Reference Select Block and a
Local Byte Clock that has been selected for the feedback
input, FBKÐIN. Typically, LBC1 is used as the feedback
clock.
The Phase Comparator generates a pulse of current that is
proportional to the phase difference between the two signals. The current pulses are used to charge and discharge a
control voltage on the internal Loop Filter. This control voltage is used to minimize the phase difference between the
two signals.
REFERENCE SELECTOR
The Reference Selector block allows the user to choose
between 2 sources for the Clock Generation Module’s
12.5 MHz reference clock.
The simplest reference clock source option is to use an
external 12.5 MHz reference signal fed into the REFÐIN
input. This input can come from a crystal oscillator module
or from a Local Byte Clock generated by another PLAYER a
device. Using the appropriate crystal oscillator ensures correct operating frequency without having to adjust any discrete components.
Using an LBC clock from another PLAYER a device allows
one PLAYER a device to create a master clock to which
other PLAYER a devices in a system can be synchronized.
LOOP FILTER
The Loop Filter is a simple internal filter made up of one
capacitor in parallel with a serial capacitor and resistor combination. One end of the filter is connected to Ground and
the other node is driven by the Phase Comparator and controls the internal 250 MHz Voltage Controlled Oscillator.
This node can be examined for diagnostic purposes on the
LPFLTR pin when the FLTREN bit of the CGMREG register
is enabled. The LPFLTR pin is provided for diagnostic purposes only and should not be connected in any application.
TL/F/11708 – 21
FIGURE 3-18. Clock Generation Module Block Diagram
23
3.0 Functional Description (Continued)
The voltage on the Loop Filter is set by the current pulses
generated by the Phase Comparator. The voltage on the
Loop Filter node controls the frequency of the 250 MHz
VCO.
3.6 STATION MANAGEMENT SUPPORT
The Station Management Support Block provides a number
of useful features to simplify the implementation of the Connection Management (CMT) portion of SMT.
These features eliminate the most severe CMT response
time constraints imposed by the PCÐReact and CFÐReact
times. The many integrated counters and timers also eliminate the need for additional external devices.
The following CMT features are supported:
250 MHZ VOLTAGE CONTROLLED OSCILLATOR (VCO)
The internal Voltage Controlled Oscillator is a low gain VCO
whose primary frequency of oscillation centers around
250 MHz. The VCO produces little clock jitter due to its
exceptional stability under all circumstances.
The VCO’s output frequency is proportional to the voltage
on the Loop Filter node.
#
#
#
#
#
#
OUTPUT PHASING
The Output Phasing block is a precision clock division circuit
that produces clock signals of 4 distinct frequencies. Within
the 12.5 MHz frequency, 5 clock signals with selectable 8 ns
or 16 ns phase difference are produced.
The following clock signals are produced:
System Clock (CLK16/CLK32)
Local Symbol Clock (LSC)
Local Byte Clocks 1–5 (LBCn) (Divide by 10)
System Clock (CLK16/CLK32)
The System Clock is provided as an extra set of clock frequencies that may be used as a clock for non-FDDI chipset
portions of a system or as a higher frequency System Interface clock for the MACSI device. This clock is derived by
dividing the 125 MHz clock by 8 or 4 times.
The frequency is selectable through the CLKSEL bit of the
MODE2 register. The output has built-in glitch suppression
so that changing the CLKSEL bit will not result in glitches
appearing at the output.
Local Symbol Clock (LSC)
The Local Symbol Clock is a 40% HIGH/60% LOW duty
cycle clock provided for use by the MACSI device and any
external logic that needs to be synchronized to the Symbol
timing.
This clock is derived by dividing the 125 MHz clock by 5.
Local Byte Clocks 1–5 (LBCn)
The Local Byte Clocks are provided for use by the MACSI
device, by any external logic that needs to be synchronized
to the Byte timing, and for use in concentrators to synchronize the timing between multiple PLAYER a devices.
These clocks are derived by dividing the 125 MHz clock by
10. The different phase relationships between the LBCs are
achieved by tapping off of different outputs of a Johnson
counter inside the Output Phasing block.
The phase relationship (separation by 8 ns or 16 ns) of the
LBCs is selected using the PHÐSEL pin.
One of the LBCs must be used as the source of the feedback input, FBKÐIN, which requires a 12.5 MHz frequency.
When the PLAYER a device is using a crystal as a reference it does not matter which LBC is used as the feedback
input. Typically the least loaded LBC is used. However,
when using an external reference that is supplied by another PLAYER a device, it is important to select the LBC that
keeps your system properly synchronized. Typically, all devices will use LBC1 as the feedback input.
PCÐReact
CFÐReact
Auto Scrubbing (TCF Timer)
Timer, Idle Detection (TID Timer)
Noise Event Counter (TNE Timer)
Link Error Monitor (LEM Counter)
PCÐREACT
PCÐReact is one of the timing restrictions imposed by Connection Management (CMT). It is one of the two most critical timing restrictions imposed (the other being CFÐReact.)
The ANSI SMT standard states that ‘‘PCÐReact is the maximum time for PCM [Physical Connection Management] to
make a state transition to PCÐBreak when QLS, a fault
condition, or PCÐStart signal is present. This maximum
time also places a limit on the time to react to a PCÐStop
signal. This limitation does not apply to any other PCM transitions.’’ PCÐReact puts a sharp time limit on how long it
takes to transition to the PCÐBreak state and transmit the
correct line state when a PCÐBreak transition is required.
The range for the timer is PCÐReact s 3.0 ms and has a
default value equal to 3.0 ms.
The PLAYER a device contains a Trigger Definition Register and a set of CMT Condition Registers that can be used
to satisfy the PCÐReact timing.
The Trigger Definition Register (TDR) controls two functions. First, it allows the selection of the line state(s) on
which to trigger (SILS, MLS, HLS . . . ). For PCÐReact, the
line states used would be the ones that caused a transition
to the PCÐBreak state from the current PCM state.
Second, it allows specification of a line state to be transmitted when the trigger condition is met. For PCÐReact, this is
the line state that needs to be transmitted when a transition
to the PCÐBreak state occurs, which is Quiet Line State
(QLS).
The set of CMT Condition registers controls interrupt generation when a trigger condition occurs. The CMT Condition
Register set includes a CMT Condition Register (CMTCR), a
CMT Condition Comparison Register (CMTCCR), and a
CMT Condition Mask Register (CMTCMR).
Line state triggering for PCÐReact is enabled by selecting
line states to trigger on from the Trigger Definition Register
(TDR) bits 3-7.
The Trigger Condition Occurred (TCO) bit of the CMTCR is
automatically set when the trigger condition specified by the
TDR register is met.
The line state specified by the Trigger Definition Register
(TDR) bits 0 – 2 is then loaded into the Current Transmit
Mode Register (CTSR), causing the line state to be transmitted.
24
3.0 Functional Description (Continued)
If the TCO Mask (TCOM) bit of the CMTCMR is set, then
whenever the CMTCR.TCO bit becomes set the Receive
Condition Register B’s Connection Service Event
(RCRB.CSE) bit will be set. This allows an interrupt to be
generated for the trigger event.
As an example, suppose the PCM state machine is in the
ACTIVE state. From this state, if a Halt Line State (HLS) or
Quiet Line State (QLS) is detected, or the Noise Threshold
is reached, the state machine must move to the PCÐBreak
state and begin transmitting QLS. To implement this behavior when the PCÐACTIVE state is entered, set
TDR.TTM2–0 to 110 (Quiet Transmit), set TDR.TOHLS,
TDR.TOQLS, and TDR.TONT and reset all other bits (TOSILS and TOMLS). Also set CMTCMR.TCOM if an interrupt
is desired.
AUTO SCRUBBING
Auto Scrubbing is an additional CMT feature that further
enhances the automatic configuration switch setting in order to meet the CFÐReact timing. When enabled, Auto
Scrubbing causes 2 PHYÐInvalid symbols followed by
Scrub Symbol pairs (Idles) to be sourced for a user selectable duration (the scrubbing time) after a trigger condition
(the same one used for PCÐReact and CFÐReact) occurs
and prior to a change in the configuration switch setting on
all indicate ports that will be changed.
Auto Scrubbing is enabled by setting the Enable Scrubbing
on Trigger Conditions (ESTC) bit of Mode Register 2
(MODE2).
The Scrub Timer Threshold Register (STTR) defines the duration of the scrubbing, which can last up to approximately
10ms. The Scrub Timer Value Register (STVR) can be used
to examine a snapshot of the upper 8 bits of the STTR
register.
CFÐREACT
CFÐReact is one of the timing restrictions imposed by Connection Management (CMT). It is one of the two most critical timing restrictions imposed (the other being
PCÐReact).
The ANSI SMT standard states that ‘‘CFÐReact is the maximum time for CFM [Configuration Management] to reconfigure to remove a non-Active connection from the token
path.’’
The range for the timer is CFÐReact s 3.0 ms and has a
default value equal to 3.0 ms.
The PLAYER a device contains a Trigger Transition Configuration Register and a set of CMT Condition Registers that
can be used to satisfy the CFÐReact timing.
he Trigger Transition Configuration Register (TTCR) holds
the new configuration switch settings to be loaded into the
Configuration Register (CR) when a trigger condition occurs.
Enabling line state triggering with the Trigger Definition Register (TDR) bits 3–7 also enables the CFÐReact response.
This means that whenever trigger conditions are actively
used for PCÐReact, the value of the TTCR register will be
used also. This implies that it either must always then be
loaded with the current configuration setting, causing no
change to the CR, or it must be loaded with the appropriate
value to accommodate the CFÐReact function.
The Trigger Transition Configuration Register (TTCR) must
be set the configuration desired when the trigger condition
occurs. When the trigger condition occurs the value of this
register is loaded into the Configuration Register (CR). During this time writes to the CR are inhibited.
To continue the example from the PCÐReact description,
suppose that when in the ACTIVE state for the PCM state
machine, the CFM state machine is also in the THRUÐA
state. If trigger conditions are enabled via the
CMTCMR.TCOM bit and it is desired to not implement CFÐ
React, TTCR must be set to the present value of CR. If it is
desired to not implement CFÐReact then TTCR should be
set to the value which would change the configuration to the
WRAP state. The wrap conditions WRAPÐA or WRAPÐB
depend on which PHY gets reconfigured.
TIMER, IDLE DETECTION
The Idle Detection Timer is required to flag the continued
presence of the Idle Line State for a duration of 8 Idle Symbol pairs plus 1 symbol pair.
This feature is implemented in the Receiver Block by the
Super Idle Line State (SILS).
NOISE EVENT COUNTER
The Noise Event Counter can be used to time the duration
between Noise Events (which are described in detail below)
and to count frame sizes. The first feature is the most often
recognized, but the second is often overlooked and can
lead to potential difficulty if not properly set.
The Noise Event Counter is implemented as a pair of down
counters: one the actual Noise Counter and the other a
Noise Counter Prescaling value. The Noise Threshold Register (NTR) and the Noise Prescale Threshold Register
(NPTR) can be programmed to the counter’s initial value
while the Current Noise Count Register (CNCR) and the
Current Noise Prescale Count Register (CNPCR) provide a
snapshot of the actual counter.
The Noise Event Counter decrements whenever a Noise
Line State (NLS), Line State Unknown (LSU), or Active Line
State (ALS) is received and has its start value reloaded
whenever it receives Halt Line State (HLS), Idle Line State
(ILS), Master Line State (MLS), Quiet Line State (QLS), or
No Signal Detect (NSD). The Noise Event Counter is also
reset for a Start or End Delimiter. This means the Noise
counter increments for bad events as well as for every data
symbol in a frame. Should the Noise Counter expire, it indicates that a new line state (including ALS) has not been
entered for NTÐMAX time. This indicates that either a
frame is too long or that noise is being received.
For this reason it is important to choose a value for the
counter that is larger than the longest frame of 4500 bytes.
The ANSI SMT specification recommends a value for
NTÐMAX of 1.3ms for the noise threshold.
A Noise Event is defined as follows:
A noise event is a noisebyte, or a byte of data which is not in
line with the current line state, indicating error or corruption.
25
3.0 Functional Description (Continued)
TABLE 3-5. Noise Event Description
Noise Event e
LINK ERROR MONITOR
Link Error Monitoring is accomplished in the PLAYER a device through the Link Error Monitor Counter. The initial value
of this down counter is set using the Link Error Threshold
Register (LETR). A snapshot of the counter can be taken
with the Current Link Error Count Register (CLECR).
A Link Error is defined as follows:
[SD # E CD] a
[SD # CD # PI # E (II a JK a AB)] a
[SD # CD # E PI # (PB e II) # AB]
Where:
#
a
E
SD
CD
PB
PLS
PI
e Logical AND
e Logical OR
e Logical NOT
TABLE 3-6. Link Error Event Description
Link Error
Event e
Signal Detect
Clock Detect
Previous Byte
Previous Line State
PHY Invalid e HLS a QLS
MLS a NLS a ÀULS # [PLS
(ALS a ILS)] Ó
Idle Line State
Active Line State
Unknown Line State
Halt Line State
Quiet Line State
Master Line State
Noise Line State
Unknown Line State
ILS
ALS
ULS
HLS
QLS
MLS
NLS
ULS
e
e
e
e
e
a
e
e
e
e
e
e
e
e
e
I
J
K
e Idle symbol
e First symbol of start delimiter
e Second symbol of start
R
S
T
A
B
n
delimiter
e Reset symbol
e Set symbol
e End Delimiter
enaRaSaT
enaRaSaTaI
e any data symbol
[ALS # (I E I a xV a Vx a H E H)] a
[ALS # E SD] a [ILS # E (II a JK)] a
[ILS # E SD)] a [ULS # (PLS e ALS) #
LinkÐErrorÐFlag # E SB # E (HH a HI
a II a JK)]
Set LinkÐErrorÐFlag e [ALS # (HH a NH a RH a
SH a TH)]
Clear LinkÐErrorÐFlag e [ALS # JK] a
[ILS # JK] a [ULS # (PLS e ALS # LinkÐ
ErrorÐFlag # E SB # E (HH a HI a II a
JK)]
Where:
E
a
#
ILS
ALS
ULS
x
I
H
J
K
V
R
S
T
N
PLS
SD
SB
26
Logical NOT
Logical OR
Logical AND
Idle Line State
Active Line State
Unknown Line State
Any symbol
Idle symbol
Halt symbol
First symbol of start delimiter
Second symbol of start
delimiter
e Violation symbol
e Reset symbol
e Set symbol
e End delimiter symbol
e Data symbol converted to
0000 by the PLAYER a device
Receiver Block in symbol pairs
that contain a data and a control
symbol
e Previous Line State
e Signal Detect
e Stuff Byte: Byte inserted by EB
before a JK symbol pair for
recentering or due to off-axis JK
e
e
e
e
e
e
e
e
e
e
e
3.0 Functional Description (Continued)
3.7 PHY-MAC INTERFACE
to be in the Active Line State upon reception of the Starting
Delimiter (JK symbol pair).
NATIONAL BYTE-WIDE CODE
During Idle Line State any non Idle symbols will be reflected
as the code IÊ uILS. If both symbols received during Idle Line
State are Idle symbols, then the Symbol Decoder generates
IÊ kILS as its output. Note the coded Known/Unknown Bit
(b3) and the Last Known Line State (b2 – 0). The Receive
State is 4 bits long and it represents either the PHY Invalid
(0011) or the Idle Line State (1011) condition. The Known/
Unknown Bit shows if the symbols received match the line
state information in the last 3 bits.
During any line state other than Idle Line State or Active
Line State, the Symbol Decoder generates the code VÊ kLS
if the incoming symbols match the current line state. The
symbol decoder generates VÊ uLS if the incoming symbols
do not match the current line state.
The PLAYER a device outputs the National byte-wide code
from its PHY Port Indicate Output to the MAC device. Each
National byte-wide code may contain data or control codes
or the line state information of the connection. Table 3-7
lists all the possible outputs.
During Active Line State all data and control symbols are
being repeated to the PHY Port Indicate Output with the
exception of data in data-control mixture bytes. That data
symbol is replaced by zero. If only one symbol in a byte is a
control symbol, the data symbol will be replaced by 0000
and the whole byte will be presented as control code. Note
that the Line State Detector recognizes the incoming data
TABLE 3-7. National Byte Wide Code
Symbol 1
Current Line State
ALS
ALS
ALS
ALS
ILS
ILS
ILS
ILS
Stuff Byte during ILS
Not ALS and Not ILS
Not ALS and Not ILS
Not ALS and Not ILS
Not ALS and Not ILS
Stuff Byte during Not ALS
Symbol 2
Data
Control Bit
Data
Control Bit
Data
0
0
1
1
1
1
x
x
x
1
1
x
x
x
n
n
C
C
I
I
Not I
Not I
x
M
M
Not M
Not M
x
0
1
0
1
1
x
1
x
x
1
x
1
x
x
n
C
n
C
I
Not I
I
Not I
x
M
Not M
M
Not M
x
0
1
1
1
1
1
1
1
1
1
1
1
1
1
n-n
N-C
C-N
C-C
IÊ -k-LS
IÊ -u-LS
IÊ -u-LS
IÊ -u-LS
IÊ -k-ILS
VÊ -k-LS
VÊ -u-LS
VÊ -u-LS
VÊ -u-LS
VÊ -k-LS, VÊ -u-LS
or LÊ -u-ILS
0011 1011
0011 1010
1011 1000
EB Overflow/Underflow
SMTÐPI Connection (LSU)
Scrub Symbol Pair
1
1
1
Where:
n e Any data symbol in À0, 1, 2 . . . F Ó
C
N
I
M
IÊ
VÊ
LS
u
k
x
National Code
Control Bit
e Any control symbol in À V, R, S, T, I, H Ó
e 0000 e Code for data symbol in a data control mixture byte
e Idle Symbol
e Any symbol that matches the current line state
e 1011 e First symbols of the byte in Idle Line State
e 0011 e PHY Invalid
e Line State
ALS e 000
ILS e 001
NSD e 010
MLS e 100
HLS e 101
QLS e 110
NLS e 111
e1
e Indicates symbol received does not match current line state
e0
e Indicate symbol received matches current line state
e Don’t care
27
3.0 Functional Description (Continued)
National Byte-Wide Code Example
Incoming 5B Code
98765
43210
11111
11111
11111
11111
11111
Decoded 4B Code
C
3210
C
3210
(II)
1
1010
1
1010
(II)
1
1010
1
1010
11111
(II)
1
1010
1
11000
10001
(JK)
1
1101
–––-
–––-
(xx)
0
–––-
–––-
(xx)
0
–––-
–––-
(xx)
National Byte-Wide Code (w/o parity)
C
7654
3210
(II)
1
1011
0001
(IÊ -k-ILS)*
(II)
1
1011
0001
(IÊ -k-ILS)
1010
(II)
1
1011
0001
(IÊ -k-ILS)
1
1102
(JK)
1
1101
1101
(JK Symbols)
–––
0
–––
(xx)
0
–– –
–– –
(Data Symbols)
–––
0
–––
(xx)
0
–– –
–– –
(Data Symbols)
0
–––
0
–––
(xx)
0
–– –
–– –
(Data Symbols)
(More data Ð)
–––-
–––-
(xx)
0
–––
0
–––
(xx)
0
–– –
–– –
(Data Symbols)
–––-
–––-
(xx)
0
–––
0
–––
(xx)
0
–– –
–– –
(Data Symbols)
–––-
–––-
(xx)
0
–––
0
–––
(xx)
0
–– –
–– –
(Data Symbols)
01101
00111
(TR)
1
0101
1
0110
(TR)
1
0101
0110
(T and R Symbols)
00111
00111
(RR)
1
0110
1
0110
(RR)
1
0110
0110
(Two R Symbols)
11111
11111
(II)
1
1010
1
1010
(II)
1
1010
1010
(Idle Symbols)
11111
11111
(II)
1
1010
1
1010
(II)
1
1010
1010
(Idle Symbols)
11111
11111
(II)
1
1010
1
1010
(II)
1
1011
0001
(IÊ -k-ILS)
11111
11111
(II)
1
1010
1
1010
(II)
1
1011
0001
(IÊ -k-ILS)
11111
11111
(II)
1
1010
1
1010
(II)
1
1011
0001
(IÊ -k-ILS)
00100
00100
(HH)
1
0001
1
0001
(HH)
1
1011
1001
(IÊ -u-ILS)
00100
00100
(HH)
1
0001
1
0001
(HH)
1
1011
1001
(IÊ -u-ILS)
00100
00100
(HH)
1
0001
1
0001
(HH)
1
1011
1001
(IÊ -u-ILS)
00100
00100
(HH)
1
0001
1
0001
(HH)
1
1011
1001
(IÊ -u-ILS)
00100
00100
(HH)
1
0001
1
0001
(HH)
1
1011
1001
(IÊ -u-ILS)
00100
00100
(HH)
1
0001
1
0001
(HH)
1
1011
1001
(IÊ -u-ILS)
00100
00100
(HH)
1
0001
1
0001
(HH)
1
1011
1001
(IÊ -u-ILS)
00100
00100
(HH)
1
0001
1
0001
(HH)
1
0011
0101
(VÊ -k-HLS)
00100
00100
(HH)
1
0001
1
0001
(HH)
1
0011
0101
(VÊ -k-HLS)
00100
00100
(HH)
1
0001
1
0001
(HH)
1
0011
0101
(VÊ -k-HLS)
11111
11111
(II)
1
1010
1
1010
(II)
1
0011
1101
(VÊ -u-HLS)
11111
11111
(II)
1
1010
1
1010
(II)
1
1011
0001
(IÊ -k-ILS)
11111
11111
(II)
1
1010
1
1010
(II)
1
1011
0001
(IÊ -k-ILS)
*Assume the receiver is in the Idle Line State.
28
3.0 Functional Description (Continued)
or clock generation function, such as a Fiber Optic or
Shielded Twisted Pair (SDDI) PMDs. The second, Alternate
PMD Interface can be used to support Unshielded Twisted
Pair (UTP) PMDs that require external scrambling, and allows implementation with no external clock recovery or
clock generation functions required. See Figure 3-21.
PLAYER a TO PMD CONNECTIONS
The following figures illustrate how the PLAYER a device
can be connected to various types of PMDs.
3.8 PMD INTERFACE
The PMD Interface connects the PLAYER a device to a
standard FDDI Physical Media Connection such as a fiber
optic transceiver or a copper twisted pair transceiver. It is a
125 MHz full duplex serial connection.
The DP83256 PLAYER a device contains one PMD interface. This PMD Interface should be used for all PMD implementations that do not require an external scrambler/
descrambler function, clock recovery function, or clock
generation function, such as a Fiber Optic or Shielded
Twisted Pair (SDDI) PMDs.
The DP83256-AP and DP83257 PLAYER a devices contain
two PMD interfaces. The PMD Interface should be used for
all PMD implementations that do not require an external
scrambler/descrambler function, clock recovery function,
Figure 3-20 shows how the DP83256, DP83256-AP, or
DP83257 PLAYER a device is connected to a Fiber Optic
or Shielded Twisted Pair (SDDI) PMD using the Primary
PMD Interface.
Figure 3-21 shows how the DP83256-AP or DP83257
PLAYER a device is connected to an Unshielded Twisted
Pair (UTP) PMD using the Alternate PMD Interface.
TL/F/11708 – 47
FIGURE 3-20. Fiber Optic or STP PMD Connection
TL/F/11708 – 48
FIGURE 3-21. UTP PMD Connections
29
3.0 Functional Description (Continued)
in the CGMREG register. The transmit clocks are disabled
by default and should be left that way unless it is being
used.
INTERFACE ACTIVATION
The Primary PMD Interface is always enabled.
The Alternate PMD Interface is enabled by programming a
PLAYER a register bit. To enable the interface, write a 1 to
the APMDEN bit in the APMDREG register. The interface is
off by default and should be left that way unless it is being
used.
It will also probably be necessary to enable the Transmit
Clocks when using the Alternate PMD Interface. The Transmit Clocks (TXC) are enabled by writing a 1 to the TXCE bit
Note that when the Alternate PMD Interface is active, the
Primary PMD Interface can not be used without the Alternate PMD Interface connections. Also note that the Long
Internal Loopback (LILB) can not be used when the Alternate PMD Interface is activated.
30
4.0 Modes of Operation
The PLAYER a device can operate in 4 basic modes: RUN,
STOP, LOOPBACK, and CASCADE.
4.1 RUN MODE
RUN is the normal mode of operation.
In this mode, the PLAYER a device is configured to be connected to the media via the PMD transmitter and PMD receiver at the PMD Interface. It is also connected to any
other PLAYER a device(s) and/or MACSI device(s) via the
Port A and Port B Interfaces.
While operating in the RUN mode, the PLAYER a device
receives and transmits Line States (Quiet, Halt, Master, Idle)
and frames (Active LIne State).
4.2 STOP MODE
The PLAYER a device operates in the STOP mode while it
is being initialized or configured.
The PLAYER a device is also reset to the STOP mode automatically when the E RST pin is set to ground.
When in STOP mode, the PLAYER a device performs the
following functions:
#
#
#
#
#
#
#
Resets the Repeat Filter.
Resets the Smoother.
Resets the Receiver Block Line State Counters.
Resets the Clock Recovery Module
Flushes the Elasticity Buffer.
Forces Line State Unknown in the Receiver Block.
Outputs PHY Invalid condition symbol pairs through the
PHY Data Indicate pins (AIP, AIC, AIDk7:0l, BIP, BIC,
BIDk7:0l), when port is enabled.
TL/F/11708 – 23
FIGURE 4-1. Configuration Switch Loopback
for DP83257
# Outputs Quiet symbol pairs through the PMD Data Request pins (PMRD g ).
4.3 LOOPBACK MODE
The PLAYER a device provides 3 types of loopback tests:
Configuration Switch Loopback, Short Internal Loopback,
and Long Internal Loopback. These Loopback modes can
be used to test different portions of the device.
Configuration Switch Loopback
The Configuration Switch Loopback can be used to test the
data paths of the MACSI device(s) that are connected to the
PLAYER a device before transmitting and receiving data
through the network.
In the Configuration Switch Loopback mode, the PLAYER a
device Configuration Register (CR) can be programmed to
perform the following functions:
# Select Port A PHY Request Data, Port B PHY Request
Data, or PHY Invalid to connect to Port A PHY Indicate
Data via the AÐIND Mux.
# Select Port A PHY Request Data, Port B PHY Request
Data, or PHY Invalid to connect to Port B PHY Indicate
Data via the BÐIND Mux.
# Connect data from the Receiver Block to the Transmitter
Block via the TransmitterÐMux. (The PLAYER a device
is repeating incoming data from the media in the Configuration Switch Loopback mode.)
See Figure 4-1 and Figure 4-2.
TL/F/11708 – 24
FIGURE 4-2. Configuration Switch Loopback
for DP83256 and DP 83256-AP
31
4.0 Modes of Operation (Continued)
# Ignores the PMD Data Indicate pins (PMID g ),
# Outputs Quiet symbols through the PMD Data Request
Short Internal Loopback
The Short Internal Loopback mode can be used to test the
functionality of the PLAYER a device, not including the
Clock Recovery function, and to test the data paths between the PLAYER a device and MACSI devices before
ring insertion.
When in the Short Internal Loopback mode, the PLAYER a
device performs the following functions:
# Directs the output data of the Transmitter Block to the
input of the Receiver Block through an internal path.
pins (PMRD g ).
The level of the Quiet symbols transmitted through the
PMRD g pins during loopback is automatically set to the
transmitter off level.
If both Short Internal Loopback and Long Internal Loopback
modes are selected, Long Internal Loopback mode will
have priority over Short Internal Loopback mode. This is the
longest loopback path within the PLAYER a device.
See Figure 4-3 , Short Internal Loopback.
TL/F/11708 – 25
FIGURE 4-3. Short Internal Loopback
32
4.0 Modes of Operation (Continued)
# Ignores the PMD Data Indicate pins (PMID g ),
# Outputs Quiet symbols through the PMD Data Request
Long Internal Loopback
The Long Internal Loopback mode implements the longest
loopback path that is completely within the PLAYER a device.
The Long Internal Loopback mode can be used to test the
functionality of the PLAYER a device, including the Clock
Recovery function, and to test the data paths between the
PLAYER a device and MACSI devices before ring insertion.
When in the Long Internal Loopback mode, the PLAYER a
device performs the following functions:
# Directs the output data of the Transmitter Block to the
input of the Clock Recovery Module through an internal
path.
pins (PMRD g ).
The level of the Quiet symbols transmitted through the
PMRD g pins during loopback is automatically set to the
transmitter off level.
If both Short Internal Loopback and Long Internal Loopback
modes are selected, Long Internal Loopback mode will
have priority over Short Internal Loopback mode. This is the
longest loopback path within the PLAYER a device.
Note that the LILB path is disconnected and should not be
used when the Alternate PMD Interface is active.
See Figure 4-4 , Long Internal Loopback.
TL/F/11708 – 26
FIGURE 4-4. Long Internal Loopback
33
4.0 Modes of Operation (Continued)
Reference Select Reset occurs when the PLAYER a device’s REFÐSEL pin is switched from using the REFÐIN
input to using a crystal with the XTALÐIN and XTALÐOUT
pins. This is the same as a Power Up Reset and is done
because the crystal is going from a dead stop to an active
state when REFÐSEL is switched. This reset, like the Power Up Reset, takes about 10 ms from the falling edge of
REFÐSEL.
Stop Mode is activated by writing a 0 to the RUN bit in the
Mode Register. Stop Mode is a selective reset that resets
the Clock Recovery Module and portions of the Player Module.
