POWER-ONE YEV09T03-RG

YEV09T03 3A DC-DC POL Converter
4.5V to 13.8V Input  0.59V to 5.1V Output
Data Sheet
Member of the
Applications
 Low voltage, high density systems with
Intermediate Bus Architectures (IBA)
 Point-of-load regulators for high performance
DSP, FPGA, ASIC, and microprocessors
 Desktops, servers, and portable computing
 Broadband, networking, optical, and
communications systems
Benefits
 One part that covers many applications
 Reduces board space, system cost and
complexity, and time to market
Family
Features
 RoHS lead free and lead-solder-exempt products are
available
 Wide operating temperature range: 0 to 70 ºC;
optional to a range of -40 to 85 ºC
 High efficiency synchronous buck topology
 Low noise fixed frequency operation
 Wide input voltage range: 4.5V–13.8V
 High continuous output current: 3A
 Programmable output voltage range: 0.59V–5.1V
 Overcurrent, and short circuit protections with
automatic restart
 Enable input
 Start up into prebiased load
 No minimum load requirements
 High MTBF of 67 million hours
 Industry standard size through-hole single-in-line
package and pinout
 0.41”x0.40” (10.4mm x 10.16mm)
 Low height of 0.65” (16.51mm)
 UL94 V-0 flammability rating
 UL60950, CSA C22.2 No. 60950-00, and TUV
EN60950-1:2001
Description
The YEV09T03, non-isolated DC-DC point of load (POL) converter, delivers up to 3A of output current in an
industry-standard single-in-line (SIP) through-hole package. The YEV09T03 POL converter is an ideal choice for
Intermediate Bus Architectures where point of load conversion is a requirement. Operating from a 4.5-13.8V input
the POL converter provides an extremely tightly regulated programmable output voltage of 0.59 V to 5.1V. The
POL converter offers exceptional thermal performance, even in high temperature environments with minimal
airflow. This performance is accomplished through the use of advanced circuit solutions, packaging and
processing techniques. The resulting design possesses ultra-high efficiency, excellent thermal management, and
a slim body profile that minimizes impedance to system airflow, thus enhancing cooling for both upstream and
downstream devices. The use of automation for assembly, coupled with advanced power electronics and thermal
design, results in a product with extremely high reliability.
ZD-01968 Rev 1.1, 25-Mar-09
www.power-one.com
Page 1 of 10
YEV09T03 3A DC-DC POL Converter
4.5V to 13.8V Input  0.59V to 5.1V Output
Data Sheet
1.
Ordering Information
YE
V
09
T
03
–
0
z
Product
Family
Profile
Input
Voltage
PCB
Mounting
Output
Current
Dash
Options
RoHS Compliance
4.5V to
13.8V
Throughhole
0 – 0 to 70 °C
operating range.
R – -40 to 85 °C
operating range.
No suffix - RoHS compliant
with Pb solder exemption1
G - RoHS compliant for all six
substances
POL
Converter
Vertical
3A
______________________________________
1
The solder exemption refers to all the restricted materials except lead in solder. These materials are Cadmium (Cd), Hexavalent chromium
(Cr6+), Mercury (Hg), Polybrominated biphenyls (PBB), Polybrominated diphenylethers (PBDE), and Lead (Pb) used anywhere except in
solder.
Example: YEV09T03-0G: YEV09T03 POL converter with the commercial temperature range and lead-free
solder. Refer to Figure 1 for label marking information.
Figure 1. Label Drawing
2.
Absolute Maximum Ratings
Stresses in excess of the absolute maximum ratings may cause performance degradation, adversely affect longterm reliability, and cause permanent damage to the converter.
Parameter
Conditions/Description
Min
Max
Units
Input Voltage
Continuous
-0.3
15
VDC
Ambient Temperature Range
Operating (-R option)
-40
85
C
-55
125
C
Storage Temperature (Ts)
3.
