PHIHONG PSAA18U-240

WWW.PHIHONG.COM
18 Watt Universal 3-Wire Input Adapter
PSAA18U Adapter Meets EISA and ENERGY STAR Requirements
preliminary
Features
•
•
•
Low Cost
Efficiency Level V Compliance
Class B EMI
•
•
Non-vented/Spill-proof Case
Low Profile Design
•
•
Peripherals
Network Hubs
•
IEC60950-1
Applications
•
•
Portable Equipment
Access Devices
Safety Approvals (Pending)
•
•
cUL/UL60950-1
CE
Mechanical Characteristics
•
•
•
•
Length: 103mm (4.06in)
Width: 49mm (1.93in)
Height: 33.5mm (1.32in)
Weight: 140g (4.94oz.)
Output Specifications
Load
Regulation
Model
DC Output
Voltage
Min.
Max.
Ripple (1)
P-P (max.)
PSAA18U-090
+9V
0A
2.0A
90mV
±5%
PSAA18U-120
+12V
0A
1.5A
120mV
±5%
PSAA18U-240
+24V
0A
0.75A
240mV
±5%
Line
Load
Efficiency
Level
(1) Measured with using 12-inch twisted pair terminated with a 10uF capacitor and 0.1uF ceramic in parallel.
Phihong reserves the right to make changes without further notice. Please consult Phihong USA and visit
www.phihong.com for the most up-to-date specifications.
PSAA18U Series Characteristics
INPUT:
AC Input Voltage Rating
100 to 240VAC
AC Input Voltage Range
WWW.PHIHONG.COM
Short-Circuit Protection
Output can be shorted permanently without damage
90 to 264VAC
ENVIRONMENTAL
Temperature
AC Input Frequency
Operation
Non-operation
47 to 63Hz
0 to +40°C
-20 to +70°C
Relative Humidity
Input Current
0.6A (rms) max. @ 100VAC
0.3A (rms) max. @ 240VAC
Leakage Current
0.25mA max. @ 250VAC / 50Hz.
Inrush Current (cold start @ ambient 25°C)
60A for 100VAC at max. load
150A for 240VAC at max. load
Input Power Saving
0.3W maximum at no load
OUTPUT:
Efficiency
≥ 80% average efficiency
Operation
Non-operation
0 to 90% Non-Condensing
0 to 95% Non-Condensing
Emissions
FCC Class B
EN55022 Class B / CISPR22 Class B
Immunity
EN 50082-1: (EN55024)
EN 61000-4-2, Level 4
EN 61000-4-3, Level 2
EN 61000-4-4, Level 2
EN 61000-4-5, Level 3
EN 61000-4-6, Level 2
EN 61000-4-8, Level 1
EN 61000-4-11
Dielectric Withstand (Hi-pot) Test
10mS Min. @ 115VAC / 60 Hz
Primary to Secondary: 3000VAC for 1 minute, 10mA
Primary to FG: 1500VAC for 1 minute, 10mA
Over-Voltage Protection
DC Output Connector
Hold-up Time
Auto restart
Over-Current Protection
Auto restart
Dimension Diagram Unit: mm
2.1mm x 5.5mm center positive standard