Changes from Revision A to Revision B:
The previous descriptions describe the reset logic in the
revision B PLAYER a device. Two changes were made to
the original revision A PLAYER a device reset logic.
First, the Hardware Reset was shortened by eliminating the
requirement of having to wait for the crystal to settle before
letting the Clock Generation Module try to lock to the crystal. This behavior is correct because the PLAYER a device
has already waited for the crystal to settle once during the
Power Up Reset. The revision A PLAYER a follows a Power
Up Reset cycle when Hardware Reset is activated.
Second, a full Power Up Reset is now done when the clock
reference is switched to the crystal. This is necessary to
allow the crystal time to start up when it is switched to from
the REFÐIN input. This reset is not performed on the revision A PLAYER a .
Recommendations:
The following are some recommendations for using the reset mechanisms of the PLAYER a most effectively:
1. Always wait a minimum of 10 ms after power-up before
doing anything to the PLAYER a device. 10 ms is a minimum, it may be desirable to wait longer if the system
power supply or clock reference has not stabilized by this
time.
2. Always use the Hardware Reset to reset the PLAYER a
device after Power Up. This should be done after the
initial Power Up waiting period of at least 10 ms.
4.4 DEVICE RESET
The revision B PLAYER a device has five different levels of
device ResetÐPower Up Reset, Hardware Reset, Player
Reset, Reference Select Reset, and Stop Mode. The Resets can be used to return the whole device or a portion of
the device to its default configuration.
Power Up Reset begins automatically when power is first
applied to the PLAYER a device and reaches a certain voltage level. Power Up Reset affects all of the modules in the
PLAYER a device, specifically the Clock Generation Module (CGM), Clock Recovery Module (CRM), and the Player
Module, returning each module to its default configuration.
This reset begins by waiting for the crystal to stabilize, then
the CGM PLL proceeds to lock to the crystal and the rest of
the PLAYER a device is reset. This reset takes the longest
amount of time at approximately 10 ms from the time the
PLAYER a device’s power supply reaches 4.4V. Even
though the Power Up Reset is usually effective, due to the
variation in the start-up conditions of a systems power supply, the Power Up Reset trigger can not be guaranteed to
operate correctly. Therefore, a Hardware Reset should always be performed on the PLAYER a after waiting a minimum of 10 ms for the Power Up Reset to complete its reset
attempt.
Hardware Reset occurs at the rising edge of PLAYER a
device’s E RST pin. Hardware Reset affects all of the modules in the PLAYER a device, specifically the CGM, CRM
and the Player Module, returning each module to its default
configuration. During Hardware Reset it is not necessary to
force the Clock Generation Module to wait for the crystal to
settle again at this time because it has settled in the time
since the initial reset at power up. This reset takes the second longest amount of time at approximately 1 ms from the
rising edge of E RST.
Player Reset is activated by writing a 1 to the PHYRST bit in
Mode Register 2. Player Reset only affects the Player Module. This reset is the shortest and only takes about 3 ms
from the completion of the register write. The device should
not be accessed by the Control Bus during this reset.
34
4.0 Modes of Operation (Continued)
# Data frames must be a minimum of three bytes long
4.5 CASCADE MODE
The PLAYER a device can operate in the Cascade (parallel) mode (Figure 4-5) which is used in high bandwidth,
point-to-point data transfer applications. This is a non-FDDI
mode of operation. This is only available on the DP83257
device.
Concepts
In the Cascade mode, multiple PLAYER a devices are connected together to provide data transfer at multiples of the
FDDI data rate. Two cascaded PLAYER a devices provide
a data rate twice the FDDI data rate; three cascaded
PLAYER a devices provide a data rate three times the FDDI
data rate, etc.
Multiple data streams are transmitted in parallel over each
pair of cascaded PLAYER a devices. All data streams start
simultaneously and begin with the JK symbol pair on each
PLAYER a device.
Data is synchronized at the receiver of each PLAYER a device by the JK symbol pair. Upon receiving a JK symbol pair,
a PLAYER a device asserts the Cascade Ready signal to
indicate the beginning of data reception.
The Cascade Ready signals of all PLAYER a devices are
open drain ANDed together to create the Cascade Start
signal. The Cascade Start signal is used as the input to
indicate that all PLAYER a devices have received the JK
symbol pair. Data is now being received at every PLAYER a
device and can be transferred from the cascaded
PLAYER a devices to the host system.
See Figure 4-6 for more information.
Operating Rules
When the PLAYER a device is operating in Cascade mode,
the following rules apply:
1. Data integrity can be guaranteed if the worst case PMD
transmission skew between parallel media is less than
40 ns. For example, this amounts to about 785 meters of
fiber optic cable, assuming a 1% worst case variance.
2. Even though this is a non-FDDI application, the general
rules for FDDI frames must be obeyed.
(including the JK symbol pair). Smaller frames will
cause Elasticity Buffer errors.
# Data frames must have a maximum size of 4500 bytes,
with a JK starting delimiter and a T or R or S ending
delimiter.
3. Due to the different clock rates, the JK symbol pair may
arrive at different times at each PLAYER a device. The
total skew between the fastest and slowest cascaded
PLAYER a devices receiving the JK starting delimiter
must not exceed 80 ns.
4. The first PLAYER a device to receive a JK symbol pair
will present it to the host system and release the Cascade Ready signal. The PLAYER a device will present
one more JK as it waits for the other PLAYER a devices
to recognize their JK. The maximum number of consecutive JKs that can be presented to the host is 2.
5. The Cascade Start signal is set to 1 when all the cascaded PLAYER a devices release their Cascade Ready signals.
6. Bit 4 (CSE) of the Receive Condition Register B (RCRB)
is set to 1 if the Cascade Start signal (CS) is not set
before the second falling edge of clock signal LBC from
when Cascade Ready (CR) was released. CS has to be
set approximately within 80 ns of CR release. This condition signifies that not all cascaded PLAYER a devices
have received their respective JK symbol pair with the
allowed skew range.
7. PLAYER a devices may not report a Cascaded Synchronization Error if the JK symbols are corrupted in the pointto-point links.
8. To guarantee integrity of the interframe information, the
user must put at least 8 Idle symbol pairs between
frames. The PLAYER a device will function properly with
only 4 Idle symbol pairs, however the interframe symbols
may be corrupted with random non-JK symbols.
The MACSI device could be used to provide the required
framing and optional FCS support.
35
4.0 Modes of Operation (Continued)
TL/F/11708 – 27
FIGURE 4-5. Parallel Transmission
TL/F/11708 – 28
FIGURE 4-6. Cascade Mode of Operation
36
5.0 Registers
The PLAYER a device can be initialized, configured, and monitored using 64 8-bit registers. These registers are accessible
through the Control Bus Interface.
The following tables summarize each register’s attributes.
Note: RESERVED Registers may be read at any time, although the values read are not specified. The results of RESERVED Register writes are not specified, and
may have adverse implications. The user should not write to RESERVED Register locations.
TABLE 5-1. Register Summary
Access Rules
Register
Address
Register
Symbol
00h
MR
Mode Register
Always
Always
01h
CR
Configuration Register
Always
Conditional
02h
ICR
Interrupt Condition Register
Always
Conditional
03h
ICMR
Interrupt Condition Mask Register
Always
Always
04h
CTSR
Current Transmit State Register
Always
Conditional
05h
IJTR
Injection Threshold Register
Always
Always
06h
ISRA
Injection Symbol Register A
Always
Always
07h
ISRB
Injection Symbol Register B
Always
Always
08h
CRSR
Current Receive State Register
Always
Write Reject
09h
RCRA
Receive Condition Register A
Always
Conditional
0Ah
RCRB
Receive Condition Register B
Always
Conditional
0Bh
RCMRA
Receive Condition Mask Register A
Always
Always
0Ch
RCMRB
Receive Condition Mask Register B
Always
Always
0Dh
NTR
Noise Threshold Register
Always
Always
0Eh
NPTR
Noise Prescale Threshold Register
Always
Always
0Fh
CNCR
Current Noise Count Register
Always
Write Reject
10h
CNPCR
Current Noise Prescale Count Register
Always
Write Reject
11h
STR
State Threshold Register
Always
Always
12h
SPTR
State Prescale Threshold Register
Always
Always
13h
CSCR
Current State Count Register
Always
Write Reject
14h
CSPCR
Current State Prescale Count Register
Always
Write Reject
15h
LETR
Link Error Threshold Register
Always
Always
16h
CLECR
Current Link Error Count Register
Always
Write Reject
17h
UDR
User Definable Register
Always
Always
18h
IDR
Device ID Register
Always
Write Reject
19h
CIJCR
Current Injection Count Register
Always
Write Reject
1Ah
ICCR
Interrupt Condition Comparison Register
Always
Always
1Bh
CTSCR
Current Transmit State Comparison Register
Always
Always
1Ch
RCCRA
Receive Condition Comparison Register A
Always
Always
Register Name
Read
37
Write
5.0 Registers (Continued)
TABLE 5-1. Register Summary (Continued)
Register
Address
Register
Symbol
Access Rules
Register Name
Read
Write
1Dh
RCCRB
Receive Condition Comparison Register B
Always
Always
1Eh
MODE2
Mode Register 2
Always
Conditional
1Fh
CMTCCR
CMT Condition Comparison Register
Always
Always
20h
CMTCR
CMT Condition Register
Always
Conditional
21h
CMTMR
CMT Condition Mask Register
Always
Always
22h
RR22
Reserved Register 22
Always
DO NOT WRITE
23h
RR23
Reserved Register 23
Always
DO NOT WRITE
24h
STTR
Scrub Timer Threshold Register
Always
Always
25h
STVR
Scrub Timer Value Register
Always
Write Reject
26h
TDR
Trigger Definition Register
Always
Always
27h
TTCR
Trigger Transition Configuration Register
Always
Always
28h
RR28
Reserved Register 28
Always
DO NOT WRITE
29h
RR29
Reserved Register 29
Always
DO NOT WRITE
2Ah
RR2A
Reserved Register 2A
Always
DO NOT WRITE
2Bh
RR2B
Reserved Register 2B
Always
DO NOT WRITE
2Ch
RR2C
Reserved Register 2C
Always
DO NOT WRITE
2Dh
RR2D
Reserved Register 2D
Always
DO NOT WRITE
2Eh
RR2E
Reserved Register 2E
Always
DO NOT WRITE
2Fh
RR2F
Reserved Register 2F
Always
DO NOT WRITE
30h
RR30
Reserved Register 30
Always
DO NOT WRITE
31h
RR31
Reserved Register 31
Always
DO NOT WRITE
32h
RR32
Reserved Register 32
Always
DO NOT WRITE
33h
RR33
Reserved Register 33
Always
DO NOT WRITE
34h
RR34
Reserved Register 34
Always
DO NOT WRITE
35h
RR35
Reserved Register 35
Always
DO NOT WRITE
36h
RR36
Reserved Register 36
Always
DO NOT WRITE
37h
RR37
Reserved Register 37
Always
DO NOT WRITE
38h
RR38
Reserved Register 38
Always
DO NOT WRITE
39h
RR39
Reserved Register 39
Always
DO NOT WRITE
3Ah
RR3A
Reserved Register 3A
Always
DO NOT WRITE
3Bh
CGMREG
Clock Generation Module Register
Always
Always
3Ch
APMDREG
Alternate PMD Register
Always
Always
3Dh
GAINREG
Gain Register
Always
Always
3Eh
RR3E
Reserved Register 3E
Always
DO NOT WRITE
3Fh
RR3F
Reserved Register 3F
Always
DO NOT WRITE
38
5.0 Registers (Continued)
TABLE 5-2. Register Bit Summary
Register
Address
Register
Symbol
00h
01h
Bit Symbols
D7
D6
D5
D4
MR
RNRZ
TNRZ
TE
TQL
CM
EXLB
ILB
RUN
CR
BIE
AIE
TRS1
TRS0
BIS1
BIS0
AIS1
AIS0
02h
ICR
UDI
RCB
RCA
LEMT
CWI
CCR
CPE
DPE
03h
ICMR
UDIM
RCBM
RCAM
LEMTM
CWIM
CCRM
CPEM
DPEM
04h
CTSR
RES
PRDPE
SE
IC1
IC0
TM2
TM1
TM0
05h
IJTR
IJT7
IJT6
IIJ5
IJT4
IJT3
IJT2
IJT1
IJT0
06h
ISRA
RES
RES
RES
IJS4
IJS3
IJS2
IJS1
IJS0
07h
ISRB
RES
RES
RES
IJS9
IJS8
IJS7
IJS6
IJS5
08h
CRSR
RES
RES
RES
RES
LSU
LS2
LS1
LS0
09h
RCRA
LSUPI
LSC
NT
NLS
MLS
HLS
QLS
NSD
0Ah
RCRB
RES
SILS
EBOU
CSE
LSUPV
ALS
ST
ILS
0Bh
RCMRA
LSUPIM
LSCM
NTM
NLSM
MLSM
HLSM
QLSM
NSDM
0Ch
RCMRB
RES
SILSM
EBOUM
CSEM
LSUPVM
ALSM
STM
ILSM
0Dh
NTR
RES
NT6
NT5
NT4
NT3
NT2
NT1
NT0
0Eh
NPTR
NPT7
NPT6
NPT5
NPT4
NPT3
NPT2
NPT1
NPT0
0Fh
CNCR
NCLSCD
CNC6
CNC5
CNC4
CNC3
CNC2
CNC1
CNC0
10h
CNPCR
CNPC7
CNPC6
CNPC5
CNPC4
CNPC3
CNPC2
CNPC1
CNPC0
11h
STR
RES
ST6
ST5
ST4
ST3
ST2
ST1
ST0
12h
SPTR
SPT7
SPT6
SPT5
SPT4
SPT3
SPT2
SPT1
SPT0
13h
CSCR
SCLSCD
CSC6
CSC5
CSC4
CSC3
CSC2
CSC1
CSC0
14h
CSPCR
CSPC7
CSPC6
CSPC5
CSPC4
CSPC3
CSPC2
CSPC1
CSPC0
15h
LETR
LET7
LET6
LET5
LET4
LET3
LET2
LET1
LET0
16h
CLECR
LEC7
LEC6
LEC5
LEC4
LEC3
LEC2
LEC1
LEC0
17h
UDR
RES
RES
RES
RES
EB1
EB0
SB1
SB0
18h
IDR
DID7
DID6
DID5
DID4
DID3
DID2
DID1
DID0
19h
CIJCR
IJC7
IJC6
IJC5
IJC4
IJC3
IJC2
IJC1
IJC0
1Ah
ICCR
UDIC
RCBC
RCAC
LEMTC
CWIC
CCRC
CPEC
DPEC
1Bh
CTSCR
RESC
PRDPEC
SEC
IC1C
IC0C
TM2C
TM1C
TM0C
1Ch
RCCRA
LSUPIC
LSCC
NTC
NLSC
MLSC
HLSC
QLSC
NSDC
1Dh
RCCRB
RESC
SILSC
EBOUC
CSEC
LSUPVC
ALSC
STC
ILSC
1Eh
MODE2
ESTC
RES
CLKSEL
RES
RES
RES
CBPE
PHYRST
1Fh
CMTCCR
TCOC
STEC
RES
RES
RES
RES
RES
RES
20h
CMTCR
TCO
STE
RES
RES
RES
RES
RES
RES
21h
CMTMR
TCOM
STEM
RES
RES
RES
RES
RES
RES
22h
RR22
RES
RES
RES
RES
RES
RES
RES
RES
39
D3
D2
D1
D0
5.0 Registers (Continued)
TABLE 5-2. Register Bit Summary (Continued)
Register
Address
Register
Symbol
Bit Symbols
D7
D6
D5
D4
D3
D2
D1
D0
RES
23h
RR23
RES
RES
RES
RES
RES
RES
RES
24h
STTR
STT7
STT6
STT5
STT4
STT3
STT2
STT1
STT0
25h
STVR
STV7
STV6
STV5
STV4
STV3
STV2
STV1
STV0
26h
TDR
TONT
TOQLS
TOHLS
TOMLS
TOSILS
TTM2
TTM1
TTM0
27h
TTCR
BIE
AIE
TRS1
TRS0
BIS1
BIS0
AIS1
AIS0
28h
RR28
RES
RES
RES
RES
RES
RES
RES
RES
29h
RR29
RES
RES
RES
RES
RES
RES
RES
RES
2Ah
RR2A
RES
RES
RES
RES
RES
RES
RES
RES
2Bh
RR2B
RES
RES
RES
RES
RES
RES
RES
RES
2Ch
RR2C
RES
RES
RES
RES
RES
RES
RES
RES
2Dh
RR2D
RES
RES
RES
RES
RES
RES
RES
RES
2Eh
RR2E
RES
RES
RES
RES
RES
RES
RES
RES
2Fh
RR2F
RES
RES
RES
RES
RES
RES
RES
RES
30h
RR30
RES
RES
RES
RES
RES
RES
RES
RES
31h
RR31
RES
RES
RES
RES
RES
RES
RES
RES
32h
RR32
RES
RES
RES
RES
RES
RES
RES
RES
33h
RR33
RES
RES
RES
RES
RES
RES
RES
RES
34h
RR34
RES
RES
RES
RES
RES
RES
RES
RES
35h
RR35
RES
RES
RES
RES
RES
RES
RES
RES
36h
RR36
RES
RES
RES
RES
RES
RES
RES
RES
37h
RR37
RES
RES
RES
RES
RES
RES
RES
RES
38h
RR38
RES
RES
RES
RES
RES
RES
RES
RES
39h
RR39
RES
RES
RES
RES
RES
RES
RES
RES
3Ah
RR3A
RES
RES
RES
RES
RES
RES
RES
RES
3Bh
CGMREG
RES
RES
FLTREN
RES
TXCE
RES
RES
RES
RES
3Ch
APMDREG
RES
RES
RES
RES
APMDEN
RES
RES
3Dh
GAINREG
FILT2
FILT1
FILT0
RES
RES
RES
RES
RES
3Eh
RR3E
RES
RES
RES
RES
RES
RES
RES
RES
3Fh
RR3F
RES
RES
RES
RES
RES
RES
RES
RES
40
5.0 Registers (Continued)
TABLE 5-3. Register Reset Value Summary
Reset Contents
Register
Address
Register
Symbol
00h
MR
00 h
01h
CR
00 h
02h
ICR
X001 0000 B
03h
ICMR
00 h
04h
CTSR
A2 h
05h
IJTR
00 h
06h
ISRA
00 h
07h
ISRB
00 h
08h
CRSR
0A h
09h
RCRA
20 h
0Ah
RCRB
00X0 0010 B
0Bh
RCMRA
00 h
0Ch
RCMRB
00 h
0Dh
NTR
00 h
0Eh
NPTR
00 h
0Fh
CNCR
00 h
10h
CNPCR
00 h
11h
STR
00 h
12h
SPTR
00 h
13h
CSCR
00 h
14h
CSPCR
00 h
15h
LETR
00 h
16h
CLECR
00 h
17h
UDR
000X 00XX B
depends on sense pins
18h
IDR
XX h
depends on chip version
MSB-LSB
Comments
depends on sense pins
depends on EB state
19h
CIJCR
00 h
1Ah
ICCR
00 h
same as reg 02 h if reg 02 h is read first
1Bh
CTSCR
00 h
same as reg 04 h if reg 04 h is read first
1Ch
RCCRA
00 h
same as reg 09 h if reg 09 h is read first
1Dh
RCCRB
00 h
same as reg 0A h if reg 0A h is read first
41
5.0 Registers (Continued)
TABLE 5-3. Register Reset Value Summary (Continued)
Register
Address
Reset Contents
Register
Symbol
MSB-LSB
1Eh
MODE2
00 h
1Fh
CMTCCR
00 h
20h
CMTCR
00 h
21h
CMTMR
00 h
22h
RR22
XX h
23h
RR23
XX h
24h
STTR
00 h
25h
STVR
00 h
26h
TDR
00 h
27h
TTCR
00 h
28h
RR28
XX h
29h
RR29
XX h
2Ah
RR2A
XX h
2Bh
RR2B
XX h
2Ch
RR2C
XX h
2Dh
RR2D
XX h
2Eh
RR2E
XX h
2Fh
RR2F
XX h
30h
RR30
XX h
31h
RR31
XX h
32h
RR32
XX h
33h
RR33
XX h
34h
RR34
XX h
35h
RR35
XX h
36h
RR36
XX h
37h
RR37
XX h
38h
RR38
XX h
39h
RR39
XX h
3Ah
RR3A
XX h
3Bh
CGMREG
05 h
3Ch
APMDREG
00 h
3Dh
GAINREG
00 h
3Eh
RR3E
XX h
3Fh
RR3F
XX h
42
Comments
5.0 Registers (Continued)
5.1 MODE REGISTER (MR)
The Mode Register is used to initialize and configure the PLAYER a device.
ACCESS RULES
ADDRESS
READ
WRITE
00h
Always
Always
D7
D6
D5
D4
D3
D2
D1
D0
RNRZ
TNRZ
TE
TQL
CM
LILB
SILB
RUN
Bit
Symbol
D0
RUN
Description
RUN/ E STOP:
0: Enables the STOP mode. Refer to section 4.2, STOP MODE, for more information.
1: Normal operation (i.e. RUN mode).
Note: The RUN bit is automatically set to 0 when the E RST pin is asserted (i.e. set to ground).
D1
SILB
SHORT INTERNAL LOOPBACK:
0: Disables Internal Loopback mode (i.e. normal operation).
1: Enables Internal Loopback mode.
Refer to section 4.3, LOOPBACK MODE, for more information.
D2
LILB
LONG INTERNAL LOOPBACK:
0: Disables Long Internal Loopback mode (i.e. normal operation).
1: Enables Long Internal Loopback mode.
Note: Long Internal Loopback should not be used when the Alternate PMD Interface is enabled.
Refer to section 4.3, LOOPBACK MODE, for more information.
D3
CM
CASCADE MODE:
0: Disables synchronization of cascaded PLAYER a devices.
1: Enables the synchronization of cascaded PLAYER a devices.
Refer to section 4.4, CASCADE MODE, for more information.
Note: Cascade Mode is only available on the DP83257 device. The other devices do not have the required CS and CR pins. Do not set this bit for
any device but the DP83257.
D4
TQL
TRANSMIT QUIET LEVEL: This bit is used to program the transmission level of the Quiet symbols during Off
Transmit mode (OTM) only.
0: Low (PMD OFF) level Quiet symbols are transmitted through the PMD Data Request pins (i.e. PMRD a e low,
PMRD b e high).
1: High (PMD ON) level Quiet symbols are transmitted through the PMD Data Request pins (i.e. PMRD a e high,
PMRD b e low).
D5
TE
TRANSMIT ENABLE: The TE bit controls the action of the PMD transmitter Enable (TXE) pin. When TE is 0, the
TXE output disables the PMD transmitter; when TE is 1, the PMD transmitter is disabled during the Off Transmit
Mode (OTM) and enabled otherwise. The On and Off level of the TXE is depended on the PMD transmitter Enable
Level (TEL) pin to the PLAYER a device. The following rules summaries the output of TXE.
1. If TE e 0, then TXE e Off
2. If TE e 1 and OTM, then TXE e Off
3. If TE e 1 and not OTM, then TXE e On.
D6
TNRZ
TRANSMIT NRZ DATA:
0: Transmits data in Non-Return-To-Zero-Invert-On-Ones (NRZI) format (normal format).
1: Transmits data in Non-Return-To-Zero format (NRZ).
D7
RNRZ
RECEIVE NRZ DATA:
0: Receives data in Non-Return-To-Zero-Invert-On-Ones format (NRZI) (normal format).
1: Receives data in Non-Return-To-Zero format (NRZ).
43
5.0 Registers (Continued)
5.2 CONFIGURATION REGISTER (CR)
The Configuration Register controls the Configuration Switch Block and enables/disables both the A and B ports. The CR can
be used to create a number of Configuration Loopback paths.
The CR is conditionally writable because the TTCR can be writing a new value into the register if this feature is enabled.
Note that the AÐRequest and BÐIndicate port are offered only on the DP83257, and not in the DP83256. For further information, refer to section 3.4, CONFIGURATION SWITCH.
ACCESS RULES
ADDRESS
READ
WRITE
01h
Always
Conditional
D7
D6
D5
D4
D3
D2
D1
D0
BIE
AIE
TRS1
TRS0
BIS1
BIS0
AIS1
AIS0
Bit
D0, D1
Symbol
AIS0, AIS1
Description
AÐINDICATE SELECTOR k0, 1l: The AÐIndicate Selector k0, 1l bits selects one of the four
Configuration Switch data buses for the A Indicate output port (AIP, AIC, AIDk7:0l).
Ð
AIS1
0
0
1
1
D2, D3
BIS0, BIS1
AIS0
0
1
0
1
PHY Invalid Bus
Receiver Bus
AÐRequest Bus
BÐRequest Bus
BÐINDICATE SELECTOR k0, 1l: The BÐIndicate Selector k0, 1l bits selects one of the four
Configuration Switch data buses for the BÐIndicate output port (BIP, BIC, BIDk7:0l)
BIS1
0
0
1
1
BIS0
0
1
0
1
PHY Invalid Bus
Receiver Bus
AÐRequest Bus
BÐRequest Bus
Note: Even though this bit can be set and/or cleared in the DP83256, it will not affect any I/Os since the DP83256 does not offer a
BÐIndicate port.
D4, D5
TRS0, TRS1
TRANSMIT REQUEST SELECTOR k0, 1l: The Transmit Request Selector k0, 1l bits select one of
the four Configuration Switch data buses for the input to the Transmitter Block.
TRS1
0
0
1
1
TRS0
0
1
0
1
PHY Invalid Bus
Receiver Bus
AÐRequest Bus
BÐRequest Bus
Note: If the PLAYER a device is in Active Transmit Mode (i.e. the Transmit Mode bits (TM k 2:0 l ) of the Current Transmit State
Register (CTSR) are set to 00) and the PHY Invalid Bus is selected, then the PLAYER a device will transmit a maximum of four
Halt symbol pairs and then continuous Idle symbols due to the Repeat Filter when in the Repeat state.
D6
AIE
AÐINDICATE ENABLE:
0: Disables the AÐIndicate output port. The AÐIndicate port pins will be tri-stated when the port is
disabled.
1: Enables the AÐIndicate output port (AIP, AIC, AIDk7:0l).
D7
BIE
BÐINDICATE ENABLE:
0: Disables the BÐIndicate output port. The BÐIndicate port pins will be tri-stated when the port is
disabled.
1: Enables the BÐIndicate output port (BIP, BIC, BIDk7:0l).
Note: Even though this bit can be set and/or cleared in the DP83256, it will not affect any I/Os since the DP83256 does not offer a
BÐIndicate port.
44
5.0 Registers (Continued)
5.3 INTERRUPT CONDITION REGISTER (ICR)
The Interrupt Condition Register records the occurrence of an internal error event, the detection of Line State, an unsuccessful
write by the Control Bus Interface, the expiration of an internal counter, or the assertion of one or more of the User Definable
Sense pins.
The Interrupt Condition Register will assert the Interrupt pin ( E INT) when one or more bits within the register are set to 1 and
the corresponding mask bits in the Interrupt Condition Mask Register (ICMR) are also set to 1.
ACCESS RULES
ADDRESS
READ
WRITE
02h
Always
Conditional
D7
D6
D5
D4
D3
D2
D1
D0
UDI
RCB
RCA
LEMT
CWI
CCR
CPE
DPE
Bit
Symbol
D0
DPE
Description
PHYÐREQUESTÐDATA PARITY ERROR: This bit will be set to 1 when:
1. The PHY Request Data Parity Enable bit (PRDPE) of the Current Transmit State Register (CTSR) is set to 1 and
2. The Transmitter Block detects a parity error in the incoming PHY Request Data.
The source of the data can be from the PHY Invalid Bus, the Receive Bus, the AÐBus, or the BÐBus of the
Configuration Switch.
Note: Parity is only checked on data that goes into the transmitter block. This means that any data that is just routed through the configuration
switch without going into the transmit block is not checked.
D1
CPE
Control Bus DATA PARITY ERROR: This bit will be set to 1 when the Control Bus Interface detects a parity error
in the incoming Control Bus Data (CBDk7:0l), CBP during a write cycle.
D2
CCR
Control Bus WRITE COMMAND REJECT: This bit will be set to 1 when an attempt to write into one of the
following read-only registers is made:
Current Receive State Register (Register 08, CRSR)
Current Noise Count Register (Register 0F, CNCR)
Current Noise Prescale Count Register (Register 10, CNPCR)
Current State Count Register (Register 13, CSCR)
Current State Prescale Count Register (Register 14, CSPCR)
Current Link Error Count Register (Register 16, CLECR)
Device ID Register (Register 18, IDR)
Current Injection Count Register (Register 19, CIJCR)
Scrub Timer Value Register (Register 25, STVR)
45
5.0 Registers (Continued)
Bit
Symbol
D3
CWI
Description
CONDITIONAL WRITE INHIBIT: Set to 1 when bits within mentioned registers do not match bits in the
corresponding compare register. This bit ensures that new (i.e. unread) data is not inadvertently cleared while old
data is being cleared through the Control Bus Interface.