Environmental and Mechanical Specifications
Parameter
Conditions/Description
Min
Nom
Weight
MTBF
Calculated Per Telcordia Technologies SR-332,
Method I Case 1, 50% electrical stress,
40°C ambient temperature
Lead Plating
YEV09T03-x and YEV09T03-xG
ZD-01968 Rev 1.1, 25-Mar-09
www.power-one.com
Max
Units
2.5
grams
67
MHrs
100% Matte Tin
Page 2 of 10
YEV09T03 3A DC-DC POL Converter
4.5V to 13.8V Input  0.59V to 5.1V Output
Data Sheet
4.
Electrical Specifications
Specifications apply at the input voltage from 4.5V to 13.8V, output load from 0 to 3A, output voltage from 0.59V to
5.1V, 22µF external output capacitor, and ambient temperature from -40°C to 85°C unless otherwise noted.
4.1
Input Specifications
Parameter
Conditions/Description
Min
Nom
Max
Units
Input voltage (VIN)
0.59V ≤ VOUT ≤ 3.63V
3.64V ≤ VOUT ≤ 5.1V
4.5
6.5
12
12
13.8
13.8
VDC
Input Voltage Ramping Up
4.1
4.3
4.5
VDC
Input Voltage Ramping Down
3.9
4.1
4.3
VDC
Undervoltage Lockout Turn On
Threshold
Undervoltage Lockout Turn Off
Threshold
Standby Input Current
VIN=12V, POL is disabled via ON/OFF
20
mADC
Input Reflected Ripple Current
Peak-to-Peak
BW=5MHz to 20MHz, LSOURCE=1µH,
See Figure 14 for setup
60
mA
4.2
Output Specifications
Parameter
Conditions/Description
Min
Output Voltage Range (VOUT)
Programmable with a resistor between
TRIM and GND pins
Output Voltage Setpoint Accuracy,
VOUT≥1V
Output Voltage Setpoint Accuracy,
VOUT<1V
VIN=12V, IOUT=IOUT MAX,
0.1% trim resistor, room temperature
VIN=12V, IOUT=IOUT MAX,
0.1% trim resistor, room temperature
Line Regulation, VOUT≥2.5V
VIN MIN to VIN MAX
0.5
%VOUT
Load Regulation, VOUT≥2.5V
0 to IOUT MAX
0.4
%VOUT
Line Regulation, VOUT<2.5V
VIN MIN to VIN MAX
5
mVDC
Load Regulation, VOUT<2.5V
0 to IOUT MAX
5
mVDC
Output Voltage Regulation
Output Voltage Peak-to-Peak
Ripple and Noise, BW=20MHz,
Full Load
Over operating input voltage, resistive
load, and temperature conditions until
the end of life
VIN=12V, VOUT=0.9V
VIN=12V, VOUT=2.5V
VIN=12V, VOUT=3.3V
VIN=12V, VOUT=5.0V
Nom
Max
Units
0.59
5.1
VDC
-1.0
1.0
%VOUT
-10
10
mVDC
-2.0
Dynamic Regulation
Peak Deviation
Settling Time
VIN=12V,
40 - 80% load step, Slew rate 1A/s,
to 1% of VOUT
45
25
Efficiency
VIN=12V
Full Load
Room temperature
VOUT=0.9V
VOUT=1.2V
VOUT=1.5V
VOUT=1.8V
VOUT=2.5V
VOUT=3.3V
VOUT=5.0V
75
80
84
85
88
90
93
www.power-one.com
Page 3 of 10
ZD-01968 Rev 1.1, 25-Mar-09
2.0
%VOUT
25
30
40
60
mV
mV
mV
mV
250
50
mV
s
%
%
%
%
%
%
%
YEV09T03 3A DC-DC POL Converter
4.5V to 13.8V Input  0.59V to 5.1V Output
Data Sheet
Parameter
Conditions/Description
