POWERBOX SM6000

LABORATORY
SM 6000 Series
6 0 0 0 W A T T S P R O G R A M M A B L E D C S U P P LY
Features
•
•
•
•
•
•
•
Constant voltage and constant current operation
Parallel operation master/slave
EMC standard EN61204-3
CE marked
Optional ethernet, RS232, IEEE 488 programming
IEEE 488 programming option
Ethernet, RS232 option
Specifications
OPERATING
INPUT
Efficiency
87%–91%
Switching frequency
100kHz
Thermal protection
Yes
20A (electronic limit)
Programming
I/P to O/P: 3750V rms (8mm creepage),
I/P – Case: 2500V rms, O/P – Case: 600VDC
Analogue Programming of voltage and current by
0-5V.
Programming speed
See table
Master/Slave operation
Parallel and series operation with equal current
and voltage sharing. In this way two or more SMunits can together be used as one high power
unit. Voltage and current of the units is controlled
by the master (by potentiometers or by
programming). Series operation up to 600V
Input voltage
342-457Vac 3 phase
Frequency
48Hz–62Hz
Inrush current
Isolation
OUTPUT
Output voltage
See table.
Output voltage adjustment
0%–100%
Output current
See table.
Output current adjustment
0%–100%
Metering
Digital meters standard
Resolution
0.03% voltage and current control with 10 turn
potentiometers.
Indicators
CV/CC mode, OVP triggered LEDs
Temperature coefficient
CV: 35x10-6 /°C, CC: 60x10-6 /°C
Load regulation
0%–100% load see table
Line regulation
Line ±10% – see table
The CV/CC regulated power supplies are very suitable for battery charging.
Ask for the special datasheet “BATTERY CHARGING WITH SM-series POWER
SUPPLIES”. This datasheet contains information about protective measures
against accidental battery reversing.
Ripple & Noise
See table.
ENVIRONMENTAL
Operating temperature
-20°C to 50°C
SM15-400: < 0.5mΩ; < 2.3mΩ
SM30-200: < 1.2mΩ; < 5mΩ
SM45-140: < 1.7mΩ; < 10mΩ
SM60-100: < 1.5mΩ; < 12mΩ
SM70-90: < 1.8mΩ; < 12mΩ
SM120-50: < 11mΩ; < 90mΩ
SM300-20: < 34mΩ; < 330mΩ
Cooling
Low noise blower, fan speed adapts to
temperature of internal heatsink. (from left to
right).
(50%–100% load step): 100µS; 120µS for
SM 15-400.
Stability
CV: 5x10 , CC: 10x10
Output impedance
(0-1kHz; 1-100kHz)
Recovery time
Remote sense
BATTERY CHARGING
-5
-5
2V max. per lead compensation.
STANDARDS AND APPROVALS
Safety standards
EN60950 / EN61010
EMC standards
EN61204-3, EN61000-6-2
EMI standards
EN61000-6-3 (EN55022B)
MECHANICAL
Mounting
470
Bench or 19" rack mounting
LABORATORY
SM 6000 Series
6 0 0 0 W A T T S P R O G R A M M A B L E D C S U P P LY
Selection Table
OUTPUT
VOLTAGE
(0V TO)
OUTPUT
CURRENT
(0A TO)
SM15-400
15V
400A
8mV pk-pk
300mA pk-pk
3.3mS
2.5mV
24mA
0.2mV
4mA
SM30-200
30V
200A
8mV pk-pk
60mA pk-pk
6.4mS
5mV
12mA
0.5mV
2mA
SM45-140
45V
140A
10mV pk-pk
25mA pk-pk
2.7mS
5mV
9mA
1mV
1.5mA
SM60-100
60V
100A
10mV pk-pk
10mA pk-pk
5.4mS
5mV
6mA
2mV
1mA
SM70-90
70V
90A
10mV pk-pk
10mA pk-pk
6.8mS
5mV
5mA
2mV
1mA
SM120-50
120V
50A
25mV pk-pk
10mA pk-pk
5.1mS
8mV
3mA
2mV
0.5mA
SM300-20
300V
20A
50mV pk-pk
5mA pk-pk
8.5mS
15mV
1.2mA
3mV
0.2mA
MODEL
NUMBER
RIPPLE & NOISE
CV
CC
PROGRAMMING
SPEED
LOAD REG.
0%–100%
CV
CC
LINE REG.
200–264VAC
CV
CC
OPTIONS
Screwdriver adjustment - option P001
Master / slave operation
Battery charging
SM45-140: P151, SM120-50: P152, SM300-20: P153
Increased max. output voltage / current - option P069
Enforced secondary isolation 1000V - option P089
High speed programming - SM15-400: P166, SM30-200: P167, SM45-140: P168,
SM60-100: P169, SM70-90: P170, SM120-50: P171, SM300-20: P172.
Built-in ISO AMP CARD for isolated analog programming - option P154
Built-in ethernet power supply controller - option P157
Built-in RS232 power suply controller - option P155
Built-in IEEE488 power supply controller - option P156
440 and 480 Vac input - option P165
Technical Illustrations
Your dependable power partner – www.powerbox.com.au