This bit is set to 1 to indicate that a bit in a condition write register was not written because it had changed since
the previous read. The following registers are affected:
Interrupt Condition Register (Register 02, ICR)
Current Transmit State Register (Register 04, CTSR)
Receive Condition Register A (Register 09, RCRA)
Receive Condition Register B (Register 0A, RCRB)
CMT Condition Register (Register 20, CMTCR)
The previous registers are affected when they differ from the value of the corresponding bit in the following
registers respectively:
Interrupt Condition Compare Register (Register 1A, ICCR)
Current Transmit State Compare Register (Register 1B, CTSCR)
Receive Condition Compare Register A (Register 1C, RCCRA)
Receive Condition Compare Register B (Register 1D, RCCRB)
CMT Condition Compare Register (Register 1F, CMTCCR)
This bit must be cleared by software. Note that this differs from the MACSI, BMAC and BSI device bits of the same
name.
The Configuration Register (Register 01, CR) can not be written to during scrubbing.
D4
LEMT
LINK ERROR MONITOR THRESHOLD: This bit is set to 1 when the internal 8-bit Link Error Monitor Counter
reaches zero. It will remain set and is cleared by software.
During the reset process (i.e. E RST e GND), the Link Error Monitor Threshold bit is set to 1 because the Link
Error Monitor Counter is initialized to zero.
D5
RCA
RECEIVE CONDITION A: This bit is set to 1 when:
1. One or more bits in the Receive Condition Register A (RCRA) is set to 1 and
2. The corresponding mask bits in the Receive Condition Mask Register A (RCMRA) are also set to 1.
In order to clear (i.e. set to 0) the Receive Condition A bit, the bits within the Receive Condition Register A that are
set to 1 must first be either cleared or masked.
D6
RCB
RECEIVE CONDITION B: This bit is set to 1 when:
1. One or more bits in the Receive Condition Register B (RCRB) is set to 1 and
2. The corresponding mask bits in the Receive Condition Mask Register A (RCMRB) are also set to 1.
In order to clear (i.e. set to 0) the Receive Condition B bit, the bits within the Receive Condition Register B that are
set to 1 must first be either cleared or masked.
D7
UDI
USER DEFINABLE INTERRUPT: This bit is set to 1 when one or any combination of the Sense Bits (SB0, SB1, or
SB2) in the User Definable Register (UDR) are set to 1.
In order to clear (i.e. set to 0) the User Definable Interrupt Bit, all Sense Bits must be set to 0.
46
5.0 Registers (Continued)
5.4 INTERRUPT CONDITION MASK REGISTER (ICMR)
The Interrupt Condition Mask Register allows the user to dynamically select which events will generate an interrupt.
The Interrupt pin will be asserted (i.e. E INT e GND) when one or more bits within the Interrupt Condition Register (ICR) are set
to 1 and the corresponding mask bits in this register are also set to 1.
This register is cleared (i.e. set to 0) and all interrupts are initially masked during the reset process.
ACCESS RULES
ADDRESS
READ
WRITE
03h
Always
Always
D7
D6
D5
D4
D3
D2
D1
D0
UDIM
RCBM
RCAM
LEMTM
CWIM
CCRM
CPEM
DPEM
Bit
Symbol
Description
D0
DPEM
PHYÐREQUESTÐDATA PARITY ERROR MASK: The mask bit for the PHYÐRequest Data Parity Error bit
(DPE) of the Interrupt Condition Register (ICR).
D1
CPEM
Control Bus DATA PARITY ERROR MASK: The mask bit for the Control Bus Data Parity Error bit (CPE) of the
Interrupt Condition Register (ICR).
D2
CCRM
Control Bus WRITE COMMAND REJECT MASK: The mask bit for the Control Bus Write Command Reject bit
(CCR) of the Interrupt Condition Register (ICR).
D3
CWIM
CONDITIONAL WRITE INHIBIT MASK: The mask bit for the Conditional Write Inhibit bit (CWI) of the Interrupt
Condition Register (ICR).
D4
LEMTM
LINK ERROR MONITOR THRESHOLD MASK: The mask bit for the Link Error Monitor Threshold bit (LEMT) of
the Interrupt Condition Register (ICR).
D5
RCAM
RECEIVE CONDITION A MASK: The mask bit for the Receive Condition A bit (RCA) of the Interrupt Condition
Register (ICR).
D6
RCBM
RECEIVE CONDITION B MASK: The mask bit for the Receive Condition B bit (RCB) of the Interrupt Condition
Register (ICR).
D7
UDIM
USER DEFINABLE INTERRUPT MASK: The mask bit for the User Definable Interrupt bit (UDI) of the Interrupt
Condition Register (ICR).
47
5.0 Registers (Continued)
5.5 CURRENT TRANSMIT STATE REGISTER (CTSR)
The Current Transmit State Register can program the Transmitter Block to internally generate and transmit Idle, Master, Halt,
Quiet, or user programmable symbol pairs, in addition to the normal transmission of incoming PHY Request data. The Smoother
and PHY Request Data Parity are also enabled and disabled through this register.
When the Trigger Definition register (TDR) is used, the CTSR can automatically be set to a preprogrammed line state when a
trigger condition occurs. This capability can be used to implement both PCÐReact and CFÐReact.
The Transmit Modes have priority over the Repeat Filter and Smoother outputs. The Injection Symbols have priority over the
Transmit Modes.
During the reset process (i.e. E RST e GND) the Transmit Mode is set to Off (TMk2:0l e 010), the Smoother is enabled (i.e. SE
is set to 1), and the Reserved bit (b7) is set to 1. All other bits of this register are cleared (i.e. set to 0) during the reset process.
When the TDR register is used to respond to trigger conditions the CTSR will be blocked when the TDR register transmit mode
is copied into the CTSR. The Write Reject bit of the ICR will be set if any writes are attempted at this time.
Note: This register has no effect while the device is in Stop Mode.
ACCESS RULES
ADDRESS
READ
WRITE
04h
Always
Conditional
D7
D6
D5
D4
D3
D2
D1
D0
RES
PRDPE
SE
IC1
IC0
TM2
TM1
TM0
Bit
D0, D1,
D2
Symbol
TM0, TM1,
TM2
Description
Transmit Mode k0, 1, 2l: These bits select one of the 6 transmission modes for the PMD Request Data
output port (TXD g ).
TM2
0
0
0
TM1
0
0
1
TM0
0
1
0
0
1
1
1
0
0
1
1
1
0
1
1
1
0
1
Active Transmit Mode (ATM): Normal transmission of incoming PHY Request data.
Idle Transmit Mode (ITM): Transmission of Idle symbol pairs (11111 11111).
Off Transmit Mode (OTM): Transmission of Quiet symbol pairs (00000 00000) and
deassertion of the PMD transmitter Enable pin (TXE).
Note: This is the default transmit mode after reset.
Reserved: Reserved for future use. Users are discouraged from using this transmit
mode. If selected, however, the transmitter will generate Quiet symbol pairs (00000
00000).
Master Transmit Mode (MTM): Transmission of Halt and Quiet symbol pairs (00100
00000).
Halt Transmit Mode (HTM): Transmission of Halt symbol pairs (00100 00100).
Quiet Transmit Mode (QTM): Transmission of Quiet symbol pairs (00000 00000).
Reserved: Reserved for future use. Users are discouraged from using this transmit
mode. If selected, however, the transmitter will generate Quiet symbol pairs
(00000 00000).
48
5.0 Registers (Continued)
Bit
Symbol
D3, D4
IC0, IC1
Description
Injection Control k0, 1l: These bits select one of the 4 injection modes. The injection modes have priority
over data from the Smoother, Repeat Filter, Encoder, and Transmit Modes.
IC0 is the only bit of the register that is automatically cleared by the PLAYER a device after the One Shot
Injection is executed. The automatic clear of IC0 during the One Shot mode can be interpreted as a
acknowledgment that the One Shot has been completed.
IC1
0
IC0
0
0
1
One Shot: In one shot mode, the contents of Injection Symbol Register A (ISRA) and Injection
Symbol Register B (ISRB) are injected n symbol pairs after a JK, where n is the programmed
value of the Injection Count Register (IJCR). If IJCR is set to 0, the JK symbol pair is replaced by
ISRA and ISRB. Once the One Shot is executed, the PLAYER a device automatically sets IC0 to
0, thereby returning to normal transmission of data.
1
0
Periodic: In Periodic mode, the contents of Injection Symbol Register A (ISRA) and Injection
Symbol Register B (ISRB) are injected every n-th symbol pair, where n is the programmed value
of the Injection Count Register (IJCR). If IJCR is set to 0, all data symbols are replaced with ISRA
and ISRB.
No Injection: The normal transmission of incoming PHY Request data (i.e. symbols are not
injected).
Note: The inserted symbol is not automatically aligned to a JK boundary.
1
D5
SE
1
Continuous: In Continuous mode, all data symbols are replaced with the contents of Injection
Symbol Register A (ISRA) and Injection Symbol Register B (ISRB).
SMOOTHER ENABLE:
0:
1:
Disables the Smoother.
Enables the Smoother.
When enabled, the Smoother can redistribute Idle symbol pairs which were added or deleted by the
local or upstream receivers.
Note: Once the counter has started, it will continue to count irrespective of the incoming symbols with the exception of a JK symbol pair.
D6
PRDPE
PHYÐREQUEST DATA PARITY ENABLE:
0:
1:
D7
RES
Disables PHYÐRequest Data parity.
Enables PHYÐRequest Data parity.
RESERVED: Reserved for future use.
Note: Users are discouraged from using this bit. The reserved bit is set to 1 during the reset process. It may be set or cleared without any
effects to the functionality of the PLAYER a device.
49
5.0 Registers (Continued)
5.6 INJECTION THRESHOLD REGISTER (IJTR)
The Injection Threshold Register, in conjunction with the Injection Control bits (IC k1:0l) in the Current Transmit State Register
(CTSR), set the frequency at which the contents of the Injection Symbol Register A (ISRA) and Injection Symbol Register B
(ISRB) are inserted into the data stream. It contains the start value for the Injection Counter.
The Injection Threshold Register value is loaded into the Injection Counter when the counter reaches zero or during every
Control Bus Interface write-cycle of this register.
The Injection Counter is an 8-bit down-counter which decrements every 80 ns. It’s current value is read for CIJCR.
The counter is active only during One Shot or Periodic Injection Modes (i.e. Injection Controlk1:0l bits (ICk1:0l) of the
Current Transmit State Register (CTSR) are set to either 01 or 10). The Transmitter Block will replace a data symbol pair with
ISRA and ISRB when the counter reaches 0 and the Injection Mode is either One Shot or Periodic.
If the Injection Threshold Register is set to 0 during the One Shot mode, the JK will be replaced with ISRA and ISRB. If the
Injection Threshold Register is set to 0 during the Periodic mode, all data symbols are replaced with ISRA and ISRB.
The counter is initialized to 0 during the reset process (i.e. E RST e GND).
For further information, see the INJECTION CONTROL LOGIC section.
ACCESS RULES
ADDRESS
READ
WRITE
05h
Always
Always
D7
D6
D5
D4
D3
D2
D1
D0
IJT7
IJT6
IJT5
IJT4
IJT3
IJT2
IJT1
IJT0
Bit
D0-D7
Symbol
IJT0 – IJT7
Description
INJECTION THRESHOLD BITk0-7l: Start value for the Injection Counter.
IJT0 is the Least Significant Bit (LSB).
50
5.0 Registers (Continued)
5.7 INJECTION SYMBOL REGISTER A (ISRA)
The Injection Symbol Register A, along with Injection Symbol Register B, contains the programmable value (already in 5B code)
that can be inserted to replace the data symbol pairs.
In One Shot mode, ISRA and ISRB are injected n bytes after a JK, where n is the programmed value of the Injection Threshold
Register. In the Periodic mode, ISRA and ISRB are injected every n-th symbol pair. In the Continuous mode, all data symbols are
replaced with ISRA and ISRB.
ACCESS RULES
ADDRESS
READ
WRITE
06h
Always
Always
D7
D6
D5
D4
D3
D2
D1
D0
RES
RES
RES
IJS4
IJS3
IJS2
IJS1
IJS0
Bit
Symbol
D0 – D4
IJS0–IJS4
INJECTION SYMBOL BITk0-4l: Symbol to be injected.
Description
D5 – D7
RES
RESERVED: Reserved for future use.
IJS0 is the Least Significant Bit (LSB) and goes out onto the media last.
Note: Users are discouraged from using these bits. The reserved bits are set to 0 during the reset process. They may be set or cleared
without any effects to the functionality of the PLAYER a device.
51
5.0 Registers (Continued)
5.8 INJECTION SYMBOL REGISTER B (ISRB)
The Injection Symbol Register B, along with Injection Symbol Register A, contains the programmable value (already in 5B code)
that will replace the data symbol pairs.
In One Shot mode, ISRA and ISRB are injected n bytes after a JK, where n is the programmed value of the Injection Threshold
Register. In the Periodic mode, ISRA and ISRB are injected every n-th symbol pair. In the Continuous mode, all data symbols are
replaced with ISRA and ISRB.
ACCESS RULES
ADDRESS
READ
WRITE
07h
Always
Always
D7
D6
D5
D4
D3
D2
D1
D0
RES
RES
RES
IJS9
IJS8
IJS7
IJS6
IJS5
Bit
Symbol
D0 – D4
IJS0 – IJS4
INJECTION SYMBOL BITk0-4l: Symbol to be injected.
Description
D5 – D7
RES
RESERVED: Reserved for future use.
IJS0 is the Least Significant Bit (LSB) and goes out onto the media last.
Note: Users are discouraged from using these bits. The reserved bits are set to 0 during the reset process. They may be set or cleared
without any effects to the functionality of the PLAYER a device.
52
5.0 Registers (Continued)
5.9 CURRENT RECEIVE STATE REGISTER (CRSR)
The Current Receive State Register represents the current line state being detected by the Receiver Block. When the Receiver
Block recognizes a new Line State, the bits corresponding to the previous line state are cleared, and the bits corresponding to
the new line state are set.
During the reset process ( E RST e GND), the Receiver Block is forced to Line State Unknown (i.e. the Line State Unknown bit
(LSU) is set to 1).
Note: Users are discouraged from writing to this register. An attempt to write into this register will cause the PLAYER a device to ignore the Control Bus write cycle
and set the Control Bus Write Command Reject bit (CCR) of the Interrupt Condition Register (ICR) to 1.
ACCESS RULES
ADDRESS
READ
WRITE
08h
Always
Write Reject
D7
D6
D5
D4
D3
D2
D1
D0
RES
RES
RES
RES
LSU
LS2
LS1
LS0
Bit
Symbol
D0,
D1, D2
LS0, LS1,
LS2
Description
LINE STATEk0, 1, 2l: These bits represent the current Line State being detected by the Receiver Block.
Once the Receiver Block recognizes a new line state, the bits corresponding to the previous line state are
cleared, and the bits corresponding to the new line state are set.
LS2
0
LS1
0
LS0
0
0
0
1
Idle Line State (ILS): Received a minimum of two consecutive Idle symbol pairs
(11111 11111).
0
1
0
No Signal Detect (NSD): The Signal Detect (SD) has been deasserted, indicating that
the PLAYER a device is not receiving data from the PMD receiver or that clock detect is
not being received from the Clock Recovery Module. SD is ignored during internal
loopback.
Active Line State (ALS): Received a JK symbol pair (11000 10001), possibly followed
by data symbols.
Note: NSD is the default value when the device is in Stop mode. However, while in Stop mode certain data
patterns entering the Receiver Block may cause the PLAYER a to set LS0. Therefore, the user may see
either the NSD (010) or Reserved Value (011) during Stop mode.
0
1
1
Reserved: Reserved for future use.
1
0
0
Master Line State (MLS): Received a minimum of 8 consecutive Halt-Quiet symbol
pairs (00100 00000).
1
0
1
Halt Line State (HLS): Received a minimum of 8 consecutive Halt symbol pairs
(00100 00100).
1
1
0
Quiet Line State (QLS): Received a minimum of 8 consecutive Quiet symbol pairs
(00000 00000).
1
1
1
Noise Line State (NLS): Detected a minimum of 16 noise events. Refer to the Receiver
Block description for further information on noise events.
D3
LSU
LINE STATE UNKNOWN: The Receiver Block has not detected the minimum conditions to enter a known
line state. When the Line State Unknown bit is set, LSk2:0l represent the most recently known line state.
D4-D7
RES
RESERVED: Reserved for future use.
Note: Users are discouraged from using these bits. The reserved bits are reset to 0 during the reset process. They may be set or cleared
without any effects to the functionality of the PLAYER a device.
53
5.0 Registers (Continued)
5.10 RECEIVE CONDITION REGISTER A (RCRA)
The Receive Condition Register A maintains a historical record of the Line States recognized by the Receiver Block.
When a new Line State is entered, the bit corresponding to that line state is set to 1. The bits corresponding to the previous Line
States are not cleared by the PLAYER a device, thereby maintaining a record of the Line States detected.
The Receive Condition A bit (RCA) of the Interrupt Condition Register (ICR) will be set to 1 when one or more bits within the
Receive Condition Register A is set to 1 and the corresponding mask bit(s) in Receive Condition Mask Register A (RCMRA) is
also set to 1.
ACCESS RULES
ADDRESS
READ
WRITE
09h
Always
Conditional
D7
D6
D5
D4
D3
D2
D1
D0
LSUPI
LSC
NT
NLS
MLS
HLS
QLS
NSD
Bit
Symbol
D0
NSD
NO SIGNAL DETECT: Indicates that the Signal Detect pin (TTLSD) has been deasserted and that the Clock
Recovery Module is not receiving data from the PMD receiver.
Description
D1
QLS
QUIET LINE STATE: Received a minimum of eight consecutive Quiet symbol pairs (00000 00000).
D2
HLS
HALT LINE STATE: Received a minimum of eight consecutive Halt symbol pairs (00100 00100).
D3
MLS
MASTER LINE STATE: Received a minimum of eight consecutive Halt-Quiet symbol pairs (00100 00000).
D4
NLS
NOISE LINE STATE: Detected a minimum of sixteen noise events.
D5
NT
NOISE THRESHOLD: This bit is set to 1 when the internal Noise Counter reaches 0. It will remain set until a value
equal to or greater than one is loaded into the Noise Threshold Register or Noise Prescale Threshold Register.
During the reset process (i.e. E RST e GND), since the Noise Counter is initialized to 0, the Noise Threshold bit will
be set to 1.
D6
LSC
LINE STATE CHANGE: A line state change has been detected.
D7
LSUPI
LINE STATE UNKNOWN AND PHY INVALID: The Receiver Block has not detected the minimum conditions to
enter a known line state.
In addition, the most recently known line state was one of the following line states: No Signal Detect, Quiet Line
State, Halt Line State, Master Line State, or Noise Line State.
54
5.0 Registers (Continued)
5.11 RECEIVE CONDITION REGISTER B (RCRB)
The Receive Condition Register B maintains a historical record of the Lines States recognized by the Receiver Block.
When a new Line State is entered, the bit corresponding to that line state is set to 1. The bits corresponding to the previous Line
States are not cleared, thereby maintaining a record of the Line States detected.
The Receive Condition B bit (RCB) of the Interrupt Condition Register (ICR) will be set to 1 when one or more bits within the
Receive Condition Register B is set to 1 and the corresponding mask bit(s) in Receive Condition Mask Register B (RCMRB) is
also set to 1.
ACCESS RULES
ADDRESS
READ
WRITE
0Ah
Always
Conditional
D7
D6
D5
D4
D3
D2
D1
D0
RES
SILS
EBOU
CSE
LSUPV
ALS
ST
ILS
Bit
Symbol
D0
ILS
IDLE LINE STATE: Received a minimum of two consecutive Idle symbol pairs (11111 11111).
Description
D1
ST
STATE THRESHOLD: This bit will be set to 1 when the internal State Counter reaches zero. It will remain set until
a value equal to or greater than one is loaded into the State Threshold Register or State Prescale Threshold
Register, and this register is cleared.
During the reset process (i.e. E RST e GND), since the State Counter is initialized to 0, the State Threshold bit is
set to 1.
D2
ALS
ACTIVE LINE STATE: Received a JK symbol pair (11000 10001), and possibly data symbols following.
D3
LSUPV
LINE STATE UNKNOWN AND PHY VALID: The Receiver Block has not detected the minimum conditions to
enter a known line state.
D4
CSE
In addition, the most recently known line state was either Active Line State or Idle Line State.
CONNECTION SERVICE EVENT/CASCADE SYNCHRONIZATION ERROR:
When one or more bits in the CMT Condition Register (CMTCR) are set and the corresponding bit(s) in the CMT
Condition Mask Register (CMTCMR) are set, the Connection service event bit will be set to a 1.
When a synchronization error occurs, the Cascade Synchronization Error bit is set to 1. A synchronization error
occurs if the Cascade Start signal (CS) is not asserted within approximately 80 ns of Cascade Ready (CR) release.
Note: Cascade mode and the CMT features can not be used at the same time.
Note: Cascade mode is only supported on the DP83257 device.
D5
EBOU
ELASTICITY BUFFER UNDERFLOW / OVERFLOW: The Elasticity Buffer has either overflowed or underflowed.
The Elasticity Buffer will automatically recover if the condition which caused the error is only transient, but the
event bit will remain set until cleared by software.
D6
SILS
SUPER IDLE LINE STATE: Received a minimum of eight Idle symbol pairs (11111 11111).
D7
RES
RESERVED: Reserved for future use.
Note: Users are discouraged from using these bits. The reserved bits are reset to 0 during the reset process. They may be set or cleared without
any effects to the functionality of the PLAYER a device
55
5.0 Registers (Continued)
5.12 RECEIVE CONDITION MASK REGISTER A (RCMRA)
The Receive Condition Mask Register A allows the user to dynamically select which events will generate an interrupt.
The Receive Condition A bit (RCA) of the Interrupt Condition Register (ICR) will be set to 1 when one or more bits within the
Receive Condition Register A (RCRA) is set to 1 and the corresponding mask bit(s) in this register is also set to 1.
Since this register is cleared (i.e. set to 0) during the reset process, all interrupts are initially masked.
ACCESS RULES
ADDRESS
READ
WRITE
0Bh
Always
Always
D7
D6
D5
D4
D3
D2
D1
D0
LSUPIM
LSCM
NTM
NLSM
MLSM
HLSM
QLSM
NSDM
Bit
Symbol
Description
D0
NSDM
NO SIGNAL DETECT MASK: The mask bit for the No Signal Detect bit (NSD) of the Receive Condition Register A
(RCRA).
D1
QLSM
QUIET LINE STATE MASK: The mask bit for the Quiet Line State bit (QLS) of the Receive Condition Register A
(RCRA).
D2
HLSM
HALT LINE STATE MASK: The mask bit for the Halt Line State bit (HLS) of the Receive Condition Register A
(RCRA).
D3
MLSM
MASTER LINE STATE MASK: The mask bit for the Master Line State bit (MLS) of the Receive Condition Register
A (RCRA).
D4
NLSM
NOISE LINE STATE MASK: The mask bit for the Noise Line State bit (NLS) of the Receive Condition Register A
(RCRA).
D5
NTM
NOISE THRESHOLD MASK: The mask bit for the Noise Threshold bit (NT) of the Receive Condition Register A
(RCRA).
D6
LSCM
LINE STATE CHANGE MASK: The mask bit for the Line State Change bit (LSC) of the Receive Condition
Register A (RCRA).
D7
LSUPIM
LINE STATE UNKNOWN AND PHY INVALID MASK: The mask bit for the Line State Unknown and PHY Invalid
bit (LSUPI) of the Receive Condition Register A (RCRA).
56
5.0 Registers (Continued)
5.13 RECEIVE CONDITION MASK REGISTER B (RCMRB)
The Receive Condition Mask Register B allows the user to dynamically select which events will generate an interrupt.
The Receive Condition B bit (RCB) of the Interrupt Condition Register (ICR) will be set to 1 when one or more bits within the
Receive Condition Register B (RCRA) is set to 1 and the corresponding mask bits in this register is also set to 1.
Since this register is cleared (i.e. set to 0) during the reset process, all interrupts are initially masked.
ACCESS RULES
ADDRESS
READ
WRITE
0Ch
Always
Always
D7
D6
D5
D4
D3
D2
D1
D0
RESM
SILSM
EBOUM
CSEM
LSUPVM
ALSM
STM
ILSM
Bit
Symbol
Description
D0
ILSM
IDLE LINE STATE MASK: The mask bit for the Idle Line State bit (ILS) of the Receive Condition Register B
(RCRB).
D1
STM
STATE THRESHOLD MASK: The mask bit for the State Threshold bit (ST) of the Receive Condition Register B
(RCRB).
D2
ALSM
ACTIVE LINE STATE MASK: The mask bit for the Active Line State bit (ALS) of the Receive Condition Register
B (RCRB).
D3
LSUPVM
LINE STATE UNKNOWN AND PHY VALID MASK: The mask bit for the Line State Unknown and PHY Valid bit
(LSUPV) of the Receive Condition Register B (RCRB).
D4
CSEM
CASCADE SYNCHRONIZATION ERROR MASK/CONNECTION SERVICE EVENT MASK:
The mask bit for the Cascade Synchronization Error/Connection service event bit (CSE) of the Receive Condition
Register B (RCRB).
D5
EBOUM
ELASTICITY BUFFER OVERFLOW/UNDERFLOW MASK: The mask bit for the Elasticity Buffer Overflow/
Underflow bit (EBOU) of the Receive Condition Register B (RCRB).
D6
SILSM
SUPER IDLE LINE STATE MASK: The mask bit for the Super Idle Line State bit (SILS) of the Receive Condition
Register B (RCRB).
D7
RESM
RESERVED MASK: The mask bit for the Reserved bit (RES) of the Receive Condition Register B (RCRB).
57
5.0 Registers (Continued)
5.14 NOISE THRESHOLD REGISTER (NTR)
The Noise Threshold Register contains the start value for the Noise Timer. This threshold register is used in conjunction with the
Noise Prescale Threshold register for setting the maximum allowable time between entry to ILS, HLS, MLS, ALS, or NSD line
states. The Noise timer is used to implement the TNE timing requirement of PCM. The Noise timer decrements by one for every
80 x (NPTR a 1) ns in case of Noise events. As a result, the internal noise counter takes the following amount of time to reach
zero:
((NPTR a 1) x NTR a NPTR) x 80 ns
The threshold values for the Noise Counter and Noise Prescale Counter are simultaneously loaded into both counters if one of
the following conditions is true:
1. Both the Noise Counter and Noise Prescale Counter reach zero and the current Line State is either Noise Line State, Active
Line State, or Line State Unknown.
or
2. The current Line State is either Halt Line State, Idle Line State, Master Line State, Quiet Line State, or No Signal Detect.
or
3. The Noise Threshold Register or Noise Prescale Threshold Register goes through a Control Bus Interface write cycle.
In addition, the value of the Noise Prescale Threshold register is loaded into the Noise Prescale Counter if the Noise Prescale
Counter reaches zero.
The Noise Counter and Noise Prescale Counter will continue to count, without resetting or reloading the threshold values, if a
Line State change occurs and the new line state is either Noise Line State, Active Line State, or Line State Unknown.
When both the Noise Threshold Counter and Noise Counter both reach zero, the Noise Threshold bit of the Receive Condition
Register A will be set.
The recommended default value for the NTR register is 40h and for the NPTR register is F9h which corresponds to 1.3 ms as
specified in the ANSI standard.
ACCESS RULES
ADDRESS
READ
WRITE
0Dh
Always
Always
D7
D6
D5
D4
D3
D2
D1
D0
RES
NT6
NT5
NT4
NT3
NT2
NT1
NT0
Bit
Symbol
D0-D6
NT0-NT6
Description
NOISE THRESHOLD BITk0-6l: Start value for the Noise Counter.
NT0 is the Least Significant Bit (LSB).
D7
RES
RESERVED: Reserved for future use.
Note: Users are discouraged from using this bit. Write data is ignored since the reserved bit is permanently set to 0.
58
5.0 Registers (Continued)
5.15 NOISE PRESCALE THRESHOLD REGISTER (NPTR)
The Noise Prescale Threshold Register contains the start value for the Noise Prescale Timer. This threshold register is used in
conjunction with the Noise Threshold register for setting the maximum allowable time between entry to ILS, HLS, MLS, ALS, or
NSD. The Noise timer is used to implement the TNE timing requirement of PCM. The Noise Prescale threshold controls how
often the Noise timer is decremented. When the Noise Prescale Timer reaches zero, it reloads the count with the contents of the
Noise Prescale Threshold Register and also causes the Noise Timer to decrement.
The threshold values for the Noise Counter and Noise Prescale Counter are simultaneously loaded into both counters if one of
the following conditions is true:
1. Both the Noise Counter and Noise Prescale Counter reach zero and the current Line State is either Noise Line State, Active
Line State, or Line State Unknown.
or
2. The Current Line State is either Halt Line State. Idle Line State, Master Line State, Quiet Line State, or No Signal Detect
or
3. The Noise Threshold Register or Noise Prescale Threshold Register goes through a Control Bus Interface write cycle.
In addition, the value of the Noise Prescale Threshold Register is loaded into the Noise Prescale Counter if the Noise Prescale
Counter reaches zero.
The Noise Counter and Noise Prescale Counter will continue to count, without resetting or reloading the threshold values, if a
Line State change occurs and the new line state is either Noise Line State, Active Line State, or Line State Unknown.
When both the Noise Threshold Counter and Noise Counter both reach zero, the Noise Threshold bit of the Receive Condition
Register A will be set.
See the NTR register description for default value recommendations.
ACCESS RULES
ADDRESS
READ
WRITE
0Eh
Always
Always
D7
D6
D5
D4
D3
D2
D1
D0
NPT7
NPT6
NPT5
NPT4
NPT3
NPT2
NPT1
NPT0
Bit
Symbol
D0-D7
NPT0-NPT7
Description
NOISE PRESCALE THRESHOLD BITk0-7l: Start value for the Noise Prescale Timer.