Min
Switching Frequency
Max
560
Output Current (IOUT)
VIN MIN to VIN MAX
Output Current Derating
TAMB≤70°C
1
Nom
0
Units
kHz
3
ADC
3
ADC
Turn-On Delay Time
POL is Enabled
ON/OFF pin is pulled high
From VIN=VIN MIN to VOUT=0.1*VOUT.SET
0.3
1
ms
Turn-On Delay Time1
POL is Disabled
VIN=12V
From ON/OFF pin changing its state
from low to high until VOUT=0.1*VOUT.SET
0.3
1
ms
Rise Time1
COUT=0 µF, Resistive Load
From VOUT=0.1*VOUT.SET to
VOUT=0.9*VOUT.SET
1.2
3
ms
Admissible Output Capacitance
IOUT=IOUT MAX, Resistive load, ESR>1mΩ
1,140
µF
Max
Units
__________________________
1
Total start-up time is the sum of the turn-on delay time and the rise time
4.3
Protection Specifications
Parameter
Conditions/Description
Min
Nom
Output Overcurrent Protection
Type
Auto-Restart
Inception Point
Output Short Circuit
Current (RMS value)
4.4
105
150
ROUT<0.01Ω
%IOUT
1
A
Feature Specifications
Parameter
Conditions/Description
Min
Nom
Max
Units
Enable (ON/OFF pin)
Positive (enables the output
when ON/OFF pin is open or
pulled high)
ON/OFF Logic
ON/OFF High Input Voltage
POL is ON
ON/OFF High Input Current
POL is ON
ON/OFF Low Input Voltage
POL is OFF
ON/OFF Low Input Current
POL is OFF
ZD-01968 Rev 1.1, 25-Mar-09
www.power-one.com
2.4
-0.3
Page 4 of 10
N/A
5.5
VDC
1.0
mADC
0.4
VDC
0.55
mADC
YEV09T03 3A DC-DC POL Converter
4.5V to 13.8V Input  0.59V to 5.1V Output
Data Sheet
5.
5.1
Typical Performance Characteristics
95
Efficiency Curves (Room Temperature)
90
85
Efficiency, %
80
Efficiency, %
75
70
65
85
80
75
70
60
Vin = 10V
55
Vin = 12V
Vin = 13.8V
65
50
Vin = 10V
Vin = 12V
0.0
Vin = 13.8V
0.5
1.0
1.5
2.0
2.5
3.0
Output Current, A
45
0.0
0.5
1.0
1.5
2.0
2.5
3.0
Figure 4. Efficiency vs. Load. Vout=3.3V
Output Current, A
5.2
Figure 2. Efficiency vs. Load. Vout=1.2V
Turn-On Characteristics
90
Efficiency, %
85
80
75
70
65
Vin = 10V
Vin = 12V
Vin = 13.8V
60
0.0
0.5
1.0
1.5
2.0
2.5
3.0
Output Current, A
Figure 3. Efficiency vs. Load. Vout=2.5
Figure 5. Typical Start-Up Using Remote On/Off
(Vo = 1.2 Vdc, Io=3A). Ch1 – Vout, Ch2 – ON/OFF,
Ch3 - Iout
ZD-01968 Rev 1.1, 25-Mar-09
www.power-one.com
Page 5 of 10
YEV09T03 3A DC-DC POL Converter
4.5V to 13.8V Input  0.59V to 5.1V Output
Data Sheet
Figure 6. Typical Start-Up Using Remote On/Off
(Vo = 3.3 Vdc, Io=3A). Ch1 – Vout, Ch2 – ON/OFF,
Ch3 - Iout
Figure 8. Typical Start-Up with application of Vin
(Vo = 3.3Vdc, Io = 3A). Ch1 – Vout, Ch3 – Iout, Ch4 –
Vin,
5.3
Transient Response
Figure 7. Typical Start-Up with application of Vin
(Vo = 1.2Vdc, Io = 3A). Ch1 – Vout, Ch3 – Iout, Ch4
– Vin.
