PHIHONG PSF149-401

WWW.PHIHONG.COM
150 Watt Universal Industrial Series
PSF149 Quad-Output Enclosed Power Supply
Features
• Low Cost
• Enclosed Cover
• Power Factor Correction
• Low Profile Design
Applications
• Test Equipment
• Low Profile Racks
• Process Control
Safety Approvals Pending
• cUL 1950, 3rd Edition
• CE (Low Voltage Directive)
• Networking
• Business Machines
• TUV EN60950
Mechanical Characteristics
Dimensions:Length: 201.4+/-0.1mm (7.93in)
Width: 99.4+/-0.1mm (3.91in)
Height: 39.1+/-0.1mm (1.54in)
Weight: 0.9kg (1.98lb.)
Output Specifications
Model
DC Outputs
Voltage
PSF149-401
5V
-5V
-12V
+12V
Load
Min.
3A
0.2A
0.2A
1A
Ripple and
Regulation
Conv.
Max.(30cfm)
Noise
Line
Load
9A
0.6A
0.6A
3A
15A
1A
1A
5A
50mV p-p
100mV p-p
100mV p-p
100mV p-p
1%
2%
2%
2%
+5%
+6%
+6%
+6%
Phihong is not responsible for any errors or changes. Please contact the factory and visit www.phihong.com for the most up-to-date specifications.
WWW.PHIHONG.COM
PSF149 Characteristics
ENVIRONMENTAL:
Operation Temperature
0 to 50˚C
Storage Temperature
-25˚C to +85˚C
Humidity
20 to 90%
Emissions
FCC Class A
EN 55022 Class A
Immunity
ESD
EN61000-4-2: Level 3
RS
EN61000-4-3: Level 2
FET/Burst EN61000-4-4: Level 2
Surge
EN61000-4-5: (L-G) Level 3
(L-N) Level 2
CS
EN61000-4-6: Level 2
DIP
EN61000-4-11
Harmonic EN61000-3-2 Class D
Flicker
EN61000-3-3
POWER SUPPLY
INPUT:
AC Input Voltage Rating
100 to 240VAC
AC Input Voltage Range
90 to 264VAC
AC Input Frequency
47 to 63Hz
Input Surge Current
60A max.@cold start for 230VAC
Input Current
4A max.
OUTPUT:
Efficiency
70% min.@115VAC and max. load
Hold-up Time
16mS min.@120VAC and max.
Load
Power Factor Correction
>0.9@max. load
Overvoltage Protection
6.8V max. for +5V
Overcurrent Protection
All outputs equipped with short
circuit protection
GENERAL:
Dielectric Withstand (HIPOT) Test
Primary to secondary: 3000VAC 10mA
1 min.@without U-CASE
MTBF (Full load, 25˚C)
50K Hrs min. at max. load
25˚C ambient temperature
Dimension Diagram Unit: mm (inch)
PSF149/0312