NPT0 is the Least Significant Bit (LSB).
59
5.0 Registers (Continued)
5.16 CURRENT NOISE COUNT REGISTER (CNCR)
The Current Noise Count Register takes a snap-shot of the Noise Timer during every Control Bus Interface read cycle of this
register.
During a Control Bus Interface write cycle, the Control Bus Write Command Reject bit (CCR) of the Interrupt Condition Register
(ICR) will be set to 1 and will ignore a write cycle.
ACCESS RULES
ADDRESS
READ
WRITE
0Fh
Always
Write Reject
D7
D6
D5
D4
D3
D2
D1
D0
NCLSCD
CNC6
CNC5
CNC4
CNC3
CNC2
CNC1
CNC0
Bit
Symbol
D0 – D6
CNC0 – CNC6
CURRENT NOISE COUNT BIT k0–6l: Snapshot of the Noise Counter.
Description
D7
NCLSCD
NOISE COUNTER LINE STATE CHANGE DETECTION
60
5.0 Registers (Continued)
5.17 CURRENT NOISE PRESCALE COUNT REGISTER (CNPCR)
The Current Noise Prescale Count Register takes a snap-shot of the Noise Prescale Timer during every Control Bus Interface
read cycle of this register.
During a Control Bus Interface write cycle, the Control Bus Write Command Reject bit (CCR) of the Interrupt Condition Register
(ICR) will be set to 1 and will ignore a write cycle.
ACCESS RULES
ADDRESS
READ
WRITE
10h
Always
Write Reject
D7
D6
D5
D4
D3
D2
D1
D0
CNPC7
CNPC6
CNPC5
CNPC4
CNPC3
CNPC2
CNPC1
CNPC0
Bit
Symbol
D0 – D7
CNPC0–7
Description
CURRENT NOISE PRESCALE COUNT BIT k0 –7l: Snapshot of the Noise Prescale Timer.
61
5.0 Registers (Continued)
5.18 STATE THRESHOLD REGISTER (STR)
The State Threshold Register contains the start value for the State Timer. This timer is used in conjunction with the State
Prescale Timer to count the Line State duration. The State Timer will decrement every 80 ns if the State Prescale Timer is zero
and the current Line State is Halt Line State, Idle Line State, Master Line State, Quiet Line State, or No Signal Detect. The State
Timer takes
((SPTR a 1) x STR a SPTR) x 80 ns
to reach zero during a continuous line state condition.
The threshold values for the State Timer and State Prescale Timer are simultaneously loaded into both counters if one of the
following conditions is true:
1. Both the State Timer and State Prescale Timer reach zero and the current Line State is Halt Line State, Idle Line State,
Master Line State, Quiet Line State, or No Signal Detect.
or
2. A line state change occurs and the new Line State is Halt Line State, Idle Line State, Master Line State, Quiet Line State, or
No Signal Detect.
or
3. The State Threshold Register or State Prescale Threshold Register goes through a Control Bus Interface write cycle.
In addition, the value of the State Prescale Threshold Register is loaded into the State Prescale Counter if the State Prescale
Timer reaches zero.
The State Timer and State Prescale Timer will reset by reloading the threshold values, if a Line State change occurs and the
new Line State is Halt Line State, Idle Line State, Master Line State, Quiet Line State, or No Signal Detect. On detection of ALS,
NLS, or LSU the timer will not decrement.
ACCESS RULES
ADDRESS
READ
WRITE
11h
Always
Always
D7
D6
D5
D4
D3
D2
D1
D0
RES
ST6
ST5
ST4
ST3
ST2
ST1
ST0
Bit
Symbol
D0-D6
ST0-ST6
STATE THRESHOLD BITk0-6l: Start value for the State Timer.
Description
D7
RES
RESERVED: Reserved for future use.
ST0 is the Least Significant Bit (LSB).
Note: Users are discouraged from using this bit. Write data is ignored since the reserved bit is permanently set to 0.
62
5.0 Registers (Continued)
5.19 STATE PRESCALE THRESHOLD REGISTER (SPTR)
The State Prescale Threshold Register contains the start value for the State Prescale Timer. The State Prescale Timer is a down
counter. It is used in conjunction with the State Timer to count the Line State duration.
The threshold values for the State Timer and State Prescale Timer are simultaneously loaded into both timers if one of the
following conditions is true:
1. Both the State Timer and State Prescale Timer reach zero and the current Line State is Halt Line State, Idle Line State,
Master Line State, Quiet Line State, or No Signal Detect.
or
2. A Line State change occurs and the new Line State is Halt Line State, Idle Line State, Master Line State, Quiet Line State, or
No Signal Detect.
or
3. The State Threshold Register or State Prescale Threshold Register goes through a Control Bus Interface write cycle.
The State Prescale Timer will decrement every 80 ns if the current Line State is Halt Line State, Idle Line State, Master Line
State, Quiet Line State, or No Signal Detect.
ACCESS RULES
ADDRESS
READ
WRITE
12h
Always
Always
D7
D6
D5
D4
D3
D2
D1
D0
SPT7
SPT6
SPT5
SPT4
SPT3
SPT2
SPT1
SPT0
Bit
Symbol
D0 – D7
SPT0–SPT7
Description
STATE PRESCALE THRESHOLD BIT k0 –7l: Start value for the State Prescale Timer.
SPT0 is the Least Significant Bit (LSB).
63
5.0 Registers (Continued)
5.20 CURRENT STATE COUNT REGISTER (CSCR)
The Current State Count Register takes a snap-shot of the State Counter during every Control Bus Interface read cycle of this
register.
During a Control Bus Interface write cycle, the Control Bus Write Command Reject bit (CCR) of the Interrupt Condition Register
(ICR) will be set to 1 and will ignore a write cycle.
ACCESS RULES
ADDRESS
READ
WRITE
13h
Always
Write Reject
D7
D6
D5
D4
D3
D2
D1
D0
SCLSCD
CSC6
CSC5
CSC4
CSC3
CSC2
CSC1
CSC0
Bit
Symbol
D0 – D6
CSC0 – CSC6
CURRENT STATE COUNT BIT k0 –6l: Snapshot of the State Counter.
Description
D7
SCLSCD
STATE COUNTER LINE STATE CHANGE DETECTION
64
5.0 Registers (Continued)
5.21 CURRENT STATE PRESCALE COUNT REGISTER (CSPCR)
The Current State Prescale Count Register takes a snap-shot of the State Prescale Counter during every Control Bus Interface
read cycle of this register.
During a Control Bus Interface write cycle, the Control Bus Write Command Reject bit (CCR) of the Interrupt Condition Register
(ICR) will be set to 1 and will ignore a write cycle.
ACCESS RULES
ADDRESS
READ
WRITE
14h
Always
Write Reject
D7
D6
D5
D4
D3
D2
D1
D0
CSPC7
CSPC6
CSPC5
CSPC4
CSPC3
CSPC2
CSPC1
CSPC0
Bit
Symbol
D0 – D7
CSPC0–7
Description
CURRENT STATE PRESCALE COUNT k0 –7l: Snapshot of the State Prescale Counter.
65
5.0 Registers (Continued)
5.22 LINK ERROR THRESHOLD REGISTER (LETR)
The Link Error Threshold Register contains the start value for the Link Error Monitor Counter. It is an 8-bit down-counter which
decrements if link errors are detected.
When the Counter reaches 0, the Link Error Monitor Threshold Register value is loaded into the Link Error Monitor Counter and
the Link Error Monitor Threshold bit (LEMT) of the Interrupt Condition Register (ICR) is set to one.
The Link Error Monitor Threshold Register value is also loaded into the Link Error Monitor Counter during every Control Bus
Interface write cycle of LETR.
The counter is initialized to 0 during the reset process (i.e. E RST e GND).
ACCESS RULES
ADDRESS
READ
WRITE
15h
Always
Always
D7
D6
D5
D4
D3
D2
D1
D0
LET7
LET6
LET5
LET4
LET3
LET2
LET1
LET0
Bit
Symbol
D0 – D7
LET0 – LET7
Description
LINK ERROR THRESHOLD BIT k0–7l: Start value for the Link Error Monitor Counter.
LET0 is the Least Significant Bit (LSB).
66
5.0 Registers (Continued)
5.23 CURRENT LINK ERROR COUNT REGISTER (CLECR)
The Current Link Error Count Register takes a snap-shot of the Link Error Monitor Counter during every Control Bus Interface
read cycle of this register.
During a Control Bus Interface write cycle, the Control Bus Write Command Reject bit (CCR) of the Interrupt Condition Register
(ICR) will be set to 1 and will ignore a write cycle.
ACCESS RULES
ADDRESS
READ
WRITE
16h
Always
Write Reject
D7
D6
D5
D4
D3
D2
D1
D0
LEC7
LEC6
LEC5
LEC4
LEC3
LEC2
LEC1
LEC0
Bit
Symbol
D0 – D7
LEC0–LEC7
Description
LINK ERROR COUNT BIT k0 –7l: Snapshot of the Link Error Monitor Counter.
67
5.0 Registers (Continued)
5.24 USER DEFINABLE REGISTER (UDR)
The User Definable Register is used to monitor and control events which are external to the PLAYER a device.
The value of the Sense Bits reflect the asserted/deasserted state of their corresponding Sense pins. On the other hand, the
Enable bits assert/deassert the Enable pins.
Note: SB2 and EB2 are only effective for the DP83257.
ACCESS RULES
ADDRESS
READ
WRITE
17h
Always
Always
D7
D6
D5
D4
D3
D2
D1
D0
RES
EB2
RES
SB2
EB1
EB0
SB1
SB0
Bit
Symbol
D0
SB0
SENSE BIT 0: This bit is set to 1 if the Sense Pin 0 (SP0) is asserted (i.e. SP0 e VCC) for a minimum amount of
time. Once the asserted signal is latched, Sense Bit 0 can only be cleared through the Control Bus Interface, even
if the signal is deasserted. This ensures that the Control Bus Interface will record the source of events which can
cause interrupts in a traceable manner.
Description
D1
SB1
SENSE BIT 1: This bit is set to 1 if the Sense Pin 1 (SP1) is asserted (i.e. SP1 e VCC) for a minimum amount of
time. Once the asserted signal is latched, Sense Bit 1 can only be cleared through the Control Bus Interface, even
if the signal is deasserted. This ensures that the Control Bus Interface will record the source of events which can
cause interrupts in a traceable manner.
D2
EB0
ENABLE BIT 0: The Enable Bit 0 allows control of external logic through the Control Bus Interface. The User
Definable Enable Pin 0 (EP0) is asserted/deasserted by this bit.
0:
1:
D3
EB1
ENABLE BIT 1: This bit allows control of external logic through the Control Bus Interface. The User Definable
Enable Pin 0 (EP0) is asserted/deasserted by this bit.
0:
1:
D4
SB2
D5
RES
D6
EB2
EP0 is deasserted (i.e. EP0 e GND).
EP0 is asserted (i.e. EP0 e VCC).
EP1 is deasserted (i.e. EP1 e GND).
EP1 is asserted (i.e. EP1 e VCC).
SENSE BIT 2: This bit is set to 1 if the Sense Pin 2 (SP2) is asserted (i.e. SP2 e VCC) for a minimum amount of
time. Once the asserted signal is latched, Sense Bit 2 can only be cleared through the Control Bus Interface, even
if the signal is deasserted. This ensures that the Control Bus Interface will record the source of events which can
cause interrupts in a traceable manner.
Note: SB2 and EB2 are only effective for the DP83257.
RESERVED: Reserved for future use. The reserved bit is set to 0 during the initialization process
(i.e. E RST e GND).
Note: Users are discouraged from using this bit. It may be set or cleared without any effects to the functionality of the PLAYER a device.
ENABLE BIT2: The Enable Bit 2 allows control of external logic through the Control Bus Interface. The User
Definable Enable Pin 2 (EP2) is asserted/deasserted by this bit.
Note: SB2 and EB2 are only effective for the DP83257.
0:
1:
D7
RES
EP2 is deasserted (i.e. EP2 e GND).
EP2 is asserted (i.e. EP2 e VCC).
RESERVED: Reserved for future use. The reserved bit is set to 0 during the initialization process
(i.e. E RST e GND).
Note: Users are discouraged from using this bit. It may be set or cleared without any effects to the functionality of the PLAYER a device.
68
5.0 Registers (Continued)
5.25 DEVICE ID REGISTER (IDR)
The Device ID Register contains the binary equivalent of the revision number for this device. It can be used to ensure proper
software and hardware versions are matched.
During a Control Bus Interface write cycle, the Control Bus Write Command Register bit (CCR) of the Interrupt Condition
Register (ICR) will be set to 1, and will ignore write cycle.
REVISION TABLE
IDR
(hex)
DEVICE DESCRIPTION
10
11
PLAYER a Revision A
PLAYER a Revision B
ACCESS RULES
ADDRESS
READ
WRITE
18h
Always
Write Reject
D7
D6
D5
D4
D3
D2
D1
D0
DID7
DID6
DID5
DID4
DID3
DID2
DID1
DID0
Bit
Symbol
D0 – D3
DID0–DID3
DEVICE ID BIT k0-3l: Circuit enhancement revision number. Bit 3 is the MSB. The initial revision of the
PLAYER a is equal to 0 and enhancements will increment this number.
Description
D4 – D7
DID4–DID7
DEVICE ID BIT k4-7l: Architecture level of the PHY device. Bit 7 is the MSB. The original PLAYER
device was equal to 0 and the PLAYER a is equal to 1. This number will only be incremented after a
significant architectural change.
69
5.0 Registers (Continued)
5.26 CURRENT INJECTION COUNT REGISTER (CIJCR)
The Current Injection Count Register takes a snap-shot of the Injection Counter during every Control Bus Interface read cycle of
this register.
During a Control Bus Interface write cycle, the Control Bus Write Command Reject bit (CCR) of the Interrupt Condition Register
(ICR) will be set to 1 and will ignore a write cycle.
The Injection Counter is an 8-bit down-counter which decrements every 80 ns.
The counter is active only during One Shot or Periodic Injection Modes (i.e. Injection Controlk1:0l bits (ICk1:0l) of the
Current Transmit State Register (CTSR) are set to either 01 or 10).
The Injection Threshold Register (IJTR) value is loaded into the Injection Counter when the counter reaches zero and during
every Control Bus Interface write cycle of IJTR.
The counter is initialized to 0 during the reset process (i.e. E RST e GND).
ACCESS RULES
ADDRESS
READ
WRITE
19h
Always
Write Reject
D7
D6
D5
D4
D3
D2
D1
D0
IJC7
IJC6
IJC5
IJC4
IJC3
IJC2
IJC1
IJC0
Bit
D0 – D7
Symbol
IJC0 – IJC7
Description
INJECTION COUNT BITk0-7l: Current value of the Injection Counter.
IJC0 is the Least Significant Bit (LSB).
70
5.0 Registers (Continued)
5.27 INTERRUPT CONDITION COMPARISON REGISTER (ICCR)
The Interrupt Condition Comparison Register ensures that the Control Bus must first read a bit modified by the PLAYER a
device before it can be written to by the Control Bus Interface.
The current state of the Interrupt Condition Register (ICR) is automatically written into the Interrupt Condition Comparison
Register (i.e. ICCR e ICR) during a Control Bus Interface read-cycle of ICR.
During a Control Bus Interface write cycle, the PLAYER a device will set the Conditional Write Inhibit bit (CWI) of the Interrupt
Condition Register (ICR) to 1 and disallow the setting or clearing of a bit within ICR when the value of a bit in ICR differs from the
value of the corresponding bit in the interrupt Condition Comparison Register.
ACCESS RULES
ADDRESS
READ
WRITE
1Ah
Always
Always
D7
D6
D5
D4
D3
D2
D1
D0
UDIC
RCBC
RCAC
LEMTC
CWIC
CCRC
CPEC
DPEC
Bit
Symbol
D0
DPEC
PHYÐREQUEST DATA PARITY ERROR COMPARISON: The comparison bit for the PHYÐRequest Data Parity
Error bit (DPE) of the Interrupt Condition Register (ICR).
Description
D1
CPEC
CONTROL BUS DATA PARITY ERROR COMPARISON: The comparison bit for the Control Bus Data Parity Error
bit (CPE) of the Interrupt Condition Register (ICR).
D2
CCRC
CONTROL BUS WRITE COMMAND REJECT COMPARISON: The comparison bit for the Control Bus Write
Command Reject bit (CCR) of the Interrupt Condition Register (ICR).
D3
CWIC
CONDITIONAL WRITE INHIBIT COMPARISON: The comparison bit for the Conditional Write Inhibit bit (CWI) of
the Interrupt Condition Register (ICR).
D4
LEMTC
LINK ERROR MONITOR THRESHOLD COMPARISON: The comparison bit for the Link Error Monitor Threshold
bit (LEMT) of the Interrupt Condition Register (ICR).
D5
RCAC
RECEIVE CONDITION A COMPARISON: The comparison bit for the Receive Condition A bit (RCA) of the
Interrupt Condition Register (ICR).
D6
RCBC
RECEIVE CONDITION B COMPARISON: The comparison bit for the Receive Condition B bit (RCB) of the
Interrupt Condition Register (ICR).
D7
UDIC
USER DEFINABLE INTERRUPT COMPARISON: The comparison bit for the User Definable Interrupt bit (UDIC) of
the Interrupt Condition Register (ICR).
71
5.0 Registers (Continued)
5.28 CURRENT TRANSMIT STATE COMPARISON REGISTER (CTSCR)
The Current Transmit State Comparison Register ensures that the Control Bus must first read a bit modified by the PLAYER a
device before it can be written to by the Control Bus Interface.
The current state of the Current Transmit State Register (CTSR) is automatically written into the Current Transmit State
Comparison Register A (i.e. CTSCR e CTSR) during a Control Bus Interface read cycle of CTSR.
During a Control Bus Interface write cycle, the PLAYER a device will set the Conditional Write Inhibit bit (CWI) of the Interrupt
Condition Register (ICR) to 1 and disallow the setting or clearing of a bit within the CTSR when the value of a bit in the CTSR
differs from the value of the corresponding bit in the Current Transmit State Comparison Register.
ACCESS RULES
ADDRESS
READ
WRITE
1Bh
Always
Always
D7
D6
D5
D4
D3
D2
D1
D0
RESC
PRDPEC
SEC
IC1C
IC0C
TM2C
TM1C
TM0C
Bit
Symbol
D0
TM0C
TRANSMIT MODE k0l COMPARISON: The comparison bit for the Transmit Mode k0l bit (TM0) of the
Current Transmit State Register (CTSR).
Description
D1
TM1C
TRANSMIT MODE k1l COMPARISON: The comparison bit for the Transmit Mode k1l bit (TM1) of the
Current Transmit State Register (CTSR).
D2
TM2C
TRANSMIT MODE k2l COMPARISON: The comparison bit for the Transmit Mode k2l bit (TM2) of the
Current Transmit State Register (CTSR).
D3
IC0C
INJECTION CONTROL k0l COMPARISON: The comparison bit for the Injection Control k0l bit (IC0) of the
Current Transmit State Register (CTSR).
D4
IC1C
INJECTION CONTROL k1l COMPARISON: The comparison bit for the Injection Control k1l bit (IC1) of the
Current Transmit State Register (CTSR).
D5
SEC
SMOOTHER ENABLE COMPARISON: The comparison bit for the Smoother Enable bit (SE) of the Current
Transmit State Register (CTSR).
D6
PRDPEC
PHYÐREQUEST DATA PARITY ENABLE COMPARISON: The comparison bit for the PHYÐRequest Data
Parity Enable bit (PRDPE) of the Current Transmit State Register (CTSR).
D7
RESC
RESERVED COMPARISON: The comparison bit for the Reserved bit (RES) of the Current Transmit State
Register (CTSR).
72
5.0 Registers (Continued)
5.29 RECEIVE CONDITION COMPARISON REGISTER A (RCCRA)
The Receive Condition Comparison Register A ensures that the Control Bus must first read a bit modified by the PLAYER a
device before it can be written to by the Control Bus Interface.
The current state of RCRA is automatically written into the Receive Condition Comparison Register A (i.e. RCCRA e RCRA)
during a Control Bus Interface read cycle of RCRA.
During a Control Bus Interface write cycle, the PLAYER a device will set the Conditional Write Inhibit bit (CWI) of the Interrupt
Condition Register (ICR) to 1 and prevent the setting or clearing of a bit within RCRA when the value of a bit in RCRA differs
from the value of the corresponding bit in the Receive Condition Comparison Register A.
ACCESS RULES
ADDRESS
READ
WRITE
1Ch
Always
Always
D7
D6
D5
D4
D3
D2
D1
D0
LSUPIC
LSCC
NTC
NLSC
MLSC
HLSC
QLSC
NSDC
Bit
Symbol
D0
NSDC
NO SIGNAL DETECT COMPARISON: The comparison bit for the No Signal Detect bit (NSD) of the Receive
Condition Register A (RCRA).
Description
D1
QLSC
QUIET LINE STATE COMPARISON: The comparison bit for the Quiet Line State bit (QLS) of the Receive
Condition Register A (RCRA).
D2
HLSC
HALT LINE STATE COMPARISON: The comparison bit for the Halt Line State bit (HLS) of the Receive Condition
Register A (RCRA).
D3
MLSC
MASTER LINE STATE COMPARISON: The comparison bit for the Master Line State bit (MLS) of the Receive
Condition Register A (RCRA).
D4
NLSC
NOISE LINE STATE COMPARISON: The comparison bit for the Noise Line State bit (NLS) of the Receive
Condition Register A (RCRA).
D5
NTC
NOISE THRESHOLD COMPARISON: The comparison bit for the Noise Threshold bit (NT) of the Receive
Condition Register A (RCRA).
D6
LSCC
LINE STATE CHANGE COMPARISON: The comparison bit for the Line State Change bit (LSC) of the Receive
Condition Register A (RCRA).
D7
LSUPIC
LINE STATE UNKNOWN AND PHY INVALID COMPARISON: The comparison bit for the Line State Unknown
and PHY Invalid bit (LSUPI) of the Receive Condition Register A (RCRA).
73
5.0 Registers (Continued)
5.30 RECEIVE CONDITION COMPARISION REGISTER B (RCCRB)
The Receive Condition Comparison Register B ensures that the Control Bus must first read a bit modified by the PLAYER a
device before it can be written to by the Control Bus Interface.
The current state of RCRB is automatically written into the Receive Condition Comparison Register B (i.e. RCCRB e RCRB)
during a Control Bus Interface read cycle RCRB.
During a Control Bus Interface write cycle, the PLAYER a device will set the Conditional Write Inhibit bit (CWI) of the Interrupt
Condition Register (ICR) to 1 and prevent the setting or clearing of a bit within RCRB when the value of a bit in RCRB differs
from the value of the corresponding bit in the Receive Condition Comparison Register B.
ACCESS RULES
ADDRESS
READ
WRITE
1Dh
Always
Always
D7
D6
D5
D4
D3
D2
D1
D0
RESC
SILSC
EBOUC
CSEC
LSUPVC
ALSC
STC
ILSC
Bit
Symbol
D0
ILSC
IDLE LINE STATE COMPARISON: The comparison bit for the Idle Line State bit (ILS) of the Receive Condition
Register B (RCRB).
Description
D1
STC
STATE THRESHOLD COMPARISON: The comparison bit for the State Threshold bit (ST) of the Receive
Condition Register B (RCRB).
D2
ALSC
ACTIVE LINE STATE COMPARISON: The comparison bit for the Active Line State bit (ALS) of the Receive
Condition Register B (RCRB).
D3
LSUPVC
LINE STATE UNKNOWN AND PHY VALID COMPARISON: The comparison bit for the Line State Unknown and
PHY Valid bit (LSUPV) of the Receive Condition Register B (RCRB).
D4
CSEC
CONNECTION SERVICE EVENT COMPARISON / CASCADE SYNCHRONIZATION ERROR: The comparison
bit for the Cascade Synchronization Error/Connection Service Event bit (CSE) of the Receive Condition Register
B (RCRB).
D5
EBOUC
ELASTICITY BUFFER OVERFLOW / UNDERFLOW COMPARISON: The comparison bit for the Elasticity Buffer
Overflow/Underflow bit (EBOU) of the Receive Condition Register B (RCRB).
D6
SILSC
SUPER IDLE LINE STATE COMPARISON: The comparison bit for the Super Idle Line State bit (SILS) of the
Receive Condition Register B (RCRB).
D7
RESC
RESERVED COMPARISON: The comparison bit for the Reserved bit (RES) of the Receive Condition Register B
(RCRB).
74
5.0 Registers (Continued)
5.31 MODE REGISTER 2 (MODE2)
The Mode Register 2 (MODE2) is used to configure the PLAYER a device.
The register is used to software reset the chip, setup data parity, and enable scrubbing functions.
Note: This register can not be written to during reset.
ACCESS RULES
ADDRESS
READ
WRITE
1Eh
Always
Conditional
D7
D6
D5
D4
D3
D2
D1
D0
ESTC
RES
CLKSEL
RES
RES
RES
CBPE
PHYRST
Bit
D0
Symbol
PHYRST
Description
PLAYER RESET: This bit can be used as a master software reset of the PLAYER function within the
PLAYER a device. The clock distribution and recovery sections of the chip are not affected by this reset.
The PLAYER a automatically clears this bit 32 byte time after its assertion to indicate that the reset action
has been completed.
This bit can be set through a C-Bus write, but can only be cleared by the PLAYER a .
D1
CBPE
C-Bus Parity Enable: This bit disables or enables parity checking on C-Bus data. When this bit is set to 0, no
parity checking is done. When the bit is set to 1, parity checking is enabled during a C-Bus write cycle. Should
a mismatch occur, the C-Bus Data Parity Error (ICR.CPE) bit will be set and the corresponding C-Bus access
is discarded.
C-Bus data parity is always generated during a C-Bus read cycle.
D2 – D4
RES
RESERVED: Reserved for future use.
D5
CLKSEL
CLOCK SELECT: This bit controls the frequency of the CLK16 output. It resets to 0 which sets the CLK16
output to a 15.625 MHz frequency. When set to 1 a 31.25 MHz frequency is generated.
Note: When the value of this bit is changed, no glitches appear on the CLK16 output due to the frequency change.
D6
RES
RESERVED: Reserved for future use.
D7
ESTC
ENABLE SCRUBBING on TRIGGER CONDITIONS: When ESTC is set to 1 and a Trigger Condition occurs
(as set in the TDR register), the Trigger Transition Configuration Register (TTCR) is loaded into the
Configuration Register (CR) and scrubbing is started on all indicate ports that have changed.
Scrubbing is accomplished by sending out 2 PhyÐInvalid symbols followed by ‘‘scrub’’symbol pairs for a time
defined by the Scrub Timer Threshold register.
75
5.0 Registers (Continued)
5.32 CMT CONDITION COMPARISON REGISTER (CMTCCR)
The CMT Condition Comparison Register (CMTCR) ensures that the Control Bus must first read a bit modified by the PLAYER a
device before it can be written to by the Control Bus Interface.
The current state of the CMT Condition Register (CMTCR) is automatically written into the CMT Condition Comparison Register
(CMTCR) (i.e. CMTCCR e CMTCR) during a Control Bus Interface read-cycle of CMTCR.
During a Control Bus Interface write cycle, the PLAYER a device will set the Conditional Write Inhibit bit (CWI) of the Interrupt
Control Register (ICR) to 1 and disallow the setting or clearing of a bit within the CMTCR when the value of a bit in the CMTCR
differs from the value of the corresponding bit in the CMT Condition Comparison Register.
ACCESS RULES
ADDRESS
READ
WRITE
1Fh
Always
Always
D7
D6
D5
D4
D3
D2
D1
D0
TCOC
STEC
RES
RES
RES
RES
RES
RES
Bit
Symbol
Description
D0-D5
RES
RESERVED: Reserved for future use.
D6
STEC
SCRUB TIMER EXPIRED COMPARISON: The comparison bit for the Scrub Timer Expire bit (STE) of the CMT
Condition Register (CMTCR).
D7
TCOC
TRIGGER CONDITION OCCURRED COMPARISON: The comparison bit for the Trigger Condition Occurred
(TCO) bit of the CMT Condition Register (CMTCR).
76
5.0 Registers (Continued)
5.33 CMT CONDITION REGISTER (CMTCR)
The CMT Condition Register maintains a history of all CMT events and actions performed. The corresponding CMT Condition
Mask Register (CMTCMR) can be used to generate an interrupt. When the bits in both the CMTCMR and CMTCR are set, the
Receive Condition Register B’s Connection Service Event (RCRB.CSE) bit will be set.
ACCESS RULES
ADDRESS
READ
WRITE
20h
Always
Conditional
D7
D6
D5
D4
D3
D2
D1
D0
TCO
STE
RES
RES
RES
RES
RES
RES
Bit
Symbol
D0-D5
RES
D6
STE
Description
RESERVED: Reserved for future use.
SCRUB TIMER EXPIRED: This bit is set to 1 when the Scrub Timer expires.
Note: When STE is set, the Configuration Register (CR) is protected.
D7
TCO
TRIGGER CONDITION OCCURRED: This bit is set to 1 when a trigger condition is met. When a trigger occurs,
the values in the Trigger Transmit Mode (TDR.TTM2-0) are loaded into the Current Transmit Mode Register
(CTSR.TM2-0).
Note: When TCO is set, the Current Transmit State Register (CTSR) is protected.
77
5.0 Registers (Continued)
5.34 CMT CONDITION MASK REGISTER (CMTCMR)
This is the mask register for the CMT Condition Register (CMTCR). When the bits in both the CMTCMR and CMTCR are set, the
Receive Condition Register B’s Connection Service Event (RCRB.CSE) bit will be set.