Figure 9. Transient Response to Dynamic Load Change from
40% to 80% of full load (Vin=12V, Vo=1.2Vdc). Ch3 –
Iout. Scale=0.2A/mVΩ
ZD-01968 Rev 1.1, 25-Mar-09
www.power-one.com
Page 6 of 10
YEV09T03 3A DC-DC POL Converter
4.5V to 13.8V Input  0.59V to 5.1V Output
Data Sheet
6.
Application Information
6.1
Figure 10.
Transient Response to Dynamic Load Change
from 40% to 80% of full load (Vin=12V,
Vo=2.5Vdc). Ch3 – Iout. Scale=0.2A/mVΩ
Input and Output Impedance
The POL converter should be connected to the DC
power source via low impedance.
In many
applications, the inductance associated with the
distribution from the power source to the input of the
converter can affect the stability of the converter.
Internally, the converter includes 4.7μF (low ESR
ceramics) of input capacitance which eliminates the
need for external input capacitance. However, if the
distribution of the input voltage to the POL converter
contains high inductance, it is recommended to add
a 100μF decoupling capacitor placed as close as
possible to the converter input pins. A low-ESR
tantalum or POS capacitor connected across the
input pins help ensuring stability of the POL
converter and reduce input ripple voltage.
A 22μF ceramic output capacitor is recommended to
improve output ripple and dynamic response.
It is important to keep low resistance and low
inductance of PCB traces for connecting load to the
output pins of the converter in order to maintain good
load regulation.
6.2
Output Voltage Programming
The output voltage can be programmed from 0.59V
to 5.1V by connecting an external resistor RTRIM
between TRIM pin (Pin 5) and GND pin (Pin 3), as
shown in Figure 12.
YEV09T03
2
4
VIN
VOUT
ON/OFF
TRIM
1
5
Rload
R TRIM
Figure 11.
Transient Response to Dynamic Load Change
from 40% to 80% of full load (Vin=12V,
Vo=3.3Vdc). Ch3 – Iout. Scale=0.2A/mVΩ
3
GND
Figure 12. Programming Output Voltage With A Resistor
The trim resistor RTRIM for a desired output voltage
can be calculated using the following equation:
RTRIM 
ZD-01968 Rev 1.1, 25-Mar-09
www.power-one.com
1.182
, kΩ
VOUT  0.591
Page 7 of 10
YEV09T03 3A DC-DC POL Converter
4.5V to 13.8V Input  0.59V to 5.1V Output
Data Sheet
6.4
where:
VOUT = Desired (trimmed) value of output voltage V
RTRIM = Required value of the trim resistor in kΩ
If the RTRIM is not used, the output voltage of the POL
converter will be 0.591V.
Note that the trim resistor tolerance directly affects
the output voltage accuracy. It is recommended to
use ±0.1% trim resistors to meet the output voltage
setpoint accuracy specified in p. 4.2.
Table 1. Trim Resistor Values
6.3
V0UT, V
Calculated
RTRIM, kΩ
Standard Value of
0.1% Resistor, kΩ
0.8
1.2
1.5
1.8
2.5
3.3
5.0
5.65
1.94
1.3
0.98
0.62
0.44
0.27
5.62
1.93
1.30
0.976
0.619
0.437
0.267
6.4.1
Input Undervoltage Lockout
The POL converter will shut down when the input
voltage drops below a predetermined voltage. It will
start automatically when the input voltage exceeds
the specified threshold.
6.4.2
Output Overcurrent Protection
The POL converter is protected against overcurrent
and short circuit conditions.
Upon sensing an
overcurrent condition, the POL converter will enter
hiccup mode of operation. Once the overload or
short circuit condition is removed, the POL converter
will automatically restart and Vout will return to its
nominal value.
7.
7.1
The ON/OFF pin should be controlled with an open
collector transistor as shown in Figure 13.
1
VIN
ON /OFF
YEV09T03
Internal
Enable
Circuit
VOUT
4
TRIM
5
Rload
CONTROL
INPUT
4.32kΩ
3
Ripple and Noise
1 H
The ON/OFF pin is used to turn the POL converter
ON or OFF remotely by a signal from a system
controller. For positive logic, the POL converter is
ON when the ON/OFF pin is at a logic high (2.4V
min) or left open. The POL converter is OFF when
the ON/OFF pin is at a logic low (0.4V max) or
connected to GND.