ACCESS RULES
ADDRESS
READ
WRITE
21h
Always
Always
D7
D6
D5
D4
D3
D2
D1
D0
TCOM
STEM
RES
RES
RES
RES
RES
RES
Bit
Symbol
Description
D0-D5
RES
RESERVED: Reserved for future use.
D6
STEM
SCRUB TIMER EXPIRED MASK: The mask bit for the Scrub Timer Expired (STE) bit of the CMT Condition
Register (CMTCR).
D7
TCOM
TRIGGER CONDITION OCCURRED MASK: The mask bit for the Trigger Condition Occurred (TCO) bit of the
CMT Condition Register (CMTCR).
78
5.0 Registers (Continued)
5.35 RESERVED REGISTERS 22H–23H (RR22H– RR23H)
This register is reserved for future use.
DO NOT ACCESS THIS REGISTER
ACCESS RULES
ADDRESS
READ
WRITE
22h –23h
Always
DO NOT WRITE
79
5.0 Registers (Continued)
5.36 SCRUB TIMER THRESHOLD REGISTER (STTR)
This is the threshold value of the internal scrub timer. It has a resolution of 40.96 ms and a maximum value of E 10 ms. When
the scrub timer reaches zero, the Scrub Timer Expired (CMTCR.STE) bit is set.
Scrubbing is initiated when MODE2.ESTC e 1 and a trigger condition occurs.
Writing to STTR during scrubbing will not affect the scrubbing action.
ACCESS RULES
ADDRESS
READ
WRITE
24h
Always
Always
D7
D6
D5
D4
D3
D2
D1
D0
STT7
STT6
STT5
STT4
STT3
STT2
STT1
STT0
Bit
D0 – D7
Symbol
STT0 – STT7
Description
SCRUB TIMER THRESHOLD BITk0-7l: Scrub Timer threshold.
STT0 is the Least Significant Bit (LSB).
80
5.0 Registers (Continued)
5.37 SCRUB TIMER VALUE REGISTER (STVR)
This is a snap-shot of the current value of the upper 8 bits of the scrub timer.
During a Control Bus Interface write cycle, the Control Bus Write Command Reject bit (CCR) of the Interrupt Condition Register
(ICR) will be set to 1 and will ignore a write cycle.
ACCESS RULES
ADDRESS
READ
WRITE
25h
Always
Write Reject
D7
D6
D5
D4
D3
D2
D1
D0
STV7
STV6
STV5
STV4
STV3
STV2
STV1
STV0
Bit
Symbol
D0 – D7
STV0–STV7
Description
SCRUB TIMER VALUE BITk0-7l: Snap-shot of the scrub timer.
STV0 is the Least Significant Bit (LSB).
81
5.0 Registers (Continued)
5.38 TRIGGER DEFINITION REGISTER (TDR)
This register determines which events cause a trigger transition and which transmit mode is entered when a trigger transition is
detected. The trigger transmit modes are the same as those found in the Current Transmit State Register (CTSR), and are
loaded from the TDR into the CTSR when any of the selected trigger conditions occur. When a trigger condition occurs
CMTCR.TCO is set.
The Trigger Definition Register is useful to implement the strict PCÐReact time requirement.
ACCESS RULES
ADDRESS
READ
WRITE
26h
Always
Always
D7
D6
D5
D4
D3
D2
D1
D0
TONT
TOQLS
TOHLS
TOMLS
TOSILS
TTM2
TTM1
TTM0
Bit
Symbol
D0,
D1,
D2
TTM0,
TTM1,
TTM2
Description
TRIGGER TRANSMIT MODE k0, 1, 2l: These bits select one of 6 transmission modes to be loaded into the
Current Transmit State Register (CTSR) when a trigger condition is detected. The trigger condition is selected by
the upper 5 bits of this register.
TTM2
TTM1
0
0
TTM0
0
Active Transmit Mode (ATM): Normal transmission of incoming PHY Request data.
0
0
1
Idle Transmit Mode (ITM): Transmission of Idle symbol pairs (11111 11111).
0
1
0
Off Transmit Mode (OTM): Transmission of Quiet symbol pairs (00000 00000) and
deassertion of the PMD transmitter Enable pin (TXE).
0
1
1
Reserved: Reserved for future use. Users are discouraged from using this transmit
mode. If selected, however, the transmitter will generate Quiet symbol pairs
(00000 00000).
1
0
0
Master Transmit Mode (MTM): Transmission of Halt and Quiet symbol pairs
(00100 00000).
1
0
1
Halt Transmit Mode (HTM): Transmission of Halt symbol pairs (00100 00100).
1
1
0
Quiet Transmit Mode (QTM): Transmission of Quiet symbol pairs (00000 00000).
1
1
1
Reserved: Reserved for future use. Users are discouraged from using this transmit
mode. If selected, however, the transmitter will generate Quiet symbol pairs
(00000 00000).
D3
TOSILS
TRIGGER ON SILS: Trigger when SILS is received.
D4
TOMLS
TRIGGER ON MLS: Trigger when MLS is received.
D5
TOHLS
TRIGGER ON HLS: Trigger when HLS is received.
D6
TOQLS
TRIGGER ON QLS (or NSD): Trigger when QLS is received.
D7
TONT
TRIGGER ON Noise Threshold: Trigger when Noise Threshold is reached (Current Noise Register e 0).
82
5.0 Registers (Continued)
5.39 TRIGGER TRANSITION CONFIGURATION REGISTER (TTCR)
The Trigger Transition Configuration Register holds the configuration switch setting to be loaded into the Configuration Register
(CR) when a trigger transition takes place. When scrubbing is enabled, scrubbing is performed for a period of time indicated by
the Scrub Timer Threshold Register (STTR).The register bit descriptions for the Configuration Register and, therefore, the
Trigger Transition Configuration Register are reprinted below.
ACCESS RULES
ADDRESS
READ
WRITE
27h
Always
Always
D7
D6
D5
D4
D3
D2
D1
D0
BIE
AIE
TRS1
TRS0
BIS1
BIS0
AIS1
AIS0
Bit
D0, D1
Symbol
AIS0, AIS1
Description
AÐINDICATE SELECTOR k0, 1l: The AÐIndicate Selector k0, 1l bits selects one of the four
Configuration Switch data buses for the A Indicate output port (AIP, AIC, AIDk7:0l).
Ð
AIS1
0
0
1
1
D2, D3
BIS0, BIS1
AIS0
0
1
0
1
PHY Invalid Bus
Receiver Bus
AÐRequest Bus
BÐRequest Bus
BÐINDICATE SELECTOR k0, 1l: The BÐIndicate Selector k0, 1l bits selects one of the four
Configuration Switch data buses for the BÐIndicate output port (BIP, BIC, BIDk7:0l).
BIS1
0
0
1
1
BIS0
0
1
0
1
PHY Invalid Bus
Receiver
AÐRequest Bus
BÐRequest Bus
Note: Even though this bit can be set and/or cleared in the DP83256 (for single path stations), it will not affect any I/Os since the
DP83256 does not offer a BÐIndicate port.
D4, D5
TRS0, TRS1
TRANSMIT REQUEST SELECTOR k0, 1l: The Transmit Request Selector k0, 1l bits selects one of
the four Configuration Switch data buses for the input to the Transmitter Block.
TRS1
0
0
1
1
TRS0
0
1
0
1
PHY Invalid Bus
Receiver Bus
AÐRequest Bus
BÐRequest Bus
Note: If the PLAYER a device is in Active Transmit Mode (i.e. the Transmit Mode bits (TM k 2:0 l ) of the Current Transmit State
Register (CTSR) are set to 00) and the PHY Invalid Bus is selected, then the PLAYER a device will transmit continuous Idle
symbols due to the Repeat Filter.
D6
AIE
AÐINDICATE ENABLE:
0: Disables the AÐIndicate output port. The AÐIndicate port pins will be tri-stated when the port is
disabled.
1: Enables the AÐIndicate output port (AIP, AIC, AIDk7:0l).
D7
BIE
BÐINDICATE ENABLE:
0: Disables the BÐIndicate output port. The BÐIndicate port pins will be tri-stated when the port is
disabled.
1: Enables the BÐIndicate output port (BIP, BIC, BIDk7:0l).
Note: Even though this bit can be set and/or cleared in the DP83256 (for single path stations), it will not affect any I/Os since the
DP83256 does not offer a BÐIndicate port.
83
5.0 Registers (Continued)
5.40 RESERVED REGISTERS 28H-3AH (RR28H-RR3AH)
These registers are reserved for future use.
DO NOT ACCESS THESE REGISTERS
ACCESS RULES
ADDRESS
READ
WRITE
28h – 3Ah
Always
DO NOT WRITE
84
5.0 Registers (Continued)
5.41 CLOCK GENERATION MODULE REGISTER (CGMREG)
This register is used to enable or disable the 125 MHz ECL Transmit clock outputs. These outputs are not required for use in a
standard FDDI board implementation and are disabled by default to reduce high frequency noise.
These TXC outputs are included for support of alternate FDDI PMDs, such as unshielded twisted pair copper cable.
DO NOT WRITE TO RESERVED REGISTER BITS. Writes to reserved register bits could prevent proper device operation.
Therefore, read the register first, and then write it back with the non-reserved bits set to the desired value.
ACCESS RULES
ADDRESS
READ
WRITE
3Bh
Always
Always
D7
D6
D5
D4
D3
D2
D1
D0
RES
RES
FLTREN
RES
TXCE
RES
RES
RES
Bit
Symbol
Description
D0-D2
RES
RESERVED BITS: DO NOT CHANGE THE VALUE OF THESE BITS. Changes to reserved register bits could
prevent proper device operation.
D3
TXCE
TRANSMIT CLOCK ENABLE: When bit is set to 1, 125 MHz ECL TXC outputs are enabled. When this bit is
reset to 0, TXC outputs are disabled. TXC outputs are disabled on reset.
Note: TXC clocks are only available on the 160-pin DP83257 PLAYER a device.
D4
RES
RESERVED BITS: DO NOT CHANGE THE VALUE OF THESE BITS. Changes to reserved register bits could
prevent proper device operation.
D5
FLTREN
FILTER ENABLE: When bit is set to 1, the internal loop filter node is connected to the LPFLTR pin for
diagnostic viewing. This bit is reset to 0 by default, which disconnects the filter node from the LPFLTR pin.
Note: In normal operation this bit should be disabled ( e 0).
D6-D7
RES
RESERVED BITS: DO NOT CHANGE THE VALUE OF THESE BITS. Changes to reserved register bits could
prevent proper device operation.
85
5.0 Registers (Continued)
5.42 ALTERNATE PMD REGISTER (APMDREG)
This register is used to enable or disable the Alternate PMD inputs and ouputs. These signals are not required for use in FDDI
board implementations that do not require a scrambler that is external to the PLAYER a device. The actual interface consists of
the signal pairs RXCÐOUT, RXDÐOUT, RXCÐIN, and RXDÐIN.
The interface is disabled by default and should only be enabled if it is being used. Note that Long Internal Loopback should not
be used when the Alternate PMD Interface is enabled.
DO NOT WRITE TO RESERVED REGISTER BITS. Writes to reserved register bits could prevent proper device operation.
Therefore, read the register first, and then write it back with the non-reserved bits set to the desired value.
Note: The Alternate PMD Interface pins are only available on the 100-pin DP83256-AP and 160-pin DP83257 PLAYER a devices. The Alternate PMD Interface is
disabled on reset.
ACCESS RULES
ADDRESS
READ
WRITE
3Ch
Always
Always
D7
D6
D5
D4
D3
D2
D1
D0
RES
RES
RES
RES
APMDEN
RES
RES
RES
Bit
Symbol
Description
D0 – D2
RES
RESERVED BITS: DO NOT CHANGE THE VALUE OF THESE BITS. Changes to reserved register bits could
prevent proper device operation.
D3
APMDEN
ALTERNATE PMD ENABLE: When bit is set to 1, the Alternate PMD Interface is enabled. When this bit is
reset to 0, the Alternate PMD Interface is disabled.
The Alternate PMD Interface consists of the following extra ECL signal pairs
RXCÐOUT, RXDÐOUT, RXCÐIN, and RXDÐIN.
In some alternate PMD implementations it may also be necessary to use the 125 MHz Transmit Clock
signals (TXC). The TXC outputs must be separately enabled by the TXCE bit in the CGMREG register.
Note: The Alternate PMD Interface pins are only available on the 100-pin DP83256-AP and 160-pin DP83257 PLAYER a devices. The
Alternate PMD Interface is disabled on reset.
D4 – D7
RES
RESERVED BITS: DO NOT CHANGE THE VALUE OF THESE BITS. Changes to reserved register bits could
prevent proper device operation.
86
5.0 Registers (Continued)
5.43 GAIN REGISTER (GAINREG)
The Gain Register contains the settings for the CGM’s on-chip programmable loop filter. For optimal jitter performance on the
revision A and B PLAYER a device’s Filter Position 4 should be used. The user should check that the IDR register is equal to
revision A or B (10h or 11h) before changing the filter setting as later revisions will default to the correct setting which may be a
different filter position number.
Pseudo Code Programming Example:
Care must be taken when changing the settings of the on-chip programmable loop filter. The filter should only be set to the
recommended value and the additional bits in the Gain Register must not be altered. Alteration of the reserved bits in the Gain
Register may result in improper PLAYER a device operation.
The following pseudo code outlines the proper procedure for setting the Gain Register loop filter settings to the correct value.
// Register names and constants are all in UPPERCASE
//
//
#define REV B 0x11
#define REV A 0x10
#define LOOP MASK 0x1F
#define NEW LOOP 0x40
if (IDR k4 REV B) À
temp 4 GAIN REG
temp 4 temp & LOOP MASK
temp 4 temp l NEW LOOP
GAIN REG 4 temp
Ó
else ÀDo NothingÓ
ACCESS RULES
ADDRESS
READ
WRITE
3Dh
Always
Always
D7
D6
D5
D4
D3
D2
D1
D0
FILT2
FILT1
FILT0
RES
RES
RES
RES
RES
Bit
Symbol
Description
D0 – D4
RES
RESERVED: Do not alter these bits. The device may cease to operate properly if these bits are
changed.
D5 – D7
FILT0,
FILT1,
FILT2
FILTER SELECTION k0, 1, 2l: The Filter Selection k0, 1, 2l bits select one of five on-chip CGM
loop filters.
Note: Filter combinations that are not specified or recommended should not be used and may result in non-optimal device
performance.
FILT2
1
1
0
FILT1
1
1
0
FILT0
0
1
0
0
0
0
1
1
0
FP0: Filter Position 0.
FP1: Filter Position 1.
FP2: Filter Position 2. This is the filter selected after reset on the
revision A and B PLAYER a devices.
FP3: Filter Position 3.
FP4: Filter Position 4. This is the recommended filter position for
the revision A and B PLAYER a devices.
87
5.0 Registers (Continued)
5.44 RESERVED REGISTERS 3EH-3FH (RR3EH-RR3FH)
These registers are reserved for future use.
DO NOT ACCESS THESE REGISTERS
ACCESS RULES
ADDRESS
READ
WRITE
3Eh – 3Fh
Always
DO NOT WRITE
88
6.0 Signal Descriptions
6.1 DP83256VF PIN DESCRIPTIONS
The pin descriptions for the DP83256VF are divided into 5 functional interfaces: PMD Interface, PHY Port Interface, Control Bus
Interface, Clock Interface, and Miscellaneous Interface.
For a Pinout Summary list, refer to Table 8-1 and Figure 8-1 , DP83256VF 100-Pin JEDEC Metric PQFP Pinout.
PMD INTERFACE
The PMD Interface consists of I/O signals used to connect the PLAYER a device to the Physical Medium Dependant (PMD)
sublayer.
Symbol
Pin Ý
I/O
PMID a
PMIDb
39
38
I
PMD Indicate Data: Differential, 100k ECL, 125 Mbps serial data input signals from the PMD receiver.
Description
PMRD a
PMRDb
33
32
O
PMD Request Data: Differential, 100k ECL, 125 Mbps serial data output signals to the PMD transmitter.
SD a
SDb
37
36
I
Signal Detect: Differential 100k ECL input signals from the PMD receiver indicating that a signal is being
received by the PMD receiver.
TEL
47
I
PMD Transmitter Enable Level: A TTL input signal to select the PMD transmitter Enable (TXE) signal
level.
TXE
46
O
PMD Transmitter Enable: A TTL output signal to enable/disable the PMD transmitter. The output level
of the TXE pin is determined by three parameters: the Transmit Enable (TE) bit in the Mode Register, the
TM2-TM0 bits in the Current Transmit State Register, and the input to the TEL pin. The following rules
summarize the output of the TXE pin:
1. If TE e 0 and TEL e GND, then TXE e VCC
2. If TE e 0 and TEL e VCC, then TXE e GND
3. If TE e 1 and OTM and TEL e GND, then TXE e VCC
4. If TE e 1 and OTM and TEL e VCC, then TXE e GND
5. If TE e 1 and not OTM and TEL e GND, then TXE e GND
6. If TE e 1 and not OTM and TEL e VCC, then TXE e VCC
89
6.0 Signal Descriptions (Continued)
PHY PORT INTERFACE
The PHY Port Interface consists of I/O signals used to connect the PLAYER a device to the Media Access Control (MAC)
sublayer or other PLAYER a device. The DP83256 Device has two PHY Port Interfaces. The AÐIndicate path from one PHY
Port Interface and the BÐRequest path from the second PHY Port Interface. Each path consists of an odd parity bit, a control
bit, and two 4-bit symbols.
Refer to section 3.3, the Configuration Switch, for more information.
Symbol
Pin Ý
I/O
Description
AIP
6
O
PHY Port A Indicate Parity: A TTL output signal representing odd parity for the 10-bit wide Port A
Indicate signals (AIP, AIC, and AIDk7:0l).
AIC
7
O
PHY Port A Indicate Control: TTL output signal indicating that the two 4-bit symbols (AIDk7:4l and
AIDk3:0l) are either control symbols (AIC e 1) or data symbols (AIC e 0).
AID7
AID6
AID5
AID4
8
9
10
13
O
PHY Port A Indicate Data: TTL output signals representing the first 4-bit data/control symbol.
AID3
AID2
AID1
AID0
14
15
16
17
O
BRP
70
I
PHY Port B Request Parity: A TTL input signal representing odd parity for the 10-bit wide Port A
Request signals (BRP, BRC, and BRDk7:0l).
BRC
69
I
PHY Port B Request Control: A TTL input signal indicating that the two 4-bit symbols
AID7 is the most significant bit and AID4 is the least significant bit of the first symbol.
PHY Port A Indicate Data: TTL output signals representing the second 4-bit data/control symbol.
AID3 is the most significant bit and AID0 is the least significant bit of the second symbol.
(BRDk7:4l and BRDk3:0l) are either control symbols (BRC e 1) or data symbols (BRC e 0).
BRD7
BRD6
BRD5
BRD4
68
67
66
63
I
BRD3
BRD2
BRD1
BRD0
62
61
60
59
I
PHY Port B Request Data: TTL input signals representing the first 4-bit data/control symbol.
BRD7 is the most significant bit and BRD4 is the least significant bit of the first symbol.
PHY Port B Request Data: TTL input signals representing the second 4-bit data/control symbol.
BRD3 is the most significant bit and BRD0 is the least significant bit of the second symbol.
90
6.0 Signal Descriptions (Continued)
CONTROL BUS INTERFACE
The Control Bus Interface consists of I/O signals used to connect the PLAYER a device to Station Management (SMT).
The Control Bus is an asynchronous interface between the PLAYER a device and a general purpose microprocessor or other
controller. It provides access to 64 8-bit internal registers.
In the PLAYER a device the Control Bus address range has been expanded by 1-bit to 6 bits of address space.
Symbol
Pin Ý
I/O
E CE
73
I
Control Enable: An active-low, TTL, input signal which enables the Control Bus port for a read or write
cycle. R/ E W, CBAk5:0l, CBP, and CBDk7:0l must be valid at the time E CE is low.
Description
R/ E W
72
I
Read/ E Write: A TTL input signal which indicates a read Control Bus cycle(R/ E W e 1), or a write
Control Bus cycle (R/ E W e 0).
E ACK
75
O
E Acknowledge: An active low, TTL, open drain output signal which indicates the completion of a read
or write cycle. During a read cycle, CBDk7:0l are valid as long as E ACK is low ( E ACK e 0). During a
write cycle, a microprocessor must hold CBDk7:0l valid until E ACK becomes low. Once E ACK is low,
it will remain low as long as E CE remains low ( E CE e 0).
E INT
74
O
E Interrupt: An active low, open drain, TTL, output signal indicating that an interrupt condition has
occurred. The Interrupt Condition Register (ICR) should be read in order to find out the source of the
interrupt. Interrupts can be masked through the use of the Interrupt Condition Mask Register (ICMR).
CBA5
CBA4
CBA3
CBA2
CBA1
CBA0
83
82
81
80
77
76
I
Control Bus Address: TTL input signals used to select the address of the register to be read or written.
CBP
96
I/O
CBA5 is the most significant bit (MSB) and CBA0 is the least significant bit (LSB) of the address signals.
Control Bus Parity: A bidirectional, TTL signal representing odd parity for the Control Bus data
(CBDk7:0l).
During a read cycle, the signal is held valid by the PLAYER a device as long as E ACK is low.
During a write cycle, the signal must be valid when E CE is low, and must be held valid until E ACK
becomes low. If incorrect parity is used during a write cycle, the PLAYER a device will inhibit the write
cycle and set the Control Bus Data Parity Error (CPE) bit in the Interrupt Condition Register (ICR).
CBD7
CBD6
CBD5
CBD4
CBD3
CBD2
CBD1
CBD0
95
94
93
92
91
90
89
86
I/O
Control Bus Data: Bidirectional, TTL signals containing the data to be read from or written to a register.
During a read cycle, the signal is held valid by the PLAYER a device as long as E ACK is low.
During a write cycle, the signal must be valid when E CE is low, and must be held valid until E ACK
becomes low.
91
6.0 Signal Descriptions (Continued)
CLOCK INTERFACE
The Clock Interface consists of 12.5 MHz and 25 MHz clocks supplied by the PLAYER a device as well as reference and
feedback inputs.
Symbol
Pin Ý
I/O
Description
LBC1
LBC2
LBC3
LBC4
LBC5
4
3
2
1
100
O
Local Byte Clock: TTL compatible, 12.5 MHz, 50% duty cycle clock outputs which are phase
locked to a crystal oscillator or reference signal. The PHÐSEL input determines whether the five
phase outputs are phase offset by 8 ns or 16 ns.
PHÐSEL
22
I
Phase Select: TTL compatible input used to select either a 8 ns or 16 ns phase offset between the 5
local byte clocks (LBC’s). The LBC’s are phase offset 8ns apart when PHÐSEL is at a logic LOW
level and 16 ns apart when at a logic HI level.
FBKÐIN
25
I
Feedback Input: TTL compatible input for use as the PLL’s phase comparator feedback input to
close the Phase Locked Loop. This input is intended to be driven from one of the Local Byte Clocks
(LBC’s) from the same PLAYER a device.
LSC
99
O
Local Symbol Clock: TTL compatible 25 MHz output for driving the MACSI or BMAC devices. This
output’s negative phase transition is aligned with the LBC1 output transitions and has a 40% HI and
60% LOW duty cycle.
CLK16
5
O
Clock 16/32: TTL compatible clock with a selectable frequency of approximately 15.625 MHz or
31.25 MHz. The frequency can be selected using the Clock Select (CLKSEL) bit of the Mode 2
Register (MODE2).
Note: No glitches appear at the output when switching frequencies.
XTALÐIN
27
I
External Crystal Oscillator Input: This input in conjunction with the XTALÐOUT output, is
designed for use of an external crystal oscillator network as the frequency reference for the clock
generation module’s internal VCO. A diagram of the required circuit, which includes only a 12.5 MHz
crystal and 2 loading capacitors, is shown in Figure 3-19 .
This input is selected when the REFÐSEL input is at a logic LOW level. When not being used, this
input should be tied to ground.
XTALÐOUT
26
O
External Crystal Oscillator Output: This output in conjunction with the XTALÐIN input, is designed
for use of an external crystal oscillator network as the frequency reference for the clock generation
module’s internal VCO. A diagram of the required circuit, which includes only a 12.5 MHz crystal and
2 loading capacitors, is shown in Figure 3-19 .
REFÐIN
24
I
Reference Input: TTL compatible input for use as the PLL’s phase comparator reference frequency.
This input is for use in dual attach station or concentrator configurations where there are multiple
PLAYER a devices at a given site requiring synchronization.
This input is selected when the REFÐSEL input is at a logic HI level.
REFÐSEL
23
I
Reference Select: TTL compatible input which selects either the crystal oscillator inputs XTALÐIN
and XTALÐOUT or the REFÐIN inputs as the reference frequency inputs for the PLL.
The crystal oscillator inputs are selected when REFÐSEL is at a logic LOW level and the REFÐIN
input is selected as the reference when REFÐSEL is at a logic HI level.
LPFLTR
30
O
Loop Filter: This is a diagnostic output that allows monitoring of the clock generation module’s filter
node. This output is disabled by default and does not need to be connected to any external device. It
can be enabled using the FLTREN bit of the Clock generation module register (CGMREG).
Note: In normal operation this pin should be disabled.
92
6.0 Signal Descriptions (Continued)
MISCELLANEOUS INTERFACE
The Miscellaneous Interface consist of a reset signal, user definable sense signals, and user definable enable signals.
Symbol
Pin Ý
I/O
E RST
Description
71
I
Reset: An active low, TTL, input signal which clears all registers. The signal must be kept asserted for a
minimum amount of time. Once the E RST signal is asserted, the PLAYER a device should be allowed
the specified amount of time to reset internal logic. Note that bit zero of the Mode Register will be set to
zero (i.e. Stop Mode). See section 4.2, Stop Mode of Operation for more information
SP0
40
I
User Definable Sense Pin 0: A TTL input signal from a user defined source. Sense Bit 0 (SB0) of the
User Definable Register (UDR) will be set to one if the signal is asserted for a minimum of 160 ns. Once
the asserted signal is latched, Sense Bit 0 can only be cleared through the Control Bus Interface, even if
the signal is deasserted. This ensures that the Control Bus Interface will record the source of events
which can cause interrupts.
SP1
42
I
User Definable Sense Pin 1: A TTL input signal from a user defined source. Sense Bit 1 (SB1) of the
User Definable Register (UDR) will be set to one if the signal is asserted for a minimum of 160 ns. Once
the asserted signal is latched, Sense Bit 1 can only be cleared through the Control Bus Interface, even if
the signal is deasserted. This ensures that the Control Bus Interface will record the source of events
which can cause interrupts.
EP0
41
O
User Definable Enable Pin 0: A TTL output signal allowing control of external logic through the Control
Bus Interface. EP0 is asserted/deasserted through Enable Bit 0 (EB0) of the User Definable Register
(UDR). When Enable Bit 0 is set to zero, EP0 is deasserted. When Enable Bit 0 is set to one, EP0 is
asserted.
EP1
43
O
User Definable Enable Pin 1: A TTL output signal allowing control of external logic through the Control
Bus Interface. EP1 is asserted/deasserted through Enable Bit 1 (EB1) of the User Definable Register
(UDR). When Enable Bit 1 is set to zero, EP1 is deasserted. When Enable Bit 1 is set to one, EP1 is
asserted.
93
6.0 Signal Descriptions (Continued)
POWER AND GROUND
All power pins should be connected to a single a 5V power supply using the recommended filtering. All ground pins should be
connected to a common 0V ground supply. Bypassing and filtering requirements are given in a separate User Information
Document.
Symbol
Pin Ý
VCCÐANALOG
20
I/O
Power: Positive 5V power supply for the PLAYER a device’s CGM VCO.
Description
GNDÐANALOG
21
Ground: Power supply return for the PLAYER a device’s CGM VCO.
VCCÐCORE
88
Power: Positive 5V power supply for the core PLAYER section logic gates.
GNDÐCORE
87
Ground: Power supply return for the core PLAYER section logic gates.
VCCÐECL
31,
34,
44,
56
Power: Positive 5V power supply for the PLAYER a device’s ECL logic gates.
GNDÐECL
35,
45,
55
Ground: Power supply return for the PLAYER a device’s ECL logic gates.
VCCÐESD
28
Power: Positive 5V power supply for the PLAYER a device’s ESD protection circuitry.
GNDÐESD
29
Ground: Power supply return for the PLAYER a device’s ESD protection circuitry.
VCCÐIO
11,
65,
79,
98
Power: Positive 5V power supply for the input/output buffers.
GNDÐIO
12,
64,
78,
97
Ground: Power supply return for the input/output buffers.
SPECIAL CONNECT PINS
These are pins that have special connection requirements.
No Connect (N/C) pins should not be connected to anything. This means not to power, not to ground, and not to each other.
ReservedÐ0 (RESÐ0) pins must be connected to ground. These pins are not used to supply device power so they do not need
to be filtered or bypassed.
ReservedÐ1 (RESÐ1) pins must be connected to power. These pins are not used to supply device power so they do not need
to be filtered or bypassed.
Symbol
Pin Ý
N/C
49, 54
I/O
No Connect: Pins should not be connected to anything. This means not to power, not to ground, and
not to each other.
Description
RESÐ0
18, 19,
48, 50,
51, 52,
53, 57,
58, 84
Reserved 0: Pins must be connected to ground. These pins are not used to supply device power so
they do not need to be filtered or bypassed.
RESÐ1
85
Reserved 1: Pins must be connected to power. These pins are not used to supply device power so they
do not need to be filtered or bypassed.
94
6.0 Signal Descriptions (Continued)
6.2 DP83256VF-AP SIGNAL DESCRIPTIONS
The pin descriptions for the DP83256VF-AP are divided into five functional interfaces; PMD Interface, PHY Port Interface,
Control Bus Interface, Clock Interface, and Miscellaneous Interface.
For a Pinout Summary List, refer to Table 8-2 and Figure 8-2 , DP83256VF-AP 100-Pin JEDEC Metric PQFP Pinout.
PMD INTERFACE
The PMD Interface consists of I/O signals used to connect the PLAYER a device to the Physical Medium Dependant (PMD)
sublayer.
The DP83256VF-AP PLAYER a device actually has two PMD interfaces. The Primary PMD Interface and the Alternate PMD
Interface.
The Primary PMD Interface should be used for all PMD implementations that do not require an external scrambler/descrambler
function, clock recovery function, or clock generation function, such as a Fiber Optic or Shielded Twisted Pair (SDDI) PMD. The
second, Alternate PMD Interface can be used to support Unshielded Twisted Pair (UTP) PMDs that require external scrambling,
with no external clock recovery or clock generation functions required.
Section 3.8 describes how the PLAYER a can be connected to the PMD and how the Alternate PMD can be enabled.
Note that when the Alternate PMD Interface is not being used, the pins that make up the interface must be connected in the
specific way described in the following Alternate PMD Interface table.
Primary PMD Interface
Symbol
Pin Ý
I/O
PMID a
PMIDb
42
41
I
PMD Indicate Data: Differential, 100k ECL, 125 Mbps serial data input signals from the PMD Receiver
into the Clock Recovery Module (CRM) of the PLAYER a .
Description
PMRD a
PMRDb
34
33
O
PMD Request Data: Differential, 100k ECL, 125 Mbps serial data output signals to the PMD transmitter.
SD a
SDb
40
39
I
Signal Detect: Differential 100k ECL input signals from the PMD receiver indicating that a signal is being
received by the PMD receiver.
95
6.0 Signal Descriptions (Continued)
Alternate PMD Interface
Pin Ý
I/O
PMID a
PMIDb
Symbol
42
41
I
PMD Indicate Data: Differential, 100k ECL, 125 Mbps serial data input signals from the PMD
Receiver into the Clock Recovery Module (CRM) of the PLAYER a .
Description
RXCÐOUT a
RXCÐOUTb
36
35
O
Recovered Clock Out: 125 MHz clock recovered by the Clock Recovery Module (CRM) from the
PMID data input.
These signals are only active when the Alternate PMD Enable (APMDEN) bit of the Alternate PMD
Register (APMDREG) is set to a 1 and are off by default after Reset.
When these two pins are not used they should be left Not Connected (N/C).
RXDÐOUT a
RXDÐOUTb
52
51
O
Recovered Data Out: 125 Mbps data recovered by the Clock Recovery Module (CRM) from the
PMID data input.
These signals are only active when the Alternate PMD Enable (APMDEN) bit of the Alternate PMD
Register (APMDREG) is set to a 1 and are off by default after Reset.
When these two pins are not used they should be left Not Connected (N/C).
RXCÐIN a
RXCÐINb
48
47
I
Receive Clock In: Clock inputs to the Player section of the PLAYER a . These inputs must be
synchronized with the RXDÐIN inputs.
These signals are only active when the Alternate PMD Enable (APMDEN) bit of the Alternate PMD
Register (APMDREG) is set to a 1 and are off by default after Reset.
When these two pins are not used, pin 76 should be left Not Connected (N/C) and pin 75 should be
connected directly to ground (ReservedÐ0).
RXDÐIN a
RXDÐINb
50
49
I
Receive Data In: Data inputs to the Player section of the PLAYER a . These inputs must be
synchronized with the RXCÐIN inputs.
These signals are only active when the Alternate PMD Enable (APMDEN) bit of the Alternate PMD
Register (APMDREG) is set to a 1 and are off by default after Reset.
When these two pins are not used, pin 78 should be left Not Connected (N/C) and pin 77 should be
connected directly to ground (ReservedÐ0).
PMRD a
PMRDb
34
33
O
PMD Request Data: Differential, 100k ECL, 125 Mbps serial data output signals to the PMD
transmitter.
TXC a
TXCb
31
30
O
Transmit Clock: 125 MHz, 100k ECL compatible differential outputs synchronized to the outgoing
PMRD data.
These signals can be enabled using the Transmit Clock Enable (TXCE) bit in the Clock Generation
Module Register (CGMREG).
When these two pins are not used they should be left Not Connected (N/C).
SD a
SDb
40
39
I
Signal Detect: Differential, 100k ECL, input signals from the PMD receiver indicating that a signal
is being received by the PMD receiver.
96
6.0 Signal Descriptions (Continued)
PHY PORT INTERFACE
The PHY Port Interface consists of I/O signals used to connect the PLAYER a device to the Media Access Control (MAC)
sublayer or other PLAYER a device. The DP83256 Device has two PHY Port Interfaces. The AÐIndicate path from one PHY
Port Interface and the BÐRequest path from the second PHY Port Interface. Each path consists of an odd parity bit, a control
bit, and two 4-bit symbols.
Refer to section 3.3, the Configuration Switch, for more information.
Symbol
Pin Ý
I/O
Description
AIP
6
O
PHY Port A Indicate Parity: A TTL output signal representing odd parity for the 10-bit wide Port A
Indicate signals (AIP, AIC, and AIDk7:0l).
AIC
7
O
PHY Port A Indicate Control: TTL output signal indicating that the two 4-bit symbols (AIDk7:4l and
AIDk3:0l) are either control symbols (AIC e 1) or data symbols (AIC e 0).
AID7
AID6
AID5
AID4
8
9
10
13
O
PHY Port A Indicate Data: TTL output signals representing the first 4-bit data/control symbol.
AID3
AID2
AID1
AID0
14
15
16
17
O
BRP
70
I
PHY Port B Request Parity: A TTL input signal representing odd parity for the 10-bit wide Port A
Request signals (BRP, BRC, and BRDk7:0l).
BRC
69
I
PHY Port B Request Control: A TTL input signal indicating that the two 4-bit symbols (BRDk7:4l and
BRDk3:0l) are either control symbols (BRC e 1) or data symbols (BRC e 0).
BRD7
BRD6
BRD5
BRD4
68
67
66
63
I
PHY Port B Request Data: TTL input signals representing the first 4-bit data/control symbol.
BRD3
BRD2
BRD1
BRD0
62
61
60
59
I
AID7 is the most significant bit and AID4 is the least significant bit of the first symbol.
PHY Port A Indicate Data: TTL output signals representing the second 4-bit data/control symbol.
AID3 is the most significant bit and AID0 is the least significant bit of the second symbol.
BRD7 is the most significant bit and BRD4 is the least significant bit of the first symbol.
PHY Port B Request Data: TTL input signals representing the second 4-bit data/control symbol.
BRD3 is the most significant bit and BRD0 is the least significant bit of the second symbol.
97
6.0 Signal Descriptions (Continued)
CONTROL BUS INTERFACE
The Control Bus Interface consists of I/O signals used to connect the PLAYER a device to Station Management (SMT).
The Control Bus is an asynchronous interface between the PLAYER a device and a general purpose microprocessor or other
controller. It provides access to 64 8-bit internal registers.
In the PLAYER a device the Control Bus address range has been expanded by 1-bit to 6 bits of address space.
Symbol
Pin Ý
I/O
E CE
73
I
Control Enable: An active-low, TTL, input signal which enables the Control Bus port for a read or write
cycle. R/ E W, CBAk5:0l, CBP, and CBDk7:0l must be valid at the time E CE is low.
Description
R/ E W
72
I
Read/ E Write: A TTL input signal which indicates a read Control Bus cycle (R/ E W e 1), or a write
Control Bus cycle (R/ E W e 0).
E ACK
75
O
E Acknowledge: An active low, TTL, open drain output signal which indicates the completion of a read
or write cycle. During a read cycle, CBDk7:0l are valid as long as E ACK is low ( E ACK e 0). During a
write cycle, a microprocessor must hold CBDk7:0l valid until E ACK becomes low. Once E ACK is low,
it will remain low as long as E CE remains low ( E CE e 0).
E INT
74
O
E Interrupt: An active low, open drain, TTL, output signal indicating that an interrupt condition has
occurred. The Interrupt Condition Register (ICR) should be read in order to find out the source of the
interrupt. Interrupts can be masked through the use of the Interrupt Condition Mask Register (ICMR).
CBA5
CBA4
CBA3
CBA2
CBA1
CBA0
83
82
81
80
77
76
I
Control Bus Address: TTL input signals used to select the address of the register to be read or written.
CBP
96
I/O
CBA5 is the most significant bit (MSB) and CBA0 is the least significant bit (LSB) of the address signals.
Control Bus Parity: A bidirectional, TTL signal representing odd parity for the Control Bus data
(CBDk7:0l).
During a read cycle, the signal is held valid by the PLAYER a device as long as E ACK is low.
During a write cycle, the signal must be valid when E CE is low, and must be held valid until E ACK
becomes low. If incorrect parity is used during a write cycle, the PLAYER a device will inhibit the write
cycle and set the Control Bus Data Parity Error (CPE) bit in the Interrupt Condition Register (ICR).
CBD7
CBD6
CBD5
CBD4
CBD3
CBD2
CBD1
CBD0
95
94
93
92
91
90
89
86
I/O
Control Bus Data: Bidirectional, TTL signals containing the data to be read from or written to a register.
During a read cycle, the signal is held valid by the PLAYER a device as long as E ACK is low.
During a write cycle, the signal must be valid when E CE is low, and must be held valid until E ACK
becomes low.
98
6.0 Signal Descriptions (Continued)
CLOCK INTERFACE
The Clock Interface consists of 12.5 MHz and 25 MHz clocks supplied by the PLAYER a device as well as reference and
feedback inputs.
Symbol
Pin Ý
I/O
Description
LBC1
LBC2
LBC3
LBC4
LBC5
4
3
2
1
100
O
Local Byte Clock: TTL compatible, 12.5 MHz, 50% duty cycle clock outputs which are phase
locked to a crystal oscillator or reference signal. The PHÐSEL input determines whether the five
phase outputs are phase offset by 8 ns or 16 ns.
PHÐSEL
22
I
Phase Select: TTL compatible input used to select either a 8 ns or 16 ns phase offset between the 5
local byte clocks (LBC’s). The LBC’s are phase offset 8 ns apart when PHÐSEL is at a logic LOW
level and 16 ns apart when at a logic HI level.
FBKÐIN
25
I
Feedback Input: TTL compatible input for use as the PLL’s phase comparator feedback input to
close the Phase Locked Loop. This input is intended to be driven from one of the Local Byte Clocks
(LBC’s) from the same PLAYER a device.
LSC
99
O
Local Symbol Clock: TTL compatible 25 MHz output for driving the MACSI or BMAC devices. This
output’s negative phase transition is aligned with the LBC1 output transitions and has a 40% HI and
60% LOW duty cycle.
CLK16
5
O
Clock 16/32: TTL compatible clock with a selectable frequency of approximately 15.625 MHz or
31.25 MHz. The frequency can be selected using the Clock Select (CLKSEL) bit of the Mode 2
Register (MODE2).
Note: No glitches appear at the output when switching frequencies.
XTALÐIN
27
I
External Crystal Oscillator Input: This input in conjunction with the XTALÐOUT output, is
designed for use of an external crystal oscillator network as the frequency reference for the clock
generation module’s internal VCO. A diagram of the required circuit, which includes only a 12.5 MHz
crystal and 2 loading capacitors, is shown in Figure 3-19 .
This input is selected when the REFÐSEL input is at a logic LOW level. When not being used, this
input should be tied to ground.
XTALÐOUT
26
O
External Crystal Oscillator Output: This output in conjunction with the XTALÐIN input, is designed
for use of an external crystal oscillator network as the frequency reference for the clock generation
module’s internal VCO. A diagram of the required circuit, which includes only a 12.5 MHz crystal and
2 loading capacitors, is shown in Figure 3-19 .
REFÐIN
24
I
Reference Input: TTL compatible input for use as the PLL’s phase comparator reference frequency.
This input is for use in dual attach station or concentrator configurations where there are multiple
PLAYER a devices at a given site requiring synchronization.
This input is selected when the REFÐSEL input is at a logic HI level.
REFÐSEL
23
I
Reference Select: TTL compatible input which selects either the crystal oscillator inputs XTALÐIN
and XTALÐOUT or the REFÐIN inputs as the reference frequency inputs for the PLL.
The crystal oscillator inputs are selected when REFÐSEL is at a logic LOW level and the REFÐIN
input is selected as the reference when REFÐSEL is at a logic HI level.
99
6.0 Signal Descriptions (Continued)
MISCELLANEOUS INTERFACE
The Miscellaneous Interface consist of a reset signal and user definable enable signals.
Symbol
Pin Ý
I/O
E RST
Description
71
I
Reset: An active low, TTL, input signal which clears all registers. The signal must be kept asserted for a
minimum amount of time. Once the E RST signal is asserted, the PLAYER a device should be allowed
the specified amount of time to reset internal logic. Note that bit zero of the Mode Register will be set to
zero (i.e. Stop Mode). See section 4.2, Stop Mode of Operation for more information
EP0
41
O
User Definable Enable Pin 0: A TTL output signal allowing control of external logic through the Control
Bus Interface. EP0 is asserted/deasserted through Enable Bit 0 (EB0) of the User Definable Register
(UDR). When Enable Bit 0 is set to zero, EP0 is deasserted. When Enable Bit 0 is set to one, EP0 is
asserted.
EP1
43
O
User Definable Enable Pin 1: A TTL output signal allowing control of external logic through the Control
Bus Interface. EP1 is asserted/deasserted through Enable Bit 1 (EB1) of the User Definable Register
(UDR). When Enable Bit 1 is set to zero, EP1 is deasserted. When Enable Bit 1 is set to one, EP1 is
asserted.
100
6.0 Signal Descriptions (Continued)
POWER AND GROUND
All power pins should be connected to a single a 5V power supply using the recommended filtering. All ground pins should be
connected to a common 0V ground supply. Bypassing and filtering requirements are given in a separate User Information
Document.
Symbol
Pin Ý
VCCÐANALOG
20
I/O
Power: Positive 5V power supply for the Clock Generation Module VCO.
Description
GNDÐANALOG
21
Ground: Power supply return for the Clock Generation Module VCO.
VCCÐCORE
88
Power: Positive 5V power supply for the core PLAYER section logic gates.
GNDÐCORE
87
Ground: Power supply return for the core PLAYER section logic gates.
VCCÐECL
32,
37,
45,
56
Power: Positive 5V power supply for the PLAYER a device’s ECL logic gates.
GNDÐECL
38,
46,
55
Ground: Power supply return for the PLAYER a device’s ECL logic gates.
VCCÐESD
28
Power: Positive 5V power supply for the PLAYER a device’s ESD protection circuitry.
GNDÐESD
29
Ground: Power supply return for the PLAYER a device’s ESD protection circuitry.
VCCÐIO
11,
65,
79,
98
Power: Positive 5V power supply for the input/output buffers.
GNDÐIO
12,
64,
78,
97
Ground: Power supply return for the input/output buffers.
SPECIAL CONNECT PINS
These are pins that have special connection requirements.
No Connect (N/C) pins should not be connected to anything. This means not to power, not to ground, and not to each other.
ReservedÐ0 (RESÐ0) pins must be connected to ground. These pins are not used to supply device power so they do not need
to be filtered or bypassed.
ReservedÐ1 (RESÐ1) pins must be connected to power. These pins are not used to supply device power so they do not need
to be filtered or bypassed.
Symbol
Pin Ý
N/C
49, 53,
54
I/O
No Connect: Pins should not be connected to anything. This means not to power, not to ground, and
not to each other.
Description
RESÐ0
18, 19,
48, 50,
51, 52,
57, 58,
84
Reserved 0: Pins must be connected to ground. These pins are not used to supply device power so
they do not need to be filtered or bypassed.
RESÐ1
85
Reserved 1: Pins must be connected to power. These pins are not used to supply device power so they
do not need to be filtered or bypassed.
101
6.0 Signal Descriptions (Continued)
6.3 DP83257VF SIGNAL DESCRIPTIONS
The pin descriptions for the DP83257VF are divided into five functional interfaces; PMD Interface, PHY Port Interface, Control
Bus Interface, Clock Interface, and Miscellaneous Interface.
For a Pinout Summary List, refer to Table 8-3 and Figure 8-3 , DP83257VF 160-Pin JEDEC Metric PQFP Pinout.
PMD INTERFACE
The PMD Interface consists of I/O signals used to connect the PLAYER a device to the Physical Medium Dependant (PMD)
sublayer.
The DP83257 PLAYER a device actually has two PMD interfaces. The Primary PMD Interface and the Alternate PMD Interface.
The Primary PMD Interface should be used for all PMD implementations that do not require an external scrambler/descrambler
function, clock recovery function, or clock generation function, such as a Fiber Optic or Shielded Twisted Pair (SDDI) PMD. The
second, Alternate PMD Interface can be used to support Unshielded Twisted Pair (UTP) PMDs that require external scrambling,
with no external clock recovery or clock generation functions required.
Section 3.8 describes how the PLAYER a can be connected to the PMD and how the Alternate PMD can be enabled.
Note that when the Alternate PMD Interface is not being used, the pins that make up the interface must be connected in the
specific way described in the following Alternate PMD Interface table.
Primary PMD Interface
Symbol
Pin Ý
I/O
PMID a
PMIDb
62
61
I
PMD Indicate Data: Differential, 100k ECL, 125 Mbps serial data input signals from the PMD Receiver
into the Clock Recovery Module (CRM) of the PLAYER a .
Description
PMRD a
PMRDb
54
53
O
PMD Request Data: Differential, 100k ECL, 125 Mbps serial data output signals to the PMD transmitter.
SD a
SDb
60
59
I
Signal Detect: Differential 100k ECL input signals from the PMD receiver indicating that a signal is being
received by the PMD receiver.
TEL
74
I
PMD Transmitter Enable Level: A TTL input signal to select the PMD transmitter Enable (TXE) signal
level.
TXE
73
O
PMD Transmitter Enable: A TTL output signal to enable/disable the PMD transmitter. The output level
of the TXE pin is determined by three parameters: the Transmit Enable (TE) bit in the Mode Register, the
TM2–TM0 bits in the Current Transmit State Register, and the input to the TEL pin. The following rules
summarize the output of the TXE pin:
1. If TE e 0 and TEL e GND, then TXE e VCC
2. If TE e 0 and TEL e VCC, then TXE e GND
3. If TE e 1 and OTM and TEL e GND, then TXE e VCC
4. If TE e 1 and OTM and TEL e VCC, then TXE e GND
5. If TE e 1 and not OTM and TEL e GND, then TXE e GND
6. If TE e 1 and not OTM and TEL e VCC, then TXE e VCC
102
6.0 Signal Descriptions (Continued)
Alternate PMD Interface
Pin Ý
I/O
PMID a
PMIDb
Symbol
62
61
I
PMD Indicate Data: Differential, 100k ECL, 125 Mbps serial data input signals from the PMD
Receiver into the Clock Recovery Module (CRM) of the PLAYER a .
Description
RXCÐOUT a
RXCÐOUTb
56
55
O
Recovered Clock Out: 125 MHz clock recovered by the Clock Recovery Module (CRM) from the
PMID data input.
These signals are only active when the Alternate PMD Enable (APMDEN) bit of the Alternate PMD
Register (APMDREG) is set to a 1 and are off by default after Reset.
When these two pins are not used they should be left Not Connected (N/C).
RXDÐOUT a
RXDÐOUTb
83
82
O
Recovered Data Out: 125 Mbps data recovered by the Clock Recovery Module (CRM) from the
PMID data input.
These signals are only active when the Alternate PMD Enable (APMDEN) bit of the Alternate PMD
Register (APMDREG) is set to a 1 and are off by default after Reset.
When these two pins are not used they should be left Not Connected (N/C).
RXCÐIN a
RXCÐINb
76
75
I
Receive Clock In: Clock inputs to the Player section of the PLAYER a . These inputs must be
synchronized with the RXDÐIN inputs.
These signals are only active when the Alternate PMD Enable (APMDEN) bit of the Alternate PMD
Register (APMDREG) is set to a 1 and are off by default after Reset.
When these two pins are not used, pin 76 should be left Not Connected (N/C) and pin 75 should be
connected directly to ground (ReservedÐ0).
RXDÐIN a
RXDÐINb
78
77
I
Receive Data In: Data inputs to the Player section of the PLAYER a . These inputs must be
synchronized with the RXCÐIN inputs.
These signals are only active when the Alternate PMD Enable (APMDEN) bit of the Alternate PMD
Register (APMDREG) is set to a 1 and are off by default after Reset.
When these two pins are not used, pin 78 should be left Not Connected (N/C) and pin 77 should be
connected directly to ground (ReservedÐ0).
PMRD a
PMRDb
54
53
O
PMD Request Data: Differential, 100k ECL, 125 Mbps serial data output signals to the PMD
transmitter.
TXC a
TXCb
51
50
O
Transmit Clock: 125 MHz, 100k ECL compatible differential outputs synchronized to the outgoing
PMRD data.
These signals can be enabled using the Transmit Clock Enable (TXCE) bit in the Clock Generation
Module Register (CGMREG).
When these two pins are not used they should be left Not Connected (N/C).
SD a
SDb
60
59
I
Signal Detect: Differential, 100k ECL, input signals from the PMD receiver indicating that a signal
is being received by the PMD receiver.
TEL
74
I
PMD Transmitter Enable Level: A TTL input signal to select the PMD transmitter Enable (TXE)
signal level.
TXE
73
O
PMD Transmitter Enable: A TTL output signal to enable/disable the PMD transmitter. The output
level of the TXE pin is determined by three parameters: the Transmit Enable (TE) bit in the Mode
Register, the TM2–TM0 bits in the Current Transmit State Register, and the input to the TEL pin.
The following rules summarize the output of the TXE pin:
1. If TE e 0 and TEL e GND, then TXE e VCC
2. If TE e 0 and TEL e VCC, then TXE e GND
3. If TE e 1 and OTM and TEL e GND, then TXE e VCC
4. If TE e 1 and OTM and TEL e VCC, then TXE e GND
5. If TE e 1 and not OTM and TEL e GND, then TXE e GND
6. If TE e 1 and not OTM and TEL e VCC, then TXE e VCC
103
6.0 Signal Descriptions (Continued)
PHY PORT INTERFACE
The PHY Port Interface consists of I/O signals used to connect the PLAYER a device to the Media Access Control (MAC)
sublayer or other PLAYER a device. The DP83257 Device has two PHY Port Interfaces. The AÐRequest and AÐIndicate paths
from one PHY Port Interface and the BÐRequest and BÐIndicate paths from the second PHY Port Interface. Each path
consists of an odd parity bit, a control bit, and two 4-bit symbols.
Refer to section 3.3, the Configuration Switch, for more information.
Symbol
Pin Ý
I/O
Description
AIP
6
O
PHY Port A Indicate Parity: A TTL output signal representing odd parity for the 10-bit wide Port A
Indicate signals (AIP, AIC, and AIDk7:0l).
AIC
8
O
PHY Port A Indicate Control: A TTL output signal indicating that the two 4-bit symbols (AIDk7:4l and
AIDk3:0l) are either control symbols (AIC e 1) or data symbols (AIC e 0).
AID7
AID6
AID5
AID4
10
12
14
18
O
PHY Port A Indicate Data: TTL output signals representing the first 4-bit data/control symbol.
AID3
AID2
AID1
AID0
20
22
24
26
O
ARP
7
I
PHY Port A Request Parity: A TTL input signal representing odd parity for the 10-bit wide Port A
Request signals (ARP, ARC, and ARDk7:0l).
ARC
9
I
PHY Port A Request Control: A TTL input signal indicating that the two 4-bit symbols
(ARDk7:4l and ARDk3:0l) are either control symbols (ARC e 1) or data symbols (ARC e 0).
ARD7
ARD6
ARD5
ARD4
11
13
15
19
I
PHY Port A Request Data: TTL input signals representing the first 4-bit data/control symbol.
ARD3
ARD2
ARD1
ARD0
21
23
25
27
I
BIP
114
O
PHY Port B Indicate Parity: A TTL output signal representing odd parity for the 10-bit wide Port A
Indicate signals (BIP, BIC, and BIDk7:0l).
BIC
112
O
PHY Port B Indicate Control: A TTL output signal indicating that the two 4-bit symbols (BIDk7:4l and
BIDk3:0l) are either control symbols (BIC e 1) or data symbols (BIC e 0).
BID7
BID6
BID5
BID4
110
108
106
102
O
PHY Port B Indicate Data: TTL output signals representing the first 4-bit data/control symbol.
BID3
BID2
BID1
BID0
100
98
96
94
O
BRP
115
I
PHY Port B Request Parity: A TTL input signal representing odd parity for the 10-bit wide Port A
Request signals (BRP, BRC, and BRDk7:0l).
BRC
113
I
PHY Port B Request Control: A TTL input signal indicating that the two 4-bit symbols
(BRDk7:4l and BRDk3:0l) are either control symbols (BRC e 1) or data symbols (BRC e 0).
AID7 is the most significant bit and AID4 is the least significant bit of the first symbol.
PHY Port A Indicate Data: TTL output signals representing the second 4-bit data/control symbol.
AID3 is the most significant bit and AID0 is the least significant bit of the second symbol.
ARD7 is the most significant bit and ARD4 is the least significant bit of the first symbol.
PHY Port A Request Data: TTL input signals representing the second 4-bit data/control symbol.
ARD3 is the most significant bit and ARD0 is the least significant bit of the second symbol.
BID7 is the most significant bit and BID4 is the least significant bit of the first symbol.
PHY Port B Indicate Data: TTL output signals representing the second 4-bit data/control symbol.
BID3 is the most significant bit and BID0 is the least significant bit of the second symbol.
104
6.0 Signal Descriptions (Continued)
Pin Ý
I/O
BRD7
BRD6
BRD5
BRD4
Symbol
111
109
107
103
I
BRD3
BRD2
BRD1
BRD0
101
99
97
95
I
Description
PHY Port B Request Data: TTL input signals representing the first 4-bit data/control symbol.
BRD7 is the most significant bit and BRD4 is the least significant bit of the first symbol.
PHY Port B Request Data: TTL input signals representing the second 4-bit data/control symbol.
BRD3 is the most significant bit and BRD0 is the least significant bit of the second symbol.
105
6.0 Signal Descriptions (Continued)
CONTROL BUS INTERFACE
The Control Bus Interface consists of I/O signals used to connect the PLAYER a device to Station Management (SMT).
The Control Bus is an asynchronous interface between the PLAYER a device and a general purpose microprocessor or other
controller. It provides access to 64 8-bit internal registers.
In the PLAYER a device the Control Bus address range has been expanded by 1-bit to 6 bits of address space.
Symbol
Pin Ý
I/O
E CE
118
I
Control Enable: An active-low, TTL, input signal which enables the Control Bus port for a read or write
cycle. R/ E W, CBAk5:0l, CBP, and CBDk7:0l must be valid at the time E CE is low.
Description
R/ E W
117
I
Read/ E Write: A TTL input signal which indicates a read Control Bus cycle (R/ E W e 1), or a write
Control Bus cycle (R/ E W e 0).
E ACK
120
O
E Acknowledge: An active low, TTL, open drain output signal which indicates the completion of a read
or write cycle. During a read cycle, CBDk7:0l are valid as long as E ACK is low ( E ACK e 0). During a
write cycle, a microprocessor must hold CBDk7:0l valid until E ACK becomes low. Once E ACK is low,
it will remain low as long as E CE remains low ( E CE e 0).
E INT
119
O
E Interrupt: An active low, open drain, TTL, output signal indicating that an interrupt condition has
occurred. The Interrupt Condition Register (ICR) should be read in order to find out the source of the
interrupt. Interrupts can be masked through the use of the Interrupt Condition Mask Register (ICMR).
CBA5
CBA4
CBA3
CBA2
CBA1
CBA0
135
134
133
132
129
128
I
Control Bus Address: TTL input signals used to select the address of the register to be read or written.
CBP
148
I/O
CBA5 is the most significant bit (MSB) and CBA0 is the least significant bit (LSB) of the address signals.
Control Bus Parity: A bidirectional, TTL signal representing odd parity for the Control Bus data
(CBDl7:0l).
During a read cycle, the signal is held valid by the PLAYER a device as long as E ACK is low.
During a write cycle, the signal must be valid when E CE is low, and must be held valid until E ACK
becomes low. If incorrect parity is used during a write cycle, the PLAYER a device will inhibit the write
cycle and set the Control Bus Data Parity Error (CPE) bit in the Interrupt Condition Register (ICR).
CBD7
CBD6
CBD5
CBD4
CBD3
CBD2
CBD1
CBD0
147
146
145
144
143
142
141
138
I/O
Control Bus Data: Bidirectional, TTL signals containing the data to be read from or written to a register.
During a read cycle, the signal is held valid by the PLAYER a device as long as E ACK is low.
During a write cycle, the signal must be valid when E CE is low, and must be held valid until E ACK
becomes low.
106
6.0 Signal Descriptions (Continued)
CLOCK INTERFACE
The Clock Interface consists of 12.5 MHz and 25 MHz clocks supplied by the PLAYER a device as well as reference and
feedback inputs.