2
Characterization
The output voltage ripple and input reflected ripple
current waveforms are measured using the test
setup shown in Figure 14.
ON/OFF (Pin 1)
INPUT
VOLTAGE
Protections
RTRIM
GND
Figure 13. Circuit Configuration For ON/OFF Function
V source
CIN
100 F
tantalum
+2x10 F
ceramic
YEV09T03
DC/DC
Converter
22 F
ceramic
capacitor
Vout
Figure 14. Test Setup For Measuring Input Reflected-Ripple
Current And Output Voltage Ripple
8.
Safety
The YEV09T03 POL converters do not provide
isolation from input to output. The input devices
powering YEV09T03 must provide relevant isolation
requirements according to all IEC60950 based
standards. Nevertheless, if the system using the
converter needs to receive safety agency approval,
certain rules must be followed in the design of the
system. In particular, all of the creepage and
clearance requirements of the end-use safety
requirements must be observed.
These
requirements are included in UL60950 - CSA6095000 and EN60950, although specific applications may
have other or additional requirements.
The YEV09T03 POL converters have no internal
fuse. If required, the external fuse needs to be
ZD-01968 Rev 1.1, 25-Mar-09
www.power-one.com
Page 8 of 10
YEV09T03 3A DC-DC POL Converter
4.5V to 13.8V Input  0.59V to 5.1V Output
Data Sheet
provided to protect the converter from catastrophic
failure. Refer to the “Input Fuse Selection for DC/DC
converters” application note on www.power-one.com
for proper selection of the input fuse. Both input
traces and the chassis ground trace (if applicable)
must be capable of conducting a current of 1.5 times
the value of the fuse without opening.
To comply with safety agencies’ requirements, a
recognized fuse must be used in series with the input
line. The fuse must not be placed in the grounded
input line. Abnormal and component failure tests
9.
were conducted with the POL input protected by a
fast-acting 25A fuse. If a fuse rated greater than 25A
is used, additional testing may be required.
The maximum DC voltage between any two pins is
Vin under all operating conditions. In order for the
output of the YEV09T03 POL converter to be
considered as SELV (Safety Extra Low Voltage),
according to all IEC60950 based standards, the input
to the POL needs to be supplied by an isolated
secondary source providing a SELV also.
Pin Assignments and Description
Pin
Name
Pin
Number
Pin
Type
Buffer
Type
Pin Description
Notes
ON/OFF
1
I
PU
Enable
Pull high to turn ON the POL
VIN
2
P
Input Voltage
GND
3
P
Power Ground
VOUT
4
P
Output Voltage
TRIM
5
I
A
Output Voltage Trim
Connect a high accuracy resistor between TRIM
and GMD pins to set the output voltage
Legend: I=input, O=output, I/O=input/output, P=power, A=analog, PU=internal pull-up
ZD-01968 Rev 1.1, 25-Mar-09
www.power-one.com
Page 9 of 10
YEV09T03 3A DC-DC POL Converter
4.5V to 13.8V Input  0.59V to 5.1V Output
Data Sheet
10. Mechanical Drawings
All Dimensions are in inches
Tolerances:
X.XX: 0.02”
X.XXX: 0.01”
Figure 15. Mechanical Drawing
Figure 16. Recommended Footprint – Top View
Notes:
1. NUCLEAR AND MEDICAL APPLICATIONS - Power-One products are not designed, intended for use in, or authorized for use as critical
components in life support systems, equipment used in hazardous environments, or nuclear control systems without the express written
consent of the respective divisional president of Power-One, Inc.
2. TECHNICAL REVISIONS - The appearance of products, including safety agency certifications pictured on labels, may change depending on
the date manufactured. Specifications are subject to change without notice.
ZD-01968 Rev 1.1, 25-Mar-09
www.power-one.com
Page 10 of 10