Symbol
Pin Ý
I/O
LBC1
LBC2
LBC3
LBC4
LBC5
4
3
2
1
160
O
Local Byte Clock: TTL compatible, 12.5 MHz, 50% duty cycle clock outputs which are phase
locked to a crystal oscillator or reference signal. The PHÐSEL input determines whether the five
phase outputs are phase offset by 8 ns or 16 ns.
PHÐSEL
34
I
Phase Select: TTL compatible input used to select either a 8 ns or 16 ns phase offset between the 5
local byte clocks (LBC’s). The LBC’s are phase offset 8 ns apart when PHÐSEL is at a logic LOW
level and 16 ns apart when at a logic HI level.
FBKÐIN
37
I
Feedback Input: TTL compatible input for use as the PLL’s phase comparator feedback input to
close the Phase Locked Loop. This input is intended to be driven from one of the Local Byte Clocks
(LBC’s) from the same PLAYER a device.
LSC
159
O
Local Symbol Clock: TTL compatible 25 MHz output for driving the MACSI or BMAC devices. This
output’s negative phase transition is aligned with the LBC1 output transitions and has a 40% HI and
60% LOW duty cycle.
5
O
Clock 16/32: TTL compatible clock with a selectable frequency of approximately 15.625 MHz or
31.25 MHz. The frequency can be selected using the Clock Select (CLKSEL) bit of the Mode 2
Register (MODE2).
CLK16
Description
Note: No glitches appear at the output when switching frequencies.
XTALÐIN
46
I
External Crystal Oscillator Input: This input in conjunction with the XTALÐOUT output, is
designed for use of an external crystal oscillator network as the frequency reference for the clock
generation module’s internal VCO. A diagram of the required circuit, which includes only a 12.5 MHz
crystal and 2 loading capacitors, is shown in Figure 3-19 .
This input is selected when the REFÐSEL input is at a logic LOW level. When not being used, this
input should be tied to ground.
XTALÐOUT
45
O
External Crystal Oscillator Output: This output in conjunction with the XTALÐIN input, is designed
for use of an external crystal oscillator network as the frequency reference for the clock generation
module’s internal VCO. A diagram of the required circuit, which includes only a 12.5 MHz crystal and
2 loading capacitors, is shown in Figure 3-19 .
REFÐIN
36
I
Reference Input: TTL compatible input for use as the PLL’s phase comparator reference frequency.
This input is for use in dual attach station or concentrator configurations where there are multiple
PLAYER a devices at a given site requiring synchronization.
REFÐSEL
35
I
This input is selected when the REFÐSEL input is at a logic HI level.
Reference Select: TTL compatible input which selects either the crystal oscillator inputs XTALÐIN
and XTALÐOUT or the REFÐIN inputs as the reference frequency inputs for the PLL.
The crystal oscillator inputs are selected when REFÐSEL is at a logic LOW level and the REFÐIN
input is selected as the reference when REFÐSEL is at a logic HI level.
LPFLTR
49
O
Loop Filter: This is a diagnostic output that allows monitoring of the clock generation module’s filter
node. This output is disabled by default and does not need to be connected to any external device. It
can be enabled using the FLTREN bit of the Clock generation module register (CGMREG).
Note: In normal operation this pin should be disabled.
107
6.0 Signal Descriptions (Continued)
MISCELLANEOUS INTERFACE
The Miscellaneous Interface consist of a reset signal, user definable sense signals, and user definable enable signals.
Symbol
Pin Ý
I/O
E RST
Description
116
I
Reset: An active low, TTL, input signal which clears all registers. The signal must be kept asserted for a
minimum amount of time. Once the E RST signal is asserted, the PLAYER a device should be allowed
the specified amount of time to reset internal logic. Note that bit zero of the Mode Register will be set to
zero (i.e. Stop Mode). See section 4.2, Stop Mode of Operation for more information
SP0
63
I
User Definable Sense Pin 0: A TTL input signal from a user defined source. Sense Bit 0 (SB0) of the
User Definable Register (UDR) will be set to one if the signal is asserted for a minimum of 160 ns. Once
the asserted signal is latched, Sense Bit 0 can only be cleared through the Control Bus Interface, even if
the signal is deasserted. This ensures that the Control Bus Interface will record the source of events
which can cause interrupts.
SP1
65
I
User Definable Sense Pin 1: A TTL input signal from a user defined source. Sense Bit 1 (SB1) of the
User Definable Register (UDR) will be set to one if the signal is asserted for a minimum of 160 ns. Once
the asserted signal is latched, Sense Bit 1 can only be cleared through the Control Bus Interface, even if
the signal is deasserted. This ensures that the Control Bus Interface will record the source of events
which can cause interrupts.
SP2
67
I
User Definable Sense Pin 2: A TTL input signal from a user defined source. Sense Bit 2 (SB2) of the
User Definable Register (UDR) will be set to one if the signal is asserted for a minimum of 160 ns. Once
the asserted signal is latched, Sense Bit 2 can only be cleared through the Control Bus Interface, even if
the signal is deasserted. This ensures that the Control Bus Interface will record the source of events
which can cause interrupts.
EP0
64
O
User Definable Enable Pin 0: A TTL output signal allowing control of external logic through the Control
Bus Interface. EP0 is asserted/deasserted through Enable Bit 0 (EB0) of the User Definable Register
(UDR). When Enable Bit 0 is set to zero, EP0 is deasserted. When Enable Bit 0 is set to one, EP0 is
asserted.
EP1
66
O
User Definable Enable Pin 1: A TTL output signal allowing control of external logic through the Control
Bus Interface. EP1 is asserted/deasserted through Enable Bit 1 (EB1) of the User Definable Register
(UDR). When Enable Bit 1 is set to zero, EP1 is deasserted. When Enable Bit 1 is set to one, EP1 is
asserted.
EP2
68
O
User Definable Enable Pin 2: A TTL output signal allowing control of external logic through the Control
Bus Interface. EP2 is asserted/deasserted through Enable Bit 2 (EB2) of the User Definable Register
(UDR). When Enable Bit 2 is set to zero, EP2 is deasserted. When Enable Bit 2 is set to one, EP2 is
asserted.
CS
69
I
Cascade Start: A TTL input signal used to synchronize cascaded PLAYER a devices in point-to-point
applications.
The signal is asserted when all of the cascaded PLAYER a devices have the Cascade Mode (CM) bit of
the Mode Register (MR) set to one, and all of the Cascade Ready (CR) pins of the cascaded PLAYER a
devices have been released.
When Cascade Mode is not being used, this input should be tied to Ground.
For further information, refer to section 4.4, Cascade Mode of Operation.
CR
70
O
Cascade Ready: An Open Drain output signal used to synchronize cascaded PLAYER a devices in
point-to-point applications.
The signal is released (i.e. an Open Drain line is released) when all the cascaded PLAYER a devices
have the Cascade Mode (CM) bit of the Mode Register (MR) is set to one and a JK symbol pair has been
received.
When Cascade Mode is not being used, this input should be left Not Connected (N/C).
For further information, refer to section 4.4, Cascade Mode of Operation.
108
6.0 Signal Descriptions (Continued)
POWER AND GROUND
All power pins should be connected to a single a 5V power supply using the recommended filtering. All ground pins should be
connected to a common 0V ground supply. Bypassing and filtering requirements are given in a separate User Information
Document.
Symbol
Pin Ý
VCCÐANALOG
32
I/O
Description
Power: Positive 5V power supply for the PLAYER a device’s CGM VCO.
GNDÐANALOG
33
Ground: Power supply return for the PLAYER a device’s CGM VCO.
VCCÐCORE
140
Power: Positive 5V power supply for the core PLAYER logic gates.
GNDÐCORE
139
Ground: Power supply return for the core PLAYER logic gates.
VCCÐECL
52, 57,
71, 89
Power: Positive 5V power supply for the PLAYER a device’s ECL logic gates.
GNDÐECL
58, 72,
88
Ground: Power supply return for the PLAYER a device’s ECL logic gates.
VCCÐESD
47
GNDÐESD
48
Power: Positive 5V power supply for the PLAYER a device’s ESD protection circuitry.
Ground: Power supply return for the PLAYER a device’s ESD protection circuitry.
VCCÐIO
16, 105,
131, 158
Power: Positive 5V power supply for the input/output buffers.
GNDÐIO
17, 104,
130, 157
Ground: Power supply return for the input/output buffers.
SPECIAL CONNECT PINS
These are pins that have special connection requirements.
No Connect (N/C) pins should not be connected to anything. This means not to power, not to ground, and not to each other.
ReservedÐ0 (RESÐ0) pins must be connected to ground. These pins are not used to supply device power so they do not need
to be filtered or bypassed.
ReservedÐ1 (RESÐ1) pins must be connected to power. These pins are not used to supply device power so they do not need
to be filtered or bypassed.
Symbol
Pin Ý
I/O
Description
N/C
38, 39,
40, 41, 42, 43, 44,
79,
80, 81, 87,
121, 122, 123, 124, 125,
126, 127,
149,
150, 151, 152, 153,154,
155, 156
No Connect: Pins should not be connected to anything. This means not to power, not
to ground, and not to each other.
RESÐ0
28, 29,
30, 31,
84, 85, 86,
90, 91, 92, 93,
136
Reserved 0: Pins must be connected to ground. These pins are not used to supply
device power so they do not need to be filtered or bypassed.
RESÐ1
137
Reserved 1: Pins must be connected to power. These pins are not used to supply
device power so they do not need to be filtered or bypassed.
109
7.0 Electrical Characteristics
7.1 ABSOLUTE MAXIMUM RATINGS
Max
Units
VCC
Symbol
Supply Voltage
Parameter
Conditions
b 0.5
Min
Typ
7.0
V
DCIN
Input Voltage
b 0.5
VCC a 0.5
V
DCOUT
Output Voltage
b 0.5
VCC a 0.5
V
0.3
V
VCCÐESD to other VCC
Maximum Voltage
Differential
Storage Temperature
ECL
b 65
Signal Output Current
ESD Protection
150
§C
b 50
mA
2000
V
7.2 RECOMMENDED OPERATING CONDITIONS
Symbol
Parameter
VCC
Supply Voltage
TA
Operating Temperature
FREF
Conditions
Min
Reference Input Frequency
Max
Units
4.75
Typ
5.25
V
0
70
§C
12.5 – 50 ppm
12.5 a 50 ppm
MHz
12.5
7.3 RECOMMENDED EXTERNAL COMPONENTS
Symbol
XTAL
Parameter
Conditions
Min
Typ
Max
Units
Crystal Specifications
Center Frequency
12.5
Frequency Calibration
Frequency Stability
Over Temperature
Aging
Less Than
MHz
b 10
10
ppm
b 10
10
ppm
5
ppm
b5
Recommended Power Supply Bypassing Capacitor Value
0.1
mF
Note: Capacitors should be placed between each supply pair as close to the
device as possible.
7.4 DC ELECTRICAL CHARACTERISTICS
The DC characteristics are specified over the Recommended Operating Conditions, unless otherwise specified.
DC Electrical Characteristics for All TTL-Compatible Inputs
The following signals are covered: PHY Port Request Signals (ARD, ARC, ARP, BRD, BRC, BRP), Phase Select (PHÐSEL),
Reference Select (REFÐSEL), Sense Pins (SP), Cascade Start (CS), PMD Transmitter Enable Level (TEL), Device Reset
( E RST), and Control Bus Interface Inputs (R/ E W, E CE, CBA).
Symbol
Parameter
Conditions
Min
Typ
Max
Units
0.8
V
VIH
Input High Voltage
2.0
VIL
Input Low Voltage
VIC
Input Clamp Voltage
IIN e b18 mA
b 1.5
V
IIL
Input Low Current
VIN e GND
b 10
mA
IIH
Input High Current
VIN e VCC
a 10
mA
110
V
7.0 Electrical Characteristics (Continued)
DC Electrical Characteristics for All TTL-Compatible Non-TRI-STATE Outputs
The following signals are covered: Clock 16/32 (CLK16), Enable Pins (EP), and PMD Transmitter Enable (TXE).
Parameter
Conditions
Min
VOH
Symbol
Output High Voltage
IOH e b2 mA
VCC b 0.5
VOL
Output Low Voltage
IOL e 4 mA
Typ
Max
Units
V
0.5
V
Max
Units
DC Electrical Characteristics for All TTL-Compatible TRI-STATE Outputs
The following signals are covered: PHY Port Indicate Signals (AID, AIC, AIP, BID, BIC, BIP).
Symbol
Parameter
Conditions
Min
Output High Voltage
IOH e b2 mA
VCC b 0.5
VOL
Output Low Voltage
IOL e 4 mA
0.5
V
IOZ3
TRI-STATE Leakage
VOUT e VCC
(Note 1)
60
mA
IOZ4
TRI-STATE Leakage
VOUT e VGND
(Note 1)
b 500
mA
Max
Units
VOH
Typ
V
Note 1: Output buffer has a p-channel pullup device.
DC Electrical Characteristics for All TTL-Compatible Input/Outputs
The following signals are covered: Control Bus Interface I/O (CBD, CBP).
Symbol
Parameter
VIH
Input High Voltage
VIL
Input Low Voltage
Conditions
Min
Typ
2.0
V
0.8
V
VIC
Input Clamp Voltage
IIN e b18 mA
IIL
Input Low Current
VIN e GND
IIH
Input High Current
VIN e VCC
VOH
Output High Voltage
IOH e b2 mA
VOL
Output Low Voltage
IOL e 4 mA
0.5
V
IOZ1
TRI-STATE Leakage
VOUT e VCC
10
mA
IOZ2
TRI-STATE Leakage
VOUT e VGND
b 10
mA
111
b 1.5
V
b 10
mA
a 10
mA
VCC b 0.5
V
7.0 Electrical Characteristics (Continued)
DC Electrical Characteristics for All FDDI Clock Outputs
The following signals are covered: Local Byte Clocks (LBC1 – LBC5), and Local Symbol Clock (LSC).
These outputs are designed to drive capacitive loads from 20 pF to 60 pF.
Symbol
Parameter
Conditions
Min
VOH
Output High Voltage
IOH e b400 mA
VCC b 2
VOL
Output Low Voltage
IOL e 8 mA
Typ
Max
Units
V
0.5
V
DC Electrical Characteristics for All Clock Reference Inputs
The following signals are covered: Reference In (REFÐIN) and Feedback In (FBKÐIN).
Symbol
Parameter
Max
Units
0.8
V
IIN e b18 mA
b 1.5
V
Input Low Current
VIN e GND
b 10
mA
Input High Current
VIN e VCC
a 10
mA
VIH
Input High Voltage
VIL
Input Low Voltage
VIC
Input Clamp Voltage
IIL
IIH
Conditions
Min
Typ
2.0
V
DC Electrical Characteristics for Crystal Inputs and Outputs
The following signals are covered: Crystal In (XTALÐIN) and Crystal Out (XTALÐOUT).
Symbol
Parameter
Conditions
IOL
Output Low Current
VOUT e 1V
(Note A)
IOH
Output High Current
VTH
Min
Typ
Max
Units
4
mA
VOUT e VCC b 1V
(Note A)
b4
mA
Small Signal Gain
XTALÐIN e 100 mV
Centered about VTH
(Note A)
45
Input Threshold
Voltage
(Note A)
2.2
V
XTALÐIN to
XTALÐOUT Delay
(Note A)
7.0
ns
Output Impedance
(Note A)
270
X
Internal Resistor
Variation
(Note A)
10
kX
Note A: This parameter is presented as a typical value to provide enough information to design an appropriate crystal network.
DC Electrical Characteristics for All Open Drain Outputs
The following signals are covered: Interrupt ( E INT), Acknowledge ( E ACK), and Cascade Ready (CR).
Parameter
Conditions
VOL
Symbol
Output Low Voltage
IOL e 8 mA
0.5
V
IOZ
TRI-STATE Leakage
VOUT e VCC
10
mA
112
Min
Typ
Max
Units
7.0 Electrical Characteristics (Continued)
DC Electrical Characteristics for All 100K ECL Compatible Inputs
The following signals are covered: PMD Indicate Data (PMID), Receive Clock In (RXCÐIN), Receive Data In (RXDÐIN), and
Signal Detect (SD).
Symbol
Parameter
Conditions
VDIFF
Input Voltage Differential
(Note 1)
VCM
Common Mode Voltage
VDIFF e 300 mV
(Notes 1, 2)
IIN
Input Current
VIN e VCC or GND
Min
Typ
Max
150
Units
mV
VCC b 2.0
VCC b 0.5
V
b 200
200
mA
Note 1: Both inputs of each differential pair are tested together. These specifications guarantee that the inputs are compatible with standard 100K ECL voltage
level outputs.
Note 2: VCM is measured from the crossover point of the 300 mV differential test input.
DC Electrical Characteristics for 100K ECL Compatible Outputs
The following signals are covered: PMD Request Data (PMRD) and Transmit Clock (TXC).
Parameter
Conditions
Min
Max
Units
VOH
Symbol
Output High Voltage
VCC b 1.025
VCC b 0.880
V
VOL
Output Low Voltage
VIL e VCC b 1.810
VIH e VCC b 0.880
Typ
VCC b 1.810
VCC b 1.620
V
DC Electrical Characteristics for Alternate PMD ECL Outputs
The following signals are covered: Receive Clock Out (RXCÐOUT) and Receive Data Out (RXDÐOUT).
Parameter
Conditions
Min
Max
Units
VOH
Symbol
Output High Voltage
VCC b 1.155
VCC b 0.880
V
VOL
Output Low Voltage
VIL e VCC b 1.810
VIH e VCC b 0.880
(Note 3)
Typ
VCC b 1.810
VCC b 1.550
V
Note 3: It is recommended that RXCÐOUT a and RXCÐOUT b always be used together as a differential pair. It is recommended that RXDÐOUT a and
RXDÐOUT b always be used together as a differential pair.
Supply Current Electrical Characteristics
Symbol
Parameter
Conditions
Min
Typ
Max
Units
350*
mA
ICC
Total Supply
LBC1 e 12.5 MHz
ECLÐICC
ECL Supply Current
LBC1 e 12.5 MHz
200*
mA
ANALOGÐICC
ANALOG Supply Current
LBC1 e 12.5 MHz
20*
mA
*Note: The PLAYER a device has multiple pairs of differential ECL outputs that need to be terminated. The additional current needed for this termination is not
included in the PLAYER a ’s total supply current, but can be calculated as follows:
VOHÐmax e VCC b 0.88V
VOLÐmax e VCC b 1.62V
Since the outputs are differential, the average output level is VCC b 1.25V. The test load per output is 50X at VCC b 2V, therefore the external load current
through the 50X resistor is:
ILOAD e [(VCC b 1.25) b (VCC b 2)]/50
e 0.015A
e 15 mA
As a result, the termination for each pair of active ECL outputs typically consumes 30 mA, time averaged.
113
7.0 Electrical Characteristics (Continued)
7.5 AC ELECTRICAL CHARACTERISTICS
The AC Electrical characteristics are specified over the Recommended Operating Conditions, unless otherwise specified.
AC Characteristics for the Control Bus Interface
The following signals are covered: Control Bus Interface (R/ E W, E CE, E INT, E ACK, CBA, CBD, and CBP).
Symbol
Descriptions
Min
Max
Units
T1
CE Setup to LBC
15
T2
LBC Period
80
T3
LBC1 to ACK Low
T4
CE Low to ACK Low
T5
LBC1 Low to CBD(7–0) and CBP Valid
T6
LBC1 to CBD(7–0) and CBP Active
T7
CE Low to CBD(7–0) and CBP Active
225
475
T8
CE Low to CBD(7–0) and CBP Valid
265
515
ns
T9
LBC Pulse Width High
35
45
ns
T10
LBC Pulse Width Low
35
T11
CE High to ACK High
T12
R/W, CBA(5–0), CBD(7–0) and CBP Setup to CE Low
5
ns
T13
CE High to R/W, CBA(5–0), CBD(7–0) and CBP Hold Time
0
ns
T14
R/W, CBA(5–0), CBD(7–0) and CBP to LBC1 Setup Time
20
ns
T15
ACK Low to CE High Lead Time
0
ns
T16
CE Minimum Pulse Width High
20
T17
CE High to CBD(7–0) and CBP TRI-STATE
T18
ACK High to CE Low
0
ns
T19
CBD(7–0) Valid to ACK Low Setup
20
ns
T20a
LBC1 to R/W Hold Time
10
ns
T20b
LBC1 to CBA Hold Time
10
ns
T20c
LBC1 to CBD and CBP Hold Time
20
ns
T21
LBC1 to INT Low
T22
LBC1 to EP Change
290
T1 a (3 * T2) a T3
T4 (max)
T1 a (6 * T2) a T3
T7 (min)
T1 a (2 * T2) a T6
T7 (max)
T1 a (5 * T2) a T6
T8 (min)
T1 a (2 * T2) a T9 a T5
T8 (max)
T1 a (5 * T2) a T9 a T5
ns
45
ns
540
ns
60
ns
5
Note: Min/Max numbers are based on T2 e 80 ns and T9 e T10 e 40 ns.
114
ns
ns
45
ns
45
ns
ns
55
5
Asynchronous Definitions
T4 (min)
ns
ns
55
ns
25
ns
7.0 Electrical Characteristics (Continued)
TL/F/11708 – 29
FIGURE 7-1. Asynchronous Control Bus Write Cycle Timing
TL/F/11708 – 30
FIGURE 7-2. Asynchronous Control Bus Read Cycle Timing
115
7.0 Electrical Characteristics (Continued)
TL/F/11708 – 31
FIGURE 7-3. Control Bus Synchronous Writes
TL/F/11708 – 32
FIGURE 7-4. Control Bus Synchronous Reads
TL/F/11708 – 50
FIGURE 7-5. Control Bus Interrupt Timing
116
7.0 Electrical Characteristics (Continued)
AC Characteristics for the Clock Interface Signals (Timing and Relationships)
Symbol
Parameter
Min
Typ
Max
Units
TPhase1
LBC1–LBC2 Timing
PHÐSEL e LOW
5.0
8
11.0
ns
TPhase2
LBC1–LBC3 Timing
PHÐSEL e LOW
13.0
16
19.0
ns
TPhase3
LBC1–LBC4 Timing
PHÐSEL e LOW
21.0
24
27.0
ns
TPhase4
LBC1–LBC5 Timing
PHÐSEL e LOW
29.0
32
35.0
ns
TPhase1
LBC1–LBC2 Timing
PHÐSEL e HIGH
45.0
48
51.0
ns
TPhase2
LBC1–LBC3 Timing
PHÐSEL e HIGH
13.0
16
19.0
ns
TPhase3
LBC1–LBC4 Timing
PHÐSEL e HIGH
61.0
64
67.0
ns
TPhase4
LBC1–LBC5 Timing
PHÐSEL e HIGH
29.0
32
35.0
ns
TPhase5
LBC5 RisingLBC1 Falling Timing
PHÐSEL e LOW or
PHÐSEL e HIGH
5.0
8
12.0
ns
T23
LSC Falling to LBC1
(Note 1)
b3
a6
ns
b2
a2
ns
T24
REFÐIN to FBKÐIN
Conditions
In Lock
Note 1: LSC loading must always be less than or equal to LBC1 loading.
TL/F/11708 – 33
FIGURE 7-6. Clock Signal Relationships
117
7.0 Electrical Characteristics (Continued)
TL/F/11708 – 51
FIGURE 7-7. Typical Clock Signal Relationships Based on Phase Select (PHÐSEL) Setting
118
7.0 Electrical Characteristics (Continued)
AC Characteristics for the Clock Interface Signals (Periods and Pulse Widths)
Symbol
Parameter
Conditions
Min
Typ
Max
80
Units
T2
LBC Period
T9
LBC Pulse Width High
35
45
ns
ns
T10
LBC Pulse Width Low
35
45
ns
T25
LSC Pulse Width High
12
19
ns
T26
LSC Pulse Width Low
21
28
ns
T27
CLK16 Period
MODE2.CLKSEL e 0
T28
CLK16 Pulse Width
MODE2.CLKSEL e 0
(Note 1)
T27
CLK16 Period
MODE2.CLKSEL e 1
T28
CLK16 Pulse Width
MODE2.CLKSEL e 1
(Note 1)
T29
REFÐIN Pulse Width High
64
27
32
ns
37
32
11
16
35
ns
ns
21
ns
45
ns
Note 1: This parameter is not tested, but is assured by correlation with characterization data.
TL/F/11708 – 34
FIGURE 7-8. Clock Pulse Widths
AC Characteristics for Port A Interface and Port B Interface
The following signals are covered: PHY Port A (AID, AIP, AIC, ARD, ARP, ARC) and PHY Port B (BID, BIP, BIC, BRD, BRP,
BRC).
Max
Units
T30
Symbol
LBC1 to Indicate Data Changes from
TRI-STATE to Valid Data
Parameter
Conditions
Min
Typ
70
ns
T31
LBC1 to Indicate Data Changes from
Active to TRI-STATE
70
ns
T32
LBC1 to Indicate Data Sustain
T33
LBC1 to Valid Indicate Data
T34
Request Data to LBC1 Setup Time
15
ns
T35
Request Data to LBC1 Hold Time
3
ns
9
ns
45
TL/F/11708 – 35
FIGURE 7-9. PHY Port Interface Timing
119
ns
7.0 Electrical Characteristics (Continued)
AC Characteristics for the PMD Interface
The following signals are covered: PMD Indicate Data (PMID), Signal Detect (SD), and PMD Request Data (PMRD).
Symbol
Parameter
Conditions
Min
Typ
Max
T36
PMID g to PMRD g Latency
Looped Back through
Configuration Switch.
LBC1 e 12.5 MHz
In Lock
(Note 1)
T37
SD Minimum Pulse Width
T38
PMRD Rise Time
(Note 2)
1.5
ns
T39
PMRD Fall Time
(Note 2)
1.5
ns
5
LBC
Cycles
120
ns
Note 1: This only applies when the Alternate PMD Interface is disabled, APMDREG.APMDEN e 0.
Note 2: This parameter is not tested, but is assured by correlation with characterization data.
TL/F/11708 – 36
FIGURE 7-10. Primary PMD Timing Diagrams
120
Units
7.0 Electrical Characteristics (Continued)
AC Characteristics for the Alternate PMD Interface
The following input signals are covered: PMD Indicate Data (PMID), Signal Detect (SD), Receive Data In (RXDÐIN), Receive
Clock In (RXCÐIN).
The following output signals are covered: PMD Request Data (PMRD), Transmit Clock (TXC), Recovered Data Out
(RXDÐOUT), Recovered Clock Out (RXCÐOUT).
Note: The Alternate PMD Interface is only available on the 160 pin DP83257 PLAYER a Device and the 100 pin DP83256-AP Device. The Transmit Clock is
enabled by the CGMREG.TXCE bit. The rest of the Alternate PMD Interface is enabled by the APMDREG.APMDEN bit.
Symbol
Parameter
Conditions
Min
T40
RXCÐOUT a to RXDÐOUT g Change Time
T41
PMID g to RXDÐOUT Latency
T42
RXDÐIN g to RXCÐIN a Setup Time
4.0
T43
RXDÐIN g to RXCÐIN a Hold Time
0.5
T44
TXC a to PMRD g Change Time
4.0
T42
SD Minimum Pulse Width
120
T45
RXCÐOUT g Pulse Width High
(Note 1)
T46
RXCÐOUT g Rise Time
T47
RXCÐOUT g Fall Time
T48
Typ
1.0
In Lock
Max
Units
5.0
ns
16
ns
ns
ns
7.0
ns
ns
3.5
4.5
ns
(Note 1)
1.5
ns
(Note 1)
1.5
ns
RXDÐOUT g Rise Time
(Note 1)
1.5
ns
T49
RXDÐOUT g Fall Time
(Note 1)
1.5
ns
T50
TXC g Pulse Width High
(Note 1)
4.5
ns
T51
TXC g Rise Time
(Note 1)
1.5
ns
T52
TXC g Fall Time
(Note 1)
1.5
ns
T38
PMRD Rise Time
(Note 1)
1.5
ns
T39
PMRD Fall Time
(Note 1)
1.5
ns
3.5
Note 1: This parameter is not tested, but is assured by correlation with characterization data.
TL/F/11708 – 52
FIGURE 7-11. ECL Rise and Fall Times
121
7.0 Electrical Characteristics (Continued)
TL/F/11708 – 53
FIGURE 7-12. Alternate PMD Timing Diagrams
122
7.0 Electrical Characteristics (Continued)
AC Characteristics for the PMD Interface Inputs (ANSI Specifications)
The following input signals are covered: PMD Indicate Data (PMID), Receive Data In (RXDÐIN), Receive Clock In (RXCÐIN).
Note: The Alternate PMD Interface is only available on the 160 pin DP83257 PLAYER a Device and the 100 pin DP83256-AP Device. The Transmit Clock is
enabled by the CGMREG.TXCE bit. The rest of the Alternate PMD Interface is enabled by the APMDREG.APMDEN bit.
All comments in square brackets are section references to the ANSI documents where these specifications can be found.
Symbol
Parameter
Conditions
Max
Units
b3
3
ns
b 100
100
ppm
From 1st Data
and SD Active
[PHY 5.2.6]
100
ms
From Line State
Change
[PHY 5.2.6]
15
ms
T53
CRM Window Recognition Region
(PMID Inputs)
[PMD E.2]
T54
PMID Receive Clock Tolerance
(Lock Acquisition Range)
[PHY 5.2.4]
T55
Receive Clock Acquisition Time
T56
Receive Clock Acquisition Time
Min
Typ
TL/F/11708 – 54
TL/F/11708 – 55
FIGURE 7-13. Alternate PMD Input Timing DiagramsÐANSI Specifications
123
7.0 Electrical Characteristics (Continued)
AC Characteristics for the PMD Interface Outputs (ANSI Specifications)
The following output signals are covered: PMD Request Data (PMRD), Transmit Clock (TXC), Recovered Data Out
(RXDÐOUT), Recovered Clock Out (RXCÐOUT).
Note: The Alternate PMD Interface is only available on the 160 pin DP83257 PLAYER a Device and the 100 pin DP83256-AP Device. The Transmit Clock is
enabled by the CGMREG.TXCE bit. The rest of the Alternate PMD Interface is enabled by the APMDREG.APMDEN bit.
Comments in square brackets are section references to the ANSI documents where these specifications can be found.
Max
Units
T57
Symbol
PMRD Total Transmit Jitter
[Duty Cycle Distortion (DCD) a
Data Dependent Jitter (DDJ) a
Random Jitter (RJ)]
Parameter
(Note 1)
[PMD 8.1]
Conditions
Min
0.72
ns p-p
T58
Total Recovered Clock (RXCÐOUT) Jitter
[Static Alignment Error Accuracy (SAE) a
Clock Data Dependent Jitter (CÐDDJ) a
Random Jitter (CÐRJ)]
(Note 1)
[PMD E.2]
2.5
ns p-p
Note 1: This parameter is not tested, but is assured through characterization data and periodic testing of sample units.
124
Typ
7.0 Electrical Characteristics (Continued)
AC Characteristics for User Definable Pins
The following signals are covered: Sense Pins (SP).
For Enable Pins (EP) timing see AC Characteristics for the Control Bus Interface.
Symbol
T59
Parameter
Conditions
Min
SP Minimum Pulse Width
Typ
Max
Units
120
ns
TL/F/11708 – 56
FIGURE 7-14. SP Minimum Pulse Width
AC Characteristics for Miscellaneous Interface
The following signal is covered: Reset ( E RST).
Symbol
Parameter
Conditions
T60
Minimum Reset ( E RST) Pulse Width
T61
Maximum Power Up Reset Cycle Duration
T62
Maximum Hardware Reset ( E RST) Cycle Duration
Min
Typ
Max
Units
10
ms
0.5
ms
300
(Notes 1, 2)
ns
Note 1: This parameter is not tested, but is assured by correlation with characterization data.
Note 2: User must wait this long before trying to access the device after power up. It is recommended that a Hardware Reset be used sometime after the Power Up
Reset cycle is complete to insure proper device reset.
TL/F/11708 – 57
FIGURE 7-15. Reset Timing
125
7.0 Electrical Characteristics (Continued)
AC TEST CIRCUITS
TL/F/11708 – 37
Note: S1 is closed for TPZL and TPLZ
S2 is closed for TPZH and TPHZ
S1 and S2 are open otherwise
FIGURE 7-16. Switching Test Circuit for All TRI-STATE Output Signals
TL/F/11708 – 38
FIGURE 7-17. Switching Test Circuit for All TTL Output Signals
TL/F/11708 – 39
FIGURE 7-18. Switching Test Circuit for All Open Drain Output Signals (INT, ACK, and CR)
TL/F/11708 – 40
FIGURE 7-19. Switching Test Circuit for All ECL Input and Output Signals
126
7.0 Electrical Characteristics (Continued)
TEST WAVEFORMS
TL/F/11708 – 41
FIGURE 7-20. ECL Output Test Waveform
TL/F/11708 – 42
Note: All CMOS Inputs and outputs are TTL compatible.
FIGURE 7-21. TTL Output Test Waveform
TL/F/11708 – 43
FIGURE 7-22. TRI-STATE Output Test Waveform
127
8.0 Connection Diagrams
8.1 DP83256VF CONNECTION DIAGRAM
For a Pinout Summary List, refer to Table 8-1.
TL/F/11708 – 44
FIGURE 8-1. DP83256VF 100-Pin JEDEC Metric PQFP Pinout
128
8.0 Connection Diagrams (Continued)
TABLE 8-1. DP83256 100-Pin PQFP Pinout Summary
Pin No.
Symbol
I/O
Pin Type
1
Local Byte Clock 4
Signal Name
LBC4
O
TTL
2
Local Byte Clock 3
LBC3
O
TTL
3
Local Byte Clock 2
LBC2
O
TTL
4
Local Byte Clock 1
LBC1
O
TTL
5
Clock 16/32
CLK16
O
TTL
6
PHY Port A Indicate Parity
AIP
O
TTL
7
PHY Port A Indicate Control
AIC
O
TTL
8
PHY Port A Indicate Datak7l
AID7
O
TTL
9
PHY Port A Indicate Datak6l
AID6
O
TTL
10
PHY Port A Indicate Datak5l
AID5
O
11
I/O Power
VCCÐIO
a 5V
12
I/O Ground
GNDÐIO
a 0V
13
PHY Port A Indicate Datak4l
AID4
O
TTL
14
PHY Port A Indicate Datak3l
AID3
O
TTL
15
PHY Port A Indicate Datak2l
AID2
O
TTL
16
PHY Port A Indicate Datak1l
AID1
O
TTL
17
PHY Port A Indicate Datak0l
AID0
O
18
ReservedÐ0
19
ReservedÐ0
20
ANALOG Power
TTL
TTL
RESÐ0
a 0V
RESÐ0
a 0V
VCCÐANALOG
a 5V
GNDÐANALOG
a0 V
21
ANALOG Ground
22
Phase Select
PHÐSEL
I
TTL
23
Reference Select
REFÐSEL
I
TTL
24
Reference Input
REFÐIN
I
TTL
25
Feedback Input
FBKÐIN
I
TTL
26
Crystal Output
XTALÐOUT
O
27
Crystal Input
XTALÐIN
I
28
ESD Power
VCCÐESD
a 5V
29
ESD Ground
GNDÐESD
a 0V
30
Loop Filter
LPFLTR
31
ECL Power
VCCÐECL
32
PMD Request Data b
PMRDb
O
ECL
33
PMD Request Data a
PMRD a
O
ECL
34
ECL Power
VCCÐECL
35
ECL Ground
GNDÐECL
36
Signal Detect b
SDb
I
ECL
37
Signal Detect a
SD a
I
ECL
38
PMD Indicate Data b
PMIDb
I
ECL
129
O
a 5V
a 5V
a 0V
8.0 Connection Diagrams (Continued)
TABLE 8-1. DP83256 100-Pin PQFP Pinout Summary (Continued)
Pin No.
Signal Name
Symbol
I/O
Pin Type
39
PMD Indicate Data a
PMID a
I
ECL
40
Sense Pin 0
SP0
I
TTL
41
Enable Pin 0
EP0
O
TTL
42
Sense Pin 1
SP1
I
TTL
43
Enable Pin 1
EP1
O
44
ECL Power
VCCÐECL
a 5V
45
ECL Ground
GNDÐECL
a 0V
46
PMD Transmitter Enable
TXE
O
TTL
47
PMD Transmitter Enable Level
TEL
I
TTL
48
ReservedÐ0
RESÐ0
49
No Connect
N/C
50
ReservedÐ0
RESÐ0
a 0V
51
ReservedÐ0
RESÐ0
a 0V
52
ReservedÐ0
RESÐ0
a 0V
53
ReservedÐ0
RESÐ0
a 0V
54
No Connect
N/C
55
ECL Ground
GNDÐECL
a 0V
56
ECL Power
VCCÐECL
a 5V
57
ReservedÐ0
RESÐ0
a 0V
58
ReservedÐ0
RESÐ0
a 0V
59
PHY Port B Request Datak0l
BRD0
I
TTL
60
PHY Port B Request Datak1l
BRD1
I
TTL
61
PHY Port B Request Datak2l
BRD2
I
TTL
62
PHY Port B Request Datak3l
BRD3
I
TTL
63
PHY Port B Request Datak4l
BRD4
I
64
I/O Ground
GNDÐIO
65
I/O Power
VCCÐIO
66
PHY Port B Request Datak5l
BRD5
I
TTL
67
PHY Port B Request Datak6l
BRD6
I
TTL
68
PHY Port B Request Datak7l
BRD7
I
TTL
69
PHY Port B Request Control
BRC
I
TTL
70
PHY Port B Request Parity
BRP
O
TTL
71
E Device Reset
E RST
I
TTL
72
Read/ E Write
R/ E W
I
TTL
73
Chip Enable
E CE
I
TTL
74
E Interrupt
E INT
O
Open Drain
75
E Acknowledge
E ACK
O
Open Drain
76
Control Bus Addressk0l
CBA0
I
TTL
130
TTL
a 0V
TTL
a 0V
a 5V
8.0 Connection Diagrams (Continued)
TABLE 8-1. DP83256 100-Pin PQFP Pinout Summary (Continued)
Pin No.
Signal Name
77
Control Bus Addressk1l
Symbol
I/O
CBA1
I
78
I/O Logic Ground
GNDÐIO
79
I/O Logic Power
VCCÐIO
80
Control Bus Addressk2l
CBA2
I
TTL
81
Control Bus Addressk3l
CBA3
I
TTL
82
Control Bus Addressk4l
CBA4
I
TTL
83
Control Bus Addressk5l
CBA5
I
84
ReservedÐ0
RESÐ0
a 0V
85
ReservedÐ1
RESÐ1
a 5V
86
Control Bus Datak0l
87
Core Ground
GNDÐCORE
88
Core Power
VCCÐCORE
89
Control Bus Datak1l
CBD1
I/O
TTL
90
Control Bus Datak2l
CBD2
I/O
TTL
91
Control Bus Datak3l
CBD3
I/O
TTL
92
Control Bus Datak4l
CBD4
I/O
TTL
93
Control Bus Datak5l
CBD5
I/O
TTL
94
Control Bus Datak6l
CBD6
I/O
TTL
95
Control Bus Datak7l
CBD7
I/O
TTL
96
Control Bus Data Parity
CBP
I/O
97
I/O Ground
GNDÐIO
a 0V
98
I/O Power
VCCÐIO
a 5V
CBD0
Pin Type
TTL
a 0V
a 5V
I/O
TTL
TTL
a 0V
a 5V
TTL
99
Local Symbol Clock
LSC
O
TTL
100
Local Byte Clock5
LBC5
O
TTL
131
8.0 Connection Diagrams (Continued)
8.2 DP83256VF-AP CONNECTION DIAGRAM
For a Pinout Summary List, refer to Table 8-2.
TL/F/11708 – 58
FIGURE 8-2. DP83256VF-AP 100-Pin JEDEC Metric PQFP Pinout
132
8.0 Connection Diagrams (Continued)
TABLE 8-2. DP83256VF-AP 100-Pin PQFP Pinout Summary
Pin No.
Symbol
I/O
Pin Type
1
Local Byte Clock 4
Signal Name
LBC4
O
TTL
2
Local Byte Clock 3
LBC3
O
TTL
3
Local Byte Clock 2
LBC2
O
TTL
4
Local Byte Clock 1
LBC1
O
TTL
5
Clock 16/32
CLK16
O
TTL
6
PHY Port A Indicate Parity
AIP
O
TTL
7
PHY Port A Indicate Control
AIC
O
TTL
8
PHY Port A Indicate Datak7l
AID7
O
TTL
9
PHY Port A Indicate Datak6l
AID6
O
TTL
10
PHY Port A Indicate Datak5l
AID5
O
11
I/O Power
VCCÐIO
a 5V
12
I/O Ground
GNDÐIO
a 0V
13
PHY Port A Indicate Datak4l
AID4
O
TTL
14
PHY Port A Indicate Datak3l
AID3
O
TTL
15
PHY Port A Indicate Datak2l
AID2
O
TTL
16
PHY Port A Indicate Datak1l
AID1
O
TTL
17
PHY Port A Indicate Datak0l
AID0
O
18
ReservedÐ0
19
ReservedÐ0
20
ANALOG Power
TTL
TTL
RESÐ0
a 0V
RESÐ0
a 0V
VCCÐANALOG
a 5V
GNDÐANALOG
a0 V
21
ANALOG Ground
22
Phase Select
PHÐSEL
I
TTL
23
Reference Select
REFÐSEL
I
TTL
24
Reference Input
REFÐIN
I
TTL
25
Feedback Input
FBKÐIN
I
TTL
26
Crystal Output
XTALÐOUT
O
27
Crystal Input
XTALÐIN
I
28
ESD Power
VCCÐESD
a 5V
29
ESD Ground
GNDÐESD
a 0V
30
Transmit Clockb
TXCb
O
31
Transmit Clock a
TXC a
O
32
ECL Power
33
PMD Request Data b
34
35
VCCÐECL
ECL
ECL
a 5V
PMRDb
O
ECL
PMD Request Data a
PMRD a
O
ECL
Receive Clock Outb
RXCÐOUTb
O
ECL
36
Receive Clock Out a
RXCÐOUT a
O
37
ECL Power
VCCÐECL
a 5V
38
ECL Ground
GNDÐECL
a 0V
133
ECL
8.0 Connection Diagrams (Continued)
TABLE 8-2. DP83256VF-AP 100-Pin PQFP Pinout Summary (Continued)
Pin No.
Symbol
I/O
Pin Type
39
Signal Detectb
Signal Name
SDb
I
ECL
40
Signal Detect a
SD a
I
ECL
41
PMD Indicate Datab
PMIDb
I
ECL
42
PMD Indicate Date a
PMID a
I
ECL
43
Enable Pin 0
EP0
O
TTL
44
Enable Pin 1
EP1
O
45
ECL Power
VCCÐECL
a 5V
46
ECL Ground
GNDÐECL
a 0V
47
Receive Clock Inb
RXCÐINb
I
ECL
48
Receive Clock In a
RXCÐIN a
I
ECL
49
Receive Data Inb
RXDÐINb
I
ECL
50
Receive Data In a
RXDÐIN a
I
ECL
51
Receive Data Outb
RXDÐOUTb
O
ECL
52
Receive Data Out a
RXDÐOUT a
O
ECL
53
No Connect
N/C
54
No Connect
N/C
55
ECL Ground
GNDÐECL
a 0V
56
ECL Power
VCCÐECL
a 5V
57
ReservedÐ0
RESÐ0
a 0V
58
ReservedÐ0
RESÐ0
a 0V
59
PHY Port B Request Datak0l
BRD0
I
TTL
60
PHY Port B Request Datak1l
BRD1
I
TTL
61
PHY Port B Request Datak2l
BRD2
I
TTL
62
PHY Port B Request Datak3l
BRD3
I
TTL
63
PHY Port B Request Datak4l
BRD4
I
64
I/O Ground
GNDÐIO
65
I/O Power
VCCÐIO
66
PHY Port B Request Datak5l
BRD5
I
TTL
67
PHY Port B Request Datak6l
BRD6
I
TTL
68
PHY Port B Request Datak7l
BRD7
I
TTL
69
PHY Port B Request Control
BRC
I
TTL
70
PHY Port B Request Parity
BRP
O
TTL
71
E Device Reset
E RST
I
TTL
72
Read/ E Write
R/ E W
I
TTL
73
Chip Enable
E CE
I
TTL
74
E Interrupt
E INT
O
Open Drain
75
E Acknowledge
E ACK
O
Open Drain
76
Control Bus Addressk0l
CBA0
I
TTL
134
TTL
TTL
a 0V
a 5V
8.0 Connection Diagrams (Continued)
TABLE 8-2. DP83256VF-AP 100-Pin PQFP Pinout Summary (Continued)
Pin No.
Signal Name
77
Control Bus Addressk1l
Symbol
I/O
CBA1
I
78
I/O Logic Ground
GNDÐIO
79
I/O Logic Power
VCCÐIO
80
Control Bus Addressk2l
CBA2
I
TTL
81
Control Bus Addressk3l
CBA3
I
TTL
82
Control Bus Addressk4l
CBA4
I
TTL
83
Control Bus Addressk5l
CBA5
I
84
ReservedÐ0
RESÐ0
a 0V
85
ReservedÐ1
RESÐ1
a 5V
86
Control Bus Datak0l
87
Core Ground
GNDÐCORE
88
Core Power
VCCÐCORE
89
Control Bus Datak1l
CBD1
I/O
TTL
90
Control Bus Datak2l
CBD2
I/O
TTL
91
Control Bus Datak3l
CBD3
I/O
TTL
92
Control Bus Datak4l
CBD4
I/O
TTL
93
Control Bus Datak5l
CBD5
I/O
TTL
94
Control Bus Datak6l
CBD6
I/O
TTL
95
Control Bus Datak7l
CBD7
I/O
TTL
96
Control Bus Data Parity
CBP
I/O
97
I/O Ground
GNDÐIO
a 0V
98
I/O Power
VCCÐIO
a 5V
CBD0
Pin Type
TTL
a 0V
a 5V
I/O
TTL
TTL
a 0V
a 5V
TTL
99
Local Symbol Clock
LSC
O
TTL
100
Local Byte Clock5
LBC5
O
TTL
135
8.0 Connection Diagrams (Continued)
8.3 DP83257VF CONNECTION DIAGRAM
For a Pinout Summary List, refer to Table 8-3.
TL/F/11708 – 45
FIGURE 8-3. DP83257VF 160-Pin JEDEC Metric PQFP Pinout
136
8.0 Connection Diagrams (Continued)
TABLE 8-3. DP83257 160-Pin PQFP Pinout Summary
Pin No.
Signal Name
Symbol
I/O
Pin Type
1
Local Byte Clock 4
LBC4
O
TTL
2
Local Byte Clock 3
LBC3
O
TTL
3
Local Byte Clock 2
LBC2
O
TTL
4
Local Byte Clock 1
LBC1
O
TTL
5
Clock 16/32
CLK16
O
TTL
6
PHY Port A Indicate Parity
AIP
O
TTL
7
PHY Port A Request Parity
ARP
I
TTL
8
PHY Port A Indicate Control
AIC
O
TTL
9
PHY Port A Request Control
ARC
I
TTL
10
PHY Port A Indicate Datak7l
AID7
O
TTL
11
PHY Port A Request Datak7l
ARD7
I
TTL
12
PHY Port A Indicate Datak6l
AID6
O
TTL
13
PHY Port A Request Datak6l
ARD6
I
TTL
14
PHY Port A Indicate Datak5l
AID5
O
TTL
15
PHY Port A Request Datak5l
ARD5
I
16
I/O Power
VCCÐIO
17
I/O Ground
GNDÐIO
18
PHY Port A Indicate Datak4l
AID4
19
PHY Port A Request Datak4l
20
PHY Port A Indicate Datak3l
21
TTL
a 5V
a 0V
O
TTL
ARD4
I
TTL
AID3
O
TTL
PHY Port A Request Datak3l
ARD3
I
TTL
22
PHY Port A Indicate Datak2l
AID2
O
TTL
23
PHY Port A Request Datak2l
ARD2
I
TTL
24
PHY Port A Indicate Datak1l
AID1
O
TTL
25
PHY Port A Request Datak1l
ARD1
I
TTL
26
PHY Port A Indicate Datak0l
AID0
O
TTL
27
PHY Port A Request Datak0l
ARD0
I
28
ReservedÐ0
RESÐ0
a 0V
29
ReservedÐ0
RESÐ0
a 0V
30
ReservedÐ0
RESÐ0
a 0V
31
ReservedÐ0
RESÐ0
a 0V
32
ANALOG Power
VCCÐANALOG
a 5V
33
ANALOG Ground
GNDÐANALOG
34
Phase Select
35
TTL
a 0V
PHÐSEL
I
TTL
Reference Select
REFÐSEL
I
TTL
36
Reference Input
REFÐIN
I
TTL
37
Feedback Input
FBKÐIN
I
TTL
38
No Connect
N/C
137
8.0 Connection Diagrams (Continued)
TABLE 8-3. DP83257 160-Pin PQFP Pinout Summary (Continued)
Pin No.
Signal Name
Symbol
39
No Connect
N/C
40
No Connect
N/C
41
No Connect
N/C
42
No Connect
N/C
43
No Connect
N/C
44
No Connect
45
Crystal Output
46
I/O
Pin Type
N/C
XTALÐOUT
O
Crystal Input
XTALÐIN
I
47
ESD Power
VCCÐESD
a 5V
48
ESD Ground
GNDÐESD
a 0V
49
Loop Filter
LPFLTR
O
50
Transmit Clockb
TXCb
O
51
Transmit Clock a
TXC a
O
52
ECL Power
53
PMD Request Datab
PMRDb
O
ECL
54
PMD Request Data a
PMRD a
O
ECL
55
Receive Clock Outb
RXCÐOUTb
O
ECL
56
Receive Clock Out a
RXCÐOUT a
O
VCCÐECL
ECL
ECL
a 5V
ECL
57
ECL Power
VCCÐECL
58
ECL Ground
GNDÐECL
59
Signal Detectb
SDb
I
ECL
60
Signal Detect a
SD a
I
ECL
61
PMD Indicate Datab
PMIDb
I
ECL
62
PMD Indicate Data a
PMID a
I
ECL
63
Sense Pin 0
SP0
I
TTL
64
Enable Pin 0
EP0
O
TTL
65
Sense Pin 1
SP1
I
TTL
66
Enable Pin 1
EP1
O
TTL
67
Sense Pin 2
SP2
I
TTL
68
Enable Pin 2
EP2
O
TTL
69
Cascade Start
CS
I
TTL
70
Cascade Ready
CR
O
Open Drain
71
ECL Power
VCCÐECL
72
ECL Ground
GNDÐECL
73
PMD Transmitter Enable
74
PMD Transmitter Enable Level
TEL
I
TTL
75
Receive Clock Inb
RXCÐINb
I
ECL
76
Receive Clock In a
RXCÐIN a
I
ECL
TXE
138
a 5V
a 0V
a 5V
a 0V
O
TTL
8.0 Connection Diagrams (Continued)
TABLE 8-3. DP83257 160-Pin PQFP Pinout Summary (Continued)
Pin No.
Symbol
I/O
Pin Type
77
Receive Data Inb
Signal Name
RXDÐINb
I
ECL
78
Receive Data In a
RXDÐIN a
I
ECL
79
No Connect
N/C
80
No Connect
N/C
81
No Connect
N/C
82
Receive Data Outb
RXDÐOUTb
O
ECL
83
Receive Data Out a
RXDÐOUT a
O
84
ReservedÐ0
RESÐ0
a 0V
85
ReservedÐ0
RESÐ0
a 0V
86
ReservedÐ0
RESÐ0
a 0V
87
No Connect
N/C
88
ECL Ground
GNDÐECL
a 0V
89
ECL Power
VCCÐECL
a 5V
90
ReservedÐ0
RESÐ0
a 0V
91
ReservedÐ0
RESÐ0
a 0V
92
ReservedÐ0
RESÐ0
a 0V
93
ReservedÐ0
RESÐ0
94
PHY Port B Indicate Datak0l
BID0
95
PHY Port B Request Datak0l
96
PHY Port B Indicate Datak1l
97
ECL
a 0V
O
TTL
BRD0
I
TTL
BID1
O
TTL
PHY Port B Request Datak1l
BRD1
I
TTL
98
PHY Port B Indicate Datak2l
BID2
O
TTL
99
PHY Port B Request Datak2l
BRD2
I
TTL
100
PHY Port B Indicate Datak3l
BID3
O
TTL
101
PHY Port B Request Datak3l
BRD3
I
TTL
102
PHY Port B Indicate Datak4l
BID4
O
TTL
103
PHY Port B Request Datak4l
BRD4
I
104
I/O Ground
GNDÐIO
105
I/O Power
VCCÐIO
106
PHY Port B Indicate Datak5l
BID5
107
PHY Port B Request Datak5l
108
PHY Port B Indicate Datak6l
109
PHY Port B Request Datak6l
110
111
112
113
114
TTL
a 0V
a 5V
O
TTL
BRD5
I
TTL
BID6
O
TTL
BRD6
I
TTL
PHY Port B Indicate Datak7l
BID7
O
TTL
PHY Port B Request Datak7l
BRD7
I
TTL
PHY Port B Indicate Control
BIC
O
TTL
PHY Port B Request Control
BRC
I
TTL
PHY Port B Indicate Parity
BIP
O
TTL
139
8.0 Connection Diagrams (Continued)
TABLE 8-3. DP83257 160-Pin PQFP Pinout Summary (Continued)
Pin No.
Signal Name
Symbol
I/O
Pin Type
115
PHY Port B Request Parity
BRP
I
TTL
116
E Device Reset
E RST
I
TTL
117
Read/ E Write
R/ E W
I
TTL
118
Chip Enable
E CE
I
TTL
119
E Interrupt
E INT
O
Open Drain
120
E Acknowledge
E ACK
O
Open Drain
121
No Connect
N/C
122
No Connect
N/C
123
No Connect
N/C
124
No Connect
N/C
125
No Connect
N/C
126
No Connect
N/C
127
No Connect
128
Control Bus Addressk0l
CBA0
I
TTL
129
Control Bus Addressk1l
CBA1
I
130
I/O Logic Ground
GNDÐIO
131
I/O Logic Power
VCCÐIO
132
Control Bus Addressk2l
CBA2
I
TTL
133
Control Bus Addressk3l
CBA3
I
TTL
134
Control Bus Addressk4l
CBA4
I
TTL
135
Control Bus Addressk5l
CBA5
I
136
ReservedÐ0
RESÐ0
a 0V
137
ReservedÐ1
RESÐ1
a 5V
138
Control Bus Datak0l
139
Core Ground
GNDÐCORE
a 0V
140
Core Power
VCCÐCORE
a 5V
141
Control Bus Datak1l
CBD1
I/O
TTL
142
Control Bus Datak2l
CBD2
I/O
TTL
143
Control Bus Datak3l
CBD3
I/O
TTL
144
Control Bus Datak4l
CBD4
I/O
TTL
145
Control Bus Datak5l
CBD5
I/O
TTL
146
Control Bus Datak6l
CBD6
I/O
TTL
147
Control Bus Datak7l
CBD7
I/O
TTL
148
Control Bus Data Parity
CBP
I/O
TTL
149
No Connect
N/C
150
No Connect
N/C
151
No Connect
N/C
N/C
CBD0
140
TTL
a 0V
a 5V
I/O
TTL
TTL
8.0 Connection Diagrams (Continued)
TABLE 8-3. DP83257 160-Pin PQFP Pinout Summary (Continued)
Pin No.
Signal Name
Symbol
I/O
Pin Type
152
No Connect
N/C
153
No Connect
N/C
154
No Connect
N/C
155
No Connect
N/C
156
No Connect
N/C
157
I/O Ground
GNDÐIO
158
I/O Power
VCCÐIO
159
Local Symbol Clock
LSC
O
TTL
160
Local Byte Clock5
LBC5
O
TTL
141
a 0V
a 5V
9.0 Package Information
The information contained in this section describes the two packages used for the PLAYER a device.
Land pattern information is provided to assist in surface mount layout using each of the available PLAYER a device packages.
Mechanical drawings of each of the packages are also provided.
9.1 LAND PATTERNS
TL/F/11708 – 46
FIGURE 9-1. Layout Land Patterns
TABLE 9-1. Layout Land Pattern Dimensions
Device
A (mm)
B (mm)
P (mm)
X (mm)
DP83256VF and DP83256VF-AP
14mm x 14mm x 2.0mm
100-lead JEDEC FPQFP
14.60
18.45
0.50
0.35
DP83257VF
28mm x 28mm x 3.42mm
160-lead JEDEC MQFP
28.90
33.40
0.65
0.45
9.2 MECHANICAL DRAWINGS
The following two pages contain the mechanical drawings for each of the available PLAYER a device packages.
142
Physical Dimensions millimeters
Plastic Quad Flatpak (VJU)
Order Number DP83256VF and DP83256VF-AP
NS Package Number VJU100A
143
DP83256/56-AP/57 PLAYER a Device (FDDI Physical Layer Controller)
Physical Dimensions millimeters (Continued)
Plastic Quad Flatpak (V)
Order Number DP83257VF
NS Package Number VUL160A
LIFE SUPPORT POLICY
NATIONAL’S PRODUCTS ARE NOT AUTHORIZED FOR USE AS CRITICAL COMPONENTS IN LIFE SUPPORT
DEVICES OR SYSTEMS WITHOUT THE EXPRESS WRITTEN APPROVAL OF THE PRESIDENT OF NATIONAL
SEMICONDUCTOR CORPORATION. As used herein:
1. Life support devices or systems are devices or
systems which, (a) are intended for surgical implant
into the body, or (b) support or sustain life, and whose
failure to perform, when properly used in accordance
with instructions for use provided in the labeling, can
be reasonably expected to result in a significant injury
to the user.
National Semiconductor
Corporation
1111 West Bardin Road
Arlington, TX 76017
Tel: 1(800) 272-9959
Fax: 1(800) 737-7018
2. A critical component is any component of a life
support device or system whose failure to perform can
be reasonably expected to cause the failure of the life
support device or system, or to affect its safety or
effectiveness.
National Semiconductor
Europe
Fax: (a49) 0-180-530 85 86
Email: cnjwge @ tevm2.nsc.com
Deutsch Tel: (a49) 0-180-530 85 85
English Tel: (a49) 0-180-532 78 32
Fran3ais Tel: (a49) 0-180-532 93 58
Italiano Tel: (a49) 0-180-534 16 80
National Semiconductor
Hong Kong Ltd.
13th Floor, Straight Block,
Ocean Centre, 5 Canton Rd.
Tsimshatsui, Kowloon
Hong Kong
Tel: (852) 2737-1600
Fax: (852) 2736-9960
National Semiconductor
Japan Ltd.
Tel: 81-043-299-2309
Fax: 81-043-299-2408